General and Seismic Provisions

Embed Size (px)

Citation preview

  • 8/12/2019 General and Seismic Provisions

    1/143

    General And Seismic Provisions

  • 8/12/2019 General and Seismic Provisions

    2/143

    I. DESIGN DATA

    A. BRIDGE SITE TOPOGRAPHIC MAP

    Drawn to scale of 1:500 to 1:1000 depending on the width of the river

    The topo-map should be extended at least 200m upstream anddownstreamfrom the centerline of the proposed bridge

    Location plan showing the existing public and private structures/ utilitiesthatmaybe affected by the project.

    Cross-section at the approaches at 20m interval

    B. PROFILE ALONG THE CENTERLINE OF THE PROPOSED BRIDGE

    Showing the elevations of ordinary water level (OWL) andmaximum flood level MFL

  • 8/12/2019 General and Seismic Provisions

    3/143

    C. RIVER CROSS-SECTIONS

    @ 50m interval 100 to 200 meters upstream and downstream from theproposed bridge indicating the experienced high and ordinary waterelevations.

    D. HYDRAULIS / HYDROLOGIC ANALYSIS

    Topographic map showing the watershed area and the point ofinterest Calculation of required waterway opening

    Scour Analysis Calculation of Design Flood Level

  • 8/12/2019 General and Seismic Provisions

    4/143

    E. BORING DATA WITH SPT and GEOTECHNICAL REPORT

    Minimum of two deep borings shall be made at each abutment andpreferably

    an additional boring at each pier for multi-span bridges.

    Boreholes shall have minimum depth of 20 meters below the riverbed

    in ordinary soil or at least 3.0m in bedrock.

    Standard Penetration Test at maximum interval of 1.50 m and at everychange

    in soil stratum.

    Analysis for liquefaction potential.

  • 8/12/2019 General and Seismic Provisions

    5/143

    The subsurface exploration should define the following, where applicable :

    Soil Strata- Depth, thickness and variability- Identification and classification- Relevant engineering properties (i.e., shear strength, unit weight,compressibility, stiffness, permeability, expansion or collapse potential)

    Rock Strata- Depth of rock- Identification and classification- Quality (i.e., soundness, hardness, jointing, resistance to weathering if

    exposed, and solutioning )

    - Compressive strength (e.g.,uniaxial compression, point load index)- Expansion potential

    Ground water elevation

    Ground surface topography

  • 8/12/2019 General and Seismic Provisions

    6/143

    II. DESIGN CRITERIA & STANDARDS

    A. DESIGN SPECIFICATIONS

    AASHTO Standard Specifications for Highway Bridges, 16th Edition, 1996

    Department Order No. 75, Series of 1992,Re: DPWH Advisory for Seismic Design of Bridges.

    DPWH Design Guidelines, Criteria and Standards, Volumes 1 & 2(currently being updated)

    DPWH Standard Specifications, Vol. II, Highways, Bridges & Airports,1995 ed.

  • 8/12/2019 General and Seismic Provisions

    7/143

    B. LOADING SPECIFICATIONS

    (1) DEAD LOAD

    Selfweight plus allowance for future superimposed dead loads suchas wearing surface and weight of public utilities.

    (2) LIVE LOAD

    Six Classes of Highway Loadings :

    (Standard Designations)

    M 13.5 equivalent to H 15-44 M 18 equivalent to H 20-44 M 22.5 equivalent to H 25 MS 13.5 equivalent to HS 15-44 MS 18 equivalent to HS 20-44 MS 22.5 equivalent to HS 25

  • 8/12/2019 General and Seismic Provisions

    8/143

    M 13.5 27 kN (3 tons) 108 kN (12 tons) 15 tons GVW

    M 18 36 kN (4 tons) 144 kN (16 tons) 20 tons GVW

    M 22.5 45 kN (5 tons) 180 kN (20 tons) 25 tons GVW

    MS 13.5 27 kN 108 kN 108 kN 27 tons GVW

    MS 18 36 kN 144 kN 144 kN 36 tons GVW

    MS 22.5 45 kN 180 kN 180 kN 45 tons GVW

    ST

    D

    D

    T

    UC

    LO

    NG

    4.27 m

    4.27 m 4.27 to 9.14 m

  • 8/12/2019 General and Seismic Provisions

    9/143

    Clearance andLoad Lane Width

    3.04m (10)

    0.60 m

    (2)

    0.60 m

    (2)

    1.84 m

    (6)

    0.10 W

    0.10 W 0.40 W 0.40 W

    0.40 W0.40 W

    14 (4.27m) Variable

    6 ( 1

    . 8 4 m

    )

    W = the combined weight of the first two axles

    V = variable length 4.27 ~ 9.15 m. Spacing to beused is that which produces max. stresses.

  • 8/12/2019 General and Seismic Provisions

    10/143

    4.80 1.37 1.371.374.11 4.11 meters

    Permit Design Live Load *

    * P Loads (permit design live loads) are special vehicular loads that shall be appliedat the factored level in the Load Factor Design and at service level for fatigue considerationin steel structures.

