42
2011/7/4 1 IEC/EN 61347-2-13 LED Driver IEC/EN 61347-2-13 的驗證要求說明 .

LED Driver IEC/EN 61347-2-13 LED Driver IEC/EN 61347-2-13 ...u.dianyuan.com/upload/space/2011/11/02/1320195077-553196.pdf · IEC/EN 61347-2-13 Test Items: - Fault condition test (component

  • Upload
    others

  • View
    19

  • Download
    0

Embed Size (px)

Citation preview

  • 2011/7/4 1

    IEC/EN 61347-2-13

    LED Driver IEC/EN 61347-2-13 的驗證要求說明LED Driver IEC/EN 61347-2-13 的驗證要求說明

    .

  • 2011/7/4 2

    IEC/EN 61347-2-13

    本課程主要內容

    IEC/EN 61347 標準介紹

    名詞定義

    標示

    零件要求

    結構要求

    測試項目

  • 2011/7/4 3

    IEC/EN 61347-2-13

    IEC/EN 61347 系列標準介紹

    一般要求: IEC 61347-1:2007, EN 61347-1:2008Lamp controlgear-Part 1: General and safety requirements

    常用的 Part 2 個別要求 (Particular requirements)

    IEC/EN 61347-2-1: for starting devices other than glow starter (Ignitor, Electronic starter) --- 點火器

    IEC/EN 61347-2-2: for d.c. or a.c. supplied electronic step-down convertors forfilament lamps) --- 電子式變壓器

    IEC/EN 61347-2-3: for a.c. supplied electronic ballasts for fluorescent lamps --- 電子式安定器

  • 2011/7/4 4

    IEC/EN 61347-2-13

    常用的 Part 2 個別要求 (Particular requirements)

    IEC/EN 61347-2-8: for ballast for fluorescent lamps (Winding type ballast) --- 線圈式安定器

    IEC/EN 61347-2-9: Particular requirements for ballast for discharge lamp excluding fluorescent lamps (Winding type ballast) --- HID 安定器

    IEC/EN 61347-2-10: for electronic invertors and convertor for high-frequencyoperation

    IEC/EN 61347-2-11: for miscellaneous electronic circuits used with luminaires

    IEC/EN 61347-2-12: for Electronic ballast for discharge lamp (HID Ballast) --- HID 電子式安定器

    IEC/EN 61347-2-13: for d.c. or a.c. supplied electronic controlgear for LED modules --- 照明用LED 電源供應器

  • 2011/7/4 5

    IEC/EN 61347-2-13

    IEC 61347-1: 2007EN 61347-1: 2008Lamp controlgear-General and safety requirements

    IEC 61347-2-13: 2006EN 61347-2-13: 2006Particular requirements for d.c. or a.c. suppliedelectronic controlgear for LED modules

  • 2011/7/4 6

    IEC/EN 61347-2-13

    IEC/EN 61347-2-13 的應用範圍

    電源輸入:

    ≤ 250 Vdc 或≤ 1000 Vac, 50Hz or 60Hz

    輸出電壓:

    SELVSELV equivalent (等效SELV)Higher voltages

  • 2011/7/4 7

    IEC/EN 61347-2-13

    名詞定義

  • 2011/7/4 8

    IEC/EN 61347-2-13

    名詞定義

  • 2011/7/4 9

    IEC/EN 61347-2-13

    Built in controlgear ?(內置於燈具, 線盒, 外殼內)

    Independent SELV controlgear ?(可裝置於燈具外無須額外之外殼, 且具有其標示所示之保護功能)

    Additional compliance of Annex I

    符合 IEC 60598-1 相關要求

  • 2011/7/4 10

    IEC/EN 61347-2-13

    Built in type or Independent type ?

  • 2011/7/4 11

    IEC/EN 61347-2-13

    Marking:

    必須標示

    依產品狀況而定

    50/60Hz

  • 2011/7/4 12

    IEC/EN 61347-2-13

    Marking:

    其它標示要求如下:

    可更換零件的清楚說明

    接地符號

    定電壓輸出形式的產品: 額定輸出電壓 (V)

    定電流輸出形式的產品: 額定輸出電流 (A), 額定最大輸出電壓 (V)

    The controlgear is suitable for operation with LED modules only.

