12
Automatic lifting station GEOTRIT, GEOCOMP, GEOCLEAN

GEOTRIT, GEOCOMP, GEOCLEAN - Dukon · 2019-06-20 · 5 GEOTRIT A˚˛ˇ a˛ a˝˛ a˛ ˙ ˛ ˘ ˝˛a˛ ˇ˘ I˘˝˛a a˛ ˇ˘ 4.93.486 D ˘˝ ˇ˘˝ a˘ ˛˝ 3 4 3 1 7 427 271,5 55,5

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: GEOTRIT, GEOCOMP, GEOCLEAN - Dukon · 2019-06-20 · 5 GEOTRIT A˚˛ˇ a˛ a˝˛ a˛ ˙ ˛ ˘ ˝˛a˛ ˇ˘ I˘˝˛a a˛ ˇ˘ 4.93.486 D ˘˝ ˇ˘˝ a˘ ˛˝ 3 4 3 1 7 427 271,5 55,5

Automatic lifting station

GEOTRIT, GEOCOMP, GEOCLEAN

Page 2: GEOTRIT, GEOCOMP, GEOCLEAN - Dukon · 2019-06-20 · 5 GEOTRIT A˚˛ˇ a˛ a˝˛ a˛ ˙ ˛ ˘ ˝˛a˛ ˇ˘ I˘˝˛a a˛ ˇ˘ 4.93.486 D ˘˝ ˇ˘˝ a˘ ˛˝ 3 4 3 1 7 427 271,5 55,5

2

Page 3: GEOTRIT, GEOCOMP, GEOCLEAN - Dukon · 2019-06-20 · 5 GEOTRIT A˚˛ˇ a˛ a˝˛ a˛ ˙ ˛ ˘ ˝˛a˛ ˇ˘ I˘˝˛a a˛ ˇ˘ 4.93.486 D ˘˝ ˇ˘˝ a˘ ˛˝ 3 4 3 1 7 427 271,5 55,5

3

Automatic clear water lifting station . . . . . . . . . . . . . .. . . . . . pag. 8

GEOCLEANGEOCLEAN

Automatic waste water lifting station . . . . . . . . . . . . . .. . . . . pag. 6

GEOCOMPGEOCOMP

Automatic waste water lifting station . . . . . . . . . . . . . .. . . . . pag. 4

GEOTRITGEOTRIT

Page 4: GEOTRIT, GEOCOMP, GEOCLEAN - Dukon · 2019-06-20 · 5 GEOTRIT A˚˛ˇ a˛ a˝˛ a˛ ˙ ˛ ˘ ˝˛a˛ ˇ˘ I˘˝˛a a˛ ˇ˘ 4.93.486 D ˘˝ ˇ˘˝ a˘ ˛˝ 3 4 3 1 7 427 271,5 55,5

4

Characteristic curve

Automatic waste water lifting stationGEOTRITGEOTRITConstructionThis macerating pumping system has been designed to pump

away the waste water from a WC and a washbasin.

It is possibile to use it to add a new cloakroom, washroom or

toilet, in a basement or loft conversion or anywhere

conventional large bore pipework is impractical.

The GEOTRIT macerating system is installed in a case

specifically designed for horizontal outlet spigots.

Installed and used correctly, this unit will give consistent and

reliable service.

The system has a grinder pump, clapet valve and carbon filter.

GEOTRIT is provided with flexible sleeves, elbow, metal hose

clips.

Operating conditionsVoltage: 220-240 V

Frequency: 50 Hz

Degree of protection: IP44

Maximum power input: 550 W

Nominal current: 2,5 A

Vertical pumping: max. 4 m

20 22 26 28 30 32 34

20 22 24 26 28165

4

3

2

1

04,2 4,8 5,4 6 6,6 7,2 7,8

Q m /hl/min

H m

3

4,97 4,05 3,1 1,21 0,27

1104,270

4,880

5,490

2,16

6100

6,6 7,2120

GEOTRIT

U.S. g.p.m.

Imp. g.p.m.

