Copyright © 2002-2007 WTCA – Representing the Structural Building Components Industry. All Rights Reserved. TTBPLACE-070703
How to Read a Truss Placement Diagram Como Leer un Diagrama de Instalación de Trusses
A Truss Placement Diagram is an illustration identifying the assumed location for each truss based on the Truss Manufacturer’s interpretation of the Construction Documents. Installation details, hanger schedule, job information, on-center spacing and special truss locations are optional information that may be included on the Truss Placement Diagram by the Truss Manufacturer.El Diagrama de Instalación de Trusses es una illustración que identifica la supuesta ubicación de cada truss basada en la interpretación que el Fabricante de Trusses hace de los Documentos de Construcción. El Fabricante de Trusses puede incluir información opcional en el Diagrama de Instalación de Trusses como las detalles de instalación, el horario de colgadores soportantes, la información del trabajo, el espaciamiento del centro y las ubicaciones especiales de los trusses.
THIS
IS A
TRU
SS P
LAC
EMEN
T D
IAG
RA
M O
NLY
.
WA
RN
ING
!BC
SI-B
1 SU
MM
ARY
SHEE
T -
GUID
E FO
R HA
NDLI
NG, I
NSTA
LLIN
G, R
ESTR
AINI
NG A
ND B
RACI
NG O
F TRU
SSES
(20
06 E
DITI
ON)
¡AD
VER
TEN
CIA!
HOJA
RES
UMEN
DE
LA G
UÍA
DE B
UENA
PRÁ
CTIC
A PA
RA E
L MAN
EJO,
INST
ALAC
IÓN,
RES
TRIC
CIÓN
Y A
RRIO
STRE
DE
LOS
TRUS
SES
(200
6 ED
ICIÓ
N)
LATE
RAL
RES
TRAI
NT
& D
IAG
ON
AL B
RAC
ING
ARE
VER
Y IM
POR
TAN
T
¡LA
RES
TRIC
CIÓ
N
LATE
RAL
Y E
L
ARR
IOST
RE
DIA
GO
NAL
SON
MU
Y
IMPO
RTA
NTE
S!
Web
Mem
bers
10'-1
5' m
ax. S
ame
spac
ing
as
botto
m c
hord
Lat
eral
Res
train
t
Diag
onal
Bra
ces
ever
y 10
trus
s sp
aces
(20
' max
.)
Som
e ch
ord
and
web
mem
bers
not
show
n fo
r cl
arit
y.
Diag
onal
Brac
ing
Botto
m C
hord
s
Trus
ses
are
not m
arke
d in
any
way
to id
entif
y
the
frequ
ency
or l
ocat
ion
of te
mpo
rary
late
ral
rest
rain
t and
dia
gona
l bra
cing
. Fol
low
the
reco
mm
enda
tions
for h
andl
ing,
inst
allin
g an
d
tem
pora
ry re
stra
inin
g an
d br
acin
g of
trus
ses.
Refe
r to
BCSI
Gui
de to
Goo
d Pr
actic
e fo
r
Hand
ling,
Inst
allin
g, R
estra
inin
g &
Brac
ing
of
Met
al P
late
Con
nect
ed W
ood
Trus
ses
for m
ore
deta
iled
info
rmat
ion.
Trus
s De
sign
Draw
ings
may
spe
cify
loca
tions
of
perm
anen
t la
tera
l res
train
t or
rei
nfor
cem
ent
for
indi
vidu
al t
russ
mem
bers
. Re
fer
to t
he B
CSI-
B3
Sum
mar
y Sh
eet
– Pe
rman
ent
Rest
rain
t/Br
acin
g
of C
hord
s &
Web
Mem
bers
for m
ore
info
rmat
ion.
All
othe
r pe
rman
ent
brac
ing
desig
n is
the
resp
onsib
ility
of t
he B
uild
ing
Desig
ner.
GEN
ERAL
NO
TES
HAN
DLI
NG
— M
ANEJ
O
INST
ALLA
TIO
NO
FSI
NG
LETR
USS
ESBY
HAN
D
INST
ALAC
IÓN
POR
LA
MAN
O D
E TR
USS
ES I
ND
IVID
UAL
ES
HO
ISTI
NG
OF
SIN
GLE
TRU
SSES
— L
EVAN
TAM
IEN
TO D
E TR
USS
ES I
ND
IVID
UAL
ES
RES
TRAI
NT/
BRAC
ING
FOR
ALL
PLAN
ESO
FTR
USS
ES
RES
TRAI
NT
& B
RAC
ING
FOR
3x2
AND
4x2
PAR
ALLE
L CH
OR
D T
RU
SSES
LA R
ESTR
ICCI
ÓN
Y E
L AR
RIO
STR
E PA
RA
TRU
SSES
DE
CUER
DAS
PAR
ALEL
AS 3
X2 Y
4X2
ALTE
RAT
ION
S —
ALT
ERAC
ION
ES
Trus
ses
that
hav
e be
en o
verlo
aded
dur
ing
cons
truc
tion
or a
ltere
d w
ithou
t the
Tru
ss M
anuf
actu
rer’s
prio
r app
rova
l may
rend
er th
e Tr
uss
Man
ufac
ture
r’s li
mite
d w
arra
nty
null
and
void
.
