38
LIGHTING CONSTRUCTION MANUAL INTRODUCTION Go to NEXT PAGE Back to MAIN INDEX

LIGHTING CONSTRUCTION MANUAL - Energex · PDF fileQueensland Public Lighting Construction Manual Check this is the latest version before use. i EX RED 00796 Ver 5 Joint Standard Document

  • Upload
    ledang

  • View
    223

  • Download
    1

Embed Size (px)

Citation preview

LIGHTING CONSTRUCTION MANUAL

INTRODUCTION

Go to NEXT PAGE Back to MAIN INDEX

Queensland

Public Lighting

Construction Manual

Queensland Public Lighting

Construction Manual

Check this is the latest version before use. i EX RED 00796 Ver 5

Joint Standard Document between Energex and Ergon Energy

Energex Limited ABN 40 078 849 055 Ergon Energy Corporation Limited ABN 50 087 646 062

Table of Contents

SECTION 1 – Introduction & Cross Reference Tables

SECTION 2 – Assemblies

SECTION 3 – Construction Practices

SECTION 4 – Services

SECTION 5 – Columns Major Roads

SECTION 6 – Columns Minor Roads

SECTION 7 – Pole Brackets Major Roads

SECTION 8 – Pole Brackets Minor Roads

SECTION 9 – Floodlighting

SECTION 10 – Telstra Approved Hardware

SECTION 11 – Bulkhead Luminaires

SECTION 12 – PE Cell Conversion

SECTION 13 – Control Wiring

Queensland

Public Lighting

Construction Manual

Section 1 – Introduction & Cross

Reference Tables

Queensland Public Lighting

Construction Manual

Check this is the latest version before use i EX RED00796 Ver 5

Joint Standard Document between Energex and Ergon Energy

Energex Limited ABN 40 078 849 055 Ergon Energy Corporation Limited ABN 50 087 646 062

Section 1

Table of Contents

1 Distributors’ Contact Details ................................................................... 1

2 Dial Before You Dig .................................................................................. 2

3 Foreword ................................................................................................... 3

4 Definitions, Abbreviations and Acronyms ............................................. 5

5 References ................................................................................................ 7

5.1 Joint controlled document .................................................................................... 7

5.2 Energex controlled document .............................................................................. 7

5.3 Ergon Energy controlled documents .................................................................... 7

5.4 Other documents ................................................................................................. 7

6 Purpose and Scope .................................................................................. 8

7 Structure of Construction Manual ........................................................... 8

Appendix 1 – Amendments As Contained in Version 5 ................................................ 12

Appendix 2 – Energex Standards Alerts Reconciliation .............................................. 16

Appendix 3 – Energy Queensland Procedure for Reporting a Problem or

Improvement with the Construction Manuals ...................................... 19

Appendix 4 – Drawing Cross References ...................................................................... 22

Queensland Public Lighting

Construction Manual

Check this is the latest version before use 1 EX RED 00796 Ver 5

Joint Standard Document between Energex and Ergon Energy

Energex Limited ABN 40 078 849 055 Ergon Energy Corporation Limited ABN 50 087 646 062

1 DISTRIBUTORS’ CONTACT DETAILS

Energex

Web Address www.energex.com.au

Public Lighting Enquiries via

General Customer Service

13 12 53

General Customer Service - Email E-mail requests can be sent to

[email protected] or by

completing the Contact Form as provided

under “Contact Us” on the Energex Web

site: www.energex.com.au

Loss of Supply 13 62 62

Emergencies 13 19 62

Ergon Energy

Web Address www.ergon.com.au

General Customer Service - Phone 13 10 46

General Customer Service - Email E-mail requests can be sent to

[email protected] or by

completing the Contact Form as provided

under “Contact Us” on Ergon Energy’s

Web site: www.ergon.com.au

24 Hour Faults 13 22 96

Life-Threatening Emergencies 000 or 13 16 70

Queensland Public Lighting

Construction Manual

Check this is the latest version before use 2 EX RED 00796 Ver 5

Joint Standard Document between Energex and Ergon Energy

Energex Limited ABN 40 078 849 055 Ergon Energy Corporation Limited ABN 50 087 646 062

2 DIAL BEFORE YOU DIG

Phone 1100 - free call (except from mobiles) Fax 1300-652-077

Website www.1100.com.au

Dial before you Dig is the national referral service for information on the location of underground

infrastructure.

Australia’s major service providers have a single web-enabled information service for information

on the location of underground communications, gas, water and electricity infrastructure.

The Dial before you Dig online service is available 24 hours a day and enables users to have more

control over their enquiry as you detail the dig site on the mapping software yourself.

Use the website to ensure that you ‘Dial Before You Dig’ before any excavation work.

When calling the 1100 phone number the operator may require the following:

your name and address

name of company

contact telephone number

fax number for return information

contact name on site

site address and both nearest cross streets

start date of proposed work

type of work being carried out

Note: WP1323 / BS001405R107 Electricity Entity Requirements: Working Near Overhead and

Underground Electric Lines has requirements for excavating near underground electrical

services.

ASBESTOS WARNING

Older type conduits may contain asbestos. Electrical workers who are required to work on these

need to identify if this hazard is present and, if necessary, take appropriate action.

Asbestos information is available on the Workplace Health and Safety Queensland web site

www.worksafe.qld.gov.au under the heading “Injury Prevention & Safety”.

Queensland Public Lighting

Construction Manual

Check this is the latest version before use 3 EX RED 00796 Ver 5

Joint Standard Document between Energex and Ergon Energy

Energex Limited ABN 40 078 849 055 Ergon Energy Corporation Limited ABN 50 087 646 062

3 FOREWORD

The Queensland Public Lighting Construction Manual has been compiled in conjunction with the Network Engineering Standards Department of Energex and the Network Standards Department of

Ergon Energy.

Note: Printed versions of the Manual are “uncontrolled copies” - the latest version is available on

the Energex website (www.energex.com.au) or Ergon Energy website (www.ergon.com.au).

Safety

In all activities undertaken, the safety of our employees, contractors, customers and the community

is paramount. Safety is our number one value and there is a commitment to ensuring that "safety

must come first" to achieve a no injuries workplace. In accordance with legislative requirements

we have developed Policies, Standards and Work Practices that our workers are required to follow

to ensure the safety of themselves, other workers, customers and the community. We trust that

electrical contractors and persons in control of sites will appreciate that our workers will not

undertake any work in a situation where there are uncontrolled risks inconsistent with our safe

systems of work.

Disclaimer

Whilst the Public Lighting Construction Manual contains material relevant to the electricity industry

legislation, codes of practice and standards, it is not intended to provide legal advice on how

electrical contractors can meet their own statutory obligations or comply with legislation, codes of

practice or industry standards such as AS/NZS 3000 (Wiring Rules).

This document does not provide advice for the purposes of Part 5 of the Electrical Safety

Regulation 2013. The Electrical Safety Act 2002, Electrical Safety Regulation 2013 and associated

codes of practice establish requirements for electrical safety and place obligations on employers,

self-employed persons and others. These documents may be obtained from the Queensland

Government website (www.justice.qld.gov.au) and (www.legislation.qld.gov.au).

