Injection issues overnight 10:50 Access QPS & EPC Vacuum leak SPS – magnet to be replaced…

Embed Size (px)

DESCRIPTION

15:42 Sector 81 tripped. QD threw fast power abort – cause unknown 16:20 Start pre-cycle 18:11 – injecting again 19:22 - fan fault on the power supply for RQT12.R5B2. Reset and go on. Problems loading collimator… Friday 16 th - afternoon 3

Citation preview

Page 1: Injection issues overnight 10:50 Access  QPS & EPC  Vacuum leak SPS – magnet to be replaced…

Injection issues overnight

10:50 Access QPS & EPC Vacuum leak SPS – magnet to be replaced Monday – cycling for

FT and LHC only over the weekend 12:15 Pre-cycle 14:16 discovered that RT trims were indeed in during the

previous fill and they are probably at the origin of the energy offset of this night.

Friday 16th July - Morning

1

Page 2: Injection issues overnight 10:50 Access  QPS & EPC  Vacuum leak SPS – magnet to be replaced…

RT funny

2

Page 3: Injection issues overnight 10:50 Access  QPS & EPC  Vacuum leak SPS – magnet to be replaced…

15:42 Sector 81 tripped. QD threw fast power abort – cause unknown

16:20 Start pre-cycle 18:11 – injecting again 19:22 - fan fault on the power supply for RQT12.R5B2.

Reset and go on. Problems loading collimator…

Friday 16th - afternoon

3

Page 4: Injection issues overnight 10:50 Access  QPS & EPC  Vacuum leak SPS – magnet to be replaced…

Zero injection frequency error AND Perfect Energy Matching. This shows as a very small transient on the Synchro Loop error (peaks at 7 deg max).

The initial slope of the Synchro Loop error gives the frequency error on first turns: we have ~ 4 deg in 100 turns = 8.9 ms -> 360 deg in 800 ms. That is a 1.2 Hz error at 400 MHz.

The slippage factor is -3.6E-4 at injection and a 10-4 DP/P gives 14 Hz error at 400 MHz. With 1.2 Hz the energy match is better than 10-5 DP/P

Injection beam 1 - perfect

4

Philippe Baudrenghien

Page 5: Injection issues overnight 10:50 Access  QPS & EPC  Vacuum leak SPS – magnet to be replaced…

10 degree phase error Synchro error: ~ 20 deg in 100 turns = 8.9 ms -> 360 deg in 160 ms -> 6 Hz error at 400 MHz or 0.5E-3 Dp/p

Try to balance energy mismatch between the two rings: add 5 HZ 400.788865 MHz

Injection beam 2

5

Page 6: Injection issues overnight 10:50 Access  QPS & EPC  Vacuum leak SPS – magnet to be replaced…

Phase and energy fairly well matched for both rings All bunches filled

length ranging from 1.27 ns to 1.52 ns

No more evidence of bunch lengthening during injections

Injection

6

Page 7: Injection issues overnight 10:50 Access  QPS & EPC  Vacuum leak SPS – magnet to be replaced…

Bunch length at injection

7

Page 8: Injection issues overnight 10:50 Access  QPS & EPC  Vacuum leak SPS – magnet to be replaced…

8

Nice injection….longitudinally much cleaner than last night, and in fact maybe 2-3 times lower losses on the TDI than over the previous week

(still not quite zero, but not far off)

Page 9: Injection issues overnight 10:50 Access  QPS & EPC  Vacuum leak SPS – magnet to be replaced…

00:44 Stable beams big beams… TFB on – helped lifetimes

04:38 Beam dump vacuum reading acquisition problem, vacuum interlock on

dilution kickers – to be followed up today 05:52 QPS OK lost on RB S56 - Looks like one heater

power supply (MB.C34R5) is slowly discharging. Access required – faulty switch (again)

Saturday 17th July

9