2 A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
IDU Product Description
The information in this document is subject to change without notice and describes only the
product defined in the introduction of this documentation. This documentation is intended for the
use of Nokia Siemens Networks customers only for the purposes of the agreement under whichthe document is submitted, and no part of it may be used, reproduced, modified or transmitted
in any form or means without the prior written permission of Nokia Siemens Networks. The
documentation has been prepared to be used by professional and properly trained personnel,
and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes
customer comments as part of the process of continuous development and improvement of the
documentation.
The information or statements given in this documentation concerning the suitability, capacity,
or performance of the mentioned hardware or software products are given "as is" and all liability
arising in connection with such hardware or software products shall be defined conclusively and
finally in a separate agreement between Nokia Siemens Networks and the customer. However,
Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions
contained in the document are adequate and free of material errors and omissions. Nokia
Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which
may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO
EVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THIS DOCUMEN-
TATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT,
INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT
LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS
OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR
THE INFORMATION IN IT.
This documentation and the product it describes are considered protected by copyrights and
other intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark
of Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respectiveowners, and they are mentioned for identification purposes only.
Copyright © Nokia Siemens Networks 2009. All rights reserved.
f Important Notice on Product SafetyElevated voltages are inevitably present at specific points in this electrical equipment.
Some of the parts may also have elevated operating temperatures.
Non-observance of these conditions and the safety instructions can result in personal
injury or in property damage.
Therefore, only trained and qualified personnel may install and maintain the system.
The system complies with the standard EN 60950 / IEC 60950. All equipment connected
has to comply with the applicable safety standards.
The same text in German:
Wichtiger Hinweis zur Produktsicherheit
In elektrischen Anlagen stehen zwangsläufig bestimmte Teile der Geräte unter Span-
nung. Einige Teile können auch eine hohe Betriebstemperatur aufweisen.
Eine Nichtbeachtung dieser Situation und der Warnungshinweise kann zu Körperverlet-
zungen und Sachschäden führen.
Deshalb wird vorausgesetzt, dass nur geschultes und qualifiziertes Personal die
Anlagen installiert und wartet.
Das System entspricht den Anforderungen der EN 60950 / IEC 60950. Angeschlossene
Geräte müssen die zutreffenden Sicherheitsbestimmungen erfüllen.
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 3/43
A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
3
IDU Product Description
Table of ContentsThis document has 43 pages.
1 Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71.1 Intended audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.2 Structure of this document. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.3 Symbols and conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.4 History of changes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.5 Waste electrical and electronic equipment (WEEE) . . . . . . . . . . . . . . . . 9
1.6 RoHS compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3 Functional description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3.1 Controller2 Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.2 Standard2 Master IO and Enhanced2 Master IO Modules . . . . . . . . . . 14
3.3 Enhanced GigE Master IO Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
4 Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
4.1 Payload Processing And User Interface Functionalities . . . . . . . . . . . . 16
4.1.1 E1 payload processing (Standard, Standard2, Enhanced and Enhanced2
Master I/O Unit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
4.1.2 E1 payload processing (42xE1 Master I/O Unit and 21xE1 Expansion unit)
16
4.1.3 STM1 payload processing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4.1.3.1 Multiplexing structure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4.1.3.2 SDH Performance Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224.1.4 Ethernet payload Processing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
4.1.5 NMS interface (SNMP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
4.2 Serial/Alarm management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
4.3 Voice/Order Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
5 Supported IDU Compositions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
6 External interfaces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
6.1 Power Supply Unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
6.2 Controller and Controller2 Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
6.3 Standard/Standard2 Master I/O Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
6.4 Enhanced/Enhanced2 Master I/O Unit . . . . . . . . . . . . . . . . . . . . . . . . . 346.5 16 E1 Expansion I/O unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
6.6 42xE1 Master I/O Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
6.7 21x E1 Expansion I/O unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
6.8 Gigabit Ethernet/Gigabit Enhanced Ethernet Master I/O Unit . . . . . . . . 37
6.9 STM-1 Optical/Electrical Mini I/O unit . . . . . . . . . . . . . . . . . . . . . . . . . . 38
6.10 Wideband Modem unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
7 Technical specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
7.1 General Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
7.2 Characteristics of 2 Mbit/s tributary interface (E1). . . . . . . . . . . . . . . . . 39
7.3 Characteristics of Ethernet ports interface. . . . . . . . . . . . . . . . . . . . . . . 407.4 SDH Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 4/43
4 A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
IDU Product Description
7.5 E1 ring protection switching time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
7.6 Characteristics of channel auxiliary interfaces . . . . . . . . . . . . . . . . . . . . 41
7.7 External alarms specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
7.8 System Power Supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 417.9 Power Consumption (from -48 V battery) . . . . . . . . . . . . . . . . . . . . . . . . 41
7.10 Mechanical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
7.11 Environmental characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
7.12 EMC/EMI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
7.13 Safety characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 5/43
A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
5
IDU Product Description
List of FiguresFigure 1 WEEE label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Figure 2 1+0 “FlexiHybrid” IDU configurations. . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Figure 3 1+1 “FlexiHybrid” IDU configurations. . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Figure 4 Indoor Section Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Figure 5 E1 processing block. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Figure 6 Block diagram for 42E1 Master IO module . . . . . . . . . . . . . . . . . . . . . . 17
Figure 7 Block diagram of 21E1 Expansion module . . . . . . . . . . . . . . . . . . . . . . 18
Figure 8 STM1 payload processing block (no RST termination) . . . . . . . . . . . . . 19
Figure 9 STM1 payload processing block (Crosspoint switch) . . . . . . . . . . . . . . 19
Figure 10 STM1 Mux/Demux . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Figure 11 Overhead Bytes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Figure 12 IDU block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Figure 13 Ethernet payload processing block . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Figure 14 NMS interface (SNMP) processing block. . . . . . . . . . . . . . . . . . . . . . . . 23
Figure 15 Alarm/Serial interface processing block. . . . . . . . . . . . . . . . . . . . . . . . . 24
Figure 16 Voice/Order Wire interface processing block. . . . . . . . . . . . . . . . . . . . . 25
Figure 17 IDU slots (front view) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Figure 18 Units layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Figure 19 Power Supply Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Figure 20 Controller and Controller2 Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Figure 21 Standard/Standard2 Master I/O Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Figure 22 Enhanced/Enhanced2 Master I/O Unit . . . . . . . . . . . . . . . . . . . . . . . . . 34
Figure 23 16 E1 Expansion I/O Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Figure 24 42xE1 Master I/O Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Figure 25 21x E1 Expansion I/O Unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Figure 26 Gigabit Ethernet/Gigabit Enhanced Ethernet Master I/O Unit . . . . . . . . 37
Figure 27 STM-1 Optical/Electrical Mini I/O unitt . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Figure 28 Wideband Modem unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Figure 29 Shape of 2 Mbit/s tributary interface output signal. . . . . . . . . . . . . . . . . 40
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 6/43
6 A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
IDU Product Description
List of TablesTable 1 Structure of this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Table 2 List of conventions used in this document . . . . . . . . . . . . . . . . . . . . . . . . 7
Table 3 History of changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Table 4 Units main functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Table 5 List of modules supported in FlexiHybrid appliance . . . . . . . . . . . . . . . . 26
Table 6 Reference table of IDU-Compositions supported . . . . . . . . . . . . . . . . . 27
Table 7 Possible Actions required for HW maintenance . . . . . . . . . . . . . . . . . . . 28
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 7/43
A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
7
IDU Product Description Preface
1 PrefaceThis document provides the technical description and the technical specifications of the
FlexiHybrid IDU.
