1
FFL 60.380m Level 0 (Ground Floor) Good quality stock brick external skin TBS. Maranello or similar quality Tecu or Falzinc Roof cladding to pitches of main roof External shading elements formed of perforated and coated metal Glulam frame elements forming loggia and framing external shading elements Schuco or similar aluminium double glazed windows Schuco or similar curtain walling to therapy areas FFL 63.080m Ceiling - GF FFL 63.780m Level 1 (First Floor) FFL 60.380m Level 0 (Ground Floor) Good quality stock brick external skin TBS. Maranello or similar quality Schuco or similar aluminium double glazed windows Schuco or similar curtain walling to therapy areas External shading elements formed of perforated and coated metal Glulam frame elements forming loggia and framing external shading elements Tecu or Falzinc Roof cladding to pitches of main roof FFL 63.080m Ceiling - GF FFL 63.780m Level 1 (First Floor) Possible future link STATUS Danks Warehouse Diglis Basin 60 Diglis Road Worcester WR5 3BW tel 01905 358626 PROJECT AND DRAWING NO. CLIENT Macmillan Cwm Taf University Health Board Date By Description Rev Date By Description Rev SCALE SIZE A1 A1 A1 A1 DRAWING PROJECT Planning Planning Planning Planning 0662/ 0662/ 0662/ 0662/ DR-114 DR-114 DR-114 DR-114 (C) (C) (C) (C) Proposed Elevations 1/2 Proposed Elevations 1/2 Proposed Elevations 1/2 Proposed Elevations 1/2 Y Bwthyn Macmillan Specialist Care Unit Y Bwthyn Macmillan Specialist Care Unit Y Bwthyn Macmillan Specialist Care Unit Y Bwthyn Macmillan Specialist Care Unit 1:100 1:100 1:100 1:100 South Elevation South Elevation South Elevation South Elevation West Elevation West Elevation West Elevation West Elevation A Elevations updated to latest design HW 31.10.16 B Updated to reflect changes to roof deign. Glazing reduced and opening lights indicated. HW 20.01.17 C Minor amendments following design development HW 07.03.17

Kkeserver2016Share2016KKE Projects Folder01. LIVE ... Bwthyn...to pitches of main roof FFL 63.080m Ceiling - GF FFL 63.780m Level 1 (First Floor) Possible future link STATUS Danks

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Kkeserver2016Share2016KKE Projects Folder01. LIVE ... Bwthyn...to pitches of main roof FFL 63.080m Ceiling - GF FFL 63.780m Level 1 (First Floor) Possible future link STATUS Danks

FFL 60.380m

Level 0 (Ground Floor)

Good quality stock brick external skin TBS.Maranello or similar quality

Tecu or Falzinc Roof cladding to pitches of main roof

External shading elements formed of perforated and coated metal

Glulam frame elements forming loggia and framing external shading elements

Schuco or similar aluminium double glazed windows

Schuco or similar curtain walling to therapy areas

FFL 63.080m

Ceiling - GF

FFL 63.780m

Level 1 (First Floor)

FFL 60.380m

Level 0 (Ground Floor)

Good quality stock brick external skin TBS.Maranello or similar quality

Schuco or similar aluminium double glazed windows Schuco or similar curtain walling to

therapy areas

External shading elements formed of perforated and coated metal

Glulam frame elements forming loggia and framing external shading elements

Tecu or Falzinc Roof cladding to pitches of main roof

FFL 63.080m

Ceiling - GF

FFL 63.780m

Level 1 (First Floor)

Possible future link

STATUS

Danks WarehouseDiglis Basin

60 Diglis RoadWorcesterWR5 3BW

tel 01905 358626

PROJECT AND DRAWING NO.

CLIENT

Macmillan Cwm Taf UniversityHealth Board

DateByDescriptionRevDateByDescriptionRevSCALE SIZE

A1A1A1A1

DRAWINGPROJECT

PlanningPlanningPlanningPlanning0662/0662/0662/0662/ DR-114DR-114DR-114DR-114 (C)(C)(C)(C)

Proposed Elevations 1/2Proposed Elevations 1/2Proposed Elevations 1/2Proposed Elevations 1/2Y Bwthyn Macmillan Specialist Care UnitY Bwthyn Macmillan Specialist Care UnitY Bwthyn Macmillan Specialist Care UnitY Bwthyn Macmillan Specialist Care Unit 1:1001:1001:1001:100

South ElevationSouth ElevationSouth ElevationSouth Elevation

West ElevationWest ElevationWest ElevationWest Elevation

A Elevations updated to latest design HW 31.10.16

B Updated to reflect changes to roof deign. Glazing reduced and opening lights indicated.

HW 20.01.17

C Minor amendments following design development HW 07.03.17