Page 1: Instruction Manual Sensorika Weighng Indicator 43000 Series

WEIGHING INDICATOR

ABS Enclosure IP 65 & IP67 Environmental Protection

43050 & 43050-W

OPERATION MANUAL

Page 2: Instruction Manual Sensorika Weighng Indicator 43000 Series

OPERATIONMANUAL SENSORIKA43050(W)

2

FCCNOTE: THISEQUIPMENTHASBEENTESTEDANDFOUNDTOCOMPLYWITHTHELIMITSFORACLASSADIGITALDEVICE,PURSUANTTOPART15OFTHEFCCRULES.THESELIMITSAREDESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST HARMFUL INTERFERENCEWHENTHEEQUIPMENTISOPERATEDINACOMMERCIALENVIRONMENT.THISEQUIPMENTGENERATES,USES, AND CAN RADIATE RADIO FREQUENCY ENERGY AND, IF NOT INSTALLED AND USED INACCORDANCE WITH THE INSTRUCTION MANUAL, MAY CAUSE HARMFUL INTERFERENCE TORADIOCOMMUNICATIONS.OPERATIONOFTHISEQUIPMENTINARESIDENTIALAREAISLIKELYTOCAUSEHARMFULINTERFERENCEINWHICHCASETHEUSERWILLBEREQUIREDTOCORRECTTHEINTERFERENCEATHISOWNEXPENSE.

INDUSTRYCANADANOTE:

THISCLASSADIGITALAPPARATUSCOMPLIESWITHTHECANADIANICES‐003.

CETAPPAREILNUMÉRIQUEDELACLASSEAESTCONFORMEÀLANORMENMB‐003DUCANADA.

Page 3: Instruction Manual Sensorika Weighng Indicator 43000 Series

OPERATIONMANUAL SENSORIKA43050(W)

3

TableofContents

1. INTRODUCTION 41.1 TECHNICALFEATURES 4

2. KNOWYOURINDICATOR 42.1 EXTERNALVIEWANDDIMENTIONS 42.2 OVERVIEWOFDISPLAYINDICATYORS 52.3 OVERVIEWOFINDICATOR’SCONTROLBUTTONS 5

3. INSTALLATION 63.1 UNPACKINGANDCHECKING 63.2 SELECTINGTHELOCATION 63.3 CONNECTINGINDICATORTOASCALEBASE 63.4 CONNECTINGPORTRS232 73.5 AC&DCPOWER 7

4. OPERATINGTHEINDICATOR 84.1 CALIBRATIONMENUTREE 84.2 SETUPMENUTREE 94.3 MENUDESCRIPTION 94.3.1 CALIBRATIONMENU 94.3.2 CALIBRATIONMENU­TORRATI NG THE I NDI C� 114.3.3 SETUPMENU(CUSTOMERSETTINGS) 124.3.3.1 CHECKWEIGHINGFUCTIONSETUP 124.3.3.2 PIECE­COUNTINGFUNCTIONSETUP 134.3.3.3 DIGITALTAREFUNCTIONSETUP 134.3.3.4 HOLDFUNCTIONSETUP 144.3.3.5 AUTOTAREFUNCTIONSETUP 144.3.3.6 FILTERFUNCTION 144.3.3.7 ANIMALWEIGHINGFUNCTION 144.3.3.8 BACKLIGHTFUNCTION 144.3.3.9 SOUND(BEEP)FUNCTION 144.3.3.10 AUTOPOWEROFFFUNCTION 154.3.3.11 COMUNICATIONWITHPRINTERORPC 154.3.3.12 SETUPPRINTINGFORMAT 154.3.3.13 A/DCONVERTORTEST 174.3.3.14 WEIGHINGUNITSENABLING/DISABLING 174.3.3.15 TIMEANDDATESETTING 174.3.4 ADDITIONALKEYFUNCTIONS 174.3.4.1 WEIGHTACCUMULATION 174.3.4.2 LOCKKEYBOARD 18

5. LIMITEDWARANTY 18

6. SHIPPINGINFORMATION 18

Page 4: Instruction Manual Sensorika Weighng Indicator 43000 Series

OPERATIONMANUAL SENSORIKA43050(W)

4

1. INTRODUCTION

ThankyouforchoosingSensorika43000Seriesweighingindicator.ThemodelsSensorika43050and43050‐Warerugged,reliableelectronicweighingindicatorsinanIP65(dustproof)andIP67washdownenclosuredesignedforeasyoperationinindustrialapplications.