1.1 Intended audience
This document is intended to the radio network planners and to the technicians in charge
to operate and maintain the FlexiHybrid IDU.
1.2 Structure of this document
The document is divided into the following main chapters:
1.3 Symbols and conventions
The following symbols and conventions are used in this document:
Chapter Title Subject
Chapter 1 Preface Provides an introduction and overview
of this Product Description
Chapter 2 Overview Provides an overview to the installation
Chapter 3 Functional description Provides the functional description of
the FlexiHybrid IDU
Chapter 4 Features Provides the main features
Chapter 5 Supported IDU Compositions Provides the list of the supported IDU
configurations
Chapter 6 External interfaces Provides the information regarding the
structure and the external interfaces of
the FlexiHybrid IDU
Chapter 7 Technical specifications Lists the technical data
Table 1 Structure of this document
Representation Meaning
Bold Text in the graphical user interface (window and wizard titles, field
names, buttons, etc.) is represented in bold face.
Example: Click Shutdown and then click OK to turn off the com-
puter.
Italic Field values, file names, file extensions, folder and directory
names are denoted by italic text.
Examples: Enter 192.168.0.1 in the IP address field. Click OK to
produce a .pdf file.
Table 2 List of conventions used in this document
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 8/43
8 A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
IDU Product DescriptionPreface
Screenshots of the graphical user interface are examples only to illustrate principles.
This especially applies to a software version number visible in a screenshot.
Courier Command and screen output are denoted by courier font.
Example: ping -t 192.168.0.1
<Angle brackets> Place holders for distinct names or values are represented by
enclosing them in <angle brackets>. If a file name is involved, italic
text will also be used.
Example: The naming convention for the log files is
<NEname>.txt , where <NEname> is the name of the NE sending
the messages.
Keyboard button Keyboard keys are represented with a surrounding box.
Example: Press Enter .
[Square brackets] Keyboard shortcuts are represented using square brackets.
Example: Press [CTRL+ALT+DEL] to open the Task Manager.
> The “>” symbol is used as short form to define a path through indi-
vidual elements of the graphical user interface, e.g., menus and
menu commands.
Example: On the Windows taskbar, select Start > Programs >
TNMS > Client menu command to start the TNMS Core/CDM
Client.
☞ A tip provides additional information related to the topic described.
g A note provides important information on a situation that can
cause property damage or data loss.
A note introduced in the text by the keyword NOTICE : describes a
hazard that may result in property damage but not in personal
injury.
f A safety message provides information on a dangerous situation
that could cause bodily injury.
The different hazard levels are introduced in the text by the follow-
ing keywords:
DANGER! - Indicates a hazardous situation which, if not avoided,
will result in death or serious (irreversible) personal injury.
WARNING! - Indicates a hazardous situation which, if not
avoided, could result in death or serious (irreversible) personal
injury.
CAUTION! - Indicates a hazardous situation which, if not avoided,
may result in minor or moderate (reversible) personal injury.
Representation Meaning
Table 2 List of conventions used in this document (Cont.)
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 9/43
A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
9
IDU Product Description Preface
1.4 History of changes
1.5 Waste electrical and electronic equipment (WEEE)
All waste electrical and electronic products must be disposed of separately from the
municipal waste stream via designated collection facilities appointed by the government
or the local authorities. The WEEE label (see Figure 1) is applied to all such devices.
Figure 1 WEEE label
The correct disposal and separate collection of waste equipment will help prevent poten-
tial negative consequences for the environment and human health. It is a precondition
for reuse and recycling of used electrical and electronic equipment.For more detailed information about disposal of such equipment, please contact Nokia
Siemens Networks. The above statements are fully valid only for equipment installed in
the countries of the European Union and is covered by the directive 2002/96/EC. Coun-
tries outside the European Union may have other regulations regarding the disposal of
electrical and electronic equipment.
1.6 RoHS compliance
FlexiPacket Radio complies with the European Union RoHS Directive 2002/95/EC on
the restriction of use of certain hazardous substances in electrical and electronic equip-
ment.The directive applies to the use of lead, mercury, cadmium, hexavalent chromium, poly-
brominated biphenyls (PBB), and polybrominated diphenylethers (PBDE) in electrical
and electronic equipment put on the market after 1 July 2006.
Materials usage information on Nokia Siemens Networks Electronic Information
Products imported or sold in the People’s Republic of China
FlexiPacket Radio complies with the Chinese standard SJ/T 11364-2006 on the restric-
tion of the use of certain hazardous substances in electrical and electronic equipment.
The standard applies to the use of lead, mercury, cadmium, hexavalent chromium, poly-
brominated biphenyls (PBB), and polybrominated diphenyl ethers (PBDE) in electrical
and electronic equipment put on the market after 1 March 2007.
