4
GNT400 Front End Series 400 Watt AC/DC Universal Input Power Supply Input Voltage Range Universal input, 80 - 270 VAC (See note). Input Frequency 45 - 65 Hz Input Current 120 VAC, 4.2 A. 230 VAC, 2.1 A. Inrush Current Active circuit, 37 A max. peak. Input Fuse F1,F2, 6.3 A for line and neutral. Power Factor 0.99 typical, 0.96 minimum. Earth Leakage Current 100 µA at 120 Vac, 60 Hz Normal. 400 µA at 264 V, 50 Hz Single fault. Output Power 400 W with fan cooling. See derating chart for other conditions. Peak Output Power 450 W for 1 minute, 10% duty cycle. Output Voltage See chart. Voltage Adjustability +/- 5% minimum. Minimum Load Not required. Total Regulation See chart. • Compact 4” x 7” x 1.5” U Channel (1U Compatible) 9.5 W/in 3 • 100-240 VAC Input with Active PFC • 12 to 48 V DC Output at 400 W • 5 Vdc 100 mA Standby Output • 12 V DC Fan Output • Approved to UL, CSA and EN/IEC Standards • 300 W Convection Rating • Less than 100 μA Leakage • Compliance to EN55011/22 Conducted Noise B • RoHS Compliant-Category 6 2 Year Warranty Transient Response 500 µs to 1%, 0.2 A/µs, 3.5% for 50% step load change. Turn On Time 500 ms max. Hold-up Time 20 ms at 400 W. Over/Undershoot 3.5% max. Overload Protection Cycling type, 470 W typical. Overvoltage Protection See chart. Ripple and Noise 1% pk-pk max., 20 MHz BW. Remote Sense Compensates for up to 500 mV. Commercial Safety Standards UL/EN/CSA 60950-1. Medical Safety Standards UL/EN/IEC60601-1 Thermal Considerations Component Recommended Max. Temperature T5 cover indentation 90°C T1 Inside coil 100°C Switching Frequency Output 170 kHz +/-8 kHz. PFC 140 kHz +/-8 kHz. Specifications All specifications are typical at nominal input, full load at 25°C unless otherwise stated The GNT400 provides 400 W of DC output power in a compact package. Standby, control and monitoring inputs and outputs provide all the essential elements for a variety of applications including, single board computers, running motors, pumps, and solenoids. Approval to EN60601-1 and EN60950 improves design-in time and reduces end system compliance costs. SL Power Electronics Corp. 6050 King Drive Ventura, CA 93003 Phone:805.486.4565 Fax:805.487.8911 Email:[email protected] www.slpower.com

GNT400 - datasheet.octopart.com

  • Upload
    others

  • View
    12

  • Download
    0

Embed Size (px)

Citation preview

Page 1: GNT400 - datasheet.octopart.com

GNT400Front End Series 400 Watt AC/DC

Universal Input Power Supply

InputVoltageRange Universalinput,80-270VAC(Seenote).

InputFrequency 45-65Hz

InputCurrent 120VAC,4.2A.230VAC,2.1A.

InrushCurrent Activecircuit,37Amax.peak.

InputFuse F1,F2,6.3Aforlineandneutral.

PowerFactor 0.99typical,0.96minimum.

EarthLeakageCurrent 100µAat120Vac,60HzNormal.400µAat264V,50HzSinglefault.

OutputPower 400Wwithfancooling.Seederatingchartforotherconditions.

PeakOutputPower 450Wfor1minute,10%dutycycle.

OutputVoltage Seechart.

VoltageAdjustability +/-5%minimum.

MinimumLoad Notrequired.

TotalRegulation Seechart.

• Compact 4” x 7” x 1.5” U Channel (1U Compatible) • 9.5 W/in3 • 100-240 VAC Input with Active PFC • 12 to 48 V DC Output at 400 W • 5 Vdc 100 mA Standby Output • 12 V DC Fan Output • Approved to UL, CSA and EN/IEC Standards • 300 W Convection Rating • Less than 100 μA Leakage • Compliance to EN55011/22 Conducted Noise B • RoHS Compliant-Category 6

2 Year Warranty

TransientResponse 500µsto1%,0.2A/µs,3.5%for50%steploadchange.

TurnOnTime 500msmax.

Hold-upTime 20msat400W.

Over/Undershoot 3.5%max.

OverloadProtection Cyclingtype,470Wtypical.

OvervoltageProtection Seechart.

RippleandNoise 1%pk-pkmax.,20MHzBW.

RemoteSense Compensatesforupto500mV.

CommercialSafetyStandards UL/EN/CSA60950-1.

MedicalSafetyStandards UL/EN/IEC60601-1

ThermalConsiderations Component RecommendedMax.Temperature T5coverindentation 90°C T1Insidecoil 100°C

SwitchingFrequency Output170kHz+/-8kHz.PFC140kHz+/-8kHz.