Trus
ses
que
se h
an s
obre
carg
ado
dura
nte
la c
onst
rucc
ión
o ha
n sid
o al
tera
dos
sin u
na a
utor
izació
n
prev
ia d
el F
abric
ante
de
Trus
ses,
pue
den
redu
cir o
elim
inar
la g
aran
tía d
el F
abric
ante
de
Trus
ses.
Do n
ot p
roce
ed w
ith c
onst
ruct
ion
until
all
late
ral r
estra
int a
nd
brac
ing
is se
cure
ly a
nd p
rope
rly in
pla
ce.
No p
roce
da c
on la
con
stru
cció
n ha
sta
que
toda
s la
s re
stric
-
cion
es la
tera
les
y lo
s ar
riost
res
esté
n co
loca
dos
en fo
rma
apro
piad
a y
segu
ra.
Trus
ses
20'
or le
ss, s
up-
port
at p
eak.
Leva
nte
del p
ico
los
trus
ses
de
20 p
ies
o
men
os.
Trus
ses
30' o
r
less
, sup
port
at
quar
ter p
oint
s.
Leva
nte
de
los
cuar
tos
de tr
amo
los
trus
ses
de 3
0
pies
o m
enos
.
TRU
SSES
UP
TO 3
0'
TRU
SSES
HAS
TA 3
0 PI
ES
INST
ALLI
NG
— I
NST
ALAC
ION
Tole
ranc
es fo
r
Out
-of-P
lum
b.
Tole
ranc
ias
para
Fuer
a-de
-Plo
mad
a.
Tole
ranc
es fo
r Out
-of-P
lane
.
Tole
ranc
ias
para
Fue
ra-d
e-Pl
ano.
Plac
e lo
ads
over
as
man
y tr
usse
s as
pos
sible
.
Colo
que
las
carg
as s
obre
tant
os tr
usse
s co
mo
sea
posib
le.
Po
sitio
n lo
ads
over
load
bea
ring
wal
ls.
Colo
que
las
carg
as s
obre
las
pare
des
sopo
rtan
tes.
Refe
r to
BCSI
-B5
Sum
mar
y Sh
eet -
Tru
ss D
amag
e, J
obsit
e M
odifi
catio
ns &
Inst
alla
tion
Erro
rs.
Vea
el re
súm
en B
CSI-
B5 D
años
de
trus
ses,
Mod
ifica
cion
es e
n la
Obr
a y
Erro
res
de In
stal
ació
n.
Do n
ot e
xcee
d m
axim
um s
tack
hei
ghts
. Ref
er to
BCS
I-B4
Sum
mar
y Sh
eet -
Con
stru
ctio
n Lo
adin
g fo
r mor
e in
form
atio
n.
No e
xced
a la
s m
áxim
as a
ltura
s re
com
enda
das.
Vea
el r
esúm
en
BCSI
-B4
Carg
a de
Con
stru
cció
n pa
ra m
ayor
info
rmac
ión.
Do n
ot o
verlo
ad s
mal
l gro
ups
or s
ingl
e tr
usse
s.
No s
obre
carg
ue p
eque
ños
grup
os o
trus
ses
indi
vidu
ales
.
Refe
r to
BCSI
-B7
Sum
mar
y Sh
eet
- Tem
pora
ry &
Per
-
man
ent R
estra
int/
Brac
ing
for P
aral
lel
Chor
d Tr
usse
s fo
r
mor
e in
form
atio
n.
Vea
el re
sum
en
BCSI
-B7
– Re
stric
-
ción
y A
rrio
stre
Tem
pora
l y
Perm
anen
te d
e
Trus
ses
de C
uerd
as
Para
lela
s pa
ra m
ás
info
rmac
ión. CO
NST
RU
CTIO
N L
OAD
ING
— C
ARG
A D
E CO
NST
RU
CCIO
N
This document summarizes the information provided in Section B1 of the 2006 Edition of Building Component Safety Information BCSI - Guide to Good Practice for Handling, Installing, Restraining & Bracing of Metal Plate Connected Wood Trusses.
Copyright © 2004-2006 WTCA – Representing the Structural Building Components Industry and Truss Plate Institute. All Rights Reserved. This guide or any part thereof may not be reproduced in any form without the written permission of the publishers. Printed in the United States of America.
Los
truss
es n
o es
tán
mar
cado
s de
nin
gún
mod
o qu
e
iden
tifiqu
e la f
recu
encia
o lo
caliz
ació
n de
rest
ricció
n lat
eral
y ar
riost
re d
iagon
al te
mpo
rales
. Use
las r
ecom
enda
cione
s
de m
anej
o, in
stala
ción,
rest
ricció
n y
arrio
stre
tem
pora
l de
los
truss
es.
