10
20 08/2011 Design 1. Dual wall tube. 2. Stress control tube. 3. Stress control mastic. 4. Non-tracking tube (only for 36GTS1). 5. Overall protection tube. 6. Sealing mastic. 7. Screen continuity (copper mesh). 8. Conductor connector (supplied on request). 9. Ferrule for screen wires. 6/10 (12) kV 6.35/11 (12) kV 8.7/15 (17.5) kV 12/20 (24) kV 12.7/22 (24) kV 18/30 (36) kV 19/33 (36) kV Specifications and standards Meets the requirements of CENELEC HD 629.2 and IEC 60502-4. Up to 36 kV GTS1 HEAT-SHRINKABLE SINGLE CORE XLPE STRAIGHT JOINT Application For jointing polymeric cable to be laid in air or directly buried. The product is fully screened and fully submersible. Straight Joint type Voltage Um (kV) Length “L” (mm) Conductor sizes (mm 2 ) min max 17GTS1 24GTS1 36GTS1 12 & 17.5 24 36 600 - 750 600 - 750 750 - 1000 25 25 35 630 630 800 6 2 9 7 3 4 8 1 5 L

GTS1 - Awali Joints/HEATSHRINK...20 08/2011 Design 1. Dual wall tube. 2. control tube. Stress 3. control mastic. Stress 4. Non-tracking tube (only for 36GTS1). 5.all protection tube

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: GTS1 - Awali Joints/HEATSHRINK...20 08/2011 Design 1. Dual wall tube. 2. control tube. Stress 3. control mastic. Stress 4. Non-tracking tube (only for 36GTS1). 5.all protection tube

20

08/2

011

Design1. Dual wall tube.2. Stress control tube.3. Stress control mastic.4. Non-tracking tube (only for

36GTS1).5. Overall protection tube.6. Sealing mastic.7. Screen continuity (copper

mesh).8. Conductor connector

(supplied on request).9. Ferrule for screen wires.

6/10 (12) kV6.35/11 (12) kV8.7/15 (17.5) kV

12/20 (24) kV12.7/22 (24) kV

18/30 (36) kV19/33 (36) kV

Specifications and standardsMeets the requirements of CENELEC HD 629.2 andIEC 60502-4.

Up to 36 kV

GTS1HEAT-SHRINKABLE

SINGLE CORE XLPESTRAIGHT JOINT

ApplicationFor jointing polymeric cable to be laid in air or directly buried. The product is fully screened and fully submersible.

Straight Jointtype

VoltageUm(kV)

Length“L”

(mm)

Conductor sizes(mm2)

min max17GTS1

24GTS1

36GTS1

12 & 17.5

24

36

600 - 750

600 - 750

750 - 1000

25

25

35

630

630

800

6

2

9

7

3

4

8

1

5

L

Page 2: GTS1 - Awali Joints/HEATSHRINK...20 08/2011 Design 1. Dual wall tube. 2. control tube. Stress 3. control mastic. Stress 4. Non-tracking tube (only for 36GTS1). 5.all protection tube

21

Kit contentsThe complete GTS1 joint kit comprises the following components:

Ordering instructionsSelect the part number corresponding to both system voltage and conductor size.

Example:The copper wire screened cable is 12 kV, 150 mm² stranded aluminium.Order: 17GTS1.240w.

Orderingpart

number

VoltageU0/U(kV)

Conductor size range(mm2)

min max

17GTS1.50w17GTS1.95w

17GTS1.240w17GTS1.630w

17GTS1.1000w

24GTS1.50w24GTS1.240w24GTS1.400w24GTS1.630w

24GTS1.1000w

36GTS1.95i36GTS1.240i36GTS1.500i36GTS1.800i

36GTS1.1200i

6/10 & 6.35/11 & 8.7/156/10 & 6.35/11 & 8.7/156/10 & 6.35/11 & 8.7/156/10 & 6.35/11 & 8.7/156/10 & 6.35/11 & 8.7/15

12/20 & 12.7/2212/20 & 12.7/2212/20 & 12.7/2212/20 & 12.7/2212/20 & 12.7/22

18/30 & 19/3318/30 & 19/3318/30 & 19/3318/30 & 19/3318/30 & 19/33

255095240630

2535150300630

3570185500630

50952406301000

502404006301000

952405008001200

The kit also comprises installation instructions, semi-conductive tape, adhesive tape, a copper braid and a ferrule for the screen wire connection.

