Upload
dangdieu
View
317
Download
3
Embed Size (px)
Citation preview
1
CLICKCLICKCLICK
Appearance Light emitter Output mode* Remote tuning
Red LED N-MOS FET Open drain output
P-MOS FET Open drain output
Catalog listing
NoYesNoYes
HPX-NT1HPX-NT3HPX-NT2HPX-NT4
*N-MOS and P-MOS can be used in the same way as NPN and PNP.
Percent tuningPercent tuning allows designation of a threshold value (sensor operating point) in the 50% to 150% range, with the quantity of incoming light during sensitivity setting (for ex., thru scan type without target) set as a reference at 100%. The percent designation can be made in increments of 1%. This tuning method enables free threshold setting that is appropriate for the light quantity of a particular application.
One-shot output function Delay function (ON or OFF delay) or one-shot pulse (one-shot ON or OFF) is an output programming option that can be used as needed to properly configure the output signal. Timing can be adjusted in 1ms steps in a range from 1 to 200ms and in 100ms steps in a range from 200ms to 1 second.
Remote tuning function Re-tuning can be done automatically by pushing a button or by a signal f rom a controller. The tuning parameters initially set manually can be executed remotely when an auto-tuning signal (pink wire) is received.
*Can greatly simplify adjustment work in the field. Since manual operation of the amplifier is not required for re-tuning when the operation process changes, the operator's work is simplified.
*Correction of light quantity decrement (LED aging) Frequent tuning is required for the detection of very small differences, as in the detection of a protruding LCD glass or quartz wafer, due to the fact that LEDs emit less light as they age. The solution is to tune remotely each time before detection in order to shift the operating point and correct the influence of light quantity decrement. In this way, long-term stable detection is possible. (Targetless tuning, [LH] or [PH], is executed remotely each time.)
Incominglight side
Shadedside
Threshold setting range(settable at every 1%)
Light intensity atsensitivity setting
Output
Large Small Medium
The one-shot output function can be used to provide a consistent output pulse where different target sizes are encountered.
HPX-NT Series
Selection of standard, high speed and long distance/high resolution by mode switchover. 3-digit digital display shows excess gain (light received over required level) or incoming light level. 4 types of sensitivity adjustment, plus 3 types of targetless tuning (without a workpiece): 2-step, position, maximum sensitivity, and full-auto tuning; plus (BGS, reference, and percent tuning). One-shot output (the same output timing can be set despite different target sizes).
High PerformanceFast 120µs response, 1,400mm long-distance scanning with standard fiber unit and high resolution (max. 1/80 million) all available in one amplifier by switching modes.
AMPLIFIER UNIT ORDER GUIDE
MAJOR FUNCTIONS
2
HPX-NT1, HPX-NT3Catalog listing HPX-NT2, HPX-NT4Power supply
Power consumption
Target object
Standard target object
Hysteresis
Operation mode
Output mode
Control output
Response time
Timer
Light emitter
Indicating function
Ambient light immunity
Operating temperature
Storage temperature
Ambient humidity
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Weight
Circuit protection
N-MOS FET open drain output P-MOS FET open drain output
Standard
Ultra long distance
High-speed response
Delay
One-shot
*Operating temperature range depends on the number of gang-mounted units. 1 to 2 units: -20 to +55˚C. 3 units: -20 to +50˚C. 4 to 5 units: -20 to +45˚C. 6 units: -20 to +40˚C. Do not use gang-mounting if the operating temperature exceeds the above-listed temperatures.
12 to 24Vdc ± 10% (ripple 10% peak-to-peak max.)
750mW max. (current consumption 30mA at power supply voltage 24Vdc)
Non-transparent object of more than 1mm dia. (when used with the HPF-T003)
White paper (used with the HPF-D002)
20% max. (at rated scanning distance)
Light ON/dark ON changeover (set by L-ON/D-ON changeover switch)
Switching current: 100mA max. (resistive load).Output dielectric strength: 26.4V. Voltage drop: 2V max. (at 100mA switching current).
Power short-circuit protection circuit.
1ms max. for both operation and recovery
5ms max. for both operation and recovery
120µs max. for both operation and recovery
Adjustable ON/OFF delay (1ms to 1s: 1ms to 200ms in 1ms steps, 200ms to 1s in 100ms steps)
Adjustable one-shot / OFF timer (1ms to 1s: 1ms to 200ms in 1ms steps, 200ms to 1s in 100ms steps)
Red LED
IIncoming light level, setting status, operation indicator, mode indicator (RUN, SET, TMR and ADJ)
Incandescent lamp: 3,000 lux max. Sunlight: 10,000 lux max.
