18
Trade Mark: Döndü AYDIN Test Mühendisi (Test Engineer) Test Yapan Personel ( ad, unvan): Tested by (name, function / signature) IES LM 79-08 DENEY RAPORU IES LM 79-08 TEST REPORT İmza: Rapor Yayım Tarihi: BAYTAŞ AYDINLATMA Ahi Evran Mah. 225. Cad. No:84 Sincan / ANKARA 23.07.2020 23.07.2020 Customer name/address Müşteri Logosu/Markası: Date of test Turkish Accreditation Agency (TURKAK) is a signatory to the European co-operation for Accreditation (EA) Multilateral Agreement (MLA) and to the International Laboratory Accreditation Cooperation (ILAC) Mutual Recognition Arrangement (MRA) for the recognition of test reports The date of receipt of test item Sample No.: Deneyin yapıldığı tarih : Report approval date Number of pages of the Report Deney Raporunu Onaylayan Personel (ad, unvan): Approved by (name, function / signature) 18 S20T6/0721/064+008-01/01-01/N01 Fatih KARA Laboratuvar Müdürü (Laboratory Manager) Türk Akreditasyon Kurumu(TÜRKAK) deney raporlarının tanınırlığı konusunda Avrupa Akreditasyon Birliği(EA) ile Çok Taraflı Anlaşma ve Uluslararası Laboratuvar Akreditasyon Birliği(ILAC) ile karşılıklı tanıma anlaşması imzalamıştır. Rapor onay tarihi: Raporun sayfa sayısı : 23.07.2020 Numune Numarası : Numunenin kabul tarihi : Report release date BAYLED COSMO-24W-4K-70CRI-Zemine Gömme Aydınlatma Armatürü BAYLED COSMO-24W-4K-70CRI-Floor Recessed Lighting Luminaire 23.07.2020 Numunenin adı ve tarifi : Name and identity of test item This report shall not be reproduced other than in full except with the permission of the laboratory.Testing reports without signature and seal are not valid. İmza: AB-0678-T 20T6064+008/ N0120/40 07-20 * İşaretli deneyler veya akreditasyon numarasının yer almadığı sayfalar, akreditasyon kapsamı dahilinde değildir. (Bkn: Test performans.) (*signed tests or the papers which have not the accreditation number are not in the scope of accreditation. See: Tests performed) (The test and/or measurement results, the uncertainties (if applicable) with confidence probability and test methods are given on the following pages which are part of this report.) Bu rapor; Laboratuvarımıza müşteri tarafından ulaşan numuneye deney ve/veya deneyler uygulanarak elde edilmiştir. Numune Numarası kısmında belirtilen numune(ler) hariç, müşteriye ait diğer numuneleri kapsamaz. (This report was prepared after applying test/tests to the sample that are sent to our laboratory by customer.) (Except for the sample specified in the sample(s) number, note that this report does not involve other samples of the customer.) Deney ve/veya ölçüm sonuçları, genişletilmiş ölçüm belirsizlikleri (olması halinde) ve deney metotları bu sertifikanın tamamlayıcı kısmı olan takip eden sayfalarda verilmiştir. Müşterinin adı/adresi : Bu rapor laboratuvarın yazılı izni olmadan kısmen kopyalanıp çoğaltılamaz.İmzasız ve mühürsüz raporlar geçersizdir. Saray Mahallesi 205. Sokak No:4 06980 Kahramankazan / ANKARA - TÜRKİYE DRF-25 (Rev0 23/09/2019) 1/18

IES LM 79-08 DENEY RAPORU IES LM 79-08 TEST REPORTIES LM 79-08 TEST REPORT This report shall not be reproduced other than in full except with the permission of the laboratory.Testing

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: IES LM 79-08 DENEY RAPORU IES LM 79-08 TEST REPORTIES LM 79-08 TEST REPORT This report shall not be reproduced other than in full except with the permission of the laboratory.Testing

Trade Mark:

