CLMH RIM: 268.60 INV OUT: 265.18 CLDI RIM:278.37 INV IN (A): 276.84 INV IN (B): 276.79 INV IN (C): 276.17 INV IN (D): 270.73 INV OUT (E): 270.60 CL SDMH RIM: 269.77 INV IN 12": 262.47 INV IN 18": 262.20 INV OUT 24": 262.07 5" OAK 5" OAK DUGOUT DUGOUT BLEACHERS DUGOUT DUGOUT BLEACHERS SCOREBOARD 12" CMP 18" CMP 24" RCP 18" RCP 18" CMP 6" CPP 4" CPP 4" CPP (E) (A) (B) (C) (D) CLDI RIM:289.45 INV IN (A): 283.36 INV IN (B): 287.90 INV IN (C): 281.50 INV OUT (D): 277.00 (A) (B) (C) (D) 4" CPP 18" CMP 15" CMP POWER PANEL DIRT GRASS DIRT CL FIELD DRAIN NO INVERT INFO GRASS APPROX PROPERTY APPROX PROPERTY LINE BASEBALL FIELD BASEBALL FIELD SPIGOT IRRIGATION CONTROL VALVE (TYP.) IRRIGATION CONTROL VALVE (TYP.) T.B.M. RRS IN PP EL.=273.91 NAVD88 DATUM CONTROL POINT- 1 2" RB N:806812.99 E:1971571.78 EL.=276.26 KATHLEEN DRIVE CITY OF COLUMBIA MAINTAINED ROAD 3:1 279 277 275 273 117' 125' X X X X X X 5" OAK 5" OAK 5" OAK 5" OAK 5" OAK 5" OAK 5" OAK 5" OAK 5" OAK 5" OAK 5" OAK 5" OAK 5" OAK X X X X X X X X X X X X Concrete sidewalk provide max. 2% cross slope away from filed Relocate fence Relocate fence Remove portion of existing fence (50 lf) 5' Concrete sidewalk provide max. 2% cross slope away from field Landscape timber retaining wall Remove portion of existing fence (19 lf) Proposed press box see architectural drawings for dimensions Proposed press box see architectural drawings for dimensions 1 2 3 4 Press box layout Point # Northing Easting 1 806759.4296 1971286.9849 2 806768.2215 1971277.0443 Press box layout Point # Northing Easting 3 806421.3841 1971342.4765 4 806431.5416 1971333.9361 Install silt fence Install silt fence Install turf matting on slope Remove existing concrete Match existing concrete Remove portion of existing fence (109 lf) 35.6' 20' 11' 11' 20' 3' 5' 1% 1% 4" Perforated drain 4" Perforated drain to daylight on slope 4" Perforated drain to daylight on slope FIRE HYDRANT WATER VALVE POWER POLE & GUY OVERHEAD ELECTRIC DROP INLET (DI) INLET LEGEND LIGHT POLE SD STORM DRAIN PIPE GAS VALVE SANITARY SEWER MANHOLE CONCRETE SIDEWALK SANITARY SEWER LINE NATURAL GAS LINE UNDERGROUND TELEPHONE WATER LINE FENCE CONC. CURB & GUTTER ELEC BOX A/C / 2 X 2 PAD CLEANOUT (CO) JUNCTION BOX (JB) YARD INLET (YI) WATER METER WL TURF MATTING SILT FENCE The utilities are shown for the contractor's convenience only. There may be other utilities not shown on these Plans. The Engineer assumes no responsibility to verify the locations shown and it shall be the contractor's responsibility to verify the locations of all utilities within the limits of the work. All damage made to existing utilities by the contractor shall be the sole responsibility of the contractor. Call 811 Before You Dig Existing Fire Hydrant Existing Fire Hydrant THESE DOCUMENTS PROVIDED BY SGA|NARMOURWRIGHT DESIGN ARE SUBJECT TO THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT AS INTELLECTUAL PROPERTY. SIMILAR PROTECTION IS ALSO APPLICABLE TO ELECTRONIC INFORMATION IN ANY FORM. THE USE OF THESE DOCUMENTS OR THE ELECTRONIC INFORMATION THAT PRODUCED THEM IS PROHIBITED UNLESS OTHERWISE PROVIDED IN WRITING BY AND COMPENSATION TO THE ARCHITECT. PROJECT NUMBER: ISSUE DATE: 1 1815 S. Tryon St. Suite A Charlotte, NC 28203 p 704.332.5668 www.sganwdesign.com 2 3 4 5 A B C D DRAWN BY: CHECKED BY: COLUMBIA HIGH SCHOOL BASEBALL & SOFTBALL FIELD PRESSBOXES 1701 Westchester Dr, Columbia, SC 29210 C100 SITE ADAPTATION PLAN Project Status Revision Schedule # Description Date 11-16-2020 20-163-01 LEE Checker & LAND SURVEYORS CONSULTING ENGINEERS Chao & Associates, Inc. Civil - Structural - Survey 7 Clusters Court Columbia, SC 29210 Voice: (803) 772-8420 Fax: (803) 772-9120 Email: [email protected] 1. 3B. 12" 6" 3A. 2"-5" 4. 5. 3" 2. 1. Prepare soil before installing rolled erosion control products (RECP's), Including any necessary application of lime, fertilizer, and seed. Note: When using cell-o-seed do not seed prepared area. Cell-o-seed must be installed with paper side down. 2. Begin at the top of the slope by anchoring the RECP's In a 6" (15 cm) deep x 6" (15 cm) wide trench with approximately 12" (30cm) of RECP's Extended beyond the up-slope portion of the trench. Anchor the RECP's with a row of staples/stakes approximately 12" (30 cm) apart in the bottom of the trench. backfill and compact the trench after stapling. Apply seed to compacted soil and fold remaining 12" (30 cm) portion of RECP's back over seed and compacted soil. Secure RECP's over compacted soil with a row of staples/stakes spaced approximately 12" (30 cm) apart across the width of the RECP's. 3. Roll the RECP's (a.) down or (b.) horizontally across the slope. RECP's will unroll with appropriate side against the soil surface. all recp's must be securely fastened to soil surface by placing staples/stakes in appropriate locations as shown in the staple pattern guide. when using the dot system, staples/stakes should be placed through each of the colored dots corresponding to the appropriate staple pattern. 4. The edges of parallel RECP's must be stapled with approximately 2" - 5" (5 cm - 12.5 cm) overlap depending on RECP's type. 5. Consecutive RECP's spliced down the slope must be placed end over end (shingle style) with an approximate 3" (7.5 cm) overlap. Staple through overlapped area, approximately 12" (30 cm) apart across entire RECP's WIDTH. Note: *In loose soil conditions, the use of staple or stake lengths greater than 6" (15 cm) may be necessary to properly secure the RECP's. 6" Rolled Turf Reinforcement Matting Erosion Control Detail Not to scale Slope installation Maximum spacing = 6' V-Shaped Trench Detail Flat-Bottom Trench Detail Runoff Runoff Compacted earth Filter fabric Compacted earth Filter fabric Wire mesh Wire tie 12" OF FILTER FABRIC Wire mesh Wire tie 12" of filter fabric Fabric Attachment Detail 1.25 lb./linear ft. steel post Filter fabric 14 gage 6" x 6" wire mesh Heavy duty wire tie spaced 6" max. Use either flat-bottom or v-bottom trench shown below Backfill trench with compacted earth Fabric attachment see detail BURY FABRIC AND MESH 14 gage wire fence with 6" x 6" mesh Silt Fence Installation 1.25 lb./linear ft. steel post Wire tie Reinforced Silt Fence Construction Not to scale Note: Contractor shall remove sediment accumulated along the fence when it reaches 1/3 the height of the fence. Runoff 4" Sections 4' to 6' 1" Tooled edge 1 8 " rad. See plans for sidewalk width 1 8 " Place sealant in saw cut Sealant 1 2 " expansion material Tooled edge 1 8 " rad. Sidewalk Detail Not to Scale 1 4 " 1 4 " 1 4 " 1 8 " 1 2 " 1 4 " 50' max. between expansion joints Expansion joints Plan Dummy groove Contraction Joints Expansion Joint Edge See site plan for widths 4" X X X X X X X Typical Concrete Sidewalk Section Not to Scale 4" thick (min.), 3000 psi concrete slab WWF6X6-W2.1XW2.1 18" compacted subgrade compacted to 98% standard proctor Area of disturbance: 0.1 acres 1 Moved baseball pressbox 02/17/21 SECTION 36" ELEVATION Crushed stone Note: Max. trench depth not to exceed 24" - 36" below natural soil surface Grade Topsoil Geotextile 4" Perforated pipe 6" 5" 3" 4" Perforated Drain Detail Not toi Scale