-20 to +55˚C*-40 to +70˚C
35 to 85% RH (no condensation allowed)
20MΩmin. (at 500Vdc)
1,000Vac 50/60Hz for one minute between electrically live metal and case
10 to 55Hz, 1.5mm peak-to-peak amplitude, for 2 hours each in X, Y and Z directions
500m/s2, 3 times each in X, Y and Z directions
Approx. 65g (body only with 2m cable)
Output is disabled during power-up (approx. 200ms). Output reverse connection protection circuit
AMPLIFIER UNIT SPECIFICATIONS
3
2,600
1,450
280
1,400
800
150
1,010
570
100
1,060
600
110
165
95
18
165
95
18
260
140
28
190
110
20
760
440
80
65
35
7
65
35
7
40
25
5
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
Long scanningdistance
Standard
Sleeve(flexible)
Standard diameter and
compact
Elbow
Static installation,flexible, and
standard model
Static installation,flexible, and
small diameter
Small diametersleeve
Fine diametersleeve
Standard diameter
Fine diameter
Static installation,flexible, and
side view model
Static installation,flexible,
small diameter,and flat top view model
Static installation,flexible, standard, andflat side view model
Group
Longdistance
Standard
Ultra bend -tolerant
Spacesaving
Smalldiameter
Side view
HPF-T001
HPF-T002
HPF-T003
HPF-T004
HPF-T005
HPF-T006
HPF-T045
HPF-T010
HPF-T024
HPF-T025
HPF-T026
HPF-T028
HPF-T028LF
HPF-T007
HPF-T037
HPF-T042
HPF-T015
Appearance Scanning distance (mm)Sensing type Features Cable length(cuttable) Bend radius Catalog listing
R20
R20
R10/R20
R20
R20
R15
R15
R20
R5
R1
R2
HPF-T031
R1
R1
R5
Cut to length2m
Cut to length2m
Cut to length2m
Cut to length2m
Cut to length2m
Cut to length2m
Cut to length2m
Cut to length1m
3 dia.
Lens
Lens
Core: 1.4 dia. (1)
3 dia.Core: 1 dia. (1)
Sleeve 1.2 dia.
Sleeve 1.2 dia.
3 dia.Core: 1 dia. (1)
Core: 1 dia. (1)
Core: 0.5 dia. (1)
Core: 1 dia. (1)
Core: 0.5 dia. (1)
Core: 1 dia. (1)
Front view Side view
Sleeve 1 dia.
Sleeve 0.88 dia.
Sleeve 1 dia.
Core: 0.25 dia. (1)
3 11
Core: 1.4 dia. (1) M4
Core: 1 dia. (1) M4
Core: 1 dia. (1) M4
Core: 1 dia. (1) M3
M4
M3
3 11
315
10 101565 ± 4
10 10
1565 ± 4
3 11 5
515
11
Sleeve 1 dia. 2.5 dia.
2.5 dia.
2.5 dia.
3 dia.
M4
10
10
3 dia.
155 ± 2
153
113 ± 0.3
Core: 1 dia. (1) 3 dia.
1215 ± 3
1215 ± 3
1515
8
13.5
9.5
10
1.75 light axis center
2-M
3
5
103.315
35
Lens
Lens
Thru scanFIBER UNIT AND SENSING TYPE COMBINATIONS
4
4,800
2,700
520
5,300
3,000
570
4,200
2,400
450
20
12
2
20
12
2
40
25
5
40
25
5
350
200
35
780
450
80
210
120
22
820
460
85
1,400
800
150
1,000
600
100
770
440
80
720
410
75
920
520
95
500
500
110
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
Fine diameter
Small diameter
Small diameter andlong scanning distance
Fine diameter sleeve
Fine diameter sleeve
Elastic smalldiameter
HPF-T036
HPF-T038
HPF-T039
HPF-T040
HPF-T043
HPF-T044
HPF-T008
Cut to length2m
Cut to length2m
Connector0.5m
Group
Elastic
Smalldiameter
Heatresistant
Narrowbeam
Wide beam
Mapping
To 105˚C
To 150˚C
To 200˚C
Heat andcold resistant from-60˚C to +350˚C
Parallel beamtop view
Parallel beamside view
Narrow beamtop view
Narrow beam-1.5˚/+1.5˚max.
side view
Array
HPF-T009
HPF-T012
HPF-T017
HPF-T018
HPF-T014
HPF-T019
HPF-T020
HPF-T023
HPF-T021
Appearance Scanning distance (mm)Sensing type Features Bend radius Catalog listingCable length(cuttable)
R20
R15
R4
HPF-T030R5
R25
R35
R15
R25
R15
R4
Elastic standarddiameter HPF-T033
Cut to length2m
Cut to length2m
Cut to length2m
Cut to length2m
Connector1m
Connector2m
Sleeve 0.4 dia.
