    WITH MULTIFLEXIBLE CONFIGURATION FOR ROBUST AND EFFICIENT HEAT TRANSFERAPV Hybrid - Welded Heat Exchanger

    APV H EAT EXC HANG E R S

  • 8/22/2019 Hybrid_1208_03_02_2012_GB

    2/8

    1208-03-02-2012-GB

    WHAT COULD HAPPEN IFYOU COMPROMISE HERE?

    WHAT CAN YOU EXPECTFROM SPX AND HYBRID?

    V E R Y H IGH W OR K I NGTEMPERATURE, INCLUDINGT E MP E R A T UR E S HOCK S

    E QUIP ME NT F A ILUR E / R E P LA CE ME NT

    LONGE R P R OD UCT IONUP T IME

    V E R Y H IGH W OR K I NGP R E S S UR E INCLUDINGP R E S S UR E S HOCK S

    E QUIP ME NT F A ILUR E / R E P LA CE ME NT

    LONGE R P R OD UCT IONUP T IME

    S MA LL F OOT P R INTHIGH CONV E R S ION/

    E N G I N E E R I N G C O S TSCOST SAVINGS,A CCE S S IB IL IT Y

    HIGH HEAT RECOVERY,EXTREME SMALL LOGMEAN TEMPERATURED I F F E R E N C E

    H I G H E R R U N N I N G C O S T SCOST SAVINGS, LOWER

    CO2 F OOT P R INT

    CLEANABIL ITY , MANUALA ND C IP

    R E DUCE D E F F IC IE NCYOPERATION AT DESIREDSPECIF ICATION AFTER

    CLE A NING

    RESI STANCE TOC O R R O S I O N

    E QUIP ME NT F A ILUR E / R E P LA CE ME NT

    LONG S E R V ICE L IF E

    Choosing the right Heat Exchanger canbe a complex matter

    HOW CAN ONE SI NGLE H EAT EXCHANGER TECH NOLOGY

    COVER ALL YOUR KEY PRIORITIES?

    In a complex decision process, neglecting key priorities may lead to low perfor-mance or even plant failure things you would re-do if you could.

    With more than a century of heat exchanger experience, SPX knows the needsand priorities of most industries.

    Let SPX guide you through complex choices to the right solution for yourspecific application and needs.

    IF THESE ARE SOME OF YOUR PRIORIT IES

    HYBRID I S FOR YOU!

    Based on a multi-flexible configuration platform, Hybrid is designed to operate

    under harsh conditions where other heat exchanger technologies can fail, have a

    shorter operating lifetime, or reduce operational efficiency.

    Whats more, easy access makes high-pressure cleaning of Hybrid plates simple,

    effective and fast!

    APV invented the plate heat exchanger

    in 1923 (Now SPX) and has continuously

    proven to be the preferred partner for

    heat transfer applications. By pioneering

    applicable technology in pressing, shaping,welding, sealing and testing steel, SPX has

    continued to develop and improve heat

    transfer technologies.

    The company is committed to delivering

    an efficient and durable solution to ensure

    operational excellence, effectiveness and

    profitability.

    SPX offers an extensive portfolio of plate

    heat exchanges covering many industrial

    applications. Regularly SPX heat exchangers

    replace older technology products due

    to the simplicity of installation and their

    high performance thermal characteristics.

    Whether recovering waste heat or isolating

    the cooling system from the cooling

    source, SPX has the application knowledge

    and product to improve efficiency and

    performance.

  • 8/22/2019 Hybrid_1208_03_02_2012_GB

    3/8

    31208-03-02-2012-GB

    The heart of the matterThe central plate core is contained by 4 movable pressure panels,

    and the 2 flows are separated by the plate wall and 4 corner bars.

