42
Field Application Version 8.095

Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

  • Upload
    others

  • View
    15

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

Field Application Version 8.095

Page 2: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

Geotab - Field Application – Version 8.095 User Guide Warning: The Geotab application and this manual are protected by copyright laws and by international conventions. Any reproduction or distribution of the application or its manuel, partially or totally, by any means, is strictly forbidden, unless a written permission is given by SOBEK TECHNOLOGIES INC. Any person who does not respect these rules is guilty of a misdemeanour of infringement and is punishable by law. Published by: SOBEK TECHNOLOGIES INC. 4205 Northcliffe Montreal (Quebec) H4A 3L2 Phone : 514 285-4873 Email : [email protected] The information in this manuel can be modified without notice and would not be binding to SOBEK TECHNOLOGIES INC. This version of the documentation was updated in August 2019 with version 8.095 of Geotab. TRADEMARKS: In this guide, we refer to these registered products: Access is a registered trademark of Microsoft Corporation Oracle is a registered trademark of Oracle Corporation SQLite is public domain SQL Server is a registered trademark of Microsoft Corporation Windows is a registered trademark of Microsoft Corporation

Page 3: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

Geotab - Table of contents i

2019-08-21 l:\english\geotec\geotab\809\geotab_toc_eng.doc

GEOTAB - TABLE OF CONTENTS

______________________________________________________________________

LIST OF FIGURES iv

LIST OF TABLES iv

Geotab - Field application 1

1. Installation 1 1.1. Requirements for Geotab 1

2. Licences 1 2.1. Obtaining a licence 1 2.2. Activate a licence 2 2.3. Reactivate a licence 2

3. Creation of Geotab folders and files 2 3.1. Replace existing files 3

4. Boring log 3 4.1. Licence 3 4.2. Moving and zooming 4 4.3. SITE query 4 4.4. BORING query 4 4.5. List of forms 4

4.5.1. Opening the forms via the boring log 5 4.6. Options menu 5

4.6.1. Open DB 5 4.6.2. Open style 5 4.6.3. Open markers 6 4.6.4. Open patterns 6 4.6.5. Open logo 6 4.6.6. Create project 6 4.6.7. Export project 7 4.6.8. Generate report 8 4.6.9. Reinstall Geotec 8 4.6.10. Parameters 8 4.6.11. About 10

5. Entry forms 10 5.1. Information in the title bar of the entry forms 10

5.1.1. Home and back 10 5.1.2. Site and boring numbers 10 5.1.3. Number of records 10

5.2. Options in the title bar of the entry forms 11 5.2.1. Gmap (Beta version) 11 5.2.2. GPS location 11 5.2.3. QR Code (Beta version) 11 5.2.4. Add layer 11 5.2.5. Observations 11

Page 4: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

ii Geotab - Table of contents

2019-08-21

5.3. Options menu of the entry forms 11 5.3.1. Complete form 11 5.3.2. Delete record 11 5.3.3. Cancel 12 5.3.4. Select fields 12 5.3.5. Units of depths 13 5.3.6. Units of lengths 13

5.4. Button bar of the entry forms 13 5.4.1. Previous 13 5.4.2. Save 14 5.4.3. Insert 14 5.4.4. Drawing 14 5.4.5. Photo 15 5.4.6. Next 15

5.5. Generalities of the forms 15 5.5.1. Swiping 15 5.5.2. Required values 15 5.5.3. Lists in date fields 15 5.5.4. Lists of values 15 5.5.5. Tables 16 5.5.6. Default values 16

6. SITE form 17

7. BORING form 18 7.1. Generalities 18 7.2. Water table 20 7.3. Insert new boring 20 7.4. Casings 20 7.5. Trench 21

8. SAMPLE form 22 8.1. Remoulded 23 8.2. Undisturbed 24 8.3. Rock core 24 8.4. Sub-samples 24

9. STRATIGRAPHY form 24

10. Selection matrix 26 10.1. Duplicate previous 26 10.2. Selection of materials 26

10.2.1. Fill 26 10.2.2. Scrolling list of materials 26 10.2.3. Simplified classification 26 10.2.4. Presence 26 10.2.5. Code and proportion 26

10.3. Color 26 10.4. Compaction or consistency 27 10.5. Moisture 28 10.6. Description 28 10.7. Exit 28

11. Automatic creation of layers 28

12. VANE TEST form 29

13. PEN TEST form 30

14. PIEZOMETER form 31

Page 5: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

Geotab - Table of contents iii

2019-08-21

14.1. Open tube 32 14.2. Pneumatic 32 14.3. Electric 32 14.4. Seals 33 14.5. Levels 33

15. OBSERVATION dialog box 34

16. MORE TABLES form 34 16.1. Query form 35

Page 6: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

iv Geotab - Table of contents

2019-08-21

LIST OF FIGURES

Figure 1 – Creation of Geotab folders and files 3

Figure 2 – Replace existing files 3

Figure 3 – Toolbar of the boring log 3

Figure 4 – Options menu of the boring log 5

Figure 5 – Creation of a new project 7

Figure 6 – Export a project 8

Figure 7 – Parameters 9

Figure 8 – Top of the entry forms 10

Figure 9 – Options menu of the entry forms 12

Figure 10 – Selection of fields 13

Figure 11 – Creation of drawings 14

Figure 12 – Adding values in the lists 16

Figure 13 – SITE form 17

Figure 14 – BORING form - Information 19

Figure 15 – CASINGS form 21

Figure 16 – TRENCH form 21

Figure 17 – SAMPLE form 23

Figure 18 – STRATIGRAPHY form 25

Figure 19 – Selection matrix 27

Figure 20 – VANE TEST form 29

Figure 21 – PEN TEST form 30

Figure 22 – PIEZOMETER form - Open tube and Seals 31

Figure 23 – PIEZOMETER form - Electric and Levels 33

Figure 24 – OBSERVATION dialog box 34

Figure 25 – MORE TABLES form 35

Figure 26 – Query conditions 36

LIST OF TABLES

Table 1 - Types of borings in Geotec 18

Table 2 - Types of samplers in Geotec 22

Page 7: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

Geotab - Field application 1

Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc

GEOTAB - FIELD APPLICATION

Geotab is used for the entry and validation of boring data directly on the field, on Android tablets. The data are saved in Geotec databases of SQLite type (.db3). The .db3 databases can be read directly in one of the Geotec modules or exported to Geotec databases under Access (.mdb), SQL Server or Oracle via the DBM module. Geotab is the ideal application to save transcription time, to avoid transcription errors and to do a preliminary validation to ensure that all boring data are complete before leaving the field.

1. INSTALLATION

1) Copy the file Geotab.apk on your tablet.

2) In the tablet settings, under Security, activate the option “Unknown sources - Allow the installation of apps from sources other than Play Store or Galaxy Apps”.