The43000Seriescandriveupto12(twelve)350Ohmloadcells.TheIndicatorhasanenhanceddigitalfilterwhichallowsstabledisplayreadingevenifyousetthedisplayresolutionto1:100,000.

TheLCDdisplayhasbluebacklightand6digits,1”/2.5cminheight.Itprovideseasyreadingofdisplayfromadistanceorevenwithpoorlightingontheweighingstation.

Anadjustablemountingbracketallowstheindicatortobeinstalledonatable,wallorscalescolumn.

1.1 TECHNICALFEATURES

Capacity(lborkg) 1to999999DisplayResolution Max.100,000.Recommended:nomorethan30,000Weighingunits kg,g,lb,lb/oz

FunctionsPartcounting,Animalweighing,Accumulatingweight,Checkweigher,Doublerangescale,Digitaltare,etc.

Stabilizationtime ≤2secondsAutozerotrackingcapturerange 0~5.0divisionsZerorange 0~99%Spancalibration SelectablecalibrationweightWeighingsystem AnalogstraingaugeloadcellLoadcellexcitationvoltage 12VDCLoadcellinputsensitivity ≥2.0mV/VLoadcelldrive 1x1000Ohmorupto12x350OhmloadcellsDisplay 6DigitsLCDwithbluebacklight,digitsize1”/25mmPower Poweradapter100~240VAC50/60Hz/9VDC800mA

BatterylifeUpto60hrsofconstantusewith4loadcellandbacklightoff,

about30hrswithbacklightonOperatingtemperature 0°C~40°C(32°F~113°F)Keyboard 6mainboardbuttonsand5navigationkeysEnclosure ABSIP65orIP67

2. KNOWYOURINDICATOR

2.1 EXTERNALVIEWANDDIMENTIONS

Page 5: Instruction Manual Sensorika Weighng Indicator 43000 Series

OPERATIONMANUAL SENSORIKA43050(W)

5

Fig.1

2.2 OVERVIEWOFDISPLAYINDICATYORS

Fig.2

1 Stabilityindicator2 Netweightindicator3 “Minus”indicationofnegativeweight4 Indicatoroftare.ShowsthatTarevalueisstoredinRAM5 StableZeroindicator6 Externalpowerconnected7 Batteryloadindicator8 Weighingunitindicator9 Weighingunitindicator10 Partcountingindicator11 Weighingunitindicator12 Checkweighingindicator13 Dualplatformmodeindicator

2.3 OVERVIEWOFINDICATOR’SCONTROLBUTTONS

On/off button.

Unit selection button. It is used to select units (lb, oz, kg), piece-counting mode and as the Escape button in the Calibration or Setup menus.

Note: You can only select a unit that is enabled. To enable/disable units, go to parameter [Units] in the Customer Setup menu.

PLU button. Used to enter Setup or Calibration menus.

Page 6: Instruction Manual Sensorika Weighng Indicator 43000 Series

OPERATIONMANUAL SENSORIKA43050(W)

6

Gross/Net button. Press shortly to see Gross or Net weights. Press and hold to enter the Checkweighing mode.

Zero button. It sets the weight to zero. Press and hold the button to enter the Display Test mode.

Tare button. Press to accept recipient weight placed on the scale as tare. Press and hold to access the stored tare values.

MR and (LEFT) navigation key. Press to show accumulated total weight. In the menu mode, it is used to return to the previous step or escape from any parameter.

M+ and (RIGHT) navigation key. In the weight accumulation mode, press it to store and add the displayed weight to the value in memory.

1-2 and (UP) navigation key. Press to change from the scale plate to an external plate (only for double platform function scales). In the menu mode, it increases the value (number) on the display.

MC and (DOWN) navigation key. Press it to erase the accumulated weight from memory. In the menu mode, it decreases the value (number) on the display.

(ENTER) navigation key. Press to confirm the selection made in the programming mode. Press and hold to lock or unlock the keyboard.

