Hydrodynamic Loads and their Impact on Foundation Design Harris King Senior Structural Engineer [email protected] Subsea Expo 2017

Hydrodynamic Loads and their Impact on Foundation Design · Hydrodynamic Loads and their Impact on Foundation Design Harris King – Senior Structural Engineer [email protected]

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Hydrodynamic Loads and their Impact on Foundation Design · Hydrodynamic Loads and their Impact on Foundation Design Harris King – Senior Structural Engineer Harris.King@woodgroup.com

Hydrodynamic Loads and their Impact

on Foundation Design

Harris King – Senior Structural Engineer

[email protected]

Subsea Expo 2017

Page 2: Hydrodynamic Loads and their Impact on Foundation Design · Hydrodynamic Loads and their Impact on Foundation Design Harris King – Senior Structural Engineer Harris.King@woodgroup.com

• Introduction

• The Problem

• Foundation Design

• Current Methodologies

• Refinement

• Outcome

Agenda

2

Page 3: Hydrodynamic Loads and their Impact on Foundation Design · Hydrodynamic Loads and their Impact on Foundation Design Harris King – Senior Structural Engineer Harris.King@woodgroup.com

• Inspiration came from experiences with a recent

project

• SSIV structure within 500m zone

Introduction – Past Experience

3

Page 4: Hydrodynamic Loads and their Impact on Foundation Design · Hydrodynamic Loads and their Impact on Foundation Design Harris King – Senior Structural Engineer Harris.King@woodgroup.com

• Challenging geotechnical conditions

– Close to 3 different soil formations

Introduction – Past Experience

4

2 kPa

Page 5: Hydrodynamic Loads and their Impact on Foundation Design · Hydrodynamic Loads and their Impact on Foundation Design Harris King – Senior Structural Engineer Harris.King@woodgroup.com

• Initial plan to install 2 structures in 1 campaign – no

longer feasible

Introduction – Past Experience

5

Page 6: Hydrodynamic Loads and their Impact on Foundation Design · Hydrodynamic Loads and their Impact on Foundation Design Harris King – Senior Structural Engineer Harris.King@woodgroup.com

• Obtain site specific soils info

• Generate a more complex design incorporating

retractable mudmats

• Use CFD to better quantify applied loads

Introduction – Past Experience

6

Page 7: Hydrodynamic Loads and their Impact on Foundation Design · Hydrodynamic Loads and their Impact on Foundation Design Harris King – Senior Structural Engineer Harris.King@woodgroup.com

• Gravity based subsea structures subject to

environmental loads

• Can lead to increased weight/footprint to achieve on

bottom stability

• Potential increases in fabrication and installation

complexity

• Cost saving opportunity

The Problem

7

Page 8: Hydrodynamic Loads and their Impact on Foundation Design · Hydrodynamic Loads and their Impact on Foundation Design Harris King – Senior Structural Engineer Harris.King@woodgroup.com

• Installation complexity

The Problem

8

Page 9: Hydrodynamic Loads and their Impact on Foundation Design · Hydrodynamic Loads and their Impact on Foundation Design Harris King – Senior Structural Engineer Harris.King@woodgroup.com

Background – Foundation Design

9

• Methodologies outlined in API, ISO and DNV codes

• Develop a design that avoids:

– Sliding failure (horizontal)

– Bearing failure (vertical)

Page 10: Hydrodynamic Loads and their Impact on Foundation Design · Hydrodynamic Loads and their Impact on Foundation Design Harris King – Senior Structural Engineer Harris.King@woodgroup.com

Background – Foundation Design

10

• Bearing failure (vertical)

• Eccentricity - M

Fv

Fv

M

Fv

Fh Fh

Extract from API RP 2GEO/ISO 19901-4

Page 11: Hydrodynamic Loads and their Impact on Foundation Design · Hydrodynamic Loads and their Impact on Foundation Design Harris King – Senior Structural Engineer Harris.King@woodgroup.com

Background – Foundation Design

11

• Sliding failure (horizontal)

• Increased area (clay) or increased weight (sand)

Fv

Fh

Fv

Fh

Page 12: Hydrodynamic Loads and their Impact on Foundation Design · Hydrodynamic Loads and their Impact on Foundation Design Harris King – Senior Structural Engineer Harris.King@woodgroup.com