    Pass plates: turn flow to

    support multi-pass cross flow

    Plate core: heat transfer

    plates welded together to

    separate and exchange

    heat between the 2

    media

    Panels: 6 bolted panels

    holding together the

    plate core

    Typical product applications

    Power

    Steam condenser

    District heating units

    Industrial

    Reboiler

    Chemical

    Solution cooler and heater

    Process condenser

    Cryogenic chiller

    G ENER A L USE

    350C (662F)

    32 bar (up to 40) design pressure (580 psig)

    Corrosive media

    Gas/steam/air with low pressure drop

    Pass-through of particles/solid

    Oil and Gas

    Gas sweetening

    Gas Dehydration

    Crude oil stabilizer

    Crude oil heater

  • 8/22/2019 Hybrid_1208_03_02_2012_GB

    4/8

    Hybrid 24 Hybrid 12 Hybrid 8 Hybrid 6 Hybrid 4 Hybrid 2

    H

    L

    W

    1208-03-02-2012-GB

    MOD EL 2 4 6 8 12 24

    N U M B E R OF TH E R MAL ST E P S 2 4 6 8 12 2X12

    STACK H E I G HT VE R S I ON S 5 1 1 3 5 5

    P OS S IBLE P A S S COMBINA T IONS ONP R IMA R Y S IDE CUR R UGA TE D S IDE

    3 3 3 3 3 3

    P OS S IBLE P A S S COMBINA T IONS ONS E CONDA R Y S IDE T UBULA R S IDE

    4 5 7 6 9 9

    456 STANDARD COM BINATIONS PE R PLATE MATERIAL:

    to meet all your needs

    We will always find the perfect solution

    Perfect adaptability for almost any application

    Full utilisation of pressure drop to maximise thermal efficiency

    Close temperature approach down to 1C possible (1.8F)

    Low pressure drop possible even at high mass flows even for gas/steam

    Perfect for condensation and evaporation (including vacuum condensation)

    Large connection sizes possible

    Non-symmetric flows handled, even with perfect pressure drop utilisation

    6 BASIC MODELS

    MOD E L 2 4 6 8 12 24

    H E I G HT M M I N CH 1052 41.42 1052 41 .42 1052 41.42 1052 41 .42 1052 41.42 14 84 58 .43

    LE N GTH M M I N CH 1425 5 6,10 1857 73.11 228 9 90 .12 2721 107.13 35 85 141.18 3585 141.18

    W IDT H MM INCH391787

    15.431 .9860 7

    23 .9060 7

    23 .90607787

    23.9031.987151075

    28.1542.327151075

    28.1542.32

    Design Pressure: 16 or 32 Bar (232.1 or 464.1 psig)

    Design Code: ASME VIII, Div 1 or PED

    Design Temperature: -28/-40 to 350C (-18.4/-40 to 662F)

  • 8/22/2019 Hybrid_1208_03_02_2012_GB

    5/8

    51208-03-02-2012-GB

    Unseen flexibility based on a range of standard variantsEACH AVAILABLE IN VARIOUS STANDARD CON FIGU RATIONS:

    High number of passes tube

    side system in combination

    with corrugated side sandwich

    system for close temperature

    approach applications (heat

    recovery)

    Single pass tube system in

    combination with corrugated

    side sandwich system for

    multiphase applications (e.g.

    condensation)

    Low number of passes tube

    side system in combination

    with single pass corrugated

    side system for low NTU

    value applications and/or lowpressure drop requirements

    EXAMPLE 1

    EXAMPLE 2

    EXAMPLE 3

  • 8/22/2019 Hybrid_1208_03_02_2012_GB

    6/8

    TUPLAFLOW 37

    TUPLAFLOW 28

    ENERGYSAVER

    1208-03-02-2012-GB

    HYBRID FEATURES 3 VERY DIFFERENT PLATE TYPES!

    3 plate variants depending on your needs

    If your focus is optimum efficiency and pressure droplimitations are not an issue.

    High turbulence

    Highest efficiency

    Highest pressure resistance

    If manual cleaning and/or low pressure drop are essential(e.g. steam/gas).

    Pressure drop on tube side can be kept extremely low

    Excellent for gas/steam

    Excellent mechanical cleanability combined with high heattransfer performance

    If you want the best combination in between.