Döndü AYDIN

Test Mühendisi

(Test Engineer)

Test Yapan Personel ( ad, unvan):

Tested by (name, function / signature)

IES LM 79-08 DENEY RAPORU

IES LM 79-08 TEST REPORT

İmza:

Rapor Yayım Tarihi:

BAYTAŞ AYDINLATMA

Ahi Evran Mah. 225. Cad. No:84 Sincan / ANKARA

23.07.2020

23.07.2020

Customer name/address

Müşteri Logosu/Markası:

Date of test

Turkish Accreditation Agency (TURKAK) is a signatory to the European co-operation for Accreditation (EA) Multilateral Agreement (MLA) and to the

International Laboratory Accreditation Cooperation (ILAC) Mutual Recognition Arrangement (MRA) for the recognition of test reports

The date of receipt of test item

Sample No.:

Deneyin yapıldığı tarih :

Report approval date

Number of pages of the Report

Deney Raporunu Onaylayan Personel (ad, unvan):

Approved by (name, function / signature)

18

S20T6/0721/064+008-01/01-01/N01

Fatih KARA

Laboratuvar Müdürü

(Laboratory Manager)

Türk Akreditasyon Kurumu(TÜRKAK) deney raporlarının tanınırlığı konusunda Avrupa Akreditasyon Birliği(EA) ile Çok Taraflı Anlaşma ve Uluslararası

Laboratuvar Akreditasyon Birliği(ILAC) ile karşılıklı tanıma anlaşması imzalamıştır.

Rapor onay tarihi:

Raporun sayfa sayısı :

23.07.2020

Numune Numarası :

Numunenin kabul tarihi :

Report release date

BAYLED COSMO-24W-4K-70CRI-Zemine Gömme Aydınlatma Armatürü

BAYLED COSMO-24W-4K-70CRI-Floor Recessed Lighting Luminaire

23.07.2020

Numunenin adı ve tarifi :

Name and identity of test item

This report shall not be reproduced other than in full except with the permission of the laboratory.Testing reports without signature and seal are not valid.

İmza:

AB-0678-T

20T6064+008/

N0120/40

07-20

* İşaretli deneyler veya akreditasyon numarasının yer almadığı sayfalar, akreditasyon kapsamı dahilinde değildir. (Bkn: Test performans.)

(*signed tests or the papers which have not the accreditation number are not in the scope of accreditation. See: Tests performed)

(The test and/or measurement results, the uncertainties (if applicable) with confidence probability and test methods are given on the following pages which are

part of this report.)

Bu rapor; Laboratuvarımıza müşteri tarafından ulaşan numuneye deney ve/veya deneyler uygulanarak elde edilmiştir.

Numune Numarası kısmında belirtilen numune(ler) hariç, müşteriye ait diğer numuneleri kapsamaz.

(This report was prepared after applying test/tests to the sample that are sent to our laboratory by customer.)

(Except for the sample specified in the sample(s) number, note that this report does not involve other samples of the customer.)

Deney ve/veya ölçüm sonuçları, genişletilmiş ölçüm belirsizlikleri (olması halinde) ve deney metotları bu sertifikanın tamamlayıcı kısmı olan takip

eden sayfalarda verilmiştir.

Müşterinin adı/adresi :

Bu rapor laboratuvarın yazılı izni olmadan kısmen kopyalanıp çoğaltılamaz.İmzasız ve mühürsüz raporlar geçersizdir.

