HWS CYLINDER HWS CYLINDER 16,000 LITRE COLD WATER STORAGE TANK * * * TPSV 100mm GAS HEADER 100mm MS GAS 80 FO DHWS SECONDARY CIRCULATION PUMP SET 54mm SBMCWS 35mm SBTCWS RISE TO HIGH LEVEL 54mm SBMCWS TO CYLINDERS 54mm SBMCWS FROM ONN'N 28mm SBMCWS TO HIGH LEVEL TANK 100mm PRIMARY HTG RETURN TO BOILERS EADER c/w IV & STRAINER SEE CONN'N DETAILS WATER SOFTENER Mitton INSITE SPRING 2012 T 01274 691177 E [email protected] W www.mittonmechanical.com Sustainability is a vital consideration for Mitton in everything we do. Environmental issues play a major role in scheme design and construction, and our key objective is to provide our customers with effective and efficient solutions, with respect to emerging concepts such as Simplified Building Energy Modelling and whole building life calculations from concept to eventual demolition. AFTERCARE P4 PORTABLE PLANT ROOMS CONTRACTING P2 SHEFFIELD HALLAM UNIVERSITY P2 STORES OF THE FUTURE AIR CONDITIONING P4 COOL RUNNINGS! P4 DON’T FORGET ENVIRONMENTAL P1 MORRISONS’ INNOVATIVE BRIDGWATER RDC RATED ‘BREEAM EXCELLENT’ MORRISONS’ INNOVATIVE BRIDGWATER RDC RATED ‘BREEAM EXCELLENT’ When modelling for Morrisons’ new Regional Distribution Centre in Bridgwater, the entire team from design and construction through to mechanical and electrical services worked closely together with the remit to achieve a post construction BREEAM Excellent rating on completion of the build. Innovation was the driver for Morrisons’ Bridgwater RDC team, reflecting the supermarket giant’s own commitment to environmentally sustainable practices. From the incorporation of solar panels to heat the hot water on the bulk warehouse office and transport office through to rainwater harvesting systems for flushing toilets and the inclusion of shut off valves, non-concussive taps and drives which ramp down when not needed, the entire site is a model for sustainability. Air rotation systems in the warehouses provide effective frost protection heating. All systems link into a comprehensive Building Monitoring System to achieve and maintain optimum levels of performance across the board. SBEM (Simplified Building Energy Model) calculations were completed by Mitton to determine CO 2 emission rates, with Mitton carrying out a site-wide EPC for BREEAM purposes as well as individual building EPCs. The post-construction BREEAM Excellent rating achieved reflects the commitment, drive and dedication of the entire team.

Mitton Insite Newsletter Spring 12

Embed Size (px)

DESCRIPTION

News from Mitton Mechanical.

