SEN Plus
SEN PlusLV Equipment
GE EnergyIndustrial Solutions
SEN Plus
IEC LV equipment
SEN PlusLV Equipment – Product Overview
Commercial market
Industrial market
CommercialLow Commercial High Commercial Low Industrial High Industrial
Cus
tom
er r
equi
rem
ents
SEV /SEK
SEN Plus
QuiXtra 630
Modula Plus
SEN PlusMarkets
Renewable EnergiesWind, Solar, Hydro, Incinerator Plants
Oil & GasOn & Off Shore Sites, DW-MD-UP Stream Applications
Commercial Retail, Banks, Office & Comm. Buildings, Hotels, Telecom, Datacenter
HealthcareHospital building,medical equipment
TransportationRailways, airports, tunnels, naval
WaterDesalination Plants, Municipalities
UtilitiesPower Generation, Nuclear,Gas turbines
Process Industry Chemicals, Paper, Automotive, Pharma, Steel, Cement
SEN PlusManufacturing plants
GE manufacturing plants
� Bielsko Biala, Poland
� Haaksbergen, Netherlands
� Johannesburg, South Africa
� Shanghai, China
� Bangalore, India (partially)
GE Business partner
� ~ 60 partner in EMEA in
25 different countries
� ~ 90 partner worldwide in
> 33 different countries
SEN Plus
SEN Plus with EntelliGuard TMG
SEN PlusProduct - Scope
Control CenterFixed, plug-in & withdrawable
Special solutions
Distribution board / feedersFixed & withdrawable appl.
ACB, MCCB & LBS
Empty Panel Full mounting plate
Customized solutions
Main Incomer & BuscouplerUp to 6400A
Fixed & withdrawable appl.
Fused feeder Panel Up to 630A – DIN & BS
HSE Plus switch
SEN PlusTechnical characteristics Electrical dataRated operational voltage Ue 690V AC / 600V DC
Rated frequence f 50 / 60Hz
Rated impulse voltage / Overvoltage category Uimp 8kV / III
Rated current horizontal busbars up to 7600A
Peak withstand current Ipk up to 220kA
Shorttime withstand current Icw up to 100kA
Rated current vertical busbars - Control Center Plug-in & Withdrawable up to 1900A
Fixed up to 2700A
Mechanical dataModularity 1 E = 25mm
Dimensions Height 2000 / 2200mm
Depth 600 / 800 / 1200mm
Width 400 up to 1200mm
Degree of protection IP30 up to IP54
Form of internal separation up to Form 4b
Color RAL 7035
Epoxy-Polyester
StandardsType tested IEC 61439-2, EN 60439-1
Internal arc tests IEC/TR 61641
Seisimic withstand UBC, IEEE 344
SEN PlusPanel dimensions 60
0
800
1200
Panel width:
PC – 400, 500, 600, 800, 1000, 1200
CC – 800, 1000, 1200
Panel height: 2000, 2200
Up to 2500A
Up to 4000A
Up to 7600A
SEN PlusSystem - Overview
DimensionsHeight: 2000/2200 mmDepth: 600/800/1200 mmWidth: 400/500/600/800/1000/1200 mm
Depth Current600 mm 3200 A800 mm 4000 A1200 mm 6400 A
• All widths available with 3 doorsor one large door
• Available in combination withEntelliGuard Air Circuit Breaker
400 mm - 1000 A - 1 or 2 ACB500 mm - 2000 A - 1 or 2 ACB600 mm - 2500 A - 1 or 2 ACB800 mm - 3200 A - 1 or 2 ACB
1000 mm - 6400 A - 1 ACB1200 mm - 6400 A - 1 ACB, 4 pole
7 / GEIS 10-2011
SEN Plus
DimensionsHeight: 2000/2200 mmDepth: 600/800/1200 mmWidth: 800/1000/1200 mm
Depth Current600 mm 3200 A800 mm 4000 A1200 mm 6400 A
• Cable compartment in different widths available• Module sizes from 2 to 36 E 1E=25 mm– Fixed modules– Plug-in modules– Fully withdrawable modules
Drawer compartment Cable compartmentBusbar compartment
8 / GEIS 10-2011
System - Overview
