88
TS Twin impeller single stage MS Single impeller single stage MD Single impeller double stage TD Twin impeller double stage DESIGNS designs “GO R ” “GVR ” Design Design Standard Design The standard FPZ design is a direct drive configuration, with a dynamically balanced impeller fitted directly on the motor shaft. Fitted motors are 2-pole, 1 or 3 phase, rated for continuous service. Standard motors utilize class F insulation, are suitable for use with a variable speed drive (3 phase only), and are tropicalized for corrosion resistance. S le or two stage options are pictured above. GOR / GVR Design “GOR / GVR” designs utilize a standard nema (or metric) electric motor that is directly coupled to the blower shaft. This direct coupled design allows the use of specialty motors that may be required to meet a variety of electrical requirements. For some models the vacuum / pressure capabilities can be increased with this GOR / GVR design (pictured right).  FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268-0180 [email protected] www.fpz.com ing

k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 [email protected] applications APPLICATIONS Thousands of FPZ blowers

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

TSTwin impeller single stage

MSSingle impeller single stage

MDSingle impeller double stage

TDTwin impeller double stage

DESIGNSdesigns

“GO R” “GVR ” Design Design

Standard Design

The standard FPZ design is a direct drive configuration, with a dynamically balanced impeller fitted directly on the motor shaft. Fitted motors are 2-pole, 1 or 3 phase, rated for continuous service. Standard motors utilize class F insulation, are suitable for use with a variable speed drive (3 phase only), and are tropicalized for corrosion resistance. S le or two stage options are pictured above.

GOR / GVR Design “GOR / GVR” designs utilize a standard nema (or metric) electric motor that is directly coupled to the blower shaft. This direct coupled design allows the use of specialty motors that may be required to meet a variety of electrical requirements. For some models the vacuum / pressure capabilities can be increased with this GOR / GVR design (pictured right).  

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

ing

Page 2: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

applicationsAPPLICATIONS

Thousands of FPZ blowers are working in a variety of

applications: from commercial to industrial installations,

in food processing to pharmaceuticals, from textiles to

aerospace, in medical applications to environmental.

Wherever efficiency and reliability are needed, FPZ

responds with the appropriate product “solution”

- Compact execution- Simple concept- Reduced maintenance costs- Modular design

Advantages of side channel blowers

- Pulsation and oil free air

Blowers have an impeller blade m ounted inside a housing. As air passes the inlet port, impellerblades draw air in and accelerate the air outwardand forward. As each imeller blade strikes it,the air m oves faster a n d faster. At the base of the hous ing an air stripper divthe hou s ing redu cing the s peed and the nincreasing .

How Blowe

erts the air out of

the pressure

rs Work

Page 3: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

SS140 Table of Contents

Page(s)General Pressure and Vacuum Performance Curves 4 5

K Series "MOR" Blowers - Direct Drive Max CFM

Max Pressure (In H2O)

Max Vacuum (In Hg.) Pressure Vacuum

SCL K03-K06 MS Single Stage Blowers 216 132 9.6 6-7 40-41SCL K07-K12 MS Single Stage Blowers 726 211 11.1 8-9 42-43SCL K05-K06 TS Single Stage Blowers 400 85 6.3 10-11 44-45SCL K07-K12 TS Single Stage Blowers 1410 110 8.1 12-13 46-47SCL K07R-12 MD Two Stage Blowers 336 300 14.7 14-15 48-49SCL K04-K06 TD Two Stage Blowers 222 180 11.8 16-17 50-51SCL K07-K12 TD Two Stage Blowers 716 225 13.2 18-19 52-53

06 / R20-MD / DH Blowers Performance DataSCL 06 Single Stage Blowers 39 52 3.5 20-21 54-55SCL 10DL-15DH Two Stage Blowers 35 120.5 8.1 22-23 56-57SCL R20-MD; 30DH-40DH Two Stage Blowers 98 201 11.1 24-25 58-59K Series Direct Coupled - "GOR/GVR" configurationSCL K03-K06 MS-GOR/GVR Single Stage Blowers 216 140 9.6 26-27 60-61SCL K07-K12 MS-GOR/GVR Single Stage Blowers 726 200 10.3 28-29 62-63SCL K05-K06 TS-GOR/GVR Single Stage Blowers 400 130 7.8 30-31 64-65SCL K07-K12 TS-GOR/GVR Single Stage Blowers 1410 150 10.3 32-33 66-67SCL K07R- K12 MD GOR/GVR Two Stage Blowers 336 280 14.7 34-35 68-69SCL K07-K12 TD GOR/GVR Two Stage Blowers 716 225 13.2 36-37 70-71SCL K09-K11 TT GOR/GVR Three Stage Blowers 597 340 17 38-39 72-73Values in above table based on 60 hz performance

AccessoriesInstallation Guide General guide on how to install accessories. 74VRL6-9 Safety valve selection guide 75VRL6-9 Safety Valves 76VRL6HP / VRL8HP High pressure safety valves 77CSL / CT Filters for vacuum applications. 78FS Filter / Silencers for pressure applications 79VG-020-013 Dirty Filter Indicator 80VS 6 / VS 8 Flow Converting Devices for diverting air stream 81VK / PK Flange Connectors for safety valves and flexible hoses 82CA / CK Filter Manifolds and 90 Degree Manifold for K series blowers 83VG / PG / CV / SS / IH Gauges, Check Valves, Silencers, and Sound Enclosures 84MF / TF / MP Flexible Sleeves, Flanges, Sleeves 85

TechnicalSingle phase motor information 86Three phase motor information 87Airflow Through an Orifice 88FPZ Pneumatic Range 89

DisclaimerThe information contained in this catalog is based on information that we believe to be correct. It is the users responsibility to determine the suitability of the product for the application they are used in and the user assumes all risk and liability whatsoever in connection therewith.

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

2

Page 4: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Pressure Performance Curves

3

10

7 1/2

5 1/2

4

K07-MS

5 1/2

7 1/2

K08-MS

15

10

K10-MS

25

15

20

10

7 1/27 1/2

10

15

K07-TS

10

15

7 1/2

K08-TS

15

20

25

K10-TS

20

15

10

7 1/2

K09-MS

15

20

25

K09-TS

10

15

20

25

30

K11-TS

5 1/2

4

3

K05-TS

K06-TS

7 1/2

1/2

1/3

16001200 14001000900800700600500400350300250 200 150 100 75 50 25 0

0

20

40

60

80

100

120

140

160

180

200

220

Capacity (cfm)

Stat

ic d

iffer

entia

l pre

ssur

e ( I

n W

G)

25

K05-MS

4

3

2

5 1/2

K06-MS

3

4

3/4

K03-MS

2

1 1/2

10

6 1/5

K04-MS

1

5 1/2

06

Legend

K10-TS

25Model

Installed power

7 1/2

5 1/2

4

3

K08-MD

15

7 1/2

K10-MD

15

20

10

7 1/2

7 1/2

10

15

K07-TD

10

15

7 1/2

K08-TD

15

20

25

K10-TD

15

10

7 1/2

K09-MD

15

20

25

K09-TD

10

15

25

20

25

K11-TD

2

5 1/2

3

K06-TD

5 1/2

10

3/4

3

4

1/

3

30

700650600550500450400 350300250200175150 125 100 75 50 25 800

0

20

40

60

80

100

120

140

160

180

200

220

240

260

280

300

320

0

Stat

ic d

iffer

entia

l pre

ssur

e ( I

n W

G)

10

K07-MD

7 1/2

20

4

Legend

K10-TD

25Model

Installed power

2

1

5 1/2

5 1/2

Curves refer to air at 68°F temperature and 29.92 In Hg atmospheric pressure (abs) measured at inlet port. Tolerance on given values ± 10% - data can change without prior notice.

Capacity (cfm)

15

20

K11-MS

K12-MS

25

K11-MD

K12-MD

25

20

15

K12-TS30

25

3

2

K04-TD

1/2

3

K12-TD

4

1 1/2

R20-MD

30DH

40DH

15DH

10DL

K05-TD

sschultz
Line
Page 5: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Vacuum Performance Curves

4

15

20

25

15

20

25

25

30

1

2 3

2

K05-MS

6 1/5

5 1/2

4

3

K06-MS

10

7 1/2

5 1/2

4

K07-MS

5 1/2

7 1/2

K08-MS

15

10

K09-MS

15

20

10

7 1/2

20

15

10

7 1/2

K10-MS

10

15

20

5 1/2

4

3

K05-TS

K06-TS

7 1/2

10

7 1/2

10

15

K07-TS

10

15

7 1/2

K08-TS

600 1100800450 1000900700500400350300250 200 150 100 75 50 25 0 1200 1400 1600

K09-TS

K10-TS

K11-TS

1/2

1/3

06

0

20

40

60

80

100

120

140

160

Capacity (cfm)

Stat

ic d

iffer

entia

l pre

ssur

e ( I

n W

G)

3

Capacity (cfm)

Stat

ic di

ffer

entia

l pre

ssur

e ( I

n W

G)

K07-MD

3

4

5 1/2

7 1/2

K08-MD

10

7 1/2

5 1/2

K09-MD

10

7 1/2

5 1/2

K10-MD

15

10

7 1/2

20

15

10

K05-TD

3

4

5 1/2

10

K06-TD

7 1/2

5 1/2

7 1/2

10

15

K07-TD

15

10

7 1/2

K08-TD K09-TD

25

20

K10-TD

25

20

15

25

20

550 800650450 750700600500400 350300250200150 100 75 50 25 0

10DL

1/3

15DH

3/4

1

2

30DH

3

40DH

0

20

40

60

80

100

120

140

160

180

200

220

Curves refer to air at 68° F temperature, measured at inlet port and 29.92 In Hg atmospheric backpressure (abs).Tolerance on given values ± 10% - data can change without prior notice.

K11-MD

K12-MD

20

15

K11-MS

K12-MS

25

15

20

Legend

Installed power

odelM25

TSK10-

25

Legend

Model

K10-TD

Installed power

K12-TS30

K11-TD

K1 -TD2

30

3/4

K03-MS

1 1/2

1/2

5 1/2

1 1/2

2

K04-TD

5

R20-MD

1 1/2

K04-MS

sschultz
Line
sschultz
Line
sschultz
Line
Page 6: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

TECHNICAL CHARACTERISTICS - Aluminium alloy construction - Smooth operation - High efficiency impeller - Maintenance free - Mountable in any position - Recognized TEFC - cURus motor

OPTIONS - Special voltages (IEC 38) - Surface treatments

ACCESSORIES - Inlet and/or inline filters - Additional inlet/outlet silencers - Safety valves - Flow converting device - Optional connectors

Model Maximum

flow Scfm

Installed power

Hp

Maximum differential pressure

p ( In WG )

Noise level Lp dB (A)

(1)

Overall dimensions

H Weight

60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm Inches Lbs

3/4 3/4 64 60 62.0 60.0 10.43 24.30 K03-MS 52 43

1 1 95 77 62.3 60.3 11.97 26.50 1 ½ 1 ½ 58 80 64.8 62.8 11.65 36.40

2 2 85 100 65.0 63.0 13.78 43.00 K04-MS 98 81 3 - 120 - 65.2 - 13.78 49.60 2 2 52 70 70.5 68.5 13.20 51.80 3 3 90 110 70.8 68.8 13.20 58.40 K05-MS 156 129

4 4 128 120 71.1 69.1 14.40 67.20 3 3 50 65 73.0 71.0 13.54 68.70 4 4 75 95 73.3 71.3 14.17 71.65

5 ½ 5 ½ 110 140 73.6 71.6 14.17 77.60 K06-MS 216 179

6 1/5 (2) - 132 - 73.9 - 14.45 77.60

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744. (2) No cURus motor

Model a b c d e f G I m n o p1 q r s t u z

K03-MS 9.49 10.55 5.79 1.69 9.06 8.07 1”1/4 NPT 3.39 0.39 3.27 5.59 8.07 0.71 2.95 0.16 M6 5.51 0.47 K04-MS 11.22 12.40 6.77 1.93 10.04 8.86 1” 1/2

K05-MS K06-MS 14.80

e

a

fIG

d

c

b

s

p1

o

Ømn r q

z

H

3x120°øu

t

Accessory

SCL K03 / K04 / K05 / K06

SN 1874- 1/2

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request. - Ambient temperature from +5° to +104°F. - Specifications subject to change without notice.

Dimensions in inches. Dimension for reference only.

MS SERIES

12.87 7 .87 2.13 12.60 10.24 2” NPT .59 .16 8 .87 .75 0 M 7 0 0 4. 27 15.47 8.07 2.13 12.80 11.42 2” NPT . 14.37

NPT 4.02 0.47 3.74 6.73 8.74 0.71 2.76 0.16 M6 6.89 0.71

4.92 0.59 5.51 10.71 13.15 0.71 3.35 0.16 M8 9.45 0.75 10 .43 12.60 0 .71 .4 53 3.86

6 REGENERATIVE BLOWERS - PRESSURE

9

Page 7: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

CAPA

CITY

A

BSO

RBED

PO

WER

TE

MPE

RATU

RE IN

CREA

SE

SCL K03 / K04 / K05 / K06

SN 1874-9 2/2

Curves refer to air at 68°F temperature and 29.92 In Hg

Data subject to change without notice.

p

psig

0

1

2

3

4

5

0 50 100 150 200 250

4

K05-MS

3

2

0

20

40

60

80

100

120

140

In W

G

Scfm

60 Hz6 1/5

5 1/2

4

K06-MS

3

3

2

1 1/2

K04-MS K03-MS

3/4

1

p

psig

0

1

2

3

4

5

0

20

40

60

80

100

140

0 1 2 3 4 5 6 7

K06-MS K05-MS

60 Hz

Hp

In W

G

K04-MS

K03-MS

0

1

2

3

4

5

p

psig

In W

G

0

20

40

60

80

100

120

140

160

0 50 100 150 200 Scfm

50 Hz

4

3

3

5 1/2

4

1 1/2

2

3/4

K03-MS K04-MS

2

K05-MS K06-MS

1

0

1

2

3

4

5

p

psig

In W

G

0

20

40

60

80

100

120

160

0 1 2 3 4 5 6

50 Hz

Hp

K05-MS

K06-MS

K04-MS

K03-MS

p

psig

0

1

2

3

4

5

K05-MS K04-MS

60 Hz

K06-MS

0

20

40

60

80

100

140

0 20 40 60 80 100 120 140 °F

In W

G

K03-MS

0

1

2

3

4

5

p

psig

0 20 40 60 80 100 120 140 160 180 200 °F

In W

G

0

20

40

60

80

100

120

16050 Hz

K05-MSK06-MS

K04-MS

K03-MS

MS SERIES

atmospheric pressure (abs) measured at inlet port.

REGENERATIVE BLOWERS - PRESSURE 7

Values for flow, power consumption and temperature rise: +/ 10% tolerance. -

Page 8: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Model Maximum

flow Scfm

Installed power

Hp

Maximum differential pressure

Dp ( In WG )

Noise level Lp d B (A)

(1)

Overall dimensions

H Weight

60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm Inches Lbs

K07-MS 294 243

4 4 50 63 78.7 76.7 15.45 103.00 5 ½ 5 ½ 75 86 79.0 77.0 15.45 107.10 7 ½ 7 ½ 130 138 79.3 77.3 18.37 145.70 10 10 181 161 79.6 77.6 18.37 154.50

K08-MS 381 316

5 ½ 5 ½ 40 52 79.7 77.7 15.45 115.70 7 ½ 7 ½ 68 90 80.0 78.0 18.37 154.30 10 10 115 125 80.3 78.3 18.37 163.10 15 15 181 181 80.6 78.6 19.15 184.00

K09-MS 471 390

7 ½ 7 ½ 50 63 80.2 78.2 18.84 166.50 10 10 80 95 80.5 78.5 18.84 175.10 15 15 140 155 81.0 79.0 19.63 196.20 20 20 181 181 81.3 79.3 23.74 269.00

K10 -MS 556 460

7 ½ 7 ½ 36 51 80.1 78.1 18.84 170.90 10 10 64 80 80.5 78.5 18.84 179.50 15 15 120 135 81.0 79.0 19.63 200.60 20 20 167 191 81.4 79.4 23.74 273.40 25 25 211 201 81.6 79.6 24.61 298.70

K11 -MS 650 539

10 10 40 53 82.0 80.0 19.04 194.90 15 15 82 97 82.4 80.4 19.83 216.00 20 20 125 141 82.7 80.7 23.94 288.80 25 25 162 201 85.6 83.6 24.81 313.10

K12 -MS 726 602 15 15 52 90 82.9 80.9 19.95 223.70

20 20 85 130 83.2 81.2 24.06 296.50 25 25 14 0 160 86.1 84.1 24.92 320.80

SCL K07 / K08 / K09 / K10 / K11 / K12 SERIES MS

SN 1805 15 1/2 -

TECHNICAL CHARACTERISTICS - Aluminium alloy construction - Smooth operation - High efficiency impeller - Maintenance free - Mountable in any position - Recognized TEFC - cURus motor

OPTIONS - Special voltages (IEC 38) - Surface treatments

ACCESSORIES - Inlet and/or inline filters - Additional inlet/outlet silencers - Safety valves - Flow converting device - Optional connectors

Dimensions in inches. Dimension for reference only.

Model a b c d e f G I m n o p1 q r s t u z

K07-MS 16.69 18.84 10.59 3.23 18.43 17.24 3” NPT 6.10 0.51 11.81 13.78 20.16 0.98 5.39 0.20 M8 11.61 0.63 K08-MS 17.99 19.61 10.59 3.23 18.82 17.64 3” NPT 6.10 0.51 11.81 13.78 20.16 0.98 5.39 0.20 M8 12.2 0.63 K09-MS 19.37 22.09 12.40 3.78 20.00 18.82 4” NPT 7.17 0.51 11.81 13.78 23.07 0.98 7.83 0.20 M8 14.17 0.63 K1 MS 0- 20.31 22.56 12.40 3.78 20.00 18.82 4” NPT 7.17 0.51 11.81 13.78 23.07 0.98 7.83 0.20 M8 14.17 0.63 K11 MS - 21.34 23.74 13.07 3.58 21.26 20.00 4” NPT 7.87 0.51 11.81 13.78 23.46 0.98 8.03 0.20 M8 15.35 0.63 K1 -MS 2 21.57 23.82 13.07 3.58 21.26 20.00 4” NPT 7.87 0.51 11.81 13.78 23.58 0.98 8.03 0.20 M8 15.35 0.51

- For proper use, the blower should be equipped with inlet filter and safe . ty valve; other accessories available on request- Ambient temperature from +5° to +104°F. - Specifications subject to change without notice.

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.

Accessory

r q

p1 H

o

n

øm

3x120° øu

z

t

G

d

c b

e

f

I

a

s

8 REGENERATIVE BLOWERS - PRESSURE

Page 9: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Curves refer to air at 68°F temperature and 29.92 I . n Hg atmospheric pressure (abs) measured at inlet portValues for flow, power consumption and temperature rise: +/ 10% tolerance. -Data subject to change without notice.

ABS

ORB

ED P

OW

ER

TEM

PERA

TURE

IN

CREA

SE

SCL K07 / K08 / K09 / K10 / K11 / K12 MS SER IES

SN

180

2/2

5-15

0

1

2

3

4

5

6

7

8

p

psig

0

20

40

60

80

100

120

140

160

180

200

240

In W

G

0 100 200 300 400 500 700 Scfm 600

10

7 1/2

4

7 1/2

15

10

25

15

20

10

7 1/2

20

15

10

15

10

7 1/2

20

5 1/2

5 1/2

K07-MS

K10 -MS K08-MS

K11 -MS K09-MS

K12 -MS

15

20

25

50 Hz

25

Hp 0

20 40 60 80

100 120 140 160 180

240

0 5 10 15 25

In W

G

20

K07-MS

K10 -MS

K11 -MS K09-MS

K08-MS

K12 -MS

50 Hz

0

1

2

3

4

5

6

7

8

p

psi

g

0

1

2

3

4

5

6

7

8

p

psig

0

20

40

60

80

100

120

140

160

180

240

0 20 40 60 80 100 120 140 160 180 200 °F

K07-MS

K11 -MS

K10 -MS

50 Hz

In W

G

K09-MS

K08-MS

K12 -MS

CAPA

CITY

0 100 200 300 400 500 600 800 Scfm 700

10

7 1/2

4

7 1/2

15

10

25

15

20

10

7 1/2

20

15

10

25

15

10

7 1/2

20

5 1/2

5 1/2

K07-MS K08-MS K10 -MS

K11 -MS K09-MS K12 -MS

20

15

60 Hz

0

20

40

60

80

100

120

140

160

180

240

In W

G

200

0

1

2

3

4

5

6

7

8

p

psig

25

0

1

2

3

4

5

6

7

8

p

psig

Hp

K07-MS

K10 -MS

0

20 40 60 80

100 120 140 160 180

240

0 5 10 15 20 25

In W

G 60 Hz

K11 -MS

K09-MS

K12 -MS

K08-MS

0

1

2

3

4

5

6

7

8

p

psig

K11 -MS

0 20

40

60

80

100

120

140

160

180

240

0 20 40 60 80 100 120 140 160 180 200

K08-MS

K10 -MS

60 Hz

°F

In W

G

K09-MS

K12 -MS

K07-MS

REGENERATIVE BLOWERS - PRESSURE 9

Page 10: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Model a b c d e f G I m n o p1 q r s t u z

K05-TS 12.87 16.61 10.16 3.03 15.91 14.72 3” NPT 5.91 0.51 11.81 13.58 24.96 0.98 12.91 0.16 M8 7.87 0.75 K06-TS 14.80 17.72 10.31 2.95 15.91 14.72 3” NPT 6.10 0.51 1 1.81 13.58 26.06 0.98 13.19 0.16 M8 9.45 0.75

Model Maximum

flow Scfm

Installed power

Hp

Maximum differential pressure

p ( In WG )

Noise level Lp dB (A)

(1)

Overall dimensions

H Weight

60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm Inches Lbs

K05-TS 290 241 3 3 30 45 72.0 70.0 17.45 85.98 4 4 46 70 73.5 71.5 18.64 89.29

5 ½ 5 ½ 72 100 75.5 73.5 18.64 93.70

K06-TS 400 331 5 ½ 5 ½ 36 55 77.2 75.2 18.98 104.72 7 ½ 7 ½ 55 65 77.5 75.5 22.60 141.09 10 10 85 93 77.8 75.8 22.60 149.91

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.

SCL K05 / K06 SERIES TS

SN 1921 1/2 -6

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories ava ilable on request.- Ambient temperature from +5° to +104°F. - Specifications subject to change without notice.

Accessory s G

e f I

d

c b

a

r o n

øm q

3x120°øu t

z H

p1

TECHNICAL CHARACTERISTICS - Aluminium alloy construction - Smooth operation - High efficiency impeller - Maintenance free - Mountable in any position - Recognized TEFC - cURus motor

OPTIONS - Special voltages (IEC 38) - Surface treatments

ACCESSORIES - Inlet and/or inline filters - Additional inlet/outlet silencers - Safety valves - Flow converting device - Optional connectors

Dimensions in inches. Dimension for reference only.

10 REGENERATIVE BLOWERS - PRESSURE

Page 11: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

CAPA

CITY

A

BSO

RBED

PO

WER

TE

MPE

RATU

RE

INCR

EASE

SCL K05 / K06

TS SERIESSN 1921-6 2/2

60 Hz

0

20

40

60

80

100

0 100 200 300 400 500 Scfm

K05-TS

5 1/2

4

3 K06-TS

5 1/2

7 1/2

10

20

40

60

80

100

120

0 50 100 150 200 250 300 350 400 0

Scfm

50 Hz

In W

G

K05-TS

K06-TS

5 1/2

4

3

5 1/2

7 1/2

10

p

psig

0

1

2

3

4

0 1 2 3 4 5 6 7 8 Hp 9 10 0

20

40

60

80

120

In W

G

K05-TS

K06-TS

50 Hz

p

psig

0

1

2

3

0.5

1.5

2.5

3.5 60 Hz

0

20

40

60

80

100

0 1 2 3 4 5 6 7 8 Hp

In W

G

9 10

K05-TS

K06-TS

p

psig

0

1

2

3

4

K06-TS

50 Hz

0 20 40 80 140 °F 60 100 120

K05-TS

0

20

40

60

80

120

In W

G

p

psig

0

1

2

3

0 5 .

1.5

2.5

3.5

K05-TS

K06-TS

0 20 40 60 80 °F 0

20

40

60

80

100

In W

G 60 Hz

p

psig

0

1

2

3

0.5

1.5

2.5

3.5

0

1

2

3

4

REGENERATIVE BLOWERS - PRESSURE 11

Curves refer to air at 68°F temperature and 29.92 In Hg atmospheric pressure (abs) measured at inlet port. Values for flow, power consumption and temperature rise: +/-10% tolerance. Data subject to change without notice.

p p

sig

Page 12: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request. - Ambient temperature from +5° to +104°F. - Specifications subject to change without notice.

Model Maximum

flow Scfm

Installed power

Hp

Maximum differential pressure

∆p ( In WG )

Noise level Lp dB (A)

(1)

Overall dimensions

H Weight

60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm Inches Lbs

7 ½ 7 ½ 36 48 83.9 81.9 23.76 197.31 10 10 60 71 84.2 82.2 23.76 206.13 K07-TS 588 487

121 84.8 82.8 24.55 223.77 7 ½ 7 ½ 18 30 80.8 78.8 23.76 205.47

K08-TS 715 592 15 15 75 87 83.3 81.3 24.55 231.92 20 20 80 90 85.0 83.0 350.53

K09-TS 941 780 25 25 10 120 85.0 30.79 383.60 20 20 65 75 88.1 86.1 354.94 K10-TS 1093 906 25 25 80 95 88.4 86.4 30.79 388.01 25 25 50 69 89.4 87.4 31.38 K11-TS 1254 1039 30 (2) 30 (2) 70 90 90.0 88.0 31.38

K12-TS 1410 1168 30 (2) 30 (2) 45 80 90.6 88.6 31.50 436.75

Model a b c d e f G I j k m n o p1 q r s t u z

K07-TS 16.69 20.91 12.56 3.86 18.43 17.24 7.17 - - 0.51 9.84 21.65 31.57 0.98 11.77 0.20 M8 11.61 0.63K08-TS 18.03 21.57 12.56 3.86 18.82 17.64 7.17 - - 0.51 9.84 21.65 31.57 0.98 11.77 0.20 M8 12.20 0.63K09-TS 19.37 24.02 14.37 4.41 20.00 18.82 5.12 8.27 M16 8.27 0.51 9.84 21.65 33.46 - 12.40 0.20 M8 14.17 0.63K10-TS 20.31 24.53 14.37 4.41 20.00 18.82 5.12 8.27 M16 8.27 0.51 9.84 21.65 33.46 - 12.40 0.20 M8 14.17 0.63K11-TS 21.26 25.59 14.96 4.17 21.26 20.08 5.12 21.65 34.25 - 12.60 0.20 M8 15.35 0.63

K12-TS 21.57 25.66 14.96 4.17 21.26 20.08 5 1.2 M16 8.27 0.51 9.84 21.65 34.37 - 12.60 0.20 M8 15.35 0.63

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744. (2) K11-K12-TS Hp 30 vertical assembly only.