    Good mechanical cleanability combined with excellentheat transfer performance

    Cross section of TuplaFlow plate types

    All plates are cross-flow

  • 8/22/2019 Hybrid_1208_03_02_2012_GB

    7/8

    71208-03-02-2012-GB

    Do fouling or scaling impact your production planning?

    Spare capacity, filter systems or CIP cleaning systems are expensive to install.

    2 of the 3 plate options can be cleaned effectively using manual high pressure cleaning.

    TuplaFlow plate packOpenable design

    Bolted Hybrid can be opened.

    The tube-side p late gap can be high-

    pressure c leaned (TuplaFlow).

    HUGE FLEXIBILITY BASED ON STANDARD VARIANTS

    Customisation Options:

    Plates in other alloys

    Fully welded vessel construction (not openable)

    Venting options

    Sub cooling

    >5000 m2heat transfer area (53819 ft2)

    M OD EL 2 4 6 8 12 24

    HEAT TRANSFER IN M2 FT 2 625 652692833

    3013554150

    4415385597

    5921044105218

    11302346210436

    22604693

    MA X . NOZ Z LE S IZ E T UBU S IDEDN4 5 0

    18 "DN3 5 0

    14 "DN3 5 0

    14 "DN5 0 0

    20 "DN5 0 0

    20 "DN5 0 0

    20 "

    MAX. NOZZLE S IZECOR R UGA T E D S IDE

    DN3 0 012 "

    DN3 0 012 "

    DN3 0 012 "

    DN3 0 012 "

    DN3 0 012 "

    DN5 0 020 "

    MATERIAL PLATESSTANDARD: 1 .4404 316LON RE QUEST: 1 .4571 316TI / 1 .4301 304 / 1 .4539 904L / 1 .4547 254SM O / 2 .4819276 / 2 .4602C22 /2 .4605C2000 / AND OTHERS

    DE S IGN T E MP E R A T UR EACCORDING TO ASME V I I I : 28C TO 350C 18 .4F TO 662FACCORD ING TO PE D 97/23 EK: 40C TO 350C 40F TO 662F

    D ES I G N P R E S S U R E 16 AN D 32 BAR VE R S I O NS , I N CLU D I N G F U LL VACCU U M.

    DE S IGN CODEPED 97/23 EG / EN 13445A S ME . V I I I , D IV . 1

    F LA NGE R A T INGSW E LDE D NE CK F LA NGE SEN 10921 / ANSI B16.5

    N OZ Z LE LOAD S AP I 6 62 TAB LE I I

  • 8/22/2019 Hybrid_1208_03_02_2012_GB

    8/8

    WITH M ULTIFLEXI BLE

    CONFIG URATION FOR

    ROBUST AND EFFICIENT

    HEAT TRANSFER

    Hybrid - WeldedHeat Exchanger

    SPX FLOW TECHNOLOGY

    Platinvej 8

    6000 Kolding, Denmark

    P: (+45) 70 278 444

    F: (+45) 70 278 445

    E: [email protected]

    SPX reserves the right to incorporate our latest design and material changes without notice or obligation.

    Design features, materials of construction and dimensional data, as described in this bulletin, are provided for your information only and should not be relied upon unless

    confirmed in writing. Please contact your local sales representative for product availability in your region. For more information visit www.spx.com.

    The green > is a trademark of SPX Corporation, Inc..

    SSUED 02/2012 1208-03-02-2012-GB

    COPYRIGHT 2010, 2012 SPX Corporation

    ABOUT S PX

    Based in Charlotte, North Carolina, SPX Corporation (NYSE: SPW) is a global Fortune 500 multi-industry manufacturing leader. For more information, please visit www.spx.com.

    SPX FLOW TECHNOLOGY

    105 CrossPoint Parkway

    Getzville, NY 14068

    USA

    P: (800) 462-6893

    F: (716) 692-1715

    E: [email protected]