7/30/2019 If Cable Termination, Earthing & Water Proofing
1/26
IF Cable Termination, Earthing & Water Proofing
7/30/2019 If Cable Termination, Earthing & Water Proofing
2/26
Table of Contents
1. IF Cable Grounding
1.1 Material and Tools1.2 Grounding Kit
1.3 Grounding Cable Termination
1.4 Waterproofing of Grounding Cable
2. IF Cable Termination
2.1 IF Cable Termination with N-Type Connector
2.2 N-Type Connector Installation Procedure
2.3 Waterproofing of IF Cable ODU End
3. Surge Arrestor Installation
3.1 Surge Arrestor Installation Guide
3.2 Grounding of Surge Arrestor
3.3 Waterproofing of Coaxial Cable Termination
7/30/2019 If Cable Termination, Earthing & Water Proofing
3/26
1. IF Cable Grounding
1.1 Material and Tools for IF Cable Grounding
1.1.1 Material
Grounding Kit
Thimble
Self bonding Tape
PVC Protection Tape
1.1.2. Tools
Knife
Cable Cutter
Measure/Ruler
Adjustable Wrench
Hand Crimping Tool
7/30/2019 If Cable Termination, Earthing & Water Proofing
4/26
1.2 Grounding Kit
Earthing Cable of 6mm
Fixing spring clampThimble
Earthing Connector
7/30/2019 If Cable Termination, Earthing & Water Proofing
5/26
1.3 Grounding Cable Termination (1/4)
Step.1 Mark on the cable for the size of Earthing Connector
7/30/2019 If Cable Termination, Earthing & Water Proofing
6/26
1.3 Grounding Cable Termination (2/4)
Step.2Cut & remove the sheath of IF cable, be sure not to damage the braided shield
Step.1
Step.2
Step.3
Step.4
7/30/2019 If Cable Termination, Earthing & Water Proofing
7/26
1.3 Grounding Cable Termination (3/4)
Step.3 Place and fix the Earthing connector on the IF cable as shown in pictures
Fixing spring clamp on Earthing ConnectorEarthing Connector on IF cable
7/30/2019 If Cable Termination, Earthing & Water Proofing
8/26
1.3 Grounding Cable Termination (4/4)
Step.1
Step.2
Earth Bus bar at Horizontal cable tray
Earth Bus bar at Vertical cable tray
Step.4 Crimp the thimble with crimping tool and terminate at Earth Bus bar
7/30/2019 If Cable Termination, Earthing & Water Proofing
9/26
1.4 Waterproofing of Grounding Cable part (1/3)Many times water penetration inside the IF Cable from the Grounding point, resulting in moisture,
was observed on Straight Connector and Surge Arrester part (water accumulated in the horizontal
cable portion). To overcome this; set Spring Clamp for firm fixing with grounding kit. It moves when
the spring clamp is not tightened. As a result, the waterproof taped part moves and a crack is built.
Moistures penetrates from Grounding cable crack and accumulate at free space of connector point.
The one which has possibility of moisture penetration is because of wrong point sealing, not sealed
Grounding cable crack with silicon paste (silicon rubber) or not sealed with proper thickness of self-
bonding tape.
Cracks to be sealed
with silicon paste
Self-bonding
Tape (>2mm)cracks to be
sealed
1 Point seals step
Spring Clamp for fixing
Seals of cable crack with silicon paste (silicon rubber) and then total shielding
with self-bonding tape (more than 3mm thickness).
3
Protective Taping (>3 layer), with PVC tape.
The direction of the winding always ends on the side of ODU/ANT or
upper to prevent the infiltration of water.
4
2 Shielding of cable connection part. All naked uneven metal to be shield(wraps) with self-bonding tape, without IF cable.
7/30/2019 If Cable Termination, Earthing & Water Proofing
10/26
1.4 Waterproofing of Grounding Cable (2/3)
Step 1. Apply the self bonding tape to fill the cracks on ends of Earthing kit for leveling
Self bonding tape more than 3mm thickness
Step 2. Apply more than 3mm thickness self bonding tape for Shielding of all naked uneven metal,
and shield the cable cracks with silicon paste .
