  • 7/30/2019 Metris Compressed Air Brochure UK

    1/6

    Innovation forcost reduction

    in pneumatics.Leakage monitoring.Measurement ofcompressed air consumption.

    Measuremen

    tofcompressedairconsumption

    www.if

    m-e

    lectronic.c

    om

    /metris

    R

  • 7/30/2019 Metris Compressed Air Brochure UK

    2/6

    MODE/ENTER SET

    Decentralised monitoring, measurementand display of compressed air consumption.

    Many sources,

    including the cam-

    paign efficient

    compressed air*

    clearly indicate the

    growing interest

    in the optimised

    use of the energy

    carrier compressed

    air. This is a sub-

    stantial saving

    potential for

    operating costs.

    efectormetris

    helps to explore

    this potential.

    Measurement ofcompressed air consumption

    Optimised consumptionof compressed air

    Allocationof consumed quantities

    The integral

    4-digit LED display

    plus the statusLEDs allow infor-

    mation to be avail-

    able at the point

    of monitoring.

    Whether peak

    consumption,

    present or accu-

    mulated consump-

    tion: Set switch or

    alarm levels can be

    accessed and

    programmed via

    pushbutton.All settings can be

    protected using

    the electronic lock

    function.

    8 Nm3/h

    12Nm3/h

    5.5Nm3/h

    * See

    www.druckluft-effizient.de

  • 7/30/2019 Metris Compressed Air Brochure UK

    3/6

    480

    6,096

    16,176

    63,360

    144

    1,488

    3,984

    15,840

    1.0

    12.7

    33.7

    132.0

    0.3

    3.1

    8.3

    33.0

    1.8

    20.8

    58.5

    235.2

    1.2

    11.1

    30.9

    123.8

    1

    3

    5

    10

    Hole

    [mm]

    Airloss

    at6 bar[l/s]

    Airloss

    at12 bar

    [l/s]

    Energyloss

    kWhat

    6 bar

    Energyloss

    kWhat

    12 bar

    Costat

    6 bar

    [EUR]

    Costat

    12 bar

    [EUR]

    The installation

    of several measur-

    ing points in the

    compressed air

    system clearly

    shows where and

    how much com-

    pressed air is con-

    sumed. Thus the

    consumption can

    be allocated to

    production

    processes or prod-

    ucts for optimising

    cost structure.

    Decentralised

    location ofefector

    metris in the sup-

    ply pipe to the

    individual

    machine unit.

    Location of

    efectormetris in

    the supply pipe

    prior to distribu-

    tion to several

    installations or

    machine units.

    eakage monitoring

    Two reliable indications of air leakageare the increase in consumption of com-pressed air with unchanged machine

    load and the continuing consumptionof compressed air when the machine isno longer in operation.

    Leakage at a glance.

    The compressed air meters integratedpipe length ensures easy mountingand high measurement accuracy.

    Easy to mountin the supply system.

    R

    Annual energy costs due to leakage:

    kWh x 0.06 EUR x 8000 operating hours/a.;

    Source: www.druckluft-effizient.de

  • 7/30/2019 Metris Compressed Air Brochure UK

    4/6

    MODE/ENTER SET

    From now on: Accurate monitor-

    ing of compressed air consump-

    tion with efector metris.

    The low purchase price makes it

    possible: To measure compressed

    air where it is used.

    Even very small leaks are detect-

    ed and can be repaired in good

    time.

    The quantities consumed can be

    directly allocated to the relevant

    production units.

    In situ display of total or current

    consumption.

    Switching, pulse or analogue

    outputs for further external

    processing.Determine maintenance intervals

    depending on consumption.

    Measurement free from pressure

    loss due to a special design of

    the measuring probes.

    Response time in the millisecond

    range.

    Calorimetricmeasuring principle

    Integrated

    display fordirectindication ofconsumption.

    Even small leaks

    can cause unneces-sary electricity

    costs of several

    thousand Euro

    per year.

