Upload
asad-abdul-munir
View
100
Download
3
Embed Size (px)
Citation preview
Universal Temperature Controller
Advanced ControlSimplicityNetworkingReliability
Copyright© 2009 Yokogawa Electric Corporation All Right ReservedJanuary 23rd, 2009
Training Pra Lomba PLC NasionalUB-Yokogawa Indonesia
Panitia E-PLC 2012
Universal Temperature Controller
Full
Con
trol
at
Your
Fin
gert
ips
Copyright© 2009 Yokogawa Electric Corporation All Right ReservedJanuary 23rd, 2009
2
Topik
۞ Pengenalan UT Advanced۞ Fitur Software UT Advaced۞ Pemrograman Ladder ۞ Monitoring
Digunakan untuk Lomba PLC UBSeijin Yokogawa Indonesia
Universal Temperature Controller
Full
Con
trol
at
Your
Fin
gert
ips
Copyright© 2009 Yokogawa Electric Corporation All Right ReservedJanuary 23rd, 2009
3
۞ Install PC software LL50A– (setup dan USB Driver)
Install software
USBUSB
Digunakan untuk Lomba PLC UBSeijin Yokogawa Indonesia
Universal Temperature Controller
Full
Con
trol
at
Your
Fin
gert
ips
Copyright© 2009 Yokogawa Electric Corporation All Right ReservedJanuary 23rd, 2009
General System - UT35A Controller
Digunakan untuk Lomba PLC UBSeijin Yokogawa Indonesia
4
X_DI1X_DI2 Y_AL1
Y_AL2
Y_AL3F1_KeyF2_KeyFn_Key
M01-M99
DAT01-DAT20
(256 Marker)
(28 Data Register)
P01-P10(10 P-Parameter)
input output
Controller
Universal Temperature Controller
Full
Con
trol
at
Your
Fin
gert
ips
Copyright© 2009 Yokogawa Electric Corporation All Right ReservedJanuary 23rd, 2009
Fitur-Fitur
۞ Timer (4 buah)۞ Counter (4 buah)۞ Aritmatika (add, E_add, sub, E_sub, mul, div, …)۞ Logika (and, or, xor, not, dll)۞ Transfer Data (mov, E_mov)۞ Pemrosesan Data (Bin, LLM, Min, Max, dll)۞ CLK (CLK1, CLK2, CLK10, CLK60)۞ PLS1 (always ON)۞ Input Diferensial (DIFU, DIFD)
5Digunakan untuk Lomba PLC UBSeijin Yokogawa Indonesia
Universal Temperature Controller
Full
Con
trol
at
Your
Fin
gert
ips
Copyright© 2009 Yokogawa Electric Corporation All Right ReservedJanuary 23rd, 2009
Basic Instruction (#1)
6
Universal Temperature Controller
Full
Con
trol
at
Your
Fin
gert
ips
Copyright© 2009 Yokogawa Electric Corporation All Right ReservedJanuary 23rd, 2009
Basic Instruction (#2)
7Digunakan untuk Lomba PLC UBSeijin Yokogawa Indonesia
Universal Temperature Controller
Full
Con
trol
at
Your
Fin
gert
ips
Copyright© 2009 Yokogawa Electric Corporation All Right ReservedJanuary 23rd, 2009
Operasi Aritmatika
8Digunakan untuk Lomba PLC UBSeijin Yokogawa Indonesia
Universal Temperature Controller
Full
Con
trol
at
Your
Fin
gert
ips
Copyright© 2009 Yokogawa Electric Corporation All Right ReservedJanuary 23rd, 2009
Comparison
9Digunakan untuk Lomba PLC UBSeijin Yokogawa Indonesia
Universal Temperature Controller
Full
Con
trol
at
Your
Fin
gert
ips
Copyright© 2009 Yokogawa Electric Corporation All Right ReservedJanuary 23rd, 2009
Komputasi logika
10
Universal Temperature Controller
Full
Con
trol
at
Your
Fin
gert
ips
Copyright© 2009 Yokogawa Electric Corporation All Right ReservedJanuary 23rd, 2009
11
Start LL50A
۞ Start LL50A – Start up LL50A and click “OK”
Digunakan untuk Lomba PLC UBSeijin Yokogawa Indonesia
Universal Temperature Controller
Full
Con
trol
at
Your
Fin
gert
ips
Copyright© 2009 Yokogawa Electric Corporation All Right ReservedJanuary 23rd, 2009
12
۞ Create new file– Select Use for “LADDER SEQUENCE FUNCTION” and click “OK”
Ladder Program
Digunakan untuk Lomba PLC UBSeijin Yokogawa Indonesia
