HS IFLS Feature Activation Impact Report20th March, 2013

BackgroundBackground:To show the Impact of the HS IFLS Feature Activation (on 19 March 2013 @08:00 ) on Balancing the HS Users on U0106 and U1284 as of 1600H 20th March.MTN Ghana We set the Parameters at the same value on a coverage relation basis on both sites. Above is an example with U1284H1-U1284H2Parameters Settings U1284

MTN Ghana HS Users are now balanced between U0106G1 and U0106G2 after the feature activation.Average Number of HS Users U0106G1/G2

MTN Ghana There was not too much HS IFLS activity on the U0106H1/U0106H2 pair owing to the low value of HS Users on both sectors but not enough to reach the hsIflsThreshUsers. Fine tuning the latest will lead to more balancing.Average Number of HS Users U0106H1/H2

MTN Ghana HS Users are still Not balanced between U0106J1 and U0106J2 after the feature activation. However fine tuning the hsIflsThreshUsers will lead to more balancing.Average Number of HS Users U0106J1/J2

MTN Ghana HS Users are now balanced between U1284H1 and U1284H2 after the feature activation.Average Number of HS Users U1284H1/H2

MTN GhanaCSSR - U0106 No degradation on CSSR HS on U0106

MTN GhanaCSSR - U1284 No degradation on CSSR HS on U1284

MTN GhanaHS Volume U0106 No degradation on HS Volume on U0106

MTN GhanaHS Volume U1284 No degradation on HS Volume on U1284

MTN GhanaEUL Volume U0106 No degradation on EUL Volume on U0106

MTN GhanaEUL Volume U1284 No degradation on HS Volume on U1284

MTN GhanaU0106G1 The Feature is working as the HS IFLS Counters are pegging on U0106G1. The Incoming and Outgoing HS IFLS Success Rate are close to 100%

MTN GhanaU0106G1 The Feature is working as the HS IFLS Counters are pegging on U0106G2. The Incoming and Outgoing HS IFLS Success Rate are close to 100%

MTN GhanaU0106G1 The Feature is working as the HS IFLS Counters are pegging on U0106H1. There is little HS IFLS Activity due to the settings of hsIflsThreshUsers and the number of HS Users on the sector.

MTN GhanaU0106G1 The Feature is working as the HS IFLS Counters are pegging on U0106H2. There is little HS IFLS Activity due to the settings of hsIflsThreshUsers and the number of HS Users on the sector.

MTN GhanaU0106G1Batch 3 Sites Drops The Feature is working as the HS IFLS Counters are pegging on U0106J1. The Outgoing HS IFLS Success Rate is close to 100%

MTN GhanaU0106G1 The Feature is working as the HS IFLS Counters are pegging on U0106G2. The Incoming HS IFLS Success Rate is close to 100%.

MTN GhanaU0106G1 The Feature is working as the HS IFLS Counters are pegging on U1284H1. The Incoming and Outgoing HS IFLS Success Rate are close to 100%.

MTN GhanaU0106G1 The Feature is working as the HS IFLS Counters are pegging on U1284H2. The Incoming and Outgoing HS IFLS Success Rate are close to 100%.

MTN Ghana HS Users are now balanced between U0106G1/G2 and U1284H1/H2 after the feature activation. CSSR HS, HS and EUL Volume did not degraded after the feature activation on all the Cells. The Feature is working as the HS IFLS Counters are pegging on all sectors. The Incoming and Outgoing HS IFLS Success Rate are close to 100% on U0106G1/G2 and U1284H1/H2.There was not too much HS IFLS activity on the U0106H1/U0106H2 pair owing to the low value of HS Users on both sectors and not enough to reach the hsIflsThreshUsers to trigger the feature. Fine tuning the latest will lead to more balancing.There was quite some HS IFLS activity on the U0106J1/U0106J2 pair. Fine tuning the hsIflsThreshUsers parameter will lead to a more balanced HS Users on both sectors.SUMMARYMTN Ghana