Maximum spacing = 6' Runoff

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Maximum spacing = 6' Runoff

CLMHRIM: 268.60INV OUT: 265.18

CLDIRIM:278.37INV IN (A): 276.84INV IN (B): 276.79INV IN (C): 276.17INV IN (D): 270.73INV OUT (E): 270.60

CL SDMHRIM: 269.77

INV IN 12": 262.47INV IN 18": 262.20

INV OUT 24": 262.07

5" OAK

5" OAK

DU

GO

UT

DUGOUTBLEACHERS

DU

GO

UT

DUGOUTBLEACHERS

SCOREBOARD

12" C

MP

18" CMP

24" R

CP

18" R

CP

18" C

MP

6" C

PP4" C

PP

4" C

PP

(E)

(A)(B)

(C)

(D)

CLDIRIM:289.45INV IN (A): 283.36INV IN (B): 287.90INV IN (C): 281.50INV OUT (D): 277.00

(A)

(B)

(C)(D) 4" CPP

18" CMP

15" C

MP

POWER PANEL

DIRT

GRASS

DIRT

CL FIELD DRAINNO INVERT INFO

GRASS

APPROX PROPERTY LINEAPPROX PROPERTY LINE

BASEBALLFIELD

BASEBALLFIELD

SPIGOT

IRRIGATION CONTROLVALVE (TYP.)

IRRIGATION CONTROLVALVE (TYP.)

T.B.M. RRS IN PPEL.=273.91 NAVD88 DATUM

CONTROL POINT- 12" RBN:806812.99E:1971571.78EL.=276.26

KATHLEEN DRIVECITY OF COLUMBIA MAINTAINED ROAD

3:1

279

277

275273

117'

125'

X

X

X

X

X

X

5" O

AK

5" O

AK

5" O

AK

5" O

AK

5" O

AK

5" O

AK

5" O

AK

5" O

AK

5" O

AK

5" O

AK

5" O

AK

5" O

AK

5" O

AK

XX

X

X

X

X

X

XX

XX

X

Concrete sidewalkprovide max. 2% crossslope away from filed

Relocate fence

Relocate fence

Remove portion ofexisting fence (50 lf)

5' Concrete sidewalkprovide max. 2% crossslope away from field

Landscape timberretaining wall

Remove portion ofexisting fence (19 lf)

Proposed press boxsee architectural drawings

for dimensions

Proposed press boxsee architectural drawings

for dimensions

1

2

3

4

Press box layoutPoint # Northing Easting 1 806759.4296 1971286.9849 2 806768.2215 1971277.0443

Press box layoutPoint # Northing Easting 3 806421.3841 1971342.4765 4 806431.5416 1971333.9361

Install silt fence

Install silt fence

Install turf mattingon slope

Remove existingconcrete

Match existingconcrete

Remove portion ofexisting fence (109 lf)

35.6'

20'

11'

11'

20'

3'

5'

1%

1%

4" Perforated drain

4" Perforated drain todaylight on slope

4" Perforated drain todaylight on slope

FIRE HYDRANT

WATER VALVE

POWER POLE & GUY

OVERHEAD ELECTRIC

DROP INLET (DI)

INLET

LEGEND

LIGHT POLE

SD STORM DRAIN PIPE

GAS VALVESANITARY SEWERMANHOLE

CONCRETESIDEWALKSANITARY SEWER LINE

NATURAL GAS LINE

UNDERGROUNDTELEPHONE

WATER LINE

FENCE

CONC. CURB &GUTTER

ELEC BOX

A/C / 2 X 2 PAD

CLEANOUT (CO)

JUNCTION BOX (JB)

YARD INLET (YI)WATER METER

WL

TURF MATTING

SILT FENCE

The utilities are shown for the contractor's convenience only. There may be other utilitiesnot shown on these Plans. The Engineer assumes no responsibility to verify the locationsshown and it shall be the contractor's responsibility to verify the locations of all utilitieswithin the limits of the work. All damage made to existing utilities by the contractor shall bethe sole responsibility of the contractor.