3. INSTALLATION

3.1 UNPACKINGANDCHECKING

Openthepackageandremovetheinstrumentandtheaccessories.Checkthecompletenessofthedelivery.

Checktheinstrumentforanytransportdamages.Immediatelyinformyourdealerifyouhaveanycomplaintorseeanypartmissing.Yourindicatorpackageshouldcontain:

• IndicatorSensorika43050or43050‐W• Stainlesssteelbracketwithfixingknobs• 7–pinconnectorforloadcellcable(cableisnotprovided)• 8–pinconnectorforconnectionofPC,Remotedisplay,printerortarepedal(cablenotprovided)• Rechargeablebatterypack(internallyinstalled)• Poweradapter100~240VAC/9VDC800mA

3.2 SELECTINGTHELOCATION

Theweighingindicatorperformsthebestwhenworkinginanenvironmentfreefromaggressiveelements,vibrationsandextremetemperaturechanges.Thesefactorscanaffecttheaccuracyoftheweightreadings.Thescalebaseshouldbeplacedonastablehorizontalsurfaceawayfromvibrationsourcesandstrongmagneticfields.

3.3 CONNECTINGINDICATORTOASCALEBASE

WeighingindicatorSensorika43050(W)connectstothescalebasebya7‐pinBendixBayonetConnectorprovidedbymanufacturer.Loadcellcablefromscalebaseshouldbefixedtotheconnectorprovidedbyelectricalsolderaccordingtotheloadcellcableconnectionchart.(Fig.3).

Page 7: Instruction Manual Sensorika Weighng Indicator 43000 Series

OPERATIONMANUAL SENSORIKA43050(W)

7

Safetyprecautionsmustbetakenwhilesoldering,suchaswearingsafetyglassesandgloves.Alternatively,lookforaprofessionalorcontactdealertoconnecttheindicatortothescalebase.

NOTE:Sensorikascalebasesareequippedwitha7–pinfemaleconnectorandcanbeeasilyconnectedtotheindicator.

CAUTIONRISKOFELECTRIC

SHOCK

Unauthorizedandimproperuseofelectricsoldercancauseelectricshock

DANGERHOTSURFACE

Riskofsevereinjuriesorcauseafire

PINNUMBER CABLECONNECTIONORDER1 SIGNAL‐2 SIGNAL+3 EXCITATION‐4 SHIELD5 FREE6 EXCITATION+

7 EXCITATION+

Fig.3

Afterconnectorhasbeensoldered,proceedtoconnectthescalebasecabletotheindicator.

BesurethatIndicatorisswitchedoffwhenconnectingordisconnectingloadcellcable.

3.4 CONNECTINGPORTRS232

Soldercommunicationcabletothe8–pinconnectorprovidedaccordingtotheconnectionchart.

PINNUMBER CABLECONNECTIONORDER1 PRINTERCONNECTIONRXD22 PRINTERCONNECTIONTXD23 PRINTERCONNECTIONGND24 TAREPEDAL5 PCORSCOREBOARDCONNECTIONRXD16 PCORSCOREBOARDCONNECTIONTXD17 PCORSCOREBOARDCONNECTIONGND1

8 TAREPEDAL

Fig.4

3.5 AC&DCPOWER

TheSensorika43050(W)runsonACpoweradapterorrechargeablebattery.

ConnecttheACpowercordtoapoweroutlet.ThepowerplugisinEuropeanpowersocketstyle.Pleaseuseasocketadapterifyouwilluseitinotherregionswithdifferentelectricpowersocketstyles.

NOTE:SensorikaTechnologiesdoesnotprovidepowersocketadapters.

Theweighingindicatordisplayshowsthestatusofthebatteryload.Whenthebatteryloadlevelislow,thereisnoloadbarandthebattery‐chargingsymbolblinks.

Page 8: Instruction Manual Sensorika Weighng Indicator 43000 Series

OPERATIONMANUAL SENSORIKA43050(W)

8

4. OPERATINGTHEINDICATOR

WeighingindicatorSensorika43050(W)isnotsuitableforuseinhazardousareas.