Universal Temperature Controller
Full
Con
trol
at
Your
Fin
gert
ips
Copyright© 2009 Yokogawa Electric Corporation All Right ReservedJanuary 23rd, 2009
13
۞ One line ladder program– Select [Build Ladder Program] folder
Digunakan untuk Lomba PLC UBSeijin Yokogawa Indonesia
Universal Temperature Controller
Full
Con
trol
at
Your
Fin
gert
ips
Copyright© 2009 Yokogawa Electric Corporation All Right ReservedJanuary 23rd, 2009
UTAdvanced Pre-Release InformationInternal Use Only
14
۞ Click “Yes (Y)” and input program name
Ladder Program
Input name as “UTAdv”
Universal Temperature Controller
Full
Con
trol
at
Your
Fin
gert
ips
Copyright© 2009 Yokogawa Electric Corporation All Right ReservedJanuary 23rd, 2009
UTAdvanced Pre-Release InformationInternal Use Only
15
۞ One line ladder program– Select [User ladder calculation] tab (a)– Select and put “X_DI1”. Select and put “Y_AL1”
Ladder Program
(a)
Universal Temperature Controller
Full
Con
trol
at
Your
Fin
gert
ips
Copyright© 2009 Yokogawa Electric Corporation All Right ReservedJanuary 23rd, 2009
16
۞ Download ladder program to UTAdvanced– Select [Communication] [Download Ladder Program Data] in menu– Save the setting
Ladder Program
Digunakan untuk Lomba PLC UBSeijin Yokogawa Indonesia
Universal Temperature Controller
Full
Con
trol
at
Your
Fin
gert
ips
Copyright© 2009 Yokogawa Electric Corporation All Right ReservedJanuary 23rd, 2009
17
۞ Download ladder program to UTAdvanced– Select Communication port
1. For USB dedicated cable connection: Select serial port no.2. For Ethernet cable connection: Input “192.168.1.10”
– Click [Download Ladder Program Data] – After download complete, select [Windows] [Close all]
Ladder Program
Digunakan untuk Lomba PLC UBSeijin Yokogawa Indonesia
Universal Temperature Controller
Full
Con
trol
at
Your
Fin
gert
ips
Copyright© 2009 Yokogawa Electric Corporation All Right ReservedJanuary 23rd, 2009
18
۞ Download ladder program to UTAdvanced– Click [Download Ladder Program Data]
– After download complete, select [Windows] [Close all]
Ladder Program
Digunakan untuk Lomba PLC UBSeijin Yokogawa Indonesia
Universal Temperature Controller
Full
Con
trol
at
Your
Fin
gert
ips
Copyright© 2009 Yokogawa Electric Corporation All Right ReservedJanuary 23rd, 2009
UTAdvanced Pre-Release InformationInternal Use Only
19
۞ Monitoring ladder programming– Select [Communication] [Monitor Ladder program] in menu– Select [Monitor Ladder Program]
Ladder Program
Universal Temperature Controller
Full
Con
trol
at
Your
Fin
gert
ips
Copyright© 2009 Yokogawa Electric Corporation All Right ReservedJanuary 23rd, 2009
UTAdvanced Pre-Release InformationInternal Use Only
20
۞ Monitoring – Set simulator DI01 switch ON then monitor program
Set DI01 ON and check LED ON
Ladder Program
Simulator Be sure to turn LED SW ON, which is on the side of simulator
LED SW
Universal Temperature Controller
Full
Con
trol
at
Your
Fin
gert
ips
Copyright© 2009 Yokogawa Electric Corporation All Right ReservedJanuary 23rd, 2009
UTAdvanced Pre-Release InformationInternal Use Only
21
۞ Two lines ladder program– Open the One line ladder program setting (a)– Modify “one line ladder program” – Line 003: draw line, put and input “CLK1, TIM1, K01”– Line 004: Put as “TIM1”, put as “Y_AL2”
TIM
1 sec timer, timer#1, time out=K01
Ladder Program
Timer#1 time up?