3) Start the installation of Geotab.apk by selecting its icon.

4) Once the installation is done, select Open.

5) Allow Geotab to access the device’s storage.

6) Allow Geotab to access the device’s location.

7) Obtain and activate your licence. See paragraph 2.

1.1. Requirements for Geotab

• Geotab requires version 4.0 or more recent of Android.

• Geotab is optimized for 10" or 7" tablets.

• Geotab is optimized for a font size up to ‘normal’.

• Version 8.08 or more recent of Geotec is required on Windows to export data from the .db3 databases or to read them directly in the modules.

2. LICENCES

Geotab requires a licence - unique to each tablet. Licences are available for a period of 1 month to 1 year and can be renewed.

2.1. Obtaining a licence

• Select ‘Obtain a licence’.

• Select ‘Send by email’ and fill out the requested information in the email that opens: Name, Company, Division, Email and Phone number.

• Sobek will contact you in the next 24 hours to confirm the acquisition.

• You can also send the identification to [email protected] or by phone at 514 285-4873.

Page 8: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

2 Geotab - Field application

2019-08-21 Creation of Geotab folders and files

2.2. Activate a licence

Sobek will send you an email as soon as the licence can be activated.

• Open Geotab.

• Select ‘Activate my licence’. You must be connected to Internet to activate the licence. If Internet is not available, we will provide you a code to enter manually.

• The licence will be activated for 1 month from the activation date. The activation due date is indicated. The licence must be activated within the purchased period of Geotab.

• Select OK. Geotab will restart.

2.3. Reactivate a licence

For licences with duration of more than one month, the licence must be reactivated each month, up until renewal. The Licence button located in the toolbar of the boring log (see Figure 3) is used to display information about the licence. From 7 days before the activation due date, this button displays the number of days remaining. The button ‘Reactivate my licence’ in the dialog box becomes active and the licence can be reactivated for the next month.

• The first date indicates until when the licence has been activated and the number of days remaining before having to reactivate.

• The second date indicates until when the licence is valid, that is, until when it was purchased. After that date, the licence must be renewed with Sobek.

• The tablet’s identification is also shown.

3. CREATION OF GEOTAB FOLDERS AND FILES

At the first use of Geotab, a dialog box (see Figure 1) is displayed to create the folders and files required for the full use of Geotab.

• The Geotec folder and its data, style, export and import subfolders will be located by default under /storage/emulated/0. This directory can be changed by selecting ….

• The French and English boxes are used to select the language of the files. By default, the tablet language is checked. If both languages are selected, the files in the current language will be opened the first time.

• The Template files box cannot be unchecked. The files included are:

Two style files; one specific to boreholes, the other to trenches

The patterns file Geotec8.ptn

The markers file Geotec8.mrk

These files are saved in the style folder. The borehole style and the other two files open automatically after the creation.

• The Database box cannot be unchecked. The file included is:

The Geotec_en.db3 database (and / or Geotec_fr.db3 in French).

This database is saved in a directory of the same name, under the data folder. It is automatically connected after its creation.

Page 9: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

Geotab - Field application 3

Boring log 2019-08-21

• Select Create to create the folders and files. A confirmation is displayed.

Figure 1 – Creation of Geotab folders and files

3.1. Replace existing files

If files of same name already exist in the Geotec directory, a dialog box is displayed to select the files to replace by the default files of Geotab.

Figure 2 – Replace existing files

4. BORING LOG

The boring log is Geotab’s home screen. Its toolbar, shown in Figure 3, is described below.

Figure 3 – Toolbar of the boring log

4.1. Licence

The Licence button opens a dialog box with information about the licence. See paragraph 2.3.

Page 10: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

4 Geotab - Field application

2019-08-21 Boring log

4.2. Moving and zooming

The Zoom button opens a menu with six choices.

• Full width: the log takes up the entire width of tablet, whether in portrait or landscape mode

• Full height: the log takes up the entire height of tablet, whether in portrait or landscape mode

• Zoom 50%: the log is 2x smaller than on paper

• Zoom 100% : the log has the same dimensions as on paper

• Zoom 200% : the log is 2x bigger than on paper

• Zoom 400% : the log is 4x bigger than on paper The last zoom selected is used when opening another style file or at the next use of Geotab. When the log is not shown entirely in width and / or height, it is possible to move it by touching the log with the stylus or 1 finger and moving as desired. It is also possible to adjust the zoom of the boring log by moving two fingers closer together or farther apart. The display in bitmap mode (see paragraph 4.6.10.3) is more effective for moves and zooms.

4.3. SITE query

The Site query button opens a dialog box showing all the sites defined in the connected .db3 database. By selecting a site, the log is reset and the site number is written in the toolbar of Geotab, above the DB name. The + NEW value is used to create a new site. The Site form is then opened and a dialog box asks for the site number. See paragraph 6 for the details about Site.

4.4. BORING query

The Boring query button opens a dialog box showing all the borings of the site selected defined in the connected .db3 database. By selecting a boring, the log is displayed and the boring number is written next to the site number in the toolbar of Geotab, above the DB name. If a site has not been selected, the list of borings shows those of all the sites in the DB. The + NEW value is used to create a new boring. The Boring form is then opened and a dialog box asks for the boring number. See paragraph 7 for the details about Boring.

4.5. List of forms

The List of forms button opens a menu with the choice of all entry forms of Geotab. By clicking one of the items, the corresponding form opens, showing the existing data or showing an empty form if no data has been inserted before. See paragraphs 6 to 16 for all details about each form. If no site has been selected, selecting any form opens the Site form to create one. Similarly, if no boring has been selected, selecting any form opens the Boring form to create one.

Page 11: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

Geotab - Field application 5

Boring log 2019-08-21

4.5.1. Opening the forms via the boring log

The forms can be opened directly by touching with a finger the desired column of the boring log. The corresponding form opens on the information touched. To open Site, touch the log header. To open Boring, touch the depth column.

4.6. Options menu

The options menu of the boring log shown in Figure 4 opens with this button.

Figure 4 – Options menu of the boring log 4.6.1. Open DB

With the option Open DB, the user navigates to the directory containing the desired .db3 database on the tablet and selects it. Geotab then opens this DB, whose name is indicated in the toolbar of Geotab above the boring log. The site and boring numbers are reset and the boring log is emptied. The Geotec_en.db3 database is created at installation in the directory of the same number, under data. When Geotab is opened, the application automatically connects to the last DB used. If the version of the database been opened is not up to date (SYS_USER), the database is updated automatically to the latest version. A message is displayed for every change made to the database. 4.6.2. Open style

With the option Open style, the user navigates to the directory containing the desired .sty style file on the tablet and selects it. Geotab then opens this style file. As soon as a query is done, the information is displayed in the corresponding columns.

