HY-OPTIMA TM 2700 Explosion Proof In-line Hydrogen Process Analyzer HY-OPTIMA TM is a registered Trademark of H2scan 27215 Turnberry Lane, Unit A, Valencia CA., 91355 Specifications subject to change without prior notice Tel: 661-775-9575, Fax: 661-775-9515 90000057 R2 Email: [email protected] , Website: www.h2scan.com Description H2scan’s HY-OPTIMA TM 2700 real time hydrogen-specific process analyzers are designed for ease of use, interface flexibility and true process control. The HY-OPTIMA TM 2700 uses a solid-state sensor that is configured to operate in process gas streams. The HY-OPTIMA TM 2700 is ideal for hydrogen production and petrochemical applications where real-time measurements can enhance process plant efficiencies, diagnostics and maintenance management. Operating Conditions Operating Humidity: 0% to 95% RH (non-condensing) Flow Rate: 0.1 slpm to 50 slpm Pressure: 0 to 7 bar gauge, 0 to 100 psi gauge Process Gas Temperature Range: -20ºC to 110ºC Operating Temperature Range: -20ºC to 55ºC Storage Temperature Range: -30ºC to 80ºC Calibration Background Gas: Nitrogen Adapter Fittings ¾” Union Tee Compression Dimensions Width: 13.8 cm (5.4 in) Length: 19.2 cm (7.5) Depth: 13.0 cm (5.7 in) Performance Hydrogen Sensitivity Range: 0.5% to 100% hydrogen by volume at 1 ATM Response Time: T90 < 30 sec Ingress Protection: IP64 capable Recommended Verification Interval: 90 days Product Life Expectancy: 10 years Accuracy(*): ± 0.3% absolute for 0.5 to 10% H 2 ± 1.0% absolute for 10 to 100% H 2 Drift/week: ± 0.2% absolute for 0.5 to 10% H 2 ± 0.4% absolute for 10 to 100% H 2 Repeatability: ± 0.2% absolute for 0.5 to 10% H 2 ± 0.4% absolute for 10 to 100% H 2 Linearity: ± 0.2% absolute for 0.5-10% H 2 ± 0.4% absolute for 10-100% H 2 Interface Options Input Voltage Range: 90 VAC to 240 VAC Input Power: 15W Analog Outputs: Output Currents 4 mA to 20 mA 0 mA to 20 mA User-specific mA range Serial Communication Options: RS232 or RS422 Relay Contacts: 5A/240VAC Two programmable relays and one fault relay with both normally open (N.O.) and normally closed (N.C.) contacts: 5A/ 30 VDC Certifications: UL 1203 UL 508 USC – Class I, Division 1, Groups B, C, and D Hazardous (Classified) Sensor performance specifications are only valid for units configured for a maximum 65ºC dry process stream and at 25 ºC ambient temperature. All figures assume pressure compensation, operating in ambient that do not contain Oxygen and are in addition to any errors in the gasses used. The accuracy is specified for serial port output only. For Latest Revision go to www.h2scan.com

HY -OPTIMA TM 2700 Explosion Proof In line Hydrogen ... · hydrogen production and petrochemical applications where real-time measurements of hydrogen can increase process plant efficiencies,

Embed Size (px)

Citation preview

Page 1: HY -OPTIMA TM 2700 Explosion Proof In line Hydrogen ... · hydrogen production and petrochemical applications where real-time measurements of hydrogen can increase process plant efficiencies,

HY-OPTIMATM 2700 Explosion Proof In-line Hydrogen Process Analyzer

HY-OPTIMATM is a registered Trademark of H2scan 27215 Turnberry Lane, Unit A, Valencia CA., 91355 Specifications subject to change without prior notice Tel: 661-775-9575, Fax: 661-775-9515 90000057 R2 Email: [email protected], Website: www.h2scan.com

Description H2scan’s HY-OPTIMATM 2700 real time hydrogen-specific process analyzers are designed for ease of use, interface flexibility and true process control. The HY-OPTIMATM 2700 uses a solid-state sensor that is configured to operate in process gas streams. The HY-OPTIMATM 2700 is ideal for hydrogen production and petrochemical applications where real-time measurements can enhance process plant efficiencies, diagnostics and maintenance management.