Oncetheindicatorandscalebaseareconnectedandinstalled,followtheCalibrationandSetupmenutoobtainadesiredsettingofthescale.

RECOMMENDATION:Warmupthescalebeforecalibration.Switchthescaleonandletitstayforatleast1hourbeforeenteringthecalibrationmode.

4.1 CALIBRATIONMENUTREE

Fig.5

Page 9: Instruction Manual Sensorika Weighng Indicator 43000 Series

OPERATIONMANUAL SENSORIKA43050(W)

9

4.2 SETUPMENUTREE

Fig.6

4.3 MENUDESCRIPTION

Sensorika43050(W)hastwodifferentmenus‐CalibrationmenuandCustomerSetupmenu.Enterthesemenususing(PLU)button.

4.3.1 CALIBRATIONMENU

Pressandhold(PLU)buttonuntildisplayshows[PASS]

Page 10: Instruction Manual Sensorika Weighng Indicator 43000 Series

OPERATIONMANUAL SENSORIKA43050(W)

10

PASS Press(ENTER).Use(RIGHT),(LEFT),(UP)and(DOWN) navigationkeystoenterthepassword505388andpress(ENTER)key.

Use(Right)and(LEFT)navigationkeystonavigatethroughmenu,(ENTER)keytoenterthesub‐menusandconfirmsettings,then(UP)and(DOWN)navigationkeystoselectvalues.Use(U)buttonor[Quit]toescapefromCalibrationmenu.

UNits

Unitssubmenu.Thisfunctionallowsyoutosetup:1.Calibrationweighingunits:U2.Decimalplace:P3.Fullscalecapacity:FS4.Selectionofsingleordoublerange:RANGE5.Scaleweighingdivisions:dd1anddd26.Breakweightfordualweighingmode.

U 0

Calibrationweighingunits.Setupweighingunitstocalibratethescale:kg–0(bydefault)g–1lb–2

p 3

Setupthenumberofdecimalplacesonweighingdisplay:0–0(nodecimalpoint)1–0.02–0.003–0.0004–0.00005–0.00000

FS Fullscalecapacity.Inputthedesiredvalueusingthenavigationkeys.Beawarethatthetotalscalecapacitycannotexceedtheloadcellcapacity.

range 1 Setweighingrange:1‐single2‐dual

Dd1 02 Scaleweighingdivision:01,02,05,10,20,50.Ifyouselectsinglemode,setthisvalueandpress(ENTER)keytoreturntothebeginningof[UNITS]menu.Ifyouselectdualrangemode,proceedtothenextstep.

Dd2 05

Secondaryscaleweighingdivision.Indualmode,youneedtosetupasecondaryscaledivisionandabreakweightvalue.(Example:Ifthescale’stotalcapacityis30kgandyouwanttoweighwithaprecisionof2gupto10kg,andthenaprecisionof5gfrom10kgto30kg,setvaluedd1‐02,dd2‐05andthansetbreakvalue10.000.)

010.000 Setthebreakvaluefordualmodeandpress(ENTER)key.

SiCAL

Linearcalibrationmode.Thismodeallowslinercalibrationtominimizenon‐linearityparameter.Youcanperformupto10calibrationswithinthescale’scapacity.Generally2‐3calibrationsaresufficienttoreducenon‐linearitytotheacceptabletolerancelevelofLegalMetrology(evenonoldscales).Removeweightfromthescale,letitstabilizeandpress(ENTER)key.ItwillcalibratewithZeroweight.

Si- 01

Press(ENTER)again,inputthevalueofyourfirstcalibrationweight,applyweighttothescaleplatform,letitstabilizeandpress(ENTER).Theindicatorwillnowshow[Si‐02].Repeatprocedureforthenextcalibrationweight.Press(LEFT)navigationkeytoreturntotheCalibrationmenu.

Page 11: Instruction Manual Sensorika Weighng Indicator 43000 Series

OPERATIONMANUAL SENSORIKA43050(W)

11

CAL 1b

Simplecalibrationmode.Thismodeallowssimplecalibrationwhenlinearmodeisnotrequired.Press(ENTER)key,youwillsee6digitsnumberconstantlychanging.Thisvalueisinternalcountingoftheanalog/digitalconverter.ItshowsthatloadcellstatusisOK.Press(ENTER)tocontinue.