+

Sealing mastic

“NGAF”

Black stress control tube

“GT1”

Anti-tracking tube “GT2”

(only for36GTS1)

Stress control mastic

“MNAC”

=+ + XXGTS1straightjoint kit

++

Overallprotection

tube“GT4”

Roll of tinned copper mesh

tape

+

Dualwalltube

“GT25”

For use with copper wire screened cables.No further earthing device is necessary.

For use with coppertape screened cables.

Order: -Aw/-Aiinstead of -w/-i

(e.g. 17GTS1.240Aw).

For use with other cable types.

Please contact our representative.

For use with three-core cables:

see GTS3.

When jointing cables of different sizes,

please contact our representative.

Can be supplied with all common types of

conductor connectors.

Page 3: GTS1 - Awali Joints/HEATSHRINK...20 08/2011 Design 1. Dual wall tube. 2. control tube. Stress 3. control mastic. Stress 4. Non-tracking tube (only for 36GTS1). 5.all protection tube

22

08/2

011

GTS3HEAT-SHRINKABLE THREE CORE XLPE

STRAIGHT JOINT

6/10 (12) kV6.35/11 (12) kV8.7/15 (17.5) kV

12/20 (24) kV12.7/22 (24) kV

18/30 (36) kV19/33 (36) kV

Specifications and standardsMeets the requirements of CENELEC HD 629.2 andIEC 60502-4.

Up to 36 kVApplicationFor jointing three core polymeric cable to be directly buried. The product is fully screened and fully submersible.

Straight Jointtype

VoltageUm(kV)

Length“L”

(mm)

Conductor sizes(mm2)

min max17GTS324GTS336GTS3

12 & 17.52436

1200 - 16001200 - 16001400 - 1800

252535

400400400

Design1. Dual wall tube.2. Stress control tube.3. Screen continuity (copper

mesh).4. Stress control mastic.5. Overall protection tube.6. Sealing mastic.7. Canister. 8. Conductor connector

(supplied on request).9. Non-tracking tube (only for 36GTS3 - not shown).

5

6

6

8

3

1

2

7

4

L

Page 4: GTS1 - Awali Joints/HEATSHRINK...20 08/2011 Design 1. Dual wall tube. 2. control tube. Stress 3. control mastic. Stress 4. Non-tracking tube (only for 36GTS1). 5.all protection tube

23

Ordering instructionsSelect the part number corresponding to both system voltage and cable dimensions.

Example:The cable is 24 kV, 3 x 120 mm2 stranded aluminium with an individual copper tape screen and a steel wire armour.Order: 24GTS3.240k.

Orderingpart

number

VoltageU0/U(kV)

Conductor size range(mm2)

min max

17GTS3.50k

17GTS3.95k

17GTS3.240k

17GTS3.400k

24GTS3.50k

24GTS3.240k

24GTS3.400k

36GTS3.95k

36GTS3.240k

36GTS3.400k

6/10 & 6.35/11 & 8.7/15

6/10 & 6.35/11 & 8.7/15

6/10 & 6.35/11 & 8.7/15

6/10 & 6.35/11 & 8.7/15

12/20 & 12.7/22

12/20 & 12.7/22

12/20 & 12.7/22

18/30 & 19/33

18/30 & 19/33

18/30 & 19/33

16

50

95

185

25

50

150

35

70

150

50

95

240

400

50

240

400

95

240

400

Different types of screen continuity kits can be supplied.

