16
Hai Nam Switchboard Manufacture Co., Ltd.

Hai Nam Switchboard Manufacture Co., Ltd. · 14 Circuit-Breaker Switchgear Type SIMOPRIME A4, up to 24 kV, Air-Insulated t Responsible for Technical director : Mr. Vu Nhu Y Hai Nam

  • Upload
    others

  • View
    9

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Hai Nam Switchboard Manufacture Co., Ltd. · 14 Circuit-Breaker Switchgear Type SIMOPRIME A4, up to 24 kV, Air-Insulated t Responsible for Technical director : Mr. Vu Nhu Y Hai Nam

Hai Nam Switchboard Manufacture Co., Ltd.

Page 2: Hai Nam Switchboard Manufacture Co., Ltd. · 14 Circuit-Breaker Switchgear Type SIMOPRIME A4, up to 24 kV, Air-Insulated t Responsible for Technical director : Mr. Vu Nhu Y Hai Nam
Page 3: Hai Nam Switchboard Manufacture Co., Ltd. · 14 Circuit-Breaker Switchgear Type SIMOPRIME A4, up to 24 kV, Air-Insulated t Responsible for Technical director : Mr. Vu Nhu Y Hai Nam

3

Page 4: Hai Nam Switchboard Manufacture Co., Ltd. · 14 Circuit-Breaker Switchgear Type SIMOPRIME A4, up to 24 kV, Air-Insulated t Responsible for Technical director : Mr. Vu Nhu Y Hai Nam

4

Page 5: Hai Nam Switchboard Manufacture Co., Ltd. · 14 Circuit-Breaker Switchgear Type SIMOPRIME A4, up to 24 kV, Air-Insulated t Responsible for Technical director : Mr. Vu Nhu Y Hai Nam

5

Technical DataRatings

Page 6: Hai Nam Switchboard Manufacture Co., Ltd. · 14 Circuit-Breaker Switchgear Type SIMOPRIME A4, up to 24 kV, Air-Insulated t Responsible for Technical director : Mr. Vu Nhu Y Hai Nam

Insulated Circuit-Breaker Switchgear Type SIMOPRIME A4, up to 24 kV, Air-6

Classification of the SIMOPRIME A4 switchgear according to IEC 62271-200

Internal arc classification Classification IAC Accessibility – Front – Rear – Lateral

Type A Type A Type A

Test current kA Arc duration s

25 1.0

Dimensions All panel types Dimensions in mm

Width B Circuit-breaker panel for 1250 A for 2000 A

1000

Load Break Switch 500

Height H With standard low-voltage compartment and IAC 0.1 s 2250

Depth T Standard 1900

Construction and design Partition class Loss of service continuity category

PM (metallic partition) LSC2B (metal-clad)

Compartment accessibility (standard) – Busbar compartment – Switching-device compartment – Low-voltage compartment – Connection compartment

– Rear connection

Interlock-controlled and Tool-based Tool-based

Room planning (room height ≥ 2850 mm) Front connection

Single-row arrangement (plan view) For dimensions B (width) and T (depth) refer to table on this page 1) For panel replacement: Control aisle 2000 mm 2) Minimum distance to wall 150 mm

Technical DataClassification, dimensions, room planning

– Front connection

Tool-basedInterlock-controlledTool-based

800

Page 7: Hai Nam Switchboard Manufacture Co., Ltd. · 14 Circuit-Breaker Switchgear Type SIMOPRIME A4, up to 24 kV, Air-Insulated t Responsible for Technical director : Mr. Vu Nhu Y Hai Nam

7

Page 8: Hai Nam Switchboard Manufacture Co., Ltd. · 14 Circuit-Breaker Switchgear Type SIMOPRIME A4, up to 24 kV, Air-Insulated t Responsible for Technical director : Mr. Vu Nhu Y Hai Nam

8

Page 9: Hai Nam Switchboard Manufacture Co., Ltd. · 14 Circuit-Breaker Switchgear Type SIMOPRIME A4, up to 24 kV, Air-Insulated t Responsible for Technical director : Mr. Vu Nhu Y Hai Nam

