If Cable Termination, Earthing & Water Proofing

Embed Size (px)

Citation preview

  • 7/30/2019 If Cable Termination, Earthing & Water Proofing

    1/26

    IF Cable Termination, Earthing & Water Proofing

  • 7/30/2019 If Cable Termination, Earthing & Water Proofing

    2/26

    Table of Contents

    1. IF Cable Grounding

    1.1 Material and Tools1.2 Grounding Kit

    1.3 Grounding Cable Termination

    1.4 Waterproofing of Grounding Cable

    2. IF Cable Termination

    2.1 IF Cable Termination with N-Type Connector

    2.2 N-Type Connector Installation Procedure

    2.3 Waterproofing of IF Cable ODU End

    3. Surge Arrestor Installation

    3.1 Surge Arrestor Installation Guide

    3.2 Grounding of Surge Arrestor

    3.3 Waterproofing of Coaxial Cable Termination

  • 7/30/2019 If Cable Termination, Earthing & Water Proofing

    3/26

    1. IF Cable Grounding

    1.1 Material and Tools for IF Cable Grounding

    1.1.1 Material

    Grounding Kit

    Thimble

    Self bonding Tape

    PVC Protection Tape

    1.1.2. Tools

    Knife

    Cable Cutter

    Measure/Ruler

    Adjustable Wrench

    Hand Crimping Tool

  • 7/30/2019 If Cable Termination, Earthing & Water Proofing

    4/26

    1.2 Grounding Kit

    Earthing Cable of 6mm

    Fixing spring clampThimble

    Earthing Connector

  • 7/30/2019 If Cable Termination, Earthing & Water Proofing

    5/26

    1.3 Grounding Cable Termination (1/4)

    Step.1 Mark on the cable for the size of Earthing Connector

  • 7/30/2019 If Cable Termination, Earthing & Water Proofing

    6/26

    1.3 Grounding Cable Termination (2/4)

    Step.2Cut & remove the sheath of IF cable, be sure not to damage the braided shield

    Step.1

    Step.2

    Step.3

    Step.4

  • 7/30/2019 If Cable Termination, Earthing & Water Proofing

    7/26

    1.3 Grounding Cable Termination (3/4)

    Step.3 Place and fix the Earthing connector on the IF cable as shown in pictures

    Fixing spring clamp on Earthing ConnectorEarthing Connector on IF cable

  • 7/30/2019 If Cable Termination, Earthing & Water Proofing

    8/26

    1.3 Grounding Cable Termination (4/4)

    Step.1

    Step.2

    Earth Bus bar at Horizontal cable tray

    Earth Bus bar at Vertical cable tray

    Step.4 Crimp the thimble with crimping tool and terminate at Earth Bus bar

  • 7/30/2019 If Cable Termination, Earthing & Water Proofing

    9/26

    1.4 Waterproofing of Grounding Cable part (1/3)Many times water penetration inside the IF Cable from the Grounding point, resulting in moisture,

    was observed on Straight Connector and Surge Arrester part (water accumulated in the horizontal

    cable portion). To overcome this; set Spring Clamp for firm fixing with grounding kit. It moves when

    the spring clamp is not tightened. As a result, the waterproof taped part moves and a crack is built.

    Moistures penetrates from Grounding cable crack and accumulate at free space of connector point.

    The one which has possibility of moisture penetration is because of wrong point sealing, not sealed

    Grounding cable crack with silicon paste (silicon rubber) or not sealed with proper thickness of self-

    bonding tape.

    Cracks to be sealed

    with silicon paste

    Self-bonding

    Tape (>2mm)cracks to be

    sealed

    1 Point seals step

    Spring Clamp for fixing

    Seals of cable crack with silicon paste (silicon rubber) and then total shielding

    with self-bonding tape (more than 3mm thickness).

    3

    Protective Taping (>3 layer), with PVC tape.

    The direction of the winding always ends on the side of ODU/ANT or

    upper to prevent the infiltration of water.

    4

    2 Shielding of cable connection part. All naked uneven metal to be shield(wraps) with self-bonding tape, without IF cable.

