HVAC Visual Guide-20120113

Embed Size (px)

Citation preview

  • 7/31/2019 HVAC Visual Guide-20120113

    1/15

    HVAC Survey: Visual Guide

    Use for reference while filling out the HVAC (heating + cooling) section of the survey

    --Please review the following suggested

    prioritization for completing the HVAC portion of

    the survey.

    Prioritization:1. Building owner, tenant, facilities manager

    2. Site visit

    3. Permit history or City documents

    Reminder:

    The HVAC survey questions need to be answered for each

    building use section in the building

    (e.g. a mixed-use building with a restaurant on the first

    floor and apartments on floors 2-3 would have 2 use

    sections: restaurant + apartments).

  • 7/31/2019 HVAC Visual Guide-20120113

    2/15

    Hot Water or Steam Radiator

    http://www.energysavers.gov/your_home/space_heating_cooling/index.cfm/mytopic=12580

    Typical location of distribution equipment: in-room

    Heating Only: A + B

    Stand-Up

    radiator

    Baseboard

    radiator

    Typical location of supply equipment: boiler room

    Steam or hot water boiler room (medium-sized system)

    http://www.energysavers.gov/your_home/space_heating_cooling/index.cfm/mytopic=12580http://www.energysavers.gov/your_home/space_heating_cooling/index.cfm/mytopic=12580
  • 7/31/2019 HVAC Visual Guide-20120113

    3/15

    http://www.energysavers.gov/your_home/space_heating_cooling/index.cfm/mytopic=12590

    Radiant heatingHeating Only: C

    Typical location of distribution equipment: in-floor or in-ceiling

    Hot water boiler room (smaller system)

    Typical location of supply equipment: basement

    http://www.energysavers.gov/your_home/space_heating_cooling/index.cfm/mytopic=12590http://www.energysavers.gov/your_home/space_heating_cooling/index.cfm/mytopic=12590
  • 7/31/2019 HVAC Visual Guide-20120113

    4/15

    Heating Only: D

    Individual fan units from a central hot water source

    Typical Location of equipment: ceiling or wall

    Types of Installation:

    1.Vertical

    2.Horizontal

    3.Ceiling installation

    4.Below-window placement

    Hot water boiler room (larger system)

    Typical location of supply equipment: basement

  • 7/31/2019 HVAC Visual Guide-20120113

    5/15

    Heating Only: E

    Ducted central system + heat pump(Electric-only heat)

    Typical Location of equipment:

    heat pump = exterior of building

    duct grilles = interior of building (wall, floor or ceiling)

    Exterior heat pump (smaller system)

    Ceiling grille for warmed air distribution

    Roof-top heat pump (larger system)

    with air-handler inside building

    Roof-top packaged system (larger system)

    with combined heat pump and air handler

  • 7/31/2019 HVAC Visual Guide-20120113

    6/15

    Heating Only: F

    Ducted central system + combustion furnace(Non-electric heat)

    Typical Location of equipment:

    Furnace = mechanical room or roof-top

    Duct grilles = interior of building (wall, floor or ceiling)

    Combustion furnace (smaller system)

    Wall heat distribution grille

    Exterior combustion furnace (larger system)

  • 7/31/2019 HVAC Visual Guide-20120113

    7/15

    Heating Only: G

    Electric space heat

    Typical Location of equipment: individual rooms

    In-wall unit

    Baseboard

    Plug-in heater

  • 7/31/2019 HVAC Visual Guide-20120113

    8/15

    Heating Only: H

    Reznor unit

    Stacked

    Combustion space heat

    Typical Location of equipment: individual rooms

  • 7/31/2019 HVAC Visual Guide-20120113

    9/15

    Heating Only: I + J

    Hot water radiators from district energy

    Typical Location of equipment: individual rooms

    Steam radiators from district energy

    Typical Location of equipment: individual rooms

    Confirm district energy system(if selected)

    The radiator willlook the same as a

    non-district energy

    system

  • 7/31/2019 HVAC Visual Guide-20120113

    10/15

    Heating + Cooling: A

    Ducted central system with heat pump: heating + cooling

    (Electric-only heating and cooling)

    Confirm cooling

    (if selected)

    Typical Location of equipment:

    heat pump = exterior of building

    duct grilles = interior of building

    (wall, floor or ceiling)

    Exterior heat pump (smaller system)

    Ceiling grille for warmed air distribution

    Roof-top heat pump (larger system)

    with air-handler inside building

    Roof-top packaged system (larger system)

    with combined heat pump and air handler

  • 7/31/2019 HVAC Visual Guide-20120113

    11/15

    Types of Installation:

    1.Vertical

    2.Horizontal

    3.Ceiling installation

    4.Below-window placement

    Heating + Cooling: B

    Ducted or unducted, zoned air handlers

    Typical Location of equipment:

    Zoned air handlers = individual rooms

    Confirm cooling

    (if selected)

    Ducted terminal end unit

    (fan coil)

    Unducted terminal end unit

    (fan coil)

  • 7/31/2019 HVAC Visual Guide-20120113

    12/15

    Exterior a/c unitInterior combustion furnace for heating

    Heating + Cooling: C

    Ducted central system + combustion furnace + exterior a/c

    Typical Location of equipment: furnace = basement a/c = exterior Confirm cooling +

    non-electric heat

    (if selected)Exterior combustion furnace forheating (larger system)

    Exterior roof-top heat pump

    (larger system) a/c only

    Refrigerant line

    connected to

    furnace from

    exterior a/c unit

    l

  • 7/31/2019 HVAC Visual Guide-20120113

    13/15

    Interior combustion furnace forheating (smaller system)

    Heating + Cooling: D

    Roof-top gas furnace with integrated chiller

    Ducted central system + combustion furnace + cooling tower/chiller

    Typical Location of equipment:

    furnace = basement or roof-top

    chiller tower/plant = rooftop &

    exterior

    Exterior combustion furnace for

    heating (larger system)

    Confirm cooling plus

    non-electric heat

    (if selected)

    Cooling tower for chilled water

    Cold water

    connected to

    furnace from

    exterior cooling

    tower/chiller

    H i C li E

  • 7/31/2019 HVAC Visual Guide-20120113

    14/15

    Heating + Cooling: E

    Individual through-wall electric heat pump

    Typical Location of equipment: individual rooms

    Confirm cooling

    (if selected)

    H ti C li F

  • 7/31/2019 HVAC Visual Guide-20120113

    15/15

    Heating + Cooling: F

    Exterior heat exchanger Interior fan unit

    Individual fan units in occupied space + exterior heat exchange

    Typical Location of equipment: fan unit = interior heat exchanger = exterior

    Confirm cooling