Vea
el fo
lleto
BCS
I Gu
ía de
Bue
na P
ráct
ica
para
el M
anej
o, In
stala
ción,
Res
tricc
ión
y Ar
riost
re d
e lo
s
Trus
ses
de M
ader
a Co
nect
ados
con
Plac
as d
e M
etal
para
info
rmac
ión
más
det
allad
a.
Los d
ibuj
os d
e di
seño
de
los t
russ
es p
uede
n es
pecifi
car l
as
loca
lizac
ione
s de
rest
ricció
n lat
eral
perm
anen
te o
refu
erzo
en l
os m
iembr
os i
ndivi
duale
s de
l tru
ss.
Vea
la ho
ja
resu
men
BCS
I-B3
–Re
stric
ción/
Arrio
stre
Per
man
ente
de
Cuer
das
y M
iembr
os S
ecun
dario
s pa
ra m
ás in
form
ació
n.
El re
sto
de lo
s di
seño
s de
arri
ostre
s pe
rman
ente
s so
n la
resp
onsa
bilid
ad d
el Di
seña
dor d
el Ed
ificio
.
NO
TAS
GEN
ERAL
ES
The
cons
eque
nces
of i
mpr
oper
han
dlin
g, e
rect
-
ing,
inst
allin
g, re
stra
inin
g an
d br
acin
g ca
n re
sult
in a
col
laps
e of
the
stru
ctur
e, o
r wor
se, s
erio
us
pers
onal
inju
ry o
r dea
th.
El
resu
ltado
de
un m
anej
o, le
vant
amie
nto,
inst
alac
ión,
rest
ricci
ón y
arr
isotr
e in
corr
ecto
pue
de
ser l
a ca
ída
de la
est
ruct
ura
o aú
n pe
or, h
erid
oso
mue
rtos
.
Band
ing
and
trus
s pl
ates
hav
e sh
arp
edge
s. W
ear
glov
es w
hen
hand
ling
and
safe
ty g
lass
es w
hen
cutti
ng b
andi
ng.
Em
paqu
es y
pla
cas
de m
etal
tien
en b
orde
s
afila
dos.
Use
gua
ntes
y le
ntes
pro
tect
ores
cua
ndo
cort
e lo
s em
paqu
es.
Use
spec
ial c
are
in
win
dy w
eath
er o
r
near
pow
er li
nes
and
airp
orts
.
Utili
ce c
uida
do
espe
cial
en
días
vent
osos
o c
erca
de
cabl
es e
léct
ricos
o d
e
aero
puer
tos.
Do n
ot s
tore
on
unev
en g
roun
d.
No a
lmac
ene
en
tierr
a de
sigua
l.
Do n
ot s
tore
unbr
aced
bun
dles
uprig
ht.
No a
lmac
ene
vert
ical
men
te lo
s
trus
ses
suel
tos.
Avoi
d la
tera
l ben
ding
. — E
vite
la fl
exió
n la
tera
l.
TRU
SSES
UP
TO 6
0'
TRU
SSES
HAS
TA 6
0 PI
ES
HO
ISTI
NG
REC
OM
MEN
DAT
ION
S FO
RSI
NG
LE
TRU
SSES
REC
OM
END
ACIO
NES
PAR
A LE
VAN
TAR
TR
USS
ES
IND
IVID
UAL
ES TEM
POR
ARY
RES
TRAI
NT
& B
RAC
ING
RES
TRIC
CIÓ
N Y
AR
RIO
STR
E TE
MPO
RAL
Refe
r to
BCSI
-B2
Sum
mar
y Sh
eet –
Tru
ss
Inst
alla
tion
& Te
mpo
rary
Res
train
t/Br
acin
g fo
r
mor
e in
form
atio
n.
Vea
el re
sum
en B
CSI
B2 –
Res
tric
ción
/
Arrio
stre
Tem
pora
l y In
stal
ació
n de
los
Trus
ses
para
más
info
rmac
ión. Do
not
wal
k on
unb
race
d
trus
ses.
No c
amin
e en
trus
ses
suel
tos.
Lo
cate
gro
und
brac
es fo
r firs
t tru
ss d
irect
ly in
line
with
all
row
s of
top
chor
d te
mpo
rary
lat-
eral
rest
rain
t (se
e ta
ble
in th
e ne
xt c
olum
n).
Colo
que
los
arrio
stre
s de
tier
ra p
ara
el p
rimer
trus
s di
rect
amen
te e
n lín
ea c
on c
ada
una
de
las
filas
de
rest
ricci
ón la
tera
l tem
pora
l de
la
cuer
da s
uper
ior (
vea
la ta
ble
en la
pró
xim
a
colu
mna
).
This
rest
rain
t & b
raci
ng m
etho
d is
for a
ll tr
usse
s ex
cept
3x2
and
4x2
par
alle
l cho
rd tr
usse
s.