    (只供 LED 模組使用)

  • 2011/7/4 13

    IEC/EN 61347-2-13

    Marking or manufacturer’s catalogue or similar:

  • 2011/7/4 14

    IEC/EN 61347-2-13

  • 2011/7/4 15

    IEC/EN 61347-2-13

    Fail-safe controlgear不正確使用下功能失效,無危險性

    Non-short-circuit proof controlgear 無短路保護

    Short-circuit proof controlgear具短路保護

    Inherently short-circuit proof controlgear 保護元件失效下, 過載或短路時溫度不會超過限制值,過載或短路移除後產品可恢復正常運作

    Non-inherently short-citcuitproof controlgear 過載或短路時,保護元件動作

  • 2011/7/4 16

    IEC/EN 61347-2-13

    必須符合 DIN VDE 0710-14

    組裝說明書或使用手冊, 必須標示產品使用時的周圍環境,

    範例圖示如下:

    ? mm

    ? mm

    ? mm ? mm

  • 2011/7/4 17

    IEC/EN 61347-2-13

    不正常運作下, 外殼最高溫度 ≤ 130°C

    不正常運作下, 外殼最高溫度 ≤ 110°C

    正常運作下, 外殼最高溫度 ≤ 95°C

    不正常運作下, 外殼最高溫度 ≤ 115°C

    tc 正常運作下, 外殼最高溫度 ≤ tc°C

  • 2011/7/4 18

    IEC/EN 61347-2-13

    Components:

    重要零件需提供歐規TUV或VDE(IEC/EN)證書

    電流保險絲必須為歐規認可品

    Independent controlgear 的電源線絕緣材質必須為歐規認可品, 且電源

    線線徑必須至少 0.75 mm2

    若產品定義防水防塵 (IP code) (IPX1 or higher),

    則 independent controlgear 的電源線絕緣材質必須是橡膠

    (rubber, H05RN-F), 且線徑必須至少 1.0 mm2

  • 2011/7/4 19

    IEC/EN 61347-2-13

    Construction: Built in SELV controlgear:

    Primary Secondary

    Earth

    L

    N

    Cl. 1.7mmCr. 2.5mm

    B: Cl. 2.0mmB: Cr. 2.5mm

    R: Cl. 4.0mmR: Cr. 5.0mm

    R: Reinforced insulation

    B: Basic insulation

    Between fuse terminations: Cr. 2.5mm, Cl. 1.7mm

    變壓器絕緣距離 依工作電壓查表 (IEC60065, Tables 8-11)

    Supposed Input 250Vac

    ?

  • 2011/7/4 20

    IEC/EN 61347-2-13

    Construction: Independent SELV controlgear:

    Primary Secondary

    Earth

    L

    N

    Cl. 3.0mmCr. 3.0mm

    B: Cl. 3.0mmB: Cr. 3.0mm

    R: Cl. 6.0mmR: Cr. 6.0mm

    R: Reinforced insulation

    B: Basic insulation

    S: Supplementary insulation

    S: Cl./ Cr. 依工作電壓查表

    Between fuse terminations: Cr. 3.0mm, Cl. 3.0mm

    變壓器絕緣距離 依工作電壓查表 (IEC 61347-2-13, Table I.7)

    Earthed enclosure

    Supposed Input 250Vac

    no connection

  • 2011/7/4 21

    IEC/EN 61347-2-13

    Construction: Independent SELV controlgear:

    Primary Secondary

    R: Reinforced insulation

    Plastic Enclosure

    R: Cl. 6.0mmR: Cr. 6.0mm

    R: Cl. 6.0mmR: Cr. 6.0mm

    R: Cl./ Cr. 依工作電壓查表

    Supposed Input 250Vac

    user accessible part

  • 2011/7/4 22

    IEC/EN 61347-2-13

    Construction: Independent SELV controlgear:

    Distance through insulation (R) - three layers of thin sheet insulation: 0.3mm (output > 100VA)

    0.2mm (output: 25VA ∼ 100VA) 0.1mm (output: < 25VA)

    S

    P

    P

  • 2011/7/4 23

    IEC/EN 61347-2-13

    Construction: Independent SELV controlgear:

    Distance through insulation (R): 1.0mmInput terminals output terminals: ≥ 25 mm

  • 2011/7/4 24

    IEC/EN 61347-2-13

    Construction: Screw Terminal clause 14 of IEC 60598-1

    ‧線材的線徑必須能完全插入terminal,且必須完全被夾住

    ‧線材在螺絲鎖完後不能鬆落

    ‧線材線徑大小必須符合規範要求

    常見的 screw terminal

  • 2011/7/4 25

    IEC/EN 61347-2-13

    Construction: Screwless Terminal clause 15 of IEC 60598-1

    常見的 screwless terminal

  • 2011/7/4 26

    IEC/EN 61347-2-13

    Test Items: - Discharge test (1 min., ≤ 50V)- Protection of contact with live part: 10N force- Output exposed terminals test (for SELV-or SELV

    equivalent controlgear)< 25 Vrms under load < 33 Vrms or 33√2 Vpeak under no-load

    - Grounding test25A/1min. < 0.5 Ω

    - Humidity test 91-95%, 20-30°C, 48h

  • 2011/7/4 27

    IEC/EN 61347-2-13

    Test Items: - Insulation resistance test (immediately after humidity)

    500V, 1min. B: > 2MΩ, D/R: > 4MΩ- Electric strength test Output circuit metal enclosure ?

  • 2011/7/4 28

    IEC/EN 61347-2-13

    Supplementary information:

  • 2011/7/4 29

    IEC/EN 61347-2-13

    Test Items: Transformer Heating test

    Normal operation: comply IEC 60065 Table 3Abnormal operation: comply IEC 60065 Table 3

  • 2011/7/4 30

    IEC/EN 61347-2-13

    Test Items: Heating test

    Enclosure for testing: Annex F

    Annex D

    Note: Temp. shall be measured under ta.

  • 2011/7/4 31

    IEC/EN 61347-2-13

    Test Items: - Fault condition test (component failure)

    (temp. shall be measured under enclosure temp. tc)- Abnormal test (test for 1 hour)

    I/P: -10%/+10% of supply voltageLength of cable for testing: 20cm and 200cmFor constant voltage output type* No LED module inserted* Double the LED module load (two LEDs connected in parallel)* Output shorted (multiple output, each output short-circuite in turn)

    (temp. shall be measured under enclosure temp. tc)

  • 2011/7/4 32

    IEC/EN 61347-2-13

    Test Items: - For constant current output type

    * No LED module inserted* Double the LED module load (two LEDs connected in series)* Output shorted

    (multiple output, each output short-circuite in turn)

    (temp. shall be measured under enclosure temp. tc)

  • 2011/7/4 33

    IEC/EN 61347-2-13

    Test Items: - Power cord pull test:

    60N, 0.15Nm displacement < 2.0mm

    - Torque test for screw terminal 測試次數: 5 次測試力距: 依照 IEC 60598-1 Table 14.4 或 Figures 12-16 中適用螺絲的力距, 以較大的力距測試

  • 2011/7/4 34

    IEC/EN 61347-2-13

    Test Items: - Live part measurement

    I/P: rated voltage* Measured according to IEC60990 circuit (measured point: part concerned earth)

    * non-inductive resistance 50kΩ, >34Vpeak is live part (measured point: part concerned accessible part)

    U2/500 mA

    Note: one pole of the test supply shall be at earth potential.

  • 2011/7/4 35

    IEC/EN 61347-2-13

    Test Items: - Ball pressure test

    * 125°C for parts retaining live parts in position* 75°C for other parts providing protection against

    electric shock

    - Glow-wire test650°C, 30s for external parts of insulating material

    - Needle-frame test10s for insulating material retaining live parts in position

  • 2011/7/4 36

    IEC/EN 61347-2-13

    Supplementary information:

  • 2011/7/4 37

    IEC/EN 61347-2-13

    Test Items: For Independent SELV controlgear- Heating test (comply Table I.1)

  • 2011/7/4 38

    IEC/EN 61347-2-13

    Test Items: For Independent SELV controlgear- Short-circuit and overload protection (comply Table I.3)

  • 2011/7/4 39

    IEC/EN 61347-2-13

    Test Items: For Independent SELV controlgear- Insulation resistance test (according to Table I.5)

  • 2011/7/4 40

    IEC/EN 61347-2-13

    Test Items: For Independent SELV controlgear- Electric strength test (according to Table I.6)

  • 2011/7/4 41

    IEC/EN 61347-2-13

    判定標準: 外殼不可破裂, 導致無法符合

    EN 60598其他章節之求. (例如: 帶電體可被測試手指碰觸, 防水防塵等級無法

    維持等)

    Test Items: For Independent SELV controlgear- Mechanical strength test (EN 60598-1 Table 4.3)

  • 2011/7/4 42

    IEC/EN 61347-2-13

    Questions ?