ZEro

Calibrationofzero.Removeweightfromthescale,letitstabilizeandpress(ENTER)key.Scalewillcalibratewithzeroweight.Inputthevalueofcalibrationweight,applyweighttothescaleplatform,letitstabilizeandpress(ENTER)key.Scaleiscalibratednow.

Ouit Press(LEFT)navigationkeyuntildisplayshows[Quit].Press(ENTER)keytosavethechangesandexitfromCalibrationmenu.

4.3.2 CALIBRATIONMENU‐ADDITIONALFUNCTIONS

FiLter Indicator’sinternalfiltervalue.Press(ENTER)toview.NOTE:thisisnotafilterusedforperformancespeedadjustment.Forperformancespeedadjustment,seeparameter[FiLter]locatedinSetupMenu.

ICS102 Weightcatchingtime.Factorydefaultis102.

rdS101 Deviationdata.Factorydefaultis101.

rdM101 Increaseddata.Factorydefaultis101.Press(RIGHT)navigationkeytwicetoproceedtonextparameter.

OIML

OIMLsubmenubelongstotheOIMLrequirementsofweighingindicators.[OIML0]–Manualsetting[OIML1]–OIMLautosettings.Choosevalue1toautomaticallysetupbelow3valuesaccordingtotheOIMLrequirements.

rS 02 Percentagerangeofscale’sfullcapacitythatcanbesettozerobypressing(ZERO)button.Valuecanrangefrom0to99%.

Or 16 Percentagerangeofscale’sfullcapacitythatthescaletakesasZerovaluewhenitisswitchedon.Valuecanrangefrom0to99%.

Ot 40 Percentagerangeofscale’sfullcapacityforautomaticZerotracking.Valuecanrangefrom0to99%.

Ouit Parameter[Quit]isusedtosavechangesandescapefromCalibrationmenu.

rESEt IMPORTANT!Thisfunctionresetsallsettingstofactorydefaults.

c1-c2

Dualplatformmodeindicator.Thisweighingindicatorcanbeusedwithtwoplatformssimultaneously(factoryinstallationrequired).Select0touseoneplatformandinvisibledisplayindicator(Fig.2pos.13);select1touseoneplatformandvisibledisplayindicator;select2touse2platformsandvisibledisplayindicator.

Page 12: Instruction Manual Sensorika Weighng Indicator 43000 Series

OPERATIONMANUAL SENSORIKA43050(W)

12

Adc

[AdcSr]‐Samplingspeed.Factorydefaultis20.[AdcGn]‐Amplifyingrate.Factorydefaultis2.Generallydon’tmakeanychangesinthisparameterunlessyouarefamiliarwiththesoftware.

rSt

Thisparameterisusedtoresetnegativeweighttozerowhenparameter[OIML]isactivated(setto1).(Example:ifparameterOIMLisactivatedandsomedeadweightsuchasscaleweighingpanwasremovedfromtheplatform,itwillshowanegativevaluewhichcannotberesettozerobypressingthe(ZERO)button.Inthiscase,setparameter[rSt]to1andpress(ENTER).Itwillnowsettheweighingvaluetozero).

zero

Thisparameterisusedtoadjusttheminimumdisplayweight.0–1d1–2d2–3d3–4d4–5d5–6d(wheredisscaleweighingdivision)

g1set Factorygravitycompensationvalue.Gravityvalueattheplacewherethescaleiscalibrated.

G2set Customergravitycompensationvalue.Gravityvalueattheplacewherethescaleisused.Ifitisusedattheplacewhereitwascalibrated,[g1Set]and[g2Set]shouldbethesame.

4.3.3 SETUPMENU(CUSTOMERSETTINGS)

Press(PLU)button,displaywillshow[PLUPro].

4.3.3.1 CHECKWEIGHINGFUCTIONSETUP

pLUPro ThisparameterisusedtosetupCheckweighingvaluesandstoretheminmemoryforupto20differenttargetweights.Press(ENTER)keytobegin.