Issue Issue date Remarks
1 October 2009 1st version
Table 3 History of changes
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 10/43
10 A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
IDU Product DescriptionOverview
2 OverviewThe indoor section consists of one IDU.
The IDU consists of baseband interfaces for data and management, two BB/Modemunits, a Controller unit, an Alarm Restitution Unit and a Fan unit. A single coaxial IF cable
connecting the BB/Modem unit with a very compact outdoor transceiver located close to
the antenna.
An unprotected 1+0 system consists of one assembly equipped with only one
BB/Modem unit; a 1+1 system consists of an assembly equipped with two BB/Modem
units.
Each BB/Modem unit is connected to the outdoor unit through a single coaxial cable
where main signal, indoor-outdoor service data and outdoor power supply are sent
together. The indoor unit is totally independent of the RF band chosen for the outdoor
unit, making the system very flexible and easy to deploy.
The STM-1 interface can be either electrical or optical.
Figure 2 shows the 1+0 IDU configurations.
Figure 3 shows the 1+1 IDU configurations.
Figure 2 1+0 “FlexiHybrid” IDU configurations
1+0 (minimum equipment) CONFIGURATION
Power Supply Unit 1
Controller Unit Cover
East Modem and
IF/Telemetry UnitMaster I/O Unit
Cover Cover
Cover
Power Supply Unit 1
Controller Unit E1 Expansion I/O Unit (op-
tional)
East Modem and
IF/Telemetry UnitMaster I/O Unit STM-1
Mini I/O Unit
Cover Cover
1+0 (maximum equipment) CONFIGURATION
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 11/43
A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
11
IDU Product Description Overview
Figure 3 1+1 “FlexiHybrid” IDU configurations
1+1 (minimum equipment) CONFIGURATION
Power Supply Unit 1
Controller Unit Cover
East Modem and
IF/Telemetry UnitMaster I/O UnitCover
Power Supply Unit 1
Controller Unit E1 Expansion I/O Unit
East Modem andIF/Telemetry UnitMaster I/O Unit STM-1
Mini I/O Unit
1+1 (maximum equipment) CONFIGURATION
Power Supply Unit 2
West Modem and
IF/Telemetry Unit
Power Supply Unit 2
West Modem and
IF/Telemetry Unit
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 12/43
12 A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
IDU Product DescriptionFunctional description
3 Functional descriptionFigure 4 shows the block diagram of the IDU.
Figure 4 Indoor Section Block Diagram
Figure 4 shows the IDU and interfaces from a functional point of view as weel as the
functional parts of the I/O, Modem/IF, and power supply modules. The IDU comes with
the standard I/O facility which can be upgraded. In addition, the Modem/IF function is
modular. This allows the addition of a second Modem to support protection or ring archi-
tectures. The power supply is similarly modular too.
The major functions of the IDU can be summarized as follows:
– I/O Processing - The IDU comes with a standard I/O facility that includes support for
up to 16xE1 and 2x100Base-TX user payloads, 2x100Base-TX for SNMP, and voice
orderwire. Moreover, 1 x STM-1, can be added. The IDU architecture is flexible and
allows for the future addition of other I/O types.
– Switch/Framing - The IDU includes an Ethernet Switch and a proprietary Framer that
are designed to support 1+1 protection switching, ring architecture routing, and
overall network control functions.
– Network Processor - The IDU includes a Network Processor which performs SNMP
and Network Management functions.
– Modem/IF - The IDU Modem performs forward-error-correction (FEC) encoding,
PSK/QAM modulation and demodulation, equalization, and FEC decoding func-
tions. The IF chain provides a 350 MHz carrier and receives a 140 MHz carrier. The
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 13/43
A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
13
IDU Product Description Functional description
built-in multiplexer function resides in the Modem/IF Module. Two modems can be
used for 1+1 protection or ring architectures.
– Power Supply - The IDU power supply accepts 48 Vdc and supplies the IDU and
ODU with power. A second redundant power supply may be added as an optional
module.
– For the STM-1 configuration, a user rate clock is recovered from clock recovery
NCO and provided to the STM-1 I/O card.
The Modem Processor and its associated RAM, ROM, and peripherals control
Modem/IF operation. The IDU interfaces the ODU to receive and provide modulated Tx
and Rx waveforms.
The Modem modulates and demodulates of the payload/wayside/SNMP data and
forward error correction using advanced modulation and coding techniques. By means
of the all-digital processing used, the Modem implements strong modulation and forward
error correction coding to minimize the number of bit errors and optimize the radio and
network performances.The Modem also scrambles, descrambles and interleaves/deinterleaves the data
stream in accordance with Intelsat standards to ensure modulation efficiency and resil-
ience to sustained burst errors. The modulation will vary by application, data rate, and
frequency spectrum. The highest order modulation mode supported is 128 Quadrature
Amplitude Modulation (QAM).
The IDU also provides the physical interface for the user payload and network manage-
ment. In the transmit mode, the Framer merges user payload with radio overhead-
encapsulated network management data. This combined data stream is transmitted
without any loss of user bandwidth. In the receive mode, the Framer separates the
combined data stream received from the Modem. The IDU supports Scalable Ethernet
data rates, such as 25 or 50 Mbps via the 100BaseT data interface port. The IDUprovides network management data on 10 Mbps ports accessible via the 10/100BaseTX
port. The Central Processor Unit (CPU) provides the embedded control and network
element functionality of the OAM&P. The CPU also communicates with other functions
within the IDU for configuration, control, and status monitoring. The CPU passes appro-
priate status information to the IDU front panel display.
The power supply converts -48 Vdc to the DC voltage levels required by each compo-
nent in the system.
The following table summarizes the main functions performed by each unit.
Unit Performed Logical function Note
Controller unit • IDU programming and supervision
• NMS management (SNMP)
• Alarm remotization (input and Putput)
Master IO unit • Process User Payload
• Manage Framer
• Manage Crosspoint Switch
• Provide Voice Orderwire
• Provides Data Orderwire
Note that Framer/Crosspoint Switch
is housed on Master IO card, this
means that switching and framing
capacity of the IDU depend on the
type of equipped Master I/O module.