H

72.1222

m

70 80 90 100 110 120 130m /hl/min

3

Q

16

14

12

8

6

4

2

0

ftH

ApplicationGEOTRIT takes waste from : 

L b

WC Washbasin Bidet

Page 5: GEOTRIT, GEOCOMP, GEOCLEAN - Dukon · 2019-06-20 · 5 GEOTRIT A˚˛ˇ a˛ a˝˛ a˛ ˙ ˛ ˘ ˝˛a˛ ˇ˘ I˘˝˛a a˛ ˇ˘ 4.93.486 D ˘˝ ˇ˘˝ a˘ ˛˝ 3 4 3 1 7 427 271,5 55,5

5

Automatic waste water lifting stationGEOTRITGEOTRITInstallation

4.93.486

Dimensions and weights

344

317

427

271,5 55,5

258

183

318,5

184,7

52

2354.93.483

peso: kg 6,8

max 10 m

max 30 m

max 40 m1 m

2 m

3 m

4 m max 1 %

max 20 m

4.93.481

Performance

weight: kg 6,8

Page 6: GEOTRIT, GEOCOMP, GEOCLEAN - Dukon · 2019-06-20 · 5 GEOTRIT A˚˛ˇ a˛ a˝˛ a˛ ˙ ˛ ˘ ˝˛a˛ ˇ˘ I˘˝˛a a˛ ˇ˘ 4.93.486 D ˘˝ ˇ˘˝ a˘ ˛˝ 3 4 3 1 7 427 271,5 55,5

6

ConstructionThis macerating pumping system has been designed to pump

away the waste water from WC, washbasin, bidet and shower.

It is possible to install a complete bathroom in a basement

conversion or loft extension.

The GEOCOMP macerating system is installed in a case

specifically designed for horizontal outlet spigots.

Installed and used correctly, this unit will give consistent and

reliable service.

The system has a grinder pump, clapet valve and carbon filter.

GEOCOMP is provided with flexible sleeves, elbow, metal hose

clips.

Operating conditionsVoltage: 220-240 V

Frequency: 50 Hz

Degree of protection: IP44

Maximum power input: 550 W

Nominal current: 2,5 A

Vertical pumping: max. 4 m

Characteristic curve

5

4

3

2

1

03,6 4,2 4,8 5,4 6 6,6 7,2

Q m /hl/min

H m

3

5 4,89 3,66 1,24 0

1004,1469

4,270

4,880

2,42

5,490

6 6,6110

20 22 2418 26 28 30

2018 22 24 2616

GEOCOMP

H

72.1221

m

60 70 80 90 100 110 120m /hl/min

3

Q

U.S. g.p.m.

Imp. g.p.m.16

14

12

8

6

4

2

0

ftH

ApplicationGEOCOMP takes waste from : 

Automatic waste water lifting stationGEOCOMPGEOCOMP

WC Washbasin Bidet Tube Shower

Page 7: GEOTRIT, GEOCOMP, GEOCLEAN - Dukon · 2019-06-20 · 5 GEOTRIT A˚˛ˇ a˛ a˝˛ a˛ ˙ ˛ ˘ ˝˛a˛ ˇ˘ I˘˝˛a a˛ ˇ˘ 4.93.486 D ˘˝ ˇ˘˝ a˘ ˛˝ 3 4 3 1 7 427 271,5 55,5

7

Installation

4.93.485

Dimensions and weight

344

317

427,5

271,5 55,5

258

183

318,5

184,7

41,5

52

166

2354.93.482

peso: kg 6,8

max 10 m

max 30 m

max 40 m1 m

2 m

3 m

4 m max 1 %

max 20 m

4.93.481

Performance

Automatic waste water lifting stationGEOCOMPGEOCOMP

weight: kg 6,8

Page 8: GEOTRIT, GEOCOMP, GEOCLEAN - Dukon · 2019-06-20 · 5 GEOTRIT A˚˛ˇ a˛ a˝˛ a˛ ˙ ˛ ˘ ˝˛a˛ ˇ˘ I˘˝˛a a˛ ˇ˘ 4.93.486 D ˘˝ ˇ˘˝ a˘ ˛˝ 3 4 3 1 7 427 271,5 55,5

8

Lifting station for clear waterGEOCLEANGEOCLEANConstructionThe system is design to handle the evacuation water from a

domestic kitchen sink, dishwasher and washing machine – all

working at the same time if required.