Whilst care has been taken in the preparation of the Public Lighting Construction Manual, the

distribution entities do not guarantee that the information contained in the Public Lighting

Construction Manual is accurate, complete or up to date at time of publication. To the extent

permitted by the relevant legislation the DNSP will not be responsible for any loss, damage, cost or

expense incurred as a result of any error, omission or misrepresentation in relation to the

information contained in the Public Lighting Construction Manual.

Any proposed deviation from this document must be submitted to Energex or Ergon Energy in

writing with full descriptions and details for approval before it is implemented. Allowance should be

made to ensure Energex and Ergon Energy are provided with sufficient time for full and in-depth

consultation and deliberation.

In the event that any user of this manual considers the content uncertain, ambiguous or otherwise

in need of interpretation, the user may request Energex or Ergon Energy to clarify the provision.

Should further review be required, the provisions of the previous clause “General” will need to be

followed.

Queensland Public Lighting

Construction Manual

Check this is the latest version before use 4 EX RED 00796 Ver 5

Joint Standard Document between Energex and Ergon Energy

Energex Limited ABN 40 078 849 055 Ergon Energy Corporation Limited ABN 50 087 646 062

When downloaded or printed, this document is uncontrolled. This document is subject to

amendment Jointly by Energex and Ergon Energy at any time. Note: Users are responsible for

ensuring they are using the latest information.

This document has been developed using information provided by Energex and Ergon Energy

Construction, Planning and Design staff and as such is suitable for most situations encountered.

The requirements of Australian Standards, Building Codes and all other statutory bodies are

regarded as the accepted minimum requirements for the establishment of Public Lighting

installations. Where this document exceeds those requirements, this document is to become the

accepted minimum.

Energex and Ergon Energy will not accept any liability for work carried out to a superseded

standard. Energex and Ergon Energy also may not accept work carried out that is not in

accordance with current standard requirements. This manual is subject to ongoing review. If

conflict exists between manuals, the requirements of the most recent manual are to be adopted.

A proprietary item is any item identified by graphic representation on the drawings, or by naming

one or more of the following: manufacturer, supplier, installer, trade name, brand name, catalogue

or reference number, and the like. The identification of a proprietary item is a recommendation

ONLY. It indicates the required properties of the item, such as the type, quality, appearance,

finish, method of construction and performance.

More than one supplier or product is capable of meeting this Specification. An alternative/

equivalent item is permissible, provided that it meets the relevant performance criteria and is

otherwise of a quality reasonably satisfactory to Energex and Ergon Energy.

No claim shall arise from any rejection by Energex and Ergon Energy of an alternative/equivalent

item.

The acceptance of an alternative/equivalent item shall not be grounds for a variation to cost or

time. When offering an alternative/equivalent item, the Contractor is to provide all available

technical information, and any other relevant information requested by Energex or Ergon Energy.

If requested by Energex or Ergon Energy, the Contractor is to obtain and submit reports on

relevant tests by an independent testing authority.

Copyright

Copyright © 2010 Energex Limited and Ergon Energy Corporation Limited. This publication is

copyright. Except as permitted under the Copyright Act 1968 no part of this publication may be

reproduced by any process without the specific written permission of the copyright owner.

All rights reserved.

Queensland Public Lighting

Construction Manual

Check this is the latest version before use 5 EX RED 00796 Ver 5

Joint Standard Document between Energex and Ergon Energy

Energex Limited ABN 40 078 849 055 Ergon Energy Corporation Limited ABN 50 087 646 062

4 DEFINITIONS, ABBREVIATIONS AND ACRONYMS

Term Definition

Aeroscreen Luminaire

A luminaire where the intensity at or near the horizon is restricted in

accordance with the requirements of the aviation authorities. They are

commonly called ‘full cut-off luminaires’ describing luminaires that emit no light

above the horizontal plane.

Arrangement The layout, in plan, of the luminaires in a lighting scheme, e.g. single sided,

staggered, opposite or central along roadways.

Carriageway

That portion of the road devoted to the use of vehicles, inclusive of shoulders

and auxiliary lanes. An undivided road, either one way or two way, comprises

a single carriageway. A road divided longitudinally by a median or similar

comprises two carriageways.

Conflict Points

Roadway features that influence the passage of motorists and pedestrians and

that require particular attention when preparing the lighting design e.g.

chevrons, pedestrian refuges, gore points at off / on ramps.

Customer Owned and

Operated (previously Rate

3)

Public Lighting supplied, installed, owned and maintained by the Public Body.

Supply is unmetered and has a fixed wattage and must comply with the

AS/NZS 3000 Wiring Rules. Beyond the Point of Supply, reticulation is owned

and maintained by the consumer.

DNSP

(Distribution Network Service Provider) Corporations that are responsible for

electricity distribution in Queensland e.g. Energex Limited and Ergon Energy

Limited.

Energex Contributed (Rate

2) Public lighting owned and maintained by the Electricity Entity.

Energex Non Contributed

(Rate 1)

Public lighting supplied, installed, owned and maintained by the Electricity

Entity. The tariff includes components supply and installation and recovery

over time.

Energex Unmetered (Rate

3)

Public Lighting supplied, installed, owned and maintained by the Public Body.

Supply is unmetered and has a fixed wattage and must comply with the

AS/NZS 3000 Wiring Rules. Beyond the Point of Supply, reticulation is owned

and maintained by the consumer.

Energex Unmetered (Rate

8)

Public Lighting supplied, installed, owned and maintained by a customer who

is not a Public Body. Supply is unmetered and has a fixed wattage and must

comply with the AS/NZS 3000 Wiring Rules. Beyond the Point of Supply,

reticulation is owned and maintained by the consumer.

Ergon Owned and

Operated (previously Rate

1)

Public Lighting supplied, installed, owned and maintained by Ergon Energy.

Funding Arrangements

The determination of who provides the funding for the installation. In the case

of a Rate 1 installation, the electricity distributor funds the design and

construction of the installation. In the case of a Rate 2 installation, the Public

Body or developer funds the design and construction of the installation.

Queensland Public Lighting

Construction Manual

Check this is the latest version before use 6 EX RED 00796 Ver 5

Joint Standard Document between Energex and Ergon Energy

Energex Limited ABN 40 078 849 055 Ergon Energy Corporation Limited ABN 50 087 646 062

Term Definition

Gifted and Ergon Operated

(previously Rate 2)

Public Lighting Gifted to and thereafter operated and maintained by Ergon

Energy.

Glare

Conditions of vision in which there is discomfort or a reduction in the ability to

see, or both, caused by an unstable distribution or range of luminance, or

extreme contrasts in the field of vision.

Illuminance The physical measure of illumination. It is the luminous flux arriving at a

surface divided by the area of the illuminated surface.

Lamp The generic term for the light source in a luminaire.

Lighting Column A vertical structure of any appropriate material, which, is designed to support

luminaires either directly or by use of outreach arms or mounting frames.

