5
Galileo Rubidium Standard - Lifetime data and GIOVE-A related telemetries - Fabien Droz, Gérald Barmaverain, Qinghua Wang, Pascal Rochat Temex Neuchâtel Time SA  Neuchâtel, Suisse [email protected] Francesco Emma, Pierre Waller   European Space Agency (ESTEC) / Netherlands  Nordwijk, Netherlands Galileo navigation program is in progress under the technical supervision of the European Space Agency (ESA). The preliminary activities related to GSTB-V2 experimental satellites provide the first results and the implementation of the In Orbit Validation (IOV) phase are in progress. Atomic clocks represent critical equipment for the satellite navigation system and clocks development has been continuously supported by ESA. The Rubidium Atomic Frequency Standard (RAFS) and the Passive Hydrogen Maser (PHM) are at present the baseline clock technologies for the Galileo navigation payload. For the RAFS, initial ground technological project related to lifetime possible limitation of the clock was already initiated in 2001. Telemetries of the operating RAFS on board of GIOVE-A provide highly valuable data to compare with the ground data and validate the selected method of 2001. This article gives an overview on the ground lifetime data of the RAFS in comparison with GIOVE-A data. Extrapolation for the 12 years Galileo mission duration is also provided. I. I  NTRODUCTION GALILEO is a joint initiative of the European Commission and the European Space Agency (ESA) for a state-of-the-art global navigation satellite system, providing a highly accurate, guaranteed global positioning service under civilian control. It will probably be inter-operable with GPS and GLONASS, the two other Global Navigation Satellite Systems (GNSS) available today.  The fully deployed Galileo system consists of 30 satellites (27 operational and 3 active spares), stationed on three circular Medium Earth Orbits (MEO) at an altitude of 23 222 km with an inclination of 56º to the equator. Atomic clocks represent critical equipment for the satellite navigation system. The Rubidium Atomic Frequency Standard (RAFS) and Passive Hydrogen Maser (PHM) are at  present the baseline clock technologies for the Galileo navigation payload. According to the present baseline, every satellite will embark two RAFS' and two PHM's. The adoption of a "dual technology" for the on-board clocks is dictated by the need to insure a sufficient degree of reliability (technology diversity) and to comply with the Galileo lifetime requirement (12 years). Both developments are based on early studies performed at the Observatory of Neuchâtel (ON) from end of 1980s and Temex Neuchâtel Time (TNT) since 1995. These studies have been continuously supported  by Swiss fundings within ESA technological programs especially since the set-up of the European GNSS2 program. The activities related to Galileo System Test Bed (GSTB- V2) experimental satellite as well as the implementation of the In Orbit Validation phase are in progress. The first experimental satellite (GIOVE-A) was launched 28 th  December 2005, to secure the Galileo frequency fillings, to test some of the critical technologies, such as the atomic clocks, to make experimentation on Galileo signals and to characterise the MEO environment. There is two RAFS on the GIOVE-A satellite supplied by Surrey Satellite Technologies Ltd. II. DEVELOPMENT & QUALIFICATION ACTIVITIES OF R UBIDIUM ATOMIC FREQUENCY STANDARD The RAFS development milestones are chronologically listed as below: The first development activity kicked off at TNT in 1997, and completed in 2000 with one Engineering Model (EM) RAFS  produced. The updated RAFS development started in June 2000 and completed at the beginning of 2002. The industrial consortium is led by TNT with Astrium Germany as the subcontractor for the electronics package. The results of this development is applied clock design used for qualification and lifetime testing. The last development and qualifications step was initiated at the end of 2001 and completed at the beginning of 2003 with the delivery of an EM, which is the baseline unit for the development of the flight models for GSTB-V2. The main contribution of this last development step is the Inclusion of a DC/DC converter and the satellite TT&C interface compatible with ESA's new requirements. It doesn’t affect the lifetime sensitive parameters of the clock.

Galileo Rubidium Standard - Lifetime data and GIOVE-A related telemetries -

  • Upload
    n467rx

  • View
    222

  • Download
    0

Embed Size (px)

Citation preview

8/14/2019 Galileo Rubidium Standard - Lifetime data and GIOVE-A related telemetries -

http://slidepdf.com/reader/full/galileo-rubidium-standard-lifetime-data-and-giove-a-related-telemetries- 1/5

8/14/2019 Galileo Rubidium Standard - Lifetime data and GIOVE-A related telemetries -

http://slidepdf.com/reader/full/galileo-rubidium-standard-lifetime-data-and-giove-a-related-telemetries- 2/5

In the frame of GSTB-V2, one EQM, one Proto-FlightModel (PFM) and five Flight Model (FM) units have beendelivered. The PFM and FM1 are integrated in GIOVE-B andready for launch. The FM4 and FM5 are integrated in GIOVE-

A and in orbit since 28

th

December 2005. In addition, the FM2and FM3 are available as FM spare units.

