4
Generator drive Stage III A engine range Generator Drive Applications Diesel Engines 13505_PowerGen_StageIIIA_4pg_Brc_by_4c_8-5x11v.indd 1 12/11/12 8:00 AM

Generator Drive Applications - GM TURBO · Generator drive applications 2 Fuel efficiency ... Email: [email protected] JohnDeere.com.au JohnDeere.co.nz Far East John Deere Asia

  • Upload
    vodiep

  • View
    222

  • Download
    0

Embed Size (px)

Citation preview

Generator drive Stage III A engine range

Generator Drive ApplicationsDiesel Engines

13505_PowerGen_StageIIIA_4pg_Brc_by_4c_8-5x11v.indd 1 12/11/12 8:00 AM

Generator drive applications

2

Fuel efficiencyGet more power with less fuel ― while meeting emissions regulations ― thanks to our charge-air-cooling, low-friction pistons and advanced electronic controls.

Quiet operationJohn Deere generator drive engines have low noise and vibration. This helps manufacturers build quiet gen-sets with less isolation of the canopy.

Proven reliabilityKnown throughout the world for their reliability and durability, John Deere engines feature sturdy, compact engine blocks and are enhanced with innovative technological advancements. Dynamically balanced moving parts such as the crankshaft make our engines quieter and limit vibrations, and components such as the thermostat housing and the air intake manifold have been integrated into the cylinder head to reduce leaks.

Compact powerWith John Deere engines, you get maximum power in a smaller package and installation space. It’s like having a 6-cylinder engine in a 4-cylinder size. Our current 4.5L and 6.8L engines perform well in applications where larger displacement engines are traditionally required, meaning smaller canopies and lower axle weight.

Installation flexibilityWe offer many options to ensure perfect integration and provide single-side service points for easy access. Factory-built power units allow for easy integration for generator set builders.

Total qualityEvery component of a John Deere engine is scrutinised for quality. The result: a generator drive engine that delivers performance, fuel efficiency, reliability, emissions compliance, and easy installation. We are ISO 9001 and 14001 certified, and we have expertise partnering with gen-set manufacturers worldwide.

Low cost of ownershipJohn Deere generator drive engines rarely need repair — going 500 hours or more before needing routine service. This, along with their impressive fuel efficiency, results in a low cost of ownership. It’s why John Deere has received the attention and loyalty of so many generator set manufacturers and customers.

Ready for results

Our engines are recognised for their exceptional power density, which results in smaller canopies and less weight on the trailer and on the road.

13505_PowerGen_StageIIIA_4pg_Brc_by_4c_8-5x11v.indd 2 12/11/12 8:00 AM

3

Features and benefits of the new Stage III A range

Nonroad mobile machinery constant speed engines emissions regulations 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015

2004

/26/

CE

EU

<18 kW 18 – 37 kW Stage II Stage III A37 – 56 kW Stage II Stage III A56 – 75 kW Stage II Stage III A

75 – 130 kW Stage II Stage III A130 – 560 kW Stage II Stage III A

>560 kW

High performance – High-pressure common rail system with electronic control and air-to-air after-cooling provides exceptional load acceptance

– Fan designed to minimise power consumption and maximise fuel efficiency

Ease of integration – Fan guard meets all latest European regulations

– Cooling package designed for enclosures up to 200 Pa air restrictions and 47°C ambient air temperature

– Front feet design includes cooling package mountings

Environmentally friendly – Higher fuel injection pressure and multiple injections reduce fuel consumption, noise, and vibration

– Clean engine environment with optional crankcase ventilation system (OCV)

– Low-noise fan design

RatingsEngine model

Rated speed Engine power standby Standby ratings Engine power prime Prime ratings Typical generator

efficiencyTypical fan

power GSPUrpm kW hp kVA kWe kW hp kVA kWe % kW

PowerTech M

3029TFG80 1500 31 42 32 – 34 26 – 27 28 38 29 – 31 24 – 25 88 – 92 1.3 3029TFU801800 35 47 35 – 37 28 – 30 32 42 32 – 34 26 – 27 88 – 92 2.2

3029HFG80 1500 41 55 43 – 45 35 – 36 37 50 39 – 41 31 – 33 88 – 92 1.4 3029HFU801800 46 62 48 – 50 38 – 40 42 56 43 – 45 34 – 36 88 – 92 2.4

4045HFG81 1500 61 82 67 – 70 53 – 56 56 75 61 – 63 48 – 51 88 – 92 2 4045HFU811800 65 87 69 – 73 56 – 58 59 79 63 – 66 50 – 53 88 – 92 3.4 PowerTech E

4045HFG82 1500 83 111 89 – 93 71 – 74 76 101 81 – 84 64 – 67 88 – 92 2 4045HFU821800 86 115 90 – 95 72 – 76 78 105 82 – 86 65 – 69 88 – 92 3.4

4045HFG82 1500 103 138 108 – 114 87 – 91 94 126 98 – 103 79 – 82 88 – 92 4 4045HFU821800 106 142 108 – 114 87 – 91 96 129 98 – 103 78 – 82 88 – 92 6.7