Call 811 Before You Dig

Existing Fire Hydrant

Existing Fire Hydrant

THESE DOCUMENTS PROVIDED BY SGA|NARMOURWRIGHTDESIGN ARE SUBJECT TO THE ARCHITECTURAL WORKS

COPYRIGHT PROTECTION ACT AS INTELLECTUAL PROPERTY.SIMILAR PROTECTION IS ALSO APPLICABLE TO ELECTRONIC

INFORMATION IN ANY FORM. THE USE OF THESEDOCUMENTS OR THE ELECTRONIC INFORMATION THAT

PRODUCED THEM IS PROHIBITED UNLESS OTHERWISEPROVIDED IN WRITING BY AND COMPENSATION TO THE

ARCHITECT.

PROJECT NUMBER:

ISSUE DATE:

1

1815 S. Tryon St. Suite ACharlotte, NC 28203

p 704.332.5668www.sganwdesign.com

2 3 4 5

A

B

C

D

DRAWN BY:CHECKED BY:

CO

LUM

BIA

HIG

H SC

HOO

LBA

SEBA

LL &

SO

FTBA

LL F

IELD

PRES

SBO

XES

1701

Wes

tche

ster

Dr,

Col

umbi

a, S

C 2

9210

C100SITE ADAPTATION PLAN

Project StatusRevision Schedule

# Description Date

11-16-2020

20-163-01

LEEChecker

& LAND SURVEYORSCONSULTING ENGINEERS

Chao & Associates, Inc.Civil - Structural - Survey

7 Clusters CourtColumbia, SC 29210

Voice: (803) 772-8420Fax: (803) 772-9120

Email: [email protected]

1.

3B.

12"

6"

3A.

2"-5"

4.

5.

3"

2.

1. Prepare soil before installing rolled erosion control products (RECP's),Including any necessary application of lime, fertilizer, and seed.Note: When using cell-o-seed do not seed prepared area. Cell-o-seed must beinstalled with paper side down.

2. Begin at the top of the slope by anchoring the RECP's In a 6" (15 cm) deep x6" (15 cm) wide trench with approximately 12" (30cm) of RECP's Extendedbeyond the up-slope portion of the trench. Anchor the RECP's with a row ofstaples/stakes approximately 12" (30 cm) apart in the bottom of the trench.backfill and compact the trench after stapling. Apply seed to compacted soiland fold remaining 12" (30 cm) portion of RECP's back over seed andcompacted soil. Secure RECP's over compacted soil with a row ofstaples/stakes spaced approximately 12" (30 cm) apart across the width of theRECP's.

3. Roll the RECP's (a.) down or (b.) horizontally across the slope. RECP's willunroll with appropriate side against the soil surface. all recp's must besecurely fastened to soil surface by placing staples/stakes in appropriatelocations as shown in the staple pattern guide. when using the dot system,staples/stakes should be placed through each of the colored dotscorresponding to the appropriate staple pattern.

4. The edges of parallel RECP's must be stapled with approximately 2" - 5" (5 cm- 12.5 cm) overlap depending on RECP's type.

5. Consecutive RECP's spliced down the slope must be placed end over end(shingle style) with an approximate 3" (7.5 cm) overlap. Staple throughoverlapped area, approximately 12" (30 cm) apart across entire RECP'sWIDTH.Note: *In loose soil conditions, the use of staple or stake lengths greater than6" (15 cm) may be necessary to properly secure the RECP's.

6"

Rolled Turf Reinforcement MattingErosion Control Detail

Not to scale

Slope installation

Maximum spacing = 6'

V-Shaped Trench DetailFlat-Bottom Trench Detail

Runoff Runoff

Compacted earthFilter fabric

Compacted earthFilter fabric

Wire meshWire tie

12" OF FILTERFABRIC

Wire meshWire tie

12" of filter fabric

Fabric Attachment Detail

1.25 lb./linear ft. steel post

Filter fabric

14 gage6" x 6" wire mesh

Heavy duty wire tiespaced 6" max.

Use either flat-bottom orv-bottom trench shown below

Backfill trench withcompacted earth

Fabric attachmentsee detail

BURY FABRIC ANDMESH

14 gage wire fencewith 6" x 6" mesh

Silt Fence Installation

1.25 lb./linear ft.steel post

Wire tie

Reinforced Silt Fence ConstructionNot to scale

Note:Contractor shall remove sediment accumulated along the fence when itreaches 1/3 the height of the fence.

Runoff

4"

Sections

4' to 6'

1"

Tooled edge1

8" rad.

See plans forsidewalk width

18"

Place sealantin saw cut

Sealant

12" expansion

material

Tooled edge1

8" rad.

