LED Tubes for CLINICAL OBSERVATION CARINDA INTERNATIONAL PTY LTD 32/10 Gladstone Rd, Castle Hill, NSW 2154 Ph: (02) 9894 9800 Fax: (02) 9634 2708 Email: [email protected] Due to rapidly advancing technology, Carinda’s LED range is under continuous development and product improvement. Carinda reserves the right to change or alter any information and/or specifications without notice. Installation should be undertaken by a licenced electrician and in strict accordance with the instructions provided to ensure safety and for warranty compliance. www.carinda.com.au Carinda International’s new “True White” LED tubes are engineered to meet the stringent colour requirements for illumination of Clinical Observation areas within Hospitals, Clinics, Healthcare and all other Medical facilities. “True White” is compliant with Australian Standard AS/NZS 1680.2.5 for Cyanosis Observation (COI). State of the art LED and driver technologies produce exceptional lighting performance and power savings of around 55% compared to existing “Cyanosis” type fluorescent tubes. Carinda’s Clinical Observation range utilises specially engineered “True White” LED chips with exceptionally high Colour Rendering (CRI). Using all white chips produces significantly higher efficiency than other LED products that must include additional red LEDs to compensate for the poor CRI and COI performance of their inferior white LEDs. ENGINEERED FOR MAXIMUM INHERENT SAFETY: Shatterproof polycarbonate diffuser & end caps. Fully insulated, with no safety risk from exposed metal parts as used in other LED tube products. Internally fused, surge protected and supplied with a fused starter replacement. Diffuser, End Caps and PCB manufactured from UL94 Listed Class V-0 Self-Extinguishing materials. NATA tested and certified compliant with the new LED safety standard AS/NZS 60598.2.1:2014. Certificate of Suitability from NSW Fair Trading. TESTING and COMPLIANCE (NATA Registered Laboratory) Criteria Test Standard(s) Result Electrical Safety AS/NZS 60598.2.1:2014 AS/NZS 61347.2.13:2013 Complies Photobiological Safety AS/NZS IEC 62471:2011 Group 0 (No risk) Colour Rendering Index (CRI) IES LM-79-08 91.5 Cyanosis Observer Index (COI) AS/NZS 1680.2.5:1997 2.5 GENERAL SPECIFICATIONS Replaces: T8 (26mm) Fluorescent (G13 lamp caps) Diffuser: Frosted Polycarbonate (165° beam angle) Rotating End Caps: 180° (+/- 90°) with locking latch Efficacy (incl driver): 115 Lumens per Watt (4 foot frosted) Colour Temperature: 4000 K (nominal) (3300K to 5300K to order) Rated Lamp Life: >35,000 hours (L70 LM-80/TM-21) ORDERING CODES Clinical Observation 4000K Frosted Model Number Nom. Length Power (LCP) Rated Output CIT-06-08W-FR40-CO 2 foot 7.22 W 950 lm CIT-12-17W-FR40-CO 4 foot 16.82 W 2000 lm CIT-15-23W-FR40-CO 5 foot 22.34 W 2675 lm CYANOSIS OBSERVATION Compliant with Australian Standard AS/NZS 1680.2.5:1997 Technical Data VEET APPROVED PRODUCT Energy savings scheme compliant The CIT “Clinical Observation” models share most features with the wide range of Carinda ‘CIT Series’ LED Tubes. The Light Output, Colour, CRI and Power of each product range are tailored to suit specific project specifications. Please refer to the other CIT Series Data Sheets for full details ZERO IR+UV NOTE: This model range can also be manufactured in high output versions SPECTRAL ENERGY DISTRIBUTION POLAR CURVE Rev 1.1c – 28/05/15

LED Tubes for CLINICAL OBSERVATION Technical …LED Tubes for CLINICAL OBSERVATION CARINDA INTERNATIONAL PTY LTD 32/10 Gladstone Rd, Castle Hill, NSW 2154 Ph: (02) 9894 9800 Fax: (02)

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: LED Tubes for CLINICAL OBSERVATION Technical …LED Tubes for CLINICAL OBSERVATION CARINDA INTERNATIONAL PTY LTD 32/10 Gladstone Rd, Castle Hill, NSW 2154 Ph: (02) 9894 9800 Fax: (02)