PLU 01 Firsttargetsettings.Press(ENTER)tocontinue.

tAr

Hi

Lo

[tAr]willappearshortlyandthenindicatorrequiresaninputoftargetvalueusing(RIGHT),(LEFT),(UP)and(DOWN)navigationkeys.Press(ENTER)whenfinishinginput.Input[Hi]and[Lo]values.Thesearetheabsolutevaluesofthedifferencesbetweentargetweightandhigh/lowallowedweights(Example:targetweight=1.0kg,maximumallowedweight=1.1kg,minimumallowedweight=0.9kg.[Hi]=1.0–1.1=‐0.1=0.1kg,[Lo]=1.0–0.9=0.1kgSetup[Hi]=0.1and[Lo]=0.1.)Generallythesevaluesarethesamebutyoucaninputdifferentvaluesifrequired.

Btype1 Selectalarmmode:1–weightwithinrangealarm

Page 13: Instruction Manual Sensorika Weighng Indicator 43000 Series

OPERATIONMANUAL SENSORIKA43050(W)

13

2–weightoutofrangealarm.

bNode3

Selectauditablealarmtype:1–alarmdisabled2–beeponce3–continuousbeeps.Press(ENTER)key.Displayshows[PLU02].Proceedtothenextsetpoint.

4.3.3.2 PIECE‐COUNTINGFUNCTIONSETUP

Tosetuppiececounting,firstselectpiece‐countingmodeusing(U)button.Thecountingmodeindicatorappearsontherightsideofthedisplaywindow(fig.2,pos.10).Pressandhold(U)buttonformorethanasecond,aflushingnumber10willappear.Setupthesamplequantityyouwanttouse,from10to100(forsmallitemsaslargersamplequantitymoreprecisethecountingoperation)thanpress(ENTER).Thesamplevaluewillcontinueflushingfor5secondsthanstops.Yourscaleisreadyforpiececounting.

NOTE:Youloseyoursamplesettingswhenthescaleisturnedoff,unlessyousavethesampleweightsinmemory.

Youcansaveupto100samplevaluesinmemoryofweighingindicator.

Whenthescaleisinpiece‐countingmodeandsamplevaluealreadyconfigured,press(PLU)buttononce,displaywillshow[PLUPro].Use(RIGHT)navigationkeytoreach[CLUPro],press(ENTER)key.

CLU 01 Usenavigationkeystoselectthememorynumberwherethesamplevaluewillbestored,press(ENTER)tosave.Yourindicatorreturnsto[CLUPro]parameterafterthesampleweightisstored.

Torecallastoredsamplevalue,entertopiece‐countingmodeusing(U)button,thenpressandhold(B/N)buttonuntildisplayshows[CLU01].Inputamemorynumberwherestoreddesiredvalueandpress(ENTER).

4.3.3.3 DIGITALTAREFUNCTIONSETUP

Placethecontainerorotherobjectthatyouwanttotareandpressthe(TARE)button.Thescalewillthentaketheobjectastareanddisplaythenetweight.Press(B/N)buttontotogglebetweenGrossweightandNetweight.

Sensorika43050(W)canstoreupto20digitaltaresintheindicator’smemory.ThisfunctionisveryusefulwhenGrossandNetweightarebothrequiredbutitsimpossibletoseparatetheproductsfromtheirpackaging(bucket,pail,pallet,etc).Iftheweightofpackagingisknown,itcanbemanuallystoredintheindicator’smemoryandbeusedlater.Followthesestepstosavedigitaltaresinmemory.

Press(PLU)button.Use(RIGHT)navigationkeytoreach[tLUPro].

Torecalladigitaltarefromthememory,pressandhold(TARE)buttonuntil[tLU01]messageappears.Selectthenumberofmemorywhereyourdigitaltareisstoredandpress(ENTER).Thetarevaluewillbedisplayed.

tLUPro

Press(ENTER),selectoneofthe20memoriesdesignatedfordigitaltares,press(ENTER)again,enterthevalueofdigitaltareyouwishtostoreandpress(ENTER)tosaveit.Yourindicatorwillnowreturnto[tLUPro].Repeatthesameprocedureifyouwishtostoremoretares.