Luminaire

Apparatus which distributes, filters, or transforms the light transmitted from one

or more lamps and which includes, except for the lights themselves, all the

parts necessary for fixing and protecting the lamps and, where necessary,

circuit auxiliaries together with the means for connecting them to the electrical

supply.

Luminance

The physical quantity corresponding to the brightness of the surface (lamp,

luminaire or reflecting material such as the road surface) when viewed from a

specified direction.

Metered Lighting Lighting on private roads, walkways, open areas etc., that are not dedicated

public roads.

Mounting Height The vertical distance between the photometric centre of a luminaire and the

surface which is to be illuminated e.g. the road surface.

Outreach

The distance, measured horizontally, from the photometric centre of a

luminaire to:

a. for lighting columns with outreach arms, the centre of the vertical section

of the pole

b. for bracket arms, the mounting plate by means of which the bracket arm is

secured to the pole, or wall or other supporting surface.

Public Body

Organisations defined as Road Controlling Authorities and include Local

Government, Department of Transport and Main Roads or other Queensland

Government Departments and Queensland Public Authorities as approved by

the Queensland State Government.

Public Lighting

(Road Lighting) Lighting for any roadway, pathway or dedicated public

thoroughfare, park or precinct (Lighting provided in accordance with the

AS/NZS 1158 series).

Roadway Width

The traverse distance between the outer road kerb-lines or edges (for divided

roads, this will apply to the two carriageways plus the intervening median

strip). Roadway width is used only for the lighting of curves.

Tilt (Upcast) Angle The angle by which the axis of the fixing spigot entry is tilted above the

horizontal when the luminaire is installed.

Queensland Public Lighting

Construction Manual

Check this is the latest version before use 7 EX RED 00796 Ver 5

Joint Standard Document between Energex and Ergon Energy

Energex Limited ABN 40 078 849 055 Ergon Energy Corporation Limited ABN 50 087 646 062

5 REFERENCES

5.1 Joint controlled document

Energex Document

Number

Ergon Energy

Document Number Document Name

00294 NA000403R328 Queensland Electricity Connection and Metering Manual

(ECMM)

WP1323 BS001405R107 Electricity Entity Requirements – Working Near Overhead

and Underground Electric Lines

00767 NA000403R434 Queensland Public Lighting Design Manual

5.2 Energex controlled document

Document Number Document Name Document Type

00576 Standard Conditions for Public Lighting

Services Manual

00305 Energex Underground Distribution Construction

Manual (UDC) Manual

Energex Overhead Construction Manual

(OHCM) Manual

5.3 Ergon Energy controlled documents

Document Number Document Name Document Type

Ergon Energy Overhead Construction Manual Standard

Ergon Energy Underground Construction

Manual Standard

Standard Conditions for Public Lighting

Services

5.4 Other documents

Nil.

Queensland Public Lighting

Construction Manual

Check this is the latest version before use 8 EX RED 00796 Ver 5

Joint Standard Document between Energex and Ergon Energy

Energex Limited ABN 40 078 849 055 Ergon Energy Corporation Limited ABN 50 087 646 062

6 PURPOSE AND SCOPE

The purpose of this manual is to promote industry uniformity through standardisation of equipment

and practices throughout Queensland. The document is for use by Design & Construction Staff,

Consulting Engineers, Architects and others directly concerned with Public Lighting Installations

that are connected to the respective supply networks.

Manufacturing/fabrication drawings are not included in this manual but are detailed in both the

QESI, Energex Public Lighting Specifications, and the Ergon Energy Distribution Network

Hardware manual.

This manual is to be used in conjunction with the Queensland Public Lighting Design Manual and

the relevant DNSP’s Standard Conditions for Public Lighting Services. These documents will

serve as a valuable instrument by which efficient and economic constructions complying with

relevant codes of practice and guidelines can be constructed throughout both DNSP’s respective

areas of supply.

Difficulties experienced in using this manual, or suggestions for improvement should be entered on

the Construction Standards Feedback Form NA000303F100 in accordance with the Procedure

NA000303 (see Appendix 3 ).

7 STRUCTURE OF CONSTRUCTION MANUAL

General

The broad structure of the Public Lighting construction manual is segregated into Volume, Folder,

Page. Any one page may comprise of multiple individual drawing sheet numbers. For this entire

manual, the Volume is always 1. Page 1 of each Folder contains Indices and Page 2 references to

Construction Types and Cross References. There are a total of 13 Folders comprising the

following:

Queensland Public Lighting

Construction Manual

Check this is the latest version before use 9 EX RED 00796 Ver 5

Joint Standard Document between Energex and Ergon Energy

Energex Limited ABN 40 078 849 055 Ergon Energy Corporation Limited ABN 50 087 646 062

Volume Folder Pages Description Usage

1 1 1-6 Introduction, Amendments & Indices Joint

1 2 800-903 Assemblies Joint

1 3 1-17 Construction Practices Joint

1 4 1-15 Services Joint

1 5 1-19 Major Road Columns Joint

1 6 1-7 Minor Road Columns Joint

1 7 1-9 Pole Brackets Major Roads Joint

1 8 1-5 Pole Brackets Minor Roads Joint

1 9 1-11 Floodlighting Joint

1 10 8 Joint Use Joint

1 10 3-7 Telstra Mobile Phones Energex Only

1 11 1-4 Bulkhead Luminaires Energex Only

1 12 1-9 PE Cell Conversion Joint

1 13 1-6 Control Wiring Energex Only

The new structure of this manual has separated construction and assembly detail for any particular

construction type and places these in separate drawing folders. The construction drawings now

include broad diagrammatic and installation notes for the unique construction types, and each refer

to multiple assembly drawings that constitute that particular type.

Figure 3: Construction -

Material List

Figure 3: Construction -

Installation

Figure 3: Multiple Assembly Drawings

Queensland Public Lighting

Construction Manual

Check this is the latest version before use 10 EX RED 00796 Ver 5

Joint Standard Document between Energex and Ergon Energy

Energex Limited ABN 40 078 849 055 Ergon Energy Corporation Limited ABN 50 087 646 062

Stock codes for all equipment and materials for both corporations are now indicated in an

assembly drawing section 1-2-8XX and appear in no other documents. These are quoted on an

equivalence basis where there are common assemblies. Constructions and Assemblies unique to

either corporation are indicated in the drawing title bar as “ENERGEX / ERGON ONLY”, with

tabular entries corresponding to the other entity’s stock codes in associated Assembly drawings

denoted “NIL”.

It should be noted that minor variances in purchasing arrangements between the two corporations

have some equivalent assembly items packaged as a bundle under one stock code by one

corporation and represented by a group of stock codes by the other. These variances are catered

for in the Assembly stock code tables and do not represent omissions.

This manual also aligns to the terminology of the Australian Standards AS/NZS1158 in relation to

Luminaires and Lamps.

A detailed cross reference of all legacy Energex drawings can be found in drawings 1-1-1 & 2. A

list of all new drawings that include also those that are being redrafted from the Legacy Energex

manual can be found in drawings 1-1-4, 5 & 6.