Saray Mahallesi 205. Sokak No:4

06980 Kahramankazan /

ANKARA - TÜRKİYE

DRF-25 (Rev0 23/09/2019) 1/18

Page 2: IES LM 79-08 DENEY RAPORU IES LM 79-08 TEST REPORTIES LM 79-08 TEST REPORT This report shall not be reproduced other than in full except with the permission of the laboratory.Testing

1 Dokümantasyon

(Documentation)

1.0 Deneyden Geçirilen Cihazın Özellikleri 3

(Equipment Under Test's)

1.1 DGC Bileşen Listesi 3

List Of Test Component

1.2 Ek Bilgi ve Sembollerin Tanımları 4

Ekstra Informatıon and Symbol Definitions

1.3 Deney Raporunda Kullanılan Sembollerin Tanımları ve Tanımlar 4

(Definition and Definations of Symbols Used in This Test Report )

1.4 Deney Standartları 5

(Test Standards)

1.5 Test Ekipman Listesi 5

(List of Test Equipment)

1.6 Deney Sonuçları ve Koşulları 6-12

(Test Results and Conditions)

3 Ekler

(Attachments)

3.1 DGC'nin Fotoğrafları 13

(Photos of EuT)

3.2 DGC'nin Bileşenlerinin Fotoğrafları 14-18

(Photos of Eut Components)

07-20

This report shall not be reproduced other than in full except with the permission of the laboratory.Testing reports without signature and seal are not valid.

Bu rapor laboratuvarın yazılı izni olmadan kısmen kopyalanıp çoğaltılamaz.İmzasız ve mühürsüz raporlar geçersizdir.

AB-0678-T20T6064+008/N0

120/40

İÇİNDEKİLER

(Contents)

Sayfa

(Page)

IES LM 79-08 DENEY RAPORU

IES LM 79-08 TEST REPORTSaray Mahallesi 205. Sokak

No:4 06980 Kahramankazan /

ANKARA - TÜRKİYE

DRF-25 (Rev0 23/09/2019) 2/18

Page 3: IES LM 79-08 DENEY RAPORU IES LM 79-08 TEST REPORTIES LM 79-08 TEST REPORT This report shall not be reproduced other than in full except with the permission of the laboratory.Testing

AB-0678-T

20T6064+008/N

0120/40

07-20

LED Rakor

Gland

Tablo 1.0 ve Tablo 1.1'de ki gereklilikler Müşteri tarafından sağlanmıştır.

The requirements in table 1.0 and table 1.1 are provided by the customer.

IES LM 79-08 DENEY RAPORU

IES LM 79-08 TEST REPORT

1.1 DGC Bileşen Listesi

SINIF I

CLASS I

Zemine Gömme Aydınlatma Armatürü

Floor Recessed Lighting Luminaire

Sınıf

1.0 DENEYDEN GEÇİRİLEN CİHAZIN ÖZELLİKLERİ

(Class)

(Light Source)

Gerilim/Frekansı

(Ratings)

(Equipment Under Test's)TABLO 1.0

(TABLE 1.0)

Model

TABLO 1.1

(TABLE 1.1)

LUMILEDS ORTAÇ

2D 6V L-LMIL130-

4070003000X21-

R5DG 4000K

M12x1,5

Markası

(Brand)

PCB

Electromechanical Switch

BAYLED

BAYLED COSMO-24W-4K

LUMILEDS MIDPOWER LED

2D 6V L-LMIL130-4070003000X21-R5DG 4000K

170-240 VAC / 50-60 Hz

Bu rapor laboratuvarın yazılı izni olmadan kısmen kopyalanıp çoğaltılamaz.İmzasız ve mühürsüz raporlar geçersizdir.

This report shall not be reproduced other than in full except with the permission of the laboratory.Testing reports without signature and seal are not valid.

(Model)

Sertifika

(Certificate)

DGC Adı

(EUT Name)

Tür/Model

(Type)

Işık Kaynağı

List Of Test Component

Kullanılan Bileşen

(Using Component)

Sürücü

Driver

MEAN WELL

APC-25-350

-

TLS-316-10R00127NC-18

Saray Mahallesi 205. Sokak No:4

06980 Kahramankazan /

ANKARA - TÜRKİYE

DRF-25 (Rev0 23/09/2019) 3/18

Page 4: IES LM 79-08 DENEY RAPORU IES LM 79-08 TEST REPORTIES LM 79-08 TEST REPORT This report shall not be reproduced other than in full except with the permission of the laboratory.Testing

- İşaretli kutu, deney raporunda kullanılan standartları gösterir.