Table 4 Units main functions
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 14/43
14 A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
IDU Product DescriptionFunctional description
In SVR 2.1 the following new units have been inserted:
– Controller2 unit (par 3.1)
– Standard2 Master IO unit (par 3.2)
– Enhanced2 Master IO unit (par 3.2)
– Enhanced GigE Master IO unit (par 3.3)
3.1 Controller2 Module
The "Controller2" Module is a new version of the Controller Module and provides
upgraded capabilities. It fits the same slot as the Controller Module and provides the
same front panel connections.
The Controller2 Module, with respect to the Controller Module has a Different Ethernet
switch: the one adopted in 42E1 Master Module is used in the Controller2 Module to
manage the NMS channel. The new switch is transparent to the user. There are no
changes to functionalities (e.g. Max MTU, NMS, etc) and there are no changes to the
SNMP MIBs. Full interoperability between Controller and Controller2. 4096 MACaddresses in Controller, 1024 MAC addresses in Controller2, Aging time: 300 s for Con-
troller and 300 s in Controller2.
The Controller2 module has 32Mbyte of FLASH memory as the Controller module.
3.2 Standard2 Master IO and Enhanced2 Master IO Modules
The "Standard2" Master IO Module and "Enhanced2" are new versions of the Standard
and Enhanced Master IO Modules, respectively. Moreover they provide upgraded capa-
bilities of the respective older module versions; they fit the Master IO Module slot and
provide the same front panel connections as the respective Standard and Enhanced
Optional I/O units • Provide additional payload capabilities
Modem/IF unit •
Forward-error-correction (FEC) encod-ing/decoding
• QPSK, 16QAM, 32QAM, 64QAM, 128QAM
modulation and demodulation
• Bandwidths: from 7MHz to 28MHz.
• Carrier Recovery
• Timing Recovery
• Equalization
• The IF chain
– Transmit: 350 MHz carrier
– Receive: 140 MHz carrier
• IDU-ODU Telemetry
Power Supply unit • Accepts -48 Vdc
• Provides power to IDU and ODU
No mechanical switch for IDU nor
ODU power up is present
Unit Performed Logical function Note
Table 4 Units main functions (Cont.)
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 15/43
A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
15
IDU Product Description Functional description
Master Modules. Standard 2 and Enhanced2 Master Modules are over-the-air compat-
ible with the already supported Master IO Modules.
Here follows the list of the main differences of both the new Modules with respect to the
Standard and Enhanced Modules, respectively. – Different Ethernet Switch (the same switch used in the 42E1 Master Module is
adopted). This resulted in enhanced QoS capabilities.
– Voice Order Wire Enhancements: the new Modules support party line VOW in
addition to the point-to-point mode previously supported. The party line mode was
already supported for the 42E1 Master IO Module. Two operating modes are sup-
ported: point-to-point and party line. The party line mode allows the voice traffic to
be sent to both east and west links if so selected by the user. When the party line
mode is selected, the handset's earpiece is fed summed voice data from both the
east and west links.
3.3 Enhanced GigE Master IO Module
This module is the same as the GigE Master IO Module with the features of the STM-1
Mux/Demux.
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 16/43
16 A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
IDU Product DescriptionFeatures
4 Features
4.1 Payload Processing And User Interface FunctionalitiesPayload interfaces are: E1, STM1, Ethernet.
4.1.1 E1 payload processing (Standard, Standard2, Enhanced and
Enhanced2 Master I/O Unit)
The logical processing scheme is shown in Figure 5: E1s can be cross-connected
towards the Modems or User interface
Figure 5 E1 processing blockPerformance monitoring is not available for E1 payload. AIS and LOS alarms are avail-
able for each E1 channel.
4.1.2 E1 payload processing (42xE1 Master I/O Unit and 21xE1 Expansion
unit)
The core of the payload processing (framer, cross-point switch and interface with
modems) is housed in the Master IO module.
Figure 6 and Figure 7 describe the block diagram for 42xE1 master module and 21xE1
Expansion module.
The framer, included in the Master module, can manage the 42xE1 interfaces on the
front panel and the 21xE1 interfaces present on the front panel of 21xE1 Expansion
module.
The overall capability is 63 E1. The cross-point switch of the 42xE1 Master module is an
any-to-any Crosspoint Switch that allows E1 signals to be routed between front-panel
ports, east/west timeslots or ring timeslots.
Near and Far loopbacks are available for each E1 present on both 42xE1 master module
and 21xE1 expansion module.
Performance monitoring is not available for E1 payload.
AIS and LOS alarms are available for each E1 channel.
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 17/43
A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
17
IDU Product Description Features
Figure 6 Block diagram for 42E1 Master IO module
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 18/43
18 A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
IDU Product DescriptionFeatures
Figure 7 Block diagram of 21E1 Expansion module
4.1.3 STM1 payload processing
4.1.3.1 Multiplexing structure
If Mux/Demux option is not used the STM1 is transparently transported. In this case the
IDU is a pure transport, no RST termination is performed: this is the only case supported
by SVR 1.0 (see Figure 8).
g The Mini IO module with STM1 interface can not be equipped when the 42xE1
master module is present . As a consequence:
– The Mux/Demux option is not applicable to the 42E1 Master module.
– It is not possible to transport the STM1 from line side to the radio side when
42E1 master module is used. Modes that include the STM1 rate can be config-
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 19/43
A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
19
IDU Product Description Features
ured but they reserve an STM1 channel over the air that can not be managed
line-side.
Figure 8 STM1 payload processing block (no RST termination)
From SVR 1.1 the Mux/Demux option is available. This option requires the Expanded
Master IO module.The only structure that can be managed via Mux-Demux is TUG3-
VC12 (Asynchronous mapping) and the entire frame (63VC12) is completely termi-nated. This means that there is no pure SDH Add/Drop capability because the frame
over the air is not STM1 but it is a proprietary frame. Consequently this application has
no RST, nor MST regeneration processing, but the line-side termination is implemented.
STM1 clock is not transported over the air.
Mixed TUG3 structures are not supported.