Sleeve 0.4 dia.
Core: 0.125 dia. (1)
Core: 0.25 dia. (1)
Core: 0.125 dia. (1)
Core: 0.25 dia. (1)
1.0 dia.
Core: 0.25 dia. (1) 3 dia.
1.5 dia.
105
M3
11
15
Core: 0.25 dia. (4)
Core: 1 dia. (1)
Core: 1.5 dia. (1)
Core:1.5 dia. (1)
Glass fiber:1 dia. (0.05 dia. x 320) (1)
Glass fiber:0.05 dia. (0.05 dia. x 370)
3 11
1 1517
153
(10)
17330
17 11
1.5 dia.
M4
M4
M4
M4
M4
4 dia.
M4
1587.5
15107.
5
10
6
6
Core: 0.25 dia. (16) M4
(Lens incorporated)
(Lens incorporated)
(Lens incorporated)
(Lens incorporated)
17 11
1.34.3
113
9 15
1560 ± 3
Core: 0.5 dia. (1) 2 dia.
Core: 0.75 dia. (1) M3
22
11
Lens
Lens
Lens
Lens
5
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
For details, contact Yamatake Corporation.
680
400
65
500
300
50
30
19
3
30
19
3
55
35
5
270
160
27
130
80
13
250
150
24
13
8
1.3
13
8
1
110
65
11
110
65
11
500
300
50
270
160
27
HPF-D006
HPF-D018
HPF-D019
HPF-D021
HPF-D039
HPF-D009
HPF-D010
R15
R15
R4
R20
HPF-D001
HPF-D002
HPF-D003
HPF-D029
HPF-D030
HPF-D031
HPF-D032
HPF-D044
HPF-D045LF
HPF-D004
HPF-D005
R20
R20
R1
R2
R5
R2
R10/R1
R1/R4
Longdistance
Standard
Ultra bend -tolerant
Compact
Coaxial
Smalldiameter
Group Appearance Scanning distance (mm)Sensing type Features Cable length(cuttable) Bend radius Catalog listing
Long scanningdistance
Small diametersleeve (bendable)
Static installation,flexible, standard, andflat side-view model
Standard
Standard
Coaxial
Coaxial
Coaxial
Small diameter
Small diametersleeve
Small diametersleeve
Fine diametersleeve
Fine diametersleeve
Small diameterlong scanning
distance
Standard diameter
Small diameter
Cut to length2m
Cut to length2m
Cut to length2m
Cut to length2m
Cut to length2m
Cut to length2m
Cut to length0.5m
Cut to length0.5m
Cut to length2m
10 10
1165 ± 4
M4
M4
M6
M3
3 dia.
3 dia.
Core: 0.5 dia. (2)
Sleeve 1.2 dia.
Sleeve 0.82 dia.
Sleeve 1.5 dia.
Sleeve 0.82 dia.
Core: 0.75 dia. (2)
Core: 0.25 dia. (2)
Core: 0.5 dia. (2)
Core: 0.25 dia. (2)
Core: 1.4 dia. (2)
Core: 1 dia. (2)
Core: 1 dia. (2)
Core: 0.5 dia. (2)
Core: 1 dia. (2)
Sleeve 1.2 dia.
Core: 0.5 dia. (2)
Core: 0.5 dia. (2)
M6
M6
M6
M3
M6
M4
Core: 0.5 dia. (emitter core dia.)(1)Core: 0.25 dia. (receiver core dia.)(4)
Core: 0.5 dia. (emitter core dia.)(1)Core: 0.25 dia. (receiver core dia.)(4)
M3
M3
Core: 0.5 dia. (2) 3 dia.
3 dia.
320
320
11
320
Core: 1 dia. (2)
Core: 1 dia. (2)
10 10
1140 ± 2
18
11
15
15 30
10
1.5 light axis center
2-M3
5
10 3.315
2.5
dia.