Construction Code Types noted in Sheets at the commencement of each Drawing Folder on Page

2, (following indices on Page 1) detail Types.

Figure 4: Example of

Ergon Only Assembly

Figure 5: Example of

Bundled Items

Queensland Public Lighting

Construction Manual

Check this is the latest version before use 11 EX RED 00796 Ver 5

Joint Standard Document between Energex and Ergon Energy

Energex Limited ABN 40 078 849 055 Ergon Energy Corporation Limited ABN 50 087 646 062

Assembly manufacturing drawings have now been removed from the Energex Construction

Manual and are now attached to individual procurement specifications.

A cross reference of all legacy Ergon Energy drawings detailed in drawing 1-1-3. A list of all new

drawings can be found in drawings 1-1-4,5 & 6.

Figure 6: Example Construction

Code Type

Queensland Public Lighting

Construction Manual

Check this is the latest version before use 12 EX RED 00796 Ver 5

Joint Standard Document between Energex and Ergon Energy

Energex Limited ABN 40 078 849 055 Ergon Energy Corporation Limited ABN 50 087 646 062

APPENDIX 1 – AMENDMENTS AS CONTAINED IN VERSION 5

Folder Page No. Brief Description of Amendments

1

Introduction

Version 5 of the Introduction, correction of grammatical errors and update to the

construction type guide for Energex. Updated the corporate logos to include the

Energy Queensland branding.

2-1 (E)

Revised to reflect current amendment version of drawings included in manual

release. 2-2 (E)

2-3 (E)

3-1 (A) New drawings for Electric Office terminology changes.

3-2 (A)

2

1-2 (E)

Index revised. 1-3 (E)

1-4 (E)

1-5 (A) New Index drawing.

801 (D) 20A Fuse Link added as option for Ergon Energy Construction.

806 (D) 400W Metal Halide aeroscreen luminaire removed for Ergon Energy.

808 (B) Update Energex stock code for 1.5m outreach extension.

816 (E)

LED luminaire 17 W, 25 W & 30 W stock codes added for Energex.

Assemblies 816-26 to 816-29 added for Energex.

Note Energex Stock code is the same as the Ergon Energy stock code.

817 (E) LED luminaire 17 W & 25 W stock codes added for Energex.

Note Energex Stock code is the same as the Ergon Energy stock code.

831 (D)

Cable clamp & Connector set stock codes added for Ergon Energy for

maintenance activities.

Junction Box kit remains supplied with all required materials for new

constructions.

832 (B) Energex stock code for the terminal panel updated.

834 (C) Assembly 834-4 added for Energex Metered label to concrete pole.

835 (B) Energex stock code for “3” self-adhesive label updated.

843 (E)

LED luminaires 17 W, 25 W & 30 W stock codes added for Energex.

Assemblies 843-21 to 843-26 added for Energex.

Note Energex Stock code is the same as the Ergon Energy stock code.

847 (D) Energex stock codes for fuse holder updated.

848 (B) Ergon Energy Floodlight construction moved to assembly 911.

851 (B) Energex only label removed.

852 (B)

Queensland Public Lighting

Construction Manual

Check this is the latest version before use 13 EX RED 00796 Ver 5

Joint Standard Document between Energex and Ergon Energy

Energex Limited ABN 40 078 849 055 Ergon Energy Corporation Limited ABN 50 087 646 062

Folder Page No. Brief Description of Amendments

853 (C) Ergon Energy stock code for S250 luminaire removed.

854 (B) 9.0 m & 10.5 m mid hinged BPM pole added. (Energex Only)

867 (D)

Cable clamp & Connector set stock codes added for Ergon Energy for

maintenance activities.

Junction Box kit remains supplied with all required materials for new

constructions.

902 (C) Stock codes added for M125, M250 & M400 replacement lamps.

905 (A) New drawing LORA and antenna to steel pole. (Ergon Energy Only)

906 (A) New drawing bandit strap to steel pole. (Ergon Energy Only)

907 (A) New drawing round Class ‘B’ streetlight pits single phase. (Ergon Energy Only)

908 (A) New drawing round Class ‘B’ streetlight pits three phase. (Ergon Energy Only)

909 (A) New assembly added for cable guard to pole. (Ergon Energy Only)

910 (A) New assembly added for Neutral screen cable terminated to overhead. (Ergon

Energy Only)

911 (A) New drawing floodlight assembly. (Ergon Energy Only)

3

1-1 (D) Index revised.

2-2 (B) Construction code added for Aldridge luminaire.

2-3 (A) New drawing. Construction code for Energex Service Cable added. (Energex

Only)

5-1 (C) Energex stock code added for stone guard.

6-3 (B) Depiction of label updated to reflect current labelling.

19-1 (A)

New drawing showing the installation of Class ‘B’ pit. (Ergon Energy Only) 19-2 (A)

19-3 (A)

4

1-1 (D) Index revised.

2-2 (C) New construction code added for Class ‘B’ pits. (Ergon Energy Only)

2-4 (A) New drawing added, construction code for Underground streetlight service from

overhead. (Ergon Energy Only)

8-1 (B) Assemblies added for Class ‘B’ pit constructions.

10-1 (D) Energex cable Type added.

16-1 (A) New drawings added for underground streetlight service from overhead. (Ergon

Energy Only) 16-2 (A)

5 2-1 (E) Construction Code added for the High mast outreaches.

6 1-1 (E) Index revised to reflect changes in the folder.

2-1 (E) LED Nostalgia Luminaire construction codes moved to 1-6-2-3.

Queensland Public Lighting

Construction Manual

Check this is the latest version before use 14 EX RED 00796 Ver 5

Joint Standard Document between Energex and Ergon Energy

Energex Limited ABN 40 078 849 055 Ergon Energy Corporation Limited ABN 50 087 646 062

Folder Page No. Brief Description of Amendments

2-2 (E) Luminaire construction codes moved to 1-6-2-3.

2-3 (A) New drawing added for luminaire construction codes.

2-6 (A)

3-1 (E) LED luminaire wattages updated to reflect information in assemblies. Spelling

error in title corrected. 3-2 (E)

4-2 (E) Add LED Luminaire Construction Type.

7 No changes in this folder.

8 2-2 (D) Construction Code added for LED Luminaires.

2-5 (C)

3-1 (E)

Drawings updated to include LED Luminaires.

3-2 (E)

4-1 (E)

4-2 (E)

5-1 (E)

5-2 (E)

6-1 (E)

6-2 (C)

9 2-1 (C) Floodlight type removed from construction code.

10

Divider Folder name changed from Telstra Approved Hardware to Joint Use

1-1 (D) Index revised and drawing title changed to align with folder name change.

2-1 (A) Construction Code added for Data Unit of streetlight pole. (Ergon Energy Only)

3-1 (B)

Drawing title updated to match folder name change.