LED Tubes for CLINICAL OBSERVATION

CARINDA INTERNATIONAL PTY LTD 32/10 Gladstone Rd, Castle Hill, NSW 2154 Ph: (02) 9894 9800 Fax: (02) 9634 2708

Email: [email protected]

Due to rapidly advancing technology, Carinda’s LED range is under continuous development and product improvement. Carinda reserves the right to change or alter any information and/or specifications without notice. Installation should be undertaken by a licenced electrician and in strict accordance with the instructions provided to ensure safety and for warranty compliance.

www.carinda.com.au

Carinda International’s

new “True White” LED tubes

are engineered to meet the stringent

colour requirements for illumination of Clinical

Observation areas within Hospitals, Clinics, Healthcare

and all other Medical facilities.

“True White” is compliant with Australian Standard

AS/NZS 1680.2.5 for Cyanosis Observation (COI). State of

the art LED and driver technologies produce exceptional

lighting performance and power savings of around 55%

compared to existing “Cyanosis” type fluorescent tubes.

Carinda’s Clinical Observation range utilises specially

engineered “True White” LED chips with exceptionally high

Colour Rendering (CRI). Using all white chips produces

significantly higher efficiency than other LED products that

must include additional red LEDs to compensate for the

poor CRI and COI performance of their inferior white LEDs.

ENGINEERED FOR MAXIMUM INHERENT SAFETY:

Shatterproof polycarbonate diffuser & end caps.

Fully insulated, with no safety risk from exposed metal parts as used in other LED tube products.

Internally fused, surge protected and supplied with a fused starter replacement.

Diffuser, End Caps and PCB manufactured from UL94 Listed Class V-0 Self-Extinguishing materials.

NATA tested and certified compliant with the new LED safety standard AS/NZS 60598.2.1:2014.

Certificate of Suitability from NSW Fair Trading.

TESTING and COMPLIANCE (NATA Registered Laboratory)

Criteria Test Standard(s) Result

Electrical Safety AS/NZS 60598.2.1:2014 AS/NZS 61347.2.13:2013

Complies

Photobiological Safety AS/NZS IEC 62471:2011 Group 0 (No risk)

Colour Rendering Index (CRI) IES LM-79-08 91.5

Cyanosis Observer Index (COI) AS/NZS 1680.2.5:1997 2.5

GENERAL SPECIFICATIONS

Replaces: T8 (26mm) Fluorescent (G13 lamp caps)

Diffuser: Frosted Polycarbonate (165° beam angle)

Rotating End Caps: 180° (+/- 90°) with locking latch

Efficacy (incl driver): 115 Lumens per Watt (4 foot frosted)

Colour Temperature: 4000 K (nominal) (3300K to 5300K to order)

Rated Lamp Life: >35,000 hours (L70 LM-80/TM-21)

ORDERING CODES Clinical Observation 4000K Frosted

Model Number Nom. Length

Power (LCP)

Rated Output

CIT-06-08W-FR40-CO 2 foot 7.22 W 950 lm

CIT-12-17W-FR40-CO 4 foot 16.82 W 2000 lm

CIT-15-23W-FR40-CO 5 foot 22.34 W 2675 lm

CYANOSIS OBSERVATION Compliant with Australian Standard

AS/NZS 1680.2.5:1997

Technica l Data

VEET APPROVED PRODUCT Energy savings scheme compliant

The CIT “Clinical Observation” models share most features

with the wide range of Carinda ‘CIT Series’ LED Tubes.

The Light Output, Colour, CRI and Power of each product range are tailored to suit specific project specifications.