Sidewalk DetailNot to Scale

14"

1 4"

1 4"

18" 1

2"

1 4"

50' max. between expansion joints

Expansion joints

Plan

Dummy groove

Contraction Joints Expansion Joint Edge

See site plan for widths

4"

XXX XXX X

Typical Concrete Sidewalk SectionNot to Scale

4" thick (min.), 3000 psiconcrete slab

WWF6X6-W2.1XW2.118" compacted subgradecompacted to 98%standard proctor

Area of disturbance: 0.1 acres

1 Moved baseball pressbox 02/17/21

SECTION

36"

ELEVATIONCrushed

stone

Note: Max. trench depth not to exceed 24" - 36" belownatural soil surface

Grade

Topsoil

Geotextile

4"Perforated

pipe6"5"

3"4"

Perforated Drain DetailNot toi Scale

AutoCAD SHX Text
SCSP NORTH
AutoCAD SHX Text
MH
AutoCAD SHX Text
ICV
AutoCAD SHX Text
ICV
AutoCAD SHX Text
ICV
AutoCAD SHX Text
ICV
AutoCAD SHX Text
S
AutoCAD SHX Text
MH
AutoCAD SHX Text
Y
AutoCAD SHX Text
D
AutoCAD SHX Text
H
AutoCAD SHX Text
Y
AutoCAD SHX Text
D
AutoCAD SHX Text
H
AutoCAD SHX Text
WM
AutoCAD SHX Text
H
AutoCAD SHX Text
Y
AutoCAD SHX Text
D
AutoCAD SHX Text
WV
AutoCAD SHX Text
GV
AutoCAD SHX Text
S
AutoCAD SHX Text
1 inch = ft.
AutoCAD SHX Text
( IN FEET )
AutoCAD SHX Text
GRAPHIC SCALE
AutoCAD SHX Text
0
AutoCAD SHX Text
20
AutoCAD SHX Text
20
AutoCAD SHX Text
40
AutoCAD SHX Text
20
AutoCAD SHX Text
80
AutoCAD SHX Text
10
AutoCAD SHX Text
L
AutoCAD SHX Text
I
AutoCAD SHX Text
U
AutoCAD SHX Text
T
AutoCAD SHX Text
N
AutoCAD SHX Text
A
AutoCAD SHX Text
E
AutoCAD SHX Text
No. 21629
AutoCAD SHX Text
R
AutoCAD SHX Text
R
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
D
AutoCAD SHX Text
A
AutoCAD SHX Text
L
AutoCAD SHX Text
A
AutoCAD SHX Text
G
AutoCAD SHX Text
E
AutoCAD SHX Text
R
AutoCAD SHX Text
S
AutoCAD SHX Text
I
AutoCAD SHX Text
G
AutoCAD SHX Text
T
AutoCAD SHX Text
E
AutoCAD SHX Text
O
AutoCAD SHX Text
P
AutoCAD SHX Text
S
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
O
AutoCAD SHX Text
R
AutoCAD SHX Text
F
AutoCAD SHX Text
E
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
O
AutoCAD SHX Text
I
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
L
AutoCAD SHX Text
E
AutoCAD SHX Text
N
AutoCAD SHX Text
E
AutoCAD SHX Text
I
AutoCAD SHX Text
N
AutoCAD SHX Text
G
AutoCAD SHX Text
A
AutoCAD SHX Text
L
AutoCAD SHX Text
N
AutoCAD SHX Text
H
AutoCAD SHX Text
A
AutoCAD SHX Text
C
AutoCAD SHX Text
O
AutoCAD SHX Text
R
AutoCAD SHX Text
S
AutoCAD SHX Text
O
AutoCAD SHX Text
U
AutoCAD SHX Text
T
AutoCAD SHX Text
H
AutoCAD SHX Text
C
AutoCAD SHX Text
A
AutoCAD SHX Text
R
AutoCAD SHX Text
O
AutoCAD SHX Text
L
AutoCAD SHX Text
I
AutoCAD SHX Text
N
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
U
AutoCAD SHX Text
T
AutoCAD SHX Text
H
AutoCAD SHX Text
O
AutoCAD SHX Text
R
AutoCAD SHX Text
I
AutoCAD SHX Text
Z
AutoCAD SHX Text
A
AutoCAD SHX Text
F
AutoCAD SHX Text
O
AutoCAD SHX Text
E
AutoCAD SHX Text
T
AutoCAD SHX Text
A
AutoCAD SHX Text
C
AutoCAD SHX Text
I
AutoCAD SHX Text
F
AutoCAD SHX Text
T
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
C
AutoCAD SHX Text
I
AutoCAD SHX Text
N
AutoCAD SHX Text
O
AutoCAD SHX Text
I
AutoCAD SHX Text
T
AutoCAD SHX Text
CHAO &
AutoCAD SHX Text
ASSOCIATES
AutoCAD SHX Text
No. C00357
AutoCAD SHX Text
8"
AutoCAD SHX Text
4"
AutoCAD SHX Text
18" (MINIMUM)
AutoCAD SHX Text
18" (minimum)
AutoCAD SHX Text
8"
AutoCAD SHX Text
18" to 24"
AutoCAD SHX Text
18" to 24"
Page 2: Maximum spacing = 6' Runoff

8" 12' - 0" 8"

13' - 3"

8"

12

' -

0"

8"

13

' -

3"

13

' -

3"

EXISTING SIDEWALK TO REMAIN

EXISTING BACK-STOP FENCING

NOTE:

• BASE BID - REMOVE & REINSTALL EXISTING BACK STOP FENCING

• ALTERNATE #1 - PROVIDE NEW BACKSTOP FENCING, SEE ALTERNATE #1 FENCING

DETAILS

144 SF

STORAGE

8"

7' -

11

"3

' -

4"

1' -

4"

B1

A251

B3

A251

D1

A251

D3

A251

8" 12' - 0" 8"

13' - 3"

D3

A301

F.E.S.

E-01

A303

4

A303

7

1' - 6" 1' - 6"

D.S.D.S.

CONC. SPLASH BLOCKCONC. SPLASH BLOCK

A2012

A201

A201

A201

1

4

TH

RO

UG

H W

ALL U

NIT

3

NEW SHIPS LADDER TO PRESSBOX, MNFR. TO PROVIDE LANDING@ TOP OF STAIR AS REQ'D PER STAIR DESIGN

HORIZONTAL GUARD RAILS WITH 3X3 POSTS, 42" HIGH, SEE TYP. DTL. A303

PLASTIC LAMINATE COVERED COUNTER

8" 2' - 4" 7' - 4" 2' - 4" 8"

13' - 3"

13

' -

3"

B1

A251

8"

4' -

10

"3

' -

6"

3' -

8"

8"

8" 4' - 2" 7' - 10" 8"

8"

5' -

9"

6' -

3"

8"

13

' -

3"

13' - 3"

97 SF

PRESS BOX

B3

A251

D1

A251

D3

A251

D3

A301

NEW 3'-0" SAFETY GATE AT SLABEDGE TO STAIR

A302

3

W1

D.S.D.S.