GEOCLEAN makes the addition of a domestic kitchen or utility

room easy even when below or distant from a drain.

The system has a clapet valve and it cannot be used with

waste waters.

GEOCLEAN is provided with flexible sleeves, elbow, metal

hose clips, plugs.

Operating conditionsVoltage: 220-240 V

Frequency: 50 Hz

Degree of protection: IP44

Maximum power input: 350 W

Nominal current: 1,7 A

Vertical pumping: max. 5 m

Characteristic curve

5

4

3

2

1

01,8 2,4 3 3,6 4,2 4,8 5,4

20 228 12 14 16 18

10 12 14 16 18

Q m /hl/min

H m

3

4,95 4,62 3,46 1,25 1

802,8848

350

3,660

1,97

4,270

4,8 5,0484

GEOCLEAN

H

72.1220

U.S. g.p.m.

Imp. g.p.m.

m

30 40 50 60 70 80 90m /hl/min

3

Q

16

14

12

8

6

4

2

ftH

ApplicationGEOCLEAN takes waste from : 

Kitchen sinkWashbasin Bidet Tube Shower Dishwasher Washing machine

Page 9: GEOTRIT, GEOCOMP, GEOCLEAN - Dukon · 2019-06-20 · 5 GEOTRIT A˚˛ˇ a˛ a˝˛ a˛ ˙ ˛ ˘ ˝˛a˛ ˇ˘ I˘˝˛a a˛ ˇ˘ 4.93.486 D ˘˝ ˇ˘˝ a˘ ˛˝ 3 4 3 1 7 427 271,5 55,5

9

Lifting station for clear waterGEOCLEANGEOCLEANInstallation

4.93.484

Dimensions and weight

344

317

427,5

271,5 55,5

258 31

8,541

,5

52

1124.93.480peso: kg 6,6

max 10 m

1 m

2 m

3 m

4 m

5 m max max 5 m

max 20 m

max 30 m

max 40 m

1 %

4.93.479

Performance

weight: kg 6,6

Page 10: GEOTRIT, GEOCOMP, GEOCLEAN - Dukon · 2019-06-20 · 5 GEOTRIT A˚˛ˇ a˛ a˝˛ a˛ ˙ ˛ ˘ ˝˛a˛ ˇ˘ I˘˝˛a a˛ ˇ˘ 4.93.486 D ˘˝ ˇ˘˝ a˘ ˛˝ 3 4 3 1 7 427 271,5 55,5

10

GEOCLEANGEOCOMPGEOTRIT

Product comparison chart

Page 11: GEOTRIT, GEOCOMP, GEOCLEAN - Dukon · 2019-06-20 · 5 GEOTRIT A˚˛ˇ a˛ a˝˛ a˛ ˙ ˛ ˘ ˝˛a˛ ˇ˘ I˘˝˛a a˛ ˇ˘ 4.93.486 D ˘˝ ˇ˘˝ a˘ ˛˝ 3 4 3 1 7 427 271,5 55,5

11

Page 12: GEOTRIT, GEOCOMP, GEOCLEAN - Dukon · 2019-06-20 · 5 GEOTRIT A˚˛ˇ a˛ a˝˛ a˛ ˙ ˛ ˘ ˝˛a˛ ˇ˘ I˘˝˛a a˛ ˇ˘ 4.93.486 D ˘˝ ˇ˘˝ a˘ ˛˝ 3 4 3 1 7 427 271,5 55,5

07.11 C307GB-1/1Con riserva di modifiche.

Calpeda s.p.a. Via Roggia di Mezzo, 39 - 36050 Montorso Vicentino - Vicenza - Italia

Tel. +39 - 0444 476 476 Fax +39 - 0444 476 477 E. mail: [email protected] www.calpeda.com