For model K09/K10/ K11/K12-TS only

j Int.k

øG

SCL K07 / K08 / K09 / K10 / K11 / K12SERIES

Dimensions in inches. Dimension for reference only.

TECHNICAL CHARACTERISTICS - Aluminium alloy construction - Smooth operation - High efficiency impeller - Maintenance free - Mountable in any position - Recognized TEFC - cURus motor - G1/8” female thread on both suction

and discharge silencer port flanges

OPTIONS - Special voltages (IEC 38) - Surface treatments

ACCESSORIES - Inlet and/or inline filters - Additional inlet/outlet silencers - Safety valves - Flow converting device - Optional connectors

s G

e f I

d

c b

a

G 1/8”

For model K11-K12-TS Hp 30 60Hz only

Accessory

t

r o

n n øm

q

z H

p1

3x120°øu

TS

0.51 9.84

1 1105 15

10 10 37 50 80.9 78.9 23 76. 214.29

1

M16 8.27

12 REGENERATIVE BLOWERS - PRESSURE

87.0

8.988.98

SN 1822-12

4”NPT 4”NPT

29.92

29.92

429.02434.53

Page 13: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

CAPA

CITY

A

BSO

RBED

PO

WER

TE

MPE

RATU

RE IN

CREA

SE

SCL K07 / K08 / K09 / K10 / K11 / K12SERIES

Curves refer to air at 68°F temperature and 29.92 In Hg atmospheric pressure (abs) measured at inlet port. Values for flow, power consumption and temperature rise: +/-10% tolerance. Data subject to change without notice.

K07-TS

K08-TS

K09-TS

K10-TS K11-TS

0

20

40

60

80

120

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 Hp

60 Hz

In W

G

p

psi

g

0

1

2

3

4

K12-TS

p

psi

g

0

1

2

3

4

5

K07-TS

K08-TS

K09-TSK10-TS

K11-TS

0

20

40

60

80

100

140

0 2 4 6 8 10 12 14 16 18 20 22 24 26 Hp

50 Hz

In W

G

K12-TS

p

psi

g

0

1

2

3

4

5

100

140

K12-TS

0

20

40

60

80

0 20 40 60 80 100 120 °F

In W

G 50 Hz

K07-TS

K09-TS

K08-TS

K10-TS

K11-TS

p

psi

g

0

1

2

3

4

0

20

40

60

80

120

0 20 40 60 80 100 °F

60 Hz

K09-TS

K07-TS

K08-TS

K10-TS

In W

G

K11-TS

K12-TS

p

psi

g

0

1

2

3

4

5

In W

G

0

20

40

60

80

100

120

140

0 200 400 600 800 1000 1200 Scfm

50 Hz

K07-TS K08-TS

K09-TS K10-TS

K11-TS

20

25

15

10

7 1/210

15

7 1/2

25

20 30

25

30

K12-TS

p

psi

g

0

1

2

3

4

Scfm

In W

G

20

25

0

20

40

60

80

100

120

200 400 600 800 1000 1200 1400

15

10

7 1/2 10

15

K08-TS

K07-TS 7 1/2

25

20

K09-TS

K10-TS

30

25

K11-TS

1600

60 Hz

K12-TS

30

TS SN 1822-12

REGENERATIVE BLOWERS - PRESSURE 13

Page 14: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Model a b c d e f G I m n o p1 q r s t u z

K07R-MD 16.69 18.94 10.59 3.23 18.43 6.10 0.51 0.20 K08R-MD 17.99 19.61 3.23 18.82 17.64 2” NPT 6.10 0.51 K09-MD 19.37 22.09 12.40 3.78 20.00 18.82 4” NPT 7.17 0.51 1.81 3.78 25.35 0.98 10.12 0.20 M8 14.17 0.63 K10-MD 20.31 22.56 12.40 3.78 20.00 18.82 7.17 K11-MD 1.35 23.74 13.07 3.58 21.18 20.00 7.87 0.51 10.31 0.63 K12-MD 21.57 23.85 13.07 3.58 21.18 20.00 4” NPT 7.87 0.51 11.81 25.87 0.98 10.31

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.

Model Maximum

flow Scfm

Installed power

Hp

Maximum differential pressure

p ( In WG )

Noise level Lp dB (A)

(1)

Overall dimensions

H Weight

60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm Inches Lbs

3 3 68 87 73.5 71.5 16.14 101.40 4 4 110 128 74.0 72.0 16.14 103.60

5 ½ 5 ½ 150 170 74.5 72.5 16.14 111.50 K07R-MD 129 107

7 ½ 7 ½ 260 260 75.0 73.0 17.52 134.50 5 ½ 5 ½ 85 110 76.2 74.2 16.14 116.90 7 ½ 7 ½ 162 185 76.6 74.6 17.52 140.00 10 10 240 260 77.0 75.0 17.52 151.00

K08R-MD 168 139

15 - 260 - 77.3 - 17.52 173.00 5 ½ 5 ½ 54 78 76.9 74.9 16.54 144.40 7 ½ 7 ½ 120 143 78.0 76.0 17.95 167.60 10 10 190 210 79.5 77.5 17.95 178.60

K09-MD 221 183

15 15 290 290 80.5 78.5 19.29 200.60 7 ½ 7 ½ 85 110 79.9 77.9 17.91 170.90 10 10 140 165 80.3 78.3 17.91 181.90 15 15 245 270 81.4 79.4 19.29 203.90

K10-MD 275 228

20 20 300 300 81.7 79.7 22.97 270.00 10 10 100 125 81.1 79.1 18.11 11.60 15 15 190 220 81.4 79.4 19.49 232.60 20 20 280 300 81.7 79.7 23.23 287.20

K11-MD 306 254

25 - 300 - 82.0 - 23.23 353.30

15 15 100 180 82.3 80.3 19.61 240.30 20 20 180 260 82.6 80.6 23.42 295.00 K12-MD 336 278

25 - 250 - 82.9 - 23.42 361.00

SCL K07R / K08R / K09 / K10 / K11 / K12

SN 1848-9 1/2

- For proper use, the blower should be equipped with inlet filter - Ambient temperature from +5° to +104°F. - Specifications subject to change without notice.

Dimensions in inches. Dimension for reference only.

TECHNICAL CHARACTERISTICS - Aluminium alloy construction - Smooth operation - High efficiency impeller - Maintenance free - Mountable in any position - Recognized TEFC - cURus motor

OPTIONS - Special voltages (IEC 38) - Surface treatments

ACCESSORIES - Inlet and/or inline filters - Additional inlet/outlet silencers - Safety valves - Flow converting device - Optional connectors

a

b

c

d

e f I

G s

n o

r q øm

H p1

3x120° øu

t

z

MD SERIES

2

2

10.59 17.24 2” NPT

0.51 11.81 13.78 2 5.35 0 .98 10.12 0.98

31.78 16.46 0.71 1.70 0.63 0.63

0.63

11.61 12.20

14.171 1

1 3.78 16.46

0 .71 1.70 0.20 M8

M8 M8

15.35 15.35 0.62

0.20 M8 0.20

M8

0.20

11.81

13.78 25.75

11.81

and safety valve; other accessories available on request.

14 REGENERATIVE BLOWERS - PRESSURE

4” NPT4” NPT

13.7811.81

Page 15: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

CAPA

CITY

A

BSO

RBED

PO

WER

TE

MPE

RATU

RE IN

CRES

ASE

Curves refer to air at 68°F temperature and 29.92 In Hg atmospheric pressure (abs) measured at inlet port. Values for flow, power consumption and temperature rise: +/-10% tolerance. Data subject to change without notice.

SN 1848- 2/2

p

psig

0

1

2

3

4

5

6

7

8

9

10

11

12

In W

G

20

7 1/2

10

15

K10-MD

0 100 200 300 400 Scfm

60 Hz

K08R-MD

10

7 1/2

15

K07R-MD

3

4

7 1/2

15

10

7 1/2

K09-MD K11-MD

10

15

20 25

0 20

40

60

80

100

120

140

160

180

200

220

240

260

280

340

5 1/2

5 1/2

5 1/2 K12-MD

15

20

25

p

psig

0

1

2

3

4

5

6

7

8

9

10

11

12

In W

G

K10-MD

0 20

40

60

80

100

120

140

160

180

200

220

240

260

280

340

0 100 200 300

50 Hz

Scfm

K08R-MD

K07R-MD K09-MD K11-MD

20

7 1/2

10

15 10

7 1/2

3

4

7 1/2

15

10

7 1/2 10

15

20

5 1/2

5 1/2

5 1/2

20

15

K12-MD

0 1

2

3

4

5

6

7

8

9

10

11

12

p

psig

0 20 40 60 80

100 120 140 160 180 200 220 240 260

340

0

In W

G

2 4 6 8 10 14 16 18 12 20 22 24 Hp

K07R-MD

K08R-MD

K09-MD

K10-MD

K11-MD

K12-MD

60 Hz

p

psig

0 1

2

3

4

5

6

7

8

9

10

11

12

0 20 40 60 80

100 120 140 160 180 200 220 240 260

340

0 20 40 60 80 100 120 140 160 180 200

K11-MD

In W

G 60 Hz

°F

K07R-MD

K08R-MD

K09-MD K10-MD

K12-MD

p

psig

0

1

2

3

4

5

6

7

8

9

10

11

12

In W

G

0 20 40 60 80

100 120 140 160180200220240260

340

0 20 40 60 80 100 120 140 160 180 200

50 Hz

°F

K08R-MD

K07R-MD

K09-MD

K12-MD

K11-MD

K10-MD

0

1

2

3

4

5

6

7

8

9

10

11

12

p

psig

020406080

100120140160180200220240260

340

0 2 4 6 8 10 12 16 18 Hp

In W

G

14

50 Hz

K07R-MD

K08R-MD

K09-MD

K10-MD

K11-MD

K12-MD

MD SERIES

REGENERATIVE BLOWERS - PRESSURE 15 SCL K07R / K08R / K09 / K10 / K11 / K12

9

Page 16: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Model Maximum

flow Scfm

Installed power

Hp

Maximum differential pressure

p ( In WG )

Noise level Lp dB (A)

(1)

Overall dimensions

H Weight

60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm Inches Lbs

K04-TD 99 82 2 2 70 95 71.0 69.0 17.26 62.83 3 3 130 160 72.0 70.0 17.26 69.44

K05-TD 153 127 3 3 70 95 73.0 71.0 17.45 84.88 4 4 105 135 74.5 72.5 18.64 88.18

5 ½ 5 ½ 150 190 76.0 74.0 18.64 92.59

K06-TD 222 184 5 ½ 5 ½ 80 120 75.0 73.0 18.98 103.62 7 ½ 7 ½ 125 140 76.0 74.0 22.60 139.99 10 10 180 200 77.0 75.0 22.60 148.81

(1) Noise measured at 1 m distance with i nlet and outlet ports piped, in accordance to ISO 3744.

Model a b c d d1 e f G I1 I2 m n o p1 p2 q r r1 s t u w x y z

K04-TD 11.22 12.40 6.77 1.93 4.76 10.04 8.86 1” ½ NPT 4.84 2.01 0.47 3.74 6.73 12.44 10.00 0.71 2.76 0.59 0.16 M6 6.89 7.40 8.43 6.81 0.71

K05-TD 12.87 14.37 7.87 2.13 5.51 12.60 10.24 2” NPT 5.71 2.36 0.59 4.53 10.43 16.85 13.39 0.71 3.86 1.57 0.16 M8 7.87 11.26 11.54 8.11 0.75

K06-TD 14.80 16.54 9.13 2.32 6.69 12.80 11.42 2” NPT 5.94 2.87 0.59 5.51 10.43 19.92 13.94 0.71 5.35 0.75 0.16 M8 9.45 11.26 12.13 8.27 0.75

SCL K04 / K05 / K06TD SERIES

1/2 -6 SN 1931

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request. - Ambient temperature from +5° to +104°F. - Specifications subject to change without notice.

a

d

b

c

s

e f

I2 G

t

3x120° øu

y I1 q

d1

w

45° G

p1 H

z

q

o

p2 x

n r øm

r1

TECHNICAL CHARACTERISTICS - Aluminium alloy construction - Smooth operation - High efficiency impeller - Maintenance free - Mountable in any position - Recognized TEFC - cURus motor

OPTIONS - Special voltages (IEC 38) - Surface treatments

ACCESSORIES - Inlet and/or inline filters - Additional inlet/outlet silencers - Safety valves - Flow converting device - Optional connectors

Dimensions in inches. Dimension for reference only.

16 REGENERATIVE BLOWERS - PRESSURE

Page 17: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

CAPA

CITY

A

BSO

RBED

PO

WER

TE

MPE

RATU

RE

INCR

EASE

SCL K04 / K05 / K06

TD SERIES 1/2 -6 SN 1931

60 Hz

5 1/2

4

0

20

40

60

80

100

120

140

160

200

In W

G

0 50 100 150 200 250 Scfm

K06-TD

3 5 1/2

7 1/2

10

3

2

K04-TD K05-TD 1

2

4

5

6

0

3

7

p

psig

0

20

40

60

80

100

120

140

In W

G

160

180

240

200

K05-TD K06-TD K04-TD

3

2

5 1/2

4

3

6 1/4

5 1/2

Scfm 0 50 100 150 200

50 Hz

8 1/3

1

2

4

5

6

0

3

7

8

p

psig

60 Hz

0

20

40

60

80

100

120

140

160

In W

G 200

K06-TD

0 1 2 3 4 5 6 8 10 Hp 7 9

K04-TD

K05-TD

1

2

4

5

6

0

3

7

p

psig

K05-TD K06-TD

K04-TD

50 Hz

0 1 2 3 4 5 6 7 8 Hp 10 11 0

20

40

60

80

100

120

140

180

In W

G

160

240

1

2

4

5

6

0

3

7

8

p

psig

60 Hz

0

20

40

60

80

100

120

140

200

In W

G

160

0 20 40 60 80 100 120 140 160 180 °F

K05-TD

K06-TD

K04-TD

1

2

4

5

6

0

3

7

p

psig

0

20

40

60

80

100

120

140

240

In W

G

160

0 20 40 60 80 100 120 140 160 180 °F

K05-TD

K04-TD

K06-TD

50 Hz

180

1

2

4

5

6

0

3

7

8

p

psig

Curves refer to air at 68°F temperature and 29.92 Hg atmospheric pressure (abs) measured at inlet port. Values for flow, power consumption and temperature rise +/-10% tolerance. Data subject to change without notice.

In

REGENERATIVE BLOWERS - PRESSURE 17

Page 18: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Model Maximum

flow Scfm

Installed power

Hp

Maximum differential pressure

∆∆∆ ( In WG )

Noise level Lp dB (A)

(1)

Overall dimensions

H Weight

60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm Inches Lbs

K07-TD 296 245 7 ½ 7 ½ 90 105 80.9 78.9 23.76 194.0 10 10 135 150 81.2 79.2 23.76 202.8 15 15 225 241 81.8 79.8 24.55

K08-TD 368 305 7 ½ 7 ½ 58 75 80.1 78.1 23.76 202.16 10 10 95 110 80.4 78.4 23.76 210.98 15 15 170 185 81.5 79.5 24.55 228.62

K09-TD 467 387 15 15 105 125 82.7 80.7 25.81 222.66 20 20 160 180 83.0 81.0 29.92 347.22 25 25 220 240 83.3 81.3 30.79 380.29

K10-TD 571 473 15 15 85 100 86.6 84.6 25.81 271.17 20 20 130 150 86.9 84.9 29.92 351.63 25 25 180 200 87.2 85.2 30.79 384.70

K11-TD 642 532 20 20 90 115 87.4 85.4 31.38 392.64 25 25 130 155 87.9 85.9 31.38 425.71

K12-TD 716 593 25 25 85 140 88.2 86.2 31.50 423.50 30 30 120 190 88.7 86.7 31.50 429.0

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.

Model a b c d d1 e f G I1 z

K07-TD 16.69 18.94 10.59 3.23 7.56 18.43 17.24 3”NPT 7.36 3.05 0.51 11.81 13.78 25.55 15.43 0.98 5.39 0.20 M8 11.61 18.94 12.56 10.24 0.63

K08-TD 17.99 19.61 10.59 3.23 7.56 18.82 17.64 3”NPT 7.36 3.05 0.51 11.81 13.78 25.55 15.43 0.98 5.39 0.20 M8 12.20 18.94 12.56 10.24 0.63

K09-TD 19.37 22.09 12.4 3.78 8.86 20.00 18.82 4”NPT 8.66 3.58 0.51 11.81 13.78 29.33 17.91 0.98 7.83 0.20 M8 14.17 21.89 14.65 11.89 0.63

K10-TD 20.31 22.56 12.4 3.78 8.86 20.00 18.82 4”NPT 8.66 3.58 0.51 11.81 13.78 29.33 17.91 0.98 7.83 0.20 M8 14.17 21.89 14.65 11.89 0.63

K11-TD 21.26 23.70 13.07 3.54 9.13 21.18 20.00 4”NPT 9.53 3.94 0.51 11.81 13.78 30.12 18.50 0.98 8.03 0.20 M8 15.35 21.89 15.24 12.76 0.63 K12-TD 21.57 23.81 13.07 3.54 9.13 21.18 20.00 4”NPT 9.53 3.94 0.51 11.81 13.78 30.23 18.50 0.98 8.03 0.20 M8 15.35 21.89 15.24 12.76 0.63

45°

q

d1

w

y

I1

d

b

e f

a

I2 G

c

s

3x120° øu

q

G

o

p1 H

p2 x

z

t

n r øm

SCL K07 / K08 / K09 / K10 / K11 / K12TD SERIESSN 1830-11 1/2

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories ailable on request. - Ambient temperature from +5° to +104°F. - Specifications subject to change without notice.

TECHNICAL CHARACTERISTICS - Aluminium alloy construction - Smooth operation - High efficiency impeller - Maintenance free - Mountable in any position - Recognized TEFC - cURus motor - G1/8” female thread on both suction

and discharge silencer port flanges

OPTIONS - Special voltages (IEC 38) - Surface treatments

ACCESSORIES - Inlet and/or inline filters - Additional inlet/outlet silencers - Safety valves - Flow converting device - Optional connectors

Dimensions in inches. Dimension for reference only.

G 1/8”

G 1/8”

p

I2 m n o p1 p2 q r s t u w x y

18 REGENERATIVE BLOWERS - PRESSURE

220.5

av

Page 19: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

CAPA

CITY

A

BSO

RBED

PO

WER

TE

MPE

RATU

RE IN

CREA

SE

SCL K07 / K08 / K09 / K10 / K11 / K12TD SERIESSN 1830-11 2/2

Curves refer to air at 68° F temperature and 29.9 Hg atmospheric pressure (abs) measured at inlet port. Values for flow, power consumption and temperature rise: +/-10% tolerance. Data subject to change without notice.

0

1

2

3

4

5

6

7

8

9

p p

sig

K10 -TD

0

20

40

60

80

100

120

140

160

180

200

260

0 20 40 60 80 100 120 140 °F

In W

G

K07-TD

K08-TD

K09-TD

K11 -TD

0

1

2

3

4

5

6

7

8

9

p p

sig

Scfm

15

20

25

100 200 300 400 500 600 700

100

120

140

160

180

200

220

260

0

20

40

60

80

In W

G

7 1/2

10

15

K07-TD

K08-TD

7 1/2

10

15

K09-TD

15

20

25

K10 -TD

K11 -TD

25

20

800

60 Hz

25

30

0

1

2

3

4

5

6

7

8

9

p p

sig

K10 -TD

0

20

40

60

80

100

120

140

160

180

200

260

0 5 10 15 20 Hp

In W

G

K08-TD

K07-TD

25

K09-TD K11 -TD

30

K12 -TD

K12 -TD

60 Hz

60 Hz

K12 -TD

0

1

2

3

4

5

6

7

8

9

10

p p

sig

0

1

2

3

4

5

6

7

8

9

10

p p

sig

0 20

40 60 80

100

120 140 160

180 200

220

280

0 20 40 60 80 100 120 140 160 180 °F

50 Hz

In W

G

K10 -TD

K07-TD

K08-TD

K09-TD

K11 -TD

0

1

2

3

4

5

6

7

8

9

10

p p

sig

K10 -TD

0

20

40

60

80

100

120

140

160

180

200

220

240

280

0 100 200 300 400 500 600 Scfm

In W

G

K08-TD

K07-TD K09-TD K11 -TD

15

20

7 1/2

10

15

7 1/2

10

15

15

20

25

25

20

25

700

25

30

K12 -TD

50 Hz

Hp

K12 -TD

K10 -TD

0 20 40 60 80

100

120 140 160

180 200 220

280

0 5 10 15 20

In W

G

K08-TD

K11-TD

25

K07-TD K09-TD

K12-TD

50 Hz

30

2 In

REGENERATIVE BLOWERS - PRESSURE 19

Page 20: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

STANDARD FEATURES - Low weight cast aluminum construction. - Quiet operation with integral inlet and

outlet muffling. - Recognized TEFC - cURus motor. - High efficiency / low noise impeller

design. - No lubrication / maintenance required. - Allowed ambient: +5 °F to +104 °F. - Mountable in any plane.

OPTIONS - Special voltages. - Surface treatment or plating. - Gas tight sealing. - Special designs available.

ACCESSORIES - Inlet and/or inline filters. - Additional inlet/outlet silencers. - Safety valves. - Flow converting devices. - Optionals connectors

SCL 06

SN 2673-1 1/2

Dimensions in inches. Dimension for reference only.

- For proper use, the blower should be equipped with inlet filt- Ambient temperature rom +5° to +104°F. - Specifications subject to change without notice.

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.

Model Maximum

flow Scfm

Installed power

Hp

Maximum differential pressure

p ( In WG)

Noise level Lp dB (A)

(1)

Overall dimensions

H Weight

60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm Inches Lbs

1/3 - 36 - 58.7 - 10.60 18.30 06 39 32 1/2 1/2 52 36 59.0 58.0 10.60 18.50

“P” version

1”NPT8.6

3.150.59 1.38

7.68.7

7.102.95

ø 0.43H

1.06

M5

5.35 DIA

4.644.56

4.373.38

4.13

M5

06 SERIES

er and safety valve; other accessories available on request. f

20 REGENERATIVE BLOWERS - PRESSURE

Page 21: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Curves refer to air at 68°F temperature and 29.92 In HgValues for flow, power consumption and Data subject to change without notice.

ABS

ORB

ED P

OW

ER

TEM

PERA

TURE

INCR

EASE

SCL 06

SN 2673- 2/2

CAPA

CITY

In W

G

60

0

10

20

30

40

0 0.1 Hp0.2 0.3 0.4 0 5

60 Hz

0

1,0

2.0

p

psig

1.5

0,5

0

10

20

40

In W

G

30

0 Scfm10 20 30 40

50 Hz

1/2

p

psig

1.0

0

0.5

40

0 30 50 60 80 °F0

10

20

In W

G

60 Hz

20

30

10 40 70

60

90 1000

1,0

2.0

p

psig

1.5

0,5

In W

G

0

10

20

40

30

Hp

50 Hz

0 0 05 0 1 0 1 5 0 2 0 30.25

p

psig

p

ps

ig

1.0

0

0.5

40

0

10

20

In W

G

30

0 30 50 60 80 °F

50 Hz

2010 40 70

1.0

0

0.5

p

psig

p

ps

ig

p

psig

0

1.0

2.0

1.5

0.5

Scfm0

10

20

30

40

50

60

In W

G

0 10 20 30 40

60 Hz

1/2

1/3

06 SERIES

. . . . ..

atmospheric pressure (abs) measured at inlet port.

REGENERATIVE BLOWERS - PRESSURE 21

temperature rise: +/-10% tolerance.

1

Page 22: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Model Maximum

flow Scfm

Installed power

Hp

Maximum differential pressure

∆p ( In WG)

Noise level Lp dB (A)

(1)

Overall dimensions

H Weight

60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm Inches Lbs

1/3 1/3 60 65 63.7 61.7 12.20 21.80 10DL 21 18

1/2 1/2 96 73 64.0 62.0 12.76 23.50 3/4 3/4 98 105 63.7 61.7 14.25 32.50 15DH 35 29 1 1 120.5 120.5 64.0 62.0 15.75 40.00

SCL 10DL / 15DH

SN 2197-3 1/2

STANDARD FEATURES - Low weight cast aluminum construction. - Quiet operation with integral inlet and outlet

muffling. - Recognized TEFC - cURus motor. - High efficiency / low noise impeller design. - No lubrication / maintenance required. - Allowed ambient: +5 °F to +104 °F. - Mountable in any plane.

OPTIONS - Remote drive models (belt or coupling). - Special voltages. - Surface treatment or plating. - Gas tight sealing. - Special designs available.

ACCESSORIES - Inlet and/or inline filters. - Additional inlet/outlet silencers. - Safety valves. - Flow converting devices. - Optionals connectors

Model a b c d e f G I m n o r s

10DL 8.66 10.08 9.06 0.91 8.27 7.09 1/2" NPT 2.28 0.35 4.72 5.67 3.54

15DH 9.84 11.26 10.16 1.18 8.27 7.09 3 4"NPT 2.52 0.35 4.72 5.67 4.72 0.10

d

G

rnoH

l

a

øm fe

b

c

s

Dimensions in inches. Dimension for reference only.

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request. - Ambient temperature from +5° to +104°F. - Specifications subject to change without notice.

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.

DH SERIES

.

0.10

22 REGENERATIVE BLOWERS - PRESSURE

/

Page 23: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Curves refer to air at 68°F temperature and 29.92 In Hg atmospheric pressure (abs) measured at inlet port. Values for flow, power consumption and temperature rise: +/-10% tolerance. Data subject to change without notice.

ABS

ORB

ED P

OW

ER

TEM

PERA

TURE

INCR

EASE

SCL 10DL / 15DH

SN 2197- 2/2

CAPA

CITY

p

psig

0

1

2

3

4

5

p

psig

0

1

2

3

4

5

Hp0 0,2 0,4 0,6 0,8 1

In W

G

0

20

40

60

80

100

140

10DL

15DH

50 Hz

p

psig

0

1

2

3

4

5

0

p

psig

1

2

3

4

5

0

20

40

60

80

100

120

140

In W

G

0 Scfm10 20 40 30

60 Hz

1

3/41/2

10DL

15DH

In W

G

0

20

40

60

80

100

140

0 0,2 Hp0,4 0,6 0,8 1

60 Hz

10DL 15DH

p

psig

0

1

2

3

4

5

p

psig

1

2

3

4

5

0

1/2

0

20

40

60

80

100

120

140

In W

G

0 Scfm10 20 30 40

50 Hz

1

3/4

15DH

10DL

0 20 40 60 80 100 °F0

20

40

60

80

100

140

In W

G

15DH

10DL

50 Hz

°F0

20

40

60

80

100

140

In W

G

0 20 40 60 80 100

60 Hz 15DH

10DL

1/3

1/2

0

20

40

60

80

100

120

140

In W

G

0 Scfm10 20 30 40

50 Hz

1

3/4

15DH

10DL

1/3

DH SERIES

REGENERATIVE BLOWERS - PRESSURE23

3

Page 24: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request. - Ambient temperature from +5° to +104°F. - Specifications subject to change without notice.