Page 12: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

6 Geotab - Field application

2019-08-21 Boring log

The style files can be created in Geotec on Windows and copied on the tablet. Two styles are created at installation under the style directory, Borehole.sty and Trench.sty. When Geotab is opened, the application automatically connects to the last style file used. 4.6.3. Open markers

With the option Open markers, the user navigates to the directory containing the desired .mrk markers file on the tablet and selects it. When a markers file is opened, any column displaying curve points will show the designated marker of the style file. If no markers file is selected, the values of the curve points will still be present. The Geotec8.mrk markers file is created at installation. Markers files used in Geotec can also be copied on the tablet. When Geotab is opened, the application automatically connects to the last markers file used. 4.6.4. Open patterns

With the option Open patterns, the user navigates to the directory containing the desired .ptn patterns file on the tablet and selects it. When a patterns file is opened, any column showing filling pattern will display the pattern designated by the style file or the data. If no patterns file is selected, the data will be displayed textually. The Geotec8.ptn patterns file is created at installation. Patterns files used in Geotec can also be copied on the tablet. When Geotab is opened, the application automatically connects to the last patterns file used. 4.6.5. Open logo

With the option Open logo, the user navigates to the directory containing the desired image file on the tablet and selects it. If an image designated by $$logo is present in the style file used, the logo file is displayed. When Geotab is opened, the application automatically connects to the last logo file used. 4.6.6. Create project

The Create project option opens the following dialog box (see Figure 5).

The database to copy to create the new project can be:

• The empty default Geotec.db3 database, which contains all the tables and fields as well as typical values for the lists of data.

With an English or French dictionary

• Any other Geotec database, customized based on the needs (see paragraph 5.3.4).

Open the database with the … button.

The complete path will be indicated in the field next to Other. In the section Project to create:

• Enter the name of the new project.

• A subfolder with the same name will be created in the data directory.

• This subfolder will contain the database with the same name.

Page 13: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

Geotab - Field application 7

Boring log 2019-08-21

If the option Connect to new project is checked, Geotab will automatically connect to the new database after restarting Geotab.

Figure 5 – Creation of a new project 4.6.7. Export project

With the Export project option, the user can export a zip file containing a project’s directory, with the database, photos, drawings and log reports. Under Project to export, the list presents all folders in the data directory of Geotec. The current project is suggested by default. The path is indicated below the project name. Only one project can be exported at once. When the box Include name of parent folder is checked, the zip file includes the parent folder, with all its files inside. When the box isn’t checked, the zip file includes the files only. The zip file can be exported to an FTP or FTPS (implicit TLS) account or to an Email account, depending on the radio button selected. In the FTP or FTPS (implicit TLS) account section, all values must be entered.

• Host: enter the domain name

• Host directory: enter the directory where the zip files will be exported to

• Port: enter the port

• Login: enter the username

• Password: enter the password In the Email account section, enter the destination email. To keep the connection parameters, select the box at the bottom of the window. The password will be hidden.

Page 14: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

8 Geotab - Field application

2019-08-21 Boring log

Figure 6 – Export a project When you touch Export, the zip file is created and saved in the export directory under Geotec. The zip file is named Project-date-time.zip. The same zip file can be exported several times via FTP, FTPS or email while the window remains open. 4.6.8. Generate report

With the Generate report option, a PDF file of the current boring log is created and saved in the project directory. The file is named SITE_BORING_date-time.pdf. For Android versions 4.4 or older, a PNG file is generated. By checking the box Send by email, applications available on the tablet will be suggested to send the generated boring report. 4.6.9. Reinstall Geotec

The option Reinstall Geotec opens the Creation of Geotab folders and files, as shown in Figure 1. All default template files (see paragraph 3) can be recreated. 4.6.10. Parameters

The Parameters option opens the window shown in Figure 7.

Page 15: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

Geotab - Field application 9

Boring log 2019-08-21

Figure 7 – Parameters 4.6.10.1. Language

All menus, options, messages and labels of Geotab can be displayed in French, in English or automatically in the language set in the tablet (default option). If the tablet’s language is neither English nor French, English will be used.

4.6.10.2. Orientation

The application can be forced in Portrait mode, Landscape mode or can change orientation automatically (default option). 4.6.10.3. Bitmap mode

With the display in bitmap mode, an image of the log is taken. Moving and zooming on the boring log is faster. This is the default mode. If the display in bitmap mode is not activated, the report is redisplayed after each move or zoom. The resolution of the log is greater but the display is slower. 4.6.10.4. Field format

With the display of the field format, each field in the entry forms without a value will show in gray the format of the values to enter. If the box is not checked, the fields without value will be completely empty. Some examples:

t(6) text with 6 characters maximum

N(3) integer with 3 figures maximum

N(7.3) decimal number of 9999.999 maximum value (7 figures including 3 decimals)

N(.3e) number with 3 decimals in scientific format. Enter the value in decimal numbers; it will be converted to scientific format

D(YYYY-MM-DD HH:MM) date with its format

4.6.10.5. Depth scale

Page 16: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

10 Geotab - Field application

2019-08-21 Entry forms

The depth scale for the boring report can be imposed by the user, or the one of the style file (default option). The scale of the style file is indicated in parentheses next to the label. 4.6.10.6. Automatic calculation of X and Y coordinates

When the automatic calculation is checked, the calculation of the easting (X), northing (Y) and zone is done when the GPS location button is touched in the Boring entry form. Otherwise, only the longitudes and latitudes are retrieved by touching the location button. See paragraph 7.1. 4.6.11. About

About opens a dialog box with information about the version of Geotab. The files connected are also indicated.

5. ENTRY FORMS

Each data form contains a title bar as a button bar just below (see Figure 8). The name of the form is indicated on the right side of the button bar.

Figure 8 – Top of the entry forms

5.1. Information in the title bar of the entry forms

5.1.1. Home and back

The home button automatically saves data that were inserted or modified and returns to the log, which shows the changes. The back button of the tablet has the same function. If the changes cannot be saved, for example if a required data is not entered or if saving would create a duplicate, a message is displayed. You can either correct the data or cancel the modification (see paragraph 5.3.3). 5.1.2. Site and boring numbers

The current site and boring numbers are indicated in the title. All changes are done for this boring. To modify the data of another boring, you must select it from the toolbar of the boring log (see paragraphs 4.3 and 4.4). If the boring has not been selected yet, the Site form only shows the site number. Opening any other form requires the creation of a boring. 5.1.3. Number of records

In the SAMPLE and PIEZOMETER forms, the total number of samples or piezometers in the current boring is indicated. In the MORE TABLES form, the number of records for the selected table is indicated. The position of the current record is also indicated. This position is based on the alphabetic order; it has no effect on the data.

