6
INSTALLATION MANUAL LHF868-RS RADIO RECEIVER ACCESS CONTROL ONLY LHF RADIO ACCESS CONTROL 24/ 7/ 365 www.baticonnect.com LHF868-RS RADIO RECEIVER remotely programmable via BATICONNECT ® CLOUD

IPDE LHF Radio Receiver Manual - ipdoorentry.co.uk

  • Upload
    others

  • View
    11

  • Download
    0

Embed Size (px)

Citation preview

INSTALLATION MANUALLHF868-RS RADIO RECEIVER

ACCESS CONTROL ONLY

LHF

RADI

OAC

CESS

CO

NTR

OL

24/7/365www.baticonnect.com

LHF868-RS RADIO RECEIVERremotely programmable via

BATICONNECT® CLOUD

PO

+ -

12V

+ –

+ –

485REL 2

NO C NC

REL 1

NO C NC

BS

C S E

REL 4

NO C NC

1 2 3 4 5 6

REL 3

NO C NC

3-core 1.5mm2�ex cable (3183Y)

DOORCONTACT

POWER IN12VDC/2AMP PSU

(NOT FOR LOCKING)

IGSMDATA4MODEM

CONNECTS LHF RADIORECEIVER TO

BATICONNECT.COMCLOUD

EXIT ENTRY

ANTAERIAL CONNECTION

DOOR IDNUMBER SWITCH

POWERLED

MAGNETIC INDUCTIONLOOP CONTACTS

DOOR STATUSCONTACTS

DATA BUSD2

LHF868-RS-4 RADIO RECEIVER

164mm

93m

m

FORINFORMATION

ONLY

CODE LED

RADIO LED

FORINFORMATION

ONLY

FORINFORMATION

ONLY

FORINFORMATION

ONLY

D2

+ –

IGMSDATA4

Class E (CAT6) U/UTP

1 2

3 4

Button 1 = Relay 1Button 2 = Relay 2Button 3 = Relay 3Button 4 = Relay 4

2

LHF RADIO RECEIVER

AR122 PSU12VDC/2A

for LHF Radio Receiver Only

NETWORK ADDRESS SETTINGS

* IGSMDATA32 only for settings 05–16

1 3 52 4 6 = 06*

1 3 52 4 6 = 05*

1 3 52 4 6 = 04

1 3 52 4 6 = 03

1 3 52 4 6 = 02

1 3 52 4 6 = 01

DOOR ID SWITCH

TEL868-0 RADIO TRANSMITTERS

3

LHF868-RS-4 RADIO RECEIVERLOCKING CABLING

NO

C

NC

+

-12V DC FAIL SECUREELECTRIC RELEASE

VARISTOROR DIODE

EXIT BUTTON

LOCK OUTPUTRELAY

FORINFORMATION

ONLY

TO +

+ -

DEDICATED12VDC/2AMP

PSU

FORINFORMATION

ONLY

NO

C

NC

VARISTOROR DIODE

LOCK OUTPUTRELAY

+

-

12V DC MAGNET ORFAIL SAFE RELEASE

If your fail safe locking requires an EmergencyBreakglass Exit Device (EMEX with a normallyclosed contact) to comply with Building Safetyregulations, please �t as shown.

EMEX

TO +

+ -

DEDICATED12VDC/2AMP

PSU

EXIT BUTTON

FORINFORMATION

ONLY

NO

C

NC

LOCK OUTPUTRELAY

TO AUTOMATIONCONTROLEXIT BUTTON

FAIL SECURE LOCKING LHF RELAY 1 (SAME FOR RELAYS 2, 3 & 4)

FAIL SAFE LOCKING LHF RELAY 1 (SAME FOR RELAYS 2, 3 & 4)

AUTOMATION CONTROL / VOLT-FREELHF RELAY 1 (SAME FOR RELAYS 2, 3 & 4)