    116 107107107107107 107 kN

    13 tons 12 tons 85 tons GVW

  • 8/12/2019 General and Seismic Provisions

    11/143

    Concentrated Load = 80 kN for Moment= 116 kN for Shear

    Uniform Load = 9.40 kN per meter of load lane

    Concentrated Load = 60 kN for Moment= 87 kN for Shear

    Uniform Load = 7.10 kN per meter of load lane

    L NELO

    NG

    M 13.5 and MS 13.5 Loading

    M 18 and MS 18 Loading

    Concentrated Load = 100 kN for Moment= 145 kN for Shear

    M 22.5 and MS 22.5 Loading

    Uniform Load = 11.75 kN per meter of load lane

  • 8/12/2019 General and Seismic Provisions

    12/143

    A heavy vehicle such as truck, trailer or vanoperated on any road or bridge violates the

    law if it:

    1. Exceeds the permissible single axle load of

    13,500 kg. or 13.5 metric tons.2. Exceeds the maximum allowed gross vehicleweight as stipulated in Republic Act 8794 (Anti-Overloading Law) and its regulations publishedin 2001.

  • 8/12/2019 General and Seismic Provisions

    13/143

    MAXIMUM ALLOWABLE GROSS VEHICLE WEIGHT (GVW) PER R.A. 8794

    TRUCKS / TRAILER DESCRIPTION MAX. ALLOWABLEGROSS WEIGHT

    TRUCK WITH 2

    AXLE (6 WHEELS)16,880

    TRUCK WITHTANDEM REAR

    AXLE 3 AXLES (10WHEELS)

    27,250

    TRUCK WITHTANDEM REAR

    AXLE 4 AXLES (14WHEELS)

    29,700

    CODE 1-1

    Based on the maximum allowable axle load of 13,500Kgs.

    CODE 1-2

    CODE 1-3

  • 8/12/2019 General and Seismic Provisions

    14/143

    MAXIMUM ALLOWABLE GROSS VEHICLE WEIGHT (GVW) PER R.A. 8794

    TRUCKS / TRAILER DESCRIPTION MAX. ALLOWABLEGROSS WEIGHT

    TRUCK SEMI-TRAILER WITH 3

    AXLE (10 WHEELS)

    30,380

    TRUCK SEMI-TRAILER 4 AXLE

    (14 WHEELS)30,380

    TRUCK SEMI-TRAILER 4 AXLE

    (14 WHEELS) 30,380

    Based on the maximum allowable axle load of 13,500Kgs.

    CODE 11-1

    CODE 11-2

    CODE 12-1

  • 8/12/2019 General and Seismic Provisions

    15/143

    MAXIMUM ALLOWABLE GROSS VEHICLE WEIGHT (GVW) PER R.A. 8794 Based on the maximum allowable axle load of 13,500Kgs.

    CODE 11-11

    CODE 12-2

    CODE 11-3

    TRUCKS / TRAILER DESCRIPTIONMAX. ALLOWABLE

    GROSS WEIGHT

    TRUCK SEMI-TRAILERWITH 5 AXLE (18

    WHEELS)37,800

    TRUCK TRAILER WITH 2AXLE AT MOTOR

    VEHICLE AND 3 AXLE ATTRAILER (18 WHEELS)

    30,378

    TRUCK TRAILER WITH 2AXLE AT MOTOR

    VEHICLE AND 2 AXLE ATTRAILER (14 WHEELS)

    30,380

  • 8/12/2019 General and Seismic Provisions

    16/143

    MAXIMUM ALLOWABLE GROSS VEHICLE WEIGHT (GVW) PER R.A. 8794

    TRUCKS / TRAILER DESCRIPTIONMAX. ALLOWABLE

    GROSS WEIGHT

    TRUCK TRAILERWITH 2 AXLE AT

    MOTOR VEHICLEAND 3 AXLE AT

    TRAILER (18

    WHEELS)

    36,900

    TRUCK TRAILERWITH 3 AXLE AT

    MOTOR VEHICLEAND 3 AXLE AT

    TRAILER (22WHEELS)

    41,000

    TRUCK TRAILERWITH 3 AXLE AT

    MOTOR VEHICLEAND 2 AXLE AT

    TRAILER (18WHEELS

    37,800

    Based on the maximum allowable axle load of 13,500Kgs.

    CODE 11-12

    CODE 12-3

    CODE 12-11

  • 8/12/2019 General and Seismic Provisions

    17/143

    MAXIMUM ALLOWABLE GROSS VEHICLE WEIGHT (GVW) PER R.A. 8794

    TRUCKS / TRAILER DESCRIPTIONMAX. ALLOWABLE

    GROSS WEIGHT

    TRUCK TRAILERWITH 3 AXLE AT

    MOTOR VEHICLEAND 3 AXLE AT

    TRAILER (22WHEELS)

    36,900

    Based on the maximum allowable axle load of 13,500Kgs.

    CODE 12-12

  • 8/12/2019 General and Seismic Provisions

    18/143

    (3) IMPACT

    Impact , I = 15.24 / ( L + 38)

    where : I = impact fraction (maximum of 30%)L = span length in meters

    (4) SIDEWALK LOADING

    For spans up to 7.92 m .4070 Pa

    For spans 7.92 to 30.5 m...2870 Pa

    For spans > 30.5 m ..p =[ 1435 + 43800 / L ] [ (1.67 - W) / 15.2] Pa

    L = span length, m W = sidewalk width, m

  • 8/12/2019 General and Seismic Provisions

    19/143

    (5) WIND LOAD

    Superstructure Design

    For trusses and arches : 3.59 kPa

    For girders and beams : 2.39 kPa

    Based on 160 km per hour wind velocity.