RAFS for GSTB-V2 performance achieved are given in the

table 1 and the plot in figure 1.

Table 1: RAFS GSTB-V2 general performance achieved

Figure 1. RAFS GSTB-V2 Allan deviation (ground measurements)

Figure 2. Picture of the GSTB-V2 RAFS

The detailed description of these units was published in previous EFTF paper [1].

III.  LIFETIME EXTRAPOLATION FROM GROUND TESTING 

In the frame of the “Lifetime Qualification of RubidiumClock”, five RAFS EQM’s were manufactured and testedunder vacuum in order to perform the monitoring of the

 potential lifetime limitations of the RAFS.

The test bench is composed of five identical units andsome common elements.

The five identical units are composed of:

•  the vacuum chamber with pumping system and gauge

•  the cooled base-plate

•  the frequency measurement system (including PC)

•  the TM output terminals

The common elements are:

  the reference frequency system; H-Maser with GPSmonitoring and the frequency distribution unit (common for all the TNT facilities).

•  the frequency measurements instruments; five Picotimeinstruments measure independently each unit.

•  the automatic TM measurement system; parameters with possible ageing are monitored.

•  the power supply; five RAFS are connected on two 12V batteries in serie

•  The cooling system; the five cooled base-plate areconnected in serie

The overall layout of the test bench are illustrated below.Most of the parts are of-the-shelf standard parts.

Figure 3. The five vacuum chambers used for lifetime test.

From the validation of the test bench and the tuning of the 5

RAFS EQM’s, a total period of about 12 months of testing/adjustment was performed. Then, a first period of one

year of continuous measurement was performed. At the end

of this first year of measurement, the units were dismounted

Parameter   Measurement 

Frequency stability  < 4*10-14 @ 10’000 sec 

Flicker floor   < 3*10-14 (drift removed) 

Thermal sensitivity  < 5*10-14 /°C 

Magnetic sensitivity  < 1*10-13 / Gauss 

Mass and volume  3.3 kg and 2.4 liter  

1.0E-14

1.0E-13

1.0E-12

1.0E-11

1 10 100 1000 10000

Averaging time, T, in seconds

   A   l   l  a  n   d  e  v   i  a   t   i  o  n ,  s   i  g  m  a  y   (   T   )

RAFS Spec.

PFM (GIOVE-B)

FM1 (GIOVE-B)

FM2 (Spare)

FM3 (Spare)

FM4 (GIOVE-A)

FM5 (GIOVE-A)

Frequency stability of GSTB-V2 RAFS (Q4 2005) drift removed

8/14/2019 Galileo Rubidium Standard - Lifetime data and GIOVE-A related telemetries -

http://slidepdf.com/reader/full/galileo-rubidium-standard-lifetime-data-and-giove-a-related-telemetries- 3/5

and inspected. Then, the five re-assembled RAFS were

submitted to the second year of continuous operation with

 parameters monitoring.

In total six parameters were measured:- Output Frequency

- Rb spectral lamp light intensity emission- Rb atomic response signal level

- Crystal control voltage

- Regulated internal reference voltage

- Interrogation power injected in micro-wave cell

Three typical records are shown in figure x to y.

Figure 4. One year spectral lamp light intensity monitoring on “lifetime”

EQM5

Figure 5. One year Rb atomic response signal monitoring on “lifetime”

EQM5

Figure 6. 1 years 10 MHz output frequency measurement on “lifetime”

EQM5

Based on the records, an extrapolation for 12 years was

 performed. Different fittings were evaluated to generate theextrapolation formula.

For the Rb spectral lamp light intensity and the Rb atomic

signal level the best fitting corresponds to a formula based on

square root of time and is the one used for the prediction table(see table x). This result was predictable considering that the

ageing effect on the lamp is related to the Rb diffusion in thesurrounding glass. This phenomena is well known and was

measured by several institutes with same results, in relationwith square root of time [2]. The prediction demonstrates that

no major impact on performances are foreseen for a lifetime

of 12 years.