Page 17: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

Geotab - Field application 11

Entry forms 2019-08-21

5.2. Options in the title bar of the entry forms

Some options are available in the title bar depending on the current entry form. 5.2.1. Gmap (Beta version)

In the Boring form, the Gmap option is present in the title bar. It is active when the longitude and latitude of the boring are entered. The option opens a Google Map plan view showing the boring location. Internet access is necessary. See paragraph 7.1. 5.2.2. GPS location

In the Boring form, the GPS location option is present in the title bar, to retrieve the longitude and latitude of the tablet. See paragraph 7.1. 5.2.3. QR Code (Beta version)

In the Sample form, the option to create a QR code is present in the title bar. It is used to create a QR Code for the current sample.

5.2.4. Add layer

In the Sample form, the option to Add a stratigraphic layer is present in the title bar. It is used to automatically create layers from the samples. See paragraph 11. 5.2.5. Observations

In all the forms except Site, the observations option is present. This option opens a dialog box above the current form. The dialog box is used to describe any observation or remark from the field, at a given depth. To return to the current form, the Home and Cancel options are available as in the other entry forms. See paragraph 15.

5.3. Options menu of the entry forms

The options menu of the entry forms shown in Figure 9 opens with this button. Some of the options are not present depending on the entry form.

5.3.1. Complete form

The Complete form option opens the More tables form on the current table, to see all its fields as a two-column table. See paragraph 16 for the description of the More tables form. 5.3.2. Delete record

The delete record option is used to delete the current record. If the record contains dependant data, the deletion is not possible. Note: if a form also contains a table, the data in the table are also deleted since they belong to the main record. A message indicating the table involved asks to confirm the deletion. By clicking No, nothing is done. By clicking Yes, the record is deleted and the form is closed to return to the boring log.

Page 18: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

12 Geotab - Field application

2019-08-21 Entry forms

5.3.3. Cancel

The cancel option is used to cancel any change and return to the log. A message asks to confirm the cancelation. By clicking No, nothing is done. By clicking Yes, the modifications are cancelled and the form is closed to return to the boring log.

Figure 9 – Options menu of the entry forms 5.3.4. Select fields

The select fields option is used to customize the current form. The option opens a three-column window, namely Field, Active and Label (see Figure 10).

• Field: All fields of the current table in the connected database are listed in this column.

• Active:

The fields displayed by default in the current form have a checked box that cannot be modified.

All other fields can be activated in order to be available in the current form, following the default fields.

• Label:

The label of the default fields cannot be modified.

The suggested label for the other fields is the same as the field name, but can be modified.

By clicking OK, the changes are saved in the current database and are reflected in the entry form from which the option was called. Any new project created from the customized database will have the same formatting for its entry forms. See paragraph 4.6.6 for the creation of a project.

Page 19: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

Geotab - Field application 13

Entry forms 2019-08-21

Figure 10 – Selection of fields

5.3.5. Units of depths

The entry forms that have depth fields have the options of depths in meters or depths in feet. The units “m” or “ft” are indicated next to the depth fields based on the selected option. The user enters the values in the selected unit and the values are saved in the database in the unit system designated in the Site entry form (see paragraph 6), either SI (international system) or IM (imperial system). 5.3.6. Units of lengths

The Sample and Piezometer entry forms have the options of lengths in meters and lengths in feet. The Sample form also has the options of lengths in inches and lengths in centimeters. The units “m”, “ft”, “in” or “cm” are indicated next to the length fields based on the selected option. The user enters the values in the selected unit and the values are saved in the database in the unit system designated in the Site entry form (see paragraph 6), either SI (international system) or IM (imperial system).

5.4. Button bar of the entry forms

5.4.1. Previous

The previous button is active in the SAMPLE and PIEZOMETER forms, when at least 2 records exist for the current boring. It is also active in the MORE TABLES form, when at least 2 records exist in the selected table. It is used to go to the previous record. When the previous button is touched, any modification is automatically saved.

Page 20: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

14 Geotab - Field application

2019-08-21 Entry forms

5.4.2. Save

The save button becomes active as soon as a change is done in the current form. When the changes are saved, the disk becomes inactive again until the next change. 5.4.3. Insert

The insert button is active in the BORING, SAMPLE, PIEZOMETER and MORE TABLES forms. It is used to insert a new empty record following the current one. When the insert button is touched, any modification is automatically saved. See the description of these entry forms for details about the automatisms when inserting a new record. 5.4.4. Drawing

The drawing button is active in all forms except Site, and opens a drawings window integrated to Geotab. The drawings window is shown in Figure 11 (the white page takes up the entire screen of the tablet). On opening, the page is blank.

Figure 11 – Creation of drawings The first button is used to create a new blank page. A confirmation message indicates that all changes will be lost. The second button is used to choose the size of the brush, between 4 choices. All following strokes will have this diameter. The third button is used to choose the size of the eraser, between 4 choices. The eraser is displayed in black following the movement of the stylus or finger during editing, to indicate what will be erased. When the stylus or finger is lifted from the tablet, the image is refreshed. The fourth button is used to save the drawing. The drawing is saved in the project folder, at the same location as the database.

• A message asks to confirm the save. If yes, the drawings window closes and returns to the current form. If cancel, the drawing remains open without being saved.

• If the drawing option was called from the Sample form, the drawing is named SITE_BORING_SAMPLE_date-time.png

• If the drawing option was called from any other form, the drawing is named SITE_BORING_date-time.png

The buttons at the bottom of the drawings window are used to choose the color of the strokes. The back button of the tablet closes the drawings window without saving.

Page 21: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

Geotab - Field application 15

Entry forms 2019-08-21

5.4.5. Photo

The photo button is active in all forms except Site, and opens the Camera application of the tablet. The photo is saved in the project folder, at the same location as the database.

• If the photo option was called from the Sample form, the photo is named SITE_BORING_SAMPLE_date-time.jpg

• If the photo option was called from any other form, the photo is named SITE_BORING_date-time.jpg

5.4.6. Next

The next button is active in the SAMPLE and PIEZOMETER forms, when at least 2 records exist for the current boring. It is also active in the MORE TABLES form, when at least 2 records exist in the selected table. It is used to go to the next record. When the next button is touched, any modification is automatically saved.

5.5. Generalities of the forms

5.5.1. Swiping

When a form is opened, it is possible to go to the next one by swiping the form to the left or to the right, with the stylus or 1 finger. The virtual order of the forms, from left to right, is Site - Boring - Sample - Stratigraphy - Vane Test - Pen Test - Piezometer. Any modification is automatically saved when swiping. 5.5.2. Required values

In all the forms, at least one field is required. These values are indicated by an asterisk. If no value is present in a required field, the record cannot be saved. The required values make each record unique. If a value in a required field would create a duplicate, it is not possible to save either. 5.5.3. Lists in date fields

For all date fields, this button opens the date editor of Android. By clicking OK, the date and time are inserted, without the seconds. 5.5.4. Lists of values

The fields with this button have a list of values or a list that can be created. First, the list gets the records available in the LIST_ENG or LIST_FRE table, whether Geotab is used in English or French (see paragraph 4.6.10.1). If there are records for the corresponding table and field, they will be displayed in the list of values. The scrolling list shows the values, on the left, and their description, on the right. It is the value that is inserted in the field. Secondly, if no records are found in the tables of lists, the list is populated with the values entered for the same field in other records of the database.