    Substructure Design

    Force transmitted to the substructure by the superstructure plus the forces applieddirectly

    to the substructure by wind load :

    WLSUBSTRUCTURE

    = 1.92 kPa ( 40 psf )

    (6) THERMAL FORCE

    Provisions shall be made for stresses or movements resulting from variation in temp.Under local condition the range of temperature rise and fall could be taken as : + 12.5 oC

  • 8/12/2019 General and Seismic Provisions

    20/143

    20

    Elevation of Passage

    Deck Type

    Through Type

  • 8/12/2019 General and Seismic Provisions

    21/143

    21

    Alignment

    Curved Type

    Straight Type

  • 8/12/2019 General and Seismic Provisions

    22/143

    22

    Structural Type

    Girder Type

    Rigid Frame Type

    Arch Type

  • 8/12/2019 General and Seismic Provisions

    23/143

    23

    Structural Type

    Cable Stay

    Suspension Type

  • 8/12/2019 General and Seismic Provisions

    24/143

    24

    2. BRIDGE ENGINEERINGTERMINOLOGY

  • 8/12/2019 General and Seismic Provisions

    25/143

    25

    Bridge Composition

    Superstructure

  • 8/12/2019 General and Seismic Provisions

    26/143

  • 8/12/2019 General and Seismic Provisions

    27/143

    27

    Superstructure

  • 8/12/2019 General and Seismic Provisions

    28/143

    28

    Superstructure

  • 8/12/2019 General and Seismic Provisions

    29/143

    29

    Substructure

  • 8/12/2019 General and Seismic Provisions

    30/143

    30

    Substructure

  • 8/12/2019 General and Seismic Provisions

    31/143

  • 8/12/2019 General and Seismic Provisions

    32/143

    DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS

    BRIDGE PLANNING &

    DESIGN

    GENERAL PROVISIONS

  • 8/12/2019 General and Seismic Provisions

    33/143

  • 8/12/2019 General and Seismic Provisions

    34/143

  • 8/12/2019 General and Seismic Provisions

    35/143

    1. Navigable river At least 3.75 meters from the designflood level (DFL)

    2. Hydraulic At least 1.50 meters for streams

    carrying debris At least 1.00 meters for others

    3. Highway/Underpass/Tunnel At least 4.88 meters

    VerticalClearances

  • 8/12/2019 General and Seismic Provisions

    36/143

    A. Bridge Alignment

    1. Normal bridge A transverse structureperpendicular to the bank of the riveror creek.

    2. Skew bridge A transverse structurehaving an angle of less than 90 0 fromthe bank of the river creek.

    3. Curved bridge When the structure orportion of the structure is within andfollowing the horizontal curvealignment of the road.

    GEOMETRICS

  • 8/12/2019 General and Seismic Provisions

    37/143

    No. of Lanes Min. RoadwayWidth

    Min. No. of Girders

    1 Lane

    2 Lanes2 LanesMore than 2lanes

    4.00 meters

    6.70 meters7.30 metersvariable

    3 girders

    4 girder (rural)4 girders(urban)Not less than 6

    girders

    B. Span of Bridges

    Odd number of spans shall be preferably usedto avoid a pier at the center of river or creek.

    NUMBER OF GIRDERS IN RELATION TO NUMBER OF

    LANES

  • 8/12/2019 General and Seismic Provisions

    38/143

    C. Determination of Length of Bridge

    1. Sketch the proposed slopes of thegrouted riprap following the slope of thebanks as close as possible (1:1 for cut, 1-1/2:1 for fill).

    2. Determine the top of roadway elevationbased on the maximum flood waterlevel, freeboard and depth of girders.

    3. The intersections of the slopes of groutedriprap and the top of the roadwayelevation represent the length of bridge

    required.

  • 8/12/2019 General and Seismic Provisions

    39/143

  • 8/12/2019 General and Seismic Provisions

    40/143

    D. Types/Classification of Superstructure

    According to Materials Used

    1. Timber Bridge

    2. Concrete Bridge

    a. Reinforced Concreteb. Prestressed Concrete

    3. Steel Bridge

    a. Steel Plate Girderb. Steel I-Beamc. Steel Trussd. Steel Box Girder

  • 8/12/2019 General and Seismic Provisions

    41/143

    According to Usage

    1. Temporary a bridge designed for a short

    life span2. Permanent a bridge with a designed life

    span of at least fifty (50) years before it iscompletely replaced

    According to System of Design

    1. Simple Spans

    2. Continuous Spans3. Cantilever Span4. Suspension Bridge5. Cabled Stayed

  • 8/12/2019 General and Seismic Provisions

    42/143

    E. Recommended Limits of Span of DifferentSuperstructure in the Philippines

    1. Timber Trestle Bridge For span not morethan 6.00 meters

    2. Concrete Bridge

    a) Reinforced Concrete Precast Slab orReinforced Flat Slab Span from 6.00mto 12.00m.b) Reinforced Concrete Deck Girder(RCDG) span from 8.00m to 24.00m.c) Reinforced Concrete Box Girder span

    from 22.00m to 30.00m.

