Upload
others
View
11
Download
0
Embed Size (px)
Citation preview
GENSET PRODUCTS
201
3
TECHNOLOGY IS NOWFOR EVERYONE
D 700 COMMUNICATION CAPABILITIES
AUTOMATIC MAINS FAILURE UNITS
DKG 107DKG 107 The lowest cost AMF module
• Factory set timers• Adjustable AC low voltage limit• Jumper selectable 50/60Hz • Jumper selectable oil pressure/ oil level switch input• Dimensions: 72x72x52mm (WxHxD)
DKG 105DKG 105 Simple, compact & programmable
• Configurable from front panel• Digital display of genset frequency and phase voltages• Dimensions: 72x72x76mm (WxHxD)
DKG 207DKG 207 Low cost with analog measurements
• KW and PF measurement (single phase)• Periodic maintenance request display• Logic level serial port• Dimensions: 130x100x39mm (WxHxD
DKG 307
DKG 307 Wide temperature range & analog measurements
• Available with J1939 or MPU input• True RMS measurements• Genset KW and PF measurement• Battery backed-up real time clock,• Weekly operation schedule programs• Built-in daily, weekly, monthly exerciser• 100 event logs with time stamp and measurements• Statistical counters• Serial RS-232 port• MODBUS communications• Dimensions: 172 x 134 x 46 mm (WxHxD)
AUTOMATIC MAINS FAILURE UNITS
DKG 109DKG 109 Graphic display, 96x96mm
• J1939-CANBUS or magnetic pickup input• True RMS measurements• Multiple language support• Genset KW and PF measurement (single phase)• 100 event logs with time stamp and measurements• Logic level serial port• Dimensions: 102 x 102 x 53 mm (WxHxD)
DKG 309DKG 309 Basic, high performance & versatile
• J1939-CANBUS or magnetic pickup input• True RMS measurements• Multiple language support• Genset per phase KW and PF measurement• Battery backed-up real time clock,• Weekly operation schedule programs• Built-in daily, weekly, monthly exerciser• 100 event logs with time stamp and measurements• GSM SMS message sending on fault• Modem calls on fault• MODBUS communications• Dimensions: 172 x 134 x 46 mm (WxHxD)
D 300 Low cost, graphic display
• J1939-CANBUS or magnetic pickup input• True RMS measurements• Multiple language support• Genset per phase KW and PF measurement• 100 event logs with time stamp and measurements• Dimensions: 172 x 134 x 46 mm (WxHxD)
D 300
DKG 509DKG 509 High performance & versatile
• J1939-CANBUS or magnetic pickup input• True RMS measurements• Multiple language support• Genset per phase KW and PF measurement• Battery backed-up real time clock,• Weekly operation schedule programs• Built-in daily, weekly, monthly exerciser• 100 event logs with time stamp and measurements• GSM SMS message sending on fault• Modem calls on fault• MODBUS communications• Optional internal GSM modem• Dimensions: 200 x 148 x 46 mm (WxHxD)
ALL IN ONE UNITS
D 500D 500 The advanced controller technology is now for everyone !
The D 500 is a comprehensive genset controller capable of all possible functions and communications.
FUNCTIONALITIES• AMF & ATS controller with no-break transfer• Remote & Manual start controller• Remote display & control module
COMMUNICATIONS• Ethernet 10/100 mbits• Internal GPRS modem (optional)• Embedded web server for monitoring & programming• GSM-SMS sending• e-mail sending• RS-485 Modbus• Modbus TCP/IP• SNMP• USB Host (optional)• USB Device• RS-232 (optional)• Micro SD card slot (optional)
FEATURES• True RMS mains and genset AC measurements• Long term data recording on flash card• Waveform display of V & I• Harmonic analysis of V & I• Synchroscope display• 400 Hz enabled• J1939 CANBUS electronic engine support• Battery backed-up real time clock,• Built-in daily, weekly, monthly exerciser• Weekly operation schedule programs• Multiple language support• Customer logo display capability• 400 event logs with time stamp and measurements• Free PC software (USB-Modbus-IP Connected)• Free Central Monitoring through internet• Dimensions: 200 x 148 x 46 mm (WxHxD)
D 700
ALL IN ONE UNITS
D 700 One controller for all genset applications
The D 700 is a comprehensive genset controller capable of all possible functions and communications.
