2
LAVI | Versatile as Life itself Intuitive | Individual | Compact HOFFRICHTER LAVI 30 HOFFRICHTER LAVI 40 36631 / Version 2017-06-19 Order Information Description Order No. HOFFRICHTER LAVI 30 HomeCare ventilation device with exhalation valve 36490 HOFFRICHTER LAVI 40 HomeCare ventilation device with exhalation valve 36491 CPAP tube 180 cm (reusable) 22 ID, without pressure measurement 23217 CPAP tube 180 cm (single-use) 22 ID, without pressure measurement 30190 HOFFRICHTER Comfort tube system Heatable tube system 31141 Philips Whisper Swivel II exhalation valve 36527 Iso-Gard filter bacterial/ viral filter 26394 HOFFRICHTER LAVI 40 replacement battery RRC2054 36531 HOFFRICHTER LAVI 40 battery charger 36532 HOFFRICHTER BATTERY PACK uni BASE (ventilation) 29377 HOFFRICHTER BATTERY PACK uni PLUS for uni BASE 30781 HOFFRICHTER GmbH Mettenheimer Str. 12/14 | D-19061 Schwerin Tel. +49 (0)385 39925-0 [email protected] | www.hoffrichter.de Ventilation parameters Parameter PCV APCV PSV PSV-S P-SIMV 1 CPAP Pressure 4 – 20 hPa IPAP HOFFRICHTER LAVI 30: 4 – 30 hPa, LAVI 40: 4 – 40 hPa PS HOFFRICHTER LAVI 30: 4 – 30 hPa, LAVI 40: 4 – 40 hPa PEEP 0 – 20 hPa [PEEP ≤ IPAP-3 hPa] Frequency 4 – 50 bpm Apnoea Time 0 – 60 s Time Inspiration 0,3 – 8 s I:E 4,00 : 1 – 1 : 4,00 Ti Max 1 – 10 s Ti Min Off, 0,4 – 5 s Ramp Level 1 – 5 Inspiration Ttrigger Level 1 – 10, auto Exspiration Trigger 10 – 90 % Trigger Lock Off, 0.5 – 4 s [≤ 80 % of max. expiration time] Minimum Volume 1 Off, 0,05 – 2 l [HOFFRICHTER LAVI 40: if IPAP > 37 hPa, then always off] Additional pressure 1 3 – 10 hPa [HOFFRICHTER LAVI 40: Additional pressure ≤ 40 hPa – IPAP] Sigh Function On, Off Technical data Dimensions (W x D x H) 215 x 203 x 115 mm Weight 2,2 kg Mains operation 100…240 V AC (-20 %, 10 %), 50...60 Hz, 24 V DC / 3,75 Ah Internal battery operation Lithium-ion battery, 15 V (nominal voltage) / 3.2 Ah, Max. inspiratory working pressure HOFFRICHTER LAVI 30: 30 hPa, HOFFRICHTER LAVI 40: 40 hPa External battery operation HOFFRICHTER AKKUPACK uni BASE/PLUS, 20...26 V (nominal voltage) / 5 A Maximum power consumption 75 W, Max. flow at 40 hPa with humidifilter 1 : 175 l/min, without humidifilter: 220 l/min 1 only in HOFFRICHTER AquaTREND uni Alarm parameters Apnoea Alarm / High Frequency / Low Frequency / High Inspiration Volume / Min. Inspiration Volume / High Minute Ventilation / Low Minute Ventilation / Leak Rate / Low FiO 2 / High FiO 2 / High Pressure Tolerance / Low Pressure Tolerance Scope of Supply HOFFRICHTER LAVI , charger, mains lead, therapy tube, filter cardridge, SD-card, carry case 1 only in HOFFRICHTER LAVI 40

LAVI | Versatile as Life itself - Servonahoffrichter.servona.de/wp-content/uploads/2017/09/36631-_PI_HOFF... · LAVI | Versatile as Life itself Intuitive | Individual | Compact –

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: LAVI | Versatile as Life itself - Servonahoffrichter.servona.de/wp-content/uploads/2017/09/36631-_PI_HOFF... · LAVI | Versatile as Life itself Intuitive | Individual | Compact –

LAVI | Versatile as Life itselfIntuitive | Individual | Compact

– HOFFRICHTER LAVI 30– HOFFRICHTER LAVI 40

3663

1 / V

ersio

n 20

17-0

6-19

Order InformationDescription Order No.