Page 14: Instruction Manual Sensorika Weighng Indicator 43000 Series

OPERATIONMANUAL SENSORIKA43050(W)

14

4.3.3.4 HOLDFUNCTIONSETUP

HoLd

Holdsubmenuhas5valuestoselect:0–holdfunctionisoff.1–indicatorcapturespeakvalues.Press(ZERO)buttontodropvaluetozero.2–indicatorcapturesvaluewhenweightisstable(stabilityindicatorison).Press

(ZERO)buttontodropvaluetozero.3–holdfunctionactivatestogetherwithstabilityindicator.Weighingindicatorholds

thevaluewhenweightisontheweighingplatform.Onceweightisremoved,displayreturnstozero.

4–holdfunctionactivatestogetherwithstabilityindicator.Weighingindicatorholdsthevalueevenwhenweightisremovedfromtheweighingplatform.Newholdvalueappearswhenanewobjectisplacedontheweighingplatform.

4.3.3.5 AUTOTAREFUNCTIONSETUP

Sensorika43050(W)canautomaticallytaketheweightofrecipientastare,weightheproductandresetscaletozerooncetherecipientwithproductisremovedfromtheplatform.

Press(PLU)button,scrollmenuwith(RIGHT)keyuntildisplayshows[AUt–t],press(ENTER)andselect1toenableAutoTarefunctionorselect0todisableit.

4.3.3.6 FILTERFUNCTION

FILter

Thisfunctionisusedtoadjustthesensibilityofthescale.Filtersubmenuhas6filterlevelstoadjust.0‐Scaleresponseisveryfastbutitcanbeunstableifscaledivisionissmall.Optimumfordynamicweighing.6–Scaleisverystablebuttheresponseistooslow.Optimumforunstableweighingobjectssuchasliquidsoranimals.Youshoulddecidetheappropriatefilterlevelbasedonyourimplementation.

4.3.3.7 ANIMALWEIGHINGFUNCTION

Sensorika43050(W)doesn’thaveaspecialsubmenuforanimalweighingbutitcanbeeasilysetupbycombiningtwofunctions‐HoldandFilter.SettheHoldfunctiontolevel4andFilterfunctiontolevel4,5or6dependingonanimalweight.Nowyoucanuseyourscaletoweighanimals.

4.3.3.8 BACKLIGHTFUNCTION

bL-SET

Selectoneofthe3availableoptions:On–backlightalwayson.Off–backlightalwaysoff.Auto‐backlightautomaticallyswitchedoffafter5secwhenstabilityindicatorappears.

4.3.3.9 SOUND(BEEP)FUNCTION

Insubmenu[bEEP],select1toactivateaudiblekeypadsoundorselect0todeactivateit.

Page 15: Instruction Manual Sensorika Weighng Indicator 43000 Series

OPERATIONMANUAL SENSORIKA43050(W)

15

4.3.3.10 AUTOPOWEROFFFUNCTION

Whendisplayshows[AUt‐0]press(ENTER)key.

oFF-3

Autooffmodecanbesetbetween0and4.0–autoofffunctionisdisable1–offafter2minwithoutuse2–offafter3minwithoutuse3‐offafter5minwithoutuse4‐offafter10minwithoutuse

4.3.3.11 COMUNICATIONWITHPRINTERORPC

ScrollSetupmenuuntildisplayshows[uArt],press(ENTER)key.

Br 001

Thefirstparameter[brXXX]isusedtosetcommunicationspeed(bauds)tofollowingvalues:001–1200002–2400004–4800009–9600019–19200038–38400057–56800058–115000

Followingparameters[dbit]and[PAri]arefixedandcannotbemodified.Theseparametersshowthelengthoftransmittingprotocolandparity.

Adr

ThisparameterisusedtosetthemodeoftransmittingofcommunicationprotocolforRemotedisplayorPC.0–transmittingisdisabled1–normaltransmittingconstantly2–inversetransmittingbydemandusing(ENTER)navigationkey3–inversetransmittingconstantlyParameters2and3areforscoreboardcommunication.

4.3.3.12 SETUPPRINTINGFORMAT

Fivedifferentprintingformatsinfourlanguagescanbeselectedinsubmenu[PrnFrM].

PrFM Usenavigationkeystoselectprintingformat.Press(ENTER)toconfirm.Seebelowexamplesofprintingformats.

