Upload
anahi-morris
View
216
Download
0
Tags:
Embed Size (px)
Citation preview
Industrial Design 7T552
Assignment 1 – Column’s in Building
Rick van Veghel - 0719020 - BTJoost Klaasen - 0727802 - UTJoost van Ravesteijn - 0721974 - BT
23-02-2011
BegeleidersM.H.N. van den BergProf.Dr.Ir. J.J.N. Lichtenberg
Industrial Design – 7T552 - Rick van Veghel – Joost Klaasen - Joost van Ravensteijn- 23.02.2011
Index
Analyze existing column·
Other/extra functions·
Design of innovative column system
01
02
03
Industrial Design – 7T552 - Rick van Veghel – Joost Klaasen - Joost van Ravensteijn- 23.02.2011
Analyze existing column
01 02 03Analyze Existing Column
Function
- Structural element : Force remittance
- Aesthetic value
Industrial Design – 7T552 - Rick van Veghel – Joost Klaasen - Joost van Ravensteijn- 23.02.2011
Analyze existing column
01 02 03Analyze Existing Column
History
- timeline is not exactly determined- famous and old buildings have columns- more aesthetic value- columns had/have a large size
- as long as people are building columns are built
Industrial Design – 7T552 - Rick van Veghel – Joost Klaasen - Joost van Ravensteijn - 23.02.2011
Analyze existing column
01 02 03Analyze Existing Column
Materials
Steel
Iron steel
Masonry
Concrete
Timber
Industrial Design – 7T552 - Rick van Veghel – Joost Klaasen - Joost van Ravensteijn - 23.02.2011
Analyze existing column
01 02 03Analyze Existing Column
ProducedHistory: In work Nowadays: Prefab
Labour intensiveAccurate
Faster
Designed- Structural requirements - Aesthetic requirements
Industrial Design – 7T552 - Rick van Veghel – Joost Klaasen - Joost van Ravensteijn- 23.02.2011
Analyze existing column
01 02 03Analyze Existing Column
Subsystems- Compressive force- Buckling load- Stability
Interface/conect- Remittance of floor load down (Constant + Variable)- Remittance of the façade load (wind + own weight)
Industrial Design – 7T552 - Rick van Veghel – Joost Klaasen - Joost van Ravensteijn- 23.02.2011
Analyze existing column
01 02 03Analyze Existing Column
Advantages of columns in buildings
- Open structure- More gross floor area- Easy to fit different functions- More light invasion, compared with load-bearing walls
Disadvantages- Additional stability facilities necessary- If there is a closed façade, back padding needed
Industrial Design – 7T552 - Rick van Veghel – Joost Klaasen - Joost van Ravensteijn - 23.02.2011
Other/extra functions
01 02 03Other/extra functions
Secondary functions:- More Aesthetic- Removable / Flexible- Transit facilities (ventilation, rain water,
pipes, electricity)- Integration of sun protections- Generate energy/Heat generation
Industrial Design – 7T552 - Rick van Veghel – Joost Klaasen - Joost van Ravensteijn- 23.02.2011
Design of innovative column system
01 02 03Design of innovative column system
Variant 1
Industrial Design – 7T552 - Rick van Veghel – Joost Klaasen - Joost van Ravensteijn- 23.02.2011
Design of innovative column system
Variant 2
01 02 03Design of innovative column system
Industrial Design – 7T552 - Rick van Veghel – Joost Klaasen - Joost van Ravensteijn- 23.02.2011
Design of innovative column system
Variant 3
01 02 03Design of innovative column system
Industrial Design – 7T552 - Rick van Veghel – Joost Klaasen - Joost van Ravensteijn- 23.02.2011
Design of innovative column system
Final version
01 02 03Design of innovative column system