Please refer to the other CIT Series Data Sheets for full details

ZERO

IR+UV

NOTE: This model range can also be manufactured in high output versions

SPECTRAL ENERGY DISTRIBUTION POLAR CURVE

Rev 1.1c – 28/05/15

Page 2: LED Tubes for CLINICAL OBSERVATION Technical …LED Tubes for CLINICAL OBSERVATION CARINDA INTERNATIONAL PTY LTD 32/10 Gladstone Rd, Castle Hill, NSW 2154 Ph: (02) 9894 9800 Fax: (02)

LED Tubes for CLINICAL OBSERVATION

CARINDA INTERNATIONAL PTY LTD 32/10 Gladstone Rd, Castle Hill, NSW 2154 Ph: (02) 9894 9800 Fax: (02) 9634 2708

Email: [email protected]

Due to rapidly advancing technology, Carinda’s LED range is under continuous development and product improvement. Carinda reserves the right to change or alter any information and/or specifications without notice. Installation should be undertaken by a licenced electrician and in strict accordance with the instructions provided to ensure safety and for warranty compliance.

www.carinda.com.au

ABOUT CYANOSIS

Cyanosis is a bluish discolouration in the skin, indicating that oxygen levels in the blood are dangerously depleted. Whilst pulse oximeters are commonly used in medical facilities, there are many situations and medical conditions where they are unsuitable. Therefore visual observation to reliably detect Cyanosis is still critical for patients’ wellbeing.

Australian Standard AS/NZS1680.2.5 specifies the particular requirements for illumination in these Clinical Observation areas. High Colour Rendering Index (CRI) and sufficient red at wavelengths greater than 600nm are required to achieve the mandatory Cyanosis Observer Index (COI) of less than 3.3.

Conventional 8xx & 9xx Series fluorescent tubes cannot meet the COI requirements; the specialised “Hospital White” tubes that are commonly installed have notoriously poor efficiency (around 50 Lumens per Watt) and relatively lamp short life.

Luminaires used for clinical observation, operating theatres, emergency areas, and autopsy / mortuary labs are usually IP65 “Cleanroom” units that are sealed to the ceiling to eliminate hygiene risks.

These luminaires are difficult to open for service, so long lamp life is paramount. Since these sealed fixtures are extremely expensive to replace, an economical tube-only retrofit is the ideal solution to minimise the total cost of upgrading existing installations and reducing energy consumption.

THE FIRST GENERATION LED PRODUCTS

LED lamps are certainly revolutionalising the lighting market, and standard white LEDs are made cost effective by using a blue chip with a yellow phosphor coating to create the appearance of “white light”. The spectral emission of these conventional chips show distinct spikes in blue and yellow, and low levels of the vitally important red light above 600nm.

A few manufacturers have worked around the limitation by adding approximately 20% of red LED chips. Whilst improving the COI performance, it is not optimum since numerous red chips significantly reduce the efficiency of the overall package.

CARINDA’S INNOVATIVE SOLUTION

“True White” has been developed by Carinda to solve the inherent inability of standard white LED products to meet the stringent COI criteria for Clinical Observation areas.

Uniquely customised SMD LED chips have a specially formulated structure and phosphors that provide far more balanced light output, with reduced peaks in blue and yellow and substantially increased deep red lighting.

Performance is outstanding – over 115 Lumens per Watt from the 4 foot frosted T8 tube, which is unparalleled for a diffused LED product with a CRI of over 90. In combination with the numerous features and benefits of Carinda’s CIT LED Tube range, the upgrade of the old fluorescent lights in Clinical Observation areas has finally become financially viable.

This diagram compares the spectral light output of the new Carinda “True White” COI chips to standard 4000K LEDs:

NUMEROUS ADVANTAGES COMPARED TO FLUORESCENT

“True White” LED tubes provide equivalent lighting performance to the commonly used “Hospital White” style T8 fluorescent tubes, together with many notable advantages:

System efficacy is significantly increased from around 52 lm/W to 115 lm/W (around 55% more energy efficient).

Lamp life is doubled from <20,000 to over 36,000 hours.

Instant illumination to 100% (no warm up time).

Flicker-free illumination, both when starting and also during operation, provides excellent visual comfort.

LED lamp life is not decreased by frequent switching, so occupancy-based control systems become viable to save further energy in less frequently used areas.

Please refer to Carinda’s CIT Series product data sheets for full information about LED Tubes using this technology.

Rev 1.1c – 28/05/15

Much higher

percentage

of reds

CYANOSIS OBSERVATION Compliance with Australian Standard

AS/NZS 1680.2.5:1997