SEN PlusFrame & Enclosure
� Rigid frame construction
� rolled frame tubes
– high mechanical strength
- no sharp edges
� bolted self supporting structure
� use of self-tapping screws
� frame parts zinc-plated
� high modularity thru 25 mm grid dimension
� easy customization
� doors & covers 2mm sheet steel
– powder painted RAL 7035-
SEN PlusMain busbar system - Overview
Panel depth:600 mm 800 mm 1200 mm
BB position:
Top
Middle
Bottom
Rated current:up to 2500A up to 4000A up to 7600A
SEN Plus
Current Cross-SectionIcw 1sec
A mm kA
1000 50x10 50
1250 60x10 65
1600 80x10 80
2000 100x10 100
2500 2/80x10 100
3200 2/100x10 100
4000 3/100x10 100
5000 (2+3)/100x10 100
7600 (3+4)/100x10 100
Main busbar cross -sections
SEN PlusMain Distribution Board
� air circuit breakers MPACT / EntelliGuard TMG
� moulded case circuit breakers Record Plus
� load break switches DILOS
Standardized main- and sub distribution boards for currents up to 6400A optional equipped with:
SEN PlusPower Center with EntelliGuard TMG
� Incomers, feeders & buscouplers up to 6400A
� comprehensive trip unit providing full selectivity
� Profibus & Modbus communication capabilities
� More than 800 standard configurations
� Full verification by test according IEC 61 439 -
� Small footprint
� RELT (reduced energy let thru)
� 2 breaker per column up to 2500 A
� 3 separate or one big compartment door
� Form of internal separation up to form 4b
� Degree of protection up tp IP54
� Arc proof tests according IEC 61641
SEN PlusPanel deratingRated current frame W/D
kVA A kA
@ 400V @ 6% A size [mm] 35°C 50°C
630 914 15 1000 1 500/600 1000 1000
800 1200 19 1250 1 500/600 1250 1200
1000 1450 24 1600 1 500/600 1600
1000 1450 24 2000 1 500/600 1600
1250 1800 30 2000 1 500/600 1900
1250 1800 30 2500 2 600/600 1850
1600 2350 38 2500 2 600/600 2350
1600 2350 38 3200 2 800/800 2550
2000 2900 48 3200 2 800/800 2800
2000 2900 48 4000 2 1000/800 3600
2500 3600 60 4000 2 1000/800 3900 3600
3000 4350 72 5000 3 1000/1200 5000 4700
3600 5250 87 6300 3 1000/1200 6000 5400
4000 5800 96 6300 3 1000/1200 6000
ambient temperature
Transformer derating @
SEN PlusEntelliGuard TMGThree sizes cover all..
Envelope 1• Up to 2000A • Up to 1000V AC• Up to 750V DC• Up to 85kA
Envelope 2• Up to 4000A • Up to 1000V AC• Up to 750V DC• Up to 100kA
Envelope 3• Up to 6400A • Up to 1000V AC• Up to 750V DC• Up to 150kA
SEN Plus
� Broad setting Range. � Extremely accurate� Multiple Protection devices. � Tracks events.
� Standard... with Ammeter� Optional full measurement package
� Optional ‘intelligent’ protection devices.� Optional Relaying package.
� Communication via Modbus or Profibus
EntelliGuard TMGState of The Art Trip Units
SEN PlusRELT protection
� RELT (reduced energy let thru) safety function
� protection of service personnel
� EntelliGuardTMG automatically switches to lowest
short circuit setting when door open
SEN PlusDistribution boards with Record Plus :
� Feeders up to 1600A
� 2 MCCBs per cubicle possible
� Fully selective with main incomers
� Small footprint
� 3 separate or one big compartment door
� incoming from bottom or top
� Breaker 3 and 4 poles
� Form of internal separation up to form 4b
� Degre of protection up tp IP54
Resim şu anda görüntülenemiyor.