Please contact our representative.

Kit contentsThe complete GTS3 joint kit comprises the following components:

The kit also comprises installation instructions, semi-conductive tape, adhesive tape, a copper braid, tinned copper mesh tape, armour continuity roll springs and a ferrule for the screen wire connection.

+

Sealing mastic

“NGAF”

Black stress control tube

“GT1”

Stress control mastic

“MNAC”

=+ + XXGTS3straightjoint kit

++

Dual walltube

“GT25”

Overallprotection

tube“GT8”

Canister

+

Protection tube

“GT3”

When jointing cablesof different sizes,

please contact our representative.

For use with single core cables:

see GTS1.

Can be supplied with all common types of

conductor connectors.

For use with copper wire screened cables.No further earthing device is necessary.

For use with other cable types.

Please contact our representative.

Page 5: GTS1 - Awali Joints/HEATSHRINK...20 08/2011 Design 1. Dual wall tube. 2. control tube. Stress 3. control mastic. Stress 4. Non-tracking tube (only for 36GTS1). 5.all protection tube

24

08/2

011

6/10 (12) kV6.35/11 (12) kV8.7/15 (17.5) kV

12/20 (24) kV12.7/22 (24) kV

18/30 (36) kV19/33 (36) kV

Up to 36 kV

GTM3HEAT-SHRINKABLE

THREE CORE TRANSITION JOINT

ApplicationFor jointing three-core paper cables (draining and non-draining) to three core polymeric cables. For use with belted or screened (Höchstädter) cables with a common lead sheath. This transition joint is fully screened, submersible and suitable to be directly buried.

Straight Jointtype

VoltageUm(kV)

Length“L”

(mm)

Conductor sizes(mm2)

min max17GTM3

24GTM3

36GTM3

12 - 17.5

24

36

1200 - 1400

1600 - 1800

1800 - 2100

25

25

35

400

400

400

Specifications and standardsMeets the requirements of CENELEC HD 629.2 andIEC 60502-4.

Design 1. Dual wall tube. 2. Stress control tube. 3. Screen continuity (copper mesh). 4. Stress control mastic. 5. Overall protection tube. 6. Sealing mastic. 7. Canister. 8. Conductor connector (supplied on request). 9. Non-tracking tube (only for 36GTM3 - not shown). 10. Barrier tube. 11. Semi-conductive break-out. 12. Semi-conductive tubes. 13. Stress control mastic. 14. Semi-conductive tape.

5

13

6

14

11

12

10

7

2

1

4

8

3

6

L

Page 6: GTS1 - Awali Joints/HEATSHRINK...20 08/2011 Design 1. Dual wall tube. 2. control tube. Stress 3. control mastic. Stress 4. Non-tracking tube (only for 36GTS1). 5.all protection tube

25

+ +

Black stress control tube

“GT1”

=+ +

Dual walltube

“GT25”

Overallprotection

tube“GT8”

Canister

+

Protection tube

“GT3”

Ordering instructionsSelect the part number corresponding to both system voltage and cable dimensions.

Example:The three core belted cable is12 kV, 3 x 150 mm², non-draining, armoured and must be jointed to a three core 12 kV, 150 mm² XLPE cable.Order: 17GTM3.240K.

Orderingpart

number

VoltageU0/U(kV)

Conductor size range(mm2)

min max

17GTM3.50K

17GTM3.95K

17GTM3.240K

17GTM3.400K

24GTM3.50K

24GTM3.240K

24GTM3.400K

36GTM3.95K

36GTM3.240K

36GTM3.400K

6/10 and 8.7/15

6/10 and 8.7/15

6/10 and 8.7/15

6/10 and 8.7/15

12/20

12/20

12/20

18/30

18/30

18/30

16

50

95

240

25

50

150

35

70

150

50

95

240

400

50

240

400

95

240

400

For transition to threesingle core

XLPE cables: see GTM.3.1.