    The calorimetric

    principle measures

    the standard

    volume flow

    irrespective of

    temperature and

    pressure quickly

    and over a wide

    measuring range.

    Leakage detection, energy costreduction and environmental protection.

  • 7/30/2019 Metris Compressed Air Brochure UK

    5/6

    *SP = switch point, **ASP = analogue start point, ***AEP = analogue end point

    Application

    Electrical design

    Connection

    Compressed air in industrial use

    DC PNP

    4-wire

    Technical data efector metris

    Output 1

    Output 2 (programmable)

    Operating voltage [V]

    Current rating [mA]

    Short-circuit protection, pulsed

    Reverse polarity/overload prot.

    Analogue output

    Pressure resistance [bar]

    Medium temperature [C]

    Power on delay time

    Response time [s]

    Measuring error in themeasuring range

    Repeatability

    Function displaySwitching statusDisplay

    Connection

    19...30 DC

    2 x 250

    4...20 mA (max. 500 )

    16

    0...60 (max. 90 % relative air humidity)

    0.5 s

    < 0.1

    (3 % measured value + 0.3 % final value of the measuring range)

    1 % of the measured value

    2 x yellow4-digit alphanumeric display

    Operating temperature [C] 0...60

    Protection IP 65 III

    Material housing PBT-GF20; PC; Makrolon; stainless steel (304S15); Viton

    Material sensor stainless steel (304S15); ceramics; PEEK; polyester

    M 12 connector

    2 x NC /NO programmable or 1 x NC /NO programmableand 1 x analogue 4...20 mA

    or 1 x NC/ NO programmable and 1 x pulse output (1 pulse = 1 l or 1 m3)

    Measuring range[Nl/min / Nm3 / h]

    Setting rangeSP* [Nl/min / Nm3 / h]ASP** [Nl/min / Nm3 / h]AEP*** [Nl/min / Nm3 / h]

    Pipe connection

    Order no.

    Sockets

    DescriptionOrder

    no.

    2 m PUR, M 12 straight, without LED E10906

    5 m PUR, M 12 straight, without LED E10907

    76,

    8

    45

    LEDdisplay

    programmingbuttons

    R

    90

    300

    16,1

    21,3

    M12x1

    100

    111,5

    Example: SD6000

    4...1,250 /0.25...75

    12.5...3,750 /0.75...225

    6...1,250 / 0.4...750...938 / 0...56.3

    313...1,250 / 18.8...75

    19...3,750 / 1.1...2250...2,812 / 0...169

    937...3,750 / 56...225

    DN15 DN25

    SD6000 SD8000

    0.039...11.67 x 103/2.3...700

    0.0...11.67 x 103/ 4...7000.0...8.75 x 103/ 0...525

    2.92...11.67x103/175...700

    DN50

    SD2000

    22.2...8,000 /1.3...400

    30...6,670 / 2...4000...5,130 / 0...307.5

    1,710...6,670 / 102...400

    DN40

    SD9000

  • 7/30/2019 Metris Compressed Air Brochure UK

    6/6

    Over 70 locations worldwide at a glance at www.ifm-electronic.com

    ifmarticleno.

    7511082

    Wereservetherighttomaketechnicalalterationswitho

    utpriornotice.PrintedinGermanyonnon-chlorineblea

    chedpaper.01/05

    ifm electronic gmbh

    Teichstrae 4D-45127 EssenTel. 02 01 / 2 42 20

    Fax 02 01 / 2 42 22 00e-mail:

    [email protected]

    http://w

    ww.ifm-electro

    nic.com

    visitou

    rwebsit

    e

    Position sensors

    Proximity switches

    Actuator sensors

    Photoelectric sensors

    Photoelectric systems

    Incremental andabsolute encoders

    Evaluation systems

    Power supplies

    Fluid sensors

    and diagnostic systems

    Inductive sensors for valves

    Level sensors

    Flow sensors

    Pressure sensors

    Vacuum sensors

    Temperature sensors

    Diagnostic systems

    Networkingand control