FUNCTIONALITIES• Multi genset synchronization and load share (48 gensets + 16 mains)• Multi genset parallel with mains• Multi genset power export to mains• Multi genset peak lopping (peak shaving)• Single genset parallel with mains• AMF & ATS controller with no-break transfer• Remote & Manual start controller• Remote display & control module
COMMUNICATIONS• Ethernet 10/100 mbits• Internal GPRS modem (optional)• Embedded web server for monitoring & programming• GSM-SMS sending• e-mail sending• RS-485 Modbus• Modbus TCP/IP• SNMP• USB Host (optional)• USB Device• RS-232 (optional)• Micro SD card slot (optional)• Fully isolated CANBUS multi-device DataLink
FEATURES• True RMS mains and genset AC measurements• Long term data recording on flash card• Waveform display of V & I• Harmonic analysis of V & I• Synchroscope display• 400 Hz enabled• J1939 CANBUS electronic engine support• Both active and reactive load sharing• G-59 mains protections• Heavy Duty Feature• Dead bus sensing• Load dependent quick and delayed automatic Start/Stop• Soft loading and unloading of gensets• Equal aging of gensets• Programmable Logic functions• Built-in Governor control• Fully isolated built-in AVR control• Battery backed-up real time clock,• Built-in daily, weekly, monthly exerciser• Weekly operation schedule programs• Multiple language support• 400 event logs with time stamp and measurements• Free PC software (USB-Modbus-IP Connected)• Free Central Monitoring through internet• Dimensions: 243 x 183 x 47mm (WxHxD)
PAR«A KODU: K20R02E
D 700
MAINS
GENSET
AUTO STOPMAN RUN TEST
ALARM
WARNING
SERVICEREQUEST
AUTOREADY
LOAD
A
A
PGM
PAR«A KODU: K20R02E
D 700
MAINS
GENSET
AUTO STOPMAN RUN TEST
ALARM
WARNING
SERVICEREQUEST
AUTOREADY
LOAD
A
A
PGM
4.3” TFT DISPLAY VERSION
: Optional
AMF SELECTION CHART
DKG
10
5
DKG
10
7
DKG
20
7
DKG
30
7
DKG
10
9
DKG
30
9
DKG
50
9
D 3
00
D 5
00
D 7
00
3 3 3 3 3 3 3 3 3 3
1 1 1 3 1 3 3 3 3 3
1 3 1 3 3 3 3 3
2 2 2 2 2 2 2 2 2
3 2 4 4 4
4 4 4 6 8
2 2 5 7 5 7 7 7 8 12
2 4 3 4 4 4 4 7
100 100 100 100 100 400 400
Support
Customer
DKG 090 GSM-GPRS MODEM Internet on air
• Designed for harsh automotive environment• DC 8-36V power supply with protection• DIN Rail mounted• Lock-up free operation with D-xxx models• Connects to all Datakom models• GPRS Class 10 communications
DKG 210DKG 210 Your flexible gateway to fleet management
• Connects to Rainbow Scada through ethernet and GPRS• Connects all Datakom modules to Rainbow Scada• Ready to connect all 3rd party products to Rainbow Scada• Connects up to 16 endpoints through RS-485 Modbus• GSM_SMS and E-Mail sending• Designed for harsh automotive environment• DC 8-36V power supply with protection• Optional AC 230V power supply• Internal GSM-GPRS modem• RS-485 port• RS-232 port• CANBUS port• USB Host port• USB Device port for configuration• Free Rainbow Plus configuration program
REMOTE FLEET MANAGEMENT
RAINBOW SCADA Your fleet is on your desktop!