An example of Rb spectral lamp light intensity extrapolationis illustrated in figure 8 (EQM5). The red curve is themeasurement data during one year, the black one is anexponential fitting curve, the blue one a linear fitting and the

 best fitting is the green curve in square root of time

3.10

3.08

3.06

3.04

3.02

3.00

2.98

   L   i  g   h   t

300x103

2001000

x1000 sec

light measplight_exp

plight_sqtplight_lin

Year exp sqt lin1 3.081 3 .081 3 .0811 .25 3 .079 3 .079 3 .0791. 5 3. 07 8 3 .07 7 3 .0 762 3.076 3 .074 3 .0712. 5 3. 07 5 3 .07 2 3 .0 673 3.074 3 .069 3 .0624 3.074 3 .065 3 .0525 3.074 3 .061 3 .0426 3.074 3 .057 3 .0337 3.074 3 .054 3 .0238 3.074 3 .051 3 .0149 3.074 3 .048 3 .00410 3. 074 3 .04 6 2 .9 9411 3. 074 3 .04 3 2 .9 8512 3. 074 3 .04 1 2 .9 75

 

Figure 7. Spectral lamp light intensity TM on “lifetime” EQM5 with

 prediction on 12 years

A strong correlation between the spectral lamp ageing and the

frequency drift is also clear. Papers were already publishedon this topic [3].

The table 2 provides the summary of these key parameters  predicted evolution using square root of time for the five

EQM units submitted to life testing.

Such extrapolation is corresponding to the law of Rb

absorption into the lamp walls.

Square root of time extrapolation on 12 years

EQM1 EQM2 EQM3 EQM4 EQM5

Freq -9.2E-10 +1.8E-10 -4.2E-10 -6.5E-10 -4.5E-10

Light -15% -18% -20% -11% -6%

Signal -11% -1% -7.5% -2% <-1%

Table 2: Extrapolation of ageing data on 12 years

IV.  GIOVE-A TM (JANUARY –OCTOBER 2006)

In order to verify the in-orbit RAFS ageing, as demonstrated

in the lifetime program, the main telemetries are related to the

spectral lamp light intensity level and the atomic signal level.

3.100

3.095

3.090

3.085

      L      i    g      h      t

25x103

20151050

x1000 sec

Square Root Fit:fit_light= W_coef[0]+W_coef[1]*x^0.5W_coef={3.097,-9.1714e-05}V_chisq= 2.32856e-05; V_npnts= 13433;W_sigma={4.19e-06,2.77e-08}

3.73

3.72

3.71

3.70

3.69

3.68

3.67

      S      i    g    n    a      l

25x103

20151050

Time ( * 1000s )

fit_signal= W_coef[0]+W_coef[1]*x^0.5W_coef={3.7048,1.353e-05}V_chisq= 0.716141; V_npnts= 13433;W_sigma={0.000734,4.87e-06}

-180x10-12

-160

-140

-120

-100

-80

-60

-40

-20

      F    r    e    q    u    e

    n    c    y

25x103

20151050

Time ( * 1000s )

Square Root Fit:fit_freq= W_coef[0]+W_coef[1]*x^0.5W_coef={-7.5687e-11,-6.2115e-13}V_chisq= 1.09772e-21; V_npnts= 13395;W_sigma={2.88e-14,1.91e-16}

8/14/2019 Galileo Rubidium Standard - Lifetime data and GIOVE-A related telemetries -

http://slidepdf.com/reader/full/galileo-rubidium-standard-lifetime-data-and-giove-a-related-telemetries- 4/5

The 10th January 2006, the RAFS FM4 was switched-on for 

the first time in orbit. The establishment of the internal TM

was exactly in agreement with the ones recorded duringlaboratory test.

Figure 8. Comparison of the stabilisation process of the critical TM during

the warm-up in orbit and on ground

Spectral Lamp Light Intensity TM

The spectral lamp light intensity level is collected through the

 photo-cell located inside the micro-wave assembly. When thelamp is switched-off, the reference level is 2.0V. The

saturation is at about 4.8V. In nominal operation, the FM4

level was set at about 3.5V.

After an OFF period, the micro-wave assembly is cold and

the vapor of Rb is at a very low density. By the way, no light

is absorbed and the photo-cell is saturated (4.8V). After about

one hour, the micro-wave assembly reaches its nominal

temperature and the photo-cell indicates the operational level

(about 3.5V).