(The marked box indicates that the listed standards are applicable for this report.)

- Boş kutu, deney raporunda kullanılmayan cihaz, standart ve koşulları gösterir.

(*Uygulanabilir/gerekli olduğunda doldurulacak)(* Applicable / to be completed when necessary)

-

-

20T6064+008/N0120/40 No'lu IESNA LM79-08 Deney Raporu; sayfa 13 ile 18

arası fotoğrafları yer alan numune için geçerlidir.

IESNA LM79-08 Test Report No 20T6064+008/N0120/40; Valid for the sample

from page 13 of 18.

IES LM 79-08 DENEY RAPORU

IES LM 79-08 TEST REPORT

* Feragat beyanı/ Disclaimer:

Bu rapor laboratuvarın yazılı izni olmadan kısmen kopyalanıp çoğaltılamaz.İmzasız ve mühürsüz raporlar geçersizdir.

This report shall not be reproduced other than in full except with the permission of the laboratory.Testing reports without signature and seal are not valid.

AB-0678-T20T6064+008/N0

120/40

07-20

Mahfaza- DGC'nin deneye tabi tutulan kısmı

(Enclosure- Applied part of the EUT )

1.2 EK BİLGİ

(EUT-Equipment under test)

*Sonuçların teslim alınan numune için geçerli olduğuna dair beyan/

Statement that the results are valid for the sample received:

*Karar kuralının açık tanımı/Definition of Decision Rule:

DGC - Deneyden geçen cihaz

(Definition and Definations of Symbols Used in This Test Report )

(The empty square indicates that the listed standards are not applicable for this report.)

1.3 DENEY RAPORUNDA KULLANILAN SEMBOLLERİN TANIMLARI VE TANIMLAR

Saray Mahallesi 205. Sokak No:4

06980 Kahramankazan /

ANKARA - TÜRKİYE

DRF-25 (Rev0 23/09/2019) 4/18

Page 5: IES LM 79-08 DENEY RAPORU IES LM 79-08 TEST REPORTIES LM 79-08 TEST REPORT This report shall not be reproduced other than in full except with the permission of the laboratory.Testing

İlgili Standart(lar)

related standart(s)

IES LM79-08

AB-0678-T

20T6064+008/N0120/

40

07-20

IES LM 79-08 DENEY RAPORU

IES LM 79-08 TEST REPORT

1.5 Test Ekipman Listesi

(List of Test Equipment)

Bu rapor laboratuvarın yazılı izni olmadan kısmen kopyalanıp çoğaltılamaz.İmzasız ve mühürsüz raporlar geçersizdir.

This report shall not be reproduced other than in full except with the permission of the laboratory.Testing reports without signature and seal are not valid.

Kalibrasyon / Doğrulama Tarihi

2 02-ELK YOKOGAWA

4 02-OPT SENSING

Sıra

(No)

Cihaz Adı Markası

(Equipment Name) (Brand Name)

3 01-OPT SENSING GMS-2000

1 01-ELK YOKOGAWA 91JA18655

2.05.2019

1.4 Deney Standartları

(Test Standards)

(Calib. / Correction Date)

Seri No

(Serial Number)

14.05.2019

14.05.2019

2016

SL-300

5 15-ELK GWINSTEK GEQ142209

2016

91KC26654

Saray Mahallesi 205. Sokak No:4

06980 Kahramankazan /

ANKARA - TÜRKİYE

DRF-25 (Rev0 23/09/2019) 5/18

Page 6: IES LM 79-08 DENEY RAPORU IES LM 79-08 TEST REPORTIES LM 79-08 TEST REPORT This report shall not be reproduced other than in full except with the permission of the laboratory.Testing