  • 8/12/2019 General and Seismic Provisions

    43/143

    d) Reinforced Concrete Hollow Slab Bridge

    span from 10.0m to 20.0m.

    e) Prestressed Concrete Bridge

    - Channel Beams

    span from 11.00mto 14.0m.- Tee Beams span from 15.00m to

    18.00m.- I-Beams span from 15.00m to45.00m.- Box Girders span over 30.00m.

  • 8/12/2019 General and Seismic Provisions

    44/143

    3. Steel Bridges

    a) Steel I-Beam span from 15.00 to 30.00m.

    b) Steel Plate Girder span from 20.00m to50.00m.c) Steel Box Girder span from 30.0m to 100m.d) Bailey Bridge span from 9.00m. to 30.00m.

    e) Steel Truss span from 40.00m to130.00m.4. Suspension Bridge span from 70.00m and over.

    5. Cable Stayed Bridge For span from 70.00m and

    over.

  • 8/12/2019 General and Seismic Provisions

    45/143

    SUBSTRUCTURE

    A. Factors in Selecting the Type ofSubstructure

    1. Abutment

    a) Height of fill at the approaches.b) Kinds of superstructure to be used.

    c) Scouring character of river bank.d) Soil encountered at the abutment

    foundation.

  • 8/12/2019 General and Seismic Provisions

    46/143

    2. Pier

    a) Velocity of current and nature of drift.b) Kinds of superstructure to be used.

    c) Soil encountered at the pierfoundation.d) Direction of flow of the river with

    respect to the longitudinal axis of the

    bridge.e) Profile along the centerline of thebridge.

  • 8/12/2019 General and Seismic Provisions

    47/143

    B. SubstructureElements

    1. Abutment

    Two Basic Categories:

    a. Open End Abutments- Diaphragm or integral

    type- Seat type- Spill through type

  • 8/12/2019 General and Seismic Provisions

    48/143

    b. Closed Type Abutments

    - Cantilever type

    - Restrained type.

    - Rigid frame type

    - Cellular or vaulted type

    - Gravity or semi-gravity type

    - Reinforced earth type

    Types of Abutment Commonly Used:- Abutments on pile bent- Abutments on two columns- Cantilever type

  • 8/12/2019 General and Seismic Provisions

    49/143

    2. Piers

    Types of Piers Commonly Used- Piers with solid shaft- Piers with two columns- Piers with single column

    - Piers on pile bentC. Foundation

    Factors in Selecting the Type of

    Foundationa. The height of the substructure

    b. Characteristics of the foundation soil

    at bridge site.

  • 8/12/2019 General and Seismic Provisions

    50/143

  • 8/12/2019 General and Seismic Provisions

    51/143

    Requirements for the Use of the DifferentTypes of Piles

    Piling shall be considered when footingscannot be founded on rock or other solid

    foundation material. Penetration for any pile shall be not lessthan 3.00m in hard cohesive or densegranular material nor less than 6.00m in

    soft cohesive or loose granular material.

  • 8/12/2019 General and Seismic Provisions

    52/143

    Type of Piles

    1. Timber Pile

    used for temporary construction,revetments, fender and similar work.2. Reinforced Concrete Piles used as foundation

    piles (Precast or Cast-in-Place) for bridges.3. Steel Piles used where hard driving is

    expected.4. Composite Steel/Concrete Piles used if the

    portion of the pile is exposed to corrosiveenvironment and hard driving is expected

    5. Prestressed Concrete Piles

    used as foundationpiles for bridges where larger bearing capacityand longer piles are required.