  • 7/30/2019 If Cable Termination, Earthing & Water Proofing

    10/26

    1.4 Waterproofing of Grounding Cable (2/3)

    Step 1. Apply the self bonding tape to fill the cracks on ends of Earthing kit for leveling

    Self bonding tape more than 3mm thickness

    Step 2. Apply more than 3mm thickness self bonding tape for Shielding of all naked uneven metal,

    and shield the cable cracks with silicon paste .

    Self bonding tape to fill the cracks

    Step1

    Step2

    Note: Crack between cables should be shielded with silicon paste before taping

  • 7/30/2019 If Cable Termination, Earthing & Water Proofing

    11/26

    1.4 Waterproofing of Grounding Cable (3/3)

    Step 4. Use 100 mm black Tie wrap to tie the both ends of Earthing kit after applying the PVC tape

    PVC Protection Tape

    Step 3. Apply 3 layers of PVC Protection Tape

    Tie Wrap at both ends

    Note: Finish taping from bottom to ODU/ANT side or upper side

  • 7/30/2019 If Cable Termination, Earthing & Water Proofing

    12/26

    2.1 IF Cable Termination with N-Type Connector

    Parts of N-Type Connector (Straight) shown in below.

    1. Lock Nut

    2. Washer

    3.Gasket

    4.Clamp A

    5.Clamp B

    7.Insulation

    8.Connector Shell

    1 2 3 4 5 76 8

    6.Center Contact Pin

    2. IF Cable Termination

  • 7/30/2019 If Cable Termination, Earthing & Water Proofing

    13/26

    2.2 N-Type Connector Installation Procedure (1/6)

    Step 1. first fit the lock nut, washer and gasket on the cable as shown

    Lock Nut

    Washer

    Gasket (Rubber)

  • 7/30/2019 If Cable Termination, Earthing & Water Proofing

    14/26

    2.2 N-Type Connector Installation Procedure (2/6)

    Step 2. Strip back the cable sheath, taking care not to damage the braided shield, and fit the

    clamp A

    Step 3. Fold back the braided shield (separating the strands of braid) and trim it

    Step.2 Step.3-1 Step.3-2

    Clamp A

  • 7/30/2019 If Cable Termination, Earthing & Water Proofing

    15/26

    2.2 N-Type Connector Installation Procedure (3/6)

    Step 4. Cut away the insulation from the center conductor and fit the clamp B. Be sure

    not to cut or scratch the conductor while striping the insulation.

    Clamp B

    Step.4 -1

    Step.4

  • 7/30/2019 If Cable Termination, Earthing & Water Proofing

    16/26

    2.2 N-Type Connector Installation Procedure (4/6)

    Step 5. Cut the center conductor. Taper the end of the conductor using file as shown in the circle

    Step 6.Mount the center contact pin onto the center conductor as shown

  • 7/30/2019 If Cable Termination, Earthing & Water Proofing

    17/26

    2.2 N-Type Connector Installation Procedure (5/6)

    Insulation

    Step 7. Mount the insulation onto the center contact

    Step.7

  • 7/30/2019 If Cable Termination, Earthing & Water Proofing

    18/26

    2.2 N-Type Connector Installation Procedure (6/6)

    Step 8. Insert the cable into the connector shell

    Step 9. Tighten the lock nut

    Step.8

    Step.9

    Note: Never turn the connector shell

  • 7/30/2019 If Cable Termination, Earthing & Water Proofing

    19/26

    2.3 Waterproofing of IF Cable at ODU End

    Step 1. Connect IF cable with ODU and tight properly.

    Step 3. Apply more than 3mm thickness of self bonding tape by stretching its each turn.

    Step 4. Apply three or more layers of PVC protection tape by over lapping its each turn.

    Self bonding tape >3mm thickness Three or more layers of PVC tape

    Step 5. Use 100mm black tie wrap to tie the both ends after applying PVC tape on connector.

    Step 2. Apply self bonding tape on moving parts of connector to seal the cracks.

    Note: 1. Wrapping of tape should be finished at ODU end

    2. IF cable should turned down ward direction

  • 7/30/2019 If Cable Termination, Earthing & Water Proofing

    20/26

    3.1 Surge Arrestor Installation

    GuideInsert the surge arrestor and NJ-NJ adapter in between both NP-Type connectors as shown infollowing picture.