Self bonding tape to fill the cracks
Step1
Step2
Note: Crack between cables should be shielded with silicon paste before taping
7/30/2019 If Cable Termination, Earthing & Water Proofing
11/26
1.4 Waterproofing of Grounding Cable (3/3)
Step 4. Use 100 mm black Tie wrap to tie the both ends of Earthing kit after applying the PVC tape
PVC Protection Tape
Step 3. Apply 3 layers of PVC Protection Tape
Tie Wrap at both ends
Note: Finish taping from bottom to ODU/ANT side or upper side
7/30/2019 If Cable Termination, Earthing & Water Proofing
12/26
2.1 IF Cable Termination with N-Type Connector
Parts of N-Type Connector (Straight) shown in below.
1. Lock Nut
2. Washer
3.Gasket
4.Clamp A
5.Clamp B
7.Insulation
8.Connector Shell
1 2 3 4 5 76 8
6.Center Contact Pin
2. IF Cable Termination
7/30/2019 If Cable Termination, Earthing & Water Proofing
13/26
2.2 N-Type Connector Installation Procedure (1/6)
Step 1. first fit the lock nut, washer and gasket on the cable as shown
Lock Nut
Washer
Gasket (Rubber)
7/30/2019 If Cable Termination, Earthing & Water Proofing
14/26
2.2 N-Type Connector Installation Procedure (2/6)
Step 2. Strip back the cable sheath, taking care not to damage the braided shield, and fit the
clamp A
Step 3. Fold back the braided shield (separating the strands of braid) and trim it
Step.2 Step.3-1 Step.3-2
Clamp A
7/30/2019 If Cable Termination, Earthing & Water Proofing
15/26
2.2 N-Type Connector Installation Procedure (3/6)
Step 4. Cut away the insulation from the center conductor and fit the clamp B. Be sure
not to cut or scratch the conductor while striping the insulation.
Clamp B
Step.4 -1
Step.4
7/30/2019 If Cable Termination, Earthing & Water Proofing
16/26
2.2 N-Type Connector Installation Procedure (4/6)
Step 5. Cut the center conductor. Taper the end of the conductor using file as shown in the circle
Step 6.Mount the center contact pin onto the center conductor as shown
7/30/2019 If Cable Termination, Earthing & Water Proofing
17/26
2.2 N-Type Connector Installation Procedure (5/6)
Insulation
Step 7. Mount the insulation onto the center contact
Step.7
7/30/2019 If Cable Termination, Earthing & Water Proofing
18/26
2.2 N-Type Connector Installation Procedure (6/6)
Step 8. Insert the cable into the connector shell
Step 9. Tighten the lock nut
Step.8
Step.9
Note: Never turn the connector shell
7/30/2019 If Cable Termination, Earthing & Water Proofing
19/26
2.3 Waterproofing of IF Cable at ODU End
Step 1. Connect IF cable with ODU and tight properly.
Step 3. Apply more than 3mm thickness of self bonding tape by stretching its each turn.
Step 4. Apply three or more layers of PVC protection tape by over lapping its each turn.
Self bonding tape >3mm thickness Three or more layers of PVC tape
Step 5. Use 100mm black tie wrap to tie the both ends after applying PVC tape on connector.
Step 2. Apply self bonding tape on moving parts of connector to seal the cracks.
Note: 1. Wrapping of tape should be finished at ODU end
2. IF cable should turned down ward direction
7/30/2019 If Cable Termination, Earthing & Water Proofing
20/26
3.1 Surge Arrestor Installation
GuideInsert the surge arrestor and NJ-NJ adapter in between both NP-Type connectors as shown infollowing picture.