    PORTAL STRUT

  • 8/12/2019 General and Seismic Provisions

    53/143

    STEEL TRUSS BRIDGE

    TOP CHORD

    BOTTOM CHORD

    END POST

    DIAGONAL MEMBER

    VERTICAL MEMBER

    PORTAL STRUT

    PORTAL BRACING

  • 8/12/2019 General and Seismic Provisions

    54/143

    STEEL TRUSS BRIDGE

  • 8/12/2019 General and Seismic Provisions

    55/143

    STEEL EXPANSION

    JOINT

  • 8/12/2019 General and Seismic Provisions

    56/143

  • 8/12/2019 General and Seismic Provisions

    57/143

  • 8/12/2019 General and Seismic Provisions

    58/143

    NORMAL BRIDGE ALIGNMENT

  • 8/12/2019 General and Seismic Provisions

    59/143

    REINFORCED CONCRETE GIRDER

    MAIN GIRDER

    INTERIOR DIAPHRAGM

  • 8/12/2019 General and Seismic Provisions

    60/143

  • 8/12/2019 General and Seismic Provisions

    61/143

  • 8/12/2019 General and Seismic Provisions

    62/143

  • 8/12/2019 General and Seismic Provisions

    63/143

    PRESTRESSED CONCRETE GIRDER BRIDGEPROVIDED W/SHEAR BLOCKS

  • 8/12/2019 General and Seismic Provisions

    64/143

    EXPANSION DAM

  • 8/12/2019 General and Seismic Provisions

    65/143

  • 8/12/2019 General and Seismic Provisions

    66/143

    CABLE RESTRAINER

  • 8/12/2019 General and Seismic Provisions

    67/143

    SOLID SHAFT

    FOOTING

    COPING

    PIER ELEMENTS

  • 8/12/2019 General and Seismic Provisions

    68/143

    PEDESTAL

    SHEAR

    BLOCK

  • 8/12/2019 General and Seismic Provisions

    69/143

  • 8/12/2019 General and Seismic Provisions

    70/143

  • 8/12/2019 General and Seismic Provisions

    71/143

  • 8/12/2019 General and Seismic Provisions

    72/143

  • 8/12/2019 General and Seismic Provisions

    73/143

    ARCH BRIDGE

  • 8/12/2019 General and Seismic Provisions

    74/143

  • 8/12/2019 General and Seismic Provisions

    75/143

  • 8/12/2019 General and Seismic Provisions

    76/143

  • 8/12/2019 General and Seismic Provisions

    77/143

  • 8/12/2019 General and Seismic Provisions

    78/143

  • 8/12/2019 General and Seismic Provisions

    79/143

  • 8/12/2019 General and Seismic Provisions

    80/143

  • 8/12/2019 General and Seismic Provisions

    81/143

  • 8/12/2019 General and Seismic Provisions

    82/143

  • 8/12/2019 General and Seismic Provisions

    83/143

  • 8/12/2019 General and Seismic Provisions

    84/143

  • 8/12/2019 General and Seismic Provisions

    85/143

    DIAPHRAGM WALL

  • 8/12/2019 General and Seismic Provisions

    86/143

  • 8/12/2019 General and Seismic Provisions

    87/143

    BOD SEMINAR PRESENTATION

  • 8/12/2019 General and Seismic Provisions

    88/143

    SEISMIC DESIGN OF BRIDGES

    COURSE OUTLINE :

    1. HISTORICAL BACKGROUND

    2. DESIGN PHILOSOPHY

    3. GOVERNING REGULATION

    4. AASHTO 1996 SEISMIC DESIGN PROVISIONS

    5. ANALYSIS PROCEDURE

    6. BRIDGE RETROFITTING

  • 8/12/2019 General and Seismic Provisions

    89/143

    SEISMIC DESIGN

  • 8/12/2019 General and Seismic Provisions

    90/143

    YEAR CRITERIA /SPECIFICATION

    PROVISIONS

    1987NSCP VOL.II, 1ST EDITION (BASED ONAASHTO 13TH EDITION, 1983)

    (a) Equivalent Static Force MethodEQ = CFWC = Response Coefficient (not less than 0.10) for

    various depths of alluvium to rocklike material)F = Framing factor, (1.0 for single column, 0.80 for

    structures with continuous frames)(b) EQ = 0.10(DL +0.50LL)(c) For complex structures, Response Dynamic

    Approach is recommended.

    1992

    DPWH Department

    Order No. 75 Seriesof 1992.DPWHAdvisory for SeismicDesign of Bridges

    Amended all existing guidelines on seismic design.

    Prescribed the 1991 AASHTO 1991 or latest editionas the reference specification Recommended new design concepts for seismicresistant design of bridges.

    SEISMIC DESIGN PHILOSOPHY

  • 8/12/2019 General and Seismic Provisions

    91/143

    It is not economically practical to proportion bridge members so that they will remainundamaged after a severe earthquake, but a failure that leads to collapse of the

    structure must not be allowed to occur. For this reason it is essential to design bridgestructures with sufficient ductility to dissipate the energy of earthquake motions withoutreducing the strength of the bridge to the point of collapse.

    The basic philosophy in seismic design of bridges is to design a bridge to resist smallto moderate earthquakes in the elastic range without significant damage. In the event ofa large earthquake, bridges and their components may suffer damage but should notcause collapse of all or any part of the bridge. Where possible, the damages that doesoccur should be readily detectable and accessible for inspection and repair.

    The bridge should be designed so as to be usable by emergency traffic after simple and

    very rapid repairs and should be capable of permanent repair to an acceptable level forboth vehicular and seismic loading.

    Essential bridges are required to function during and immediately after an earthquakeand must meet additional requirements. These are bridges designated as essential onthe basis of criteria such as social/survival and security / defense.

    Definition for importance of a bridge structure is subjective influenced by factors

  • 8/12/2019 General and Seismic Provisions

    92/143

    such as: ADT, available detour, use for emergency vehicles, replacement cost, andthe nature and importance of the route being crossed by the bridge.

    DESIGN APPROACH

    The analytic approach in seismic design of bridges includes the determination ofthe member forces from an elastic design response spectrum coefficient.The design forces for each bridge component are then obtained by dividing the

    elastic forces by a Response Modification Factor (R). Well confined, ductilecolumns are designed for lower-than-expected forces obtained from the analysis.Columns joints are designed and detailed to deform in a plastic manner when theseismic forces exceeds the lower design forces. This approach is completelydifferent than the procedures used in the earlier AASHTO Standard Specifications.

    Design displacements are considered as important because of many loss-of-spantype failures in the past earthquakes attributed in part to relative displacementeffects. Thus minimum support lengths at abutments, piers and hinge seats arespecified to prevent this type of failure.