Model Maximum

flow Scfm

Installed power

Hp

Maximum differential pressure

∆p ( In WG)

Noise level Lp dB (A)

(1)

Overall dimensions

H Weight

60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm Inches Lbs

41 1 ½ 1 ½ 150 150 68.0 65.0 13. 47.30 2 2 140 161 69.7 67.7 15.36 58.30

30DH 70 61 3 - 191 - 70.0 68.0 15.36 64.90 3 3 151 156 74.7 71.7 16.93 75.00

40DH 98 85 4 4 201 201 75.0 72.0 16.93 83.80

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.

SCL R20-MD / 30DH / 40DH

SN 2464-3 1/2

STANDARD FEATURES - Low weight cast aluminum construction. - Quiet operation with integral inlet and outlet

muffling. - Recognized TEFC - cURus motor. - High efficiency / low noise impeller design. - No lubrication / maintenance required. - Allowed ambient: +5 °F to +104 °F. - Mountable in any plane.

OPTIONS - Remote drive models (belt or coupling). - Special voltages. - Surface treatment or plating. - Gas tight sealing. - Special designs available.

ACCESSORIES - Inlet and/or inline filters. - Additional inlet/outlet silencers. - Safety valves. - Flow converting devices. - Optionals connectors

Dimensions in inches. Dimension for reference only.

Model a b c d e f G I m n o p1 q r s t u z

11.22 12.20 6.57 1.77 8.27 1” ¼ NPT 30DH 12.60 13.66 7.36 2.09 10.63 9.64 1” ½ NPT 4.13 7.28 9.25 6.54 0.71 2.17 0.79 M6 7.09 0.67 40DH 13.78 14.57 7.68 2.09 10.63 9.65 1” ½ NP 4.13 7.28 9.25 7.32 0.71 2.17 0.79 M8 8.86 -

sl

G

d

c

a

fe

b

r

øm

p1

o

nq

H

3x120° øu

t

z

DH SERIES

T 11

0. 78 M6 5.91 -

24 REGENERATIVE BLOWERS - PRESSURE

3.54 0.40 5.90 7.68 .5 0.71 1.77 130R2 -MD

34 860R2 -MD

9 5 . 00.390.39

Page 25: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Curves refer to air at 68°F temperature and 29.92 In Hg atmospheric pressure (abs) measured at inlet port. Values for flow, power consumption and temperature rise: +/-10% tolerance. Data subject to change without notice.

CAPA

CITY

A

BSO

RBED

P

TEM

PERA

TURE

INCR

EASE

SCL R20-MD / 30DH / 40DH

SN 2464- 2/2

p

psig

0

1

2

3

4

5

6

7

0

20

40

60

80

100

120

140

160

180

220

0 Scfm

In W

G

20 40 60 80 100 120

60 Hz

3

2

30DH

20

3

4

40DH

p

psig

0

1

2

3

4

5

6

7

In W

G

0

20

40

60

80

100

120

140

160

220

Hp

50 Hz

30DH

0 0.5 1 1 5 2 2 5 3 3 5 4

40DH

p

psig

0

1

2

3

4

5

6

7

0

20

40

60

80

100

120

140

160

220

0 20 40 60 80 100 120 140 160 180 °F

In W

G 50 Hz

30DH

40DH

p

psig

0 1

2

3

4

5

6

7

In W

G

0

20

40

60

80

100

120

140

160

220

0 0.5 1 Hp

60 Hz

1.5 2 2.5 3 3.5 4

30DH 40DH

p

psig

0 1

2

3

4

5

6

7

0

20

40

60

80

100

120

140

160

220

0 20 40 60 80 100 120 140 160 180 °F

In W

G 60 Hz

30DH 40DH

p

psig

0

1

2

3

4

5

6

7

0

20

40

60

80

100

120

140

160

180

220

0 Scfm

50 Hz

In W

G

20 40 60 80 100

1 1/2

30DH

2

4

3

40DH

DH SERIES

. . .

REGENERATIVE BLOWERS - PRESSURE25

OW

ER

1 1/2

R -MD R20-MD

R20-MD

R20-MD

R20-MD R20-MD

3

Page 26: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

TECHNICAL CHARACTERISTICS - Aluminium alloy construction - Smooth operation - High efficiency impeller - Maintenance free - Mountable in any position OPTIONS - Special voltages (IEC 38) - Surface treatments ACCESSORIES - Inlet and/or inline filters - Additional inlet/outlet silencers - Safety valves - Flow converting device - Optional connectors

Model Maximum

flow Scfm

Installed power

Hp Size

Maximum differential pressure

Dp ( In WG )

Noise level Lp dB (A)

(1) Weight

(2) 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz Lbs 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm GOR GVR

3/4 NEMA 56C 64 62.0 K03-MS 52 43

1 NEMA 56C 80 60

62.3 60.0 22.00 17.60

1 ½ NEMA 56C 58 80 64.8 62.8 2 NEMA 56C 85 65.0 K04-MS 98 81 3 NEMA 56C 100

90 65.2

63.0 27.60 22.00

2 NEMA 143-5TC 52 70 70.5 68.5 NEMA 143-5TC

35.00 28.003

NEMA 182-4TC 90 10 70.8 68.8 K05-MS 156 129

5 NEMA 182-4TC 130 120 71.1 69.1 34.50 27.00

NEMA 143-5TC 46.00 38.403

NEMA 182-4TC 50 65 73.0 71.0

5 NEMA 182-4TC 85 110 73.6 71.6 K06-MS 216 179

7 ½ NEMA 182-4TC 140 135 73.9 71.9

40.80 38.00

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744. (2) Value is refered to weight of the machine without electric motor.

SCL K03 / K04 / K05 / K06SERIES - GOR/GVR RANGE

SN 2580-1 1/2

- For proper use, the blower should be equipped with inlet filter - Ambient temperature from +5° to +104°F. - Specifications subject to change without notice.

For dimensions, please refer to drw: -- GG OO RR range: SS II 11 885522 -- GG VVRR range: SS II 11 994466

GOR Range GVR Range

SCL Kxx-MS GOR-A SCL Kxx-MS GOR-C

1

and safety valve; other accessories available on request.

26 REGENERATIVE BLOWERS - PRESSURE

MS

Page 27: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

CAPA

CITY

A

BSO

RBED

PO

WER

TE

MPE

RATU

RE IN

CREA

SE

SCL K03 / K04 / K05 / K06SERIES - GOR/GVR RANGE

SN 2580-1 2/2

Curves refer to air at 68°F temperature and 29.92 In HgValues for flow, power consumption and emperature rise: +/-10% tolerance. Data subject to change without notice.

K05-MS K06-MS K04-MS K03-MS

0

20

40

60

80

100

120

160

In W

G

3

3/4

1

1 1/2

2

3

2

5

3

5

7 1/2

0 50 100 150 200 250 Scfm

60 Hz

140

0

1

2

3

4

5 p

psig

K06-MS

K05-MS

K04-MS

K03-MS

0

20

40

60

80

100

160

In W

G

120

0 1 2 3 4 5 6 7 Hp

60 Hz

0

1

2

3

4

5

p

psig

0 20 40 60 80 100 120 140 °F

0

20

40

60

80

100

160

In W

G

K06-MS

K04-MS

K03-MS

K05-MS 120

60 Hz

0

1

2

3

4

5

p

psig

0

1

2

3

4

5

p

psig

In W

G

0

20

40

60

80

100

120

140

160

0 50 100 150 200 Scfm

50 Hz

5

3

3

7 1/2

5

1 1/2

2

3/4

2

K03-MS K04-MS K05-MS K06-MS

0

1

2

3

4

5

p

psig

In W

G

0

20

40

60

80

100

120

160

0 1 2 3 4 5 6

50 Hz

Hp

K05-MS

K06-MS

K04-MS

K03-MS

0

1

2

3

4

5

p

psig

0 20 40 60 80 100 120 140 160 180 200 °F

In W

G

0

20

40

60

80

100

120

16050 Hz

K05-MS K06-MS

K04-MS

K03-MS

atmospheric pressure (abs) measured at inlet port. t

REGENERATIVE BLOWERS - PRESSURE27

MS

Page 28: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Model Maximum

flow Scfm

Installed power

Hp Size

Maximum differential pressure

∆p ( In WG )

Noise level Lp dB (A)

(1)

Weight (2)

60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm Lbs

5 NEMA 182-4TC 70 86 79.0 77.0 110.5 NEMA 182-4TC 110.5

7 ½ NEMA 213-5TC

130 79.3 110.5

K07-MS 294 243

10 NEMA 213-5TC 140

79.6 77.3

110.5

5 NEMA 182-4TC 38 52 79.7 77.7 127.0 NEMA 182-4TC 127.0

7 ½ NEMA 213-5TC

90 80.0 78.0 127.0

10 NEMA 213-5TC 115 125 80.3 78.3 127.0 NEMA 213-5TC 127.0

K08-MS 381 316

15 NEMA 254-6TC

170 160 80.6 78.6 130.6

NEMA 182-4TC 133.4 7 ½

NEMA 213-5TC 50 63 80.2 78.2

133.4 10 NEMA 213-5TC 80 95 80.5 78.5 133.4

NEMA 213-5TC 133.4 15

NEMA 254-6TC 140 155 81.0 79.0

137.0

K09-MS 471 390

20 NEMA 254-6TC 180 170 81.3 79.3 137.0

NEMA 182-4TC 147.3 7 ½

NEMA 213-5TC 30 50 80.1 78.1

147.3 10 NEMA 213-5TC 60 80 80.5 78.5 147.3

NEMA 213-5TC 147.3 15

NEMA 254-6TC 110 135 81.0 79.0

151.0 20 NEMA 254-6TC 160

K10-MS 556 460

25 NEMA 284-6TSC 200 190

81.6 79.4

147.3

10 NEMA 213-5TC 40 53 82.0 80.0 170.0 NEMA 213-5TC 170.0

15 NEMA 254-6TC

80 97 82.4 80.4 176.4

20 NEMA 254-6TC 125 140 82.7 80.7 176.4 25 NEMA 284-6TSC 160 170.0

K11-MS 650 539

30 NEMA 284-6TSC 200 190

86.0 83.6

170.0

NEMA 213-5TC 177.7 15

NEMA 254-6TC 52 90 82.9 80.9

184.1 20 NEMA 254-6TC 85 130 83.2 81.2 184.1 25 NEMA 284-6TSC 120 30 NEMA 284-6TSC 150 177.7

K12MS 726 602

40 NEMA 324-6TSC 180 170

86.9 84.1

193.2

TECHNICAL CHARACTERISTICS - Aluminium alloy construction - Smooth operation - High efficiency impeller - Maintenance free - Mountable in any position

OPTIONS - Special voltages (IEC 38) - Surface treatments

ACCESSORIES - Inlet and/or inline filters - Additional inlet/outlet silencers - Safety valves - Flow converting device - Optional connectors

- For proper use, the blower should be equipped with inlet filter - Ambient temperature from +5° to +104°F.

- Specifications subject to change without notice. (1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744. (2) Value is refered to weight of the machine without electric motor

SCL K07 / K08 / K09 / K10 / K11 / K12SERIES - GOR/GVR RANGE

SN 2134-3 1/2

GOR Range

SCL Kxx-MS GOR-C

SCL Kxx-MS GOR-A SCL Kxx-MS GOR-B

GVR Range

For dimensions, please refer to drw: GG OO RR range: SS II 11 887733 GG VVRR range: SS II 11 992200

68

81.4

86.1

85.6

86.5

170

151.0

177.7

28 REGENERATIVE BLOWERS - PRESSURE

and safety valve; other accessories available on request.

MS

Page 29: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Curves refer to air at 68°F temperature and 29.92 In Hg atmospheric pressure (abs) measured at inlet port. Values for flow, power consumption and Data subject to change without notice.

CAPA

CITY

A

BSO

RBED

PO

WER

TE

MPE

RATU

RE IN

CREA

SE

SCL K07 / K08 / K09 / K10 / K11 / K12SERIES - GOR/GVR RANGE

SN 2134-3 2/2

0

1

2

3

4

5

6

7

K11-MS

K08-MS

K09-MS K10-MS

K07-MS

60 Hz

0

20 40 60 80

100 120 140 160

In W

G

220

Hp 0 10 15 25 305 20

K12-MS

0

20

40

60

80

100

120

140

160

180

In W

G

220

0 100 200 300 400 Scfm700 500 600

K08-MS

K09-MS K07-MS

K10-MS

15

10

10

20 25

20

15

20

7 1/2

10

7 1/2

10

K11-MS

5 7 1/2

15

15

5

7 1/2

K12-MS

25

20

15

50 Hz

0

1

2

3

4

5

6

7

0

20

40

60

80

100

120

220

In W

G

140

160

Hp0 10 15 255 20

K07-MS

K11-MS

K08-MS K10-MS K12-MS

K09-MS

50 Hz

0

1

2

3

4

5

6

7

0

1

2

3

4

5

6

7

0

20

40

60

80

100

120

140

160

220

In W

G 50 Hz

K09-MS

K12-MS

K08-MSK10-MS

K11-MS

0 20 40 60 80 100 120 140 160 180 °F

K07-MS

0

1

2

3

4

5

6

7

K09-MS

K07-MS

K08-MS

K10-MS

K11-MS

0 20 40 60 80 100 120 140 160 °F 180

0 20

40

60

80

100

120

140

In W

G

160

220 60 Hz

K12-MS

0

1

2

3

4

5

6

7

0

20

40

60

80

100

120

140

180

In W

G

160

220

400 100 200 300 500 Scfm 700 8000 600

K08-MS K07-MS K09-MS

K10-MS

10 15

5

7 1/2

10

5

7 1/2

10

20

15

7 1/2

10

15

20

25 30

25

20

15

10

K11-MS K12-MS

15

20

30

40

60 Hz

7 1/2

25

temperature rise: +/-10% tolerance.

p

psig

p

psig

p

psig

p

psig

p

psig

p

psig

REGENERATIVE BLOWERS - PRESSURE29

MS

Page 30: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request. - Ambient temperature from +5° to +104°F. - Specifications subject to change without notice.

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744. (2) Value is refered to weight of the machine without electric motor.

SCL K05 / K06

SN 2686-1 1/2

For dimensions, please refer to drw: -- GG OO RR range: SS II 2211 2233 -- GG VVRR range: SS II 2211 3355

Model Maximum

flow m³/h

Installed power

Hp Size

Maximum differential pressure

∆p ( in WG )

Noise level Lp dB (A)

(1)

Weight (2)

60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz Lbs 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm GOR GVR

5.0 60 85 75.5 73.5 K05-TS 290 241 7.5

NEMA 182-4TC100 110 77.5 75.5

72.75 68.35

7.5 55 77 77.5 75.5 10 80 110 77.8 75.8 K06-TS 400 331

15

NEMA 213-5TC

130 120 78.4 76.4

112.45 108.00

TECHNICAL CHARACTERISTICS - Aluminium alloy construction - Smooth operation - High efficiency impeller - Maintenance free - Mountable in any plane - G1/8'' female thread on both suction and discharge silencer port flanges. OPTIONS - Special voltages (IEC 38) - Surface treatments

SCL Kxx-TS GOR-C

G 1/8”

GVR RangeGOR Range

G 1/8”

SCL Kxx-TS GOR-A SCL Kxx-TS GOR-B SCL Kxx-TS GOR-C

ACCESSORIES

- Inlet and/or inline filters - Additional inlet/outlet silencers - Safety valves - Flow converting device - Optional connectors

30 REGENERATIVE BLOWERS - PRESSURE

SERIES RANGE TS - GOR/GVR

Page 31: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

SCL K05 / K06SERIES RANGE

SN 2686- 2/2

CAPA

CITY

A

BSO

RBED

PO

WER

TE

MPE

RATU

RE IN

CREA

SE

Curves refer to air at 68°F temperature and 29.92 In Hg atmospheric pressure (abs) measured at inlet port. Values for flow, power consumption and Data subject to change without notice.

K05-TS

K06-TS

0 20 40 60 80 °F 0

20

40

60

140

In W

G

60 Hz

K06-TS

50 Hz

0 20 40 80 140 °F 60 100 120

K05-TS

80

100

100 1200

20

40

60

80

120

0

1

2

3

4

5

0

1

2

3

4

5

p

psig

p

psig

p

psig

60 Hz

0

20

40

60

140

0 1 2 3 4 5 6 7 8 Hp

In W

G

9 10

K05-TS

K06-TS

0

1

2

3

4

5

80

100

60 Hz

In W

G

0

20

40

60

140

0 100 200 300 400 Scfm

K05-TS

5

K06-TS

7 1/2

0

1

2

3

4

5

80

100

120

7 1/2

15

10

50 Hz

In W

G

0

20

40

60

140

0 100 200 300 400 Scfm

K05-TS

5

K06-TS

7 1/2

0

1

2

3

4

5

80

100

120

7 1/2

15

10

50 150 250 350

p

psig

50 Hz

0

20

40

60

140

0 1 2 3 4 5 6 7 8 Hp

In W

G

9 10

K05-TS

K06-TS

0

1

2

3

4

5

80

100

100

140

11 12 13 14 15

500

p

psig

p

psig

temperature rise: +/-10% tolerance.

REGENERATIVE BLOWERS - PRESSURE 31

TS - GOR/GVR 1

Page 32: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Model Maximum

flow Scfm

Installed power

Hp Size

Maximum differential pressure

∆∆∆∆p ( In WG )

Noise level Lp dB (A)

(1)

Weight (2)

60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rp m

Lbs

NEMA 182-4TC 36 60 83.9 81.9 160.90 7 ½

NEMA 213-5TC 36 60 83.9 81.9 160.90

10 NEMA 213-5TC 90 84.2 82.2 160.90

NEMA 213-5TC 110 140 84.8 82.8 160.90 15

NEMA 254-6TC (3) 110 140 84.8 82.8 167.60

K07-TS 588 487

20 NEMA 254-6TC (3) 140 140 85.3 82.8 167.60

10 NEMA 213-5TC 37 64 80.9 78.9 172.00 NEMA 213-5TC 75 105 83.3 81.3 172.00

15 NEMA 254-6TC (3) 75 105 83.3 81.3 180.80

20 NEMA 254-6TC (3) 100 150 84.6 82.6 180.80

K08-TS 715 592

25 NEMA 284-6TSC (3) 140 150 86.0 82.6 174.20

NEMA 213-5TC 52 75 83.0 81.0 202.80 15

NEMA 254-6TC (3) 52 75 83.0 81.0 208.30 20 NEMA 254-6TC (3) 108 85.0 83.0 208.30 25 NEMA 284-6TSC (3) 110 145 87.0 85.0 205.00 30 NEMA 284-6TSC (3) 120 160 89.0 87.0 205.00

K09-TS 941 780

40 NEMA 324-6TSC (3) 150 160 91.0 87.0 220.50

NEMA 213-5TC 64 87.8 85.8 209.40 15

NEMA 254-6TC (3) 41 64 87.8 85.8 216.10

20 NEMA 254-6TC (3) 65 90 88.1 86.1 216.10

25 NEMA 284-6TSC (3) 80 110 88.4 86.4 211.60

30 NEMA 284-6TSC (3) 100 140 88.7 86.7 211.60

K10-TS 1093 906

40 NEMA 324-6TSC (3) 150 160 89.0 87.0 227.10

25 NEMA 284-6TSC 50 88 89.4 87.4 251.30 30 NEMA 284-6TSC 70 110 90.0 88.0 251.30 40 NEMA 324-6TSC (3) 100 155 90.6 88.6 269.00

K11-TS 1254 1039

50 NEMA 324-6TSC (3) 140 155 91.2 88.6 269.00

30 NEMA 284-6TSC 45 80 90.6 88.6 249.10

40 NEMA 324-6TSC (3) 70 120 91.2 89.2 266.80 K12-TS 1410 1168

50 NEMA 324-6TSC (3) 110 150 91.8 89.8 266.80

TECHNICAL CHARACTERISTICS - Aluminium alloy construction - Smooth operation - High efficiency impeller - Maintenance free - Mountable in any position - G1/8” female thread on both

suction and discharge silencer port flanges

OPTIONS - Special voltages (IEC 38) - Surface treatments

ACCESSORIES - Inlet and/or inline filters - Additional inlet/outlet silencers - Safety valves - Flow converting device - Optional connectors

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories a vailable on request.

- Ambient temperature from +5° to +104°F. - Specifications subject to change without notice.

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744. (2) Value is refered to weight of the machine without electric motor (3) Not applicable on SCL Kxx - GVR

For dimensions, please refer to drw: GG OO RR range: SS II 11 887799 GG VVRR range: SS II 11 888800

SCL K07 / K08 / K09 / K10 / K11 /K12TS SERIES - GOR/GVR RANGE

SN 2164-4 1/2

SCL Kxx-TS GOR-A

SCL Kxx-TS GOR-B

SCL Kxx-TS GOR-C

GOR RANGE

GVR RANGE

G 1/8”

G 1/8”

60

41

80

32 REGENERATIVE BLOWERS - PRESSURE

m 2900 rp

Page 33: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Curves refer to air at 68°F temperature and 29.92 In Hg atmospheric pressure (abs) measured at inlet . Values for flow, power consumption and temperature rise: +/-10% tolerance. Data subject to change without notice.

CAPA

CITY

A

BSO

RBED

PO

WER

TE

MPE

RATU

RE IN

CREA

SE

SCL K07 / K08 / K09 / K10 / K11 / K12 TS SERIES - GOR/GVR RANGE

SN 2164- 2/2

Scfm

K11 -TS

K08-TS

K09-TS

K10 -TS

K07-TS

Hp 0 10 20 30 40 50 0

20

40

60

80

100

120

140

180

In W

G

p

psig

0

1

2

3

4

5

6 60 Hz

K12 -TS

K07-TS

K09-TS

K12 -TS

K08-TS

K10 -TS

0

20

40

60

80

100

120

140

180

In W

G

0 20 40 60 80 100 120 140 160 ° F

60 Hz

p

psig

0

1

2

3

4

5

6

K11 -TS

K07-TS K11 -TS

K08-TS

K09-TS

K10 -TS

Hp 0 10 20 30 40

0

20

40

60

80

100

120

140

180

In W

G

p

psig

0

1

2

3

4

5

6

K12 -TS

50 Hz

0

1

2

3

4

5

6

p

psig

K07-TS

K10 -TS K08-TS

K11 -TS K09-TS

0 200 400 600 800 1000 1200 Scfm 0

20

40

60

80

100

120

140

160

180

In W

G

15

20

30 40

30

40

25

25 15

10

7 1/2 10

15

15

20

20

25

30

K12 -TS

30

40

50

50 Hz

p

psig

0

1

2

3

4

5

6

0 20 40 60 80 100 120 140 160 °F

K09-TS

K11 -TS

K10 -TS K08-TS

0

20

40

60

80

100

120

140

180

In W

G

K12 -TS

K07-TS

50 Hz

0

1

2

3

4

5

6

p

psig

0

20

40

60

80

100

120

140

180

In W

G

160

200 400 600 800 1000 1200 1400

K07-TS

K08-TS K10 -TS

K11 -TS K09-TS

20 25

20 15

10

15

40 40 50

30 25

20

15

20

25

30 40

30

25

7 1/2 10 15

1400

50

40

30

K12 -TS

60 Hz

REGENERATIVE BLOWERS - PRESSURE33

4

port

Page 34: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Model Maximum

flow Scfm

Installed power

Hp Size

Maximum differential pressure

∆p ( In WG )

Noise level Lp dB (A)

(1) Weight

(2) 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm Lbs

NEMA 56C 112.00 3

NEMA 143-5TC 68 87 73.5 71.5

112.00 5 NEMA 182-4TC 145 170 74.5 72.5 113.80

NEMA 182-4TC K07R-MD 129 107

7 ½ NEMA 213-5TC

250 260 75.0 73.0 113.80

5 NEMA 182-4TC 80 110 76.2 74.2 130.30 NEMA 182-4TC 130.30

7 ½ NEMA 213-5TC

160 185 76.6 74.6 130.30

10 NEMA 213-5TC 220 250 77.0 75.0 130.30

K08R-MD 168 139

15 NEMA 213-5TC 260 - 77.4 - 130.30

5 NEMA 182-4TC 50 78 76.9 74.9 138.50 NEMA 182-4TC

7 ½ NEMA 213-5TC

120 143 78.0 76.0 138.50

10 NEMA 213-5TC 190 210 79.5 77.5 138.50

K09-MD 221 183

15 NEMA 213-5TC 280 280 80.5 78.5 138.50

NEMA 182-4TC 7 ½

NEMA 213-5TC 85 110 79.9 77.9

152.40 10 NEMA 213-5TC 140 165 80.3 78.3 152.40

K10-MD 275 228

15 NEMA 213-5TC 245 280 81.4 79.4 152.40

10 NEMA 213-5TC 100 125 81.1 79.1 175.70 NEMA 213-5TC

15 NEMA 254-6TC

190 220 81.4 79.4 182.10

K11-MD 306 254

20 NEMA 254-6TC 270 280 81.7 79.7 182.10

NEMA 213-5TC 15

NEMA 254-6TC 100 180 82.3 80.3

189.80 20 NEMA 254-6TC 180 260 82.6 80.6 189.80

K12-MD 336 278

25 NEMA 284-6TSC 250 - 82.9 - 183.40

TECHNICAL CHARACTERISTICS - Aluminium alloy construction - Smooth operation - High efficiency impeller - Maintenance free - Mountable in any position

OPTIONS - Special voltages (IEC 38) - Surface treatments

ACCESSORIES - Inlet and/or inline filters - Additional inlet/outlet silencers - Safety valves - Flow converting device - Optional connectors

- For proper use, the blower should be equipped with inlet filter - Ambient temperature from +5° to +104°F. - Specifications subject to change without notice.

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744. (2) Value is refered to weight of the machine without electric motor

SCL K07R / K08R / K09 / K10 / K11 / K12MD SERIES - GOR/GVR RANGE

SN 2149-2 1/2

GOR Range

SCL Kxx-MD GOR-C

SCL Kxx-MD GOR-A

SCL Kxx-MD GOR-B

GVR Range

For dimensions, please refer to drw: GG OO RR range: SS II 11 9911 88 GG VVRR range: SS II 11 9911 99

34 REGENERATIVE BLOWERS - PRESSURE

138.50

113.80

183.40

125.40

175.70

and safety valve; other accessories available on request.

Page 35: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Curves refer to air at 68°F temperature and 29.92 In HgValues for flow, power consumption and temperature rise: +/-10% tolerance. Data subject to change without notice.