1.6 DENEY SONUÇLARI

AB-0678-T

20T6064+008/N0120/40

07-20

IES LM 79-08 DENEY RAPORU

IES LM 79-08 TEST REPORT

TEST RESULTS and CONDITIONS

Ölçülen Güç24.020 W

(Measured Power)

Işık Kaynağı LUMILEDS MIDPOWER LED

2D 6V L-LMIL130-4070003000X21-R5DG 4000K(Light Source)

Işık Akısı2676.12 lm

(Luminous FLux)

Etkinlik Faktörü111.41 lm/W

(Efficiency Factor )

Maksimum şiddet açısıC=270.0 γ=0.0

Angle Of Maximum Intensity

1.7 ORTAM ŞARTLARI ve KOŞULLARI

Işık Çıkış Oranı [C0 180]Left=11.2 Right=11.2

[C90 270]Left=11.2 Right=11.2(Light Output Ratio)

Maksimum Işık Şiddeti11097.720 cd

(Maximum Luminous Intensity)

Işık Çıkış Açısı22.22º

(Light Beam Angle)

Bu rapor laboratuvarın yazılı izni olmadan kısmen kopyalanıp çoğaltılamaz.İmzasız ve mühürsüz raporlar geçersizdir.

This report shall not be reproduced other than in full except with the permission of the laboratory.Testing reports without signature and seal are not valid.

Akım 0.245 A

Current

Hava Akş.

Deney Sonucunun Özeti/ Dip Not:

Summary of testing result / Foot note:

-

Sıcaklık 24,8ºC

Temperature

0 m/sAir Mvmt.

Gerilim220.090 VAC

Voltage

Nem%34,8Rh

Humidity

Saray Mahallesi 205.

Sokak No:4 06980

Kahramankazan /

ANKARA - TÜRKİYE

DRF-25 (Rev0 23/09/2019) 6/18

Page 7: IES LM 79-08 DENEY RAPORU IES LM 79-08 TEST REPORTIES LM 79-08 TEST REPORT This report shall not be reproduced other than in full except with the permission of the laboratory.Testing

AB-0678-T

20T6064+008/N0120/40

07-20

IES LM 79-08 DENEY RAPORU

IES LM 79-08 TEST REPORT

This report shall not be reproduced other than in full except with the permission of the laboratory.Testing reports without signature and seal are not valid.

Bu rapor laboratuvarın yazılı izni olmadan kısmen kopyalanıp çoğaltılamaz.İmzasız ve mühürsüz raporlar geçersizdir.

TEST RESULTS and CONDITIONS

1.6 DENEY SONUÇLARI

Saray Mahallesi 205.

Sokak No:4 06980

Kahramankazan /

ANKARA - TÜRKİYE

DRF-25 (Rev0 23/09/2019) 7/18

Page 8: IES LM 79-08 DENEY RAPORU IES LM 79-08 TEST REPORTIES LM 79-08 TEST REPORT This report shall not be reproduced other than in full except with the permission of the laboratory.Testing

TEST RESULTS and CONDITIONS

Bu rapor laboratuvarın yazılı izni olmadan kısmen kopyalanıp çoğaltılamaz.İmzasız ve mühürsüz raporlar geçersizdir.

This report shall not be reproduced other than in full except with the permission of the laboratory.Testing reports without signature and seal are not valid.

IES LM 79-08 DENEY RAPORU

IES LM 79-08 TEST REPORT

AB-0678-T

20T6064+008/N0120/40

07-20

1.6 DENEY SONUÇLARI

Saray Mahallesi 205.

Sokak No:4 06980

Kahramankazan /

ANKARA - TÜRKİYE

DRF-25 (Rev0 23/09/2019) 8/18

Page 9: IES LM 79-08 DENEY RAPORU IES LM 79-08 TEST REPORTIES LM 79-08 TEST REPORT This report shall not be reproduced other than in full except with the permission of the laboratory.Testing

TEST RESULTS and CONDITIONS

Bu rapor laboratuvarın yazılı izni olmadan kısmen kopyalanıp çoğaltılamaz.İmzasız ve mühürsüz raporlar geçersizdir.