D1

A251

7"

/ 1

2"

7"

/ 1

2"

7" / 12"

7" / 12"

7"

/ 1

2"

7"

/ 1

2"

7" / 12"

7" / 12"

NEW STANDING SEAM METAL ROOFINGSLOPE 7:12, COLOR TO MATCH EXISTING SCHOOL, VERIFY COLOR BY ARCH./OWNER

PRE FIN. ALUMINUM GUTTER W/ DOWNSPOUTS,COLOR TO MATCH ROOFING

BUILDING PLAN GENERAL NOTES:1. DO NOT SCALE OFF DRAWINGS; DIMENSIONS IN QUESTION SHALL BE CLARIFIED BY ARCHITECT.

2. ALL EXTERIOR DIMENSIONS ARE SHOWN TO THE OUTSIDE FACE OF MASONRY UNITS.

3. ALL INTERIOR DIMENSIONS ARE SHOWN TO THE FACE OF MASONRY UNITS.

4. ALL DOORS SHALL BE 8" MIN. OFF NEAREST CORNER OR CENTERED ON WALL UNO.

5. ALL FINISH AND COLOR SELECTIONS SHALL BE APPROVED BY OWNER AND/OR ARCHITECT. SEE DRAWINGS FOR SPECIFIED FINISHES.

6. WHERE ENLARGED PLANS ARE INDICATED, SEE ENLARGED PLAN SHEETS FOR WALL TYPES, DIMENSIONS AND OTHER DETAIL INFORMATION IN THOSE AREAS.

7. REFER TO SHEET CIVIL SHEET FOR OVERALL SITE PLAN OF PROPOSED WORK AREAS.

8. NOTE: THRU WALL HVAC UNIT SHALL BE "AMANA: PTHO73G" OR APPROVED EQUAL. PROVIDE WALL FLASHINGS BY MANUFACTUR

9. INSTALL FIRE EXTINGUISHER WITH STRAPS A GROUND FLOOR AS SHOWN. SEE SHEET A303 FOR TYPE.

10. PAINT INTERIOR OF PRESS BOX AREAS BOTH GROUND FLOOR AND PRESS BOX LEVEL. COLOR BY OWNER, SEE SHEET A303

11. COLOR OF SPLIT FACE BLOCK VENEER TO BE SELECTED BY OWNER AND/OR ARCHITECT. COLOR TO MATCH EXISTING AHTLETIC BUILDING COLORS/CONDITIONS.

12. INSTALL NEW ALTERNATING TREAD STAIR BY PARAGON STAIRS OR APPROVED EQUAL VIA SHOP DRAWING

13. INSTALL PRE FABRICATED GAURD RAILING AT PRESS BOX LEVEL, SEE SHEET A303

14. PAINT GYP. BOARD CEILING, SEE SHEET A303

15. PRVIDE (5) 2" DIA. GROMET HOLES EQUALLY SPACES AT PRESS BOX COUNTER/DESK.

THESE DOCUMENTS PROVIDED BY SGA|NARMOURWRIGHT

DESIGN ARE SUBJECT TO THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT AS INTELLECTUAL PROPERTY.

SIMILAR PROTECTION IS ALSO APPLICABLE TO ELECTRONIC

INFORMATION IN ANY FORM. THE USE OF THESE DOCUMENTS OR THE ELECTRONIC INFORMATION THAT

PRODUCED THEM IS PROHIBITED UNLESS OTHERWISE

PROVIDED IN WRITING BY AND COMPENSATION TO THE ARCHITECT.

PROJECT NUMBER:

ISSUE DATE:

1

1815 S. Tryon St. Suite A

Charlotte, NC 28203

p 704.332.5668

www.sganwdesign.com

2 3 4 5

A

B

C

D

DRAWN BY:

CHECKED BY:

CO

LU

MB

IA H

IGH

SC

HO

OL

BA

SEB

ALL &

SO

FTB

ALL F

IELD

PR

ESSB

OX

ES

17

01

We

stc

he

ste

r D

r, C

olu

mb

ia, SC

29

21

0

11/16/2020

20-163-01

A101

FLOOR PLANS

Author

CONSTRUCTIONDOCUMENTS

Checker

3/8" = 1'-0"1

FIRST FLOOR

3/8" = 1'-0"2

PRESS BOX

3/8" = 1'-0"3

ROOF PLAN

Revision Schedule

# Description Date

1 ADDENDUM #3 3/24/21

1

1

1

Page 3: Maximum spacing = 6' Runoff

FIRST FLOOR0' - 0"

T.O.M.20' - 0"

PRESS BOX12' - 0"

SPLIT FACE BLOCK COLOR #1COLOR TO MATCH EXISTING

SPLIT FACE BLOCK COLOR #2COLOR TO MATCH EXISTING

SPLIT FACE BLOCK COLOR #1COLOR TO MATCH EXISTING

NEW STANDING SEAM METAL ROOFINGTO MATCH EXISTING, OVER 5/8" ROOF SHEATHING, 30# ROOFING FELT

NEW 24" P.L. COUNTER TOP

1' -

4"

14

' -

0"

4' -

8"

1' -

4"

1' -

0"

T.O.F.-1' - 4"

4' - 0"

8' - 0"

11' - 4"

14' - 8"

19' - 4"

LIGHT GAUGE METAL ROOF TRUSSES, 4" MIN TOP & BOTTOM CHORD

NEW PEFORATED VENTED SOFFIT

NEW 1X FRIEZE BOARD WITH MATCHING TRIM, COLOR TO MATCH ROOFING

8" x 8" x 16" BOND BEAM W/ (2) #5'S TYP. @ ALL BOND BEAMS

POURED CONC. FLOOR OVER METAL DECKING & FLOOR JOISTS

2' - 8"

TOP OF FOOTING MIN. 16" BELOW GRADE

CMU BOND BEAM TYP W/ (2) #5'S CONTIN. BOND BEAM TO WRAP AROUND STRUCTURE TYP.