Rainbow Scada is an internet based universal remote monitoring and control program, flexible enough to integrate all kinds of intelligent control modules, independently of the manufacturer and function.
• Monitors up to 30’000 endpoints• Free of charge up to 100 endpoints• Provides data security, data is sent to your IP address only• Uses internet based dynamic world map• On-line display of endpoint statuses on map and side bar• Hierarchical structuring and grouping of endpoints• Remote control of endpoints• Recognizes automatically all Datakom D-xxx models• Supports all Datakom products through DKG-210 gateway• Supports 3rd party Modbus enabled products through DKG-210 gateway• Data recording and analysis• HTML interface for web monitoring
DKG 090
RAINBOW SCADA
DKG 090
GPRSMODEM
SIMCARD
GGC
BSUPPLY8-36 V-DC
RS 232
DKG 090
GPRSMODEM
SIMCARD
GGCBSUPPLY
8-36 V-DC
RS 232
IN-1
IN-2
G NEU
T
GC
B L
GN
DHRS 485
GN
D 1 2
RS 232
USB
UNIVERSALINTERNETGATEWAY
DKG 210
IN-1
IN-2
GNEUT
GCB L
GNDHRS 485
GND 1 2
RS 232
USB
UNIVERSALINTERNETGATEWAY
DKG 210
DKG 114DKG 114 Basic, zero power at rest
• Charge alternator excitation circuit, charge fail protection• Jumper selected options for cooldown, 50/60Hz and Aux relay• Selectable engine running signal (from genset AC or charge alternator)• Dimensions: 72x72x43mm (WxHxD)
DKG 116DKG 116 The lowest cost Remote Start module
• Suitable for gasoline and diesel gensets.• True RMS measurements• Tamper proof engine hours display• Dimensions: 102 x 55 x 40 mm (WxHxD)
DKG 215DKG 215 Basic with measurements, zero power at rest
• Genset KW and PF measurement• Engine hours run counter• Periodic maintenance request display• Statistical counters• Dimensions: 102 x 102 x 53mm (WxHxD)
DKG 227DKG 227 Basic with measurements, zero power at rest
• Genset KW and PF measurement• Engine hours run counter• Periodic maintenance request display• Statistical counters• Dimensions: 130x100x39mm (WxHxD)
DKG 317DKG 317 Wide temperature range & analog measurements
• Available with J1939 or MPU input• True RMS measurements• Genset KW and PF measurement• Battery backed-up real time clock• Weekly operation schedule programs• Built-in daily, weekly, monthly exerciser• 100 event logs with time stamp• Statistical counters• Serial RS-232 port• MODBUS communications• Dimensions: 172 x 134 x 46 mm (WxHxD)
MANUAL AND REMOTE START UNITS
DKG 119DKG 119 Graphic display, 96x96mm
• J1939-CANBUS or magnetic pickup input• Genset KW and PF measurement (single phase)• 100 event logs with time stamp and measurements• Logic level serial port• Dimensions: 102 x 102 x 53 mm (WxHxD)
DKG 319DKG 319 Basic, high performance & versatile
• J1939-CANBUS or magnetic pickup input• True RMS measurements• Multiple language support• Genset per phase KW and PF measurement• Battery backed-up real time clock,• Weekly operation schedule programs• Built-in daily, weekly, monthly exerciser• 100 event logs with time stamp and measurements• GSM SMS message sending on fault• Modem calls on fault• MODBUS communications• Dimensions: 172 x 134 x 46 mm (WxHxD)
DKG 519DKG 519 High performance & versatile
• J1939-CANBUS or magnetic pickup input• True RMS measurements• Multiple language support• Genset per phase KW and PF measurement• Battery backed-up real time clock,• Weekly operation schedule programs• Built-in daily, weekly, monthly exerciser• 100 event logs with time stamp and measurements• GSM SMS message sending on fault• Modem calls on fault• MODBUS communications• Optional internal GSM modem• Dimensions: 200 x 148 x 46 mm (WxHxD)
