IntelliConIntelliCon™™ Product Line Product LineManufactured byManufactured by
Intellidyne, Intellidyne, LLCLLC Distributed by:
IMC
Intellidyne, LLC
Intellidyne’s Product LineIntellidyne’s Product Line
Commercial Energy Economizers for: Hydronic & Steam Heating Systems Light-Commercial Hydronic & Steam Heating Systems
Residential Energy Economizers for: Hydronic Heating Systems
Intellidyne, LLC
Heating System EconomizersHeating System Economizers
Beckett HeatManagerBeckett HeatManager
IntelliConIntelliCon™™-HW-HWIntelliConIntelliCon™™-LCH-LCH
IntelliCon - CHWIntelliCon - CHW
IntelliConIntelliCon™™-LCS & HP-LCS & HP
IntelliConIntelliCon™™-CHS & HP-CHS & HP
Intellidyne, LLC
Heating System BasicsHeating System Basics A heating system must be able to provide acceptable
comfort at the lowest anticipated outdoor temperature.
In the U.S. and abroad, most boilers have a heat capacity between 1.5 to 2 times larger than that needed to maintain the space temperature on these extreme days.
Due to over-sizing of the boiler, the burner cycles on and off continuously to prevent overheating of the system water during any call for heat.
The Burner cycling rate is directly proportional to the Heating load and System losses.
The relative over-sizing is greatest in the spring and fall and minimal in the dead of winter.
Intellidyne, LLC
Hydronic Heating System Hydronic Heating System Economizers: Economizers: How They WorkHow They Work
In much the same way as Outdoor Air Reset Control changes boiler water temperature to match anticipated heating demands, and thus improve system efficiency, using our patented technology has the same Energy-Saving effect without the pitfalls. Microprocessor monitors outflow water temperature
and rate of change continuously from strap-on temperature sensor.
Intellidyne, LLC
Hydronic Heating System Hydronic Heating System Economizers: Economizers: How They WorkHow They Work Microprocessor detects changes in system
load through analysis of temperature changes. Based on analysis an optimum hold-off
temperature is computed. Microprocessor inhibits Burner firing until hold-
off temperature is reached. Microprocessor is continuously monitoring
load changes and re-computing the hold-off temperature.
Intellidyne, LLC
Hydronic Heating System Hydronic Heating System Economizers: Economizers: How They WorkHow They Work Microprocessor allows Burner to Fire once
the hold-off temperature is reached. The Burner controls then takeover and control the duration of Burner firing.
Intellidyne, LLC
Heating Product Validation Heating Product Validation TestingTesting
ETL Testing Labs– 12% Fuel Savings -”Winter” Loading– 27% Fuel Savings - “Spring-Fall” Loading
Brookhaven National Labs– 14% Reduction of Fuel Consumption– 64% Reduction of Burner Cycles
Atlantic Testing Labs– 15% Savings - Field Test in New Energy
Efficient Home
Intellidyne, LLC
Heating Product Validation Heating Product Validation Testing (continued)Testing (continued)
Brooklyn Union– Space Temperature Testing
Improved Space Temperature Consistency While Saving Fuel
– Concept Tested with Customers Placed First When Tested in a Group of 9
Competing Products– Instrumented Field Test ( Jan 98- April 98)
14.7% Fuel Savings on High Efficiency Gas Boiler
Intellidyne, LLC
Typical Savings from IntelliConTypical Savings from IntelliCon™™ Heating Heating System Economizer InstallationsSystem Economizer Installations
Church Location Savings
St Anthony – Bronx NY 30.35%St. Anthony of Padua – Yulan NY 16.41%St. Peter – Monticello NY 19.02%Sacred Heart – Patterson NJ 10.54%Immaculate Conception – Woodbourne NY 11.36%St Joseph – Croton Falls NY 21.78%St. Mary – Newburgh NY 17.46%St Patrick – Newburgh NY 17.65%Kennedy High School – Somers NY 15.31%St Catherine Laboure – Lake Katrine NY 9.93%St Elizabeth Ann Seton – Shrub Oak NY 24.37%The Magdilene – Pocantino Hills NY 15.96%
Intellidyne, LLC
Heating System Economizers: Heating System Economizers: BENIFITSBENIFITS
Reduces Fuel Consumption 10 to 20%. Validated by Laboratory and Field Tests.
Short Payback Period - Typically 6 to 18 Months. Extends Boiler Life by Reducing Burner Cycling
30% or more. No Programming or Maintenance Required. Reduces Burner Emissions Dramatically by
Reducing the Number of Burner Starts. Reduced System Maintenance.
Intellidyne, LLC
Heating System Economizers: Heating System Economizers: FEATURESFEATURES
Low Installed Cost. State of the Art Microprocessor Controller. Indicator Lights/Display Shows Operating Modes
and Conditions. Simple Installation. Easily Installed Plug-In Sensor(s). No Programming Involved. No Follow-up Visits
Required. UL Listed.
Intellidyne, LLC
Intellidyne Economizers:Intellidyne Economizers: Benefits to CustomerBenefits to Customer
Significant Energy Savings – 10% to 20% Fuel Savings for Heating
Low Pay-back Period– 4 months to 1 year- Commercial Heating– 1½ years to 2½ years - Residential Heating
Quick Installation - No Maintenance Extends Equipment Life - Due to reduced Run-Time Reduces Air Contaminants - For A Cleaner Environment
Intellidyne, LLC
Contact Contact IMCIMC904 579 1091 Tel904 579 1091 Tel904 265 2078 Fax904 265 2078 [email protected]@imcjax.com
Ask how much you can save Ask about the 10% guarantee Ask about the 15 year warranty Ask about your free trial installation Ask about our satisfied clients Ask about our independent lab test reports Ask about our program for Boiler service
companies Start saving energy immediately