Es
te m
étod
o de
rest
ricci
ón y
arr
iost
re e
s pa
ra to
do tr
usse
s ex
cept
o tr
usse
s de
cue
rdas
par
alel
as
3x2
y 4x
2.
Do n
ot c
ut, a
lter,
or d
rill a
ny s
truc
tura
l mem
ber o
f a tr
uss
unle
ss
spec
ifica
lly p
erm
itted
by
the
Trus
s De
sign
Draw
ing.
No c
orte
, alte
re o
per
fore
nin
gún
mie
mbr
o es
truc
tura
l de
los
trus
ses,
a m
enos
que
est
é es
pecí
ficam
ente
per
miti
do e
n el
dib
ujo
del d
iseño
del
trus
s.
If tr
usse
s ar
e to
be
stor
ed h
orizo
ntal
ly, p
lace
bloc
king
of s
uffic
ient
hei
ght b
enea
th th
e
stac
k of
trus
ses
at 8
’ to
10’ o
n ce
nter
.
For t
russ
es s
tore
d fo
r mor
e th
an o
ne w
eek,
cove
r bun
dles
to p
reve
nt m
oist
ure
gain
but
allo
w fo
r ven
tilat
ion.
Refe
r to
BCSI
Gui
de to
Goo
d Pr
actic
e fo
r
Hand
ling,
Inst
allin
g, R
estra
inin
g &
Brac
ing
of M
etal
Pla
te C
onne
cted
Woo
d Tr
usse
s
for m
ore
deta
iled
info
rmat
ion
pert
aini
ng to
hand
ling
and
jobs
ite s
tora
ge o
f tru
sses
.
Si lo
s tr
usse
s es
tará
n gu
arda
dos
horiz
on-
talm
ente
, pon
ga b
loqu
eand
o de
altu
ra
sufic
ient
e de
trás
de
la p
ila d
e lo
s tr
usse
s.
Para
trus
ses
guar
dado
s po
r más
de
una
sem
ana,
cub
ra lo
s pa
quet
es p
ara
prev
enir
aum
ento
de
hum
edad
per
o pe
rmita
ven
ti-
laci
ón.
Vea
el fo
lleto
BCS
I Gu
ía d
e Bu
ena
Prác
tica
para
el M
anej
o, In
stal
ació
n, R
estr
icci
ón y
Ar-
riost
res
de lo
s Tr
usse
s de
Mad
era
Cone
ctad
os
con
Plac
as d
e M
etal
par
a in
form
ació
n m
ás
deta
llada
sob
re e
l man
ejo
y al
mac
enad
o de
los
trus
ses
en á
rea
de tr
abaj
o.
Trus
ses
up to
20'
Trus
ses
hast
a 20
pie
s
Trus
ses
up to
30'
Trus
ses
hast
a 30
pie
s
2) W
EB M
EMBE
R P
LAN
E —
PLA
NO
DE
LOS
MIE
MBR
OS
SECU
ND
ARIO
S
Us
e pr
oper
rig-
ging
and
hoi
stin
g
equi
pmen
t.
Use
equi
po a
prop
iado
para
leva
ntar
e
impr
ovisa
r.
Brac
e fir
st tr
uss
secu
rely
bef
ore
erec
tion
of a
dditi
onal
trus
ses.
B1W
ARN
11x1
7 20
0611
15
Refe
r to
BCSI
-B3
Sum
-
mar
y Sh
eet –
Per
man
ent
Rest
rain
t/Br
acin
g of
Cho
rds
& W
eb M
embe
rs fo
r Gab
le
End
Fram
e re
stra
int/
brac
ing/
rein
forc
emen
t inf
orm
atio
n.
Para
info
rmac
ión
sobr
e
rest
ricci
ón/a
rrio
stre
/ref
uerz
o
para
arm
azón
de
hast
ial v
ea
el re
sum
en B
CSI-
B3 –
Re-
stric
ción
/Arr
iost
re
Perm
anen
te d
e Cu
erda
s y
Mie
mbr
os S
ecun
dario
s.
Trus
s Sp
an
Long
itud
de
Tram
o
Top
Chor
d Te
mpo
rary
Lat
eral
Res
trai
nt (
TCTL
R)
Spac
ing
Espa
ciam
ient
o de
l Arr
iost
re T
empo
ral d
e la
Cue
rda
Supe
rior
Up to
30'
Hast
a 30
pie
s
10' o
.c. m
ax.
10 p
ies
máx
imo
30' t
o 45
'
30 a
45
pies
8' o
.c. m
ax.
8 pi
es m
áxim
o
45' t
o 60
'
45 a
60
pies
6' o
.c. m
ax.
6 pi
es m
áxim
o
60' t
o 80
'*
60 a
80
pies
*
4' o
.c. m
ax.
4 pi
es m
áxim
o
1) T
OP
CHO
RD
— C
UER
DA
SUPE
RIO
R
See
BCSI
-B2
for T
CTLR
opt
ions
.
Vea
el B
CSI-
B2 p
ara
las
opci
ones
de
TCTL
R.