Current Methodologies

12

• Morison’s Equation

• L = 4.46m, D = 7.46m, H = 4.05m. A = 30.2m2

• Lateral Load = 306kN @ 3.0ms-1

• Approximate 30% reduction accounting for solidity –

242 kN

Page 13: Hydrodynamic Loads and their Impact on Foundation Design · Hydrodynamic Loads and their Impact on Foundation Design Harris King – Senior Structural Engineer Harris.King@woodgroup.com

Current Methodologies

13

• Assessment within beam FE Model

• Lateral Load = 229 kN @ 3.0 ms-1

Page 14: Hydrodynamic Loads and their Impact on Foundation Design · Hydrodynamic Loads and their Impact on Foundation Design Harris King – Senior Structural Engineer Harris.King@woodgroup.com

Current Methodologies

14

• Reduced drag loads for shielded members using

guidance from DNV RP H103

• Lateral Load = ~200 kN @ 3.0 ms-1

Page 15: Hydrodynamic Loads and their Impact on Foundation Design · Hydrodynamic Loads and their Impact on Foundation Design Harris King – Senior Structural Engineer Harris.King@woodgroup.com

Current Methodologies

15

• 306 kN – Solid Body

• 242 kN – Solid Body (accounting for solidity)

• 229 kN – Assessment within beam FE Model

• 200 kN – Assessment within beam FE Model (with

shielding)

• ?

Page 16: Hydrodynamic Loads and their Impact on Foundation Design · Hydrodynamic Loads and their Impact on Foundation Design Harris King – Senior Structural Engineer Harris.King@woodgroup.com

Refinement

16

• CFD Results

Page 17: Hydrodynamic Loads and their Impact on Foundation Design · Hydrodynamic Loads and their Impact on Foundation Design Harris King – Senior Structural Engineer Harris.King@woodgroup.com

Refinement

17

• CFD Modelling of structure

• Lateral Load = 80 kN @ 3.0 ms-1

Page 18: Hydrodynamic Loads and their Impact on Foundation Design · Hydrodynamic Loads and their Impact on Foundation Design Harris King – Senior Structural Engineer Harris.King@woodgroup.com

Refinement

18

• 67% load reduction compared

to solid body (with solidity

reduction)

• 35% Reduction compared to

solid body (with solidity

reduction)

Page 19: Hydrodynamic Loads and their Impact on Foundation Design · Hydrodynamic Loads and their Impact on Foundation Design Harris King – Senior Structural Engineer Harris.King@woodgroup.com

Refinement

19

• 306 kN – Solid Body

• 242 kN – Solid Body (accounting for solidity)

• 229 kN – Assessment within beam FE Model

• 200 kN – Assessment within beam FE Model (with

shielding)

• 80 kN – CFD approach

Page 20: Hydrodynamic Loads and their Impact on Foundation Design · Hydrodynamic Loads and their Impact on Foundation Design Harris King – Senior Structural Engineer Harris.King@woodgroup.com

• Foundation capacity on Sand

– Sliding resistance generally proportional to on

bottom weight

20

Outcome – Foundation Design

Lateral Load (kN) Minimum Required on

bottom weight (t)

306 100

242 79

229 75

200 66

80 26

Page 21: Hydrodynamic Loads and their Impact on Foundation Design · Hydrodynamic Loads and their Impact on Foundation Design Harris King – Senior Structural Engineer Harris.King@woodgroup.com

Outcome – Foundation Design

21

• Foundation capacity on clay

– Generally proportional to mud mat area

10.0m

6.0m

6.0m

3.6m

Page 22: Hydrodynamic Loads and their Impact on Foundation Design · Hydrodynamic Loads and their Impact on Foundation Design Harris King – Senior Structural Engineer Harris.King@woodgroup.com

• Potential to achieve

– Lighter, smaller structure

– Reduce fabrication quantity

– Reduce deck space, crane size on installation

vessel

– Circa. £10ks vs £100ks

– Lower cost

Conclusions

22

Page 23: Hydrodynamic Loads and their Impact on Foundation Design · Hydrodynamic Loads and their Impact on Foundation Design Harris King – Senior Structural Engineer Harris.King@woodgroup.com

Questions ?

Summary

23

Page 24: Hydrodynamic Loads and their Impact on Foundation Design · Hydrodynamic Loads and their Impact on Foundation Design Harris King – Senior Structural Engineer Harris.King@woodgroup.com

Harris King – Senior Structural Engineer

[email protected]

Subsea Expo 2017