CAPA

CITY

A

BSO

RBED

PO

WER

TE

MPE

RATU

RE IN

CREA

SE

SCL K07R / K08R / K09 / K10 / K11 / K12MD SERIES - GOR/GVR RANGE

SN 2149- 2/2

Hp

∆p

psi

g

0 20 40 60 80

100 120 140 160

In W

G

180 200 220 240

320

0 8 10 16 20 4 14 2 6 12 18 0 1

2

3

4

5

6

7

8

9 10

11

K07R-MD

K08R-MD

K09-MD

K10-MD

K11-MD

K12-MD

22 24

60 Hz

0 20 40 60 80

140 160

320

In W

G

200 240

100 120

180 220

Hp0 842 6 10

∆p

psi

g

0

1

2

3

4

5

6

7

8

910

11

12 14 16 18

K07R-MD

K08R-MD

K09-MD

K10-MD K11-MD

K12-MD

50 Hz

020406080

100120140160

240

In W

G

180200220

320

0 20 40 60 80 100 120 140 160 180 °F

50 Hz

K10-MD

K07R-MD K11-MD

K09-MD K12-MD

∆p

psi

g

0

1

2

3

4

5

6

7

8

910

11

K08R-MD

∆p

psi

g

0

1

2

3

4

5

6

7

8

9

10

11

0 100 200 300 Scfm0

20 40 60 80

100

120

140

160

180

In W

G

320

200

220

240

260

280

50 Hz

K08R-MD

K09-MD K07R-MD

K10-MD

K11-MD

7 1/2

15

5

5

7 1/2

7 1/2

10

15 20

15

10

10

7 1/2

3 5

20

15

K12-MD

10

∆p

psi

g

0 1

2

3

4

5

6

7

8

9 10

11

0 20 40 60 80

100 120 140

In W

G

160

320

180 200 220 240

0 20 40 60 80 100 120 140 160 °F 180

K10-MD

K07R-MD

K09-MD

K08R-MD

60 Hz

K12-MD

K11-MD

Scfm

∆p

psi

g

0

1

2

3

4

5

6

7

8

9

10

11

0

20 K08R-MD K07R-MD

5 7 1/2

3 7 1/2

10

5

K09-MD K10-MD

5

7 1/2

60 Hz

400100 200 300 0

15 20

15

10

K11-MD

10

15 7 1/2 25

20

15

K12-MD

15

10

320

40

60

80

100

120

140

180

In W

G

160

240

220

200

260

280

atmospheric pressure (abs) measured at inlet port.

REGENERATIVE BLOWERS - PRESSURE35

2

Page 36: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

TECHNICAL CHARACTERISTICS - Aluminium alloy construction - Smooth operation - High efficiency impeller - Maintenance free - Mountable in any position - G1/8” female thread on both

suction and discharge silencer port flanges

OPTIONS - Special voltages (IEC 38) - Surface treatments

ACCESSORIES - Inlet and/or inline filters - Additional inlet/outlet silencers - Safety valves - Flow converting device - Optional connectors

- For proper use, the blower should be equipped wit h inlet filter and safety valve; other accessories a vailable on request. - Ambient temperature from +5° to +104° F. - Specifications subject to change without notice.

Model Maximum

flow Scfm

Installed power

Hp Size

Maximum differential pressure

∆∆∆∆p ( In WG )

Noise level Lp dB (A)

(1)

Weight (2)

60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm Lbs

K07-TD 296 245

7 ½ NEMA 182-4TC

90 130 80.9 78.9 156.50 NEMA 213-5TC

10 NEMA 213-5TC 135 185 81.2 79.2 156.50

15 NEMA 213-5TC

225 230

81.8 79.8

156.50 NEMA 254-6TC 160.90

20 NEMA 254-6TC 240 82.1 160.90

K08-TD 368 305

10 NEMA 213 -5TC 95 140 80.4 78.4 169.80

15 NEMA 213-5TC

170 220 81.5 79.5 169.00

NEMA 254-6TC 178.60 20 NEMA 254-6TC 220 240 82.3 80.3 178.60

K09-TD 467 387

15 NEMA 213-5TC

105 155 82.7 80.7 196.20

NEMA 254-6TC 201.70 20 NEMA 254-6TC 160 225 83.0 81.0 201.70 25 NEMA 284-6TSC 220

240 83.3 81.3 198.40

30 NEMA 284-6TSC 240 83.6 81.6 198.40

K10-TD 571 473

15 NEMA 213-5TC

85 130 86.6 84.6 202.80

NEMA 254-6TC 209.50

20 NEMA 254-6TC 130 180 86.9 84.9 209.50 25 NEMA 284-6TSC 180

240 87.2

85.2 205.00

30 NEMA 284-6TSC 200 87.5 205.00

40 NEMA 324-6TSC 240 87.8 220.50

K11-TD 642 532

20 NEMA 254-6TC 90 140 87.4 85.4 246.80

25 NEMA 284-6TSC 130 180 87.9 85.9 244.70 30 NEMA 284-6TSC 150

240 88.4

86.4 244.70

40 NEMA 324-6TSC 240 88.9 264.50

K12-TD 716 593

25 NEMA 284-6TSC 85 140 88.2 86.2 242.5 30 NEMA 284-6TSC 120 190 88.7 86.7 242.5 40 NEMA 324-6TSC 190 240 89,2 87.2 262.3 50 NEMA 324-6TSC 240 - 89.5 - 262.3

(1) Noise measured at 1 m distance with inlet and outlet ports piped, i accordance to ISO 3744. (2) Value is refered to weight of the machine without electric motor

For dimensions, please refer to drw:

SCL K07 / K08 / K09 / K10 / K11 / K12TD SERIES - GOR RANGE

SN 2179-3 1/2

G 1/8”

SI1971

36 REGENERATIVE BLOWERS - PRESSURE

n

Page 37: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Curves refer to air at 68°F temperature and 29.92 In Hg atmospheric pressure (abs) measured at inlet port. Values for flow, power consumption and temperature rise +/-10% tolerance. Data subject to change without notice.

CAPA

CITY

A

BSO

RBED

PO

WER

TE

MPE

RATU

RE IN

CREA

SE

SCL K07 / K08 / K09 / K10 / K11 / K12TD SERIES - GOR RANGE

SN 2179-

0 100 200 300 400 Scfm 500 600

K07-TD

K10-TD K08-TD

K11-TD K09-TD

15

15

10

10

20

20

25

15

15

20

25

0

20

40

60

80

100

120

140

160

180

In W

G

200

220

240

280

30

25 20

0

1

2

3

4

5

6

7

8

9

10

p p

sig

700

K12-TD

25

30

40

50 Hz

7 1/2

0

1

2

3

4

5

6

7

8

9

10

p p

sig

K07-TD K11 -TD

K08-TD

K09-TD

Hp 0 10 20 30

0 20 40 60

80 100

120

220

280

In W

G

140 160

180 200

K10 -TD K12 -TD

40

50 Hz

0

1

2

3

4

5

6

7

8

9

10

p p

sig

0

20

40 60

80

100

120

140

160 180

200 220

280

0 20 40 60 80 100 120 140 160 180 °F

In W

G

K08-TD

K07-TD

K11 -TD

K09-TD

K10 -TD

K12 -TD

50 Hz

K07-TD

K08-TD K10-TD

K09-TD

20 20 15

10

15

40 40 30 25

20

15 20

25 30

30 25

7 1/2 10

15

0

20

40

60

80

100

120

140

180

In W

G

160

200

220

240

260

300

100 200 300 500 Scfm 400 600 700

20

p

psig

0

1

2

3

4

5

6

7

8

9

10

800

25

30

40

50

K12 -TD

K11 -TD

60 Hz

0 20 40 60 80 100 120 140 160 °F 180

p

psig

0 1

2

3

4

5

6

7

8

9

10

K08-TD

K07-TD

K11 -TD

K09-TD

K10 -TD

0 20 40 60 80

100 120 140

200

In W

G

160 180

220 240

300

K12 -TD

60 Hz

0

20 40 60 80

100 120 140 160

In W

G

180 200 220 240

300

Hp 0 10 20 30 40

K11 -TD

K08-TD

K09-TD K07-TD

0 1

2

3

4

5

6

7

8

9

10

50

K10 -TD K12 -TD

60 Hz

p

psig

REGENERATIVE BLOWERS - PRESSURE37

3 2/2

Page 38: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Model Maximum

flow Scfm

Installed power

Hp Size

Maximum differential pressure

∆p ( In WG )

Noise level Lp dB (A)

(1) Weight

(2) 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm Lbs

25 - 260 - 85.9 30

NEMA 284-6TSC 220 330 88.2 86.2

354 K09-TT 423 351 40 NEMA 324-6TSC 330 - 88.5 - 363

30 NEMA 284-6TSC - 260 - 86.5 365 40 260 340 88.8 86.8 K10-TT 526 436 50

NEMA 324-6TSC 340 - 89.1 -

380

40 220 300 89.1 87.1 K11-TT 597 495 50

NEMA 324-6TSC 320 350 89.5 87.5

434

SCL K09 / K10 / K11TT SERIES - GOR RANGE

SN 2778-2 1/2

TECHNICAL CHARACTERISTICS - Aluminium alloy construction - Smooth operation - High efficiency impeller - Maintenance free - G1/8” female thread on both

suction and discharge silencer port flanges

OPTIONS - Special voltages (IEC 38) - Surface treatments

ACCESSORIES - Inlet and/or inline filters - Additional inlet/outlet silencers - Optional connectors

- For proper use, the blower should be equipped with inlet filt safety valve; other accessories available on request. - Ambient temperature from +5° to +104°F. - Specifications subject to change without notice.

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744. (2) Value is refered to weight of the machine without electric motor

G 1/8”

er and

38 REGENERATIVE BLOWERS - PRESSURE

Page 39: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Scfm

SCL K09 / K10 / K11TT SERIES - GOR RANGE

SN 2778- 2/2

- Curves refer to air at 68°F temperature and 29.92 In Hg atmospheric pressure (abs) measured at inlet port. - Values for flow, power consumption and temperature rise: +/-10% tolerance. - Data subject to change without notice.

CAPA

CITY

A

BSO

RBED

PO

WER

TE

MPE

RATU

RE IN

CREA

SE

p

psig

0

40

80

120

160

200

240

280

320

400

0 5 10 15 20 25 30 35 40 45 50 Hp

60 Hz

K10-TT

p

psig

0 1 2 3 4 5 6 7 8 9

10 11 12 13 14

In W

G

0

40

80

120

160

200

240

280

320

0 20 40 60 80 100 120 140 160 180 200 220 °F

60 Hz 400

p

psig

0 1 2 3 4 5 6 7 8 9

10 11 12 13 14

In W

G

0

40

80

120

160

200

240

280

320

400

200 300 400 500 600 700 Scfm

60 Hz

50

40

K10-TT

0 1

2

3

4

5

6

7

8

9

10

11

12

13

14

In W

G

p

psig

0 5 10 15 20 25 30 35 40 Hp

40

80

120

160

200

240

280

320

400 50 Hz

0

K10-TT

0

123456789

1011121314

In W

G

0 20 40 60 80 100 120 140 160 180 200 220 °F 0

40

80

120

160

200

240

280

320

400 50 Hz

K10-TT

p

psig

0123456789

1011121314

In W

G

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

0

40

80

120

160

200

240

280

320

400

In W

G

p

psig

K09-TT

K11-TT

K09-TT

K11-TT

K09-TT

30

40

K11-TT

40

50

K09-TT

K11-TT

K10-TT

K09-TT K11-TT

30

40

600300 400 500

50 Hz

K10-TT

30

25

K09-TT

K11-TT

40

50

200

REGENERATIVE BLOWERS - PRESSURE39

2

Page 40: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Model Maximum

flow cfm

Installed power

Hp

Maximum differential pressure

∆p ( In Hg )

Noise level Lp dB (A)

(1)

Overall dimensions

H Weight

60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm Inches Lbs

3/4 3/4 4.7 3.7 61.0 59.0 10.43 24.30 K03-MS 52 43 1 1 5.9 4.9 61.3 59.3 11.97 26.50

1 ½ 1 ½ 4.3 5.9 63.8 61.8 11.65 36.40 2 2 6.3 6.6 64.0 62.0 13.78 43.00 K04-MS 98 81 3 - 7.4 - 64.2 - 13.78 49.60 2 2 3.8 5.1 69.5 67.5 13.20 51.80 3 3 6.6 7.1 69.8 67.8 13.20 58.40 K05-MS 156 129 4 - 8.1 - 70.1 - 14.40 67.20 3 3 3.7 4.8 72.0 70.0 13.54 68.70 4 4 5.5 7.0 72.3 70.3 14.17 71.65

5 ½ 5 ½ 8.1 8.1 72.6 70.6 14.17 77.60 K06-MS 216 179

6 1/5 (2) - 9.6 - 72.9 - 14.45 77.60

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744. (2) No cURus motor

SCL K03 / K04 / K05 / K06

SN 1879-9 1/2

- For proper use, the blower should be equipped with inlet filter an - Ambient temperature rom +5° to +104°F. - Specifications subject to change without notice.

e

a

fIG

d

c

b

s

p1

o

Ømn r q

z

H

3x120°øu

t

Accessory

Model a b c d e f G I m n o p1 q r s t u z

K03-MS 9.49 10.55 5.79 1.69 9.06 8.07 1” ¼ NPT 3.39 0.39 3.27 5.59 8.07 0.71 2.95 0.16 M6 5.51 0.47 K04-MS 11.22 12.40 6.77 1.93 10.04 8.86 1"1/2

K05-MS 12.87 14.37 7.87 2.13 12.60 10.24 2” NPT 4.72 0.59 4.53 10.43 12.60 0.71 3.86 0.16 M8 7.87 0.75 K06-MS 14.80 15.47 8.07 2.13 12.80 11.42 0.59 5.51 10.71 13.15 0.71 3.35 0.16 M8 9.45 0.75

TECHNICAL CHARACTERISTICS - Aluminium alloy construction - Smooth operation - High efficiency impeller - Maintenance free - Mountable in any position - Recognized TEFC - cURus motor

OPTIONS - Special voltages (IEC 38) - Surface treatments

ACCESSORIES - Inlet and/or inline filters - Additional inlet/outlet silencers - Safety valves - Flow converting device - Optional connectors

Dimensions in inches. Dimension for reference only.

MS SERIES

4.02 0.47 3.74 6.73 8.74 0.71 2.76 0.16 M6 6.89 0.71 NPT

2 ” NPT 4.92

d safety valve; other accessories available on request. f

40 REGENERATIVE BLOWERS - VACUUM

Page 41: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

CAPA

CITY

A

BSO

RBED

PO

WER

TEM

PERA

TURE

INCR

ESA

SCL K03 / K04 / K05 / K06

SN 1879-9 2/2

Curves refer to air at 68° F temperature, measured at Values for flow, power consumption and Data subject to change without notice.

p

In H

g

0

1

2

3

4

5

6

7

8

9

10

2

3

4

K05-MS

0

20

40

60

80

100

120

140

0 50 100 150 200 250

In W

G 60 Hz

cfm

6 1/5

5 1/2

4

3

K06-MS K04-MS

1 1/2

2

3

K03-MS

3/4

1

0

1

2

3

4

5

6

7

8

9

10

p

In H

g

0

20

40

60

80

100

140

0 1 2 3 4 5 6 7 Hp

In W

G 60 Hz

K05-MS

K06-MS

K04-MS

K03-MS

p

In H

g

0

1

2

3

4

5

6

7

8

9

10

0 20 40 60 80 100 120 140 160 180 200 °F

0

20

40

60

80

100

140

In W

G 60 Hz

K06-MS

K04-MS K05-MS

K03-MS

p

In H

g

0

1

2

3

4

5

6

7

8

2

3

K05-MS

0

20

40

60

80

100

120

0 50 100 150 200 cfm

In W

G 50 Hz

5 1/2

3

K06-MSK04-MS

2

1 1/2

K03-MS

3/4

4

1

p

In H

g

0

1

2

3

4

5

6

7

8

0

20

40

60

80

120

In W

G

K05-MS

0 1 2 3 4 5 Hp

50 Hz

K06-MS

K04-MS

K03-MS

p

In H

g

0

1

2

3

4

5

6

7

8

0

20

40

60

80

120

0 20 40 60 80 100 120 140 160 180 200 °F

50 Hz

In W

G

K05-MSK04-MS

K03-MS

K06-MS

MS SERIES

SE

41REGENERATIVE BLOWERS - VACUUM

temperature rise: +/-10% tolerance. inlet port and 29.92 In Hg atmospheric backpressure (abs).

Page 42: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

TECHNICAL CHARACTERISTICS - Aluminium alloy construction - Smooth operation - High efficiency impeller - Maintenance free - Mountable in any position - Recognized TEFC - cURus motor

OPTIONS - Special voltages (IEC 38) - Surface treatments

ACCESSORIES - Inlet and/or inline filters - Additional inlet/outlet silencers - Safety valves - Flow converting device - Optional connectors

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request. - Ambient temperature from +5° to +104°F. - Specifications subject to change without notice.

Model Maximum

flow cfm

Installed power

Hp

Maximum differential pressure

Dp ( In Hg )

Noise level Lp dB (A)

(1)

Overall dimensions

H Weight

60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm Inches Lbs

K07-MS 294 243

4 4 3.7 4.6 77.7 75.7 15.45 103.00 5 ½ 5 ½ 5.6 6.3 78.0 76.0 15.45 107.10 7 ½ 7 ½ 9.6 8.9 78.3 76.3 18.37 145.70 10 - 11.1 - 78.6 - 18.37 154.50

K08-MS 381 316

5 ½ 5 ½ 2.9 3.8 78.8 76.8 15.45 115.70 7 ½ 7 ½ 5.0 6.6 79.1 77.1 18.37 154.30 10 10 8.5 9.2 79.4 77.4 18.37 163.10 15 - 11.1 - 79.7 - 19.15 184.00

K09-MS 471 390

7 ½ 7 ½ 3.7 4.6 79.3 77.3 18.84 166.50 10 10 5.9 7.0 79.6 77.6 18.84 175.10 15 15 10.3 10.4 80.1 78.1 19.63 196.20 20 - 11.1 - 80.4 - 23.74 269.00

K10 -MS 556 460

7 ½ 7 ½ 2.7 3.8 79.4 77.4 18.84 170.90 10 10 4.7 5.9 79.7 77.7 18.84 179.50 15 15 8.8 9.9 80.2 78.2 19.63 200.60 20 - 11.1 - 80.5 - 23.74 273.40

K11 -MS 650 539 10 10 2.9 3.9 82.0 80.0 19.04 194.90 15 15 6.0 7.1 82.5 80.5 19.83 216.00 20 20 11.1 10.4 83.0 81.0 23.94 288.80

K12 -MS 726 602 15 15 3.8 6.6 83.5 81.5 19.95 223.70 20 20 6.3 9.6 84.3 82.3 24.06 296.50 25 - 10.3 - 87.2 - 24.92 320.80

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3 744.

SCL K07 K08 / K09 / K10 / K11 / K12 SERIES MS -

SN 1810 1/2 -16

Dimensions in inches. Dimension for reference only.

Model a b c d e f G I m n o p1 q r s t u z

K07-MS 16.69 18.84 10.59 3.23 18.43 17.2 4 3” NPT 6.10 0.51 11.81 13.78 20.16 0.98 5.39 0.20 M8 11.61 0.63 K08-MS 17.99 19.61 10.59 3.23 18.82 17.64 3” NPT 6.10 0.51 11.81 13.78 20.16 0.98 5.39 0.20 M8 12.2 0.63 K09-MS 19.37 22.09 12.40 3.78 20.00 18.82 4” NPT 7.17 0.51 11.81 13.78 23.07 0.98 7.83 0.20 M8 14.17 0.63 K10 -MS 20.31 22.56 12.40 3.78 20.00 18.82 4” NPT 7.17 0.51 11.81 13.78 23.07 0.98 7.83 0.20 M8 14.17 0.63 K11 -MS 21.34 23.74 13.07 3.58 21.26 20.00 4” NPT 7.87 0.51 11.81 13.78 23.46 0.98 8.03 0.20 M8 15.35 0.63 K12 -MS 21.57 23.82 13.07 3.58 21.26 20.00 4” NPT 7.87 0.51 11.81 13.78 23.58 0.98 8.03 0.20 M8 15.35 0.51

Accessory

r q

p1 H

o

n

øm

3x120° øu

z

t

G

d

c b

e

f

I

a

s

42 REGENERATIVE BLOWERS - VACUUM

Page 43: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Curves refer to air at 68° F temperature, measured at inlet port and 29.92 In Hg atmospheric backpressure (abs). Values for flow, power consumption and temperature rise: +/ -10% tolerance.Data subject to change without notice.

CAPA

CITY

A

BSO

RBED

PO

WER

TE

MPE

RATU

RE IN

CRES

ASE

SCL K07 / K08 / K09 / K10 / K11 / K12 MS SER IES SN 1810-1 2/2 6

10

7 1/2

20

10

15

15

10

20

15

20

15

10

K07-MS

4

7 1/2 K10 -MS

7 1/2

K08-MS

10

K11 -MS

7 1/2

K09-MS

5 1/2

5 1/2

K12 -MS

0

20

40

60

80

100

120

140

160

0 100 200 300 400 500 600

In W

G

800 cfm 700

50 Hz 60 Hz

20

15

0

1

2

3

4

5

6

7

8

9

10

11

p

In

Hg

0

1

2

3

4

5

6

7

8

9

10

11

p

In

Hg

0

20

40

60

80

100

120

160

0 5 10 15 Hp

In W

G

20

50 Hz

K08-MS

K07-MS K11 -MS K09-MS

K10 -MS K12 -MS

0

1

2

3

4

5

6

7

8

9

10

11

p

In

Hg

0

20

40

60

80 100

120

160

0 20 40 60 80 100 120 140 160 °F

K10 -MS

K07-MS

K08-MS

K11 -MS

50 Hz

In W

G

K09-MS

K12 -MS

0

1

2

3

4

5

6

7

8

9

10

11

p

In

Hg

0

20

40

60

80

100

120

140

160

0 100 200 300 400 500 700 cfm

In W

G

600

K07-MS

K10 -MS K08-MS

K11 -MS K09-MS

K12 -MS

4

7 1/2

7 1/2

10

15 10

7 1/2

20

15

10

15

10

7 1/2

5 1/2

5 1/2

15

20

50 Hz

25

0

1

2

3

4

5

6

7

8

9

10

11

p

In

Hg

K07-MS

K10 -MS

0

20

40

60

80

100

120

160

0 5 10 15 20 Hp

In W

G

K08-MS

60 Hz

25

K11 -MS K09-MS K12 -MS

0

1

2

3

4

5

6

7

8

9

10

11

p

In

Hg

In W

G

0

20

40

60

80

100

120

160

0 20 40 60 80 100 120 140 160 180 200 °F

60 Hz K11 -MS

K08-MS

K07-MS K10 -MS

K09-MS

K12 -MS

43REGENERATIVE BLOWERS - VACUUM

Page 44: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Model Maximum

flow cfm

Installed power

Hp

Maximum differential pressure

p ( In Hg )

Noise level Lp dB (A)

(1)

Overall dimensions

H Weight

60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm Inches Lbs

K05-TS 290 241 3 3 2.2 3.3 71.6 69.6 17.45 85.98 4 4 3.4 5.1 73.1 71.1 18.64 89.29

5 ½ 5 ½ 5.3 6.6 75.1 73.1 18.64 93.70

K06-TS 400 331 5 ½ 5 ½ 2.7 4.0 76.8 74.8 18.98 104.72 7 ½ 7 ½ 4.0 4.8 77.1 75.1 22.60 141.09 10 10 6.3 6.8 77.4 75.4 22.60 149.91

SCL K05 / K06TS SERIES SN 192 1/2 6-6

- For proper use, the blower should be equipped with inlet filter and safety v alve; other accessories available on request.- Ambient temperature from +5° to +104°F. - Specifications subject to change without notice.

s G

e f I

d

c b

a

r o n

øm q

3x120°øu t

z H

p1

Model a b c d e f G I m n o p1 q r s t u z

K05-TS 12.87 16.61 10.16 3.03 15.91 14.72 3” NPT 5.91 0.51 11.81 13.58 24.96 0.98 1 2.91 0.16 M8 7.87 0.75 K06-TS 14.80 17.72 10.31 2.95 15.91 14.72 3” NPT 6.10 0.51 11.81 13.58 26.06 0.98 13.19 0.16 M8 9.45 0.75

Accessory

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.

TECHN ICAL CHARACTERISTICS - Aluminium alloy construction - Smooth operation - High efficiency impeller - Maintenance free - Mountable in any position - Recognized TEFC - cURus motor

OPTIONS - Special voltages (IEC 38) - Surface treatments

ACCESSORIES - Inlet and/or inline filters - Additional inlet/outlet silencers - Safety valves - Flow converting device - Optional connectors

Dimensions in inches. Dimension for reference only.

44 REGENERATIVE BLOWERS - VACUUM

Page 45: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

CAPA

CITY

A

BSO

RBED

PO

WER

TE

MPE

RATU

RE

INCR

EASE

SCL K05 / K06TS SERIESSN 192

2/2

6-6

Curves refer to air at 68° F temperature, measured at inlet port and 29.92 In Hg atmospheric backpressure (abs). Values for flow, power consumption and temperature rise: +/ 10% tolerance. -Data subject to change without notice.

5 1/2

4

3

60 Hz

10

0 100 200 300 400 500 cfm 0

20

40

60

80

100

In W

G

K06-TS

7 1/2

5 1/2

K05-TS

p

In

Hg

0

1

2

3

4

5

6

7

p

In

Hg

0

1

2

3

4

5

6

7

8

4

3

20

40

60

80

100

120

0 50 100 150 200 250 300 350 4000

cfm

50 Hz

In W

G

10

K06-TS

5 1/2

7 1/2

K05-TS

5 1/2

p

In

Hg

0

1

2

3

4

5

6

7

0

20

40

60

80

100

In W

G

0 20 40 60 80 100 °F

60 Hz

K05-TS

K06-TS

60 Hz

K06-TS

0

20

40

60

80

100

0 1 2 3 4 5 6 7 8 Hp

In W

G

9 10

K05-TS

p

In

Hg

0

1

2

3

4

5

6

7

0

20

40

60

80

120

0 1 2 3 4 5 6 7 8 Hp

In W

G

K05-TS

K06-TS

9 10

50 Hz

50 Hz

0

20

40

60

80

120

0 20 40 60 80 100 120 140 160 °F

In W

G

K06-TS K05-TS

p

In

Hg

0

1

2

3

4

5

6

7

8

p

In

Hg

0

1

2

3

4

5

6

7

8

45REGENERATIVE BLOWERS - VACUUM

Page 46: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Model Maximum

flow cfm

Installed power

Hp

Maximum differential pressure

∆p ( In Hg )

Noise level Lp dB (A)

(1)

Overall dimensions

H Weight

60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 3500 rpm 2900 rpm Inches Lbs

7 ½ 7 ½ 2.6 3.5 84.5 82.5 23.76 197.31 10 10 4.4 5.2 84.8 82.8 23.76 206.13 K07-TS 588 487 15 15 8.1 8.9 85.4 83.4 24.55 223.77

7 ½ 7 ½ 1.3 2.2 80.9 78.9 23.76 205.47 10 10 2.7 3.7 81.2 79.2 23.76 214.29 K08-TS 715 592 15 15 5.5 6.4 82.9 80.9 24.55 231.92

20 20 5.9 6.6 84.1 82.1 29.92 350.53 K09-TS 941 780 8.1 8.8 86.1 84.1 30.79 383.60

20 20 4.8 5.5 89.4 87.4 29.92 354.94 K10-TS 1093 906 25 25 5.9 7.0 89.7 87.7 30.79 388.01 25 25 3.7 5.0 90.7 88.7 31.38 429.02 K11-TS 1254 1039 30 (2) 30 (2) 5.1 6.6 91.3 89.3 31.38 434.53

K12-TS 1410 1168 30 (2) 30 (2) 3.3 5.9 91.9 89.9 31.50 436.75

Model a b c d e f G I j k m n o p1 q r s t u z

K07-TS 16.69 20.91 12.56 3.86 18.43 17.24 4”NPT 7.17 - - K08-TS 18.03 21.57 12.56 3.86 18.82 17.64 4”NPT 7.17 - - K09-TS 19.37 24.02 14.37 4.4 20.00 18.82 5.12 8.27 M16 8.27 0.51 9.84 21.65 33.46 - 12.40 0.20 M8 14.17 0.63K10-TS 20.31 24.53 14.37 4.41 20.00 18.82 5.12 8.27 M16 8.27 0.51 9.84 21.65 33.46 - 12.40 0.20 M8 14.17 0.63K11-TS 21.26 25.59 14.96 4.17 21.26 20.08 5.12 8.98 M16 8.27 0.51 9.84 21.65 34.25 - 12.60 0.20 M8 15.35 0.63

K12-TS 21.57 25.66 14.96 4.17 21.26 20.08 5.12 8.98 M16 8.27 0.51 9.84 21.65 34.37 - 12.60 0.20 M8 15.35 0.63

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744. (2) K11-K12-TS Hp 30 vertical assembly only.