Re
peat
dia
gona
l
brac
es fo
r eac
h se
t of
4 tr
usse
s.
Repi
ta lo
s ar
risot
res
diag
onal
es p
ara
cada
grup
o de
4 tr
usse
s.
War
ning
! Usin
g a
singl
e pi
ck-p
oint
at t
he p
eak
can
dam
age
the
trus
s.
¡A
dver
tenc
ia! E
l uso
de
un s
olo
luga
r par
a
leva
ntar
en
el p
ico
pued
e ha
cer d
año
al tr
uss.
NO
TE:
The
Trus
s M
anuf
actu
rer
and
Trus
s De
signe
r re
ly o
n th
e pr
esum
ptio
n th
at t
he C
ontra
ctor
and
cra
ne o
pera
tor
(if a
pplic
able
) ar
e
prof
essio
nals
with
the
capa
bilit
y to
und
erta
ke th
e w
ork
they
hav
e ag
reed
to d
o on
any
giv
en p
roje
ct. I
f the
Con
tract
or b
elie
ves
it ne
eds
assis
tanc
e in
som
e as
pect
of t
he c
onst
ruct
ion
proj
ect,
it sh
ould
see
k as
sista
nce
from
a c
ompe
tent
par
ty. T
he m
etho
ds a
nd p
roce
dure
s
outli
ned
in th
is do
cum
ent a
re in
tend
ed to
ens
ure
that
the
over
all c
onst
ruct
ion
tech
niqu
es e
mpl
oyed
will
put
the
trus
ses
into
pla
ce S
AFEL
Y.
Thes
e re
com
men
datio
ns f
or h
andl
ing,
inst
allin
g, r
estra
inin
g an
d br
acin
g tr
usse
s ar
e ba
sed
upon
the
col
lect
ive
expe
rienc
e of
lead
ing
pers
onne
l inv
olve
d w
ith tr
uss
desig
n, m
anuf
actu
re a
nd in
stal
latio
n, b
ut m
ust,
due
to th
e na
ture
of r
espo
nsib
ilitie
s in
volv
ed, b
e pr
esen
ted
only
as
a GU
IDE
for u
se b
y a
qual
ified
Bui
ldin
g De
signe
r or C
ontra
ctor
. It i
s no
t int
ende
d th
at th
ese
reco
mm
enda
tions
be
inte
rpre
ted
as
supe
rior t
o th
e Bu
ildin
g De
signe
r’s d
esig
n sp
ecifi
catio
n fo
r han
dlin
g, in
stal
ling,
rest
rain
ing
and
brac
ing
trus
ses
and
it do
es n
ot p
recl
ude
the
use
of o
ther
equ
ival
ent m
etho
ds fo
r res
train
ing/
brac
ing
and
prov
idin
g st
abili
ty fo
r the
wal
ls, c
olum
ns, fl
oors
, roo
fs a
nd a
ll th
e in
terr
elat
ed
stru
ctur
al b
uild
ing
com
pone
nts
as d
eter
min
ed b
y th
e Co
ntra
ctor
. Thu
s, W
TCA
and
TPI
expr
essly
disc
laim
any
resp
onsib
ility
for d
amag
es
arisi
ng fr
om th
e us
e, a
pplic
atio
n, o
r rel
ianc
e on
the
reco
mm
enda
tions
and
info
rmat
ion
cont
aine
d he
rein
.
6300
Ent
erpr
ise L
ane
• M
adiso
n, W
I 53
719
608/
274-
4849
• w
ww
.sbc
indu
stry
.com
TRU
SS P
LATE
IN
STIT
UTE
218
N. L
ee S
t., S
te. 3
12 •
Ale
xand
ira, V
A 22
314
703/
683-
1010
• w
ww
.tpin
st.o
rgTo
p Ch
ord
Tem
pora
ry
Late
ral R
estra
int
(TCT
LR)
2x4
min
.
≈90
°
Spre
ader
bar
for t
russ
Atta
ch10
' o.c
.m
ax.
TRU
SSES
UP
TOAN
DO
VER
60'
TRU
SSES
HAS
TAY
SOBR
E 60
PIE
S
*Con
sult
a Pr
ofes
siona
l Eng
inee
r for
trus
ses
long
er th
an 6
0'.
*Con
sulte
a u
n in
geni
ero
para
trus
ses
de m
as d
e 60
pie
s.
Gro
und
brac
ing
not
show
n fo
r cl
arit
y.
3) B
OTT
OM
CH
OR
D —
CU
ERD
A IN
FER
IOR
10'-1
5'
max
.
Som
e ch
ord
and
web
mem
bers
not
show
n fo
r cl
arit
y.
Diag
onal
Bra
ces
ever
y
10 tr
uss
spac
es (
20' m
ax.)
Late
ral R
estra
ints
- 2x
4x12
' or
grea
ter l
appe
d ov
er tw
o tr
usse
s.
Botto
m
chor
ds
10' o
r 15'*
All L
ater
al Re
stra
ints
lappe
d at
leas
t tw
o tru
sses
.