2065 ± 4
Lens
Lens
Core: 1 dia. (emitter core dia.)(1)Core: 0.25 dia. (receiver core dia.)(16)
15
15 ± 2 15
1015 ± 2
105 ± 2
203
18
Diffuse scan
6
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
80
45
8
95
95
15
110
65
11
50
30
5
180
120
20
310
190
30
15
15
3
25
15
3
190
190
30
500
300
50
220
130
22
160
160
27
340
200
33
2.5±0.5
90
50
9
HPF-D015
HPF-D025
HPF-D026
HPF-D028
R25
R15
R4
R15
HPF-D034
HPF-D035
HPF-D038
HPF-D042
HPF-D011
HPF-D041
HPF-D043
HPF-D012
HPF-D036
HPF-D037
HPF-D013
HPF-D022
HPF-D023
R15
R15
R20
R4
R4
R25
R35
R15
HPF-D024
Group Appearance Scanning distance (mm)Sensing type Features Bend radius Catalog listingCable length(cuttable)
Coaxial
Side view
Elastic
Heatresistant
Parallelbeam
Widebeam
Limitedreflection
Coaxial
Small diametercoaxial
Small diametersleeve
Small diametersleeve
Small diameter
To 105˚C
To 150˚C
To 200˚C
Array
Limited reflection
Sleeveheat resistant to
200˚C
Heat andcold resistant from
-60˚C to 350˚C
Parallel beamreflection
Small diametershort sleeve
Standard diameter
Standard
Cut to length2m
Cut to length2m
Cut to length2m
Cut to length2m
Cut to length2m
Cut to length2m
Cut to length2m
Cut to length2m
Cut to length2m
Connector1m
Connector1m
Connector0.5m
M6
(Built-in lens)
M5
Glass fiber: 1.5 dia.
M3
M3
M4
M6
M3
M6
M6
M6
3 dia.
3 dia.
Sleeve 2 dia.
1.5 dia.
M6
Sleeve 2 dia.
Sleeve 2.1 dia.
Core: 0.5 dia. (2)
Core: 1 dia. (2)
Core: 1.5 dia. (2)
Glass fiber: 1.4 dia.
2.8 dia.
6 dia.
15 15
35
705
19
Lens
Lens
Lens
Core: 0.25 dia. (emitter core dia.)(1)Core: 0.25 dia. (receiver core dia.)(6)
Core: 0.25 dia. (emitter core dia.)(16)Core: 0.25 dia. (receiver core dia.)(16)
Core: 0.25 dia. (emitter core dia.)(2)Core: 0.25 dia. (receiver core dia.)(2)
Core: 0.25 dia. (emitter core dia.)(2)Core: 0.25 dia. (receiver core dia.)(2)
Core: 0.5 dia. (emitter core dia.)(1)Core: 0.25 dia. (receiver core dia.)(9)
Core: 0.5 dia. (emitter core dia.)(1)Core: 0.25 dia. (receiver core dia.)(9)
Core: 0.5 dia. (emitter core dia.)(1)Core: 0.25 dia. (receiver core dia.)(9)
Glass fiber: 1.4 dia.
25173
20.5(10.7)
197 43
(4.5
)
12
10
2013
10
2015
16
40 ± 4 15
203
10
203
17133
14 102
2318
10
6
18 5
15
22
7
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
HP
nL
HS
220
130
22
35
35
—
5,250
3,000
600
1,200
690
130
420
240
—Heat resistant to
350˚C.Elbow connection
Heat resistant to350˚C.
Straight connection
Heat resistant to200˚C.
Light connector
Air side
HPF-VT07
HPF-VD07
HPF-VD09
HPF-VA01
HPF-VJ03
R25
R20
HPF-T029
HPF-T035
HPF-D014
HPF-T032
HPF-T034
HPF-D027
HPF-D033
HPF-D040
R20
R20
R25/R80
R25/R40
R4
R15/R30
Group Appearance Scanning distance (mm)Sensing type Features Cable length(cuttable) Bend radius Catalog listing
Group Appearance Scanning distance (mm)Sensing type Features Cable length(cuttable) Bend radius Catalog listing
Oil andchemical-
proof
Liquid level
Liquid leak
Thruscan
Diffusescan
PFA tubesmall diameter
Contact type.PFA tube 6mm dia.
Contact type.PFA tube 4mm dia.