HOFFRICHTER LAVI 30 HomeCare ventilation device with exhalation valve 36490

HOFFRICHTER LAVI 40 HomeCare ventilation device with exhalation valve 36491

CPAP tube 180 cm (reusable) 22 ID, without pressure measurement 23217

CPAP tube 180 cm (single-use) 22 ID, without pressure measurement 30190

HOFFRICHTER Comfort tube system Heatable tube system 31141

Philips Whisper Swivel II exhalation valve 36527

Iso-Gard filter bacterial/ viral filter 26394

HOFFRICHTER LAVI 40 replacement battery RRC2054 36531

HOFFRICHTER LAVI 40 battery charger 36532

HOFFRICHTER bATTERy PACK uni bASE (ventilation) 29377

HOFFRICHTER bATTERy PACK uni PLUS for uni bASE 30781

HOFFRICHTER GmbHMettenheimer Str. 12/14 | D-19061 Schwerin Tel. +49 (0)385 [email protected] | www.hoffrichter.de

Ventilation parametersParameter PCV APCV PSV PSV-S P-SIMV1 CPAP

Pressure 4 – 20 hPa •IPAP HOFFRICHTER LAVI 30: 4 – 30 hPa, LAVI 40: 4 – 40 hPa • • • • •PS HOFFRICHTER LAVI 30: 4 – 30 hPa, LAVI 40: 4 – 40 hPa •PEEP 0 – 20 hPa [PEEP ≤ IPAP-3 hPa] • • • • •Frequency 4 – 50 bpm • • • •Apnoea Time 0 – 60 s •Time Inspiration 0,3 – 8 s • • • •I:E 4,00 : 1 – 1 : 4,00 • • • •Ti Max 1 – 10 s • • •Ti Min Off, 0,4 – 5 s • • •Ramp Level 1 – 5 • • • • •Inspiration Ttrigger Level 1 – 10, auto • • • •Exspiration Trigger 10 – 90 % • • •Trigger Lock Off, 0.5 – 4 s

[≤ 80 % of max. expiration time]• • • •

Minimum Volume1 Off, 0,05 – 2 l[HOFFRICHTER LAVI 40: if IPAP > 37 hPa, then always off]

• • • •

Additional pressure1 3 – 10 hPa[HOFFRICHTER LAVI 40: Additional pressure ≤ 40 hPa – IPAP]

• • • •

Sigh Function On, Off • • • • •

Technical dataDimensions (W x D x H) 215 x 203 x 115 mm

Weight 2,2 kg

Mains operation 100…240 V AC (-20 %, 10 %), 50...60 Hz, 24 V DC / 3,75 Ah

Internal battery operationLithium-ion battery, 15 V (nominal voltage) / 3.2 Ah, Max. inspiratory working pressure HOFFRICHTER LAVI 30: 30 hPa, HOFFRICHTER LAVI 40: 40 hPa

External battery operation HOFFRICHTER AKKUPACK uni bASE/PLUS, 20...26 V (nominal voltage) / 5 A

Maximum power consumption 75 W, Max. flow at 40 hPa with humidifilter1: 175 l/min, without humidifilter: 220 l/min

1 only in HOFFRICHTER AquaTREND uni

Alarm parameters Apnoea Alarm / High Frequency / Low Frequency / High Inspiration Volume / Min. Inspiration Volume / High Minute Ventilation / Low Minute Ventilation / Leak Rate / Low FiO2 / High FiO2 / High Pressure Tolerance / Low Pressure Tolerance

Scope of Supply

HOFFRICHTER LAVI, charger, mains lead, therapy tube, filter cardridge, SD-card, carry case

1 only in HOFFRICHTER LAVI 40

Page 2: LAVI | Versatile as Life itself - Servonahoffrichter.servona.de/wp-content/uploads/2017/09/36631-_PI_HOFF... · LAVI | Versatile as Life itself Intuitive | Individual | Compact –

Ventilation LAVI

HOFFRICHTER LAVI – designed for the intermittent pressure-controlled ventilation of patients and

intended for both invasive and non-invasive ventilation therapy. The device is suitable for adults and

children with the tidal volume of 100 ml and more; it can be used in a hospital or home environment.

Ventilation Modes:

HOFFRICHTER LAVI 30: PCV / APCV / PSV / PSV-S / CPAP

HOFFRICHTER LAVI 40: PCV / APCV / PSV / PSV-S / P-SIMV / CPAP

LAVI | Versatile as Life itselfIntuitive | Individual | Compact

Made in Germany

HOFFRICHTER LAVI has been developed by highly-qualified engineers from the

HOFFRICHTER company based on the latest research. The ventilator is assembled

in Germany in compliance with the strictest quality standards – also in Germany.

More than whisper quiet

HOFFRICHTER Silence Technology stands for whisper-quiet operation of the high-

power turbine even at its maximum operation performance. Continuous non-distur-

bing treatment is thus possible even during the night. Precise flow and pressure

triggers react quickly to patient requirements, thus permitting the ideal adjustment

and fast synchronisation.

Light and compact

The HOFFRICHTER LAVI is not only elegant in design, but also extremely compact with

its weight of only 2.2 kg. The optional functional bag makes it possible to mount the

device to a wheelchair, protecting it against any weather conditions while in use.

Independent – thanks to rechargeable batteries

The internal battery with up to 4h operation time is easy to replace. In combination

with our bATTERy PACK, up to 20 hours of autonomy are thus possible.

Real-time monitoring

Each menu level displays the most relevant measured values. It is easy to choose only

the needed values to be shown in each display box.

Simple and intelligent handling

HOFFRICHTER LAVI stands out for its simple and intelligent handling. The flat menu

structure, in particular, makes it easy to call up the desired function. Navigation within

the menu is done with the help of the multi-function button and the three soft keys.

The menu structure is identical to that of the HOFFRICHTER Carat pro, thus reducing

the training need for users.