2
© 2013 MIMAKI ENGINEERING CO., LTD. D202613-10-12132013 JFX500 / UJV500 Series If negative pressure abnormality occurs If an error related to pressure abnormality occurs, immediately adjust the pressure with the following procedures and return it to the normal value. 1. Select [PRESSURE ADJUST] of the maintenance menu. (1) Press the key. (2) Press to select [MAINTENANCE] and press the key. (3) Press to select [PRESSURE ADJUST]. 2. Press to select POSITIVE or NEGATIVE. Adjust the throttle valve in order of “negative pressure” “positive pressure” “negative pressure”. 3. Press the key. 4. Remove the cover under the left maintenance cover. (UJV500) 5. Rotate the adjustment screw of the throttle valve to release it so that air can flow. Loosen the fixing screws on the throttle valve, and turn the adjustment screw until it reaches the midpoint. <LOCAL> NEGATIVE PRESSURE <LOCAL> POSITIVE PRESSURE ERROR 61e NEGATIVE P. OVER PRESSURE ADJUST : NEGAT I VE Open Throttle Valve COMPLETED [ ENT ] Turn the adjustment screw to this position. Adjustment screw Positive pressure Negative Pressure Adjustment screw Adjustment screw for positive pressure UJV500: JFX500: Adjusting negative pressure / positive pressure Negative pressure : Turn the adjustment screw clockwise to increase negative pressure. Positive pressure : Turn the adjustment screw clockwise to increase positive pressure. •When adjustment is complete, carefully tighten the fixing screws. Fixing screw Fixing screw Adjustment screw for negative pressure Fixing screw Fixing screw IT

JFX500 / UJV500 Series If negative ... - Mimaki Globaleng.mimaki.co.jp/archives/034/JFX500_UJV500_If... · © 2013 MIMAKI ENGINEERING CO., LTD. D202613-10-12132013 JFX500 / UJV500

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: JFX500 / UJV500 Series If negative ... - Mimaki Globaleng.mimaki.co.jp/archives/034/JFX500_UJV500_If... · © 2013 MIMAKI ENGINEERING CO., LTD. D202613-10-12132013 JFX500 / UJV500

JFX500 / UJV500 Series

If negative pressure abnormality occurs

If an error related to pressure abnormality occurs, immediately adjust the pressure with thefollowing procedures and return it to the normal value.

1. Select [PRESSURE ADJUST] of the maintenance menu.

(1) Press the key.

(2) Press to select [MAINTENANCE] and press the key.

(3) Press to select [PRESSURE ADJUST].

2. Press to select POSITIVE or NEGATIVE.Adjust the throttle valve in order of “negative pressure” “positive pressure” “negative pressure”.

3. Press the key.

4. Remove the cover under the left maintenance cover.(UJV500)

5. Rotate the adjustment screw of the throttle valve torelease it so that air can flow.Loosen the fixing screws on the throttle valve, and turn the adjustmentscrew until it reaches the midpoint.

< L O C A L >

N E G A T I V E P R E S S U R E

< L O C A L >

P O S I T I V E P R E S S U R E

E R R O R 6 1 e

N E G A T I V E P . O V E R

PRESSURE AD J UST: NEGAT I VE

Op e n T h r o t t l e V a l v eCOMP L ETED [ ENT ]

Turn the adjustment screw to this position.

200

250

160

170

180

190

210

220

230

240

260

270

50

70

100

150

10

20

30

40

60

80

90

110

120

130

140

03

Adjustment screw

Positive pressure

Negative Pressure

Adjustment screw

Adjustment screw for positive pressure

UJV500: JFX500:

Adjusting negative pressure / positive pressureNegative pressure : Turn the adjustment screw clockwise to increase negative pressure.Positive pressure : Turn the adjustment screw clockwise to increase positive pressure.

•When adjustment is complete, carefully tighten the fixing screws.

Fixing screw

Fixing screwAdjustment screw for negative pressure

Fixing screw

Fixing screw

© 2013 MIMAKI ENGINEERING CO., LTD. D202613-10-12132013 IT

Page 2: JFX500 / UJV500 Series If negative ... - Mimaki Globaleng.mimaki.co.jp/archives/034/JFX500_UJV500_If... · © 2013 MIMAKI ENGINEERING CO., LTD. D202613-10-12132013 JFX500 / UJV500

6. Press the key.Sensor adjustment starts.

7. Rotate the adjustment screw of the throttle valve to adjust thepressure so that it becomes the proper value•Proper value of negative pressure: -5.4kPa•Proper value of positive pressure: 15.00kPa•As the negative pressure changes between ±0.1 and 0.2kPa, adjust so that the intermediate value may become the target pressure.•Adjust the throttle valve in order of “negative pressure” “positive pressure” “negative pressure”.

8. Press the key.The error is released and the negative pressure control starts.

* * AD J UST I NG * *P L EASE WA I T

PRESSURE= - 4 . 0 0 k P a

• Status of lamp and buzzer for each pressure value

PressureInk bottle lamp Buzzer

Positive pressure Negative pressure

High

~ 8.49 ~ -4.75

Sounds

8.50 ~ 9.49 -4.76 ~ -4.85

9.50 ~ 10.49 -4.86 ~ -4.95

10.50 ~ 11.49 -4.96 ~ -5.05

11.50 ~ 12.49 -5.06 ~ -5.15

12.50 ~ 13.49 -5.16 ~ -5.25

13.50 ~ 14.49 -5.26 ~ -5.35 Stops

Proper value 14.50 ~ 15.49 -5.36 ~ -5.45 Stops

Low

15.50 ~ 16.49 -5.46 ~ -5.55 Stops

16.50 ~ 17.49 -5.56 ~ -5.65

Sounds

17.50 ~ 18.49 -5.66 ~ -5.75

18.50 ~ 19.49 -5.76 ~ -5.85

19.50 ~ 20.49 -5.86 ~ -5.95

20.50 ~ 21.49 -5.96 ~ -6.05

21.50 ~ 22.49 -6.06 ~ -6.15

22.50 ~ 23.49 -6.16 ~ -5.86.2

23.50 ~ -6.26 ~

• Pressure is informed with the buzzer and the ink bottle lamp as well as thescreen display.

• For the negative pressure, the buzzer stops within the range of ±0.1kPa. For thepositive pressure, the buzzer stops within the range of ±1.0kPa.

Ink bottle lampJFX500: UJV500:

Ink bottle lamp

P L EASE WA I T