4

Wall mounting plate dimensionsCase dimensions

60mm

130mm

164mm

93mm 50mm

Bracket, aerial and RG58 coaxial cable (5 metres) included

8mm screw fixings

M4

5

LHF RADIO RECEIVER

Core sizesq.mm

No ofcores

Radial thickness of insulation mm

Nominal overall diameter mm

Weightkg/km

1 4 0.6 7.9 99

Fail safe locking relies on the locking receiving the correct voltage and current. Fail secure electro-mechanical locking always requires a 3rd core control cable. Only industry reference 4 x 1 YY/LSZH cabling (or Fire Protected equivalent, if applicable) is to be used. Alarm, data or communications cabling; for example; CAT5E, CW1308 is unacceptable.

T: 01322-441165 Product ref: 3184B-Grey Part number: 45574 www.batt.co.uk

Maximum distance from locking to power supply location:50 metres for 1 amp lock30 metres for 2 amp lock

CABLE REFERENCE:4 x 1 YY/LSZH

PER LOCK

Conductors: Flexible copper, class 5.

Core identification: 4 core: brown, grey, black, green/yellow

Insulation: LSZH

Sheath/Jacket: LSZH

Colour: Grey

Voltage: 300/500V

Operating temperature: -5°C / + 70°C

Minimum bending radius: 6 x overall diameter

Standards: BS EN 50525-3-11, EN 61034-2, EN 60332-1-2.

LOCKING CIRCUIT CABLE 4 x 1 YY/LSZH (3184B LSZH)

PROTECTION VARISTOR OR DIODE FOR LOCKING

CABLES CPR COMPLIANT TO CCA, S1B, D2, A2 OR BETTER

Q13026

+

+

The use of a varistor or diode protects electrical equipmentfrom transient voltage spikes.

Diode

Varistor

DC releaseFail Secure or

Fail Safe

K = Cathode +

ElectroMagnet

A = Anode –

releaseElectroMagnet

AC or DC

+

Fit the diode ref. IN4001close to the DC releaseor electro-magnet.

Respect polarity of thediode. Incorrect �tting ofa diode will cause ashort circuit.

K

A

K

A

Fit the varistor close to theAC or DC release or theDC magnet.

Varistor is polarityinsensitive.

++

or

DD

D DV Vor

Refer to Construction Products Regulations (CPR)-BS6701 and ISO/IEC 11801-6: 2017 Part 6: Distributed Building Services (or BS EN 50173-6:2018 Part 6: Distributed Building Services).

1. Only use CPR compliant cabling.2. Never use BT cable ref. CW1308 for access control systems.3. Make sure duct or external grade cable equivalents are used

whenever applicable.4. Any and all system/equipment guarantees relating to correct

functionality and reliability only apply if 1st fix cabling, cables used, and mains power requirements are provided strictly in accordance with the installation instructions supplied.

LHF868-RS-1 RADIO RECEIVER LHF868-RS-4 RADIO RECEIVER

REFERENCES LHF868-RS-1 LHF868-RS-4

MECHANICAL CHARACTERISTICS

Dimensions (HxWxD) 164 x 93 x 50 mm

Weight 350g

Material ABS

IP protection IK08 / IP65

ELECTRICAL CHARACTERISTICS

Voltage 12VDC

Consumption 150 mA

Power supply 12VDC / 2A

Relay 1no 5 Amp rated NO/NC programmable 4no 5 Amp rated NO/NC programmable

Operating temperature -20°C to 65°C

FEATURES

Bus Max length 400 metres using Class E (CAT6) U/UTP in series

Capacity 2000 radio transmitters

Frequency 868MHz

Range Maximum 50 metres with no obstructions

Magnetic induction loop contacts Yes

Door status contacts Yes

Calendar function 8no week types with baticonnect.com

Programming www.baticonnect.com available 24/7/365

SPECIFICATIONS

© Copyright 2020 IP Door Entry Limited. All rights reserved.

24/7/365www.baticonnect.com08000 156496

[email protected] ipdoorentry

IP Door Entry LimitedUnit DC4 Prologis ParkEastman WayHemel HempsteadHP2 7DU