Repe
at D
iagon
al Br
acin
g
ever
y 15
trus
s sp
aces
(30')
Diag
onal
Brac
ing
*Top
cho
rd Te
mpo
rary
Lat
eral
Rest
rain
t spa
cing
shall
be
10' o
.c. m
ax. f
or 3
x2 c
hord
s an
d 15
' o.c
. for
4x2
cho
rds.
Appl
y Di
agon
al Br
ace
to
verti
cal w
ebs
at e
nd o
f
cant
ileve
r and
at b
earin
g
loca
tions
.
D/50
D (ft
.)
1/4"
1'
1/2"
2'
3/4"
3'
1"4'
1-1/
4"5'
1-1/
2"6'
1-3/
4"7'
2"≥8
'
Out
of P
lum
bM
ax.
Bow
Trus
s
Leng
th
3/4"
12.5
'
7/8"
14.6
'
1"16
.7'
1-1/
8"18
.8'
1-1/
4"20
.8'
1-3/
8"22
.9'
1-1/
2"25
.0'
1-3/
4"29
.2'
2"≥3
3.3'
Out
of P
lane
Max
imum
Sta
ck H
eigh
t
for M
ater
ial o
n Tr
usse
s
Mat
eria
lHe
ight
Gyp
sum
Boa
rd12
"
Plyw
ood
or O
SB16
"
Asph
alt S
hing
les
2 bu
ndle
s
Conc
rete
Blo
ck 8
"
Clay
Tile
3-4
tiles
high
Neve
r sta
ck m
ater
ials
near
a p
eak.
Nunc
a am
onto
ne m
ater
ial c
erca
del
pic
o.
Trus
s br
acin
g no
t
show
n fo
r clar
ity.
The
cont
ract
or is
resp
onsib
le fo
r pro
perly
rece
ivin
g, u
nloa
ding
and
sto
ring
the
trus
ses
at th
e jo
bsite
.
HO
ISTI
NG
REC
OM
MEN
DAT
ION
S FO
R T
RU
SS B
UN
DLE
S
Neve
r use
ban
ding
alo
ne to
lift
a bu
ndle
.
Do n
ot li
ft a
grou
p of
indi
vidu
ally
ban
ded
bund
les.
War
ning
! Don
’t ov
erlo
ad th
e cr
ane.
¡Adv
erte
ncia
! ¡No
sob
reca
rga
la g
rúa!
A sin
gle
lift p
oint
may
be
used
for b
undl
es
with
trus
ses
up to
45’.
Two
lift p
oint
s m
ay b
e us
ed fo
r bun
dles
with
trus
ses
up to
60’.
Use
at le
ast 3
lift
poin
ts fo
r bun
dles
with
trus
ses
grea
ter t
han
60’.
War
ning
! Do
not o
ver l
oad
supp
ortin
g
stru
ctur
e w
ith tr
uss
bund
le.
Plac
e tr
uss
bund
les
in s
tabl
e po
sitio
n.
REC
OM
END
ACIO
NES
PAR
A LE
VAN
TAR
PAQ
UET
ES D
E TR
USS
ES.
Nunc
a us
e só
lo lo
s em
paqu
es p
ara
leva
ntar
un
paqu
ete.
No le
vant
e un
gru
po d
e em
paqu
es in
divi
dual
es.
Pued
e us
ar d
os p
unto
s de
leva
ntar
par
a
paqu
etes
más
de
60 p
ies.
Use
por l
o m
enos
tres
pun
tos
de le
vant
ar p
ara
paqu
etes
más
de
60 p
ies.
¡Adv
erte
ncia
! No
sobr
ecar
gue
la e
stru
ctur
a
apoy
ada
con
el p
aque
te d
e tr
usse
s.
Puse
paq
uete
s de
trus
ses
en u
na p
osic
ión
esta
ble.
1) In
stal
l gro
und
brac
ing.
2)
Set fi
rst t
russ
and
atta
ch s
ecur
ely
to g
roun
d br
acin
g. 3
) Se
t nex
t 4
trus
ses
with
sho
rt m
embe
r tem
pora
ry la
tera
l res
train
t (se
e be
low
). 4
) In
stal
l top
cho
rd d
iago
nal
brac
ing
(see
bel
ow).
5)
Inst
all w
eb m
embe
r pla
ne d
iago
nal b
raci
ng to
sta
biliz
e th
e fir
st fi
ve tr
usse
s
(see
bel
ow).
6)
Inst
all b
otto
m c
hord
tem
pora
ry la
tera
l res
train
t and
dia
gona
l bra
cing
(se
e be
low
).
7) R
epea
t pro
cess
on
grou
ps o
f fou
r tru
sses
unt
il al
l tru
sses
are
set
.