3-2 (B)

3-3 (C)

3-4 (C)

4-1 (B)

5-1 (B)

6-1 (B)

6-2 (B)

7-1 (B)

7-2 (B)

8-1 (D)

8-2 (D)

Queensland Public Lighting

Construction Manual

Check this is the latest version before use 15 EX RED 00796 Ver 5

Joint Standard Document between Energex and Ergon Energy

Energex Limited ABN 40 078 849 055 Ergon Energy Corporation Limited ABN 50 087 646 062

Folder Page No. Brief Description of Amendments

9-1 (A) New drawing for Data Unit on streetlight pole. (Ergon Energy Only)

11 No changes in this folder.

12 5-2 (B) Construction Type reference corrected.

8-1 (B) Stock code for fuse holder updated.

13 No changes in this folder.

Queensland Public Lighting

Construction Manual

Check this is the latest version before use 16 EX RED 00796 Ver 5

Joint Standard Document between Energex and Ergon Energy

Energex Limited ABN 40 078 849 055 Ergon Energy Corporation Limited ABN 50 087 646 062

APPENDIX 2 – ENERGEX STANDARDS ALERTS RECONCILIATION

The following Standards Alerts are now either superseded, or remain current.

Date Alert Drawings

Impacted Description

Amendment

23/01/2017 StdsA364a

Minor Road LED Luminaires for

Public Lighting in the Energex

Area of Supply

Current

10/01/2017 StdsA364

Minor Road LED Luminaires for

Public Lighting in the Energex

Area of Supply

Archived

01/07/2016 StdsA359 Revised Queensland Public

Lighting Manual Ver 4 Current

27/07/2015 StdsA341 Streetlight Cabling Insulation

Requirements Current

28/04/2014 StdsA284 Luminaire Selection Guide for

Public Lighting Current

21/11/2013 StdsA269a Revised Queensland Public

Lighting Manual– Version 2 Archived

2/08/2013 StdsA269 Revised Queensland Public

Lighting Manual V2 Archived

16/04/2013 StdsA205a

Up-date of Public lighting

Design and Construction

Manuals April 2013

Current

16/11/2012 StdsA250 Revised Qld Public Lighting

Design Manual V2 Archived

19/12/2011 StdsA227

Street Light Equipment

Modification - Control Box for

OH Supply to Luminaires on

Steel Pole

Archived

5/09/2011 StdsA205

Update of - Queensland Public

Lighting Design Manual &

Queensland Public Lighting

Construction Manual

Archived

17/09/2010 StdsA178 Standard Conditions for Public

lighting Services BMS03327 Archived

04/12/2002 TSD0016 None Phasing out of Buried in Ground

(BIG) Streetlight Poles Current

17/09/2004 SA29

2.52

Minor Rd Estate Precast 4 Hole

Base Plate Foundation

Manufacturing Drwg

Superseded

2.53 Minor Rd Estate Precast

Foundation Installation Details Superseded

4/01/2006 SA46 None Changes in Inspection Current

Queensland Public Lighting

Construction Manual

Check this is the latest version before use 17 EX RED 00796 Ver 5

Joint Standard Document between Energex and Ergon Energy

Energex Limited ABN 40 078 849 055 Ergon Energy Corporation Limited ABN 50 087 646 062

Date Alert Drawings

Impacted Description

Amendment

Requirements for Buried in

Ground (BIG) Streetlight Poles

29/05/2006 SA29

2.54

Minor Rd 3 Bolt Streetlight

Column Precast Foundation

Manufacturing Drawing

Superseded

2.55

Minor Rd 3 Bolt Streetlight

Column Precast Foundation

Installation Details

Superseded

2.56

Minor Rd 4 Bolt Estate

Streetlight Column Precast

Foundation Manufacturing

Drawing

Superseded

2.57

Minor Rd 4 Bolt Estate

Streetlight Column Precast

Foundation Installation Details

Superseded

2.58

Major Rd 4 Bolt Streetlight

Column Precast Foundation

(Max Luminaire Mgt Ht 12.0m)

Manufacturing Drawing

Companion to New

Precast Foundation

Specification TS421D,

& is not in the New

Construction Manual

2.59

Major Rd 4 Bolt Streetlight

Column Precast Foundation

(Max Luminaire Mgt Ht 12.0m)

Installation Details

Superseded,

Redrafted to 1-2-842

26/09/2006 SA59

2.48 Major Road Bracket Fixing &

Luminaire Mounting Details

Moved to Design

Manual

2.49

Major / Minor Rd LV & 11kV

Arms Bracket & Luminaire

Mounting Details

Ditto

15/01/2007 SA74

2.9 (G)

Major Rd Slip Base Wiring

Details

Superseded,

Redrafted to 1-2-

831,& 1-5-5-9

2.28 (C) Major Rd Slip Base Cable

Clamp Install Details

Superseded,

Redrafted to 1-5-5-9

2.30 (C)

Replacement of 3 pin plug &

socket arrangement in existing

Slip Base Poles

Superseded

7.2 (E)

Major Road U/G Supply

BIG/BPM Poles with Single

Outreach Arm

Superseded,

Redrafted to 1-5

7.3 (E)

Major Road U/G Supply

BIG/BPM Poles with Double

Outreach Arm

Superseded,

Redrafted to 1-5

Queensland Public Lighting

Construction Manual

Check this is the latest version before use 18 EX RED 00796 Ver 5

Joint Standard Document between Energex and Ergon Energy

Energex Limited ABN 40 078 849 055 Ergon Energy Corporation Limited ABN 50 087 646 062

Date Alert Drawings

Impacted Description

Amendment

10.6 (F)

Major Road Slip Base Poles

U/G Supply from Pit

Superseded,

Redrafted to 1-2-

831,& 1-5-5-9

7.4 (B)

Major Road UG Supply

BIG/BPM Poles with Pedestrian

Floodlight on Single Outreach

Arm

Superseded,

Redrafted to 1-9-7

13.7 Type 7 Public Lighting Pole

Reinstatement Superseded

14.1

Luminaire Types Superseded, Moved

to new Assembly

Drawings

10/12/2008 SA121

-

Mounting Height Requirements

of Public Lighting Mains

Connection Box

None

2.27

Typical Unmetered Supply for

Rate 1 & Rate 2 Luminaires

General Arrangement

Superseded,

Redrafted to 1-4-12-1

4/08/2008 SA60 None

Introduction of Conduit Cable

Gland for Streetlight Mains Box

Superseded for new

constructions,

retained advice for

maintenance

purposes only

8/7/2010 TSD0118.1 Various

New Luminaires, Lamps & PE

Cells Contract 07075

Current, New stock

codes allocated,

redrafted to 1-2-806,

1-2-816, 1-2-841, 1-2-

843, 1-2-848, 1-2-

853, 1-2-870, 1-2-899

Queensland Public Lighting

Construction Manual

Check this is the latest version before use 19 EX RED 00796 Ver 5

Joint Standard Document between Energex and Ergon Energy

Energex Limited ABN 40 078 849 055 Ergon Energy Corporation Limited ABN 50 087 646 062

APPENDIX 3 – ENERGY QUEENSLAND PROCEDURE FOR REPORTING

A PROBLEM OR IMPROVEMENT WITH THE CONSTRUCTION

MANUALS

Purpose and scope

o To provide guidance for reporting a problem or improvement that has been identified within

the Queensland Public Lighting Construction Manual.