D 300-RSD 300-RS (Remote Start) Low cost, graphic display
• J1939-CANBUS or magnetic pickup input• True RMS measurements• Multiple language support• Genset per phase KW and PF measurement• 100 event logs with time stamp and measurements• Dimensions: 172 x 134 x 46 mm (WxHxD)
MANUAL AND REMOTE START UNITS
MANUAL AND REMOTE START SELECTION CHART
DKG
11
4
DKG
11
6
DKG
21
5
DKG
22
7
DKG
31
7
DKG
11
9
DKG
31
9
D 3
00
-RS
D 5
00
DKG
51
9
D 7
00
1 3 1 3 3 1 3 3 3 3 3
1 1 3 1 3 3 3 3 3
2
3 2 4 4 4 4
1 4 4 4 6 8
3 4 5 5 7 5 7 7 7 8 12
3 2 4 3 4 4 4 4 7
100 100 100 100 100 400 400
Customer
Support
: Optional
MANUAL START UNITS
REMOTE START UNITS
DKG 110DKG 110 Low cost engine protection
Provides engine protection functions in a manual control panel• DIN rail mounted• 10 Amp fuel and alarm relay outputs• High engine temperature & low oil pressure switch inputs• Overspeed-underspeed protection• 3 semiconductor lamp outputs• Generator phase voltage input• Standard dimensions, 36mm width
DKG 151DKG 151 Low cost manual start unit
• 10 Amp fuel and crank relay outputs• Charge alternator excitation circuit , charge fail protection• High engine temperature & low oil pressure switch inputs• Overspeed-underspeed protection• Spare alarm input• User selectable 50/60 Hz & energize to start/stop operations• Dimensions: 72x72x38mm (WxHxD)
DKG 155DKG 155 Manual start with high current outputs
• 16 Amp fuel and crank outputs• Charge alternator excitation circuit , charge fail protection• High engine temperature & low oil pressure switch inputs• Overspeed-underspeed protection• Spare alarm input• User selectable 50/60 Hz operation• Dimensions: 72x72x52mm (WxHxD)
DKG 152DKG 152 Low cost remote start unit
• 10 Amp fuel and crank relay outputs• Charge alternator excitation circuit , charge fail protection• High engine temperature & low oil pressure switch inputs• Overspeed-underspeed protection• Cooldown cycle on remote start operation• User selectable 50/60 Hz operation• User selectable energize to start/stop operation• Dimensions: 72x72x38mm (WxHxD)
MANUAL SYNCHRONIZATION
GOVERNOR CONTROLLERS
DKG 117DKG 117 Synchroscope & check synch unit
• 16 Amp check synch relay output• Adjustable ∆V, ∆F, ∆theta for check synch• Single phase genset & busbar voltage inputs• Synch Check Enable input• Dead Bus Enable input• Auto power_off feature• Front panel adjustable parameters• Dimensions (72x72x52mm)
DKG 217DKG 217 Auto start module with synchroscope & check synch
• Zero power consumption at rest• 16 Amp check synch relay output• Adjustable ∆V, ∆F, ∆theta for check synch• Genset / busbar voltage inputs: 3 /1• Genset current input: 1• Analogue temperature and oil pressure inputs• Configurable digital inputs: 5• Genset KW and PF measurement (1 phase)• Periodic maintenance request indicator• Configurable from front panel• Engine hours run counter• Serial data port for telemetry on PC• Dimensions (130x100x39mm)
DKG 253DKG 253 Governor controller with ramp and speed protection
• 12 and 24V operation• 10 Amp continuous current output• Fast and accurate response• Isochronous and droop operation• Forward acting actuator output• Starting fuel & speed ramp adjustments• Overspeed alarm output• Adjustable rated and idle speeds• External speed adjustment input• Speed sensor failure detection• Battery reverse voltage protection• Output short circuit protection• Dimensions (130x110x27mm)
DKG 727 Basic mains synchronization unit