Specifications All specifications are typical at nominal input, full load at 25°C unless otherwise stated

The GNT400 provides 400 W of DC output power in a compact package. Standby, control and monitoring inputs and outputs provide all the essential elements for a variety of applications including, single board computers, running motors, pumps, and solenoids. Approval to EN60601-1 and EN60950 improves design-in time and reduces end system compliance costs.

SL Power Electronics Corp. • 6050 King Drive • Ventura, CA 93003 • Phone:805.486.4565 • Fax:805.487.8911 • Email:[email protected] • www.slpower.com

Page 2: GNT400 - datasheet.octopart.com

GNT400Front End Series 400 Watt AC/DC

Universal Input Power Supply

Model Volts FanCooled Convection Ripple Total OVP Number Amps Amps &Noise Regulation Threshold

GNT412ABG 12V 33.3A 25A 120mV +/-2% 14V+/-0.75V

GNT424ABG 24V 16.7A 12.5A 240mV +/-2% 26.5V+/-1V

GNT436ABG 36V 11.1A 8.3A 360mV +/-2% 39V+/-1V

GNT448ABG 48V 8.4A 6.3A 480mV +/-2% 55V+/-2V

MTBF 300KhoursperTelcordia.

OvertemperatureProtection Automatic.

Efficiency typical88%@120VAC,91%@240.

Signals PSOn-LowtoInhibit. PSOff-TTLHitoInhibit. PwrOK-HiwhenACisOK100-200msdelay. PwrOK-PFLow4mswarning. DCOK-Hiwhenoutputis>95%.

FanOutput 12Vdc@250mA(turnsoffduringInhibit).

5VStandbyVoltage Alwayson,upto100mA.

EMC/EMIInformation ConductedEmissions EN55011/22 ClassB RadiatedEmissions EN55011/22 ClassA Linefreq.Harmonics EN61000-3-2 ClassA VoltageFluctuations EN61000-3-3 Complies ESD EN61000-4-2 Cont.6kV,Air8kV RadiatedImmunity EN61000-4-3 3V/m FastTransients(EFT) EN61000-4-4 2kV5kHz LineSurgeImmunity EN61000-4-5 2kVCM,1kVDif. ConductedImmunity EN61000-4-6 3Vrms PowerFreq.Mag.Field EN61000-4-8 3A/m VoltageDipImmunity EN61000-4-11 ContactFactory

GeneralSpecifications(continuedfromp.1)

1.Whentheinputvoltageis<90Vac,derateoutputpowerto300Wfancooledor250Wconvection. 2.UsingEorTcoveroptionsallowsfor400Wcontinuousoperationupto40°C. 3.For400W@50°C,use100Ifmfancooling.

Note

OperatingTemperature 0to70°C(seechart).

StorageTemperature -40to+85°C.

OperatingAltitude -500to10,000ft.

Non-operatingAltitude -500to40,000ft.

RelativeHumidity 5%-95%.

Vibration 5Hz-500Hz,2.5grms.

Shock MIL-STD-810E,516.4partIV.

EnvironmentalSpecifications

2 of 4

SL Power Electronics Corp. • 6050 King Drive • Ventura, CA 93003 • Phone:805.486.4565 • Fax:805.487.8911 • Email:[email protected] • www.slpower.com

OutputPowerDeratingCurve

0

50

100

150

200

250

300

350

400

450

0 10 20 30 40 50 60 70

Degrees C

Ou

tpu

t P

ow

er (

Wat

ts)

Fan Cooled

Convection Cooled

Page 3: GNT400 - datasheet.octopart.com

GNT400Front End Series 400 Watt AC/DC

Universal Input Power Supply

3 of 4

SL Power Electronics Corp. • 6050 King Drive • Ventura, CA 93003 • Phone:805.486.4565 • Fax:805.487.8911 • Email:[email protected] • www.slpower.com

MountingOptions

Mating Connectors (Tyco/Amp)Location Option TypeInput A #6-32 Lug .325 CTR

B WireC Amp 640250-5 and 3-770476-1

Output B #10-32 LugT Wire

J3 Amp 64xxxx-8 with socketsJ Fan Amp 64xxxx-2 with sockets

Page 4: GNT400 - datasheet.octopart.com

GNT400Front End Series 400 Watt AC/DC

Universal Input Power Supply

SL Power Electronics Corp. • 6050 King Drive • Ventura, CA 93003 • Phone:805.486.4565 • Fax:805.487.8911 • Email:[email protected] • www.slpower.comDataSheet©2007SLPowerElectronicsCorp.Theinformationandspecificationscontainedinthisdatasheetarebelievedtobecorrectattimeofpublication.However,SLPoweracceptsnoresponsibilityforconsequencesarisingfromreproductionerrorsorinaccuracies.Specificationsaresubjecttochangewithoutnotice.Rev.04/18/07

4 of 4

MountingOptions(continuedfromp.3)