Figure 9 STM1 payload processing block (Crosspoint switch)
Figure 10 STM1 Mux/Demux
Crosspoint switch provides any-to-any routing of E1s between front-panel ports, east
link, west link, and STM-1 Mux/Demux
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 20/43
20 A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
IDU Product DescriptionFeatures
STM-1 Mux/Demux Option (From SVR 1.1)
– Provides for a STM-1 Terminal Mux/Demux capability
– It can Mux/Demux up to 63 x E1 from an STM-1 signal
– Performance monitoring via WebGUI and SNMP – Only the front-panel STM-1 signal may be routed to the STM-1 Mux/Demux
• E1s to be aggregated across multiple IDU nodes must be transmitted over the air as
E1s with the final IDU performing the STM-1 Mux/Demux
The SDH Regenerator Section Overhead bytes are processed as follows (line side,
incoming IDU):
– J0 - Regenerator Section Trace message sent on Tx, and received on Rx. The Rx
Path Trace message is compared to an expected message and an Alarm is raised
if they differ.
– E1 - Not used, but supportable based on interoperating equipment.
– F1 - Not used, but supportable based on interoperating equipment. – DCC1-3 - Not used, but supportable based on interoperating equipment.
The SDH Multiplex Section Overhead bytes are processed as follows (line side,
incoming IDU):
– E2 - Not used, but supportable based on interoperating equipment.
– DCC4-12 - Not used, but supportable based on interoperating equipment.
The SDH Path Section Overhead bytes are processed as follows (line side, incoming
IDU):
– J1 - Path Trace message sent on Tx, and received on Rx. The Rx Path Trace
message is compared to an expected message and an Alarm is raised if they differ.
– C2/V5 - Path Label. Transmitted C2 is always 02h (TUG). Transmitted V5 is either
00h (unequipped if VC is not in channel map) or 02h for Asynchronous mapping (not
configurable by the User). Received C2/V5 are monitored and alarms raised accord-
ingly.
The not used outgoing line side SOH Bytes are set to "0".
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 21/43
A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
21
IDU Product Description Features
Figure 11 Overhead Bytes
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 22/43
22 A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
IDU Product DescriptionFeatures
4.1.3.2 SDH Performance Monitoring
SDH performance monitoring parameters are available in case of Mux-Demux option.
STM1 Mux/Demux option is managed from SVR 1.1.
SNMP As Per RFC-2558: Definitions of Managed Objects for the SONET/SDH Interface
Type
– GUI
– Configure STM-1 Mux/Demux parameters
• Trace messages, SONET/SDH, STM-0/1, Scrambling, REI, RDI
– Graphs
• ESs, SESs, CVs, SEFs for Regenerator Section
• ESs, SESs, CVs, UASs for Multiplex Section
Graphs have 15 min granularity and they are displayed at the end of the quarter.
4.1.4 Ethernet payload Processing
The switch block in the diagram of Figure 12 is a standard Ethernet switch, with two (or
more) ports connected to the front-panel and two ports connected to the Framer (one
port for each modem). The Ethernet switch manages traffic using source and destination
addresses and forwards traffic to the appropriate ports.
The standard Ethernet switch allows traffic forwarding between the front-panel ports.
Refer to Figure 13.
Figure 12 IDU block diagram
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 23/43
A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
23
IDU Product Description Features
Figure 13 Ethernet payload processing block
4.1.5 NMS interface (SNMP)
Figure 14 NMS interface (SNMP) processing block
• The equipment supports SNMP for network management
– SNMPv1, SNMPv2
– SSH and SNMPv3 has been removed from IDu software for export control law.
– SNMP Traps
• The equipment supports industry standard MIBs in addition to proprietary MIBs
– RFC-1213 (MIB-II)
– RFC-2863 (The Interfaces Group MIB)
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 24/43
24 A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
IDU Product DescriptionFeatures
– RFC-3635 (Ethernet-like Interface)
– RFC-2558 (SDH Interface)
– RFC-3985 ( E1 Interface)
• The equipment supports remote alarms and messages logging to a Syslog serveras specified in RFC3164
– Per RFC3164: "In its most simple terms, the syslog protocol provides a transport to
allow a machine [e.g. the IDU] to send event notification messages across IP
networks to event message collectors - also known as syslog servers."
• E-mail notifications
• The “FlexiHybrid” does not support NMS traffic routing.
• Spanning Tree is supported for NMS interface.
4.2 Serial/Alarm management
Figure 15 Alarm/Serial interface processing block
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 25/43
A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
25
IDU Product Description Features
4.3 Voice/Order Wire
Figure 16 Voice/Order Wire interface processing block
Voice and Data Order wire enabling is contained in Modes file and configured via Config
Tool.
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 26/43
26 A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
IDU Product DescriptionSupported IDU Compositions
5 Supported IDU Compositions This section contains the description of all the modules supported by FlexiHybrid and
the released IDU composition.
Figure 17 shows the IDU structure, and the physical position of the slots that can be
equipped with different module types. Some modules are mandatory for all IDU config-
urations and other are expansion or optional.
Figure 17 IDU slots (front view)
For each slot the Table 5 contains the list of possible module type that can be plugged
in the slot.
IDU Slot Module Short
Name
Short Module Description SVR that support
the module
Chassis Chassis Wired rack From SVR 1.0
Power Supply [1 or 2] PS Power Supply From SVR 1.1
Controller Controller Controller unit From SVR 1.1 but
not in SVR 2.0
Controller2 New Controller unit with USB key enabling From SVR 2.0
Modem [East or West] Modem7-56 Wideband Modem/IF module Customized for
NSN
From SVR 1.2
Master I/O Standard Standard IO module with 16E1+2Ethernet From SVR 1.0 but
not in SVR 2.0
Standard2 New Standard module From SVR 2.0
Enhanced Enhanced Master I/O module From SVR 1.0 but
not in SVR 2.0
Ehnanced2 New Enhanced module From SVR 2.0
GigE GigE Master I/O module with 2E1+Eth From SVR 1.0
EnhGigE Enhanced GigE Master IO module
w/2E1+Ethernet
From SVR 2.1
42E1 Master 42E1 IO module w/ 42E1+Ethernet From SVR 1.2
Mini I/O STM1o STM-1 Optical Mini IO module From SVR 1.0
STM1e STM-1 Electrical Mini IO module From SVR 1.0
Table 5 List of modules supported in FlexiHybrid appliance
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 27/43
A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
27
IDU Product Description Supported IDU Compositions
The combinations of modules supported are described in Table 6. Each combination is
here named as "IDU-Composition".