Contact type
PFA tube
Pipe-mounted.Light received when
liquid present.3 to 13mm dia. pipes.
Pipe-mounted.Light received when
liquid absent.8 to 19mm dia. pipes.
Cut to length2m
Cut to length2m
Cut to length2m
Cut to length5m
Cut to length5m
Connector1m
M4
M6
M6
10102
22(8)8
6.8 2.5
7
35
320
35
3 20
Glass fiber: 1.2 bundle dia. (1)
Core: 1 dia.
4.7 dia.
(Built-in lens)
4.7 dia.
6 dia.
6 dia.
4 dia.
16
Core:3 dia. (effective lens dia.)(1)
Core: 1 dia. (2)
Lens
Glass fiber: 1.7 bundle dia.
Glass fiber: 1.7 bundle dia.
30
3 20
13.75
28
28
(60)(Bending not allowed)20
15
(40)(Bending not allowed)
14.8
5
24
430.9
20
13
Wet process
Vacuum
8
HPF-T014 + side-view unit FE-PA-S1 HPF-T024
HPF-T014 HPF-T014 + long-distance lens FE-PA-L1HPF-T017
HPF-T003,T004 + side-view unit FE-PA-S1 HPF-T008,T009 HPF-T012
HPF-T003,T004,T005,T006 HPF-T003,T004 + long-distance lens FE-PA-L1
: Standard mode : Long-distance mode : High-speed mode
HPF-T001,T002
Excess gain (light received over required level)(typical)
CHARACTERISTICS DIAGRAMS
Scanning distance (mm)
Exc
ess
gain
fact
or (t
imes
)
Scanning distance (mm)
Exc
ess
gain
fact
or (t
imes
)
Scanning distance (mm)
Exc
ess
gain
fact
or (t
imes
)
Scanning distance (mm)
Exc
ess
gain
fact
or (t
imes
)
Scanning distance (mm)
Exc
ess
gain
fact
or (t
imes
)
Scanning distance (mm)
Exc
ess
gain
fact
or (t
imes
)
Scanning distance (mm)
Exc
ess
gain
fact
or (t
imes
)
Scanning distance (mm)
Exc
ess
gain
fact
or (t
imes
)
Scanning distance (mm)
Exc
ess
gain
fact
or (t
imes
)
Scanning distance (mm)
Exc
ess
gain
fact
or (t
imes
)
Scanning distance (mm)
Exc
ess
gain
fact
or (t
imes
)
9
HPF-D002,D003 HPF-D004,D005,D006 HPF-D012
HPF-D023,D024HPF-D022HPF-D013
HPF-D029,D031HPF-D028 HPF-D030
HPF-D015 HPF-D021 HPF-D025
: Standard mode : Long-distance mode : High-speed mode
Scanningdistance Wafer (mirror polish)
Glass substrate
Wafer (rough polish)
White paper
Scanning distance (mm)
Exc
ess
gain
fact
or (t
imes
)
Scanning distance (mm)
Exc
ess
gain
fact
or (t
imes
)
Scanning distance (mm)
Exc
ess
gain
fact
or (t
imes
)
Scanning distance (mm)
Exc
ess
gain
fact
or (t
imes
)
Scanning distance (mm)
Exc
ess
gain
fact
or (t
imes
)
Scanning distance (mm)
Exc
ess
gain
fact
or (t
imes
)
Scanning distance (mm)
Exc
ess
gain
fact
or (t
imes
)
Scanning distance (mm)
Exc
ess
gain
fact
or (t
imes
)
Scanning distance (mm)
Exc
ess
gain
fact
or (t
imes
)
Scanning distance (mm)
Exc
ess
gain
fact
or (t
imes
)
Scanning distance (mm)
Exc
ess
gain
fact
or (t
imes
)
Scanning distance (mm)
Exc
ess
gain
fact
or (t
imes
)
HPF-T014 + side-view unit FE-PA-S1 HPF-T019 HPF-T020
HPF-T023HPF-T021 (vertical)HPF-T021 (horizontal)
HPF-T003,T004 + side-view unit FE-PA-S1 HPF-T008,T009 HPF-T012
HPF-T017 HPF-T014 HPF-T014 + long-distance lens FE-PA-L1
HPF-T001,T002 HPF-T003,T004,T005,T006HPF-T003,T004 + long-distance lens FE-PA-L1
: Standard mode : Long-distance mode : High-speed mode Parallel displacement (typical)
Scanning distance (mm)
Para
llel d
ispl
acem
ent (
mm
)
Scanning distance (mm)
Para
llel d
ispl
acem
ent (
mm