Different armour connections are

available. Please contact our

representative.

Kit contentsThe complete GTM3 joint kit comprises the following components:

The kit also comprises installation instructions, semi-conductive tape, Hi-K mastic, sealing mastic “NGAF”, adhesive tape, copper braid, tinned copper mesh tape, armour continuity and roll springs.

XXGTM3transition joint kit

For use with other cable types.

Please contact our representative.

+ +

Barriertube

“GT10”

Can be supplied with all common types of

conductor connectors.

For use withPICAS cables.

Please contact our representative.

When jointing cables of different sizes,

please contact our representative.

Semi-conductive break-out“36TTS”

Semi-conductive

tube“GT5”

Page 7: GTS1 - Awali Joints/HEATSHRINK...20 08/2011 Design 1. Dual wall tube. 2. control tube. Stress 3. control mastic. Stress 4. Non-tracking tube (only for 36GTS1). 5.all protection tube

26

08/2

011

6/10 (12) kV6.35/11 (12) kV8.7/15 (17.5) kV

12/20 (24) kV12.7/22 (24) kV

18/30 (36) kV19/33 (36) kV

Specifications and standardsMeets the requirements of CENELEC HD 629.2 andIEC 60502-4.

Up to 36 kV

GTM3.1HEAT-SHRINKABLE

THREE CORE TRANSITION JOINT

ApplicationFor jointing three-core paper cables (draining and non-draining) to three single core polymeric cables. For use with belted or screened (Höchstädter) cables with a common lead sheath. This transition joint is fully screened, submersible and suitable to be directly buried.

Straight Jointtype

VoltageUm(kV)

Length“L”

(mm)

Conductor sizes(mm2)

min max17GTM3.1

24GTM3.1

36GTM3.1

12 - 17.5

24

36

1800

1800

1800 - 2300

25

25

35

400

400

400

Design 1. Dual wall tube. 2. Stress control tube. 3. Protection tube. 4. Hi-K mastic. 5. Sealing mastic. 6. Screen continuity (copper braid and mesh). 7. Conductor connector (supplied on request). 8. Semi-conductive break-out. 9. Semi-conductive tubes. 10. Barrier tube. 11. Break-out.

3

3

8

10

5

4

6

9

7

1

2

4

5

11

L

Page 8: GTS1 - Awali Joints/HEATSHRINK...20 08/2011 Design 1. Dual wall tube. 2. control tube. Stress 3. control mastic. Stress 4. Non-tracking tube (only for 36GTS1). 5.all protection tube

27

Ordering instructionsSelect the part number corresponding to both system voltage and cable dimensions.

Example:The three core belted cable is 12 kV, 3 x 150 mm², non-draining, armoured and must be jointed to a three single core12 kV, 150 mm² XLPE cables.Order: 17GTM3.1.240i.

Orderingpart

number

VoltageU0/U(kV)

Conductor size range(mm2)

min max

17GTM3.1.50W

17GTM3.1.95W

17GTM3.1.240W

17GTM3.1.400W

24GTM3.1.50W

24GTM3.1.240W

24GTM3.1.400W

36GTM3.1.95i

36GTM3.1.240i

36GTM3.1.400i

6/10 and 8.7/15

6/10 and 8.7/15

6/10 and 8.7/15

6/10 and 8.7/15

12/20

12/20

12/20

18/30

18/30

18/30

25

50

95

240

25

50

150

35

70

150

50

95

240

400

50

240

400

95

240

400

When jointing cables of different sizes,

please contact our representative.

For use withPICAS cables.

Please contact our representative.

For use with other cable types,

please contact our representative.

For transition to three core XLPE cables:

see GTM3.

Can be supplied with all common types of

conductor connectors.

Different armour connections are

available. Please contact our

representative.

Kit contentsThe complete GTM3.1 joint kit comprises the following components:

The kit also comprises installation instructions, semi-conductive tape, Hi-K mastic, stress control mastic, sealing mastic “NGAF”, adhesive tape, copper braid, tinned copper mesh tape, armour continuity and roll springs.