SCL K07 / K08 / K09 / K10 / K11 / K12SERIES

- For proper use, the blower should be equipped with inlet filt- Ambient temperature from +5° to +104°F. - Specifications subject to change without notice.

Dimensions in inches. Dimension for reference only.

TECHNICAL CHARACTERISTICS - Aluminium alloy construction - Smooth operation - High efficiency impeller - Maintenance free - Mountable in any position - Recognized TEFC - cURus motor - G1/8” female thread on both suction

and discharge silencer port flanges

OPTIONS - Special voltages (IEC 38) - Surface treatments

ACCESSORIES - Inlet and/or inline filters - Additional inlet/outlet silencers - Safety valves - Flow converting device - Optional connectors

For model K09-K10-K11-K12 -TS only

j Int.k

øG

s G

e f I

d

c b

a

G 1/8”

For model K11-K12-TS Hp 30 60Hz only

Accessory

t

r o

n n øm

q

z H

p1

3x120°øu

TS SN 1826-12

46 REGENERATIVE BLOWERS - VACUUM

9.84 0.51

21.65 31.57 21.65 3 1.57 0.98

0.51 11.77 0.20 M8 11.61 0.63

11.77 0 .20 M8 12.20 0.63984

0.98

25 25

3500 rpm 2900 rp m 3500 rpm 2900 rpm 3500 rpm 2900 rpm

er and safety valve; other accessories available on request.

Page 47: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

CAPA

CITY

A

BSO

RBED

PO

WER

TE

MPE

RATU

RE IN

CRES

ASE

SERIES

Curves refer to air at 68° F temperature, measured at inlet port and 29.92 In Hg atmospheric backpressure (abs). Values for flow, power consumption and Data subject to change without notice.

0

1

2

3 4

5

6

7

8

9

10

p

In

Hg

K07-TS

K08-TS

K09-TS

K10-TS K11-TS

0

20

40

60

80

100

140

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 Hp

60 Hz

In W

G

K12-TS

0

1

2

3 4

5

6

7

8

9

10

p

In

Hg

0

20

40

60

80

100

140

0 20 40 60 80 100 120 °F

In W

G 60 Hz

K10-TS

K08-TS

K07-TS

K09-TS

K11-TS

K12-TS

0

1

2

3

4

5

6

7

8

9

10

p

In

Hg

In W

G

25

20

0

20

40

60

80

100

120

140

200 400 600 800 1000 1200 1400

K08-TS

10

15

15

10

7 1/2

K07-TS

7 1/2

K09-TS

20

25

K10-TS

K11-TS

25

30

30

K12-TS

1600 cfm

60 Hz

0

1

2

3

4

5

6

7

8

9

10

p

In

Hg

K10-TS

0

20

40

60

80

100

120

140

0 200 400 600 800 1000 1200 cfm

50 Hz

In W

G

K08-TS

K07-TS

K09-TS

K11-TS

25

20

10

15

15

10

7 1/2

7 1/2

20

25

25

30

30

0

1

2

3 4

5

6

7

8

9

10

p

In

Hg

K07-TS

K08-TS

K09-TS

K10-TS K11-TS

0

20

40

60

80

100

140

0 2 4 6 8 10 12 14 16 18 20 22 24 26 Hp

50 Hz

In W

G

K12-TS

0

1

2

3 4

5

6

7

8

9

10

p

In

Hg

0

20

40

60

80

100

140

0 20 40 60 80 100 120 140 160 180 200 °F

50 Hz

In W

G

K10-TS

K09-TS

K07-TS

K08-TS

K11-TS

K12-TS

K12-TS

TS SN 1826-12

47REGENERATIVE BLOWERS - VACUUM

temperature rise: +/-10% tolerance.

SCL K07 / K08 / K09 / K10 / K11 / K12

Page 48: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Model Maximum

flow cfm

Installed power

Hp

Maximum differential pressure

Dp ( In Hg )

Noise level Lp dB (A)

(1)

Overall dimensions

H Weight

60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm Inches Lbs

3 3 5.0 6.4 72.5 70.5 16.14 101.40 4 4 8.1 9.4 73.0 71.0 16.14 103.60

5 ½ 5 ½ 11.0 12.5 73.5 71.5 16.14 111.50 K07R-MD 129 107

7 ½ - 13.2 - 74.0 - 17.52 134.50 5 ½ 5 ½ 6.3 8.1 75.7 73.7 16.14 116.90 7 ½ 7 ½ 11.9 13.2 76.1 74.1 17.52 140.00 K08R-MD 168 139

10 - 13.2 - 76.4 - 17.52 151.00 5 ½ 5 ½ 4.0 5.7 76.4 74.4 16.54 144.40 7 ½ 7 ½ 8.8 10.5 77.5 75.5 17.95 167.60 K09-MD 221 183

10 10 14.0 14.0 79.0 77.0 17.95 178.60 7 ½ 7 ½ 6.3 8.1 80.4 78.4 17.91 170.90 10 10 10.3 12.1 80.7 78.7 17.91 181.90 K10-MD 275 228

15 15 14.7 14.7 81.3 79.3 19.29 203.90 10 10 7.4 9.2 80.7 78.7 18.11 211.60 15 15 14.0 14.7 81.3 79.3 19.49 232.60 K11-MD 306 254

20 - 14.7 - 81.6 - 23.23 287.20

15 15 7.4 13.2 82.2 80.2 19.61 240.30 K12-MD 336 278 20 - 13.2 - 82.5 - 23.42 295.00

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.

SN 1852-9 1/2

TECHNICAL CHARACTERISTICS - Aluminium alloy construction - Smooth operation - High efficiency impeller - Maintenance free - Mountable in any position - Recognized TEFC - cURus motor

OPTIONS - Special voltages (IEC 38) - Surface treatments

ACCESSORIES - Inlet and/or inline filters - Additional inlet/outlet silencers - Safety valves - Flow converting device - Optional connectors

Dimensions in inches. Dimension for reference only.

a

b

c

d

e f I

G s

n o

r q øm

H p1

3x120° øu

t

z

- For proper use, the blower should be equipped with inlet filter - Ambient temperature from +5° to +104°F. - Specifications subject to change without notice.

Model a b c d e f G I m n o p1 q r s t u z

K07R-MD 16.69 18.94 10.59 3.23 18.43 17.24 0.51 K08R-MD 17.99 19.61 10.K09-MD 19.37 22.09 12.40 3.78 20.00 18.82 4” NPT 7.17 0.51 11.81 13.78 25.35 0.98 0.20 M8 14.17K10-MD 20.31 22.56 12.40 3.78 20.00 18.82 4” NPT 7.17 0.51 11.81 13.78 25.35 0.98 10.12 0.20 M8 14.17 0.63 K11-MD 21.35 23.74 13.07 3.58 21.18 20.00 4” NPT 7.87 0.51 K12-MD 21.57 23.85 13.07 3.58 21.18 20.00 4” NPT 7.87 0.51 11.81 13.78 25.87 10.31 0.20 M8 15 .35 0.52

MD SERIES

SCL K07R / K08R / K09 / K10 / K11 / K12

48 REGENERATIVE BLOWERS - VACUUM

12.20 0.63 2” NPT 6.10

0 .20 M8 0.63

1.7 1 0.12

and safety valve; other accessories available on request.

11.81 13.78 16.46 0.71 1.7 0.20 M8 11.61 0.63 0.71 59 3.23 18.82 17.64 2” NPT 6.10 0.51 11.81 13.78 16.46

0.98

11.81 13.78 25.75 0.98 10.12 0.20 M8 14.17 0.63

Page 49: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

CAPA

CITY

A

BSO

RBED

PO

WER

TE

MPE

RATU

RE IN

CREA

SE

0 20 40 60 80 100 120 140 160 180 200 °F

SCL K07R / K08R / K09 / K10 / K11 / K12

SN 1852-9 2/2

Curves refer to air at 68° F temperature, measured at inlet port and 29.92 In Hg atmospheric backpressure (abs). Values for flow, power consumption and Data subject to change without notice.

cfm

p I

n Hg

0 1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

15

7 1/2

10

K10-MD

0

20

40

60

80

100

120

140

160

180

200

240

0 100 200 300 400

60 Hz

In W

G

K08R-MD

5 1/2

7 1/2

10

K07R-MD

3

4

7 1/2

K09-MD

10

7 1/2

20 15

10

K11-MD

5 1/2

5 1/2

15

20

K12-MD

cfm

240

p

In

Hg

0 1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

In W

G

K10-MD

0

20

40

60

80

100

120

140

160

180

200

0 100 200 300

50 Hz

K08R-MD

K07R-MD K09-MD K11-MD

15

7 1/2

10

5 1/2

7 1/2

3

4

10

7 1/2

15

10

5 1/2

5 1/2

K12-MD

15

0 2

4

6

8

10

12

14

16

p I

n Hg

0

20

40

60

80

100

120

140

160

180

240

0 2 4 6 8 10 12 14 20 Hp

In W

G

16 18

60 Hz

K07R-MD

K08R-MD

K09-MD K11-MD

K12-MD K10-MD

0 2

4

6

8

10

12

14

16

p I

n Hg

0 20 40 60

80

100

120

140 160 180

240

K10-MD

60 Hz

In W

G

K08R-MD

K07R-MD K09-MD

K12-MD

K11-MD

0 2

4

6

8

10

12

14

16

p I

n Hg

0

20

40

60

80

100

120

140 160 180

240

0 20 40 60 80 100 120 140 160 180 200

K10-MD

In W

G

°F

50 Hz

K08R-MD

K07R-MD

K09-MD

K11-MD

K12-MD

0 2

4

6

8

10

12

14

16

p I

n Hg

0

20

40

60

80

100

120

140

160

180

240

0 2 4 6 8 10 12 Hp

In W

G

14

50 Hz

K07R-MD

K08R-MD

K09-MD K11-MD

K12-MD K10-MD

MD SERIES

49REGENERATIVE BLOWERS - VACUUM

temperature rise: +/-10% tolerance.

Page 50: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Model Maximum

flow cfm

Installed power

Hp

Maximum differential pressure

p ( In Hg )

Noise le vel Lp dB (A)

(1)

Overall dimensions

H Weight

60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm Inches Lbs

K04-TD 99 82 2 2 5.1 7.0 70.6 68.6 17.26 62.83 3 3 8.8 8.1 71.6 69.6 17.26 69.44

K05-TD 153 127 3 3 5.1 7.0 72.6 70.6 17.45 84.88 4 4 7.7 9.9 74.1 72.1 18.64 88.18

5 ½ 5 ½ 11.0 11.8 75.6 73.6 18.64 92.59

K06-TD 222 184 5 ½ 5 ½ 5.9 8.8 74.6 72.6 18.98 103.62 7 ½ 7 ½ 9.2 10.3 75.6 73.6 22.60 139.99 10 10 11 .8 11.8 76.6 74.4 22.60 148.81

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request. - Ambient temperature from +5° to +104°F. - Specifications subject to change without notice.

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.

SCL K04 / K05 / K06

SERIES TD SN 193 1/2 6-6

a

d

b

c

s

e f

I2 G

t

3x120° øu

y I1 q

d1

w

45°

Model a b c d d1 e f G I1 I2 m n o p1 p2 q r r1 s t u w x y z

K04-TD 11.22 12.40 6.77 1.93 4.76 10.04 8.86 1” ½ NPT 4.84 2.01 0.47 3.74 6.73 12.44 10.00 0.71 2.76 0.59 0.16 M6 6.89 7.40 8.43 6.81 0.71

K05-TD 12.87 14.37 7.87 2.13 5.51 12.60 10.24 2” NPT 5.71 2.36 0.59 4.53 10.43 16.85 13.39 0.71 3.86 1.57 0.16 M8 7.87 11.26 11.54 8.11 0.75

K06-TD 14.80 16.54 9.13 2.32 6.69 12.80 11.42 2” NPT 5.94 2.87 0.59 5.51 10.43 19.92 13.94 0.71 5.35 0.75 0.16 M8 9.45 11.26 12.13 8.27 0.75

Dimensions in inches. Dimension for reference only.

G p1 H

z

q

o

p2 x

n r øm

r1

TECHNICAL CHARACTERISTICS - Aluminium alloy construction- Smooth operation - High efficiency impeller - Maintenance free - Mountable in any position - Recognized TEFC - cURus motor

OPTIONS - Special voltages (IEC 38) - Surface treatments

ACCESSORIES - Inlet and/or inline filters - Additional inlet/outlet silencers - Safety valves - Flow converting device - Optional connectors

50 REGENERATIVE BLOWERS - VACUUM

Page 51: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

CAPA

CITY

A

BSO

RBED

PO

WER

TE

MPE

RATU

RE

INCR

EASE

Curves refer to air at 68° F temperature, measured at inlet port and 29.92 In Hg atmospheric backpressure (abs). Values for flow, power consumpti -10% tolerance. on and temperature rise: +/Data subject to change without notice.

K04 / K05 / K06 SCL TD SERIES

SN 193 2/2 6-6

cfm

0

20

40

60

80

100

120

140

160

180

0 50 100 150 200

50 Hz

5 1/2 10

7 1/2

K06-TD K04-TD

2

3

4

3

K05-TD

5 1/2

p I

n Hg

0

1

2

3

4

5

6

7

8

9

10

11

12

13

3

4

5 1/2

0

20

40

60

80

100

120

140

160

180

0 50 100 150 200 250 cfm

60 Hz

In W

G

5 1/2

7 1/2

10

3

2

K04-TD K05-TD K06-TD

p I

n Hg

0 1

2 3

4

5

6

7

8 9

10

11

12

13

K06-TD

60 Hz

0

20

40

60

80

100

120

140

180

In W

G

0 1 2 3 4 5 6 7 8 Hp 9

K04-TD

K05-TD

p I

n Hg

0 1

2 3

4

5

6

7

8 9

10

11

12

13

0

20

40

60

80

100

120

140

180

In W

G

0 1 2 3 4 5 6 7 Hp

K06-TD

50 Hz

K05-TD

K04-TD

0

20

40

60

80

100

120

140

180

0 20 40 60 80 100 120 140 160 180

50 Hz

In W

G

°F

K05-TD

K06-TD

K04-TD

0

20

40

60

80

100

120

140

180

In W

G

0 20 40 60 80 100 120 140 160 180 °F

60 Hz

K05-TD

K04-TD

K06-TD

p

In H

g

0

1

2

3

4

5

6

7

8

9

10

11

12

13

p I

n Hg

0 1

2 3

4

5

6

7

8 9

10

11

12

13

p I

n Hg

0 1

2 3

4

5

6

7

8 9

10

11

12

13

51REGENERATIVE BLOWERS - VACUUM

Page 52: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Model Maximum

flow cfm

Installed power

Hp

Maximum differential pressure

∆∆∆∆p ( In Hg )

Noise level Lp dB (A)

(1)

Overall dimensions

H Weight

60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm Inches Lbs

K07-TD 296 245 7 ½ 7 ½ 6.6 7.7 78.6 76.6 23.76 194.0 10 10 9.9 11.0 78.9 76.9 23.76 202.815 15 13.2 12.6 79.5 77.5 24.55 220.5

K08-TD 368 305 7 ½ 7 ½ 4.3 5.5 79.0 77.0 23.76 202.210 10 7.0 8.1 79.3 77.3 23.76 211.015 15 12.5 13.6 79.9 77.9 24.55 228.6

K09-TD 467 387 15 15 7.7 9.2 82.2 80.2 25.81 222.720 20 11.7 13.2 82.5 80.5 29.92 347.2 25 - 14.0 - 82.8 - 30.79 380.3

K10-TD 571 473 15 15 6.3 7.4 85.9 83.9 25.81 271.2 20 20 9.6 11.0 86.2 84.2 29.92 351.6 25 25 13.2 14.7 86.5 84.5 30.79 384.7

K11-TD 642 532 20 20 6.6 8.5 86.7 84.7 31.38 392.6 25 25 9.6 11.4 87.2 85.2 31.38 425.7

K12-TD 716 593 25 25 6.3 10.3 87.5 85.5 31.50 423.5 30 30 8.8 14.0 88.0 86.0 31.50 429.0

(1) Noise measured at 1 m dis

SERIES

Model a b c d d1 e f G I1 I2 m n o p1 p2 q r s t u w x y z

K07-TD 16.69 18.94 10.59 3.23 7.56 18.43 17.24 3”NPT 7.36 3.05 0.51 11.81 13.78 25.55 15.43 0.98 5.39 0.20 M8 11.61 18.94 12.56 10.24 0.63

K08-TD 17.99 19.61 10.59 3.23 7.56 18.82 17.64 3”NPT 7.36 3.05 0.51 11.81 13.78 25.55 15.43 0.98 5.39 0.20 M8 12.20 18.94 12.56 10.24 0.63

K09-TD 19.37 22.09 12.4 3.78 8.86 20.0 18.82 4”NPT 8.66 3.58 0.51 11.81 13.78 29.33 17.91 0.98 7.83 0.20 M8 14.17 21.89 14.65 11.89 0.63

K10-TD 20.31 22.56 12.4 3.78 8.86 20.0 8.82 4”NPT 8.66 3.58 0.51 11.81 13.78 29.33 17.91 0.98 7.83 0.20 M8 14.17 21.89 14.65 11.89 0.63

K11 -TD 21.26 23.70 13.07 3.54 9.13 21.18 20.0 4”NPT 9.53 3.94 0.51 11.81 13.78 30.12 18.50 0.98 8.03 0.20 M8 15.35 21.89 15.24 12.76 0.63 K12-TD 21.57 23.81 13.07 3.54 9.13 21.18 20.0 4”NPT 9.53 3.94 0.51 11.81 13.78 30.23 18.50 0.98 8.03 0.20 M8 15.35 21.89 15.24 12.76 0.63

- For proper use, the blower should be equipped inlet filter and safety valve; other accessories a vailable on request. - Ambient temperature from +5° to +104°F. - Specifications subject to change without notice.

45°

q

d1

w

y

I1

d

b

e f

a

I2 G

c

s

3x120° øu

q

G

o

p1 H

p2 x

z

t

n r øm

Dimensions in inches. Dimension for reference only.

TECHNICAL CHARACTERISTICS - Aluminium alloy construction - Smooth operation - High efficiency impeller - Maintenance free - Mountable in any position - Recognized TEFC - cURus motor - G1/8” female thread on both suction

and discharge silencer port flanges

OPTIONS - Special voltages (IEC 38) - Surface treatments

ACCESSORIES - Inlet and/or inline filters - Additional inlet/outlet silencers - Safety valves - Flow converting device - Optional connectors

G 1/8”

G 1/8”

52 REGENERATIVE BLOWERS - VACUUM

tance with inlet and outlet ports piped, in accorda nce to ISO 3744.

SCL K07 / K08 / K09 / K10 / K11 /K12 TD SN 1834-11 1/2

with

Page 53: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

SERIES SN 1834-11 2/2

Curves refer to air at 68° F temperature, measured at inlet port and 29.92 In Hg atmospheric backpressure (abs). Values for flow, power consumption and temperature rise Data subject to change without notice.

CAPA

CITY

A

BSO

RBED

PO

WER

TE

MPE

RATU

RE IN

CREA

SE

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

p I

n Hg

0

2

4

6

8

10

12

14

16

p I

n Hg

0

2

4

6

8

10

12

14

16

p I

n Hg

K10 -TD

0

20

40

60

80

100

120

140

160

220

0 20 40 60 80 100 120 140 160 180 ° F

In W

G

K08-TD K07-TD

K09-TD

K11 -TD

In W

G

0

20

40

60

80

100

120

140

160

220

K10 -TD

0 5 10 14 20 25 Hp

K08-TD

K07-TD K09-TD K11 -TD

30

K12 -TD

25

K10-TD

20

7 1/2

0

20

40

60

80

100

120

140

160

180

220

0 100 200 300 400 500 600 700 cfm

In W

G

10

15

7 1/2

10

15

15

K08-TD

K07-TD K09-TD

15

20

25

25

20

K11-TD

800

30

25

K12-TD

60 Hz

K12 -TD

0

2

4

6

8

10

12

14

16

p

In H

g

0

2

4

6

8

10

12

14

16

p

In H

g

K10 -TD

0

20

40

60

80

100

120

140

160

180

240

0 20 40 60 80 100 120 140 160 180 200 °F

In W

G

K08-TD

K07-TD

K11 -TD

K09-TD

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

p

In H

g

K10 -TD

0

20

40

60

80

100

120

140

160

180

200

240

0 100 200 300 400 500 600

In W

G

cfm

K08-TD

K07-TD K09-TD K11 -TD

15

7 1/2

10

15

7 1/2

10

15

15

25

25

20

20

20

700

25

30

50 Hz

K12 -TD

0

20

40

60

80

100

120

140

160

180

240

In W

G

K10 -TD

0 5 10 15 20 Hp

K08-TD

K07-TD K09-TD K11 -TD

25 30

K12 -TD

K12 -TD

60 Hz

60 Hz

50 Hz

50 Hz

53REGENERATIVE BLOWERS - VACUUM

+/-10% tolerance.

SCL K07 / K08 / K09 / K10 / K11 / K12 TD

Page 54: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

- For proper use, the blower should be equipped with inlet filter - Ambient temperature from +5° to +104°F. - Specifications subject to change without notice.

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.

SCL 06

SN 2674-1 1/2

STANDARD FEATURES - Low weight cast aluminum construction. - Quiet operation with integral inlet and

outlet muffling. - Recognized TEFC - cURus motor. - High efficiency / low noise impeller

design. - No lubrication / maintenance required. - Allowed ambient: +5 °F to +104 °F. - Mountable in any plane. OPTIONS - Special voltages. - Surface treatment or plating. - Gas tight sealing. - Special designs available. ACCESSORIES - Inlet and/or inline filters. - Additional inlet/outlet silencers. - Safety valves. - Flow converting devices. - Optional connectors

Model Maximum

flow cfm

Installed power

Hp

Maximum differential pressure

p ( In Hg)

Noise level Lp dB (A)

(1)

Overall dimensions

H Weight

60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm Inches Lbs

1/3 - 2.7 - 58.7 - 10.60 18.30 06 39 32 1/2 1/2 3.5 2.4 59.0 58.0 10.60 18.50

Dimensions in inches. Dimension for reference only.

“P” version

1”NPT8.6

3.150.59 1.38

7.68.7

7.102.95

ø 0.43H

1.06

M5

5.35 DIA

4.644.56

4.373.38

4.13

M5

06 SERIES

54 REGENERATIVE BLOWERS - VACUUM

and safety valve; other accessories available on request.

Page 55: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Curves refer to air at 68° F temperature, measured at Values for flow, power consumption and Data subject to change without notice.

ABS

ORB

ED P

OW

ER

TEM

PERA

TURE

INCR

EASE

SCL 06

SN 2674- 2/2

CAPA

CITY

In W

G

0

10

20

40

Hp

50 Hz

0 0.05 0.1 0.15 0.2 0.30 25

30

0

1.0

2.0

0.5

1.5

2.5

p I

n Hg

40

0

10

20

In W

G

30

0 30 50 60 80 °F

50 Hz

2010 40 700

1.0

2.0

0 5

1.5

2.5

p I

n Hg

In W

G

60

0

10

20

30

40

0 0.1 Hp0.2 0.3 0.4 0.5

60 Hz

0

1 ,0

2,0

3,0

4,0

0,5

1 ,5

2,5

3,5 p I

n Hg

40

0 30 50 60 80 °F0

10

20

In W

G 60 Hz

20

30

10 40 70

60

90 1000

1 ,0

2,0

3,0

4,0

0,5

1 ,5

2,5

3,5 p I

n Hg

0

10

20

40

In W

G

30

0 10 20 30 40

50 Hz

1/2

cfm

p

In H

g

0

1

2

0.5

1.5

2.5

p I

n Hg

0

1.0

2.0

3.0

4 0

0.5

1.5

2.5

3.5

cfm0

10

20

30

40

50

60

In W

G

0 10 20 30 40

60 Hz

1/3

1/2

06 SERIES

.

.

.

55REGENERATIVE BLOWERS - VACUUM

temperature rise: +/-10% tolerance. inlet port and 29.92 In Hg atmospheric backpressure (abs).

1

Page 56: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

SCL 10DL / 15DH

SN 2198-3 1/2

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories available on request. - Ambient temperature from +5° to +104°F. - Specifications subject to change without notice.

Model Maximum

flow cfm

Installed power

Hp

Maximum differential pressure

∆p ( In Hg)

Noise level Lp dB (A)

(1)

Overall dimensions

H Weight

60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm

Inches Lbs

1/3 1/3 4.4 4.4 63.7 61.7 12.20 21.80 10DL 21 18

1/2 1/2 6.3 4.9 64.0 62.0 12.76 23.50 3/4 3/4 7.2 7.7 63.7 61.7 14.25 32.50 15DH 35 29 1 1 8.1 8.1 64.0 62.0 15.75 40.00

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.

Model a b c d e f G I m n o r s

10DL 8.66 10.08 9.06 0.91 8.27 7.09 1/2" NPT 2.28 0.35 4.72 5.67 3.54 0.10

15DH 9.84 11.26 0.10

STANDARD FEATURES - Low weight cast aluminum construction. - Quiet operation with integral inlet and outlet

muffling. - Recognized TEFC - cURus motor. - High efficiency / low noise impeller design. - No lubrication / maintenance required. - Allowed ambient: +5 °F to +104 °F. - Mountable in any plane.

OPTIONS - Remote drive models (belt or coupling). - Special voltages. - Surface treatment or plating. - Gas tight sealing. - Special designs available.

ACCESSORIES - Inlet and/or inline filters. - Additional inlet/outlet silencers. - Safety valves. - Flow converting devices. - Optionals connectors

d

G

rnoH

l

a

øm fe

b

c

s

Dimensions in inches. Dimension for reference only.

DH SERIES

56 REGENERATIVE BLOWERS - VACUUM

10.16 1.18 8.27 7.09 3/4" NPT 2.52 0.35 4.72 5.67 4.72

Page 57: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Curves refer to air at 68° F temperature, measured at inlet port and 29.92 In Hg atmospheric backpressure (abs). Values for flow, power consumption and temperature rise: +/-10% tolerance. Data subject to change without notice.