)
Scanning distance (mm)
Para
llel d
ispl
acem
ent (
mm
)
Scanning distance (mm)
Para
llel d
ispl
acem
ent (
mm
)
Scanning distance (mm)
Para
llel d
ispl
acem
ent (
mm
)
Scanning distance (mm)
Para
llel d
ispl
acem
ent (
mm
)
Scanning distance (mm)
Para
llel d
ispl
acem
ent (
mm
)
Scanning distance (mm)
Para
llel d
ispl
acem
ent (
mm
)
Scanning distance (mm)
Para
llel d
ispl
acem
ent (
mm
)
Scanning distance (mm)
Para
llel d
ispl
acem
ent (
mm
)
Scanning distance (mm)
Para
llel d
ispl
acem
ent (
mm
)
Scanning distance (mm)
Para
llel d
ispl
acem
ent (
mm
)
Scanning distance (mm)
Para
llel d
ispl
acem
ent (
mm
)
Scanning distance (mm)
Para
llel d
ispl
acem
ent (
mm
)
Scanning distance (mm)
Para
llel d
ispl
acem
ent (
mm
)
10
HPF-T026 (vertical)
HPF-T024 HPF-T025 HPF-T026 (horizontal)
HPF-D013 HPF-D022 HPF-D023,D024
HPF-D002,D003 HPF-D004,D005,D006 HPF-D012
: Standard mode : Long-distance mode : High-speed mode
Detection area (typical)
Scanning distance (mm)
Para
llel d
ispl
acem
ent (
mm
)
Scanning distance (mm)
Para
llel d
ispl
acem
ent (
mm
)
Scanning distance (mm)
Para
llel d
ispl
acem
ent (
mm
)
Scanning distance (mm)
Det
ectio
n ar
ea (m
m)
Scanning distance (mm)
Det
ectio
n ar
ea (m
m)
Scanning distance (mm)
Det
ectio
n ar
ea (m
m)
Scanning distance (mm)
Det
ectio
n ar
ea (m
m)
Scanning distance (mm)
Det
ectio
n ar
ea (m
m)
Scanning distance (mm)
Det
ectio
n ar
ea (m
m)
Scanning distance (mm)
Para
llel d
ispl
acem
ent (
mm
)
11
12
HPF-D030
HPF-D026 (horizontal) HPF-D026 (vertical) HPF-D029,D031
HPF-D015 HPF-D021 HPF-D025
: Standard mode : Long-distance mode : High-speed mode
Scanning distance (mm)
Det
ectio
n ar
ea (m
m)
Scanning distance (mm)
Det
ectio
n ar
ea (m
m)
Scanning distance (mm)
Det
ectio
n ar
ea (m
m)
Scanning distance (mm)
Det
ectio
n ar
ea (m
m)
Scanning distance (mm)
Det
ectio
n ar
ea (m
m)
Scanning distance (mm)
Det
ectio
n ar
ea (m
m)
Scanning distance (mm)
Det
ectio
n ar
ea (m
m)
13
Operation indicator (orange)
Mode indicator (green): RUN, SET, TMR, ADJ
Mode indication auxiliary lamp (green)
Digital display (red)
L-ON/D-ON selector
Fiber clamp lever Jog-dial switch (D-SW) Control panel cover
*Material Body: PC/ABS alloy resin, gray Control panel cover: PC resin, clear gray
*Cable: Oil-proof 4.2mm outer dia., 3 cores, 0.2 mm2 cross section Sheath color: gray
10
11
30
4.2
432
3.5
5.73.3 dia. Hole
2-3 dia.
60
35.212.4
21.5 16 6.8
9.2
7.6
Optical fiber Cable
Mounting bracket
Lever (position B)
Lever (position A)Control panel cover
Light receiving port
Light emitting port
The HPX-NT3 and HPX-NT4 models have the ability to redo auto-tuning upon receiving input from a remote location. (Tuning parameters input previously by manual tuning are executed by remote tuning signal input.) By connecting the pink wires, remote tuning is executed (refer to the circuit diagram).
(HPX-NT2, HPX-NT4)(HPX-NT1, HPX-NT3)
Note:For 2-step sensitivity tuning, enter the remote signal for both the presence and absence of the target. Leave at least 1 second between the first and second signals.