Page 22: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

16 Geotab - Field application

2019-08-21 Entry forms

Figure 12 – Adding values in the lists The + NEW option is always present at the top of the list. This option is used to add values for the current field in the LIST_ENG or LIST_FRE table, depending on the language of Geotab. The dialog box shown in Figure 12 is displayed. You must enter a value and description. By touching OK, the value and description are added to the list of values and the value is entered in the field. ** If the point (.) is used as value, it is the description that is entered in the field. **. 5.5.5. Tables

The forms either show single records, multiple records in table format, or a combination of both. Tables are used to show secondary data belonging to a main record. The headers indicate the field names, with the required fields having an asterisk. 5.5.5.1. Horizontal scrolling

The expand button is available at the top left of the tables. It is used to activate the horizontal scrolling to see all fields and widen the remark. The scrolling is then possible by placing the finger or stylus inside the table and moving right or left. When the horizontal scrolling is active, the shrink button becomes available instead of the previous button. It is used to return to the default display without horizontal scrolling. 5.5.5.2. Insert

An insert button is available right of the last existing row. It adds a new row after the others. At any time, a new empty row is automatically displayed after the existing rows when opening the form. 5.5.5.3. Delete

When a checkbox left of a row is selected, the Deletion button appears in the title bar just left of the Observations button. Selecting the button opens a confirmation message indicating the table involved. By clicking No, nothing is done and the selection is canceled. By clicking Yes, the record is deleted and the form remains open. Multiple rows can be selected and deleted at once. 5.5.6. Default values

When inserting new records, some default values are automatically entered. The following paragraphs present them more specifically.

Page 23: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

Geotab - Field application 17

SITE form 2019-08-21

Note that the current date is generally displayed by default when inserting records. Also, depths are often incremented automatically when inserting new rows.

6. SITE FORM

The SITE form is used to identify and describe a site. It is opened via the list of forms in the boring log toolbar or by touching the log header.

• The site number is required. It contains 20 characters maximum.

The site number can only contain letters, numbers and the following characters: the dash, the parentheses, the dot and the underscore. Accents are not allowed.

When inserting a new site, the site number must be entered in the dialog box. A number is necessary to insert other data.

When consulting an existing site, it is possible to modify the site number by activating its field. A dialog box opens to enter the new number. All dependent records will be modified.

• A structure number can be entered, with 20 characters maximum.

• The unit system is selected from SI (international system) and IM (imperial system). This indicates if the depth and length values entered in the database are considered to be in SI or IM units. By default, SI is selected. The unit conversions in the entry forms are applicable, either way (see paragraphs 5.3.5 and 5.3.6).

Figure 13 – SITE form

• The user chooses the MTM or UTM coordinate system for his site by clicking on the corresponding button. The information is used for the borings coordinates. By default, MTM is selected.

• The user chooses the NAD27 or NAD83 projection system for his site by clicking on the corresponding button. The information is used for the borings coordinates. By default, NAD83 is selected.

• The zone where the site is located is entered. Automatically, the site’s zone will be copied as the zone of its borings, but it is modifiable.

Page 24: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

18 Geotab - Field application

2019-08-21 BORING form

• The location of the site can be described in details, with 255 characters.

• The description is used to add information about the site, with 255 characters.

7. BORING FORM

The BORING form is used to identify and describe the borings of a site. It is opened via the list of forms in the boring log toolbar or by touching the depth column in the log.

7.1. Generalities

The Generalities button is selected by default.

• The boring number is required. It contains 20 characters maximum.

The boring number can only contain letters, numbers and the following characters: the dash, the parentheses, the dot and the underscore. Accents are not allowed.

When inserting a new boring, the boring number must be entered in the dialog box. A number is necessary to insert other data.

When consulting an existing boring, it is possible to modify the boring number by activating its field. A dialog box opens to enter the new number. All dependent records will be modified.

• The boring type is a 2-character code that indicates the nature of the boring. The default codes present in the Geotec database are listed below. When boring types HA, TP or TR are selected, the third button in the Boring entry form is labelled “TRENCH”; see paragraph 7.5. Otherwise, the third button is labelled “CASINGS”; see paragraph 7.4.

Table 1 - Types of borings in Geotec

Code Description Code Description

AS Auger sampler hole PZ Stand alone piezometer

AT Air track QC Quality control

BH Borehole SP Static penetrometer

CO Cobra SS Swedish sampler

CP Piezocone ST Special test

GP Guelph permeameter TP Test pit

HA Hand auger TR Trench

MA Manual sampling VN Vane test

NA Non applicable (dummy) WS Water station

PT Dynamic penetration test

• The start date of the boring is indicated with the “yyyy-mm-dd hh:miˮ format. The current date and time are entered by default when creating a new boring.

• The end date of the boring is indicated with the “yyyy-mm-dd hh:miˮ format.

• The location of the boring can be described in details, with 80 characters.

• The MTM or UTM coordinate system and the NAD27 or NAD83 projection system selected for the site are displayed, but not modifiable. The information is used for the borings coordinates.

Page 25: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

Geotab - Field application 19

BORING form 2019-08-21

• The zone where the boring is located is entered. The zone of the site is displayed by default but can be modified.

Figure 14 – BORING form - Information

• The longitude and latitude of the boring are entered or calculated; in degrees.

By touching the GPS location button, the longitude and latitude of the tablet are retrieved. The easting (X), northing (Y) and zone are calculated at the same time, if the coordinate and projection systems are defined and if the calculation option in the parameters is checked. See the parameters at paragraph 4.6.10.6.

The GPS location of the tablet must be activated.

The option Enable GPS in the options menu of the Boring form must be checked. When checked, the location is retrieved continuously.

Page 26: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

20 Geotab - Field application

2019-08-21 BORING form

If the longitude and latitude of the boring are available, the Gmap button of the title bar becomes active. The option opens a Google Map plan view to show the boring location. Internet access is necessary.

• The X and Y coordinates of the boring are entered or calculated

The buttons << and >> are used to calculate the longitude and latitude based on X, Y and the zone; or the X, Y and zone based on the longitude and latitude, respectively. The coordinate and NAD systems are necessary for the calculations.

• The reference is a string of 40 characters used to indicate the reference type for the boring (for example: geodesic, arbitrary).

• Z is the ground elevation at the boring’s location.