Each IDU composition has a short name that summarise the user payload interface and
the main modules.
Expansion I/O Exp 16E1 16E1 expansion IO module From SVR 1.0
Exp 21E1 21E1 expansion IO module From SVR 1.2
IDU Slot Module Short
Name
Short Module Description SVR that support
the module
Table 5 List of modules supported in FlexiHybrid appliance (Cont.)
ID ref IDU composition
Name
Equipped Modules Notes
ControllerSlot
Master Slot ExpandedSlot
Mini IO slot
1 IDU 16 E1 Controller Standard - 1) -1) IDU composition sup-
ported but not order-
able.
IDU compositions
already in field.
They can be upgraded
to SVR 2.0
2 IDU 32 E1 Controller Standard 16E1 -
3 IDU STM1e Controller Enhanced - STM1e
4 IDU STM1o Controller Enhanced - STM1o
5 IDU GigE Controller GigE - -
6 IDU GigE 18 Controller GigE 16E1 -
7 IDU 42E1 Controller - - -
8 IDU 63E1 Controller 42E1 21E1 -
1o IDU 16 E1 (o) Controller2 Standard2 - - IDU composition sup-
ported and available for
new orders when the
2.0 will be released
2o IDU 32 E1 (o) Controller2 Standard2 16E1 -
3o IDU STM1e (o) Controller2 Enhanced2 - STM1e
4o IDU STM1o (o) Controller2 Enhanced2 - STM1o
5o IDU GigE (o) Controller2 GigE - -
6o IDU GigE 18 (o) Controller2 GigE 16E1 -
7o IDU 42E1 (o) Controller2 42E1 - -
8o IDU 63 E1 (o) Controller2 42E1 21E1 -
9o IDU EnhGig E
STM1e (o)
Controller2 EnhGigE 16E1 STM1e
10o IDU EnhGig E
STM1o (o)
Controller2 EnhGigE 16E1 STM1o
Table 6 Reference table of IDU-Compositions supported
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 28/43
28 A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
IDU Product DescriptionSupported IDU Compositions
Note that Table 6 is a summary of all the IDU-Compositions available in SVR 2.1. The
complete set of IDU-compositions can be obtained applying the following rules to the
Table 6:
– Each row (ID ref) corresponds to 2 IDU-Compositions: the 1+0 and 1+1.
– In 1+0 the PS1 slot must be equipped with PS module. Modem East slot must be
equipped with Modem7-56.
– In 1+1 the PS1 and PS2 slots must be equipped with the PS module. Modem East
and Modem West slots must be equipped with Modem7-56.
The IDU compositions to be supported have been selected on the basis of the possibility
to replace the Controller, Standard and Enhanced modules with the newer module ver-
sions. Table 7 describes the maintenance actions that can be performed when and if
necessary.
1m IDU 16 E1 (m) Controller2 Standard - - IDU-Combination to
support controller
replacement2m IDU 32 E1 (m) Controller2 Standard 16E1 -
3m IDU STM1e (m) Controller2 Enhanced - STM1e
4m IDU STM1o (m) Controller2 Enhanced - STM1o
1) "-" means empty slot.
ID ref IDU composition
Name
Equipped Modules Notes
Controller
Slot
Master Slot Expanded
Slot
Mini IO slot
Table 6 Reference table of IDU-Compositions supported (Cont.)
Maintenance
Action
Installed IDU -
Composition
IDU - Composition
after maintenance
Action
Required Actions
Replacement of
Controller
1 1m Controller2 is used to
replace the Controller.
SVR shall be upgraded to
2.1 for both sides of the link.
2 2m
3 3m
4 4m
5 5o Controller2 is used to
replace the Controller.SVR shall be upgraded to
2.1 for both sides of the link.
6 6o
7 7o
8 8o
Replacement
of Standard
module
1 1o Both Master and Controller
modules must be
replaced.SVR shall be
upgraded to 2.1 for both
sides of the link.
2 2o
Replacement of
Enhanced
module
3 3o
4 4o
Table 7 Possible Actions required for HW maintenance
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 29/43
A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
29
IDU Product Description Supported IDU Compositions
Note that previous SVRs (from 1.1 to 1.4) do not support the new Modules (Controller2,
Standard2, Enhanced2 and EnhGigE). Consequently if a new module is required to be
plugged in one IDU the link shall be upgraded to SVR 2.1 according to the module type.
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 30/43
30 A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
IDU Product DescriptionExternal interfaces
6 External interfacesFigure 18 shows the layout of the indoor assembly units.
Figure 18 Units layout
Power Supply Unit 1
Power Supply Unit 2 (optional) Controller Unit E1 Expansion I/O Unit
West Modem andIF/Telemetry Unit
East Modem and
IF/Telemetry UnitMaster I/O Unit STM-1 optical
Mini I/O Unit
STM-1 optical
Mini I/O Unit
(altern.)