Note: Remote tuning input (pink wire) is available on the HPX-NT3 and HPX-NT4.
The following types of tuning can be executed remotely:2-step sensitivity tuning (2P), position tuning (1P)BGS (bH), reference sensitivity tuning (LH), percent tuning (PH)
N-MOS type P-MOS type
EXTERNAL DIMENSIONS
NAMES OF PARTS
REMOTE TUNING
OUTPUT CIRCUIT DIAGRAM
(unit: mm)
Amplifier unit
Remote tuning signal
Open or 9 to 30Vdc
0V
100ms min.
Brown
BlackOUTPUT12 to 24Vdc
100mA max.
Load
Mai
nci
rcui
t
Remote tuning INPUT
Blue
Pink
Brown
BlackOUTPUT12 to 24Vdc
100mA max.
Load
Mai
nci
rcui
t
Remote tuning INPUT
Blue
Pink
14
•Output is disabled upon power-up for approx. 200ms until the device stabilizes.
•Be careful of mutual interference when several sensors are used in close proximity. Make sure to check each sensor's individual operation before use.
•Applications involving strong vibration or shock should be avoided due to potential for misalignment of the optical axis.
•Keep dust away from the fiber unit head by putting it in a sealed case or using air purging.
•Ensure the sensor's correct operation by using a hood or changing the mounting direction i f there is considerable interference from ambient light.
•Wipe the surface of the fiber unit head with a soft cloth (dry or with a little water). Do not use a product such as benzine, acetone or paint thinner.
•Do not use where the cable is splashed continuously with water or oil, and do not immerse it in water or oil.
•The fiber unit head should be protected from oil and water.
• Do no t expose t he HPX-NT t o ke tones , ha logena ted hydrocarbons, esters, amines, acids, or alkalis.
•The cable may be detached if it is pulled with over 50N.
•Secure the optical fibers with cable ties so that no damage occurs due to excessive pulling force.
•Do not bend the part of the cable nearest to the amplifier beyond the minimum bend radius of 30mm, and avoid continuous bending stress.
•Take care not to hit or scratch the sensor (especially the detecting surface). Handle the sensor with care.
When the digital indication section alternatively shows and , the short-circuit protection function is active. Check the wiring.
If the amplifier is pushed forward firmly, the front lock lever can be released. The amplifier can then be pulled out as shown in the figure.
Note: If F1 is selected on the first amplifier unit, F2 must be selected on the other amplifier unit. The units must be set as a pair.
Mount the amplifier on the dedicated bracket (included with the amplifier) or on a DIN rail. Insert one rail of the bracket or DIN rail into part A as shown below. Push part B downwards until it clicks into place.
5 Troubleshooting
•If an extension of the cable is necessary, use at least 0.3mm2 wire no more than 100m long.
•If the wires of the photoelectric sensor are put in the same conduit with high-voltage or power lines, malfunction or damage may be caused by inductance.
•When using a commercially available switching regulator, ground the frame ground and ground terminals. Otherwise switching noise may cause incorrect operation.
•When using a load that generates an inrush current above the switching capacity (e.g., capacitive load, incandescent light), connect a current-limiting resistor between the load and the output terminal. Otherwise the output short-circuit protection may be activated.
3 Wiring
4 Handling
(1)Open the cover (for models with a cover).(2)Move the lever forwards to the release position.(3)Firmly insert the tip of each optical fiber into the holes in the amplifier.(4)Return the lever to the clamped position.(5)Close the cover.
For thin fibers, insert the fiber into the adapter until it projects 0.5 to 1mm from the far end. Then insert the adapter firmly into the hole of the amplifier.
1 Amplifier mounting method
2 Attaching the fiber unit to the body
1.1 Mounting the amplifier
1.2 Dismounting the amplifier
2.1 Inserting fiber units into the amplifier
2.2 Thin fiber procedure
5.1 Short-circuit
5.2 Mutual interference
PRECAUTIONS FOR USE
(1)(5)
(4)
(2)
(3)
If mutual interference occurs between 2 amplifier units, try the following procedure:On the first amplifier unit, go to SET mode – Detection capability selection mode and press the dial switch at least 8 seconds while - - is blinking (cancel).The display will show of ( of – F1 – F2 is displayed by rotating the dial).Set to F1 by pressing the dial switch.On the second amplifier unit, enter the same setting mode and set to F2 . This procedure can prevent mutual interference between 2 amplifier units.