Operating Conditions Operating Humidity: 0% to 95% RH (non-condensing) Flow Rate: 0.1 slpm to 50 slpm Pressure: 0 to 7 bar gauge, 0 to 100 psi gauge Process Gas Temperature Range: -20ºC to 110ºC Operating Temperature Range: -20ºC to 55ºC Storage Temperature Range: -30ºC to 80ºC Calibration Background Gas: Nitrogen Adapter Fittings ¾” Union Tee Compression Dimensions Width: 13.8 cm (5.4 in) Length: 19.2 cm (7.5) Depth: 13.0 cm (5.7 in)

Performance Hydrogen Sensitivity Range:

0.5% to 100% hydrogen by volume at 1 ATM Response Time: T90 < 30 sec Ingress Protection: IP64 capable Recommended Verification Interval: 90 days Product Life Expectancy: 10 years Accuracy(*): ± 0.3% absolute for 0.5 to 10% H2 ± 1.0% absolute for 10 to 100% H2 Drift/week: ± 0.2% absolute for 0.5 to 10% H2 ± 0.4% absolute for 10 to 100% H2 Repeatability: ± 0.2% absolute for 0.5 to 10% H2 ± 0.4% absolute for 10 to 100% H2 Linearity: ± 0.2% absolute for 0.5-10% H2 ± 0.4% absolute for 10-100% H2 Interface Options Input Voltage Range: 90 VAC to 240 VAC Input Power: 15W Analog Outputs:

Output Currents • 4 mA to 20 mA • 0 mA to 20 mA • User-specific mA range

Serial Communication Options: RS232 or RS422 Relay Contacts:

• 5A/240VAC

Two programmable relays and one fault relay with both normally open (N.O.) and normally closed (N.C.) contacts:

• 5A/ 30 VDC Certifications: UL 1203 UL 508 USC – Class I, Division 1, Groups B, C, and D Hazardous (Classified) ∗ Sensor performance specifications are only valid for units configured for a maximum 65ºC dry process stream and at 25 ºC ambient temperature. All

figures assume pressure compensation, operating in ambient that do not contain Oxygen and are in addition to any errors in the gasses used. The accuracy is specified for serial port output only.

For L

ates

t Rev

isio

n go

to w

ww

.h2s

can.

com

Page 2: HY -OPTIMA TM 2700 Explosion Proof In line Hydrogen ... · hydrogen production and petrochemical applications where real-time measurements of hydrogen can increase process plant efficiencies,

HY-OPTIMATM 2720 Explosion Proof In-line Process Hydrogen Analyzer (Air) • Calibration in an Oxygen Background

HY-OPTIMATM is a registered Trademark of H2scan 27215 Turnberry Lane, Unit A, Valencia CA., 91355 Specifications subject to change without prior notice Tel: 661-775-9575, Fax: 661-775-9515 90000062 R1 Email: [email protected], Website: www.h2scan.com

Operating Conditions Operating Humidity: 0% to 95% RH Flow Rate: 0.1 slpm to 50 slpm Pressure: 0 to 7 bar gauge, 0 to 100 psi gauge Process Gas Temperature Range: -20ºC to 65ºC Operating Temperature Range: -20ºC to 40ºC Storage Temperature Range: -30ºC to 80ºC Calibration Background Gas: Air Adapter Fittings ¾” Union Tee Compression Dimensions Width: 13.8 cm (5.4 in) Length: 19.2 cm (7.5) Depth: 13.0 cm (5.7 in)

Description H2scan’s Series 2700 real time hydrogen-specific process analyzers are designed for ease of use, interface flexibility and true process control. The HY-OPTIMATM 2720 is a solid state sensor configured to operate in air background gas streams having up to 95% relative humidity and temperatures up to 65ºC. The HY-OPTIMATM 2720 is ideal for the monitoring of hydrogen processes where real time measurements of hydrogen can ensure safety in application, increase process efficiencies, improve diagnostics and enhance maintenance management translating into higher profitability.

