Abstract
This is a study of using Aspen HYSIS to design a separation process o
ammonia and water. In this study, it is to understand the usage of condenser,
valve and separation process. Information from the given manual as a guide are
used in the HYSIS program.
1.0PROCEDURE
Methodology for process separation of ammonia and water using Aspen HYSIS:
1. First, the Aspen HYSIS user interface is opened and Aspen HYSIS blank
simulation is chosen.
2. Condenser, separator, and valve models are dragged one by one from the
unit operation model pallet onto the flow sheet.
3. All streams from each unit operation models are connected. Each stream
and model block is renamed.
4. Setup, components, properties, streams, and blocks inputs from data
browser are filled with related information and values.
5. ‘Next’ button is pressed as for running the simulation process.
2.0PROCESS FLOW DIAGRAM (PFD)
Figure 1: Process flow diagram of ammonia and water through a separator.
3.0WORKBOOK
Stream Name Feed 1 3 4Vapor/ Phase Fraction 1.0000 1.0000 1.0000 0.0000Temperature [C] 143.6 143.6 131.6 131.6Pressure [bar] 17.42 17.42 6.900 6.900Molar Flow [kgmole/h] 4536 4536 4536 0.0000Mass Flow [kg/h] 7.810e+004 7.810e+004 7.810e+004 0.0000Std Ideal Liq Vol Flow [m3/h]
117.1 117.1 117.1 0.0000
Molar Enthalpy [kJ/kgmole]
-7.962e+004 -7.962e+004 -7.962e+004 -2.352e+005
Molar Entropy [[kJ/kgmole.C]
162.7 162.7 169.9 84.32
Heat Flow [kJ/h] -3.611e+008 -3.611e+008 -3.611e+008 -0.0000Liq Vol Flow @ Std Con [m3/h]
115.7 115.7 115.7 0.0000
Master Comp Mole Frac (Ammonia)
0.8088 0.2020
Master Comp Mole Frac (Water)
0.1912 0.7980
Figure 2: Parameters computed for each streams.
4.0QUESTIONS AND DISCUSSIONS
1. What is the temperature of the outlet stream of the condenser?
According to Figure 1, the outlet stream temperature of condenser, from E-100 to VLV-100 is 143.6˚C.
2. What are the mole fractions for ammonia and water in the vapor and liquid stream of the separator?
Mole fractions for ammonia and water in the vapor stream of the separator are:-Ammonia = 0.8088Water = 0.1912
Mole fractions for ammonia and water in the liquid stream of the separator are:-Ammonia = 0.2020Water = 0.7980
3. Determine the mass flow rate for each outlet stream of the separator.
Mass flow rate of vapor stream = 78100 kg/hMass flow rate of liquid stream = 0.0000 kg/h
All the values inserted in the Aspen HYSIS according to the manual provided output
the results as show in the Figure 2. It is known that the condenser is used to release
heat from the heater E-100 and maintaining the temperature opted. The valve VLV-100
channels the stream to the separator, and separation process occurs at the separator.
Ammonia and water are separated into vapor and liquid streams. The produced values
are assumed accurate using Advanced Peng-Robinson property package.