In the figure below we observe several ON-OFF cyclesincluding a long OFF period between the day 100 and 140.

Figure 9. Spectral lamp light intensity TM from FM4 (GIOVE-A)

During the life of the clock, the spectral lamp lightintensity will slowly decay due to the Rb diffusion in thesurrounding glass. As observed during the lifetime test

  program, the decay of light intensity is a function whichfollow to the square root of time. The TM coming from the in-orbit FM4 is in line with the expectation coming out of thelifetime program. In addition, when the unit is OFF, theageing process stops and the next ON level is equal to the last

level in the previous ON period.It must be noted that the frequency drift of the RAFS is

nearly proportional to the decay of the light. So, the frequencydrift value decay with time for a better performance.

As illustrated in figure 9, the FM4 light TM measurementis affected by the digitalisation noise due to the A/D converter low resolution (8 bit resolution).

Figure 10. Zoom on Spectral lamp light intensity TM

Warm-up

 period after 

switch-off 

on-board data

0.00

1.00

2.00

3.00

4.00

5.00

6.00

08:15:00 08:30:00 08:45:00 09:00:00 09:15:00 09:30:00 09:45:00

Rb LIGHT

Rb SIGNAL

lab data

0.00

1.00

2.00

3.00

4.00

5.00

6.00

21:00:00 21:15:00 21:30:00 21:45:00 22:00:00 22:15:00 22:30:00

Rb LIGHT

Rb SIGNAL

8/14/2019 Galileo Rubidium Standard - Lifetime data and GIOVE-A related telemetries -

http://slidepdf.com/reader/full/galileo-rubidium-standard-lifetime-data-and-giove-a-related-telemetries- 5/5

Atomic Signal level TM 

After the warm-up period (about one hour), the lower isthe TM voltage, the higher is Atomic Signal level. When nosignal exists, the TM provides 5V. The value of 5V is

observed each time after a switch-off of several minutes (or more) as the density of the Rb vapor in the cell is too low tocollect a signal.

For the FM4, the signal is nominal at 2.5V. The smallageing variation of TM is due to a decay of the Atomic Signalrelated to the decay of the spectral lamp light intensity. Thislow decay have no visible effect on the frequency stability.

Figure 11. Atomic Signal TM from FM4 (GIOVE-A) 

The noise measured on the Atomic Signal is related to theripple of the analogue TM (+/-150 mV) and is nominal.

Here again, the in-orbit measurement results are similar tothe ground measurement results coming from the lifetime

 program.

V.  CONCLUSIONS: 

The lifetime program running on five reference units has provided useful results and demonstrated the capability of theRAFS to operate for 12 years under vacuum withoutsignificant degradation.

Based on the TM from January to October 2006, the RAFSFM4 operates according to the expectation.

The small ageing trend observed is in line with predictionof the lifetime program results and is compatible with Galileo12 years mission.

The numerous switch-on / switch-off sequences operatedon the RAFS FM4 have not affected the overall clock 

 behaviour.

The real environmental space conditions seem not to affect

the ageing behaviour in comparison with the simulated oneused for lifetime testing.

VI.  R EFERENCES 

[1]  F.Droz, P.Mosset, G.Barmaverain, P.Rochat, Q.Wang Temex  Neuchâtel Time SA; M.Belloni, L.Mattioni Galileo Avionica / Italy;U.Schmidt, T.Pike   EADS Astrium / Germany; F. Emma, P.Waller 

  European Space Agency (ESTEC) / Netherlands "The On-BoardGalileo Clocks: Rubidium Standard and Passive Hydrogen Maser  Current Status and Performance" 20th Europen Frequency and TimeForoum Braunschweig (D) March 27-30, 2006.

[2]  G.Mileti, H.Schweda, P.Thomann, G.Busca, Observatoire cantonal de

  Neuchâtel, C. Couplet, P.Rochat, Temex Neuchâtel Time SA;"Miniaturized Rubidiuim Clocks for Space and IndustrialApplications". International Frequency Control Symposium, IEEE1995

[3]  J. Camparo,   Photonics Technology Dept The Aerospace Corporation;"Frequency Equilibration and the Light-Shift Effect for Block IIR GPSRubidium Clock"; 36th Annual Precise Time and Time Interval (PTTI)Meeting. December 7-9, 2004