• Multi genset soft transfer to / from mains• Multi genset power export to mains• Multi genset peak lopping (peak shaving)• Heavy Duty Feature• True RMS mains and busbar AC measurements• G-59 mains protections• Programmable Logic functions• Fully isolated datalink communication port• Battery backed-up real time clock• Built-in daily, weekly, monthly exerciser• 500 event logs with time stamp and full snapshot• Weekly operation schedule programs• Free MS-Windows Remote monitoring SW• Isolated RS-485 MODBUS Support throughoptional USB adaptor• Output expansion capability• Dimensions: 235 x 167 x 48mm (WxHxD)
HMI 7000HMI 7000 Display gloriously
• 7 inch 800x480 pixels color TFT LCD Touch Screen Panel• RS232 and RS485(2w/4w) connections• Multiple gensets within the same load sharing system can be viewed• Configurable kW and kVAr trend records• Configurable gauge limits• Compatible with all LCD display Datakom models• Built-in flash memory and Real Time Clock• USB Host port for mouse and keyboard connection• USB device port for PC connection• User programmable with free Scada based software• NEMA4/IP65 compliant front panel• Dimensions: 200 x 146 x 42.5mm
MULTI GENSET PARALLELING UNITS
DKG 707 Basic multi-genset synchronization and load share unit (up to 8 gensets)
• Both active and reactive load sharing• J1939 CANBUS electronic engine support• True RMS genset and busbar AC measurements• Built-in Governor control• Fully isolated built-in AVR control• Fully isolated data link communication port• Soft loading and unloading of gensets• Equal aging of gensets• Programmable Logic functions• Battery backed-up real time clock• Built-in daily, weekly, monthly exerciser• Weekly operation schedule programs• 500 event logs with time stamp and full snapshot• Free MS-Windows Remote monitoring software• Isolated RS-485 MODBUS Support through optional USB adaptor• Output expansion capability• Dimensions: 235 x 167 x 48mm (WxHxD)
DKG 727
DKG 707
AUTOMATIC TRANSFER SWITCHES
DKG 329
DKG 329 High Performance ATS controller
• True RMS measurements• Synch check and no-break transfer• Mains / genset voltage inputs: 3 / 3• Load current transformer inputs: 3• Digital inputs: 7• Digital outputs: 6• Multiple language support• 3 level password support• Load KW and PF measurement• Battery backed-up real time clock,• Weekly operation schedule programs• Built-in Daily / weekly / monthly exerciser• 100 event logs with time stamp and measurements• GSM SMS message sending on fault• Modem calls on fault• MODBUS communications• Dimensions: 172 x 134 x 46 mm (WxHxD)
DKG 171DKG 171 The basic ATS controller
• Provides Remote Start signal for engine controller• Mains / genset voltage inputs: 3 / 1• Relay outputs: MC, GC, remote start• Factory set timers• Adjustable mains and genset low limits• Genset test mode available• Dimensions: 72x72x38mm (WxHxD)
DKG 173DKG 173 DIN Rail ATS controller without DC supply
• Provides Remote Start signal for engine controller• Mains / genset voltage inputs: 3/ 1• 16Amp MCB, GCB and remote start output• Adjustable MCB and GCB delays• Isolated mains and genset inputs• Installation: DIN Rail mounted.• Dimensions: 70x115x66mm (WxHxD)
123 / 124 / 125 /1210 / 242 / 243 / 245 / 2410
BATTERY CHARGERS
SMPS