Performance Hydrogen Sensitivity Range:

0.5% to 5% hydrogen by volume at 1 ATM Response Time: T90 < 60 sec Ingress Protection: IP64 capable Calibration Interval: 90 days Product Life Expectancy: 10 years Accuracy: ± 3% of reading + 2000 ppm

Interface Options Input Voltage Range: 90 VAC to 240 VAC Input Power: 15W Analog Outputs:

Output Currents • 4 mA to 20 mA • 0 mA to 20 mA • User-specific mA range

Serial Communication Options: RS232 or RS422 Relay Contacts:

• 5A/240VAC

Two programmable relays and one fault relay with both normally open (N.O.) and normally closed (N.C.) contacts:

• 5A/ 30 VDC Certifications: UL 1203 UL 508 USC – Class I, Division 1, Groups B, C and D Hazardous (Classified)

∗ Sensor performance specifications are only valid for units configured for a maximum 65ºC dry process stream and at 25 ºC ambient temperature. All figures assume pressure compensation and are in addition to any errors in the gasses used. The accuracy is specified for serial port and digital display output only.

For L

ates

t Rev

isio

n go

to w

ww

.h2s

can.

com

Page 3: HY -OPTIMA TM 2700 Explosion Proof In line Hydrogen ... · hydrogen production and petrochemical applications where real-time measurements of hydrogen can increase process plant efficiencies,

HY-OPTIMATM 2730 Explosion Proof Process Hydrogen Analyzer (ppm H2S & CO) • CO and H2S Tolerance

HY-OPTIMATM is a registered Trademark of H2scan 27215 Turnberry Lane, Unit A, Valencia CA., 91355 Specifications subject to change without prior notice Tel: 661-775-9575, Fax: 661-775-9515 90000063 R1 Email: [email protected], Website: www.h2scan.com

Description H2scan’s Series 2700 real-time hydrogen specific process analyzers are designed for ease of use, interface flexibility and true process control. The HY-OPTIMATM 2730 is a solid-state sensor configured to operate in background gas streams having carbon monoxide concentrations up to 100 ppm, hydrogen sulfide concentrations up to 1000 ppm, up to 95% relative humidity, and gas temperatures up to 110ºC. The HY-OPTIMATM 2730 is ideal for hydrogen production and petrochemical applications where real-time measurements of hydrogen can increase process plant efficiencies, improve diagnostics and enhance maintenance management translating into higher profitability.

Operating Conditions Process Gas Tolerance: CO tolerance: 100 ppm H2S tolerance: 1000 ppm Operating Humidity: 0% to 95% RH Flow Rate: 0.1 slpm to 50 slpm Pressure: 0 to 7 bar gauge, 0 to 100 psi gauge Process Gas Temperature Range: -20ºC to 110ºC Operating Temperature Range: -20ºC to 55ºC Storage Temperature Range: -30ºC to 80ºC Calibration Background Gas: Nitrogen Adapter Fittings ¾” Union Tee Compression Dimensions Width: 13.8 cm (5.4 in) Length: 19.2 cm (7.5) Depth: 13.0 cm (5.7 in) Certifications: UL 1203 UL 508 USC – Class I, Division 1, Groups B, C and D Hazardous (Classified)

Performance Hydrogen Sensitivity Range:

0.5% to 100% hydrogen at 1 ATM on a volume basis in a single or multi-component gas background

Response Time: T90 < 30 sec Ingress Protection: IP64 capable Recommended Verification Interval: 90 days Product Life Expectancy: 10 years Accuracy(*): ± 0.15% absolute for 0.5 to 10% H2 ± 0.5% absolute for 10 to 100% H2 Drift/week: ± 0.2% absolute for 0.5 to 10% H2 ± 0.4% absolute for 10 to 100% H2 Repeatability: ± 0.2% absolute for 0.5 to 10% H2 ± 0.4% absolute for 10 to 100% H2 Linearity: ± 0.2% absolute for 0.5-10% H2 ± 0.4% absolute for 10-100% H2 Interface Options Input Voltage Range: 90 VAC to 240 VAC Input Power: 15W Analog Outputs:

Output Currents • 4 mA to 20 mA • 0 mA to 20 mA • User-specific mA range

Serial Communication Options: RS232 or RS422 Relay Contacts:

• 5A/240VAC

Two programmable relays and one fault relay with both normally open (N.O.) and normally closed (N.C.) contacts:

• 5A/ 30 VDC ∗ Sensor performance specifications are only valid for units configured for a maximum 65ºC dry process stream and at 25 ºC ambient temperature. All figures assume pressure compensation and are in addition to any errors in the gasses used. The accuracy is specified for serial port and digital display output only.