1) In
stal
e lo
s ar
riost
res
de ti
erra
. 2)
Inst
ale
el p
rimer
o tr
uss
y at
e se
gura
men
te a
l arr
iost
re d
e
tierr
a. 3
) In
stal
e lo
s pr
óxim
os c
uatr
o tr
usse
s co
n re
stric
ción
late
ral t
empo
ral d
e m
iem
bro
cort
o
(vea
aba
jo).
4)
Inst
ale
el a
rrio
stre
dia
gona
l de
la c
uerd
a su
perio
r (ve
a ab
ajo)
. 5)
Inst
ale
arrio
stre
diag
onal
par
a lo
s pl
anos
de
los
mie
mbr
os s
ecun
dario
s pa
ra e
stab
le lo
s pr
imer
os c
inco
trus
ses
(vea
aba
jo).
6)
Inst
ale
la re
stric
ción
late
ral t
empo
ral y
arr
iost
re d
iago
nal p
ara
la c
uerd
a in
ferio
r
(vea
aba
jo).
7)
Repi
ta é
ste
proc
edim
ient
o en
gru
pos
de c
uatr
o tr
usse
s ha
sta
que
todo
s lo
s tr
usse
s
esté
n in
stal
ados
.
STEP
S TO
SET
TIN
G T
RU
SSES
LAS
MED
IDAS
DE
LA I
NST
ALLA
CIÓ
ND
ELO
S TR
USS
ES
Hold
eac
h tr
uss
in p
ositi
on w
ith th
e er
ectio
n eq
uipm
ent u
ntil
top
chor
d te
mpo
rary
late
ral r
estra
int
is in
stal
led
and
the
trus
s is
fast
ened
to th
e be
arin
g po
ints
.
Sost
enga
cad
a tr
uss
en p
osic
ión
con
equi
po d
e gr
úa h
asta
que
la re
stric
ción
late
ral t
empo
ral d
e la
cuer
da s
uper
ior e
sté
inst
alad
o y
el tr
uss
está
ase
gura
do e
n lo
s so
port
es.
Pued
e us
ar u
n so
lo lu
gar d
e le
vant
ar p
ara
paqu
etes
de
trus
ses
hast
a 45
pie
s.
El c
ontra
tista
tien
e la
resp
onsa
bilid
ad d
e
reci
bir,
desc
arga
r y a
lmac
enar
ade
cuad
a-
men
te lo
s tr
usse
s en
la o
bra.
ELR
ESTR
ICCI
ÓN
/AR
RIO
STR
EEN
TOD
OS
PLAN
OS
DE
TRU
SSES
.Re
fer t
o BC
SI-B
2 Su
mm
ary
Shee
t – T
russ
Inst
alla
tion
& Te
mpo
rary
Res
train
t/Br
acin
g fo
r mor
e
info
rmat
ion.
Vea
el re
súm
en B
CSI-
B2 -
Inst
alac
ión
de T
russ
es y
Arr
iost
re T
empo
ral p
ara
may
or
info
rmac
ión.
FRAME OPENING FOR A SKYLIGHT OR CHIMNEY ABERTURA DEL ARMAZÓN PARA UN TRAGALUZ O CHIMENEA
DIMENSION NOTATIONS ARE FEET-INCHES-16THS
ANOTACIONES DE LAS DIMENSIONES SON EN PIES-PULGADAS-16 AvOS DE
PULGADA.
SETBACK OF GIRDER FROM END WALL DISTANCIA DEL
TRAvESAñO DESDE LA PARED DE EXTREMO
HANGER CONNECTIONS CONEXIONES DE COLGADORES SOPORTANTES
THE TRuSS DESIGNER PREPARES A TRuSS DESIGN DRAWING FOR EACH TRuSS. THE TRuSS DESIGN DRAWING IS A WRITTEN, GRAPHICAL AND PICTORIAL DEPICTION OF THE GEOMETRY, MATERIALS AND LOAD CONDITIONS FOR EACH INDIvIDuAL TRuSS (SEE ExAMPLE ON REvERSE).
EL DISEñADOR DE TRUSSES PREPARA UN DIBUjO DEL DISEñO DE TRUSS PARA CADA TRUSS. EL DIBUjO DE DISEñO DE TRUSS ES UNA REPRESENTACIÓN ESCRITA, GRÁFICA E ILUSTRADA DE LA GEOMETRÍA, LOS MATERIALES Y LAS CONDICIONES DE CARGAS PARA CADA TRUSS INDIvIDUAL.
vALLEY SET FRAMES OvER STRuCTuRAL FRAMING “vALLEYS” SUPERIMPUESTOS SOBRE EL ARMAZÓN ESTRUCTURAL
OPTIONAL INFORMATION INFORMACIÓN OPCIONAL
TRuSS PLACEMENT DIAGRAMS ARE OFTEN PRINTED ON THE BACK OF A
BCSI-B1 AND/OR B3 SuMMARY SHEET. LOS DIAGRAMAS DE INSTALACIÓN DE
TRUSSES CON FRECUENCIA ESTÁN IMPRESOS EN LA PARTE DE ATRÁS DE LA
HOjA DE RESUMEN BCSI-B1 Y/O B3.