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 31/43
A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
31
IDU Product Description External interfaces
6.1 Power Supply Unit
Figure 19 Power Supply Unit
Power Supply Unit Features:
– Requires isolated input of –48 Vdc ± 10%
• Recommended power input is –40 to –60 Vdc at 2 Amps
• Total required power is based on option cards and configuration (1+ 0, 1+ 1) – Pin 1 (power supply return) is internally connected to unit chassis ground
– The IDU supplies the ODU with all the power needed
– The IDU has no on/ off switch
– Phoenix Contact P/ N 17 86 83 1
– Provided with “FlexiHybrid” for construction of power cable
– Screw clamp terminals
• Accommodate 24 AWG – 12 AGW wire
• 18 AWG is recommended for cables under 3m
• Pin 2 (labeled –V) to –48 Vdc
• Pin 1 (labeled RET) to power supply return
Power/ Fault
LEDPower Input
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 32/43
32 A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
IDU Product DescriptionExternal interfaces
6.2 Controller and Controller2 Unit
Figure 20 Controller and Controller2 Unit
Controller Unit Features:
– NMS
• 10/ 100Base- TX RJ- 45 modular local port connectors
• Port 1:- Access to Network Management System (SNMP) and GUI
• Port 2:
- Access to Network Management System (SNMP)
- Used for consecutive point networks
– Alarms/ Serial
• DB- 15HD female connector
• 2 Form- C relay alarm outputs:
- Rated load: 1A @ 24 Vdc
- Can be configured to emulate TTL alarm outputs
• 2 TTL alarm outputs
• 4 TTL alarm inputs
• Serial Console
– USB
• Future use
– Ground Lug
• Ground connection for “FlexiHybrid”
• One of two possible ground locations
Status
LED
NMS
Ethernet
Alarms/Serial
Interface
USB
(Future use)
Groung Lug
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 33/43
A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
33
IDU Product Description External interfaces
6.3 Standard/Standard2 Master I/O Unit
Figure 21 Standard/Standard2 Master I/O Unit
Standard Master I/O Features:
– User Payload Data: Ethernet
• 10/ 100Base- TX RJ- 45 modular local port connectors
•
Port 1: Fast Ethernet interface • Port 2: Used for consecutive point networks
– Voice Orderwire
• RJ- 45 modular port connector
• Provides a PTP connection via a PTT handset and buzzer
– Call button
• Initiates a Voice Orderwire ring
• Only “FlexiHybrid” link partner receives ring
– Data Orderwire
• RJ-45 modular port connector
• RS-422 up to 64 kbps
• RS-232 up to 19.2kbps”
– E1 Channels
• 2 E1 (RJ-48C) interface connections
• Single Molex 60-pin connector containing 14 E1 connections
• E1:120 Ohm Balanced
• 223 x E1 Crosspoint Switch
– Ground Lug
• Ground connection for “FlexiHybrid”
• One of two possible ground locations
Status
LED
Call
Button
User
Ethernet Data
Voice
Orderwire2 x
E1
Data
Orderwire
Groung
Lug14x
E1
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 34/43
34 A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
IDU Product DescriptionExternal interfaces
6.4 Enhanced/Enhanced2 Master I/O Unit
Figure 22 Enhanced/Enhanced2 Master I/O Unit
Enhanced Master I/O Features:
– Same features as Standard Master I/ O Unit
– Support for STM- 1 Mux/ Demux
6.5 16 E1 Expansion I/O unit
Figure 23 16 E1 Expansion I/O Unit
16 E1 Expansion I/O unit Features:
– E1 Channels
• 2 E1 (RJ-48C) interface connections
• Single Molex 60-pin connector containing 14 E1 connections
• E1:120 Ohm Balanced
Status
LED
Call
Button
User
Ethernet Data
Voice
Orderwire
2 x
E1
Data
OrderwireGroung
Lug
14x
E1
Status
LED
2 x
E1
14x
E1
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 35/43
A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
35
IDU Product Description External interfaces
6.6 42xE1 Master I/O Unit
Figure 24 42xE1 Master I/O Unit
42xE1 Master I/O Features:
– User Payload Data: Ethernet
• 10/ 100Base- TX RJ- 45 modular local port connectors
• Port 1: Fast Ethernet interface
• Port 2: Used for consecutive point networks
– Voice Orderwire
• RJ- 45 modular port connector
• Provides a PTP connection via a PTT handset and buzzer
– Call button• Initiates a Voice Orderwire ring
• Only “FlexiHybrid” link partner receives ring
– Data Orderwire
• RJ-45 modular port connector
• RS-422 up to 64 kbps
• RS-232 up to 19.2kbps”
– E1 Channels
• 3x Molex 60-pin connector containing 14 E1 connections
• E1:120 Ohm Balanced
• 191 E1 Crosspoint Switch (64 East, 64 West, 63 Front panel)
– Ground Lug
• Ground connection for “FlexiHybrid”
• One of two possible ground locations
Status
LED
Call
Button
Groung
LugUser
Ethernet Data
Voice
Orderwire
Data
Orderwire
14x
E114x
E1
14x
E1
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 36/43
36 A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
IDU Product DescriptionExternal interfaces
6.7 21x E1 Expansion I/O unit
Figure 25 21x E1 Expansion I/O Unit
21x E1 Expansion I/O unit Features:
– E1 Channels
• Two Molex 60-pin connector containing:
one 14 E1 connections
one 7 E1 connections
• E1:120 Ohm Balanced
Status
LED
7x
E1
14x
E1
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 37/43
A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
37
IDU Product Description External interfaces
6.8 Gigabit Ethernet/Gigabit Enhanced Ethernet Master I/O
Unit
Figure 26 Gigabit Ethernet/Gigabit Enhanced Ethernet Master I/O Unit
Gigabit Ethernet Master I/O Features:
– User Payload Data: Ethernet
• 4x10/1001000Base-TX modular local port connectors • SFP Slot (1000Base-TX, 1000Base-SX,1000Base-LX)
– Support for STM-1 Mux/Demux (only with Gigabit Enhanced Ethernet Master IO
Unit)
– Voice Orderwire
• RJ- 45 modular port connector
• Provides a PTP connection via a PTT handset and buzzer
– Call button
• Initiates a Voice Orderwire ring
• Only “FlexiHybrid” link partner receives ring
(Point-to-Point mode)
• All “FlexiHybrid” in consecutive point network received ring
(Party Line mode)
– Data Orderwire
• RJ-45 modular port connector
• RS-422 up to 64 kbps
• RS-232 up to 19.2kbps”
– E1 Channels
• E1 (RJ-48C) interface connections
• Single Molex 60-pin connector containing 14 E1 connections
• E1:120 Ohm Balanced
• 223 x E1 Crosspoint Switch
– Ground Lug
• Ground connection for “FlexiHybrid”
• One of two possible ground locations
Status
LED
Call
Button
User
SFP Module
User
Ethernet Data
Groung
Lug
Voice
Orderwire
2 x
E1
Data
Orderwire
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 38/43
38 A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
IDU Product DescriptionExternal interfaces
6.9 STM-1 Optical/Electrical Mini I/O unit
Figure 27 STM-1 Optical/Electrical Mini I/O unitt
STM-1 Optical/Electrical Mini I/O unit Features:
– STM-1 Optical
• SC connectors
• Single Mode, SC Duplex Fiber 1310 nm
– STM-1 Electrical
• BNC connectors
• 75 Ohm BNC Coax
6.10 Wideband Modem unit
Figure 28 Wideband Modem unit
Wideband Modem Features:
– ODU
• TNC female connector
• Provides
- -48 Vdc to ODU
- 350 MHz Transmit IF to ODU (-10 dBm)
- Telemetry
• Receives
- 140 MHz Receive IF from ODU (-5 to –30 dBm)
- Telemetry
- ODU-IDU Interconnect Cable
Provides Assuming ODU input requirement of –30 dBm and output >-15 dBm
– Wideband Modem and IF/Telemetry Module
– 7MHz and 28MHz bandwidth
STM- 1
Optical
STM- 1
Electrical
ODU
Connection
Status
LED
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 39/43
A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
39
IDU Product Description Technical specifications
7 Technical specifications
g The values reported in this document are the nominal values.
