2
Instrumentation Cable APPLICATIONS • Predominantly used in utility substations • Can be installed indoors or outdoors, direct burial, free air, raceways, encased in concrete, open trays, troughs, or continuous rigid cable support • Other Uses Class 1 remote-control and signaling circuits Class 1, Division 2 hazardous locations • Conductor operating temperatures are not to exceed 90°C wet or dry • Rated 600 Volts CONSTRUCTION DETAILS • Conductors 18 or 16 AWG, 7 Strand, Annealed Bare Copper • Insulation Tough, Heat and Moisture Resistant Polyvinyl Chloride (PVC) • Color Code: (Pairs – Black, White, and Numbered) & (Triads – Black, White, Red, and Numbered) Conductor Jacket: Clear Nylon (polyamide) • Assembly Color-coded twisted pairs or triads; group of pairs or triads with numeric print identification on the groups Overall aluminum polyester foil with 100% coverage, tinned drain wire • Overall Jacket Heat, Moisture and Sunlight Resistant Black Polyvinyl Chloride (PVC) • Print PAIRS: SOUTHWIRE X PR OAS XXAWG SHIELDED (UL) TYPE TC 600V THHN/ TFFN SUN RES DIR BURIAL ROHS (MONTH/DAY/YEAR) SEQUENTIAL FOOTAGE MARKS TRIADS: SOUTHWIRE X TR OAS XXAWG SHIELDED (UL) TYPE TC 600V THHN/TFFN SUN RES DIR BURIAL ROHS (MONTH/DAY/YEAR) SEQUEN- SEQUENTIAL FOOTAGE MARKS SPECIFICATIONS Southwire’s Substation Instrumentation Cable meets or exceeds: • All Applicable ASTM Specifications • UL 83 • UL1277 • UL1581 • UL 1685 • IEEE 1202 • ICEA T-30-520 • RoHS Compliant OPTIONS Unshielded Pairs or Triads, with Overall Shield • XLP Insulated Conductors • Rip Cord Also Available in 300V Construction Upon Request SUBSTATION INSTRUMENTATION CABLE CONDUCTOR TYPE 18 – 16 AWG COPPER INSULATION TYPE PVC/NYLON JACKET TYPE PVC CONSTRUCTION AT A GLANCE 37 1 2 3 3 2 1

Instrumentation Cable - Southwire · Instrumentation Cable ApplICAtIons • Predominantly used in utility substations • Can be installed indoors or outdoors, direct burial, free

  • Upload
    letruc

  • View
    223

  • Download
    0

Embed Size (px)

Citation preview

Instrumentation Cable ApplICAtIons• Predominantly used in utility substations

• Can be installed indoors or outdoors, direct burial, free air, raceways, encased in concrete, open trays, troughs, or continuous rigid cable support

• Other Uses • Class 1 remote-control and signaling

circuits

• Class 1, Division 2 hazardous locations

• Conductor operating temperatures are not to exceed 90°C wet or dry

• Rated 600 Volts

ConstRUCtIon DEtAIls•Conductors

• 18 or 16 AWG, 7 Strand, Annealed Bare Copper

•Insulation

• Tough, Heat and Moisture Resistant Polyvinyl Chloride (PVC)

• Color Code:(Pairs – Black, White, and Numbered) & (Triads – Black, White, Red, and Numbered)

• Conductor Jacket:Clear Nylon (polyamide)

•Assembly

• Color-coded twisted pairs or triads; group of pairs or triads with numeric print identification on the groups

• Overall aluminum polyester foil with 100% coverage, tinned drain wire

•OverallJacket

• Heat, Moisture and Sunlight Resistant Black Polyvinyl Chloride (PVC)

•Print

• PAiRS: SOUTHWiRe X PR OAS XXAWG SHielDeD (Ul) TyPe TC 600V THHN/TFFN SUN ReS DiR BURiAl ROHS (MONTH/DAy/yeAR) SeqUeNTiAl FOOTAGe MARkS

• TRiADS: SOUTHWiRe X TR OAS XXAWG SHielDeD (Ul) TyPe TC 600V THHN/TFFN SUN ReS DiR BURiAl ROHS (MONTH/DAy/yeAR) SeqUeN-SeqUeNTiAl FOOTAGe MARkS

spECIFICAtIonsSouthwire’sSubstationInstrumentationCablemeetsorexceeds:• All Applicable ASTM Specifications

• Ul 83

• Ul1277

• Ul1581

• Ul 1685

• ieee 1202

• iCeA T-30-520

• RoHS Compliant

optIons• Unshielded Pairs or Triads, with Overall

Shield

• XlP insulated Conductors

• Rip Cord

• Also Available in 300V Construction Upon

Request

SUBSTATIONINSTRUMENTATIONCABLE

ConDUCtoR tYpE18 – 16 AWG COPPeR

InsUlAtIon tYpE PVC/NylON

JACKEt tYpE PVC

ConstRUCtIonAt A GlAnCE

37

1

2

3

32

1

SUBSTATIO

NIN

STRUM

ENTATIO

NCA

BLEIN

STRUM

ENTATIO

NCA

BLE

38

Dimensions and weights shown above are nominal and subject to industry tolerances.

SectionB

Size Numberof InsulationThickness

InsulationJacket

Thickness

OverallJacketThickness

NominalCoreDiameter

NominalOverall

Diameter

ApproximateWeight

AWGorkcmil

Pairs Triads inches mm inches mm inches mm inches mm inches mm lbs/1000ft

kg/km

18 1 - 0.015 0.38 0.004 0.1 0.045 1.14 0.167 4.2 0.26 6.6 38 57

18 - 1 0.015 0.38 0.004 0.1 0.045 1.14 0.181 4.6 0.28 7.1 47 70

16 1 - 0.015 0.38 0.004 0.1 0.045 1.14 0.191 4.9 0.29 7.4 49 73

16 - 1 0.015 0.38 0.004 0.1 0.045 1.14 0.206 5.2 0.30 7.6 61 91

18 2 - 0.015 0.38 0.004 0.1 0.045 1.14 0.377 9.6 0.48 12.2 84 125

16 2 - 0.015 0.38 0.004 0.1 0.045 1.14 0.429 10.9 0.53 13.5 106 158

18 4 - 0.015 0.38 0.004 0.1 0.045 1.14 0.471 12.0 0.57 14.5 131 195

16 4 - 0.015 0.38 0.004 0.1 0.045 1.14 0.536 13.6 0.64 16.3 173 257

18 8 - 0.015 0.38 0.004 0.1 0.060 1.50 0.630 16.0 0.76 19.3 245 365

16 8 - 0.015 0.38 0.004 0.1 0.060 1.50 0.717 18.2 0.85 21.6 327 487

18 12 - 0.015 0.38 0.004 0.1 0.060 1.50 0.770 19.6 0.90 22.9 339 504

16 12 - 0.015 0.38 0.004 0.1 0.060 1.50 0.876 22.2 1.01 25.7 459 683