This report shall not be reproduced other than in full except with the permission of the laboratory.Testing reports without signature and seal are not valid.

IES LM 79-08 DENEY RAPORU

IES LM 79-08 TEST REPORT

AB-0678-T

20T6064+008/N0120/40

07-20

1.6 DENEY SONUÇLARI

Saray Mahallesi 205.

Sokak No:4 06980

Kahramankazan /

ANKARA - TÜRKİYE

DRF-25 (Rev0 23/09/2019) 9/18

Page 10: IES LM 79-08 DENEY RAPORU IES LM 79-08 TEST REPORTIES LM 79-08 TEST REPORT This report shall not be reproduced other than in full except with the permission of the laboratory.Testing

TEST RESULTS and CONDITIONS

Bu rapor laboratuvarın yazılı izni olmadan kısmen kopyalanıp çoğaltılamaz.İmzasız ve mühürsüz raporlar geçersizdir.

This report shall not be reproduced other than in full except with the permission of the laboratory.Testing reports without signature and seal are not valid.

IES LM 79-08 DENEY RAPORU

IES LM 79-08 TEST REPORT

AB-0678-T

20T6064+008/N0120/40

07-20

1.6 DENEY SONUÇLARI

Saray Mahallesi 205.

Sokak No:4 06980

Kahramankazan /

ANKARA - TÜRKİYE

DRF-25 (Rev0 23/09/2019) 10/18

Page 11: IES LM 79-08 DENEY RAPORU IES LM 79-08 TEST REPORTIES LM 79-08 TEST REPORT This report shall not be reproduced other than in full except with the permission of the laboratory.Testing

(Measured Power)

Işık Akısı

TEST RESULTS and CONDITIONS

Ölçülen Güç

AB-0678-T20T6064+008/N0120

/40

07-20

1.6 DENEY SONUÇLARI

24.020 W

2676.12 lm

IES LM 79-08 DENEY RAPORU

IES LM 79-08 TEST REPORT

Armatürün Etkinlik Faktörü

(Efficacy Factor)

(Luminous FLux)

Güç Faktörü

(Power Factor)

İlişkilendirilmiş Renk Sıcaklığı

(Correlated Color Temp.)

Renksel Geriverim İndisi

(Colour Rendering Index)

Baskın Dalgaboyu

(Dominating Wavelenght)

Nem%34,8Rh

Humidity

1.7 ORTAM ŞARTLARI ve KOŞULLARI

Sıcaklık 24,8ºC

Temperature

Bu rapor laboratuvarın yazılı izni olmadan kısmen kopyalanıp çoğaltılamaz.İmzasız ve mühürsüz raporlar geçersizdir.

This report shall not be reproduced other than in full except with the permission of the laboratory.Testing reports without signature and seal are not valid.

Hava Akş. 0 m/s

Air Mvmt.

Akım 0.245A

(Current)

Deney Sonucunun Özeti/ Dip Not:

Summary of testing result / Foot note:

-

0.445

111.41 lm/W

22.22º

73 Ra

3967 K

Saray Mahallesi 205.

Sokak No:4 06980

Kahramankazan /

ANKARA - TÜRKİYE

DRF-25 (Rev0 23/09/2019) 11/18

Page 12: IES LM 79-08 DENEY RAPORU IES LM 79-08 TEST REPORTIES LM 79-08 TEST REPORT This report shall not be reproduced other than in full except with the permission of the laboratory.Testing

TEST RESULTS and CONDITIONS

Bu rapor laboratuvarın yazılı izni olmadan kısmen kopyalanıp çoğaltılamaz.İmzasız ve mühürsüz raporlar geçersizdir.

This report shall not be reproduced other than in full except with the permission of the laboratory.Testing reports without signature and seal are not valid.