SEN Plus
�Fixed, plug-in and fully withdrawable version
� Internal separation up to form 4b
� Vertical busbar 3 & 4 pole from 850 to 1900 A
� Internal degree of protection - IP 20 (finger proof)
� Degree of protection of the enclosure up to IP54
� Motor starter-combinations up to 250 kW
� Feeders up to 800A
Control Center
SEN PlusFixed modules (old version):
� With MCCB Record Plus
� Use of pluggable MCCB to allow easy
breaker
removal
� Standard feeder & motor starter modules
� Reliable, bolted connection to vertical busbar
� Form of separation from form 2a up to form
4b
� Rotary handle or toggle behind the door
� Protection degrees - IP 30 and 54
SEN Plus
� very compact design
� significantly improved stacking density
� Up to 32x 160A functions in 1 column
� Vertical busbar in separate compartment leftside
� Currents up to 2700A
� simple & fast module assembly & wiring
� Form2 & 4 internal separation
� optional: IP 40 cover plate
� MCCB – vertical orientation possible
� full KEMA test reports
� new EfficorTM motor starter units
Control Center – Fixed application
SEN PlusFixed modules
�Feeder, 3 & 4 pole up to 630A
�Motor starter with fuseless protection Direct online
Reverse starter
Star / Delta starter
� Reliable, bolted connection to vertical busbar system
� Form of separation from form 2a up to form 4b
� Protection degrees - IP 30………IP54
SEN Plus
� Configuration for plug-in modules
� vertical busbar L profile in the back
� internal degree og protection - IP 20 (finger proof)
� use of LBS modules possible (LBS adapter)
� internal separation from form 2 up to form 4b
� vertical busbar 3 & 4 pole
� Currents from 850 to 1900 A
Control Center Plug -in application
SEN PlusPlug -in modules:
� Modules for motor starters & feeders
� 25 mm module step – from 4E up to
36E
� High flexibility & compact design
� Fused or fuseless applications
� 3 & 4 pole version
SEN PlusWithdrawable modules
� Maximum safety for the operator
� Withdrawable incoming plug – special mechanism
� Connection of incoming plugs while the door is closed
� High availability
� Standard modules for feeders or motor starters
� 24 pole auxiliary plug – automatic contacting
� module sizes 5E .....36E
SEN PlusWithdrawable modules
� maximum safety for the operator
� withdrawable incoming plug – special worm gear drive
� connection of incoming plugs while the door is closed
� high availability
� standard modules for feeders & motor starters
� 24 poleauxiliary plug – automatic contacting
� module sizes 5E .....36E
SEN Plus
� Panel dedicated to load break switches type HSE Plus� High packing density – up to 40 feeder per column� Increased cable compartment ( 600 mm ) possible� Currents from 850 to 1900 A� Internal degree of protection - IP 20 (finger proof)�for fused feeders up to 630A� 60mm pole distance � 3 & 4 pole version� DIN & BS fuses� high short circuit breaking capacity� all accessories retrofitable on site
Control Center – fused feeders
SEN Plus
Intelligent MCC Solutions
SEN Plus
Communication protocol:
� Profibus DP class 1 to PCS
� Profibus DP class 2 for user
interface
Intelligent MCC solutions – EPOS DP
� Very compact design
� Optimized for use in GE equipment
� Fully flexible logic
� Mechanical adress switch
� WIN ESG user interface for control, diagnostics
& parameterization
� ATEX certified
SEN PlusIntelligent MCC solutions – Multilin MM200, 300
Communication protocols:
� Modbus RTU
� Profibus DP
� DeviceNet
� Ethernet Modbus TCP
� Flexible protection, control & communication options
� Small footprint
� Modular design
�Optional Control Panel or Color HMI
� Multiple Communication protocols
� Advanced monitoring & metering functionality
SEN PlusEntelliPro
� Profibus DP & Modbus RTU communication
� Optimized for use in SE System equipment
� Very compact (32 – 11kW starter per panel)
� Configurable Profibus-DP data block
� Pe-defined control logic
� Analog value logging
� Event logging with time stamping
� Communication redundancy
� Mechanical address switch
� Competitve price
� SIL / ATEX - certified
SEN Plus
Protection..• Overload (Class 5 to 40)• Earth fault (Residual current))• Phase loss• Thermistor (PTC)• Start current• Blocked rotor• Under load• Maximum starts per time• Self monitoring • External device monitoring
..diagnostic..• Time to overload trip, release• No. of operations• No. of motor starts • Motor ON-time, OFF-time• No. of overload trips• Maximum currents• Trip currents
..more..• Local control and display devices • Profibus DP and Modbus RTU• Predefined control logic• Free programmable logic• SIL, ATEX certified• ..