7.1 General Electrical Characteristics
Traffic capacity:
• Standard PDH configuration:
– up to 16xE1 (E1 traffic only)
– up to 155 Mbps (Eth traffic only)
– several combinations of E1 and Eth traffic depending on selected
modulation and channel bandwidth
• Super PDH configuration:
– up to 63xE1 (E1 traffic only)
– up to 155 Mbps (Eth traffic only)
– several combinations of E1 and Eth traffic depending on selected
modulation and channel bandwidth
• GigaEthernet configuration:
– up to 300 Mbps in (1+0)
• SDH configuration:
– 1xSTM-1 Optical or Electrical
7.2 Characteristics of 2 Mbit/s tributary interface (E1)
- Bit rate 2048 kbit/s ± 50 ppm- Code HDB3
- Pulse shape see Figure 29
- Load impedance 120 Ohm
- Nominal peak voltage of a mark (pulse):
- 120 ohm 3 V
- Nominal peak voltage of a "space" (no pulse)
- 120 ohm 0 ± 0.3 V
- Nominal pulse length 244 ns
- Output return loss ≥ 10 dB,
for f = 51.2 to 3072 kHz
- Input return loss:
- f = 51 to 102 kHz ≥ 18 dB
- f = 102 to 2048 kHz ≥ 22 dB
- f = 2048 to 3072 kHz ≥ 18 dB
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 40/43
40 A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
IDU Product DescriptionTechnical specifications
Figure 29 Shape of 2 Mbit/s tributary interface output signal
7.3 Characteristics of Ethernet ports interface
7.4 SDH Interface
7.5 E1 ring protection switching time
Standard IEEE 802.3 (10Base-T)
IEEE 802.3u (100Base-Tx
IEEE 802.3z (Gigabit Ethernet)
Port 10Base-T or 100Base-Tx, available on one
connector RJ-45
1000BaseTx or 1000Base-SX or 1000Base-Lx
on one SFP module
Duplex half / full duplex
STM-1 (155.52 Mbit/s):
- electrical ITU-T G.703
- ptical ITU-T G.957 S1.1
Typical switching time 50 ms
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 41/43
A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
41
IDU Product Description Technical specifications
7.6 Characteristics of channel auxiliary interfaces
Data Orderwire (Software selectable)
Voice Orderwire
The voice orderwire provides a PTP connection via a PTT handset and buzzer. The call
button on the Master I/O unit activates a call. Only the IDU link partner will receive the
call.
VOW does not call all nodes or support "party line" calls.
7.7 External alarms specificationsDB-15HD female connector for :
– two Form-C relay alarm outputs (rated load: 1A @ 24 VDC),
– two TTL alarm outputs, four TTL alarm inputs
(The two Form-C relay alarm outputs can be configured to emulate TTL alarm outputs)
7.8 System Power Supply
The power supply meets ETSI Recs. EN 300-132-2:
7.9 Power Consumption (from -48 V battery)
up to 19.2 kbps (RS232)
or
up to 64 kbps (RS422)
Nominal voltage -48 Vdc
IDU 1+0 30 W
IDU 1+1 60 W
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 42/43
42 A25000-A0300-F018-01-76P1
Issue: 1 Issue date: October 2009
IDU Product DescriptionTechnical specifications
7.10 Mechanical characteristics
The mechanical characteristics of the indoor equipment are in accordance with the stan-
dards as defined by ETSI (EN 300 119-3, 4, rack and subrack respectively).
7.11 Environmental characteristics
The equipment meets the environmental conditions:
The racks are so dimensioned:
- height 2200 mm
- width 600 mm
- depth 300 mm
The IDU sub-rack has the following dimensions:
- standard shelf 2 U (ETSI and 19”)
Weight of modules
- ETSI rack 57 Kg
- Indoor Unit (fully equipped) 5 Kg
Normal conditions: Class 3.2
Temperature limits -5 to +50°C
Humidity limits 5% to 95%
Maximum temperature limit Up to +55°C(without perma-
nent damages)
7/17/2019 IDU Product Description
http://slidepdf.com/reader/full/idu-product-description 43/43
IDU Product Description Technical specifications
7.12 EMC/EMI
The equipment complies with the EMI/EMC parameters according to the above listed
standards and to ETSI standards EN 301 489-1 e EN 301 489-4.
N.B.:
7.13 Safety characteristics
Electrostatic discharge according to EN 61000-4-2, criterion 1
Level 2 (± 4kV contact), level 3 (± 8kV air),
RF electromagnetic field immunity
(80-2000 MHz)
according to EN 61000-4-3, criterion 1
(3 V/m for IDU and 30 V/m for ODU)
Electrical Fast Transient/Burst
(EFT/B) immunity
accord. to EN 61000-4-4, Level 3, criterion 1
Surge immunity accord. to EN 61000-4-5, criterion 2
Class 2 (Signal and control lines 0.5kV)
Resistibility 5kV on the IDU/ODU cable according to
EN 61000-4-5Radio frequency common mode
(0.15-80 MHz)
accord. to EN 61000-4-6, Level 2 (3 Vrms)
criterion 1
Conducted emission according to EN 55022/CISPR22, Class A
Radiated emission according to EN 55022/CISPR22, Class A
Criterion 1: no degradation of normal performance (no errors)
Criterion 2: degradation of normal performance / loss of functionality, with auto
recovery
Safety according to EN 60950-1