• The total depth of the boring is incremented automatically as data are entered in the Sample, Stratigraphy, Vane Test or Pen Test forms. It can be modified manually.

• The equipment used is entered, with 40 characters.

• The type of hammer used for driving the sampler is entered, with 40 characters.

• The contractor who completed the boring is entered, with 80 characters.

• The driller, the technician and the project manager can be entered; with 40 characters.

• A remark containing up to 255 characters is used to add information about the boring.

7.2. Water table

The Water table button modifies the form to insert values of water measurements. Information about 2 water measurements can be entered.

• The measurement date, with the “yyyy-mm-dd hh:miˮ format

• The casing depth at the time of measurement

• The stabilization time, in hours

• The water depth

7.3. Insert new boring

The Insert button is active in the button bar of the entry form when the Generalities or Water table button is selected. It is used to create a new boring by copying some of the information of the current boring: the type, zone, reference (z), and values in equipment to remark. After entering the new boring number, the entry form closes to return to the report of the new boring.

7.4. Casings

When the boring type is neither HA, TP nor TR, the 3rd button in the Boring entry form is labelled “CASINGS”. The form is used to input the different casings and their driving mode.

• The top and bottom depths are required. They indicate the depths between which the casing was installed.

• The caliber of the casing used is entered.

• The driving mode contains a 1-character code.

• The description of the selected mode is automatically displayed in the Remark field but can be modified.

Page 27: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

Geotab - Field application 21

BORING form 2019-08-21

Figure 15 – CASINGS form

7.5. Trench

When the boring type is HA (hand auger), TP (test pit) or TR (trench), the 3rd button in the Boring entry form is labelled “TRENCH”.

Figure 16 – TRENCH form

• The length and width of the trench are entered.

• The type of refusal during the excavation is indicated with a 1-character code; for example: “R” for refusal on rock, “B” for refusal on boulder, etc.

Page 28: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

22 Geotab - Field application

2019-08-21 SAMPLE form

• The method or excavation equipment is entered with 40 characters.

• The excavation difficulty is entered; with 255 characters.

• The wall stability can be described with 255 characters.

• The depth of the water inflow is entered.

• A description of the water conditions is entered; with 255 characters.

• The top and bottom depths of an oxidized zone can be entered.

• A description of the oxidation conditions is entered with 255 characters.

• A remark can be added.

8. SAMPLE FORM

The SAMPLE form is used to describe the samples taken along a boring. By default, the Remoulded button is selected. When another state is selected, it becomes the default state. The following information is general. See paragraphs 8.1 to 8.3 for information specific to the three states.

• A depth increment can be entered.

A new sample will be positioned at a depth equal to the sum of the top depth of the preceding sample and the increment.

o If this value is smaller than the bottom depth of the preceding sample, it is the bottom depth of the preceding sample that will be used.

Without an increment, we consider continuous sampling. A new sample will be positioned at a depth equal to the bottom depth of the preceding sample.

• The sample number is required. It contains 19 characters maximum. It corresponds to the field GENERIC_NO of the database.

The sample number can only contain letters, numbers and the following characters: the dash, the parentheses, the dot and the underscore. Accents are not allowed.

This number is automatically copied in the field SAMPLE_NO of the database.

• The sampling date is entered with the “yyyy-mm-dd hh:mi” format. The current date and time are entered by default when creating a new sample.

• The sample type is a 3-character code to indicate the type of sampler used to extract the sample. The type of the previous sample is entered by default. The default codes present in the Geotec database are:

Table 2 - Types of samplers in Geotec

Code Sampler Code Sampler

AS Auger sampler SS Split spoon

BS Bulk sample ST Thin wall sampler (Shelby)

CT Corer tube TW Thin wall sampler

DC Diamond rock core VI Vibration

MA Manual WC Water content

PS Piston sampler WS Wash sample

QC Quality control sample X2 Bentonite run

Page 29: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

Geotab - Field application 23

SAMPLE form 2019-08-21

SC Split corer

• The sample depths (from top to bottom) are entered. If both depths are entered, the sample length is calculated.

• The sample length is either calculated by entering the bottom depth, or entered directly. The bottom depth is then calculated.

A length of 0.61m (or 2 feet) is proposed by default; then, the length of the previous sample is entered by default.

• For the recovery, you can enter the recovery length; the total length of the sample is also displayed as an indication. The recovery % is then calculated.

• The recovery % is either calculated by entering the recovery length, or directly entered. The recovery length is then calculated.

• The sample description can be inserted directly, with 255 characters. The selection matrix can be opened by clicking on the button. See paragraph 10 for all the details.

Figure 17 – SAMPLE form

8.1. Remoulded

• The casing caliber is noted; with 10 characters.

Page 30: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

24 Geotab - Field application

2019-08-21 STRATIGRAPHY form

The caliber of the previous sample is entered by default.

• The number of blows per 6” (N1 to N4) are entered; integers.

• The sum of N2 and N3 is entered in the field N which contains the standard penetration value. The value of N can be modified.

• A remark on N can be entered.

8.2. Undisturbed

• The tube number of the undisturbed sample is entered, with 10 characters.

8.3. Rock core

• The core caliber is noted; with 10 characters.

The caliber of the previous sample is entered by default.

• For the RQD, you can enter the cumulative length of core pieces greater than 4 inches; the total length of the sample is also displayed as an indication. The RQD (%) is then calculated.

• The RQD (%) is either calculated by entering the length, or directly entered. The length is then calculated.

8.4. Sub-samples

In the bottom table of the form, you can add sub-samples to the main sample indicated at the top.

• The sub-sample number is required; for example, A, B, …. It has 1 character.

This number is automatically concatenated to the main number of the sample and copied in the field SAMPLE_NO of the database (ex: 2A, 2B)

The number of the 1st sub-sample is set to ‘A’ by default. The number of the following sub-samples is incremented alphabetically. These values can be modified.

• The sub-sample depths (from top to bottom) are entered. If both depths are entered, the sub-sample length is calculated.

By default, the top of the 1st sub-sample is the top of the main sample. The top of the following sub-samples is equal to the bottom of their preceding sub-sample. These values can be modified.

By default, the bottom of the last sub-sample is equal to the bottom of the main sample and the length is calculated. The bottom depth can be modified.

• The sub-sample length is either calculated by entering the bottom depth, or entered directly. The bottom depth of the sub-sample is then calculated.

• The sub-sample description can be inserted directly, with 255 characters. The selection matrix can be opened by clicking on the button. See paragraph 10 for all the details.

9. STRATIGRAPHY FORM

The STRATIGRAPHY form is used to describe the stratigraphy along a boring.

• The classification type is required.

Page 31: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

Geotab - Field application 25

STRATIGRAPHY form 2019-08-21

By default, the type of the 1st layer is ‘S’. For the following layers, the type is equal to the type of the previous layer.