• SMPS series are fixed output voltage, current limited lead acid battery chargers specially designed for permanent connection to genset starter batteries. They maintain the batteries fully charged, without overcharging or gassing. • The chargers are designed in switchmode technology. Their rugged design allows surviving in harsh electromagnetic environments found in automotive industry.• The low weight of the unit makes it ideal for use in highly vibrating generator control panels. The small dimensions allow compact panel design.• Thanks to their high efficiency, the self- heating of the chargers is kept in minimum levels allowing operation in warm environments.• 100 KHz switchmode architecture,• Float charging system,• Constant voltage output,• Current limited,• Rugged design for industrial environments,• Rectifier fail output• Boost charge input• Short circuit protection• Overload protection• High temperature protection• Plug-in connection system• Output voltage and current display option• Operating voltage range: 170-270 VAC• Operating frequency range: 45-65 Hz• Operating temp range: -20 to +70 °C
DIN RAIL MOUNTED
volts
amps
13.7
3
13.7
5
13.7
10
27.4
3
27.4
5
27.4
10
13.7
4
27.4
2
SMPS-123 SMPS-125 SMPS-1210 SMPS-243 SMPS-245 SMPS-2410SMPS-124DIN RAIL
SMPS-242DIN RAIL
DC GENSET CONTROLLERS
EARTHQUAKE DETECTOR UNITSDSD 050
DSD 050 Earthquake Shut-off System
The DSD-050 is an earthquake shut-off system based on micromachined polysilicon acceleration sensors• Direct connection to electromechanical solenoid valves• Internal 12Vdc battery and battery charger• Seismic properties conformal to ANSI Z.21-70 (1981) and ASCE 25-97• Non-seismic accelerations filtered• Capable of performing self-test• Maintenance free
DSD 060DSD 060 Earthquake Detector
Based on micromachined polysilicon acceleration sensors, the DSD-050 detects seismic acceleration and generates control signals to shutdown any critical devices.• Seismic properties conform to ANSI Z.21-70 and ASCE 25-97• Non-seismic accelerations filtered• Capable of performing self-test • Maintenance free• Standard and high sensitivity detection relay outputs• Operates on 10 to 30 volts DC• Resin molded design
DKG 379DKG 379 The intelligent DC genset controller
• Controls charge voltage, charge current and engine rpm dynamically in order to match the exact required value.• İntelligent charging algorithm, provides longer battery life• 7A-DC power drive output • ECU connection through J1939-CANBUS option• 0-10V analog control output• Compatible with 24V and 48V systems• Battery temperature input for PT100 sensor• Multiple language support• Dual genset mutual standby operation• Battery backed-up real time clock• Built in daily / weekly / monthly exerciser• 100 event logs with time stamp and measurements• GSM SMS message sending on fault• Modem calls on fault• MODBUS communications• Dimensions: 172x134x76mm
AUTO STOPTEST RUN
DKG 379
LOAD
GENSET
WARNING
SERVICEREQUEST
PGM
STATUS
ALARM
A
AUTO STOPTEST RUN
DKG 379
LOAD
GENSET
WARNING
SERVICEREQUEST
PGM
STATUS
ALARM
A
ALTERNATOR VOLTAGE REGULATORS
Dimensions: 126x68x35mm
AVR 40
Dimensions:133x98x82mm
AVR 8
Dimensions:133x98x35mm
AVR
5
AVR
12
AVR
20
AVR
8
AVR
8-3
80
AVR
40
Half wave thyristor output
Continuous output current
Minimum voltage input (VAC)
Maximum voltage input
Max output voltage @230VAC L-N
Volt adjust potentiometer
Remote voltage trimmer input
Stability adjustment potentiometer
50 / 60 Hz compatible
Low frequency protection
Analog volt adjust input for load share
CT input for droop operation
Output overload protection
High temperature protection
Voltage sensing loss protection
Adjustable output overload limit (opt)
Isolated sensing voltage input
5A 10A 20A 8A 8A
190 190 190 190 330
260 260 260 450 470
115V 115V 115V 115V 200V
40A
190
450
115V
AVR 20AVR 12AVR 5
DATAKOM Electronics Limited Tel: + 90-216 466 84 60 Fax: + 90-216 364 65 65 e-mail: [email protected] http://www.datakom.com.tr