    N-Type connector N-Type connectorNJ-NJ Adapter

    Surge arrester

    Surge arrestor grounding thimble

    3. Surge Arrestor Installation Guide

  • 7/30/2019 If Cable Termination, Earthing & Water Proofing

    21/26

    3.2 Grounding of Surge Arrestor

    Step 1. Connect grounding thimble to the surge arrester as shown in picture.

    Step 2. Do proper water proofing and labeling.

    Step 3. Connect the grounding cable with earth bus bar.

    Surge arrester grounding Surge arrester weatherproofing Grounding cables at Bus bar

    Step 3

    Step1 Step2

    3 3 Waterproofing of Coa ial Cable Termination (1/5) R 13/J l/08 (Y D)

  • 7/30/2019 If Cable Termination, Earthing & Water Proofing

    22/26

    3.3 Waterproofing of Coaxial Cable Termination (1/5) Rev. 13/Jul/08 (Y.D)

    Point seals and leveling: Use Self-Bonding (adhesion) rubber tape, pull it (stretch) until becomes thin and then

    wrapping on the crack point. (stretch or expand self-bonding tape to max (800% Scapa).

    1stStep

    Cracks to be sealed Seals packing for cable fixing.

    The vibration of the cable always

    breaks this packing and shield

    wires of coaxial cable.

    Water

    infiltration

    Water

    infiltration

    SURGE ARRESTORCOAXIAL

    TERMINATION

    COAXIAL

    TERMINATION

    No water proofing points

    (cracks of moving parts)

    2nd Step Shielding of cable connection point: 1) Shield with self bonding tape (>3mm thickness).

    2) Connect grounding cable to arrestor body.3) suppresses4) Silicon seals

    3 3 Waterproofing of Coaxial Cable Termination (2/5)

  • 7/30/2019 If Cable Termination, Earthing & Water Proofing

    23/26

    Use a PVC protection tape, It pulls at 1st laying for fastens up the self-bonding (autohesion) layer.

    Overlap the PVC tape to half width. 2nd to 3rd laying, it does usual wrapping method.

    The direction of the winding always ends on the side of ODU/ANT (up) to prevent the

    infiltration of water.

    Never use Vinyl insulating tape !!. The tape which has a elasticity (soft) can not use.The PVC protection tape has only a few stretch margin and it has high resistance for outdoor use

    (compared with the usual vinyl insulation tape).

    4th Step Protective Taping (3 layer) Cable tie

    ODU/ANT (up) side

    The rubber fusion layer >3mm thickness

    3rdStep Total Shielding: Use Self-Bonding Tape, It pulls (stretch >100%) tape to ensure effective

    bonding (fusion, adhesion) and then wrap until sufficient thickness (>3mm).

    First use a silicon seals for grounding cable to seals this cable crack.

    Shield with self bonding tape (more than 3mm thickness)ODU/ANT up-side

    3.3 Waterproofing of Coaxial Cable Termination (2/5)

  • 7/30/2019 If Cable Termination, Earthing & Water Proofing

    24/26

    3.4 Surge Arrestor Waterproofing Guide (3/5)

    Step 2. Apply self bonding tape to moving parts of connector to seal the gap as shown in picture.

    Before filling the cracks with self bonding tape After sealing the cracks with self bonding tape

    Step 1. Remove the thimble from surge arrestor and terminate on the earth cable of 2.5mm.

    Step 3. Seal up the earth cable connection part (Thimble) gently.

    Step 4. Connect earth cable to surge arrestor body.

    Step 5. Suppress earthcable to connector body and IF cable.

    Step 6. Put silicon paste to seal the cracks between cables.

  • 7/30/2019 If Cable Termination, Earthing & Water Proofing

    25/26

    3.3 Surge Arrestor Waterproofing Guide (4/5)

    Step.7 Apply more than 3mm thickness of self bonding tape by stretching each turn of tape.

  • 7/30/2019 If Cable Termination, Earthing & Water Proofing

    26/26

    3.3 Surge Arrestor Waterproofing Guide (5/5)Step 8. Apply two or more layers of PVC protection tape by over lapping each turn of tape.

    Step 9. Use 100mm long black tie wrap to tie the both ends after applying PVC tape on

    connector.

    PVC Protection Tape Wrapping 100 mm Black ties on connector