    Anchors and connections are important elements in maintaining the overall integrityf b id Th f bl i d i f ifi d

  • 8/12/2019 General and Seismic Provisions

    93/143

    of a bridge structure. Therefore reasonably conservative design forces are specifieduse in their design. An additional requirement to prevent significant relativedisplacement is to provide horizontal linkages between adjacent sections of the

    superstructures using cables or an equivalent mechanism. Deck continuity can alsobe utilized to provide for continuity.

    Current design and analysis of bridges to resist earthquakes now include:

    + Force level defined as seismic design spectra+ Abutment stiffness effects are considered

    + The effects of ductility are considered

    + Modal dynamic elastic analysis is used as a routine design tool

    + Introduction of continuity to mobilize the maximum number of bridge components

    + Consideration of soil-structure interaction effects.

    GOVERNING REGULATION

  • 8/12/2019 General and Seismic Provisions

    94/143

    DEPARTMENT ORDER NO. 75, Series of 1992SUBJECT : DPWH Advisory for Seismic Design of BridgesJuly 17, 1992

    The threat of earthquakes occurring in the Philippines can no longer bediscounted. Past and recent events have shown devastating effects ofearthquakes not only on buildings but also on highways and bridges. In

    addition to the loss of lives, the recent Cabanatuan and Baguioearthquakes caused the closure of many highways and the collapse ofmany bridges which are designed based on older AASHTO StandardSpecifications resulting in millions of pesos in repair and/or replacements.

    Considering that highways and bridges are the main arteries in bringingrelief to victims of earthquakes and other calamities, they should beserviceable at all times especially during emergencies.

    GOVERNING REGULATION

    DEPT ORDER NO 75 cont

  • 8/12/2019 General and Seismic Provisions

    95/143

    In modern seismic design of bridges, the basic design philosophy is for thebridge to resist small to moderate earthquakes in the elastic range withoutsignificant damage. In case of large earthquakes, a bridge may suffer damagebut this should not cause collapse of all or any of its parts and such damageshould readily be detectable and accessible for inspection and repair.

    Therefore, to mitigate, if not prevent damage/s to bridges due to earthquakes,and for the guidance of engineering professionals and DPWH engineersparticularly those undertaking the design of bridges, the DPWH is issuing thisADVISORY :

    1. As a minimum requirement, the design of bridges shall conform with

    the current AASHTO Standard Specifications for Highway Bridges, 14thEdition, and the Guide Specifications for Seismic Design (1989 or latestedition) or the 1991 AASHTO Standard Specifications adopting the GuideSpecifications for Seismic Design (AASHTO Interim Specifications - Bridges)

    DEPT ORDER NO.75 cont..

  • 8/12/2019 General and Seismic Provisions

    96/143

    DEPT ORDER NO.75 cont..

    2. Design Concept to be adopted shall be as follows :

    a) Continuous bridges with monolithic multi-column bents have highdegree of redundancy and are the preferred type of bridge structureto resist seismic shaking. Deck discontinuities such as expansion joints

    and hinges should be kept to an absolute minimum . Suspended spans,brackets, rollers, etc are not recommended.

    b) Where multi-span simple span bridges are justified, decks should becontinuous.

    c) Restrainers (horizontal linkage between adjacent span) are required at

    all joints in accordance with the AASHTO Guide Specifications forSeismic Design and generous seat widths at piers and abutmentsshould be provided to prevent loss-of-span failures.

    DEPT ORDER NO. 75 cont... d) Transverse reinforcements in the zones of yielding is essential to the

    successful performance of reinforced concrete columns during

  • 8/12/2019 General and Seismic Provisions

    97/143

    successful performance of reinforced concrete columns duringearthquqkes. Transverse reinforcement serves to confine the mainlongitudinal reinforcement and the concrete within the core of the

    column, thus preventing buckling of the main reinforcements.e) Plastic hinging should be forced to occur in ductile column regions of

    the pier rather than in the foundation unit. A scheme to protect theabutment piles from failure is often accomplished by designing thebackwall to shear-off when subjected to the design seismic lateral

    force that would otherwise fail the abutment piles.f) The stiffness of the bridge as a whole should be considered in the analysis.

    In irregular structures, it is particularly important to include the soil-structure interaction.

    This Advisory amends the existing DPWH Guidelines on the SeismicDesign of Bridges and shall take effect immediately.

    (Sgd) JOSE P. DE JESUSSecretary

    FIG. 2A ILLUSTRATING THE PROVISIONSOF DPWH D.O. No. 75

  • 8/12/2019 General and Seismic Provisions

    98/143

    MONOLITHICABUTMENT

    CONTINUITYMINIMUMJOINTS

    GENEROUSSEAT WIDTH

    RESTRAINERS

    PLASTICHINGES

    MULTI-COLUMN BENT IS PREFERRED OVER SINGLE COLUMN PIERS THE STIFFNESS OF THE WHOLE BRIDGE SHOULD BE COSIDERED IN THE ANALYSIS TRANVERSE REINFORCEMENT AT REGIONS OF YIELDING (PLASTIC HINGES)

  • 8/12/2019 General and Seismic Provisions

    99/143

    Deck continuity

  • 8/12/2019 General and Seismic Provisions

    100/143

  • 8/12/2019 General and Seismic Provisions

    101/143

  • 8/12/2019 General and Seismic Provisions

    102/143

    Assessment of Seismic Deficiencies

  • 8/12/2019 General and Seismic Provisions

    103/143

    & Retrofitting TechniquesI. Continuity & Restrainers

    Deficiencies with respect to continuity often result in totalloss of support and falling of a span