PROVIDE 8" CMU BLOCK F.F.E TO TOP OF FOOTING, GROUT CELLS SOLID

CONTRACTOR TO COMPACT SOIL TO 2,000 PSF MIN. SOIL BEARING CAPACITY

CONC. FOOTING W/ (3) #5'S CONTIN. & #4'S TRANSVERSE @ 16" O.C.

7" / 12"

A302

B3Sim

4" MIN. CONC w/ 6x6x21.x2.1 SLAB OVER VAPOR BARRIER &

4" SAND/GRAVEL BASENEW SIDEWALK, SEE CIVIL

NOTE: VERTICAL WALL REINFORCING - #5'S @ 32” MAXIMUM CENTERS W/ #5 DOWELS TO MATCH AT THE FOUNDATION. THE CMU CELLS WHERE THE REINFORCING OCCURS ARE TO BE FILLED SOLID WITH 3000 PSI PEA GRAVEL GROUT FROM FOUNDATION TO TOP OF WALL., TYP. @ ALL WALLS LOCATIONS

FIRST FLOOR0' - 0"

T.O.M.20' - 0"

PRESS BOX12' - 0"

SPLIT FACE BLOCK COLOR #1SEE ELEVATIONS

SPLIT FACE BLOCK COLOR #2SEE ELEVATIONS

SPLIT FACE BLOCK COLOR #1SEE ELEVATIONS

8" MIN CAST ALUMINUM LETTERS, 1" THICK ATTACHED TO FACE OF SPLIT

FACE BLOCK WALL

NEW ALUM & GLASS STOREFRONT WINDOW

NEW STANDING SEAM METAL ROOFING TO MATCH EXISTING, OVER 5/8" ROOF

SHEATHING, 30# ROOFING FELT

NEW 24" P.L. COUNTER TOP

1' -

4"

14

' -

0"

4' -

8"

8" x 8" x 16" BOND BEAM

T.O.F.-1' - 4"

7" / 12"

LIGHT GAUGE METAL ROOF TRUSSES, 4" MIN TOP & BOTTOM CHORD

NEW PEFORATED VENTED SOFFIT

NEW 1X FRIEZE BOARD WITH MATCHINGTRIM, COLOR TO MATCH ROOFING

2' -

6"

2"

4' -

0"

1' -

4"

8' -

0"

12

' -

0"

POURED CONC. FLOOR OVER METAL DECKING & FLOOR JOISTS

4' - 0"

8' - 0"

11' - 4"

14' - 8"

19' - 4"

CMU BOND BEAM TYP W/ (2) #5'S CONTIN.BOND BEAM TO WRAP AROUND

STRUCTURE TYP

A302

B1

1' -

4"

1' -

0"

2' - 8"

CONC. FOOTING W/ (3) #5'S CONTIN. & #4'S TRANSVERSE @ 16" O.C.

CONTRACTOR TO COMPACT SOIL TO 2,000 PSF MIN. SOIL BEARING CAPCITY

PROVIDE 8" CMU BLOCK F.F.E TO TOP OF FOOTING, GROUT CELLS SOLID

TOP OF FOOTING MIN. 16" BELOW GRADE

3,000 PSI 4" CONC SLAB, 6x6x2.1x2.1, OVER VAPOR BARRIER & 4" SAND/GRAVEL BASE,TYPICAL

PROVIDE 1/2" MIN. EXPANSION JOINT MATERIAL AT PERIMITER OF SLAB EDGE

A302

1

NOTE: VERTICAL WALL REINFORCING - #5'S @ 32” MAXIMUM CENTERS W/ #5 DOWELS TO MATCH

AT THE FOUNDATION. THE CMU CELLS WHERE THE REINFORCING OCCURS ARE TO BE FILLED

SOLID WITH 3000 PSI PEA GRAVEL GROUT FROM FOUNDATION TO TOP OF WALL., TYP. @ ALL

WALLS LOCATIONS

FIRST FLOOR0' - 0"

T.O.M.20' - 0"

PRESS BOX12' - 0"

B1

A251

T.O.F.-1' - 4"

SPLIT FACE BLOCK COLOR #1SEE ELEVATIONS

SPLIT FACE BLOCK COLOR #2SEE ELEVATIONS

SPLIT FACE BLOCK COLOR #1SEE ELEVATIONS

STANDING SEAM METAL ROOFING TO MATCH EXISTING, OVER 5/8" ROOF SHEATHING, 30#

ROOFING FELT

8" x 8" x 16" BOND BEAM

LIGHT GAUGE METAL ROOF TRUSSES, 4" MIN TOP & BOTTOM CHORD

PEFORATED VENTED SOFFIT

1X FRIEZE BOARD WITH MATCHINGTRIM, COLOR TO MATCH ROOFING

POURED CONC. FLOOR OVER METAL DECKING & FLOOR JOISTS

CONC. FOOTING W/ (3) #5'S CONTIN. & #4'S TRANSVERSE @ 16" O.C.