Communication Flow

o Peer Discussion

Any problem / improvement should be discussed with your peers in the first instance. This

will determine whether or not a simple solution is available.

o Construction Standards Feedback Form

Feedback Form, NA000303F100, should be initiated. This form should then be forwarded

to the Team Leader for comment.

o Team Leader Comment

Team Leaders should review any problems / improvements that are perceived by staff. If

they can resolve the issue, the feedback form with comments should be returned to the

originator.

c. The Team Leader should respond to this form within two weeks of receipt. If they

are unable to resolve the issue, the feedback form should be forwarded to the Work

Practices Co-ordinator for comment.

o Work Practices Co-ordinator Comment

The Work Practices Operational Forum should review the problem / improvement. If able

to be resolved through the forum, the Work Practices Co-ordinator should comment and

forward the feedback form back to the originator via the Team Leader.

d. The Work Practices Co-ordinator should respond to this form within two weeks of

receipt. If the issue is unable to be resolved, the coordinator should comment and forward

the form to the Asset Management Line Standards Group.

e.

f.

o Asset Safety & Performance Line Standards Group Review and Comment

The Asset Safety & Performance Line Standards Group will collate all problems /

improvements that have not been able to be resolved during an earlier phase in the

process. If the group considers that no action is required, an explanation of this decision

will be recorded on the feedback form and returned to the originator via the Work Practices

Co-ordinator and the Team Leader.

g. If the group decides that action is required, the relevant actions should be initiated.

This intended action should be recorded on the feedback form and returned to the

originator via the Work Practices Co-ordinator and the Team Leader. The Asset Safety &

Queensland Public Lighting

Construction Manual

Check this is the latest version before use 20 EX RED 00796 Ver 5

Joint Standard Document between Energex and Ergon Energy

Energex Limited ABN 40 078 849 055 Ergon Energy Corporation Limited ABN 50 087 646 062

Performance Line Standards Group should respond to this form within two weeks of

receipt.

Responsibilities

o Executive General Manager Asset Management is the Process Owner responsible for

approving this Reference document.

o Manager Engineering Line Design Standards is responsible for maintaining this Reference

document.

o Manager Engineering Line Design Standards is the Subject Matter Expert (SME) for the

content of this Reference document.

References

o NA000303F100. Construction Standards Feedback (Form)

Queensland Public Lighting

Construction Manual

Check this is the latest version before use 21 EX RED 00796 Ver 5

Joint Standard Document between Energex and Ergon Energy

Energex Limited ABN 40 078 849 055 Ergon Energy Corporation Limited ABN 50 087 646 062

RO

UT

E 1. Team Leader

2. Work Practices Co-ordinator Field Support

3. Asset Management Line Standards Group

All issues must be communicated on this form and followed up with an e-mail if required.

Work Practices Co-ordinator O/H or U/G Operational forum – [email protected]

Refer to the flow diagram on page 2 for the communication flow of this form.

Name of

originator Position

Region Depot /

Location Date

Construction

Manual

Drawing / Page

number

Description of problem / improvement

Remedy / suggestion

Team leader comments

Name Title Date

Work practices operational forum comments:

Name Title Date

Asset Management Line Standards Group’s comments

Name Title Date

Photographs or other supporting material may be attached if required.

Queensland Public Lighting

Construction Manual

Check this is the latest version before use 22 EX RED 00796 Ver 5

Joint Standard Document between Energex and Ergon Energy

Energex Limited ABN 40 078 849 055 Ergon Energy Corporation Limited ABN 50 087 646 062

Communication Flow

APPENDIX 4 – DRAWING CROSS REFERENCES

Originator Team Leader Work Practices Co-ordinator

Field Support

Asset Management

Line Standards Group

Reporting a Problem or Improvement with the Construction Manuals

1. Discuss Problem/

Improvement with

Peers

2. Is

further action

required?

4. Discuss with

Team Leader

Yes

3. Complete

NA000303F100

Construction

Standards Feedback

Form

9. Is

further action

required?

7. Is

further action

required?

5. Is

further action

required?

6. Standards and

Practices

Operational Forum

Yes

8. Review

Information

Yes

Yes

10. Update

Process

11. Form

Completed and

Returned to

Stakeholders

No

No NoNo

ASSEMBLIES

Index 1

Index 2

A

A

A

A

A

A

A

A

A

Index 1

A

A

A

PRACTICES

CONSTRUCTION

A

A

A

Index 4

Index 3

A

832

A

880

883

884

888

890

891

892

A893

A894

895 A

896 A

897

898 A

1-1-2-1

1 1 2-1 0E

LIGHTINGINTRODUCTION

AMENDMENT STATUS SHEET

10500-A4-1-1-2-1

NIL

NIL

A

A

A

A

A

A

A

800

801

802

803

804

805

806

807

808

809

810

811

812

813

814

815

816

817

818

821

822

823

824

825

826

827

828

829

830 A

831

833

834

835

836

837

838

839

840

841

842

843

844

845

846

847

848

849

851

852

853

854

855

856

858

863

864

865

867

870

872

873

874

875

876

887 A

899 A

B

A

A

A

A

A

A

A

A

A

A

A

PAGE / AMENDMENT PAGE / AMENDMENT

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

PAGE / AMENDMENT

SERVICES

1-3-2-1

1-3-3-1

1-3-4-1

1-3-5-1

1-3-6-1

1-3-6-2

1-3-6-3

1-3-7-1

1-3-8-1

1-3-9-1

1-3-9-2

1-3-10-1

1-3-11-1

1-3-11-2

1-3-12-1

1-3-12-2

1-3-12-3

1-3-13-1

1-3-13-2

1-3-14-1

1-3-14-2

1-3-15-1

1-3-15-2

1-3-16-1

1-3-17-1

Index 1

1-4-2-1

1-4-2-2

1-4-3-1

1-4-3-2

1-4-4-1

1-4-4-2

1-4-5-1

1-4-6-1

1-4-7-1

1-4-8-1

1-4-9-1

1-4-10-1

1-4-11-1

1-4-11-2

1-4-12-1

1-4-12-2

1-4-13-1

1-4-13-2

1-4-14-1

1-4-14-2

1-4-15-1

Index 1

Index 2

1-5-4-2

1-5-2-1

1-5-2-5

1-5-4-1

1-5-6-1

1-5-6-2

1-5-8-1

1-5-8-2

1-5-9-1

1-5-9-3

1-5-9-4

1-5-9-5

1-5-9-6

1-5-9-7

1-5-9-8

1-5-9-9

1-5-9-2

A

A

A

A

A

A

A

A1-5-14-3

1-5-13-1

1-5-14-2

1-5-17-2

1-5-18-2

1-5-19-1

1-5-19-2

1-5-10-1

1-5-10-2

1-5-11-1

1-5-11-2

1-5-13-2

1-5-14-1

1-5-17-1

1-5-18-1

PAGE / AMENDMENT

ROAD

COLUMNS MAJOR

1-4-2-3 A

B 22.03.13

D

E

E

E

D

B

D

B

B

E

E

C

D

C

C

D

C

C

E

C

B

B

D

900 A

901 A

902

903

D

B

C

D

A

B

B

B

B

A1-3-18-1

B1-3-2-2

D

B

B

B

D

B

B

A

B

B

B

B

D

D

E

C

C

C

C

B

VOLUME FOLDER ISSUEPAGE

Approved Ergon

Approved Energex

Checked

Drawn

Date

Date

Date

Date

A ORIGINAL ISSUE

HARD COPY UNCONTROLLED

C COPYRIGHT 2002 ENERGEX

ABN 50 087 646 062

Ergon Energy Corporation Limited

C COPYRIGHT 2002 ERGON ENERGY

ABN 40 078 849 055

ENERGEX Corporation Limited

ENERGEX or Ergon Energy

without written permission from

reproduced in part or whole

This document must not be

REFERENCE DRAWING ENERGEX

REFERENCE DRAWING ERGON

EE DRWG NO:

EGX DRWG NO:

C. Noel

F. Zaini

P. Relf / A. Bletchly

L. Burton / T. Borg

19/04/17

19/04/17

01/04/17

14/10/10

C 08.01.14

D

C

B

C

C

B

B

C

B

B

B

B

B

B

C

C

B

B

B

B

A

A

A

1-5-9-10

1-5-9-11

1-5-9-12

B

B

B

B

B

B

B

B

B

B

B

B

1-5-2-8

1-5-2-9

1-5-2-10

D

C

B

B

1-4-2-5 A

1-4-2-6 A

1-4-2-7 A

D 21.03.16

B

B

B

B

904 A

B

B

C

1-3-7-2

1-3-7-3

1-3-7-4

A

A

A

1-3-17-2 A

1-3-17-3 A

1-3-17-4 A

B

E 23.02.17

AIndex 5

B

B

B

B

B

B 905 A

906 A

907 A

908 A

909 A

910 A

911 A

1-3-2-3 A

B

A1-3-19-1

A1-3-19-2

A1-3-19-3

1-4-2-4 A

B

A1-4-16-1

A1-4-16-2

1-1-2-2

1 1 2-2 0E

LIGHTINGINTRODUCTION

AMENDMENT STATUS SHEET

10500-A4-1-1-2-2

NIL

NIL

Index 1

PAGE / AMENDMENT

ROAD

COLUMNS MINOR

1-6-2-1

1-6-2-2

1-6-3-1

1-6-3-2

1-6-4-1

1-6-4-2

1-6-5-1

1-6-5-2

1-6-6-1

1-6-6-2

1-6-7-1

1-6-7-2

Index 1

PAGE / AMENDMENT

1-7-2-1

1-7-2-2

1-7-2-3

1-7-3-1

1-7-3-2

1-7-4-1

1-7-4-2

1-7-5-1

1-7-5-2

1-7-6-1

1-7-6-2

1-7-7-1

1-7-7-2

1-7-8-1

MAJOR ROAD

POLE BRACKETS

A

1-7-9-1

1-7-9-2

1-7-8-2

Index 1

A

PAGE / AMENDMENT

1-8-2-1

1-8-2-2

1-8-2-3

1-8-3-1

1-8-3-2

1-8-4-1

1-8-4-2

1-8-5-1

1-8-5-2

MINOR ROAD

POLE BRACKETS

Index 1

A

A

PAGE / AMENDMENT

A

A

A

A

A

1-9-2-2

1-9-4-1

1-9-5-1

1-9-6-1

1-9-7-1

1-9-7-2

1-9-8-1

1-9-8-2

1-9-9-1

1-9-9-2

1-9-10-1

A

A

A1-9-11-1

1-9-11-2

Index 1

PAGE / AMENDMENT

1-10-3-2

1-10-3-3

FLOODLIGHTING

1-9-2-1

1-9-3-1

1-9-10-2

1-10-3-1

1-10-3-4

1-10-4-1

1-10-5-1

1-10-6-1

1-10-6-2

1-10-7-1

1-10-7-2

1-10-8-1

1-10-8-2

1-7-11-2

1-7-10-1

1-7-10-2

1-7-11-1

1-7-12-1

1-7-12-2

1-8-6-1

1-9-3-2

B 22.03.13

E

E

E

E

E

D

E

C

C

C

C

C

C

C

D

E

E

E

E

E

E

E

C

C

B

B

B

B

B

D

C

C

D

D

VOLUME FOLDER ISSUEPAGE

Approved Ergon

Approved Energex

Checked

Drawn

Date

Date

Date

Date

A ORIGINAL ISSUE

HARD COPY UNCONTROLLED

C COPYRIGHT 2002 ENERGEX

ABN 50 087 646 062

Ergon Energy Corporation Limited

C COPYRIGHT 2002 ERGON ENERGY

ABN 40 078 849 055

ENERGEX Corporation Limited

ENERGEX or Ergon Energy

without written permission from

reproduced in part or whole

This document must not be

REFERENCE DRAWING ENERGEX

REFERENCE DRAWING ERGON

EE DRWG NO:

EGX DRWG NO:

C. Noel

F. Zaini

P. Relf / A. Bletchly

L. Burton / T. Borg

19/04/17

19/04/17

01/04/17

14/10/10

C 08.01.14

B

B

B

B

B

B

B

B

B

B

B

B

B

B

B

B

B

B

B

A

B

B

A A

1-8-6-2 C

A

B

C

1-6-2-4

1-6-2-5

A

A

1-7-2-4

1-7-2-5

A1-8-2-4

1-8-2-5

B1-9-2-5

D 21.03.16

C

02.03.17E

A1-6-2-3

JOINT USE

B

B

B

B

B

B

B

B

1-10-2-1 A

1-10-9-1 A

1-6-2-6 A

1-1-2-3

1 1 2-3 0E

LIGHTINGINTRODUCTION

AMENDMENT STATUS SHEET

10500-A4-1-1-2-3

NIL

NIL

Index 1

PAGE / AMENDMENT

1-11-3-1

Index 1

A

PAGE / AMENDMENT

A

A

1-12-3-1

Index 1

A

PAGE / AMENDMENT

A

1-13-3-1

BULKHEAD LUMINAIRES

1-11-4-1

PE CELL CONVERSION

1-12-3-2

1-12-5-1

1-12-6-1

1-12-7-1

1-12-8-1

1-12-9-1

CONTROL WIRING

1-13-4-1

1-13-5-1

1-13-6-1

B 22.03.13

C

B

B

C B

B

B

VOLUME FOLDER ISSUEPAGE

Approved Ergon

Approved Energex

Checked

Drawn

Date

Date

Date

Date

A ORIGINAL ISSUE

HARD COPY UNCONTROLLED

C COPYRIGHT 2002 ENERGEX

ABN 50 087 646 062

Ergon Energy Corporation Limited

C COPYRIGHT 2002 ERGON ENERGY

ABN 40 078 849 055

ENERGEX Corporation Limited

ENERGEX or Ergon Energy

without written permission from

reproduced in part or whole

This document must not be

REFERENCE DRAWING ENERGEX

REFERENCE DRAWING ERGON

EE DRWG NO:

EGX DRWG NO:

C. Noel

F. Zaini

P. Relf / A. Bletchly

L. Burton / T. Borg

19/04/17

19/04/17

01/04/17

14/10/10

C 08.01.14

D 21.03.16

B

1-12-5-2 B

B

1-12-6-2 A

B

1-12-5-3 A

1-12-7-2 A

1-12-2-1 A

E 02.03.17

B

CONSTRUCTION SCHEDULE

Pole Pole Pole

Pit Pit Pit

Pad PadGMS Site

Tower

Pillar

(or)

Fiska Box

Tower

Pedestal

Tower

Comms Supply Cabinet

Normal Pillar

Link Pillar

Cross Road Pillar

Distribution Cabinet

Commercial / Industrial

Lid Pit

Pole Equipment

Pole Equipment

Bridge

Cross Arm

General Equipment

General Equipment General Equipment

General Equipment

Cross Arm

Aerial Stay

Stay

Guy

Guy

Aerial Stay

Stay

Generator

Energy Source

Energy Source

Distributed Generation

Power Station Generator

Earth Switch

HV Isolating Device

LV Isolating Device

TR Isolating Device

Isolating Equipment Installation

Isolating Equipment Installation

Isolating Equipment Installation

Isolating Equipment Installation

Earth

Switch

Switch

Switch

HV Spacer

LV Spacer

TR Spacer

Line Spacer

Line Spacer

Line Spacer

Line Spacer

Line Spacer

Line Spacer

Warning Device Marker Marker

Object Name

Ergon EO 4.3.4

Object Name

Ergon 3.3

Class

Construction

Dist. Generation System

CONSTRUCTION SCHEDULE

Step

Class

Construction

Object Name

Ergon EO 4.3.4

Object Name

Ergon 3.3

Transformer

3w Power Transformer Installation

(or)

Power Transformer Installation

Metering Unit

Voltage

SWER Isolator

Distribution

Current

Earthing

Load Control

Local Supply

Power

Regulator

Power

Reactor

Capacitor

Regulating Equipment Installation

Regulating Equipment Installation

Reactor

Capacitor

Substation Substation

Substation

Dist. Generation Site

Zone Substation Site

Substation

Substation

Substation (merged)

Composite Switch (RMUs)

Substation

Not in EO Model

Composite Switch

SWER Delimiter

Earth

Earth Cable Joint

HV Cable Joint

HV Cable Termination

LV Cable Joint

LV Cable Termination

TR Cable Joint

TR Cable Termination

Connector Point Installation

Connector Point Installation

Connector Point Installation

Connector Point Installation

Connector Point Installation

Connector Point Installation

Connector Point Installation

Connector Point Installation

Connector Point Installation

SWER Delimiter

Earth

Cable Joint

Cable Joint

Termination

Cable Joint

Cable Joint

Termination

Termination

Substation

Protection

Substation

Substation

Substation (merged)

Composite Switch (RMUs)

Substation

Not in EO Model

Composite Switch

Measuring Device

Fault Throw Switch

Surge Diverter

VOLUME FOLDER ISSUEPAGE

Approved Ergon

Approved Energex

Checked

Drawn

Date

Date

Date

Date

A ORIGINAL ISSUE

HARD COPY UNCONTROLLED

C COPYRIGHT 2002 ENERGEX

ABN 50 087 646 062

Ergon Energy Corporation Limited

C COPYRIGHT 2002 ERGON ENERGY

ABN 40 078 849 055

ENERGEX Corporation Limited

ENERGEX or Ergon Energy

without written permission from

reproduced in part or whole

This document must not be

REFERENCE DRAWING ENERGEX

REFERENCE DRAWING ERGON

EE DRWG NO:

EGX DRWG NO:

C. Noel

F. Zaini

P. Relf / A. Bletchly

L. Burton / T. Borg

19/04/17

19/04/17

01/04/17

02/02/17

1-1-3-1

1 1 3-1 0A

LIGHTINGINTRODUCTION - ERGON ENERGY ONLY

EO TERMINOLOGY CHANGES

10500-A4-1-1-3-1

NIL

NIL

Object Name

Ergon EO 4.3.4

Object Name

Ergon 3.3

Class

Construction

Class

Construction

Object Name

Ergon EO 4.3.4

Object Name

Ergon 3.3

COMMS LINE & CABLE SCHEDULE

Communications Cable

Communications Line

Communications Cable Communications Cable

Communications Line Communications Line

Object Name

Ergon EO 4.3.4

Object Name

Ergon 3.3

Class

Construction

CONDUIT DUCTING SCHEDULE

Duct Conduit Not visible in Schedule

Object Name

Ergon EO 4.3.4

Object Name

Ergon 3.3

Class

Construction

UNDERGROUND CABLE SCHEDULE

HV Cable

LV Cable

TR Cable

Earth Cable

Cable Segment

Cable Segment

Cable Segment

Cable Segment

Not visible in Schedule

Not visible in Schedule

Not visible in Schedule

Not visible in Schedule

COMMS CONSTRUCTION SCHEDULE

Communications Joint

Communications Pit

Communications Site

Communications Equip.

Communications Joint Communications Joint

Communications Pit Communications Pit

Communications Site Communications Site

Communications Equip. Communications Equip.

Class

Construction

Object Name

Ergon EO 4.3.4

Object Name

Ergon 3.3

PUBLIC LIGHT SCHEDULE

Streetlight Light Not visible in Schedule

Class

Construction

Object Name

Ergon EO 4.3.4

Object Name

Ergon 3.3

OVERHEAD CONDUCTOR SCHEDULE

HV Line

LV Line

TR Line

Aerial Earth Wire

Wire Segment

Wire Segment

Wire Segment

Wire Segment

Not visible in Schedule

Not visible in Schedule

Not visible in Schedule

Not visible in Schedule

VOLUME FOLDER ISSUEPAGE

Approved Ergon

Approved Energex

Checked

Drawn

Date

Date

Date

Date

A ORIGINAL ISSUE

HARD COPY UNCONTROLLED

C COPYRIGHT 2002 ENERGEX

ABN 50 087 646 062

Ergon Energy Corporation Limited

C COPYRIGHT 2002 ERGON ENERGY

ABN 40 078 849 055

ENERGEX Corporation Limited

ENERGEX or Ergon Energy

without written permission from

reproduced in part or whole

This document must not be

REFERENCE DRAWING ENERGEX

REFERENCE DRAWING ERGON

EE DRWG NO:

EGX DRWG NO:

C. Noel

F. Zaini

P. Relf / A. Bletchly

L. Burton / T. Borg

19/04/17

19/04/17

01/04/17

02/02/17

1-1-3-2

1 1 3-2 0A

LIGHTINGINTRODUCTION - ERGON ENERGY ONLY

EO TERMINOLOGY CHANGES

10500-A4-1-1-3-2

NIL

NIL