    Bridges having deficiencies include:

    Simply-supported spans on sliding bearings withinadequate seat width

    Continuous spans with sliding supports within the span

    Pinned or fixed bearings with very low lateral orlongitudinal load capacity

    Sliding supports that have to be guided in the slidingdirection. Guides may be unable to resist transverseload or structure can jump out of guides that are toosmall

    Solution

  • 8/12/2019 General and Seismic Provisions

    104/143

    Restrainers

    Solution

    Seat type piers (R.C. Superstructures)

    The main purpose of restrainers is to prevent spans fromfalling off their supports during the maximum credible EQ.

    Restrainer Cable

    TYPICAL RESTRAINER DETAILS

  • 8/12/2019 General and Seismic Provisions

    105/143

    Restrainer at Pier With

    Positive Tie to Pier

    Restrainer Cable

    Restrainer at Pier Without

    Positive Tie to Pier

  • 8/12/2019 General and Seismic Provisions

    106/143

    RestrainerCable

    Vertical Motion Restrainer

  • 8/12/2019 General and Seismic Provisions

    107/143

    C bl R i

    Solution

  • 8/12/2019 General and Seismic Provisions

    108/143

    Cable Restrainers

  • 8/12/2019 General and Seismic Provisions

    109/143

    TYPICAL SHEAR BLOCK (restrainer) DETAILS

  • 8/12/2019 General and Seismic Provisions

    110/143

    A

    A SHEARBLOCKS

    END DIAPHRAGMS

    SHEAR

    BLOCK

    Additional SlabReinforcement

    Induced Cra ck

    ENDDIAPHRAGMS

    SHEAR

    BLOCKS

    2. @ Expansion Ends1. Continuous Deck Slab

    SECTION AA SECTION AA

    Solution:

  • 8/12/2019 General and Seismic Provisions

    111/143

    PROVISION OF CONCRETE SHEAR BLOCKS(restrains both longitudinal and transversemovement of the superstructure)

    Steel Longitudinal Shear Keys

  • 8/12/2019 General and Seismic Provisions

    112/143

    Transverse shear keys

  • 8/12/2019 General and Seismic Provisions

    113/143

  • 8/12/2019 General and Seismic Provisions

    114/143

    II. Bearings

    Usually a loss-of-support failure results in thecollapse of the span and is considered to beunacceptable while less drastic failures may beconsidered as possibly acceptable

    The most common modern bearing is theelastomeric bearing pad consisting of steel platesin layers alternating with rubber or anotherelastomer

    Assessment of Seismic Deficiencies &Retrofitting Techniques

    Luzon 1990Damage

  • 8/12/2019 General and Seismic Provisions

    115/143

    Toppling of bearings

    Solution

  • 8/12/2019 General and Seismic Provisions

    116/143

    Bearing embedment in concrete

    This will prevent shear failure and toppling of the bearings.

    In addition, if spans become displaced from the bearings, theconcrete cap will prevent collapse.

    New concrete cap

  • 8/12/2019 General and Seismic Provisions

    117/143

    Kobe 1995Damage

  • 8/12/2019 General and Seismic Provisions

    118/143

    Loss of support failure

    Solution

  • 8/12/2019 General and Seismic Provisions

    119/143

    Supplementalsupport

    Seat widening

    Assessment of Seismic Deficiencies &

  • 8/12/2019 General and Seismic Provisions

    120/143

    III. Columns and Piers

    Key considerations for column & piers:

    For bridges designed to most codes,columns will almost always be expected toyield during strong seismic shaking.Sudden loss of flexural or shear strengththat result in structural collapse must beavoided. In the case of existing bridges,such conditions must be corrected.

    All possible modes of column failure mustbe assessed in terms of their effects on theglobal stability of the structure.

    Retrofitting Techniques

    Assessment of Seismic Deficiencies &Retrofitting Techniques

  • 8/12/2019 General and Seismic Provisions

    121/143

    Common column & pier deficiencies:

    Inadequate development of vertical steel due to inadequatelap splice between vertical bars and dowels.

    Splicing of column bars and dowels at column sectionswhere the development of plastic moments are required,thus limiting the length of hinging.

    Insufficient amount of transverse reinforcement resulting inpoor confinement of the concrete core and insufficient shearstrength to permit the development of flexural hinging inthe column.

    Poor detailing of confinement reinforcement, including largespacing of transverse & longitudinal bars, inadequate endanchorage of transverse reinforcement, and lack ofsufficient supplementary core ties in larger rectangularcolumn sections.

    Insufficient flexural strength and ductility.

    Retrofitting Techniques

  • 8/12/2019 General and Seismic Provisions

    122/143

    Damage

  • 8/12/2019 General and Seismic Provisions

    123/143

    DamageColumn failure - lack of ductility

    San FernandoEarthquake 1971

  • 8/12/2019 General and Seismic Provisions

    124/143

    Solution

  • 8/12/2019 General and Seismic Provisions

    125/143

    Steel Jackets for Columns & Piers

    An effective solution to column failure problems is pre-fabricatedsteel jackets to provide passive confinement

    Characteristics of column jacketing are: Prefabricated steel jacket is usually circular or elliptical in shape

    and annular space is grouted. A short gap at the end(s) isprovided to avoid crushing failure.Decreases tendency for buckling of the column longitudinal bars.Improves column ductility.Increases shear resistance of columnFull height or partial height jackets may be utilized asappropriate.