The default codes are:

o End of boring: to add a description explaining the conditions of the end of the boring, which will be displayed at the bottom of the boring log produced by the Log module

o Rock: the top depth of the 1st rock layer is copied in the ROCK_DEPTH field of the boring

o Simplified

o Text: to display a remark at any depth, without having to define a dummy layer.

o Unified

Figure 18 – STRATIGRAPHY form

• The top depth of the layer is required. By default, the top of the 1st layer is 0 meter (or feet). The top of the following layers is equal to the bottom of their preceding layer. These values can be modified.

• The bottom depth of the layer is entered, if applicable. A bottom depth is necessary to display the layers of type S, U and R.

• The layer description can be inserted directly, with 255 characters. The selection matrix can be opened by clicking on the button. See paragraph 10 for all the details.

Page 32: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

26 Geotab - Field application

2019-08-21 Selection matrix

10. SELECTION MATRIX

The selection matrix (Figure 19) is opened via the button located right of the Description field for the samples, sub-samples or stratigraphy. The matrix is used to describe the soil and create its description automatically.

10.1. Duplicate previous

The button Duplicate previous sample or Duplicate previous layer is used to copy the information from the matrix of the record that immediately precedes in depth. The description is also copied, even if it was manually modified. You can then make adjustments and click OK to insert the information in the current record.

10.2. Selection of materials

10.2.1. Fill

When the Fill checkbox is selected, the word ‘Fill:’ is written at the beginning of the description. 10.2.2. Scrolling list of materials

The scrolling list at the top right of the window presents simplified classification materials that can be selected individually. Only one can apply per sample or layer. When a material is selected, the matrix is reset. 10.2.3. Simplified classification

The table can be used to select the simplified classification of the soil. The first material selected is automatically set to ‘Main’. Also, only two materials can be selected as ‘Main’; the third being automatically set to ‘Adjective’ for a maximum of 100% material. The remove a material selection, touch the radio button again. If a material was selected in the scrolling list, the matrix is reset. 10.2.4. Presence

You can check if there was a presence of cobbles, blocks, organic matter and / or debris. 10.2.5. Code and proportion

The codes corresponding to the materials in the scrolling list, the table and the presences are indicated at the top of the matrix. Up to 6 materials can be selected. The proportions are also indicated, with the first number corresponding to the first code, etc. The patterns associated to the codes and proportions are displayed in the log.

• A main material (from the table or the scrolling list) has a proportion of 1 (> 35%)

• An adjective has a proportion of 2 (20-35%)

• ‘Some’ has a proportion of 3 (10-20%)

• ‘Traces’ or ‘Presence’ has a proportion of 4 (< 10%)

10.3. Color

The color can be entered. It is concatenated to the description. A list of colors is also available in the scrolling list. See paragraph 5.5.4 for details about how the list is managed.

Page 33: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

Geotab - Field application 27

Selection matrix 2019-08-21

Figure 19 – Selection matrix

10.4. Compaction or consistency

Up to two radio buttons can be selected under compaction or under consistency. The range of compaction or consistency is concatenated to the description. If the N-value is entered in the sample definition, the corresponding degree of compaction is automatically selected based on the following table. The N-value is also indicated as information.

N-value Compaction

Less than 4 Very loose

4-10 Loose

10-30 Compact

30-50 Dense

50 and more Very dense

Page 34: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

28 Geotab - Field application

2019-08-21 Automatic creation of layers

10.5. Moisture

Up to two radio buttons can be selected under moisture. The range of moisture is concatenated to the description.

10.6. Description

The soil description is generated based on the selections in the matrix. It can be manually modified. If modified, the description will be displayed in red in the selection matrix, indicating that it is different than the automatically generated description. The user can regenerate the description with this button.

10.7. Exit

Use Cancel to exit the matrix without keeping the changes. Use OK to exit the matrix and enter the generated description in the field Description. It will replace a description that was already entered.

11. AUTOMATIC CREATION OF LAYERS

In the Sample form, the button to Add a stratigraphic layer is present in the title bar. It is used to automatically create layers from the samples. When the button is clicked, the selection matrix is displayed, for the new layer. The top depth is the greatest depth found in the Stratigraphy table, or 0 if no stratigraphy has been created.

• If the current sample or the checked sub-sample contains no description when the add button is clicked, the bottom depth of the proposed layer is the top depth of the current sample / sub-sample.

• If the current sample or the checked sub-sample contains a description when the add button is clicked, the bottom depth of the proposed layer is the bottom depth of the current sample / sub-sample.

The selections in the matrix take into account all samples between the top and bottom depths of the proposed layer.

• If Fill was selected in any of the samples of the new layer, it is selected.

• If a material from the scrolling list was selected in any of the samples of the new layer, it is selected.

• If only materials from the table were selected in the samples of the new layer, a weighted average based on lengths is calculated.

• If a presence was selected in any of the samples of the new layer, it is selected.

• All colors of the samples of the new layer are concatenated.

• The widest range of degrees of compaction or consistency found in the samples of the new layer is selected.

If compaction and consistency are selected in samples of the new layer, compaction is used.

• The widest range of moisture found in the samples of the new layer is selected.

Page 35: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

Geotab - Field application 29

VANE TEST form 2019-08-21

The values can be modified for the new layer. By clicking OK, the layer is saved. If the top depth of the layer to be created is greater or equal to the bottom depth, the title of the matrix is in red and it is not possible to create the layer.

12. VANE TEST FORM

The VANE TEST form is used to define a vane test and the resistance measurements.

• The test date is entered with the “yyyy-mm-dd hh:mi” format. The current date and time are entered by default when inserting a vane test for the current boring.

• The apparatus number is entered, with up to 20 characters.

• The type of blade indicates its dimensions, for example; with 40 characters.

Figure 20 – VANE TEST form

• The most recent calibration date is entered with the “yyyy-mm-dd hh:mi” format.

• The K calibration coefficient of the apparatus is entered, with 3 decimals.

• Remark contains a string of 255 characters for additional information.

Page 36: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

30 Geotab - Field application

2019-08-21 PEN TEST form

In the bottom table of the form, we add the shear strengths for the vane test.

• Depth is required; we enter the depth of the vane resistance measurement.

• The maximum shear strength SU (unremolded soil) is entered. The suggested unit is the kPa.

• The residual shear strength SUR (remolded soil) is entered. The suggested unit is the kPa.

• Remark contains a string of 255 characters to add information.

13. PEN TEST FORM

The PEN TEST form is used to define dynamic penetration tests.

• The depth increment per measurement can be inputted. A value of 0.3048m (1 ft) is displayed by default. The increment is used when inserting new rows in the bottom table.

• The hammer weight is generally entered in kg.

• The height of fall is generally entered, in meters.