ABS

ORB

ED P

OW

ER

TEM

PERA

TURE

INCR

EASE

CA

PACI

TY

80

120

60

40

20

0 1 Hp 0,8 0,6 0,4 0,2 0

In W

G

50 Hz

10DL

15DH

p I

n Hg

0 1

2

3

4

5

6

7

8

0

1

2

3

4

5

6

7

8 p I

n Hg

0

1

2

3

4

5

6

7

8

0

1

2

3

4

5

6

7

8

p I

n Hg

°F

p I

n H

g

0 1

2

3

4

5

6

7

8

12060 80 10040 20 0

In W

G

60

80

120

40

20

0

50 Hz

10DL

15DH

p I

n H

g

0 1

2

3

4

5

6

7

8

120

In W

G

80

60

40

20

0 0 0,2 0,4 0,6 1 Hp0,8

10DL

15DH

60 Hz

p I

n Hg

0 1

2

3

4

5

6

7

8

cfm 40 30 20 10 0

40

20

0

80

120

In W

G

100

1

1/2

50 Hz

3/4

10DL

15DH

80

60

40

20

0°F

120

In W

G

100 12080 60 40 20 0

15DH

10DL

60 Hz

60 1/3

cfm 0

20

40

60

80

100

120

0 20 4010 30

In W

G 1

1/3

60 Hz

10DL

15DH

1/2

3/4

57REGENERATIVE BLOWERS - VACUUM

SCL 10DL / 15DH

SN 2198-3 /2 DH SERIES

2

Page 58: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

- For proper use, the blower should be equipped with inlet filter - Ambient temperature from +5° to +104°F. - Specifications subject to change without notice.

Model Maximum

flow cfm

Installed power

Hp

Maximum differential pressure p ( In Hg )

Noise level Lp dB (A)

(1)

Overall dimensions

H Weight

60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm Inches Lbs

1 ½ 1 ½ 8.8 68.0 65.0 13.86 47.30 30DH 70 61 2 2 10.3 8.9 69.7 67.7 15.36 58.30 40DH 98 85 3 3 11.1 10.3 74.7 71.7 16.93 75.00

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.

SCL R20-MD / 30DH / 40DH

SN 2465-2 1/2

STANDARD FEATURES - Low weight cast aluminum construction. - Quiet operation with integral inlet and outlet

muffling. - Recognized TEFC - cURus motor. - High efficiency / low noise impeller design. - No lubrication / maintenance required. - Allowed ambient: +5 °F to +104 °F. - Mountable in any plane. OPTIONS - Remote drive models (belt or coupling). - Special voltages. - Surface treatment or plating. - Gas tight sealing. - Special designs available. ACCESSORIES - Inlet and/or inline filters. - Additional inlet/outlet silencers. - Safety valves. - Flow converting devices. - Optional connectors

r

øm

p1

o

nq

H

3x120°øu

t

z

sl

G

d

c

a

fe

b

DH SERIES

58 REGENERATIVE BLOWERS - VACUUM

and safety valve; other accessories available on request.

Dimensions in inches. Dimension for reference only.

Model a b c d e f G I m n o p1 q r s t u z

11.22 12.20 6.57 1.77 9.05 8.27 1” ¼ NPT 30DH 12.60 13.66 7.36 2.09 10.63 9.64 1” ½ NPT 4.13 0.39 7.28 9.25 6.54 0.71 2.17 0.79 M6 7.09 0.67 40DH 13.78 14.57 7.68 2.09 10.63 9.65 1” ½ NP 4.13 0.39 7.28 9.25 7.32 0.71 2.17 0.79 M8 8.86 - T 1

1

0. 78 M6 5.91 -3.54 0.40 5.90 7.68 .5 0.71 1.77 130R2 -MD

34 41 8.8R20-MD

Page 59: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Curves refer to air at 68° F temperature, measured at inlet port and 29.92 In Hg atmospheric backpressure (abs). Values for flow, power consumption and Data subject to change without notice.

ABS

ORB

ED P

OW

ER

TEM

PERA

TURE

INCR

EAS

E

SCL 20DH / 30DH / 40DH

SN 2465- 2/2

CAPA

CITY

p I

n Hg

0 1

2

3

4

5

6

7

8

9

10

11

100

160

120

80

60

40

20

0 100 140120 80 60 40 20 0

In W

G 60 Hz

30DH

°F

40DH

p I

n Hg

0

1

2

3

4

5

6

7

8

9

10

11

cfm

50 Hz

100 80 60 40 20 0

60

40

20

0

80

100

120

140

160

21 1/2

30DH

In W

G

1

3

40DH

p I

n Hg

0

1

2

3

4

5

6

7

8

9

10

11

2 5 Hp 2 1.5 1 0.5 0

60

80

100

120

160

40

20

0

In W

G

30DH

50 Hz

40DH

p I

n Hg

0

1

2

3

4

5

6

7

8

9

10

11

12060 80 10040200

In W

G

°F

60

80

100

120

160

40

20

0

50 Hz

30DH

40DH

p I

n Hg

0 1

2

3

4

5

6

7

8

9

10

11

In W

G

160

120 100 80 60 40 20

0 0 0.5 1 1.5 2 2.5 3 3 5 Hp

30DH

60 Hz

40DH

p I

n Hg

0

1

2

3

4

5

6

7

8

9

10

11

cfm 100 80 0 20 40 60 1200

20

40

60

80

100

120

140

160

2

30DH

60 Hz

In W

G

3

40DH

DH SERIES

..

59REGENERATIVE BLOWERS - VACUUM

temperature rise: +/-10% tolerance.

1 1/2

R20-MDR20-MD

R20-MD R20-MD

R20-MDR20-MD

2

Page 60: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

TECHNICAL CHARACTERISTICS - Aluminium alloy construction - Smooth operation - High efficiency impeller - Maintenance free - Mountable in any position OPTIONS - Special voltages (IEC 38) - Surface treatments ACCESSORIES - Inlet and/or inline filters - Additional inlet/outlet silencers - Safety valves - Flow converting device - Optional connectors

Model Maximum

flow cfm

Installed power

Hp Size

Maximum differential pressure

Noise level Lp dB (A)

(1) Weight

(2) 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz Lbs 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm GOR GVR

K03-MS 52 43 3/4 NEMA 56C 4.7 3.7 61.0 59.0 22.00 17.601 ½ NEMA 56C 4.3 63.8

2 NEMA 56C 6.3 64.0 K04-MS 98 81

3 NEMA 56C 6.6

5.9

64.2

61.8 27.60 22.00

2 NEMA 143-5TC 3.8 5.2 69.5 67.5 NEMA 143-5TC

35.00 28.003

NEMA 182-4TC 69.8 K05-MS 156 129

5 NEMA 182-4TC 8.1 7.1

70.4 67.8

34.50 27.00

NEMA 143-5TC 46.00 38.403

NEMA 182-4TC 3.7 4.8 72.0 70.0

5 NEMA 182-4TC 6.3 72.6 K06-MS 216 179

7 ½ NEMA 182-4TC 9.6 8.1

72.9 70.6

40.80 38.00

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744. (2) Value is refered to weight of the machine without electric motor.

SCL K03 / K04 / K05 / K06MS SERIES - GOR/GVR RANGE

SN 2582-1 1/2

- For proper use, the blower should be equipped with inlet filter - Ambient temperature from +5° to +104°F. - Specifications subject to change without notice.

For dimensions, please refer to drw: -- GG OO RR range: SS II 11 885522 -- GG VVRR range: SS II 11 994466

GOR Range GVR Range

SCL Kxx-MS GOR-A SCL Kxx-MS GOR-C

60 REGENERATIVE BLOWERS - VACUUM

and safety valve; other accessories available on request.

∆p ( in Hg )

6.6

Page 61: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

CAPA

CITY

A

BSO

RBED

PO

WER

TE

MPE

RATU

RE IN

CREA

SE

SCL K03 / K04 / K05 / K06MS SERIES - GOR/GVR RANGE

SN 2582- 2/2

Curves refer to air at 68° F temperature, measured at inlet port and 29.92 In Hg atmospheric backpressure (abs). Values for flow, power consumption and Data subject to change without notice.

p

In H

g

0

1

2

3

4

5

6

7

8

9

10

2

3

5

0

20

40

60

80

100

120

140

0 50 100 150 200 250

In W

G 60 Hz

cfm

7 1/2

5

3

1 1/2

3

3/4

K05-MS K06-MS K04-MS K03-MS

2

p

In H

g

0

1

2

3

4

5

6

7

8

9

10

0 20 40 60 80 100 120 140 160 180 200 °F

0

20

40

60

80

100

140

In W

G 60 Hz

K06-MS

K04-MS

K03-MS

K05-MS

p

In H

g

0

1

2

3

4

5

6

7

8

2

3

0

20

40

60

80

100

120

0 50 100 150 200 cfm

In W

G 50 Hz

5

3

1 1/2

3/4

K05-MS K06-MSK04-MSK03-MS

p

In H

g

0

1

2

3

4

5

6

7

8

0

20

40

60

80

120

In W

G

0 1 2 3 4 5 Hp

50 Hz

K05-MS

K06-MS

K04-MS

K03-MS

p

In H

g

0

1

2

3

4

5

6

7

8

0

20

40

60

80

120

0 20 40 60 80 100 120 140 160 180 200 °F

50 Hz

In W

G

K04-MS

K03-MS

K06-MS

K05-MS

0

1

2

3

4

5

6

7

8

9

10

p

In H

g

0

20

40

60

80

100

140

0 1 2 3 4 5 6 7

In W

G

60 Hz

K05-MS

K06-MS

K04-MS

K03-MS

Hp

61REGENERATIVE BLOWERS - VACUUM

temperature rise: +/-10% tolerance.

1

Page 62: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Model Maximum

flow cfm

Installed power

Hp Size

Maximum differential pressure

Noise level Lp dB (A)

(1)

Weight (2)

60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm Lbs

5 NEMA 182-4TC 5.1 6.3 78.0 76.0 110.50

NEMA 182-4TC 110.50 K07-MS 294 243 7 ½

NEMA 213-5TC 9.6 8.8 78.3 76.3

110.50

5 NEMA 182-4TC 2.8 3.8 78.8 76.8 127.00

NEMA 182-4TC 127.00 7 ½

NEMA 213-5TC 5.0 6.6 79.1 77.1

127.00

10 NEMA 213-5TC 8.5 127.00

NEMA 213-5TC 127.00

K08-MS 381 316

15 NEMA 254-6TC

10.3 9.2

79.7 77.4

130.60

NEMA 182-4TC 133.40 7 ½

NEMA 213-5TC 3.7 4.6 79.3 77.3

133.40

10 NEMA 213-5TC 5.9 7.0 79.6 77.6 133.40

NEMA 213-5TC 133.40

K09-MS 471 390

15 NEMA 254-6TC

10.3 9.6 80.4

78.1 137.00

NEMA 182-4TC 147.30 7 ½

NEMA 213-5TC 2.2 3.7 79.4 77.4

147.30

10 NEMA 213-5TC 4.4 5.9 79.7 77.7 147.30

NEMA 213-5TC 147.30 15

NEMA 254-6TC 8.1 80.2

151.00

K10-MS 556 460

20 NEMA 254-6TC 10.3 9.6

80.5 78.2

151.00

10 NEMA 213-5TC 2.9 3.9 82.0 80.0 170.00

NEMA 213-5TC 170.00 15

NEMA 254-6TC 5.9 7.1 82.5 80.5

176.40

20 NEMA 254-6TC 9.2 83.0 176.40

K11-MS 650 539

25 NEMA 284-6TSC 10.3 9.6

83.8 81.0

170.00

NEMA 213-5TC 177.70 15

NEMA 254-6TC 3.8 6.6 83.5 81.5

184.10

20 NEMA 254-6TSC 6.3 84.3 184.10

25 NEMA 284-6TSC 8.8 87.2 177.70

K12-MS 726 602

30 NEMA 284-6TSC 10.3 9.6

87.6 82.3

177.70

SCL K07 / K08 / K09 / K10 / K11 / K12MS SERIES - GOR/GVR RANGE

SN 21 35-3 1 /2

- For proper use, the blower should be equipped with inlet filte nd safety valve; other accessories available on request. - Ambient temperature rom +5° to +104°F. - Specifications subject to change without notice.

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744. (2) Value is refered to weight of the machine without electric motor

GVR RangeGOR Range

SCL Kxx-MS GOR-C

SCL Kxx-MS GOR-A SCL Kxx-MS GOR-B

For dimensions, please refer to drw: GG OO RR range: SS II 11 887733 GG VVRR range: SS II 11 992200

TECHNICAL CHARACTERISTICS - Aluminium alloy construction - Smooth operation - High efficiency impeller - Maintenance free - Mountable in any position

OPTIONS - Special voltages (IEC 38) - Surface treatments

ACCESSORIES - Inlet and/or inline filters - Additional inlet/outlet silencers - Safety valves - Flow converting device - Optional connectors

62 REGENERATIVE BLOWERS - VACUUM

r a

80.1

79.4

∆p ( in Hg )

f

Page 63: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Curves refer to air at 68° F temperature, measured inlet port and 29.92 In Hg atmospheric backpressure (abs). Values for flow, power consumption and Data subject to change without notice.

CAPA

CITY

A

BSO

RBED

PO

WER

TE

MPE

RATU

RE IN

CREA

SE

SCL K07 / K08 / K09 / K10 / K11 / K12MS SERIES - GOR/GVR RANGE

SN 2135- 2/2

0 1 2

3

4

5

6

7

8

9

10

11

p I

n Hg

K11-MS

K09-MS

K08-MS K07-MS

K10-MS

60 Hz

Hp 0 5 10 15 20 250

20 40 60 80

100 120

160

In W

G

K12-MS

0 1 2

3

4

5

6

7

8

9

10

11

p I

n Hg

0 20 40 60 80 100 120 140 160 °F

0 20

40

60

80

100

120

160

In W

G

180

60 Hz

K10-MS K08-MS

K11-MS

K09-MS

K07-MS

K12-MS

0

1

2

3

4

5

6

7

8

9

10

p I

n Hg

50 Hz

K07-MS K11-MS

K10-MS

K09-MS

0

20

40

60

80

100

140

In W

G

Hp0 8 182 4 6 10 12 14 16

K08-MS K12-MS

0

1

2

3

4

5

6

7

8

9

10

p I

n Hg

50 Hz

0 20 40 60 100 120 140 160 °F

0

20

40

60

80

100

In W

G

80

K08-MS

K09-MS

K11-MS

K07-MS

K10-MS

K12-MS

140

0

1

2

3

4

5

6

7

8

9

10

11

p I

n Hg

200 300 400 500 8000 100 600 700 0

20

40

60

80

100

120

140

In W

G

160

K11-MS

K08-MS

7 1/2

10

15

10

15 20 25

15

20

15

10

5

7 1/2

10

7 1/2

K07-MS K09-MS

K10-MS

5

7 1/2

30

25

15

K12-MS

60 Hz

20

0

1

2

3

4

5

6

7

8

9

10

p I

n Hg

0 100 200 300 400 500 700 cfm 0

20

40

60

80

100

120

140

In W

G

600

K07-MS

K10-MS K08-MS

K11-MSK09-MS

K12-MS

10

15

5

7 1/2

10

7 1/2

7 1/2 10

15

2015

10

5

7 1/2

20

15

50 Hz

63REGENERATIVE BLOWERS - VACUUM

temperature rise: +/-10% tolerance.

3

cfm

at

Page 64: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

- For proper use, the blower should be equipped with inlet filter - Ambient temperature from +5° to +104°F. - Specifications subject to change without notice.

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744. (2) Value is refered to weight of the machine without electric motor.

SCL K05 / K06TS SERIES - GOR/GVR USA RANGE

SN 2688-1 1/2

For dimensions, please refer to drw: -- GG OO RR range: SS II 2211 2233 -- GG VVRR range: SS II 2211 3355

Model Maximum

flow m³/h

Installed power

Hp Size

Maximum differential pressure

∆p ( in Hg )

Noise level Lp dB (A)

(1)

Weight (2)

60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz Lbs 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm GOR GVR

5.0 4.4 6.3 75.1 73.1 K05-TS 290 241 7.5

NEMA 182-4TC7.4 6.7 77.1 75.1

72.75 68.35

7.5 4.1 5.7 77.1 75.1 10 5.9 77.4 75.4 K06-TS 400 331

15

NEMA 213-5TC

7.8 7.4

78.0 76.0

112.45 108.00

TECHNICAL CHARACTERISTICS - Aluminium alloy construction - Smooth operation - High efficiency impeller - Maintenance free - Mountable in any plane - G1/8'' female thread on both suction and discharge silencer port flanges. OPTIONS - Special voltages (IEC 38) - Surface treatments

SCL Kxx-TS GOR-C

G 1/8”

GVR RangeGOR Range

G 1/8”

SCL Kxx-TS GOR-A SCL Kxx-TS GOR-B SCL Kxx-TS GOR-C

64 REGENERATIVE BLOWERS - VACUUM

and safety valve; other accessories available on request.

Page 65: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

SCL K05 / K06TS SERIES - GOR/GVR RANGE

SN 2688- 2/2

CAPA

CITY

A

BSO

RBED

PO

WER

TE

MPE

RATU

RE IN

CREA

SE

60 Hz

In W

G

0

20

40

60

80

120

0 100 200 300 400 500 Scfm

7 1/2

5

10

60 Hz

0

20

40

60

80

120

0 1 2 3 4 5 6 7 8 Hp

In W

G

9 12

K05-TS

K06-TS

K05-TS

K06-TS

0 20 40 60 80 °F 0

20

40

60

120

In W

G

60 Hz

0 1 2 3 4 5 6 7 8 Hp9 100

20

40

60

80

120

In W

G

K05-TS

K06-TS

50 Hz

K06-TS

50 Hz

0 20 40 80 140 °F 60 100 120

K05-TS

0

20

40

60

80

120

In W

G

20

40

60

80

100

120

0 50 100 150 200 250 300 350 4000

Scfm

In W

G

K05-TS

K06-TS

5

7 1/2

7 1/2

10100

15

7 1/2

10 11

80

100 120 140

50 Hz

K05-TS

K06-TS

p

In

Hg

0

1

2

3

4

5

6

7

8

p

In

Hg

0

1

2

3

4

5

6

7

8

p

In

Hg

0

1

2

3

4

5

6

7

8

p

In

Hg

0

1

2

3

4

5

6

7

8

p

In

Hg

0

1

2

3

4

5

6

7

8

p

In

Hg

0

1

2

3

4

5

6

7

8

Curves refer to air at 20°C temperature, measured at inlet port and 1013 mbar (abs) atmospheric backpressure. Values for flow, power consumption and Data subject to change without notice.

65REGENERATIVE BLOWERS - VACUUM

temperature rise: +/-10% tolerance.

1

Page 66: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

SCL K07 / K08 / K09 / K10 / K11 / K12 TS SERIES - GOR/GVR RANGE

SN 2165-4 1/2

For dimensions, please refer to drw: GG OO RR range: SS II 11 887799 GG VVRR range: SS II 11 888800

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories a vailable on request.

- Ambient temperature from +5° to +104° F. - Specifications subject to change without notice.

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744. (2) Value is refered to weight of the machine without electric motor (3) Not applicable on SCL Kxx - GVR

SCL Kxx-TS GOR-A

SCL Kxx-TS GOR-B

GVR RANGE

TECHNICAL CHARACTERISTICS - Aluminium alloy construction - Smooth operation - High efficiency impeller - Maintenance free - Mountable in any position - G1/8” female thread on both

suction and discharge silencer port flanges

OPTIONS - Special voltages (IEC 38) - Surface treatments

ACCESSORIES - Inlet and/or inline filters - Additional inlet/outlet silencers - Safety valves - Flow converting device - Optional connectors

SCL Kxx-TS GOR-C

GOR RANGE

G 1/8”

G 1/8”

Model Maximum

flow cfm

Installed

power

Hp

Size Maximum

differential pressure ∆∆∆∆p ( In Hg )

Noise level Lp dB (A)

(1)

Weight (2)

60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2

NEMA 182-4TC 2.6 4.4 84.5 82.5 160.90 7 ½

NEMA 213-5TC 2.6 4.4 84.5 82.5 160.90

10 NEMA 213-5TC 4.4 6.6 84.8 82.8 160.90

NEMA 213-5TC 8.1 8.1 85.4 83.4 160.90 15

NEMA 254-6TC (3) 8.1 8.1 85.4 83.4 167.60

K07-TS 588 487

20 NEMA 254-6TC (3) 8.8 8.1 85.9 83.4 167.60

10 NEMA 213-5TC 2.7 4.7 81.2 79.2 172.00

NEMA 213-5TC 5.5 7.7 82.9 80.9 172.00 15

NEMA 254-6TC (3) 5.5 7.7 82.9 80.9 180.80 20 NEMA 254-6TC (3) 7.4 8.8 84.8 80.8 180.80

K08-TS 715 592

25 NEMA 284-6TSC (3) 9.6 8.8 87.0 80.8 174.20

NEMA 213-5TC 3.8 5.5 82.2 80.2 202.80 15

NEMA 254-6TC (3) 3.8 5.5 82.2 80.2 208.30

20 NEMA 254-6TC (3) 5.9 7.9 84.1 82.1 208.30 25 NEMA 284-6TSC (3) 8.1 8.8 86.1 84.1 205.00

30 NEMA 284-6TSC (3) 8.8 8.8 88.1 84.1 205.00

K09-TS 941 780

40 NEMA 324-6TSC (3) 9.6 8.8 90.1 84.1 220.50

NEMA 213-5TC 3.0 4.7 89.1 87.1 209.40 15

NEMA 254-6TC (3) 3.0 4.7 89.1 87.1 216.10 20 NEMA 254-6TC (3) 4.8 6.6 89.4 87.4 216.10

25 NEMA 284-6TSC (3) 5.9 8.1 89.7 87.7 211.60

30 NEMA 284-6TSC (3) 7.4 9.6 90.0 88.0 211.60

K10-TS 1093 906

40 NEMA 324-6TSC (3) 10.3 9.6 90.3 88.0 227.10

25 NEMA 284-6TSC 3.7 6.5 90.7 88.7 251.30

30 NEMA 284-6TSC 5.1 8.1 91.3 89.3 251.30

40 NEMA 324-6TSC (3) 7.4 9.6 91.9 89.9 269.00 K11-TS 1254 1039

50 NEMA 324-6TSC (3) 10.3 9.6 92.5 89.9 269.00

30 NEMA 284-6TSC 3.3 5.9 91.9 89.9 249.10

40 NEMA 324-6TSC (3) 5.2 8.8 92.5 90.5 266.80 K12-TS 1410 1168

50 NEMA 324-6TSC (3) 8.1 - 93.1 - 266.80

66 REGENERATIVE BLOWERS - VACUUM

900 rpm Lbs

Page 67: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Curves refer to air at 68° F temperature, measured at inlet port and 29.92 In Hg atmospheric backpressure (abs). Values for flow, power consumption and temperature rise: +/-10% tolerance. Data subject to change without notice.

CAPA

CITY

A

BSO

RBED

PO

WER

TE

MPE

RATU

RE IN

CREA

SE

SCL K07 / K08 / K09 / K10 / K11 / K12 TS SERIES - GOR/GVR RANGE

SN 2165- 2/2

0

1

2

3

4

5

6

7

8

9

10

11

p I

n Hg

K10 -TS

K09-TS

K08TS K11 -TS

K07-TS

0 20 40 60 80 100 120 140 160 °F

0

20

40

60

80

100

120

160

In W

G 60 Hz

K12 -TS

0

1

2

3

4

5

6

7

8

9

10

p I

n Hg

0 20 40 60 80 100 120 140 160 °F 180

0

20

40

60

80

100

140

In W

G

K08-TS

K10 -TS

K09-TS K11 -TS

K12 -TS

K07-TS

50 Hz

0

1

2

3

4

5

6

7

8

9

10

p I

n Hg

0

20

40

60

80

100

140

In W

G

0 10 5 15 20 25 30

K07-TS K11 -TS

K10 -TS K08-TS

K09-TS

35 Hp 40

K12 -TS

50 Hz

0

1

2

3

4

5

6

7

8

9

10

p I

n Hg

0

20

40

60

80

100

120

140

In W

G

0 200 400 600 800 1000 1200 cfm

K07-TS

K10 -TS K08-TS

K11 -TS K09-TS

15

15

25

30

40 30

25

20

7 1/2

10

15

20

15

10

20

25

K12 -TS

40

30

50 Hz

K11 -TS K09-TS

K08-TS

K07-TS

K10 -TS

Hp 0 10 20 30 40 50

0

20

40

60

80

100

120

160

In W

G

0

1

2

3

4

5

6

7

8

9

10

11

p I

n Hg

K12 -TS

60 Hz

1

2

3

4

5

6

7

8

9

10

11

p I

n Hg

0

20

40

60

80

100

120

140

In W

G

160

200 400 600 800 1000 1200 1400

10

7 1/2

15 20

25

20

15

10

15

20

25 30

40 40 50

30 40

25

20

15 25

30

K07-TS

K08-TS K10-TS

K11-TS K09-TS

50

40

30

1600 cfm

K12-TS

60 Hz

67REGENERATIVE BLOWERS - VACUUM

4

Page 68: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Model Maximum

flow cfm

Installed power

Hp Size

Maximum differential pressure

∆p ( In Hg )

Noise level Lp dB (A)

(1)

Weight (2)

60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm Lbs

NEMA 56C 112.00 3

NEMA 143-5TC 5.0 6.4 72.5 70.5

112.00 5 NEMA 182-4TC 10.7 12.5 73.5 71.5 113.80

NEMA 182-4TC 113.80 K07R-MD 129 107

7 ½ NEMA 213-5TC

13.2 13.2 74.0 72.0 113.80

5 NEMA 182-4TC 5.9 8.1 75.7 73.7 130.30 NEMA 182-4TC 130.30

7 ½ NEMA 213-5TC

11.9 13.2 76.1 74.1 130.30

K08R-MD 168 139

10 NEMA 213-5TC - 76.5 - 130.30

5 NEMA 182-4TC 3.7 5.7 76.4 74.4 138.50 NEMA 182-4TC 138.50

7 ½ NEMA 213-5TC

8.8 10.5 77.5 75.5 138.50

K09-MD 221 183

10 NEMA 213-5TC 13.6 13.2 79.0 77.0 138.50

NEMA 182-4TC 125.40 7 ½

NEMA 213-5TC 6.3 8.1 80.4 78.4

152.40 10 NEMA 213-5TC 10.3 12.1 80.7 78.7 152.40

K10-MD 275 228

15 NEMA 213-5TC 14.7 14.0 81.3 79.3 152.40

10 NEMA 213-5TC 7.4 9.2 80.7 78.7 175.70 NEMA 213-5TC 175.70 K11-MD 306 254

15 NEMA 254-6TC

14.0 14.0 81.3 79.3 182.10

NEMA 213-5TC 183.40 15

NEMA 254-6TC 7.4 13.2 82.2 80.2

189.80 K12-MD 336 278 20 NEMA 254-6TC 13.2 - 82.5 - 189.80

SCL K07R / K08R / K09 / K10 / K11 / K12MD SERIES - GOR/GVR RANGE

SN 2150-2 1/2

TECHNICAL CHARACTERISTICS - Aluminium alloy construction - Smooth operation - High efficiency impeller - Maintenance free - Mountable in any position

OPTIONS - Special voltages (IEC 38) - Surface treatments

ACCESSORIES - Inlet and/or inline filters - Additional inlet/outlet silencers - Safety valves - Flow converting device - Optional connectors

For dimensions, please refer to drw: GG OO RR range: SS II 11 9911 88 GG VVRR range: SS II 11 9911 99

- For proper use, the blower should be equipped with inlet filter - Ambient temperature from +5° to +104°F. - Specifications subject to change without notice.