..options..• 4 – 20 mA output• 7 or 16 digital inputs
24 V DC or 110 – 240 V AC• 3 or 8 digital outputs• 24 V DC or 110 – 240 V AC supply
EntelliPro - Functions
SEN PlusEntelliPro
� 2 optional new HMI modules
� User level & password supported
� pre-programed screens
� Modbus RTU communication
� Fully programable
� Multilingual
SEN PlusEmpty Panels
Empty columns are dedicated for individual customized
solutions. The following functions ar eavailable:
� VPS mounting frames
� vertical mounting plate
� with or without horizontal busbar
� doors with „one handle closing system“
SEN PlusAdditional options - overview
� VPS – module for use of VP functions in MCCs type A
� corner panels for 600 & 800 mm cubicle depth
� base frames 100 mm
� arc proof cubicle to cubicle separation
� Mounting frames for installation of components to the compartment door
( stud bolts for door assembly )
� doors left & right hinged
� 200, 400 or 600 mm cable compartment for Control Centers
� cable supports in the cable compartment room
� standard roof cut-outs for cable glanding plates or ventilation plates ....
SEN Plus
SENplusProduct Certification
SEN PlusSEN Plus - Certifications
• IEC 61 439-2 / EN 60 439-1 Design verification by test
• IEC 61641 Internal Arcing
• IEEE 344 / UBC 97 Seismic tests
• 73/23/EWG Low Voltage regulation
• 89/336/EWG EMI regulation
• Gost Certificate Russian market
• CCC China
• Marine approval several
• all motorstarter combinations are tested according
coordination type II
� more than 1000 tested standard configurations
� all tests in independent, certified test labs
SEN PlusCertification• IEC 61439-2 Design verification by test
• IEC 61641 Internal Arcing
• IEEE 344 / UBC 97 Seismic tests
• 73/23/EWG EU Low Voltage directive
• 89/336/EWG EU EMI directive
• IEC 60947-4-1 Coordination type II
• Germanischer Lloyd Marine approval (ACB,
MCCB)
SEN Plus – individual certification on project basis
SEN Plus50°C ambient testing
Design verification process:
1. Test @ 35°C ambient
2. Calculated derating @ 50°C ambient
3. Verification of pre-calculated values
@ real 50°C ambient !
� Avoidance of hot-spots
� Behaviour of electrical components
� Varified derating factors for higher
ambient temperatures
� Fully KEMA certified !
SEN Plus
As an important product enhancement SEN Plus has now been tested under conditions of arcing due to internal fault according to IEC 61641
Tested values: up to 500V, 65kA, 200ms
IEC 61641 for personal protection under arcing conditions have been met.
Arc proof version
SEN PlusSeismic testing
Test 1 – according UBC 97:
Arig = 0.4g / 0.30g hor. / vert.A flex = 1.0g / 0.75g hor. / vert.
Test 2 – according IEEE 344:
(Seismic design for Nuclear Power Generation Stations)
RRS = 2.80g horizontal & vertical
Test result exceeds requirements for UBC 97 - seismic zone 4 !
SEN PlusMarine Approval
SEN PlusEnvironmental Testing
23 / GEIS 10-2011
� IEC 61439-1
Resistance to corrosion Severity test A
- Damp heat IEC 60068-2-30 6cycles of 24h each
40°C @ 95% humidity
- Salt mist IEC 60068-2-11 2 cycles of 24h each
Resistance to corrosion Severity test B in preparatio n
� Germanischer Lloyd
- Salt mist test 4 cycles, 2h each
- Damp heat 7 days, 40°C, humidity 93%
SEN Plus
Project data
•front view drawing•material costs •assembling time •manufacturing doc•copper drawings •assembling drawings •purchase order
Sales & Marketing
EngineeringMaterial Management
Production
ServiceEndcustomer
Assembly documentatio
n
�
�
User Manual
PowerDesign
Quotation- & Order Tool
�
�Technical documentation
Presentation / Brochure / CDNet planning tool ProceraPlus
Documentation concept
SEN PlusTechnical documentation
User manual
BrochureOverview of
technical data and functionality
More than 100 pages:
Definitions of functions
Mechanical and electrical
details
Typical configurations
Related standards
Saftey instructions
Handling instructions
Transport and erection
Data for cable connecton
Proposal for maintainance
Overview –Type test reports
• Overview on all type test reports
available for SEN Plus
• Test summary combined in 1 pdf
document
Documentation