7
LIFA AIR ® – Air duct cleaning Machines for air ducts and industrial process pipeline cleaning

LIFA AIR – Air duct cleaning · LIFA AIR® – Air duct cleaning Machines for air ducts and industrial process pipeline cleaning. 2 Industrial processes always cause various by-products

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: LIFA AIR – Air duct cleaning · LIFA AIR® – Air duct cleaning Machines for air ducts and industrial process pipeline cleaning. 2 Industrial processes always cause various by-products

LIFA AIR® – Air duct cleaning Machines for air ducts and industrial process pipeline cleaning

Page 2: LIFA AIR – Air duct cleaning · LIFA AIR® – Air duct cleaning Machines for air ducts and industrial process pipeline cleaning. 2 Industrial processes always cause various by-products

2

Industrial processes always cause various by-products and contami-nants which need to be removed from exhaust systems and/or process pipelines regularly. Clean and functional exhaust/pipeline system also prevents fire hazards, cross-contamination and reduces energy consump-tion. Cleaning done with Lifa Air dry removal method saves both time andusage of chemicals and water, thus resulting into more economic and environmental friendly result.

RECOMMENDED EQUIPMENT• Combi Cleaner 40• Combi Cleaner 15• Hydmaster 40• Special Cleaner 25 Multi• Duct Control Cleaning Robot

I N D U S T R I A L E X H A U S T D U C T S A N D P R O C E S S P I P E S

Hydmaster 40Electric-hydraulic brushing machine

for 400 - 1200 mm ducts

Reference examples:Food processingAutomotive manufacturiingWood, paper and pulp industriesMedicine and other clean room technologie

Before After

Page 3: LIFA AIR – Air duct cleaning · LIFA AIR® – Air duct cleaning Machines for air ducts and industrial process pipeline cleaning. 2 Industrial processes always cause various by-products

Grease accumulation in exhaust ducts is a fire danger which can cause the whole building to be damaged. Therefore ducts need to cleaned regularly – as per how many hours kitchen is used per day – in order to keep this accumulation = threat in minimum at all times. Clean and functional exhaust system also prevents odours and heat rise from escaping to other areas.

RECOMMENDED EQUIPMENT• Combi Cleaner 40• Combi Cleaner 15• Hydmaster 40• Special Cleaner 25 Multi• Extra strong driller shafts

K I T C H E N E X H A U S T G R E A S E

Combi Cleaner 40Pneumatic brushing machine

for 400 - 1200 mm ducts

Reference examples:Hamburger restaurants (all global brands, all over the world)Hotel kitchens (all global brands, all over the world)Italian restaurants

Before After

3

Page 4: LIFA AIR – Air duct cleaning · LIFA AIR® – Air duct cleaning Machines for air ducts and industrial process pipeline cleaning. 2 Industrial processes always cause various by-products

4

HVAC systems in commercial buildings need to be regularly inspected and cleaned in order to keep the building - and it’s occupants - healthy. Unfortunately due to lack of maintenance and energy savings ventilation systems actually are too often the very cause for Sick Building Syndrome (SBS) and Building Related Illness (BRI).

RECOMMENDED EQUIPMENT• Combi Cleaner 40• Combi Cleaner 15• Hydmaster 40• Special Cleaner 25 Multi• Duct Control Cleaning Robot

C O M M E R C I A L M U L T I - S T O R E YB U I L D I N G S

Special Cleaner 25 MultiElectric brushing machine for 250 - 800 mm ducts

Reference examples:HospitalsOffice buildingsSchool and kindergartenResidential blocks or flats

Before After

Page 5: LIFA AIR – Air duct cleaning · LIFA AIR® – Air duct cleaning Machines for air ducts and industrial process pipeline cleaning. 2 Industrial processes always cause various by-products

Dryer vents is by far the greatest risk of fire in relation to HVAC in residen-tial houses. Secondly, kitchen exhaust ductwork. However, in long term, dust accumulated in ducts, heat exhagers etc. will be the source microbial growth (mold/mildew) and/or increase the amount of energy usage.