9

Page 10: Hai Nam Switchboard Manufacture Co., Ltd. · 14 Circuit-Breaker Switchgear Type SIMOPRIME A4, up to 24 kV, Air-Insulated t Responsible for Technical director : Mr. Vu Nhu Y Hai Nam

10

Page 11: Hai Nam Switchboard Manufacture Co., Ltd. · 14 Circuit-Breaker Switchgear Type SIMOPRIME A4, up to 24 kV, Air-Insulated t Responsible for Technical director : Mr. Vu Nhu Y Hai Nam

11

Page 12: Hai Nam Switchboard Manufacture Co., Ltd. · 14 Circuit-Breaker Switchgear Type SIMOPRIME A4, up to 24 kV, Air-Insulated t Responsible for Technical director : Mr. Vu Nhu Y Hai Nam

12

Page 13: Hai Nam Switchboard Manufacture Co., Ltd. · 14 Circuit-Breaker Switchgear Type SIMOPRIME A4, up to 24 kV, Air-Insulated t Responsible for Technical director : Mr. Vu Nhu Y Hai Nam

13

Certificate

Page 14: Hai Nam Switchboard Manufacture Co., Ltd. · 14 Circuit-Breaker Switchgear Type SIMOPRIME A4, up to 24 kV, Air-Insulated t Responsible for Technical director : Mr. Vu Nhu Y Hai Nam

Circuit-Breaker Switchgear Type SIMOPRIME A4, up to 24 kV, Air-Insulated 14

Responsible for

Technical director : Mr. Vu Nhu YHai Nam Switchboard Manufacture Co., Ltd

Hai Nam Switchboard Manufacture Co., Ltd General editing: Mr. Leo Lumbantoruan

Notes If not stated otherwise on the individual pages of this catalog, we reserve the right to include modifications, especially regarding the stated values, dimensions and weights. Drawings are not binding. All product designations used are trademarks or product names of Siemens AG or other suppliers. If not stated otherwise, all dimensions in this catalog are given in mm. The information in this document contains general descriptions of the technical options available, which do not always have to be present in individual cases. The required features should therefore be specified in each individual case at the time of closing the contract.

Notes

Hai Nam Switchboard Manufacture Co., Ltd.

Page 15: Hai Nam Switchboard Manufacture Co., Ltd. · 14 Circuit-Breaker Switchgear Type SIMOPRIME A4, up to 24 kV, Air-Insulated t Responsible for Technical director : Mr. Vu Nhu Y Hai Nam
Page 16: Hai Nam Switchboard Manufacture Co., Ltd. · 14 Circuit-Breaker Switchgear Type SIMOPRIME A4, up to 24 kV, Air-Insulated t Responsible for Technical director : Mr. Vu Nhu Y Hai Nam

Hai Nam Switchboard Manufacture Co., Ltd.VIETNAMLot No. C 32, Road No. 9, Hiep Phuoc IP,Nha Be District, HCMC, VietnamTel: +84 8 3 873 4066 | Fax: +84 8 3 873 4067Hotline: +84 90 23 23 475 - 90 23 23 495

Branch Office:Lot No. 45, Quang Minh IP, Me Linh,Ha Noi City, VietnamTel: + 84 4 38 133 011Fax: + 84 4 38 133 010

Website: www.hainamswitchboards.comEmail: [email protected]

CAMBODIAStreet #30m (National Road #3), PreyKeyKor Village, PongToek Commune, DangKor Dist., Phnom Penh City, Kingdom of CambodiaTel: + 85 5 2 398 2161 | Fax: + 85 5 2 398 2162

MYANMAR No. 18 Kyaik Khaut Pagoda Road, Thanlyin Township,Yangon, MyanmarTel.: +95) 562 3177 / +95 92 5324 7697 (Myanmar) (+84) 948 676 068 (Viet Nam)

Printed by Hai Nam