N-Type connector N-Type connectorNJ-NJ Adapter
Surge arrester
Surge arrestor grounding thimble
3. Surge Arrestor Installation Guide
7/30/2019 If Cable Termination, Earthing & Water Proofing
21/26
3.2 Grounding of Surge Arrestor
Step 1. Connect grounding thimble to the surge arrester as shown in picture.
Step 2. Do proper water proofing and labeling.
Step 3. Connect the grounding cable with earth bus bar.
Surge arrester grounding Surge arrester weatherproofing Grounding cables at Bus bar
Step 3
Step1 Step2
3 3 Waterproofing of Coa ial Cable Termination (1/5) R 13/J l/08 (Y D)
7/30/2019 If Cable Termination, Earthing & Water Proofing
22/26
3.3 Waterproofing of Coaxial Cable Termination (1/5) Rev. 13/Jul/08 (Y.D)
Point seals and leveling: Use Self-Bonding (adhesion) rubber tape, pull it (stretch) until becomes thin and then
wrapping on the crack point. (stretch or expand self-bonding tape to max (800% Scapa).
1stStep
Cracks to be sealed Seals packing for cable fixing.
The vibration of the cable always
breaks this packing and shield
wires of coaxial cable.
Water
infiltration
Water
infiltration
SURGE ARRESTORCOAXIAL
TERMINATION
COAXIAL
TERMINATION
No water proofing points
(cracks of moving parts)
2nd Step Shielding of cable connection point: 1) Shield with self bonding tape (>3mm thickness).
2) Connect grounding cable to arrestor body.3) suppresses4) Silicon seals
3 3 Waterproofing of Coaxial Cable Termination (2/5)
7/30/2019 If Cable Termination, Earthing & Water Proofing
23/26
Use a PVC protection tape, It pulls at 1st laying for fastens up the self-bonding (autohesion) layer.
Overlap the PVC tape to half width. 2nd to 3rd laying, it does usual wrapping method.
The direction of the winding always ends on the side of ODU/ANT (up) to prevent the
infiltration of water.
Never use Vinyl insulating tape !!. The tape which has a elasticity (soft) can not use.The PVC protection tape has only a few stretch margin and it has high resistance for outdoor use
(compared with the usual vinyl insulation tape).
4th Step Protective Taping (3 layer) Cable tie
ODU/ANT (up) side
The rubber fusion layer >3mm thickness
3rdStep Total Shielding: Use Self-Bonding Tape, It pulls (stretch >100%) tape to ensure effective
bonding (fusion, adhesion) and then wrap until sufficient thickness (>3mm).
First use a silicon seals for grounding cable to seals this cable crack.
Shield with self bonding tape (more than 3mm thickness)ODU/ANT up-side
3.3 Waterproofing of Coaxial Cable Termination (2/5)
7/30/2019 If Cable Termination, Earthing & Water Proofing
24/26
3.4 Surge Arrestor Waterproofing Guide (3/5)
Step 2. Apply self bonding tape to moving parts of connector to seal the gap as shown in picture.
Before filling the cracks with self bonding tape After sealing the cracks with self bonding tape
Step 1. Remove the thimble from surge arrestor and terminate on the earth cable of 2.5mm.
Step 3. Seal up the earth cable connection part (Thimble) gently.
Step 4. Connect earth cable to surge arrestor body.
Step 5. Suppress earthcable to connector body and IF cable.
Step 6. Put silicon paste to seal the cracks between cables.
7/30/2019 If Cable Termination, Earthing & Water Proofing
25/26
3.3 Surge Arrestor Waterproofing Guide (4/5)
Step.7 Apply more than 3mm thickness of self bonding tape by stretching each turn of tape.
7/30/2019 If Cable Termination, Earthing & Water Proofing
26/26
3.3 Surge Arrestor Waterproofing Guide (5/5)Step 8. Apply two or more layers of PVC protection tape by over lapping each turn of tape.
Step 9. Use 100mm long black tie wrap to tie the both ends after applying PVC tape on
connector.
PVC Protection Tape Wrapping 100 mm Black ties on connector