For L

ates

t Rev

isio

n go

to w

ww

.h2s

can.

com

Page 4: HY -OPTIMA TM 2700 Explosion Proof In line Hydrogen ... · hydrogen production and petrochemical applications where real-time measurements of hydrogen can increase process plant efficiencies,

HY-OPTIMATM 2740 Explosion Proof In-line Area Hydrogen Analyzer (% H2S & CO) • % Level CO and % Level H2S Tolerance

HY-OPTIMATM is a registered Trademark of H2scan 27215 Turnberry Lane, Unit A, Valencia CA., 91355 Specifications subject to change without prior notice Tel: 661-775-9575, Fax: 661-775-9515 90000064 R1 Email: [email protected], Website: www.h2scan.com

Description H2scan’s Series 2700 real-time hydrogen specific process analyzers are designed for ease of use, interface flexibility and true process control. The HY-OPTIMATM 2740 is a solid-state sensor configured to operate in background gas streams having carbon monoxide, concentrations up to 20% by volume, hydrogen sulfide concentrations up to 10% by volume, up to 95% relative humidity, and temperatures up to 110ºC. The HY-OPTIMATM 2740 is ideal for hydrogen production and petrochemical applications where real-time measurements of hydrogen can increase process plant efficiencies, improve diagnostics and enhance maintenance management translating into higher profitability.

Operating Conditions Process Gas Tolerance: CO tolerance: 20% by volume H2S tolerance: 10% by volume Operating Humidity: 0% to 95% RH (non condensing) Flow Rate: 0.1 slpm to 50 slpm Pressure: 0 to 7 bar gauge, 0 to 100 psi gauge Process Gas Temperature Range: -20ºC to 110ºC Operating Temperature Range: -20ºC to 55ºC Storage Temperature Range: -30ºC to 80ºC Calibration Background Gas: Nitrogen Adapter Fittings ¾” Union Tee Compression Dimensions Width: 13.8 cm (5.4 in) Length: 19.2 cm (7.5) Depth: 13.0 cm (5.7 in)

Performance Hydrogen Sensitivity Range:

0.5% to 100% hydrogen at 1 ATM on a volume basis in a single or multi-component gas background

Response Time: T90 < 60 sec Ingress Protection: IP64 capable Recommended Verification Interval: 90 days Product Life Expectancy: 10 years Accuracy(*): ± 0.3% absolute for 0.5 to 10% H2 ± 1.0% absolute for 10 to 100% H2 Drift/week: ± 0.2% absolute for 0.5 to 10% H2 ± 0.4% absolute for 10 to 100% H2 Repeatability: ± 0.2% absolute for 0.5 to 10% H2 ± 0.4% absolute for 10 to 100% H2 Linearity: ± 0.2% absolute for 0.5-10% H2 ± 0.4% absolute for 10-100% H2 Interface Options Input Voltage Range: 90 VAC to 240 VAC Input Power: 15W Analog Outputs:

Output Currents • 4 mA to 20 mA • 0 mA to 20 mA • User-specific mA range

RS232 or RS422 Serial Communication Options:

Relay Contacts:relays and one fault relay with both

Two programmable

normally open (N.O.) and normally closed (N.C.) contacts:

• 5A/240VAC • 5A/ 30 VDC

Certifications: UL 1203 UL 508 USC – Class I, Division 1, Groups B, C, and D Hazardous (Classified) ∗ Sensor performance specifications are only valid for units configured for a maximum 65ºC dry process stream and at 25ºC ambient temperature. All figures assume pressure compensation, operating in ambient that do not contain Oxygen and are in addition to any errors in the gasses used. The accuracy is specified for serial port and digital display output only.