    Caution : Improperly detailed jacketing scheme may force flexural orshear failure into foundations or cap beam creatingunfavourable failure mode.

    Solution

  • 8/12/2019 General and Seismic Provisions

    126/143

    Steel Jackets

    Solution

    Solution

  • 8/12/2019 General and Seismic Provisions

    127/143

    Concrete Jackets

    Column Steel Jacket

  • 8/12/2019 General and Seismic Provisions

    128/143

  • 8/12/2019 General and Seismic Provisions

    129/143

    Extended column spiralsinto coping, min. = D/2

  • 8/12/2019 General and Seismic Provisions

    130/143

    . . . . . . . . . . . . .

    . . . . . . . . . . . .

    Column Section

    D

    d

    H

    Extended columnspirals intofooting, min.=D/2

    Column End RegionH/6, D, or 1 8

    Column End RegionH/6, D, or 18

    dd

    TYPICAL PIER DETAILS

    16mm f @300 o.c .

    Extended Pile Reinf.w/ hoops or ties

    Assessment of Seismic Deficiencies &Retrofitting Techniques

  • 8/12/2019 General and Seismic Provisions

    131/143

    VI. Foundations

    Seismic retrofitting of foundations is one of the most difficultand costly aspects of retrofitting works and often involves adisruption of service

    Deficiencies in foundations include:

    Undersize footings or inadequate number of pilesInsufficient flexural and shear strength of footings or pilecapsLack of top steel in footings or pile capsInadequate anchorage of piles into capsInsufficient horizontal shear capacity of column-footingdue to insufficient vertical reinforcement at interfaceInadequate anchorage of vertical column bars in footingsExcessive movements due to liquefaction.

    Modes of failure for spread footingsDamage

  • 8/12/2019 General and Seismic Provisions

    132/143

    Modes of failure for pile footingsDamage

  • 8/12/2019 General and Seismic Provisions

    133/143

    Footing Retrofit

    Solution

  • 8/12/2019 General and Seismic Provisions

    134/143

    g

  • 8/12/2019 General and Seismic Provisions

    135/143

    III DESIGN PROCEDURE

  • 8/12/2019 General and Seismic Provisions

    136/143

    III. DESIGN PROCEDURE

    1. Preliminary layout of the proposed bridge.(General Plan and Elevation)

    - Review hydraulic/hydrologic analyses to determine the

    required waterway opening and bridge elevation.

    - Survey data (topographic map of bridge site, profiles, rivercross sections, water elevations)

    - Bridge geometric requirements such as vertical/ horizontalalignments, roadway width, sidewalk/ shoulder width, medianwidth and vertical clearance.

    - Preliminary selection of the types of superstructures,substructures and foundations.

    TOTAL BRIDGE LENGTHBased on Required Waterway Width, Minimum Vertical Clearance, etc

  • 8/12/2019 General and Seismic Provisions

    137/143

    OWL

    MFL

    MINIMUM CLEARANCE :1.0 m (no debris)1.5 mor as required for navigation TOP OF ROADWAY

    ELEVATION

    BOTTOM OFGIRDER EL..

    SLOPE

    SLOPE

    (PROFILE ALONG THE CENTERLINE OF BRIDGE)

    Fig. 4 PRELIMINARY LAYOUT OF A PROPOSEDBRIDGE

    2. Establish the design criteria andspecifications

  • 8/12/2019 General and Seismic Provisions

    138/143

    (General Notes)

    - Design Specifications / Standards

    - Design Live Load

    - Design Stresses

    - Seismic design criteria :

    Ground acceleration coefficient., AImportance classification, ICSeismic Performance Category, SPC

    - Materials specifications

    - Construction specifications

    Agas-Agas Bridge ProjectContract PackageV

  • 8/12/2019 General and Seismic Provisions

    139/143

    Contract Package VPhilippine-Japan Friendship Highway Rehabilitation Project(Visayas Section, Phase II)

    3. Final selection of the type of structures.

    Superstructures & substructures :

  • 8/12/2019 General and Seismic Provisions

    140/143

    Superstructures & substructures :

    - Span Lengths

    - Height of Substructures

    - Size Limitations

    Foundations :

    - depth of scour

    - depth of hard strata

    - liquefaction potential of foundation materials

    - magnitude of loads from superstructure

  • 8/12/2019 General and Seismic Provisions

    141/143

    5. Design of Substructures

  • 8/12/2019 General and Seismic Provisions

    142/143

    - Check for depth of scour.

    - Check for liquefaction potential.

    - Create a stick model of the bridge for structural analyses (see Fig.5)

    - Analyze for various combination of loads(see AASHTO Table 3.22.1A for load combinations)(see Fig. 6 & 7, Seismic Design Flow Charts)

    - Design pier coping and columns.

    - Design pier footings and foundations.

    - Detailing

  • 8/12/2019 General and Seismic Provisions

    143/143