Figure 21 – PEN TEST form In the bottom table, we add the test measurements.

• Depth is required; enter the top depth of the measurement, before the blows.

By default, the 1st depth is 0m. The following depths are increased by the depth increment or by 0.3048m (1 ft) if no increment is entered.

Page 37: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

Geotab - Field application 31

PIEZOMETER form 2019-08-21

• The number of blows necessary for the cone to penetrate from the current depth to the following.

• Remark contains a string of 255 characters to enter additional information.

14. PIEZOMETER FORM

The PIEZOMETER form is used to define the characteristics of piezometers, as well as various layers of materials used during their installation and the piezometric levels recorded. The form is separated in two sections. The top is used to describe the piezometers. The bottom is used to enter information about the seals and the piezometric levels. See paragraphs 14.4 and 14.5 for details about the bottom.

Figure 22 – PIEZOMETER form - Open tube and Seals By default, Open tube is selected. When another piezometer type is selected, it becomes the default type. The following information is general. See paragraphs 14.1 to 14.3 for information specific to the three types.

Page 38: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

32 Geotab - Field application

2019-08-21 PIEZOMETER form

• The piezometer number is required. It contains 20 characters maximum.

The piezometer number can only contain letters, numbers and the following characters: the dash, the parentheses, the dot and the underscore. Accents are not allowed.

• The installation date is entered with the “yyyy-mm-dd hh:mi” format. The current date and time are entered by default when creating a new piezometer.

• For the filter description

The installation depth is the bottom depth of the filter.

The length of the filter is entered.

The filter diameter is entered, in millimeters.

• A remark is used to describe the piezometer, with up to 255 characters.

14.1. Open tube

• The length above ground is entered. It corresponds to the distance between the top of the tube and the natural ground. If a tube is installed below ground, the length will be negative.

• The tube diameter is entered, in millimeters.

14.2. Pneumatic

• You enter the inertia correction factor.

14.3. Electric

• The linear equation or polynomial equation can be selected with the radio buttons. The linear equation is selected by default.

• The installation reading R0 is entered (in linear units LU).

• The temperature at installation T0 is entered (in Celsius degrees).

• The barometric pressure at installation B0 is entered (in kPa).

• The thermic coefficient TC is entered (in kPa / Celsius degree).

• The calibration factor CF is entered (in kPa / LU). This coefficient is used with the linear equation.

• The A coefficient is entered (in kPa / LU2). The value in scientific format can be entered. This coefficient is used with the polynomial equation.

• The B coefficient is entered (in kPa / LU). This coefficient is used with the polynomial equation.

• The C coefficient (in kPa) is calculated automatically via: 0

2

0

610 BRRAC −−= −

Page 39: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

Geotab - Field application 33

PIEZOMETER form 2019-08-21

Figure 23 – PIEZOMETER form - Electric and Levels

14.4. Seals

The Seals button is used to enter the installation materials. The information applies to the current boring, not to a specific piezometer.

• The top and bottom depths are required. The materials are listed in the table from deepest to shallowest.

By default, the bottom of the first material is equal to the total depth of the boring (see paragraph 7.1). The bottom of the following materials is equal to the top of the previous. These values can be modified.

• The code of the seal has 3 characters maximum and indicates the material, based on the simplified classification. On the log, the seal is drawn with the pattern defined for this code.

• A description of the material can be added.

14.5. Levels

The Levels button is used to enter the piezometric levels recorded for the current piezometer. The table differs depending on the piezometer type.

• The measurement date is required. It indicates when the measurement was taken, with the “yyyy-mm-dd hh:mi” format. The current date and time are indicated by default when creating a new level.

Page 40: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

34 Geotab - Field application

2019-08-21 OBSERVATION dialog box

• The reading is entered. It can be:

Open tube: the water depth relative to the top of the tube; the suggested unit is the meter.

Pneumatic: the pressure reading, in kPa.

Electric: the reading on the dial, in LU.

• T1 is displayed when Electric is selected. It is the temperature during the reading.

• B1 is displayed when Electric is selected. It is the barometric pressure during the reading.

• The pressure is calculated based on the following equations.

Open tube: 806.9)sin()__( 1 −−= dipRdabovegrounlengthdepthoninstallatiP

Pneumatic: inertiaRP −= 1

Electric:

Linear equation: )()()( 010101 BBTTTCRRCFP −−−−−=

Polynomial equation: )()(10 01011

2

1

6 BBTTTCCBRRAP −−−−++= −

• The piezometric level (in meters) is calculated based on the following equation :

806.9)sin(_ PdipdepthoninstallatiTNLevel +−=

where TN is the natural ground elevation (Z) defined in the Boring form

• The remark is a 2-character code to add an indication about the measurement.

15. OBSERVATION DIALOG BOX

The OBSERVATION dialog box is used to describe any observation done on the field, at a given depth. The dialog box is opened with the Observation button, from all forms except Site. It is displayed above the form or log from where it was called.

Figure 24 – OBSERVATION dialog box

• The top depth is required.

• The bottom depth can be entered, if it is an observation done for a layer.

• A remark or observation is added with 255 characters.

16. MORE TABLES FORM

The MORE TABLES form is used to see the data from any table or view of the database. It is used to see tables that do not have a specific form.

Page 41: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

Geotab - Field application 35

MORE TABLES form 2019-08-21

When the option Complete form is selected from the options menu of any form (see paragraph 5.3.1), the more tables form is displayed on the corresponding table to see all the table fields. In the options menu, the user can select to have the list of all tables, of all views, or everything from the connected .db3 database. The scrolling list at the top of the form will show the list of tables and/or views, accordingly. By selecting a table / view, the information from the current site and / or boring is displayed below. If the table does not apply to a specific site and / or boring, all records are retrieved.

• If a record is displayed, its data can be modified or completed. However, the key fields of the record cannot be edited and a shown in gray.

• If a new record is added, all fields can be modified, including the keys. The numbers of the current site and boring are proposed by default.

Figure 25 – MORE TABLES form

16.1. Query form

The query button in the More Tables form is used to do a specific query. It opens the window shown in Figure 26, to do a query in the table or view selected in the scrolling list; LIST_ENG in this example.

Page 42: Geotab - Field Application · 2019-10-25 · Geotab - Field application 1 Installation 2019-08-21 l:\english\geotec\geotab\809\geotab_eng.doc GEOTAB - FIELD APPLICATION Geotab is

36 Geotab - Field application

2019-08-21 MORE TABLES form

Any condition can be specified in one or more fields of the form.

• To exit the query form without executing a query, select the first button in the title bar. It returns to the More Tables form.

• To retrieve the last query done in the current table or view, select the second button in the title bar. The query conditions will be filled.

• To execute the query, select the last button in the title bar. The query form will be closed to return to the More Tables form with the result of the query.

Figure 26 – Query conditions