IES LM 79-08 DENEY RAPORU

IES LM 79-08 TEST REPORT

AB-0678-T

20T6064+008/N0120/40

07-20

1.6 DENEY SONUÇLARI

Saray Mahallesi 205.

Sokak No:4 06980

Kahramankazan /

ANKARA - TÜRKİYE

DRF-25 (Rev0 23/09/2019) 12/18

Page 13: IES LM 79-08 DENEY RAPORU IES LM 79-08 TEST REPORTIES LM 79-08 TEST REPORT This report shall not be reproduced other than in full except with the permission of the laboratory.Testing

Ön/Front

Yan/Side

Arka/Back

İç tarafı/Interior

Bileşenleri/Component

Mahfaza/Enclosure

Ön/Front

Yan/Side

Arka/Back

İç tarafı/Interior

Bileşenleri/Component

Mahfaza/Enclosure

This report shall not be reproduced other than in full except with the permission of the laboratory.Testing reports without signature and seal are not valid.

Bu rapor laboratuvarın yazılı izni olmadan kısmen kopyalanıp çoğaltılamaz.İmzasız ve mühürsüz raporlar geçersizdir.

Markalama/Marking

plate

Markalama/Marking

plate

3.1 DGC'nin Fotoğrafları

(Photos of EUT)

AB-0678-T20T6064+008/N01

20/40

07-20

IES LM 79-08 DENEY RAPORU

IES LM 79-08 TEST REPORTSaray Mahallesi 205.

Sokak No:4 06980

Kahramankazan /

ANKARA - TÜRKİYE

DRF-25 (Rev0 23/09/2019) 13/18

Page 14: IES LM 79-08 DENEY RAPORU IES LM 79-08 TEST REPORTIES LM 79-08 TEST REPORT This report shall not be reproduced other than in full except with the permission of the laboratory.Testing

Ön/Front

Yan/Side

Arka/Back

İç tarafı/Interior

Bileşenleri/Component

Mahfaza/Enclosure

Ön/Front

Yan/Side

Arka/Back

İç tarafı/Interior

Bileşenleri/Component

Mahfaza/Enclosure

AB-0678-T

20T6064+008/N0120/40

07-20

3.1 DGC'nin Fotoğrafları

(Photos of EUT)

Markalama/Marking plate

IES LM 79-08 DENEY RAPORU

IES LM 79-08 TEST REPORT

Bu rapor laboratuvarın yazılı izni olmadan kısmen kopyalanıp çoğaltılamaz.İmzasız ve mühürsüz raporlar geçersizdir.

This report shall not be reproduced other than in full except with the permission of the laboratory.Testing reports without signature and seal are not valid.

Markalama/Marking plate

Saray Mahallesi 205. Sokak

No:4 06980

Kahramankazan / ANKARA

- TÜRKİYE

DRF-25 (Rev0 23/09/2019) 14/18

Page 15: IES LM 79-08 DENEY RAPORU IES LM 79-08 TEST REPORTIES LM 79-08 TEST REPORT This report shall not be reproduced other than in full except with the permission of the laboratory.Testing

Ön/Front

Yan/Side

Arka/Back

İç tarafı/Interior

Bileşenleri/Component

Mahfaza/Enclosure

Ön/Front

Yan/Side

Arka/Back

İç tarafı/Interior

Bileşenleri/Component

Mahfaza/Enclosure

AB-0678-T

20T6064+008/N012

0/40

07-20

Markalama/Marking

plate

IES LM 79-08 DENEY RAPORU

IES LM 79-08 TEST REPORT

Bu rapor laboratuvarın yazılı izni olmadan kısmen kopyalanıp çoğaltılamaz.İmzasız ve mühürsüz raporlar geçersizdir.

This report shall not be reproduced other than in full except with the permission of the laboratory.Testing reports without signature and seal are not valid.