ARE TRuSS PLACEMENT DIAGRAMS ENGINEERING DOCuMENTS?¿LOS DIAGRAMAS DE INSTALACIÓN DE TRUSSES SON DOCUMENTOS DE INGENIERÍA?
No, the Truss Placement Diagram prepared by the Truss Manufacturer is not an engineering document and should never be considered a replacement for a structural framing plan prepared by the Building Designer. The preparation of the Truss Placement Diagram does not require the special education, training and experience that define the practice of engineering (as found in state engineering laws).
No, el Diagrama de Instalación de Trusses preparado por el Fabricante de Trusses no es un documento de ingeniería y nunca debe ser considerado como sustituto de un plano de armazones estructurales preparado por el Diseñador del Edificio. La preparación del Diagrama de Instalación de Trusses no necesita la enseñanza especial, ni el entrenamiento ni la experiencia que definen la ejercitación de la ingeniería (tal y como aparece en las leyes estatales de ingeniería).
Copyright © 2002-2007 WTCA – Representing the Structural Building Components Industry. All Rights Reserved. Reproduction of this document, in any form, is prohibited without written permission from WTCA. This document should appear in more than one color.
Truss Technology in Building An informational series designed to address
the issues and questions faced by professionals in the building construction process.
• The truss ID that correlates to the Truss Placement Diagram or the Construction Documents.
• The number of plies required for each truss and the truss-to-truss connection requirements. • The slope or depth, span and spacing, and location of all joints and support locations. • Required bearing widths. • Design loads as applicable. • Each reaction force and direction. • Required Permanent Individual Truss Member Restraint locations and/or spacing. • La identificación del truss que corresponde con el Diagrama de Instalación
de Trusses o los Documentos de Construcción. • El número de capas necesarias para cada truss y los requisitos de la conexión de truss-a-truss. • El ángulo de inclinación o la altura, el tramo y el espaciamiento, y la ubicación de todas las junturas y soportes.. • El ancho de los soportes requeridos. • Cargas de diseño según sea aplicable. • Cada fuerza de reacción y dirección. • Ubicaciones y/o espaciamiento de Restricción Permanente Requerido de Miembros de Trusses Individuales.
EACH TRuSS DESIGN DRAWING WILL INCLuDE THE FOLLOWING INFORMATION.CADA DIBUjO DEL DISEñO DE TRUSS INCLUIRÁ LA SIGUIENTE INFORMACIÓN.
SHOuLD A TRuSS PLACEMENT DIAGRAM BE SEALED WITH AN ENGINEER’S SEAL?¿UN DIAGRAMA DE INSTALACIÓN DE TRUSSES DEBE ESTAR SELLADO CON UN SELLO DEL INGENIERO?
No, since the Truss Placement Diagram prepared by the Truss Manufacturer is not an engineering document, it should not be sealed. When a sealed structural framing plan is required, it should be prepared by the Building Designer responsible for the overall building design to ensure the adequacy and safety of the entire structure. The Truss Placement Diagram prepared by the Truss Manufacturer should ordinarily be reviewed and accepted for conformance with the overall building design by the Building Designer of Record.
No, como el Diagrama de Instalación de Trusses preparado por el Fabricante de Trusses no es un documento de ingeniería, no debe estar sellado. Cuando se necesita un plano de armazones estructurales sellado, éste debe ser preparado por el Diseñador del Edificio responsable del diseño general del mismo, para asegurar así lo necesario para la seguridad de toda la estructura. Normalmente el Diagrama de Instalación de Trusses preparado por el Fabricante de Trusses debe ser revisado y aceptado por el Diseñador del Edificio Principal para su conformidad con el diseño general del mismo.
IRC2006IRC2006
1995
3.95”4.34”
This girder is designed to carry 2ft framing TC/BC split from one side and 22ft framing to bottom chord from opposite side.
Fasten with 10d nails (0.128”x3.0”) in staggered pattern: TC, WB at 9” oc, BC at 4” oc. Repeat nailing as each ply is added.
RESTRAINT AND BRACINGRESTRAINT AND BRACING
CLR with diagonal
CLR
1) Refer to BCSI-B1 and BCSI-B2 for handling, installing, restraining and bracing guidelines.
bracing
ExAMPLE OF A TRuSS DESIGN DRAWINGEjEMPLO DE UN DIBUjO DEL DISEñO DE TRUSSES
For more information see WTCA’s TTB How to Read a Truss Design Drawing.Para más información, vea la TTB de WTCA: “Como Leer un Dibujo del Diseño de Trusses."
WTCA – Representing the Structural Building Components Industry
6300 Enterprise Lane • Madison, WI 53719608/274-4849 • 608/274-3329 fax
www.sbcindustry.com • [email protected]
To view a non-printing PDF of this document, visit www.sbcindustry.com/ttbplace.
Disclaimer
This copyrighted document is a secure PDF, and while it can be opened, saved and emailed, it cannot be printed. To order copies or receive a complimentary hard copy,