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744. (2) Value is refered to weight of the machine without electric motor

GVR Range GOR Range

SCL Kxx-MD GOR-C

SCL Kxx-MD GOR-A

SCL Kxx-MD GOR-B

68 REGENERATIVE BLOWERS - VACUUM

and safety valve; other accessories available on request.

13.2

Page 69: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Curves refer to air at 68° F temperature, measured at Values for flow, power consumption and Data subject to change without notice.

CAPA

CITY

A

BSO

RBED

PO

WER

TE

MPE

RATU

RE IN

CREA

SE

SCL K07R / K08R / K09 / K10 / K11 / K12MD SERIES - GOR/GVR RANGE

SN 2150- 2/2

Hp 0 2 10 12 18 200

20 40 60 80

100 120 140

In W

G

4 6 8

160

220

∆p

In H

g

0 1 2 3 4 5 6 7 8 9

10 11 12 13 14 15 16

14 16

60 Hz

K07R-MD

K11-MD K10-MD

K08R-MD

K09-MD K12-MD

K08R-MD

K09-MD

K07R-MD

K10-MD

K11-MD 50 Hz

0 20 40 60 100 120 140 160 °F 80 180

0

20

40

60

80

100

120

In W

G

140

200

∆p

In H

g

0 1 2 3 4 5 6 7 8 9

10 11 12 13 14

K12-MD

0 20 40 60 80

100 120

In W

G

140

200

Hp0 8 2 4 6 10 12

∆p

In H

g

0 12 3 4 567 8 9

1011 12 13 14

14

K07R-MD

K11-MD K10-MD

K08R-MD

K09-MD K12-MD

50 Hz

∆p

In H

g

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

0 100 200 300 cfm 0

20

40

60

80

100

120

140

In W

G

160

200

K07R-MD

K10-MD K08R-MD

K11-MD K09-MD

3

7 1/2

10

7 1/2

15

5 7 1/2

10

5

5

7 1/2 10

15

K12-MD

15

50 Hz

°F

0 20

40

60

80

100

120

220

In W

G

140

160

0 20 40 60 80 100 120 140 160 180 200

K10-MD

K08R-MD K07R-MD

K11-MD

K09-MD

∆p

In H

g

0 1 2 3 4 5 6 7 8 9

10 11 12 13 14 15 16

K12-MD

60 Hz

cfm

∆p

In H

g

0 1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

0

20

40

60

80

100

120

140

In W

G

160

180

220

200 300 4000 100

K10-MD

K11-MDK09-MD

60 Hz

15 7 1/2

15 10

5

3 5

5

7 1/2

10

10

7 1/2

7 1/2

K12-MD

15

20

K07R-MD

K08R-MD

10

69REGENERATIVE BLOWERS - VACUUM

temperature rise: +/-10% tolerance. inlet port and 29.92 In Hg atmospheric backpressure (abs).

2

Page 70: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

- For proper use, the blower should be equipped with inlet filter and safety valve; other accessories a vailable on request. - Ambient temperature from +5° to +104° F. - Specifications subject to change without notice.

Model Maximum

flow cfm

Installed power

Hp Size

Maximum differential pressure

∆∆∆∆p ( In Hg )

Noise level Lp dB (A)

(1)

Weight (2)

60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm Lbs

K07-TD 296 245

7 ½ NEMA 182-4TC

6.6 9.6 78.6 76.6 156.50 NEMA 213-5TC

10 NEMA 213-5TC 9.9

12.5

78.9

76.9

156.50

15 NEMA 213-5TC

13.2 79.5 156.50

NEMA 254-6TC 160.90

K08-TD 368 305 10 NEMA 213-5TC 7.0 10.3 79.3 77.3 169.80

15 NEMA 213-5TC

12.5 12.5 79.9 77.9 169.80

NEMA 254-6TC 178.60

K09-TD 467 387 15

NEMA 213-5TC 7.7 11.4 82.2 80.2

196.20 NEMA 254-6TC 201.70

20 NEMA 254-6TC 11.7 12.5

82.5 80.5

201.70 25 NEMA 284-6TSC 13.2 198.40

K10-TD 571 473 15

NEMA 213-5TC 6.3 9.6 85.9 83.9

202.80

NEMA 254-6TC 209.50

20 NEMA 254-6TC 9.6 13.2

86.2 84.2

209.50 25 NEMA 284-6TSC 13.2 205.00

K11-TD 642 532

20 NEMA 254-6TC 6.6 10.3 86.7 84.7 246.80 25 NEMA 284-6TSC 9.6

13.2

87.2

85.2

244.70

30 NEMA 284-6TSC 11.0

40 NEMA 324-6TSC 12.5 88.1 264.50

K12-TD 716 593 25 NEMA 284-6TSC 6.3 10.3 87.5 85.5 242.5 30 NEMA 284-6TSC 8.8 13.2 88.0 86.0 242.5 40 NEMA 324-6TSC 12.5 - 88.4 - 262.3

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744. (2) Value is refered to weight of the machine without electric motor

For dimensions, please refer to drw:

SCL K07 / K08 / K09 / K10 / K11 / K12TD SERIES - GOR RANGE

SN 2180-4 1/2

TECHNICAL CHARACTERISTICS - Aluminium alloy construction - Smooth operation - High efficiency impeller - Maintenance free - Mountable in any position - G1/8” female thread on both

suction and discharge silencer port flanges

OPTIONS - Special voltages (IEC 38) - Surface treatments

ACCESSORIES - Inlet and/or inline filters - Additional inlet/outlet silencers - Safety valves - Flow converting device - Optional connectors

G 1/8”

70 REGENERATIVE BLOWERS - VACUUM

87.7 244.70

86.5

82.8

SI1971

Page 71: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Curves refer to air at 68° F temperature, measured at inlet port and 29.92 In Hg atmospheric backpressure (abs). Values for flow, power consumption and temperature rise: +/-10% tolerance. Data subject to change without notice.

CAPA

CITY

A

BSO

RBED

PO

WER

TE

MPE

RATU

RE IN

CREA

SE

SCL K07 / K08 / K09 / K10 / K11 / K12TD SERIES - GOR RANGE

SN 2180- 2/2

200

0 1

2 3 4 5 6 7 8

9 10 11 12 13 14

p I

n Hg

0 1

2 3 4 5 6 7 8 9

10 11 12 13 14

p I

n H

g

0 20 40 60 80 100 120 140 160 °F 180

0

20

40

60

80

100

120

140

200

160

In W

G

K07-TD

K09-TD

K11 -TD

K08-TD

K10 -TD

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

p I

n H

g

100 200 300 500 400 600 700 0

20

40

60

80

100

120

140

In W

G

160

200

K07-TD

K08-TD

K09-TD

10

25 15

20

15

25

10 15

20

K10-TD

K11-TD

20

40

30

25

7 1/2

15

0 cfm 800

K12-TD

25

30

40

60 Hz

0

20

40

60

80

100

120

140

160

In W

G

K11 -TD

K08-TD

K09-TD

K10 -TD

K07-TD

Hp 0 10 20 30 5 15 25 35

K12 -TD

60 Hz

K12 -TD

60 Hz

cfm 0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

p I

n H

g

0 1

2 3 4 5 6 7 8

9 10 11 12 13 14

p I

n Hg

0 20 40 60 80 100 120 140 160 180 °F 0

20

40

60

80

100

120

140

160

200

In W

G

K07-TD

K09-TD

K11 -TD

K08-TD

K10 -TD

0 1

2 3 4 5 6

7 8 9

10 11 12 13 14

p I

n Hg

0

20

40

60

80

100

120

140

160

In W

G

200

K07-TD

K10 -TD K08-TD

K11-TD K09-TD

20

25 20

15 10

10

15

15

20

0 100 200 300 400 500 600 700

K12 -TD

30

25

7 1/2

50 Hz

Hp 0 5 20 25

0

20

40

60

80

100

120

In W

G

140

160

200

10 15

K11 -TD

K08-TD

K09-TD

K10 -TD

K07-TD

30

50 Hz

K12 -TD

K12 -TD

50 Hz

71REGENERATIVE BLOWERS - VACUUM

4

Page 72: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

- For proper use, the blower should be equipped with inlet filter - Ambient temperature from +5° to +104°F. - Specifications subject to change without notice.

Model Maximum

flow cfm

Installed power

Hp Size

Maximum differential pressure

∆p ( In Hg )

Noise level Lp dB (A)

(1) Weight

(2) 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm Lbs

25 12.5 15.5 86.9 84.9 K09-TT 423 351 30

NEMA 284-6TSC 15.5 - 87.2 -

354

25 - 14.7 - 85.5

30 NEMA 284-6TSC

13.2 16.2 87.8 85.8 365

K10-TT 526 436

40 NEMA 324-6TSC 16.2 - 88.1 - 380

30 NEMA 284-6TSC - 14.7 - 85.8 430 K11-TT 597 495 40 NEMA 324-6TSC 17.0 17.0 88.1 86.1 434

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744. (2) Value is refered to weight of the machine without electric motor

For dimensions, please refer to drw: SS II 2211 8800

SCL K09 / K10 / K11TT SERIES - GOR RANGE

SN 2784-4 1/2

TECHNICAL CHARACTERISTICS - Aluminium alloy construction - Smooth operation - High efficiency impeller - Maintenance free - G1/8” female thread on both

suction and discharge silencer port flanges

OPTIONS - Special voltages (IEC 38) - Surface treatments ACCESSORIES - Inlet and/or inline filters - Additional inlet/outlet silencers - Optional connectors

G 1/8”

72 REGENERATIVE BLOWERS - VACUUM

and safety valve; other accessories available on request.

Page 73: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

- Curves refer to air at 68° F temperature, measured a inlet port and 29.92 In Hg atmospheric backpressure (abs). - Values for flow, power consumption and t emperature rise: +/-10% tolerance. - Data subject to change without notice.

SCL K09 / K10 / K11TT SERIES - GOR RANGE

SN 2784-4 2/2

CAPA

CITY

A

BSO

RBED

PO

WER

TE

MPE

RATU

RE IN

CREA

SE

p I

n Hg

40

200 300 400 500 6000

20

40

60

80

100

120

140

160

180

200

60 Hz260

K10-TT

In W

G

K09-TT

30

25

K11-TT

1 2

3

4

5

6

7

8

9

1 0

11

12

1 3

14

15

1 6

17

1 8

1 9

220

30

40

Hp

K10-TT

0 5 10 15 20 25 30 35 400

20

40

60

80

100

120

140

160

180

60 Hz260

0 1 2 3 4 5 6 7 8 9

p I

n Hg

10 11 12 13 14 15 16 17

In W

G

200

19 18

K09-TT

K11-TT

20

40

60

80

100

120

140

160

180

0 20 40 60 80 100 120 140 160 180 200 220 240°F0

p I

n Hg

0 1 2 3 4 5 6 7 8 9

10 11

15 16

26018

12 13 14

In W

G

200

17

19

K09-TT K11-TT

K10-TT

60 Hz

0cfmcfm700

p I

n Hg

2000

20

40

60

80

100

120

140

160

180

200

260

In W

G

1 2

3

4

5

6

7

8

9

1 0

11

12

1 3

14

15

1 6

17

1 8

1 9

220

300 400 500 600

K09-TT

25

K11-TT

30

40

K10-TT

25

Hp300

20

40

60

80

100

120

140

160

180

260

0 1 23456789

p I

n Hg

1011121314151617

In W

G

200

1918

0 5 10 15 20 25

K10-TT

K09-TT

K11-TT

20

40

60

80

100

120

140

160

180

0 20 40 60 80 100 120 140 160 180 200 220 240°F0

p I

n Hg

0 1 23456789

1011

1516

26018

121314

In W

G

200

17

19 50 Hz

K10-TT

K11-TT

K09-TT

50 Hz

50 Hz

0

30

73REGENERATIVE BLOWERS - VACUUM

t

Page 74: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

5

7

1

11

6

2

810

9

48

10

9

7

6

3

1

11

From a wide range of accessories, thecustomer can select the most suitable for

machine

1 - Cartridge filter2 - Inline filter3 - Filter manifold4 - Relief valve5 - Vacuum valve6 - Check valve7 - Control valve8 - Pressure / Vacuum gauge9 - Sleeve10 - Flexible hose11 - Additional silencer

ACCESSORIES

Installation Guide

their application. In all cases, FPZ suggests toinstall an inlet filter and safety valve on every

Pressure

Vacuum

74

Page 75: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

ACCESSORIES

Safety Valves SS1401

Single Stage Blowers Two Stage Blowers

The following table is a guide to select the appropriate safety valve. The selections in the table are based on blowers operatat 60 Hz - for 50 hz applications refer to the safety valve data sheets. To select the appropriate safety valve, determine the blower model, horsepower, and whether it is to be used for vacuum or pressure service. If it is desirable to have the valve activate at lower pressures than the maximum rated pressure or vacuum of the blower, a different safety valve might be required (refer to safety valve data sheets). In some cases, two valves are required. .FPZ valves are supplied uncalibrated. All safety valves include detailed instructions on how to calibrate and install the valve.

Model HP Safety Valve Vacuum

Pressure Model HP Vacuum

Pressure

K03-MS 3/4 VRL6 VRL6 15DH ALL VRL6 VRL6K04-MS ALL VRL6 VRL6 ALL VRL6 VRL6K05-MS ALL VRL6 VRL6 30DH ALL VRL6 VRL6K06-MS 3 VRL6 VRL8 40DH ALL VRL6 VRL6K06-MS 4 VRL6 VRL6 K07-MD 3 VRL6 VRL6K06-MS 5 1/2 VRL6 VRL6 K07-MD 4 VRL6 VRL6K06-MS 6 1/5 VRL6 VRL6 K07-MD 5 1/2 VRL6 VRL6K07-MS 4 VRL8 VRL8 K07-MD 7 1/2 VRL6K07-MS 4 VRL8 VRL8 K07-MD 7 1/2 VRL6K07-MS 5 1/2 VRL6 VRL8 K08-MD 5 1/2 VRL6 VRL6K07-MS 7 1/2 VRL6 VRL6 K08-MD 7 1/2 VRL6 VRL6K07-MS 10 VRL6 VRL6 K08-MD 10 VRL6 VRL6K08-MS 5.5 VRL8 VRL9 K08-MD 15 - VRL6-HPK08-MS 7 1/2 VRL8 VRL8 K09-MD 5 1/2 VRL8 VRL8K08-MS 10 VRL6 VRL8 K09-MD 7 1/2 VRL6 VRL6K08-MS 15 VRL6 VRL6 K09-MD 10 VRL6 VRL6K09-MS 7 1/2 VRL9 VRL9 K09-MD 15 - VRL6-HPK09-MS 10 VRL8 VRL8 K10 -MD 7 1/2 VRL8 VRL8K09- 10 VRL8 VRL8 7 1/2 VRL8 VRL8K09-MS 15 VRL6 VRL8 K10-MD 10 VRL6 VRL6K09-MS 20 VRL6 VRL6 K10-MD 15 VRL6 VRL6K10-MS 7 1/2 VRL9 VRL9 K10-MD 20 - VRL6-HPK10-MS 10 VRL9 VRL9 K11-MD 10 VRL8 VRL8K10-MS 15 VRL8 VRL8 K11-MD 15 VRL6 VRL8K10-MS 20 VRL6 VRL8 K11-MD 20 VRL6 VRL6-HPK10-MS 25 - VRL6 K11-MD 25 - VRL6-HPK11-MS 10 VRL9 VRL9 K12-MD 15 VRL8 VRL8K11-MS 15 VRL9 VRL9 K12-MD 20 VRL6 VRL6K11 MS 15 VRL9 VRL9 K12 MD 20 VRL6 VRL6K11-MS 20 VRL8 VRL8 K12-MD 25 - VRL6-HPK11-MS 25 VRL VRL8 K04-TD 2 VRL6 VRL6K12-MS 15 VRL9 VRL9 K04-TD 3 VRL6 VRL6K12-MS 20 VRL9 VRL9 K05-TD 3 VRL6 VRL6K12-MS 25 VRL8 VRL8 K05-TD 4 VRL6 VRL6K05-TS ALL VRL8 VRL8 K05-TD 5 1/2 VRL6 VRL6K06-TS 5 1/2 VRL9 VRL9 K06-TD 5 1/2 VRL6 VRL8K06-TS 7 1/2 VRL8 VRL8 K06-TD 7 1/2 VRL6 VRL6K06-TS 10 VRL6 VRL8 K06-TD 10 VRL6 VRL6K07-TS 7 1/2 VRL9 VRL9 K07-TD 7 1/2 VRL8 VRL8K07-TS 10 VRL9 VRL9 K07-TD 10 VRL6 VRL6K07-TS 15 VRL8 VRL8 K07-TD 15 VRL6 VRL6K08-TS 7 1/2 N.A N.A. K08-TD 7 1/2 VRL8 VRL8K08-TS 10 VRL9 (2) VRL9 K08-TD 10 VRL8 VRL8K08-TS 15 VRL9 VRL9 K08-TD 15 VRL6 VRL6K09-TS 15 (2) VRL9 (2) VRL9 K09-TD 20 VRL6 VRL8K09-TS 20 VRL9 VRL9 K09-TD 25 VRL6 VRL6K09-TS 25 VRL8 VRL9 K10-TD 15 VRL9 VRL9K10-TS 15 (2) VRL9 (2) VRL9 K10-TD 20 VRL8 VRL8K10-TS 20 (2) VRL9 (2) VRL9 K10-TD 25 VRL6 VRL8K10-TS 25 VRL9 VRL9 K11-TD 20 VRL9 VRL9K11-TS 25 (2) VRL9 (2) VRL9 K11-TD 25 VRL8 VRL8K11-TS 30 (2) VRL9 (2) VRL9 K12-TD 25 VRL9 VRL9K12-TS 30 (3) VRL9 (3) VRL9 K12-TD 30 VRL8 VRL8

Valve selections are based on 60 Hz operation and refer to air having a density equal to 0.075 lbs / cu. Ft and inlet temperar ture of 68 deg F. Data is subject to

change without notice.g

75

ing

Safety Valve Safety Valve Safety Valve

VRL6-HP

R20-MD

8

Page 76: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Capacity

Pres

sure

/ V

acuu

m

180

Scfm

150

120

90

60

In WG

30

0

Psig

210

240

0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200

In H g

270

0

2

4

6

8

10

12

14

16

18

0

1

2

3

4

5

6

7

8

9

TYPE ND D A B H WEIGHT (Lbs)

VRL6 2” 2” NPT 4.02 6.90 0.47 1 .9

VRL8 3” 3” NPT 5.31 7.48 0.59 4.2

VRL9 4” 4” NPT 6.30 8.11 0.71 5.7

ØD

ØA

B

ØD

H

H

OPERATING RANGE

OVERALL DIMENSIONS

• Dimensions in inches.

• Specifications subject to change without prior notice.

VRL6 VRL8 VRL9

The VRL valves are designed to protect blowers and / or motors from over pressurization or excess vacuum. When there is over pressurization, the valve opens and discharges to the outside. When there is excess in vacuum, the valve opens and takes flow from outside. The valves have been designed for low pressure / low vacuum, with minimal difference between the initial value at which the valve begins to open and its fully opened position. The valves are supplied with 2 different springs to maximize their efficiency. These compact valves, made of aluminum al loy, are both easy to install and calibrate. The valves are designed to operate in a wide range of capacities. The VRL can be plumbed to divert excess primary flow through a secondary external outlet when working in pressure conditions or to pipe ndary flow when working in vacuum.

a seco in

Maximum efficiency is achieved by keeping operating values (flow versus pressure or vacuum) within the operating range (shaded area on graph). Capacity refers to air having a density equal to 0.075 lbs./cu.ft .

VRL6 VRL8 VRL9

SN 1733 1/1 -5

ACCESSORIES

Safety Valves

76

Page 77: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Pres

sure

/ V

acu

um

In Hg

17

18

19

20

21

22

23

TYPE ND D A B H WEIGHT (Lbs)

VRL6 - H.P. 2” 2” NPT 3.94 6.57 0.47 2.1

VRL8 - H.P. 3” 3” NPT 5.31 7.48 0.59 4.2

OVERALL DIMENSIONS

• Dimensions in inches.

• Specifications subject to change without prior notice.

The VRL H.P. valves are designed to protect blowers and / or motors from over pressurization or excess vacuum. When there is over pressurization, thevalve opens and discharges to the outside. When there is excess in vacuum,the valve opens and takes flow from outside. The valve have been designed for low pressure / low vacuum, with minimaldifference between the initial value at which the valve begins to open and itsfully-opened position. These compact valves, made of aluminum alloy, are both easy to install andcalibrate. The valves are designed to operate in a wide range of capacities.The VRL H.P. can be plumbed to divert excess primary flow through asecondary external outlet when working in pressure conditions or to pipe-in a secondary flow when working in vacuum. Maximum efficiency is achieved by keeping operating values (flow versuspressure or vacuum) within the operating range (shaded area on graph). Capacity refers to air having a density equal to 0.075 lbs./cu.ft .

Psig

9

9.5

10

10.5

11.5

11

8.5

8

Capacity

In WG OPERATING RANGE

scfm 220

240

260

280

300

320

0 200 400 600 800 1000 1200 1400 1600 1800

VRL6 - H.P. VRL8 - H.P.

ØD

ØA

B

ØD

H

H

ACCESSORIES

High Pressure Safety Valves

77

VRL6 - H.P. VRL8 - H.P.

SS1401

SS1401

Page 78: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

78

Inline Filters SS1 0

ACCESSORIES

DIMENSIONS (Inches)

Polyester Element

NPT A B C D E F G Used on Models Approx Wt. Lbs

CSL-843-050HC ½” 4 3/8 9/16 5 7/8 2 ½ 9/16 5 3 ¼ 10DL 3

CSL-843-075HC ¾” 4 3/89/16 5 7/8 2 ½ 9/16 5 3 ¼ 15DH 3

CSL-843-100HC 1” 4 3/8 ¾ 5 7/8 2 ½ ¾ 5 3 ¼ 06 3

CSL-843-125HC 1 ¼” 4 3/8 ¾ 5 7/8 2 ½ ¾ 5 3 ¼ K03-MS, R20-MD

CSL-849-150HC 1 ½” 6 ½ ¾ 7 5/16 4 ½ ¾ 6 13/16 5 ¼ K04-MS, K04-TD, 30DH, 40DH 5

CSL-851-200HC 2” 10 ¼ ¾ 8 ¾ 5 ¾ 7 5/8 9 ¼ K05-MS, K06-MS, K05-TD, K06-TD, K07R-MD,

K08R-MD 15

CT-235P-300C 3" 18 13/16 9 7/8 13 1/2 16 4/5 13 1/8 10 14 K05-TS, K06-TS, K07-MS, K08-MS,

K07-TD, K08-TD 30

CT-235P-400C 4" 18 13/16 9 7/8 13 1/2 16 4/5 13 1/8 10 14 K09-MS, K10-MS, K09-MD, K10-MD, K11-MD, K12-

MD, K09-TD, K10-TD 29

CSL-335P-400* 4" 27 1/8 3 14 18 1/2 3 12 15 K07-TS, K08-TS, K11-MS, K12-MS,

K11-TD, K12-TD 30

CT-275P-500C 5” 18 ¼ 16 19 14 3/8 9 7/8 14 ¾ 20 K09-TS, K10-TS 50

CTD-375P-500C 5” 25 3/8 16 19 21 1/2 17 14 ¾ 35 K11-TS, K12-TS 60

Vacuum regulator & gauge available Various media available Epoxy coated housings Special connections Available in Stainless Steel Activated carbon prefilter to reduce

odor Alternate Top-to-canister fastening

system for low pressure or pulsating systems

Polyester: 99%+ removal efficiency standard to 5 micron Stainless steel torsion clips for durability Rugged all steel construction with Baked enamel finish Low pressure drop Positive sealing O-ring seal system Large dirt holding capacity and easy field cleaning, especially when mounted horizontally or inverted Fully-drawn one piece canister Filter change out differential: 10”-15” H2O Over Initial Delta P

FPZ inline filters are typically used in vacuum applications to prevent debris from entering the blower. Inline filters consist of a metal housing with a metal cover retained by quick - change clamps for easy servicing of the element. Polyester elements are recommended for humid applications.

CT Series

Service area needed

Dimension tolerance + 1/8”

CSL Series Service area needed

Inlet (process)

Service area needed

B

G C

F

Connect to blower

A D

B

A

G

E

* Male x male npt connectionsDimensions for reference only

3

4 1

Page 79: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

ACCESSORIES

Inlet FiltersSS1401

79

*FL 10 utilizes 15 micron paper element and does not include tubular silencers

Polyester Element

NPT A

Dimensions (Inches)

B C

Used on Models Approx Wt. Lbs

FS-15-050 ½” 4 1 ½ 6 10DL 2

FS-15-075 ¾” 4 1 ½ 6 15DH 2

FS-15-100 1” 4 1 ½ 6 O6 2

FS-19P-125 1 ¼” 6 5/8” 1 5/8” 6 K03-MS, 20 D

FS-19P-150 1 ½” 6 5/8” 1 5/8” 6 K04-MS, K04-TD, 30DH, 40DH 4

FS-31P-200 2” 7 ¼” 2 ¼” 10 K05-MS, K05-TD 8

FS-231P-200 2” 12 ¼” 2 ¼” 10 K06-MS, K06-TD, K07R-MD, K08R-MD 14

FS-231P-300 3" 13” 3” 10” K07-MS, K05-TS, K07-TD 15

FS-235P-300 3" 13” 3” 16” K08-MS, K06-TS, K08-TD 29

FS-235P-400 4" 14” 4” 16” K09-MS, K10-MS, K09-MD, K10-MD, K11-MD, K12-MD, K09-TD, K10-TD

30

FS-245P-400 4" 14” 4” 16” K07-TS, K08-TS, K11-MS, K12-MS, K11-TD, K12TD 31

FL10* NA 14 3/8” 1 3/8” 16 3/16” K09-TS, K10-TS, K11-TS, K12-TS, 18

Noise attenuation may vary due to application

Polyester: 99%+ removal efficiency standard to 5 micron Fully drawn weather hood - no welds to rust or vibrate apart Tubular silencing design - tube is positioned to maximize

attenuation and air flow while minimizing pressure drop Durable carbon steel construction with baked enamel finish and powder coated weather hood Interchangeable elements: Polyester, Paper Low pressure drop center bracket and outlet pipe design Filter change out differential: 10”-15” H2O Over Initial Delta P

FEATURES & SPECIFICATIONS

FPZ inlet filters are used for pressure applications. The inlet filters combine filtration and sound attenuation into a compact package. Inlet filters consist of a filter cartridge enclosed by a carbon steel weather hood. Elements are easily serviceable by simply removing the weather hood.