CONTRACTOR TO COMPACT SOIL TO 2,000 PSF MIN. SOIL BEARING CAPCITY

PROVIDE 8" CMU BLOCK F.F.E TO TOP OF FOOTING, GROUT CELLS SOLID

3,000 PSI CONC SLAB

PROVIDE 1/2" MIN. EXPANSION JOINT MATERIAL AT PERIMETER

OF SLAB EDGE

CMU BOND BEAM TYP W/ (2) #5'S CONTIN.BOND BEAM TO WRAP AROUND

STRUCTURE TYP

PRE FAB SPIRAL STAIR

GAURD ACCESS GATE TO ENTRY STAIR

14' - 8"

11' - 4"

8' - 0"

1' -

4"

14

' -

0"

4' -

8"

7" / 12"

A302

B3Sim

2' - 8"

1' -

0"

2' - 0"

1' -

0"

2' X 2' X 1' COLUMN FOOTINGFOR PRE FABRICATED SPIRAL STAIR

NOTE: VERTICAL WALL REINFORCING - #5'S @ 32” MAXIMUM CENTERS W/ #5 DOWELS TO MATCH

AT THE FOUNDATION. THE CMU CELLS WHERE THE REINFORCING OCCURS ARE TO BE FILLED

SOLID WITH 3000 PSI PEA GRAVEL GROUT FROM FOUNDATION TO TOP OF WALL., TYP. @ ALL

WALLS LOCATIONS

THESE DOCUMENTS PROVIDED BY SGA|NARMOURWRIGHT

DESIGN ARE SUBJECT TO THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT AS INTELLECTUAL PROPERTY.

SIMILAR PROTECTION IS ALSO APPLICABLE TO ELECTRONIC

INFORMATION IN ANY FORM. THE USE OF THESE DOCUMENTS OR THE ELECTRONIC INFORMATION THAT

PRODUCED THEM IS PROHIBITED UNLESS OTHERWISE

PROVIDED IN WRITING BY AND COMPENSATION TO THE ARCHITECT.

PROJECT NUMBER:

ISSUE DATE:

1

1815 S. Tryon St. Suite A

Charlotte, NC 28203

p 704.332.5668

www.sganwdesign.com

2 3 4 5

A

B

C

D

DRAWN BY:

CHECKED BY:

CO

LU

MB

IA H

IGH

SC

HO

OL

BA

SEB

ALL &

SO

FTB

ALL F

IELD

PR

ESSB

OX

ES

17

01

We

stc

he

ste

r D

r, C

olu

mb

ia, SC

29

21

0

11/16/2020

20-163-01

A301

WALL SECTIONS

CC

CONSTRUCTIONDOCUMENTS

KK/CC

3/4" = 1'-0"D1

TYP WALL SECTION3/4" = 1'-0"

D2TYP WALL SECTION @ WINDOW

3/4" = 1'-0"D3

TYPICAL SECTION @ LADDER

Revision Schedule

# Description Date

1 ADDENDUM #3 3/24/21

1

1

1

Page 4: Maximum spacing = 6' Runoff

THESE DOCUMENTS PROVIDED BY SGA|NARMOURWRIGHT

DESIGN ARE SUBJECT TO THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT AS INTELLECTUAL PROPERTY.

SIMILAR PROTECTION IS ALSO APPLICABLE TO ELECTRONIC

INFORMATION IN ANY FORM. THE USE OF THESE DOCUMENTS OR THE ELECTRONIC INFORMATION THAT

PRODUCED THEM IS PROHIBITED UNLESS OTHERWISE

PROVIDED IN WRITING BY AND COMPENSATION TO THE ARCHITECT.

PROJECT NUMBER:

ISSUE DATE:

1

1815 S. Tryon St. Suite A

Charlotte, NC 28203

p 704.332.5668

www.sganwdesign.com

2 3 4 5

A

B

C

D

DRAWN BY:

CHECKED BY:

CO

LU

MB

IA H

IGH

SC

HO

OL

BA

SEB

ALL &

SO

FTB

ALL F

IELD

PR

ESSB

OX

ES

17

01

We

stc

he

ste

r D

r, C

olu

mb

ia, SC

29

21

0

11/16/2020

20-163-01

A401

ALTERNATE #1BACKSTOP DETAILS

Author

CONSTRUCTIONDOCUMENTS

Checker

Revision Schedule

# Description Date

1 ADDENDUM #3 3/24/21

3/32" = 1'-0"1

ALT. #1 FENCING DETAILS

1

Page 5: Maximum spacing = 6' Runoff

SECTION 05 7113 - FABRICATED METAL SPIRAL STAIRS

FABRICATED METAL SPIRAL STAIRS

05 7113 - 1SGA|NW Design

SECTION 05 7113 - FABRICATED METAL SPIRAL STAIRS

PART 1 - GENERAL

1.1 SUMMARY

A. Section includes fabricated metal spiral stairs with steel central-supporting columns, radiating treads, and railings.

1.2 ACTION SUBMITTALS

A. Product Data: For fabricated metal spiral stairs, including railings.

B. Shop Drawings: For fabricated metal spiral stairs and railings. Include plans, elevations, sections, details, attachments to other work, and field measurements.

C. Delegated-Design Submittal: For fabricated metal spiral stairs and railings, including analysis data signed and sealed by the qualified professional engineer responsible for their preparation.

PART 2 - PRODUCTS

2.1 MANUFACTURERS

A. Manufacturers: Subject to compliance with requirements, provide products by one of the following:

1. Accent Stairs; ADPG, LLC.2. Boston Stair, LLC.3. Custom Iron Inc.4. Iron Shop (The).5. Paragon Stairs.6. Salter Spiral Stair.7. Spiral Stairs of America.8. Stairways Inc.

2.2 PERFORMANCE REQUIREMENTS

A. Delegated Design: Engage a qualified professional engineer, to design fabricated metal spiral stairs and railings.

B. Structural Performance of Stairs: Fabricated metal spiral stairs shall withstand the effects of gravity loads and the following loads and stresses within limits and under conditions indicated in accordance with ASCE/SEI 7 :

1. Uniform and concentrated loads need not be assumed to act concurrently.2. Railing Loads: Stairs shall withstand stresses resulting from railing loads.3. Deflection: Limit deflection of treads, landings, and framing members .

Page 6: Maximum spacing = 6' Runoff

SECTION 05 7113 - FABRICATED METAL SPIRAL STAIRS

FABRICATED METAL SPIRAL STAIRS

05 7113 - 2SGA|NW Design

C. Structural Performance of Railings: Railings shall withstand the effects of gravity loads and the following loads and stresses within limits and under typical conditions.