RECOMMENDED EQUIPMENT• Combi Cleaner 40• Special Cleaner 20• Driller shafts

R E S I D E N T I A L H O U S E S

Special Cleaner 20Electric brushing machine

for ø 100 - 400 mm ducts

Reference examples:Single housesTerraced houses

Before After

5

Page 6: LIFA AIR – Air duct cleaning · LIFA AIR® – Air duct cleaning Machines for air ducts and industrial process pipeline cleaning. 2 Industrial processes always cause various by-products

6

Large ducts Small ducts

Hydmaster 40 Combi Cleaner 40 Special Cleaner 25 Multi

Duct Control Cleaning Robot

Special Cleaner 20 Combi Cleaner 15

Operating power Electric-hydraulic Compressed air Electricity Compressed air (brush) + electricity (driving)

Electricity Compressed air

Operating voltage and frequency

240 VAC (or 110-120 VAC), 1~, 50/60 Hz

- 240 VAC (or 110-120 VAC), 1~, 50/60 Hz

12 VCD 240 VAC (or 110-120 VAC), 1~, 50/60 Hz

-

Motor 1,1 kW (1,5 HP)

0,4 kW(0,6 HP)

0,75 kW (1,0 HP)

0,11 kW (0,15 HP)

0,37 kW (0,5 HP)

0,11 kW (0,15 HP)

Fuse 16 A - 10 A 5 A 10 A -

Max. torque 10 Nm 6,5 Nm 5 Nm 3 Nm 5 Nm 3 Nm

Brush connection

M12 M12 M12 M12 M12 M12

Brush size recommendation

400 - 1200 mm 400 - 1200 mm 250 - 800 mm 200 - 600 mm 100 - 400 mm 160 - 600 mm

Brush rotation speed

Continuous adjustment, 225 - 880 rpm

Continuous adjustment, max. 670 rpm

Continuous adjustment, 225 - 580 rpm

Continuous adjustment, max. 1000 rpm

Continuous adjustment, 225 - 580 rpm

Continuous adjustment, max. 1000 rpm

Rotation controls Foot pedal, remote hand control

Manual / Air Valve

Foot pedal, remote hand control (accessory)

Manual / Air Valve Foot pedal / remote hand control (acces-sory)

Manual / Air Valve

Nozzle connection - Quick coupling Quick coupling Quick coupling - Quick coupling

Air volume consumption

- 400 l/min., 7 bar Nozzle type dependant

340 l/min., 7 bar - 340 l/min., 7 bar

Measurements (mm)

H: 1290L: 1100W: 570

H: 1290L: 1100W: 570

H: 1290L: 1100W: 570

H: 190L: 410W: 280

H: 910L: 640W: 480

H: 910L: 640W: 480

Weight 93 kg 45 kg 71 kg 8 kg 38 kg 17 kg

Cleaning shaft 40 m 40 m 25 m 25 m (driving cable)

20 m 15 m

Accessories Y-gear, 3-brush-gear, mechanical cente-ring device, hand controller

Y-gear, 3-brush-gear, mechanical centering device, hand controller

Y-gear,mechanical centering device, hand controller, spray bottle, nozzles

Y-gear, 3-brush-gear, spray bottle, nozzles

Mechanical cente-ring device, hand controller

Y-gear,mecha-nical centering device, hand controller, spray bottle, nozzles

Scope

Page 7: LIFA AIR – Air duct cleaning · LIFA AIR® – Air duct cleaning Machines for air ducts and industrial process pipeline cleaning. 2 Industrial processes always cause various by-products

MEZ-TECHNIK GmbHBierwiesenstrasse 772770 Reutlingen

Tel.: +49 (7072) 600980Fax: +49 (7072) 6009860

[email protected]