Dimension tolerance + 1/8”

TYPICAL NOISE ATTENUATION – FS SERIES

OCTAVE BAND CENTER FREQUENCIES - Hz

ATT

ENU

ATI

ON

- db

INLET

OUTLET

FEATURES & SPECIFICATIONS OPTIONS (Inquiries Encouraged)

C

A

B

Various media available 1/8” & 1/4” tap holes Pressure Drop Indicator Available in Stainless Steel Epoxy coated housings Hot dipped galvanized housings Special connections, NPT

3R -M

Page 80: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

FEATURES Monitors Filter Continuously

Easy Filter Maintenance

Filter Element Life Maximized

Downtime Reduced

Graduated Restriction Readings

has left. This is a convenient and inexpensive solution to receiving the maximum usage from every element. The yellow indicator in the filter monitor gauge drops as the dirt accumulates on the filter element. The element is ready for change out or servicing when the yellow indicator reaches the red zone. This allows you to determine the condition of the filter element even after the equipment has been shut down. The element should be serviced or replaced at the

SPECIFICATIONS

Normal Clean Filter

Gauge shows how much capacity

remains

Gauge shows filter element capacity

used. Filter requires service

GAUGE IN ACTION

Note: The monitor gauge has a 1/8” MPT connection. It is

Part No: VG-020-013 filter element restriction and how much life the element The dirty filter indicator shows the amount of

maximum pressure drop of 10-15 inches of water.

mounted either on the weatherhood or on the outlet pipe

ACCESSORIES

depending on the filter assembly. Used for pressure applications only.

Dirty Filter Indicator

If the blower is operating at its maximum rated pressure,contact the factory for recommended setting.

80

SS1401 1/1

Page 81: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

This all aluminum device is simple in both design and operation. Change of flow direction is attain an electronically or pneumatically activated diverter.

C B A max

I

I

F

F

O

M

H

L

DN

0 20 40 60 80 100 120

0 0,5 1,0 1,5 mbar psig

VS 6

VS

m3/hcfm

“O” execution

TYPE DN A B C F H I L M O VS 6 2” 15.43 (1) 16.42 (2) 4.13 4.29 M6 4.33 2 x int.3.35 3.94 6.38 3.46 VS 8 3” 19.09 (1) 20.08 (2) 4.02 5.28 M6 6.3 4 x int.4.72 5.91 8.27 4.33

Overall dimensions refer to “O” execution without flanges

For the dimensions of the other executions pls see: SS II 11 778877 Executions O/P SS II 11 778888 Executions Y/H/K with pneumatic

control SS II 22002211 Executions Y/H/K with electrical

control

(2) Electronically activated(3) Pneumatically activated

50

100

200

300

400

500

600

800

1000

1400

0

50

100

200

300

400

500

600

800

VS 8

Pressure drop per side (inlet/outlet)

Dimensions in inches. Tolerance on given values ±10 % - unbinding and can be changed without prior not .

Available connection - TF threaded flange GAS (G 1 ½”, G 2”, G3”); - TF threaded flange NPT (NPT 1 ½”, NPT 2” , NPT 3”); - See SU 0012.

Other execution P - Y - H - K

With piped outlet

With double control

With collector and double control With double collector and double control

P Y

H K

EXECUTION

O / P Y / H / K

Electrical control

Thrust solenoid Working ratio 60% of cycle time Max. cycle duration 5 min. Max. activated time 3 min. Power rating 56 W 120 W (3) Standard supply voltages V: 24 DC–110 AC–220 AC

Pneumatic control Thrust air cylindrer Double effect Max pressure 10 Bar Air consumption 0.02 litres/cycle Operating temperature -5°C ~ +70 °C

(3) Only for VS6 (dp max. +350/-350 mbar)

SN 2616- 1/1

ACCESSORIES

Flow Converting Devices81

V6 / VS82

ice

ed by

Page 82: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

SN 2048-2

VK - FLANGE CONNECTOR FOR VRL VALVES This VK flange accessory allows direct connection of the VRL relief valves to the cover of the SCL "K" model blowers;

Fig. 1

R

G

S1

H

I

S

Fig. 2

S1

G

I

R

S H

VK flange

VRL

SCL K

SCL K

CK accessory

VK flange

VRL

Fig. 2

ØD

I

R

S H

S1

Fig. 1

R

ØD

I

S

S1

H

PK - FLANGED TUBE CONNECTOR FOR SCL K The PK accessory allows connection of the "K" Series blowers direct CHARACTERISTICS Flange in aluminium alloy with tube stub connection.

SCL K

MF accessory PK accessory

Supplied as a kit for mounting (with gasket and screws with ve Parts List in table.

ACCESSORIESVK / PK Flange Connectors

Model DN G H I R S S1 Fig. Parts List VK 5 1” 1/2 1” ½ NPT 1.18 3.62 0.26 0.59 0.39 SP 1552 VK 6 2” 2” NPT 1.97 4.33 0.33 0.75 0.39

1 SP 1553

VK 6A 2“ 2” NPT 2.34 5.12 0.35 0.75 0.43 SP 1611 VK 8 3” 3” NPT 1.69 5.12 0.35 0.83 0.43 SP 1554 VK 9 4” 4” NPT 1.81 5.90 0.35 0.90 0.43

2 SP 1555

Dimensions in Inches

Model DN D H I R S S1 Fig. Parts List PK 5 1” 1/2 1.89 1.18 3.62 0.26 0.79 0.39 SP 1543 PK 6 2” 2.36 1.97 4.33 0.33 1.38 0.39

1 SP 1544

PK 6A 2” 2.36 2.34 5.12 0.35 1.38 0.43 SP 1609 PK 8 3” 3.46 1.69 5.12 0.35 0.94 0.43 SP 1545 PK 9 4” 4.48 1.81 5.90 0.35 1.06 0.43

2 SP 1546

Dimensions in InchesFig. 2Fig. 1

either in pressure or vacuum. Note: VK flanges usable on K-MS and K-TS blowers in vacuum or pressure. K-MD useable in vacuum only.

Note: PK flanges usable on K-MS, K-TS, K-TD blowers in vacuum or pressure. K-MD useable in vacuum only.

82

ly to the process line without use of the intake or outlet manifolds.

wrench), please see the respecti

Page 83: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

CA MANIFOLD FOR FA/FL FILTERS 90° wide radius PVC manifold with flanged connection and unthreaded tube end. Working temperature -20° to +40°C ( -5° ÷ + 1 05 °F).

ØD

B

A

S

R=2D

Fig. 2 I R

Fig. 3

R

I

Fig. 1 I

γ

R

ACCESSORIES

CA / CK Manifolds

I4

I2

C

I1

I3

B

I2

I1

G

I1 I2

I4 I3 B

I1 I2

C

øF

E1

øDA

øD

A

E

A

E

B

øD

E

øD

G

22.5

Int.I

9022.5

90°

C

ø

øF

22.5° Int.I

90°

22.5°

90°

G

C

Dimensions in inches - unbinding and can be changed without prior notice.

Fig. 1

Fig. 2

CK MANIFOLD

90° aluminium manifold for “K” models suppli

Dimensions in inches - unbinding and can be changed without prior notice.

83

Type DN A B D S I R Y Fig.CA4 1.25" 8.66 3.54 1.65 0.59 2.95 0.28 30O 1

CA4V 1.25" 8.66 3.54 1.65 0.59 2.52 0.28 - 2

CA5 1.5" 10.24 4.33 1.89 0.59 3.35 0.28 45O 1

CA5V 1.5" 10.24 4.33 1.89 0.59 2.95 0.28 - 2

CA6 2" 12.60 5.31 2.36 0.59 3.35 0.28 45O 1

CA6V 2" 12.60 5.31 2.36 0.59 3.35 0.28 - 2

CA8 3" 14.96 7.28 3.46 0.59 4.72 0.28 -

CA9 4" 15.75 9.25 4.45 0.79 5.91 0.35 - 3

CA10 5" 17.72 11.81 5.51 0.79 8.27 0.71 -

Type DN A B C D E E1 F G I I1 I2 I3 I4 Fig.CK4 1.25" 2.72 3.33 2.20 1.15 0.27 0.45 0.27 M6 - 0.57 0.57 2.76 2.76

CK5 1.5" 3.15 3.94 2.20 1.69 0.27 0.45 0.27 M6 - 0.69 0.69 3.35 3.35 1

CK6 2" 3.62 4.65 2.72 2.16 0.31 0.51 0.35 M8 - 0.73 0.95 3.92 4.10

CK8 3" 5.71 5.71 4.31 2.95 0.39 - 0.35 M8 5.12 - - - -

CK9 4" 6.50 6.50 5.22 3.54 0.39 - 0.35 M8 5.90 - - - - 2

CK10 5" 8.66 8.66 7.56 5.04 0.39 - 0.35 M8 7.48 - - - -

ed in a kit containing the gasket and bolts.

SS1401

SS1401

Page 84: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

ACCESSORIES

BA

C

eGauges, Check Valves, Silencers, Enclosures

Dimensions in inches - unbinding and can be changed without prior notice.

Part # Used on models A B CIH1 SCL K03-MS 13.4 18.2 15.8IH3 SCL K04-MS 14.3 19.7 16.5IH5 SCL K05-6 MS + 30-40 DH 16.9 26.8 21.3IH7 SCL K07-8 MS / MD 31.7 64.4 26IH8 SCL K07-8 TD 31.7 64.4 26IH9 SCL K07-8 TS 31.7 64.4 26

IH10 SC L K09-1 MS/MD 31.7 67.2 30IH11 SCL K09-10 TD 31.7 67.2 30IH12 SCL K11-TD 31.7 67.2 30IH13 SCL K09-11 TS 31.7 67.2 31.5

ØD ØC

A BE

F

TYPE D A B C E F SS 4 SS 5 SS 6 SS 8 SS 9

Steel manufactured (apart from SI 9 / SS 9 - entirely in aluminium) wthe noise is reduced

7.5 5.5 2.8 2 0.6lbs 0.8 1” 1/4

7.9 6.7 3.1 1.2 0.8

0.8

0.8 0.8

1.1 1.3

9.9 4.8

1” 1/2 9.1 7.9 3.5 2” 19.1 15.7 6.0 3.3 3” 18.3 16.9 6.7 1.1

1.2

4”

B

1/4 NPT

øA

Gauges are important for monitoring the operating pressure or vacuum of the blower. Gauges should be positioned as close to the blower as possible.

Gauges

Dimensions in inches. Tolerance on given values ± 1 0% - unbinding and can be changed without prior notice.

Dimensions in inches. Tolerance on given values ± 1 0% - unbinding and can be changed without prior notice.

Check Valves backflow into the blower and are supplied in bronze or brass.

Silencers

Sound Enclosures

Silencers provide additional sound attenuation.

sound absorbing polyurethane element.

Swing check valves allow air to flow in one direction. These valves prevent

A

B

C

Dimensions in inches. Tolerance on given values ± 1 0% - unbinding and can be changed without prior notice.

2

84

ith

Part number

Duty Scale A B

VG25-60 Vacuum 0-60" H2OVG25-200 Vacuum 0-200" H2O VG25-300 Vacuum 0-300" H2O 2.88 2.59PG25-60 Pressure 0-60" H2O

PG25-200 Pressure 0-200" H2OPG25-300 Pressure 0-300" H2OPG20-15 Pressure 0-15 psi 2.25 1.9

SS1310

Part Number

NPT A B C

CV075 0.75" 2.4CV10 1" 2.8 1.9 2.7

CV125 1.25" 3.2 2.2 3.2CV15 1.5" 3.6 2.5 3.5CV20 2" 4.3 3.1 4.2CV30 3" 5.8 4.2 6.1CV40 4" 6.9 5.5 7.1

Page 85: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

TIPOTYPE DN D L

MF 1 1/2” 20 200MF 2 3/4“ 26 200MF 3 1” 32 200MF 4 1” 1/4 45 200MF 5 1” 1/2 50 250MF 6 2” 64 250MF 8 3” 89 330MF 9 4” 114

MF 10 5” 140 330

TIPOTYPE D H I 1 I 2 R 1 R 2 S

TF 3 G 1” 18 55 - 6.5 - 10TF 4 G 1” 1/4 18 75 - 6.5 - 10

TF 4V G 1” 1/4 18 64 - 6.5 - 10TF 5 G 1” 1/2 18 85 - 6.5 - 10

TF 5V G 1” 1/2 18 75 - 6.5 - 10TF 6 G 2” 18 85 - 6.5 - 10TF 8 G 3” 25 - 120 - 6.5 13TF 9 G 4” 25 - 150 - 9 13

Dimensions in mm. Tolerance on given values ± 10% - unbinding and can be change

FLEXIBLE SLEEVESteel reinforced rubber - coated fibreglass flex tubing, including 2adjustable hose clamps. Working temperature: -55 ÷ +176 °C (-67 ÷+350 °F). Maximum working pressure: 3 bar (44 psi).

THREADED FLANGEThreaded flange in aluminum alloy.

Fig. 1Mat.: Al

Fig. 3Mat.: Fe

Fig. 2Mat.: Al

TIPOTYPE DN D G H I R S Fig. TIPO

TYPE DN D G H I R S S1 Fig.

MP 1 1/2” 21 G 1/2” 100 - - 85 MP 5V 1” 1/2 48 - 35 75 6.5 25 -MP 2 3/4” 27 G 3/4” 100 - - 85 MP 6 2” 60 - 35 85 6.5 25 -MP 3 1” 33 - 35 55 6.5 25 MP 8 3” 88 - 45 120 6.5 32 - 2MP 4 1” 1/4 42 - 35 75 6.5 25 MP 9 4” 114 4” npt 100 - - 80 - 3

MP 4V 1” 1/4 42 - 35 64 6.5 25 MP 10 5” 140 5” npt 60 210 18 40 8 4MP 5 1” 1/2 48 - 35 85 6.5 25

3

SLEEVEAluminum alloy or steel flanged sleeve coupling.

1

1

Fig. 4Mat.: Fe

L

ØD

R1

SH

R2

I2

D

I1

R

ØD

SH

I IR

ØD

S H

ØD

G

SH

S1ØD

G

IR

S H

ACCESSORIESFlexible Sleeves / Flanges

85

SS1401

d without prior notice.

330

Page 86: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

SINGLE PHASE DUAL VOLTAGE

GENERAL SPECIFICATIONS:

1- Type: Single phase AC MOTOR - IEC 60034 2- Marks: cURus, CE 3- Poles: 2 4- Frequency: 60 Hz 5- Insulation Class: F 6- Enclosure: TEFC 7- Protection: IP 55 8- Thermal Protector: KLIXON 140 °C 9- Service Factor: 10- Max. Ambient: 40°C 11- Duty: Cont. 12- Construction: Aluminium frame

POWER VOLTAGE SPEED FLA STARTING CURRENT

POWER FACTOR CAPACITOR

Hp V min -1 A A cos φ µF

1 115-208/230 3450 13.0 / 0

2 115-208/230 3440

THERMAL PROTECTION NORMALLY CLOSED

THERMAL CUT-OFF

LOW VOLTAGE 115 V - 60 Hz HIGH VOLTAGE 208-230 V - 60 Hz

1/3 115-208/230 3330 1/2 115-208/230 3360 3/4 115-208/230 3450

1 ½ 115-208/230 3330 3 115-208/230 3425 0.85

0.97

0.95

0.90

0.66

0.96 046.1/ 23.0

054.4 / 29.2 24.0 / 12.0 31.5 / 16.0

13.6 / 07.3

09.8 / 04.9 049.4 / 24.7

079.2 / 39.6 154.4 / 78.4

03.5 / 01.7 012.3 / 06.0 0.97 16.0 - 400 V

20.0 - 400 V

50.0 - 400 V

60.0 - 400 V

16.0 - 400 V

31.5 - 400 V

70.0 - 400 V

016.8 / 09.1 04.8 / 02.6

Specifications subject to change without notice. Alternate motor suppliers may be used.

SN 2102-

Single Phase Electric Motors

1. 0

TECHNICAL

7.2

86

3

Page 87: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

.

Specifications subject to change without notice. Alternate motor suppliers may be used.

TECHNICAL

SS1401

YY MIN VOLTAGE Y MAX VOLTAGE

THERMAL PROTECTION NORMALLY CLOSED THERMAL CUT-OFF

WIRING DIAGRAM

U2 V2 W2

U5 V5 W5

U1 V1 W1

U2 V2 W2

U5 V5 W5

U1 V1 W1

** 9 LEADS MOTOR . APPLICABLE TO 20Hp SIZE 132 208-230/460 V - 60 Hz 200/400 V - 50 Hz

∆ MIN VOLTAGE Y MAX VOLTAGE

THERMAL PROTECTION NORMALLY CLOSED THERMAL CUT-OFF

WIRING DIAGRAM

6 LEADS MOTORS. 208-230/460 V - 60 Hz 230/400 V - 50 Hz

87

THREE PHASE MOTORGENERAL SPECIFICATIONS:

1. Type: 3-phase AC Motor IEC 60034 7. Protection2. Marks: cURus, CE 8. Thermal protector: Klixon 150 O C3. Poles: 2 9. Service factor: 1.154. Insulation class: F 10. Max. Ambient 40O C5. Frequency: 60 hz / 50 hz 11. Duty: Continuous6. Enclosure: TEFC 12. Construction: aluminum frame

HP KW SIZE VOLTAGEFLA

208 / 460

POWER FACTOR

cos φVOLTAGE

FLA 230 / 400

(200 V)

POWER FACTOR

cos φ

STARTING CURRENT

RATIO*

CABLE ENTRY

1***

CABLE ENTRY 2

0.33 0.25 63 208-230/460 1.5 / 0.7 0.75 230/400 1.4 / 0.8 0.70 3.9 M16 M20

0.5 0.37 63 208-230/460 2.3 / 1.0 0.79 230/400 2.1 / 1.2 0.73 3.6 M16 M20

0.75 0.55 71 208-230/460 2.7 / 1.2 0.85 230/400 2.6 / 1.5 0.78 3.8 M16 M20

1 0.75 80 208-230/460 3.3 / 1.5 0.84 230/400 3.5 / 2.0 0.78 5.0 M20 M25

1.5 1.1 80 208-230/460 5.0 / 2.3 0.86 230/400 4.5 / 2.6 0.82 5.6 M20 M25

2 1.5 90 208-230/460 6.3 / 2.9 0.82 230/400 6.1 / 3.5 0.82 5.0 M20 M25

3 2.2 90 208-230/460 9.0 / 4.1 0.87 230/400 8.5 / 4.9 0.81 7.1 M20 M25

90 208-230/460 11.2 / 5.9 0.80 230/400 11.8 / 6.8 0.80 7.0 M20 M25

100 208-230/460 12.9 / 6.1 0.85 230/400 11.6 / 6.7 0.85 6.0 M25 M20

5.5 4 100 208-230/460 17.5 / 8.1 0.88 230/400 14.0 / 8.1 0.88 6.2 M25 M20

7.5 5.5 112 208-230/460 20.0 / 9.5 0.86 230/400 19.4 / 11.2 0.85 7.6 M25 M20

112 208-230/460 26.0 / 12.5 0.88 230/400 25.6 / 14.8 0.87 8.2 M25 M25

132 208-230/460 26.5 / 15.3 0.87 230/400 37.5 / 21.7 0.84 6.9 M32 M32

15 11 132 208-230/460 40.0 / 21.7 0.84 230/400 37.5 / 21.7 0.84 6.9 M32 M32

132** 208-230/460 54.0 / 26.0 0.86 200/400 (61.0) / 30.5 0.82 7.0 M32 M32

160 208-230/460 54.0 / 29.8 0.85 230/400 51.6 / 29.8 0.85 8.1 M40 M40

25 18.5 160 208-230/460 63.0 / 34.8 0.87 230/400 60.0 / 34.8 0.87 8.5 M40 M40

30 22.0 160 208-230/460 72.0 / 41.5 0.87 230/400 72.0 / 41.5 0.87 8.4 M40 M40

* FLA x starting current ratio = starting current

** 9 leads motor applicable to 20 hp motors with 132 frame (MS / MD series)

*** Cable entry 1 includes cable gland

60 HZ 50 HZPOWER

4 3

10 7.5

20** 15

Three Phase Electric Motors

IP55

Page 88: k SERIES CATALOG rev 1 01 - H2O Inter Pro · FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268 -0180 usa@fpz.com applications APPLICATIONS Thousands of FPZ blowers

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

PressureOrifice Diameters - Inches

Pressure " H2O 1/32 1/16 1/8 3/16 1/4 5/16 3/8 7/16 1/2 5/8 3/4 1

1 0.0 0.1 0.2 0.5 0.9 1.4 2.0 2.7 3.5 6 7.8 14 22 31 43 56 70 87 105 125

2 0.0 0.1 0.3 0.7 1.2 1.9 2.8 3.8 4.9 8 11 20 31 44 60 79 100 123 149 177

3 0.0 0.1 0.4 0.8 1.5 2.4 3.4 4.6 6.0 10 14 24 38 54 74 96 122 150 182 217

4 0.0 0.1 0.4 1.0 1.7 2.7 3.9 5.3 7.0 11 16 28 43 63 85 111 141 174 210 250

5 0.0 0.1 0.5 1.1 1.9 3.0 4.4 6.0 7.8 12 18 31 49 70 95 124 157 194 235 280

10 0.0 0.2 0.7 1.5 2.8 4.3 6.2 8.4 11.0 18 25 44 69 99 135 176 222 275 332 395

15 0.1 0.2 0.8 1.9 3.4 5.3 7.6 10.3 13.4 21 30 54 84 121 165 215 272 336 407 484

20 0.1 0.2 1.0 2.2 3.9 6.1 8.7 11.9 15.5 25 35 62 97 140 190 248 314 388 469 559

25 0.1 0.3 1.1 2.4 4.3 6.8 9.8 13.3 17.3 28 39 69 108 156 212 277 351 434 525 624

30 0.1 0.3 1.2 2.6 4.8 7.4 10.7 14.5 19.0 30 43 76 119 171 233 304 385 475 574 684

35 0.1 0.3 1.3 2.9 5.1 8.0 11.5 15.7 20.5 33 46 82 128 185 251 328 415 513 620 738

40 0.1 0.3 1.4 3.1 5.5 8.6 12.3 16.8 21.9 35 49 88 137 197 268 351 444 548 663 789

45 0.1 0.4 1.5 3.3 5.8 9.1 13.1 17.8 23.2 37 52 93 145 209 285 372 470 581 703 836

50 0.1 0.4 1.5 3.4 6.1 9.6 13.8 18.7 24.5 39 55 98 153 220 300 392 496 612 740 881

55 0.1 0.4 1.6 3.6 6.4 10.0 14.4 19.6 25.7 41 58 103 160 231 314 411 520 641 776 924

60 0.1 0.4 1.7 3.8 6.7 10.5 15.1 20.5 26.8 43 60 107 167 241 328 429 542 670 810 964

65 0.1 0.4 1.7 3.9 7.0 10.9 15.7 21.3 27.9 45 63 111 174 251 341 446 564 697 843 1003

70 0.1 0.5 1.8 4.1 7.2 11.3 16.3 22.1 28.9 46 65 116 181 260 354 463 585 723 874 1041

75 0.1 0.5 1.9 4.2 7.5 11.7 16.8 22.9 29.9 48 67 120 187 269 366 479 606 748 905 1077

80 0.1 0.5 1.9 4.3 7.7 12.1 17.4 23.6 30.9 50 70 124 193 278 378 494 625 772 934 1112

85 0.1 0.5 2.0 4.5 8.0 12.4 17.9 24.4 31.6 51 72 127 199 285 390 509 644 795 962 1145

90 0.1 0.5 2.0 4.6 8.2 12.8 18.4 25.1 32.7 53 74 131 204 294 401 524 663 818 990 1178

95 0.1 0.5 2.1 4.7 8.4 13.1 18.9 25.7 33.6 54 76 134 210 302 412 538 680 840 1016 1210

100 0.1 0.5 2.2 4.9 8.6 13.5 19.4 26.4 34.5 55 78 138 215 310 422 551 698 861 1042 1241

105 0.1 0.6 2.2 5.0 8.8 13.8 19.9 27.0 35.3 57 79 141 221 318 432 565 715 882 1068 1271

110 0.1 0.6 2.3 5.1 9.0 14.1 20.3 27.6 36.1 58 81 144 226 325 442 578 731 903 1092 1300

1 psi = 27.68" H 2O discharge coeffecient = 0.65 Air Temperature = 70 deg F Airflow in CFM

VacuumOrifice Diameters - Inches

Vacuum " Hg 1/32 1/16 1/8 3/16 1/4 5/16 3/8 7/16 1/2 5/8 3/4 1 1-1/4 1-1/2 1-3/4 2.0 2-1/4 2-1/2 2-3/4 3

0.5 0.0 0.1 0.6 1.3 2.2 3.5 5.1 6.9 9 14 20 36 56 81 110 144 182 225 272 324

1 0.0 0.2 0.8 1.8 3.1 4.9 7.1 9.6 13 20 28 50 79 113 154 202 255 315 381 453

2 0.1 0.3 1.1 2.5 4.4 6.8 9.8 13.0 17 27 39 70 109 157 214 280 354 437 529 629

3 0.1 0.3 1.3 3.0 5.2 8.2 11.8 16.0 21 33 47 84 131 189 257 336 425 525 635 756

4 0.1 0.4 1.5 3.3 5.9 9.3 13.4 18.0 24 37 53 95 148 214 291 380 481 594 718 855

5 0.1 0.4 1.6 3.7 6.5 10.0 14.6 20.0 26 41 58 104 162 234 318 416 526 650 786 936

6 0.1 0.4 1.7 3.9 7.0 11.0 15.7 21.0 28 44 63 111 174 251 341 446 564 696 842 1002

7 0.1 0.5 1.8 4.1 7.3 11.0 16.5 22.0 29 46 66 118 184 264 360 470 595 735 889 1058

8 0.1 0.5 1.9 4.3 7.7 12.0 17.3 23.0 31 48 69 123 192 276 376 491 621 766 927 1104

9 0.1 0.5 2.0 4.5 7.9 12.0 17.8 24.0 32 50 71 127 198 285 388 507 642 792 959 1141

10 0.1 0.5 2.0 4.6 8.1 13.0 18.3 25.0 33 51 73 130 203 293 398 520 659 813 984 1171

11 0.1 0.5 2.1 4.7 8.3 13.0 18.7 25.0 33 52 76 133 207 298 406 530 671 829 1003 1193

12 0.1 0.5 2.1 4.7 8.4 13.0 18.9 26.0 34 52 76 134 210 302 412 538 680 840 1016 1210

13 0.1 0.5 2.1 4.8 8.5 13.0 19.1 26.0 34 53 76 135 212 305 415 542 686 847 1025 1219

14 0.1 0.5 2.1 4.8 8.5 13.0 19.1 26.0 34 53 76 136 212 306 416 544 688 849 1028 1223

15 0.1 0.5 2.1 4.8 8.5 13.0 19.1 26.0 34 53 76 136 212 306 416 544 688 849 1028 1223

1" HG = 13.6" H2O discharge coeffecient = 0.65 Air Temperature = 70 deg F Airflow in CFM

Airflow Through an OrificeTECHNICAL

1-1/4 1-1/2 1-3/4 2.0 2-1/4 2-1/2 2-3/4 3

88