1. Handrails:a. Uniform load of 50 lbf/ft. applied in any direction.b. Concentrated load of 200 lbf applied in any direction.c. Uniform and concentrated loads need not be assumed to act concurrently.

2. Infill of Guards:a. Concentrated load of 50 lbf applied horizontally on an area of 1 sq. ft..b. Infill load and other loads need not be assumed to act concurrently.

2.3 SPIRAL STAIRS

A. Center Column: Steel [or] pipe welded to baseplate for anchorage to floor structure. Brace column at upper floors by means of landings attached to column and floor structure unless otherwise indicated. Provide cap for column if top is exposed.

B. Treads and platforms, Formed Metal Plate: Formed steel plate, welded to hubs or center column, and as follows:

1. Straight flanges and welded-on legs.2. Rolled-steel, floor-plate wearing surfaces.3. Smooth steel-plate wearing surfaces.

C. Treads and Platforms, Metal Framed: Steel framed, welded to hubs or center column, and without legs; wearing surface as follows:

1. Smooth steel plate with integral abrasive.

D. Railings: Uniformly bent to spiral shape. Extend to top guard rail as shown on drawings. Extend at bottom of stair as required.

2.4 MATERIALS

A. Metal Surfaces, General: Provide materials with smooth surfaces, without seam marks, roller marks, rolled trade names, stains, discolorations, or blemishes.

B. Brackets, Flanges, and Anchors: Same metal and finish as supported item unless otherwise indicated.

C. Steel Plates, Shapes, and Bars: ASTM A36/A36M.

D. Rolled-Steel Floor Plate: ASTM A786/A786M, rolled from plate complying with ASTM A36/A36M or ASTM A283/A283M, Grade C or Grade D.

E. Steel Pipe Columns: ASTM A53/A53M, Schedule 40. Provide Schedule 80 for columns larger than where required to support loads.

F. Steel Pipe: ASTM A53/A53M, Standard Weight (Schedule 40) unless otherwise indicated.

G. Steel Tubing: Either cold-formed steel tubing complying with ASTM A500/A500M or mandrel-drawn mechanical tubing complying with ASTM A513, Type 5.

Page 7: Maximum spacing = 6' Runoff

SECTION 05 7113 - FABRICATED METAL SPIRAL STAIRS

FABRICATED METAL SPIRAL STAIRS

05 7113 - 3SGA|NW Design

H. Aluminum Sheet and Plate: ASTM B209, Alloy 6061-T6.

I. Aluminum-Alloy Rolled Tread Plate: ASTM B632/B632M, Alloy 6061-T6.

J. Aluminum Pipe and Structural Round Tubing: ASTM B429/B429M, Alloy 6063-T6.

K. Extruded-Aluminum Tubing: ASTM B221, Alloy 6063-T5/T52.

2.5 MISCELLANEOUS MATERIALS

A. Fasteners: For connecting stair components and for anchoring stairs to other construction, select fasteners of type, grade, and class required to produce connections capable of withstanding design loadings.

1. For steel and cast iron, use plated steel fasteners complying with ASTM B633, Class Fe/Zn 25 for electrodeposited zinc coating.

B. Shop Primer for Ferrous Metal: Fast-curing, lead- and chromate-free, universal modified-alkyd primer complying with MPI#79 and compatible with finish paint systems indicated.

C. Wood for Stair Treads, Handrails, and Platforms: Laminated red oak, sanded to 120-grit smoothness. Apply uniform coat of manufacturer's standard clear sealer.

D. Rubber Wearing Surfaces: Manufacturer's standard, 1/4-inch- thick, molded-rubber covering in pattern and color indicated or, if not indicated, as selected by Architect from manufacturer's standard colors and patterns.

2.6 FABRICATION

A. Welded Connections: Cope components at connections to provide close fit, or use fittings designed for this purpose. Weld all around at connections, including at fittings.

1. Use materials and methods that minimize distortion and develop strength and corrosion resistance of base metals.

2. Finish exposed surfaces smooth and blended and, except for fillet welds, so welded surface matches contours of adjoining surfaces.

2.7 STEEL AND IRON FINISHES

A. Preparation for Shop Priming: Prepare uncoated ferrous-metal

B. Apply shop primer to prepared surfaces of handrails and railing components unless otherwise indicated. Comply with requirements in SSPC-PA 1, "Paint Application Specification No. 1: Shop, Field, and Maintenance Painting of Steel," for shop painting.

Page 8: Maximum spacing = 6' Runoff

SECTION 05 7113 - FABRICATED METAL SPIRAL STAIRS

FABRICATED METAL SPIRAL STAIRS

05 7113 - 4SGA|NW Design

PART 3 - EXECUTION

3.1 INSTALLATION

A. Fastening to In-Place Construction: Provide anchorage devices and fasteners where needed for securing fabricated metal spiral stairs to in-place construction; include threaded fasteners for concrete and masonry inserts, through bolts, lag bolts, wood screws, and other connectors as required.

B. Install fabricated metal spiral stairs accurately in location, alignment, and elevation; level and plumb; and in accordance with manufacturer's written instructions.

C. Field measure existing conditions before fabrication of shop drawing and/or installation of spiral stair at site location.

D. Field Welding:

1. Use materials and methods that minimize distortion and develop strength and corrosion resistance of base metals.

2. At exposed connections, finish exposed welds and surfaces smooth and blended so no roughness shows after finishing and welded surface matches contours of adjoining surfaces.

3.2 REPAIR

A. Touchup Painting: Immediately after erection, clean field welds, bolted connections, and abraded areas of shop paint and paint exposed areas with same material.

B. For galvanized surfaces, clean field welds, bolted connections, and abraded areas and repair galvanizing in accordance with ASTM A780/A780M.

1. Paint repaired areas with same material used for shop painting.

3.3 PROTECTION

A. Protect finished tread surfaces during construction by covering with 1/2-inch- thick, plywood secured with plastic strapping or another nonmarring fastening method.

END OF SECTION 05 7113