Format1:

Format2:

Page 16: Instruction Manual Sensorika Weighng Indicator 43000 Series

OPERATIONMANUAL SENSORIKA43050(W)

16

Format3:

Format4:

Format5:

Page 17: Instruction Manual Sensorika Weighng Indicator 43000 Series

OPERATIONMANUAL SENSORIKA43050(W)

17

LFn 01 Setnumberofemptylinesbetweentheprinteddatablocks.Valuecanrangebetween00and99.

LAn 0

Selectoneofthefourlanguagesforprinting:0–English1–Spanish2–French3–German

4.3.3.13 A/DCONVERTORTEST

ICount DiagnosticofAnalog/Digitalconverter.Press(ENTER)toview.

Youwillseesixdigitsandsomeofthemareconstantlychanging.ItshowstheAnalog/Digitalconvertorisfunctioning.Thisinformationisusefulfortechnicaldiagnosticofweighingindicatorandloadcell.Inmostcases,ourTechnicalDepartmentisabletodiagnoseindicatororloadcellfailurewiththis6‐digitsnumberprovided.

4.3.3.14 WEIGHINGUNITSENABLING/DISABLING

Navigatetosubmenu[Unit].Thereare3weighingunitsthatcanbeenabledordisabled:lb,ozandcountingfunction.Setvalueto0todisable;1toenable(defaultunitiskgcannotbedisabled).

4.3.3.15 TIMEANDDATESETTING

Thisfunctionisanoptionalfeatureandcanberequestedfrommanufacture.

Navigatetosubmenu[rtc].

tImE Displaywillshow[tImE].Press(ENTER)keytosetuptime.Sixdigitstimeformatwillappear.Press(ENTER)forthenextstep.

dAtE Displayisshowing[dAtE].Press(ENTER)keytosetupdate.Sixdigitsdateformatwillappear.Setdateformatandpress(ENTER)toconfirm.

4.3.4 ADDITIONALKEYFUNCTIONS

4.3.4.1 WEIGHTACCUMULATION

Sensorika43050(W)canaccumulateweightvaluesondemand.Whenaweightisappliedtotheplatform,press(M+/RIGHT)navigationkey.Theweightoftheloadwillbestoredinmemoryoftheindicator.Removeweightfromtheplatform.Checkthatthedisplayreadingshowszero,applyanewweightandpress(M+/RIGHT)keyagain.Thenewweightwillbeaddedtothepreviouslyvaluestoredin

Page 18: Instruction Manual Sensorika Weighng Indicator 43000 Series

OPERATIONMANUAL SENSORIKA43050(W)

18

memory.Youcanaccumulateasmanyweightsasyouneed.Toseetheaccumulatedweight,press(MR/LEFT)key.

Toerasetheaccumulatedweightfromthememory,firstpress(MR/LEFT)keytodisplaytheaccumulatedweight,thenpress(UP)keyfollowedby(DOWN)key.Theaccumulatedweightisnowerased.

4.3.4.2 LOCKKEYBOARD

Tolockthekeyboard,pressandhold(ENTER)keyuntilmessage[Loch]appearsonthedisplay.Tounlockthekeyboard,pressandhold(ENTER)keyagainuntil[UnLoch]messageappears.

Mostkeysaredisabledwhenkeyboardislocked.

5. LIMITEDWARANTY

SensorikaTechnologiesproductsarewarrantedagainstdefectsinmaterialandworkmanshipfromthedateofpurchasethroughthedurationofthewarrantyperiod.Duringthewarrantyperiod,SensorikaTechnologieswillrepairor,atitsoption,replaceanycomponent(s)thatprovestobedefectiveatnocharge.

Thiswarrantydoesnotapplyiftheproducthasbeendamagedbyaccidentormisuse,exposedtoradioactiveorcorrosivematerials,penetrationofforeignmaterialstotheinsideofproduct,orasaresultofserviceormodificationmadebyanyoneotherthanSensorikaTechnologiesoritsauthorizeddistributorsand/orservicecenters.

6. SHIPPINGINFORMATION

Indicatorweight 2.20kg

Shippingpackingdimensions 26cmx26cmx15cm

Shippingweight 2.50kg