(a)
Universal Temperature Controller
Full
Con
trol
at
Your
Fin
gert
ips
Copyright© 2009 Yokogawa Electric Corporation All Right ReservedJanuary 23rd, 2009
UTAdvanced Pre-Release InformationInternal Use Only
22
Ladder Program۞ Download ladder program to UTAdvanced
– Select [Communication] [Download Ladder Program Data] in menu– Click [Download Ladder Program Data]
– After download complete, select [Windows] [Close all]
Universal Temperature Controller
Full
Con
trol
at
Your
Fin
gert
ips
Copyright© 2009 Yokogawa Electric Corporation All Right ReservedJanuary 23rd, 2009
UTAdvanced Pre-Release InformationInternal Use Only
23
۞ Monitoring ladder programming– Select [Communication] [Monitor Ladder program] in menu– Select [Monitor Ladder Program]
Ladder Program
Universal Temperature Controller
Full
Con
trol
at
Your
Fin
gert
ips
Copyright© 2009 Yokogawa Electric Corporation All Right ReservedJanuary 23rd, 2009
UTAdvanced Pre-Release InformationInternal Use Only
24
۞ Monitoring– Set simulator DI01 switch ON then monitor program
Make sure D2 lamp ON after 5 sec
Ladder Program
Universal Temperature Controller
Full
Con
trol
at
Your
Fin
gert
ips
Copyright© 2009 Yokogawa Electric Corporation All Right ReservedJanuary 23rd, 2009
UTAdvanced Pre-Release InformationInternal Use Only
25
۞ Open Ladder program setting: Application– Select [File] [Open] in menu– Select the file “UTA_ladder_appli1.uta” from the USB memory
Ladder Program
Universal Temperature Controller
Full
Con
trol
at
Your
Fin
gert
ips
Copyright© 2009 Yokogawa Electric Corporation All Right ReservedJanuary 23rd, 2009
UTAdvanced Pre-Release InformationInternal Use Only
26
۞ Download Ladder program to UTAdvanced– Select [Communication] [Download All] in the menu– Click [Download Ladder Program Data]– After download complete, select [Windows] [Close all]– Monitor program
Ladder Program
Universal Temperature Controller
Full
Con
trol
at
Your
Fin
gert
ips
Copyright© 2009 Yokogawa Electric Corporation All Right ReservedJanuary 23rd, 2009
UTAdvanced Pre-Release InformationInternal Use Only
27
۞ Operation – When simulator’s DI01 is ON, control starts– When PV is over “K02” value(30), Timer will start (LED ON)– After 5 sec (Timer 1), the control stops (LED OFF)
Ladder Program
Universal Temperature Controller
Full
Con
trol
at
Your
Fin
gert
ips
Copyright© 2009 Yokogawa Electric Corporation All Right ReservedJanuary 23rd, 2009
UTAdvanced Pre-Release InformationInternal Use Only
28
۞ Operation – Set simulator’s DI01 ON to start – Change SP to more than 30
Check UTAdvanced STOP (LED ON)
Ladder Program
Universal Temperature Controller
Full
Con
trol
at
Your
Fin
gert
ips
Copyright© 2009 Yokogawa Electric Corporation All Right ReservedJanuary 23rd, 2009
UTAdvanced Pre-Release InformationInternal Use Only
29
۞ Detail view monitoring – Select [Monitor] [Detail view] in menu to see the detail value
If PV>SP (30) then Timer#1 starts
Ladder Program