+

Semi-conductive tube “GT5”

Protection tube

“GT3”

=+ XXGTM3.1transitionjoint kit

+

Dual walltube

“GT25”

Barriertube

“GT10”

+

Break-out“36TTE”

Black stress control

tube “GT1”

++

Semi-conductive break-out“36TTS”

Page 9: GTS1 - Awali Joints/HEATSHRINK...20 08/2011 Design 1. Dual wall tube. 2. control tube. Stress 3. control mastic. Stress 4. Non-tracking tube (only for 36GTS1). 5.all protection tube

28

08/2

011

Design 1. Dual wall tube. 2. Hi-K mastic. 3. Stress control tube. 4. Conductor connector (supplied on request). 5. Semi-conductive break- out. 6. Barrier tube. 7. Semi-conductive tubes. 8. Canister. 9. Screen continuity (copper braid and mesh). 10. Overall protection tubes.

6/10 (12) kV6.35/11 (12) kV8.7/15 (17.5) kV

12/20 (24) kV12.7/22 (24) kV

18/30 (36) kV19/33 (36) kV

Specifications and standardsMeets the requirements of CENELEC HD 629.2 andIEC 60502-4.

Up to 36 kV

GTC3HEAT-SHRINKABLE THREE CORE PILCSTRAIGHT JOINT

Straight Jointtype

VoltageUm(kV)

Length“L”

(mm)

Conductor sizes(mm2)

min max

17GTC3

24GTC3

36GTC3

12 - 17.5

24

36

1800

1600 - 1800

1800 - 2100

25

25

35

240

400

400

ApplicationFor jointing three-core paper cables (draining and non-draining). For use with belted or screened (Höchstädter) cables with a common lead sheath. This joint is fully screened, submersible and suitable to be directly buried.

4

2

1

3

8

7

6

5

9

2

10

L

Page 10: GTS1 - Awali Joints/HEATSHRINK...20 08/2011 Design 1. Dual wall tube. 2. control tube. Stress 3. control mastic. Stress 4. Non-tracking tube (only for 36GTS1). 5.all protection tube

29

Ordering instructionsSelect the part number corresponding to both system voltage and conductor size.

Example:The cable is 24 kV, 3 x 120 mm2 stranded aluminium, with non-draining paper insulation.It has an individual tape screen and a steel wire armour.Order: 24GTC3.240k.

Orderingpart

number

VoltageU0/U(kV)

Conductor size range(mm2)

min max

17GTC3.50k

17GTC3.95k

17GTC3.240k

17GTC3.400k

24GTC3.50k

24GTC3.240k

24GTC3.400k

36GTC3.95k

36GTC3.240k

36GTC3.400k

6/10 and 8.7/15

6/10 and 8.7/15

6/10 and 8.7/15

6/10 and 8.7/15

12/20

12/20

12/20

18/30

18/30

18/30

16

50

95

240

25

50

150

35

70

150

50

95

240

400

50

240

400

95

240

400

Kit contentsThe complete GTC3 joint kit comprises the following components:

= XXGTC3straightjoint kit

+

Protection tube

“GT8”

+

Canister

The kit also comprises installation instructions, semi-conductive tape, Hi-K and stress control mastic, sealing mastic “NGAF”, adhesive tape, copper braid, tinned copper mesh tape, armour continuity and roll springs.

When jointing cables of different sizes,

please contact our representative.

For use withPICAS cables.

Please contact our representative.

For use with individual lead screened cables,please contact our

representative.

Can be supplied with all common types of

conductor connectors.

For use withXLPE cables: see GTS3.

For use with single core cables,

please contact our representative.

Semi-conductive tube “GT5”

+

2 x Protection tube

“GT3”

Dual walltube

“GT25”

Barriertube

“GT10”

+++

2 x Semi-conductive break-out“36TTS”