4045HFG82 1500 123 165 128 – 134 102 – 107 112 150 116 – 121 92 – 97 88 – 92 6 4045HFU821800 126 169 126 – 132 101 – 106 115 154 113 – 119 91 – 95 88 – 92 10.3

6068HFG82 1500 153 205 159 – 167 127 – 133 139 187 144 – 151 115 – 121 88 – 92 7.3 6068HFU821800 156 209 156 – 164 125 – 131 142 190 140 – 148 112 – 118 88 – 92 12.6

6068HFG82 1500 202 271 213 – 223 170 – 179 184 246 193 – 202 154 – 162 88 – 92 7.3 6068HFU821800 212 284 218 – 228 174 – 183 193 259 197 – 206 157 – 165 88 – 92 12.6

6090HFG84 1500 253 339 266 – 278 213 – 223 230 309 240 – 252 192 – 201 90 – 94 15.2 6090HFU841800 258 346 267 – 280 213 – 224 235 315 241 – 252 192 – 202 90 – 94 18.9

6090HFG84 1500 304 408 323 – 338 258 – 271 277 371 292 – 306 234 – 245 90 – 94 15.2 6090HFU841800 315 422 331 – 347 265 – 277 287 384 299 – 313 239 – 251 90 – 94 18.9

Ease of use – Dual frequency (50/60 Hz switchable); Stage III A/Tier 3 certified at both 1,500 and 1,800 rpm for most ratings

– See-through expansion tank for quick coolant level checks

– Easy modification of governing parameters in case

– Superior cold starting

High reliability and low maintenance – Heavy-duty air cleaner available for the most severe working environments

– Two-stage fuel filtration with water detection (from 80 to 300 kVA)

– Electronic system allows engine performances monitoring and easy diagnostics

– Replaceable cylinder liners for easy overhaul

– Optional belt tensioner eliminates need for manual adjustment

13505_PowerGen_StageIIIA_4pg_Brc_by_4c_8-5x11v.indd 3 12/11/12 8:01 AM

Easy access to parts and serviceWith more than 4,000 John Deere service locations worldwide, you never have far to go to find expert assistance and advice.

Simple maintenanceOur engines have extended oil change intervals — up to 500 hours. Single-side service points make it easy to check and maintain fuel filters, oil filters, starters, and fluid levels. Automatic belt tensioners minimise maintenance cost and increase belt life. Larger fuel filters, water separators, fuel pressure sensors, and fault code diagnostics optimise filter life.

Ready to provide customer support

Remanufactured componentsReduce operating downtime and repair costs with John Deere remanufactured engines and engine components. Our remanufactured components provide a high-quality, quick replacement at a lower cost.

Fast parts deliveryOur dealers stock maintenance parts, as well as many other common replacement parts to meet your service needs quickly. Our worldwide parts distribution system also provides overnight delivery in most regions.

A warranty you can count onFrom the day your gen-set begins operation, it’s warranted for uninterrupted service. We offer a 2-year/2,000-hour and 1-year/unlimited-hour warranty. Extended warranties are also available under certain conditions — up to 5 years/5,000 hours. Be sure to register your engine for warranty support.

Log on to www.JohnDeere.com/dealer to find the service dealer nearest you.

North America, South America, Brazil, and CaribbeanJohn Deere Power Systems3801 West Ridgeway AvenueP.O. Box 5100Waterloo, IA 50704-5100Phone: +1 800 533 6446 (U.S.)Phone: +1 319 292 6060 (Canada)Fax: +1 319 292 5075Email: [email protected]

Mexico and Central America Industrias John Deere S.A. de C.V.Boulevard Diaz Ordaz No. 500Garza Garcia, Nuevo Leon 66210MexicoPhone: +52 81 8288 1212Fax: +52 81 8288 8284Email: [email protected]

Europe, Africa, and Middle EastJohn Deere Power SystemsOrléans-Saran UnitLa Foulonnerie – B.P. 1101345401 Fleury-les-Aubrais CedexFrancePhone: +33 2 38 82 61 19Fax: +33 2 38 84 62 66Email: [email protected]

Australia and New Zealand John Deere LimitedPower Systems DivisionP.O. Box 1126, CamdenNSW 2570 AustraliaPhone: +61 2 4654 5501Fax: +61 2 4646 1236Email: [email protected]

Far EastJohn Deere Asia (Singapore) Pte. Ltd.#06-02/03 Alexandra Point438 Alexandra Road119958 SingaporePhone: +65 (68) 79 88 00Fax: +65 (62) 78 03 63Email: [email protected]

Worldwide locations

GenSet III A (13-01)

This literature has been compiled for worldwide circulation. While general information, pictures and descriptions are provided, some illustrations and text may include finance, credit, insurance, product options and accessories NOT AVAILABLE in all regions. PLEASE CONTACT YOUR LOCAL

DEALER FOR DETAILS. John Deere reserves the right to change specification and design of all products described in this literature without notice.

JohnDeere.com