3.2 DGC'nin Bileşenlerinin Fotoğrafları

(Photos of Eut Components)

Markalama/Marking

plate

Saray Mahallesi 205. Sokak No:4

06980 Kahramankazan / ANKARA -

TÜRKİYE

DRF-25 (Rev0 23/09/2019) 15/18

Page 16: IES LM 79-08 DENEY RAPORU IES LM 79-08 TEST REPORTIES LM 79-08 TEST REPORT This report shall not be reproduced other than in full except with the permission of the laboratory.Testing

Ön/Front

Yan/Side

Arka/Back

İç tarafı/Interior

Bileşenleri/Component

Mahfaza/Enclosure

Ön/Front

Yan/Side

Arka/Back

İç tarafı/Interior

Bileşenleri/Component

Mahfaza/Enclosure

Bu rapor laboratuvarın yazılı izni olmadan kısmen kopyalanıp çoğaltılamaz.İmzasız ve mühürsüz raporlar geçersizdir.

This report shall not be reproduced other than in full except with the permission of the laboratory.Testing reports without signature and seal are not valid.

3.2 DGC'nin Bileşenlerinin Fotoğrafları

IES LM 79-08 DENEY RAPORU

IES LM 79-08 TEST REPORT

AB-0678-T

20T6064+008/N012

0/40

07-20

(Photos of Eut Components)

Markalama/Marking

plate

Markalama/Marking

plate

Saray Mahallesi 205. Sokak No:4

06980 Kahramankazan / ANKARA -

TÜRKİYE

DRF-25 (Rev0 23/09/2019) 16/18

Page 17: IES LM 79-08 DENEY RAPORU IES LM 79-08 TEST REPORTIES LM 79-08 TEST REPORT This report shall not be reproduced other than in full except with the permission of the laboratory.Testing

Ön/Front

Yan/Side

Arka/Back

İç tarafı/Interior

Bileşenleri/Component

Mahfaza/Enclosure

Ön/Front

Yan/Side

Arka/Back

İç tarafı/Interior

Bileşenleri/Component

Mahfaza/Enclosure

3.2 DGC'nin Bileşenlerinin Fotoğrafları

Bu rapor laboratuvarın yazılı izni olmadan kısmen kopyalanıp çoğaltılamaz.İmzasız ve mühürsüz raporlar geçersizdir.

This report shall not be reproduced other than in full except with the permission of the laboratory.Testing reports without signature and seal are not valid.

IES LM 79-08 DENEY RAPORU

IES LM 79-08 TEST REPORT

AB-0678-T

20T6064+008/N012

0/40

07-20

(Photos of Eut Components)

Markalama/Marking

plate

Markalama/Marking

plate

Saray Mahallesi 205. Sokak No:4

06980 Kahramankazan / ANKARA -

TÜRKİYE

DRF-25 (Rev0 23/09/2019) 17/18

Page 18: IES LM 79-08 DENEY RAPORU IES LM 79-08 TEST REPORTIES LM 79-08 TEST REPORT This report shall not be reproduced other than in full except with the permission of the laboratory.Testing

Ön/Front

Yan/Side

Arka/Back

İç tarafı/Interior

Bileşenleri/Component

Mahfaza/Enclosure

Ön/Front

Yan/Side

Arka/Back

İç tarafı/Interior

Bileşenleri/Component

Mahfaza/Enclosure

3.2 DGC'nin Bileşenlerinin Fotoğrafları

IES LM 79-08 DENEY RAPORU

IES LM 79-08 TEST REPORT

AB-0678-T

20T6064+008/N012

0/40

07-20

Bu rapor laboratuvarın yazılı izni olmadan kısmen kopyalanıp çoğaltılamaz.İmzasız ve mühürsüz raporlar geçersizdir.

This report shall not be reproduced other than in full except with the permission of the laboratory.Testing reports without signature and seal are not valid.

(Photos of Eut Components)

Markalama/Marking

plate

Markalama/Marking

plate

Saray Mahallesi 205. Sokak No:4

06980 Kahramankazan / ANKARA -

TÜRKİYE

DRF-25 (Rev0 23/09/2019) 18/18