Citation preview

Page 1: Mitton Insite Newsletter Spring 12

DNDO

DP

DR

DS

DNDO

DP

DR

up

fire escape/service access

DNDO

DP

DR

ssl +13.850

ffl +14.180

up

HTG EXPANSION

VESSEL

HTG EXPANSION

VESSEL

HWS EXPANSION

VESSEL

GAS FIRED

WATER HEATER

GAS FIRED

WATER HEATER

HWS CYLINDER

HWS CYLINDER

16,000 LITRE COLD WATER

STORAGE TANK

**

*

MAKE UP

UNIT

TPSV

SV

TPSV

SV

SV

SV

AHU1

DOC

DOC

BOOSTER SETDOC

AAC

SV

DOSING

POT

M

RISE TO

HIGH LEVEL

100mm GAS HEADER

100mm MS GAS

RISE TO

HIGH LEVEL

80mm HTG F&R TO SERVE AHU1

FOR CONN'S SEE SCHEMATIC DWG

DHWS SECONDARY

CIRCULATION PUMP SET

54mm HWS FLOW c/w IV

40mm MS GAS DROP TO LOW LEVEL WITH

20mm VALVED CONN'N TO WATER HEATER

100mm MS GAS TO BOILER PLANT

c/w SOLENOID VALVE

50mm GAS

100mm PRIMARY HTG FLOW FROM

BOILERS TO LOW LOSS HEADER c/w IV

100mm HTG FLOW TO STORE c/w IV

54mm SBMCWS

35mm SBTCWS RISE

TO HIGH LEVEL

54mm SBMCWS TO CYLINDERS

54mm COLD FEED TO CYLINDER

100mm HTG RETURN FROM STORE

TO LOW LOSS HEADER c/w IV

50mm MAKE UP LINE TO SYSTEM c/w IV

54mm BMCWS RISE TO HIGH LEVEL

22mm MCWS DTLL WITH 15mm VALVED

CONN'N TO MAKE UP UNIT c/w IV &

15mm TO BIBTAP c/w IV & DCV

40mm BRANCH TO EXPANSION VESSELS

WITH 20mm CONN'N TO EACH UNIT

54mm BMCWS TO 28mm INLET

CONN'N ON WATER SOFTENER

54mm MCWS TO 40mm DECCA BALL

VALVE c/w COMBINED IV/STRAINER

IN RAISED BALL VALVE HOUSING

22mm MCWS

100mm HTG F&R

35mm SBTCWS

54x28mm HWS F&R

54mm BMCWS

80mm GAS

54mm SBMCWS FROM

28mm OUTLET CONN'N

ON WATER SOFTENER

54mm MCWS

22x15mm HWS F&R

22mm BMCWS

150mm GAS

35mm SBTCWS DROP TO

BOOSTER SET c/w IV

28mm SBMCWS TO

HIGH LEVEL TANK

54mm HWS FLOW c/w IV

28mm HWS RETURN TO 20mm DRAIN

CONN'N ON HEATER c/w IV & FIT

15mm DOC ON BRANCH

50mm EXPANSION LINE TO

LOW LOSS HEADER c/w LSV

100mm PRIMARY HTG RETURN TO BOILERS

FROM LOW LOSS HEADER c/w IV & STRAINER

MIKROFILL MAKE UP/PRESSURISATION UNIT

54mm COLD FEED TO BOOSTER SET

FRESH AIR DUCT DROP

TO LOW LEVEL

PLANT ROOM VENTILATION AIR DUCT

CONNECT TO HIGH LEVEL COWL &

DROP TO LOW LEVEL GRILLE

RETURN AIR DUCT FROM

MAIN SALES

SUPPLY AIR DUCT TO

BAKERY

SUPPLY AIR DUCT TO

TEACAKE COOLER

SUPPLY AIR DUCT TO

MAIN SALES

LINE OF EXISTING DRAIN

PLANT ROOM VENTILATION AIR DUCT

AT HIGH LEVEL EXTRACT AIR DUCT FROM DELI

EXTRACT AIR DUCT FROM BAKERY

SEE CONN'N DETAILS

BOILER CONNECTION DETAILS

50mm HTG F&R WITH 40mm VALVED CONN'S TO UNIT

65mm MS GAS WITH 32mm VALVED CONN'N TO UNIT

WATER SOFTENER

NOTES

Architect

written permission from MITTON MECHANICAL SERVICES.

This drawing is copyright and should not be reproduced without

This Drawing Was Produced Using

Architects

Sub Cont'r

No dimensions to be scaled from this drawing unless otherwise stated.

Wm MORRISON SUPERMARKETS PLC

Gain LaneHilmore House

Bradford BD3 7DL

Property & Development Division

New Brighton_206_Rev B_FIRST FLOOR GA PLAN

*****

Revision

Drawn

Drawing Number

Date

Scale

Title

Job Number

Engineer

Project

Checked

BD12 0HSLow Moor, Bradford451 Cleckheaton RoadMacKenzie House

MittonMitton Mechanical Services

T: 01274 691177

F: 01274 691188

E:W: www.mittonmechanical.com

Wm MORRISON SUPERMARKETS PLC

NEW BRIGHTON

PLANT ROOM LAYOUT

1:20 @ A04236

DECEMBER 2010DI RC DI

4236/M/10B

CONSTRUCTION

[email protected]

South Park Way | Wakefield 41 Business Park

WAKEFIELD | WF2 0XJ

Tel : 01924 858585 | Fax : 01924 858555

Email : [email protected]

www.dla-architecture.co.uk

DLA ARCHITECTURE

CHKDDRWN

REV DATEDESCRIPTION

NOTES ADDED.

A 14/02/10

RC DIREVISED TO SUIT NEW LAYOUT.

MADE CONSTRUCTION ISSUE.B 11/05/11

RC DI

Mitton INSITESPRING 2012

T 01274 691177 E [email protected] W www.mittonmechanical.com

Sustainability is a vital consideration for Mitton in everything we do. Environmental issues play a major role in scheme design and construction, and our key objective is to provide our customers with effective and efficient solutions, with respect to emerging concepts such as Simplified Building Energy Modelling and whole building life calculations from concept to eventual demolition.

AFTERCAREP4 PORTABLE PLANT ROOMS

HELPLINE

CONTRACTINGP2 SHEFFIELD HALLAM UNIVERSITY

P2 STORES OF THE FUTURE

AIR CONDITIONINGP4 COOL RUNNINGS!

P4 DON’T FORGET

ENVIRONMENTALP1 MORRISONS’ INNOVATIVE BRIDGWATER RDC RATED ‘BREEAM EXCELLENT’

MORRISONS’ INNOVATIVE BRIDGWATER RDC RATED ‘BREEAM EXCELLENT’

When modelling for Morrisons’ new Regional Distribution Centre in Bridgwater, the entire team from design and construction through to mechanical and electrical services worked closely together with the remit to achieve a post construction BREEAM Excellent rating on completion of the build.

Innovation was the driver for Morrisons’ Bridgwater RDC team, reflecting the supermarket giant’s own commitment to environmentally sustainable practices. From the incorporation of solar panels to heat the hot water on the bulk warehouse office and transport office through to rainwater harvesting systems for flushing toilets and the inclusion of shut off valves, non-concussive taps and drives which ramp down when not

needed, the entire site is a model for sustainability. Air rotation systems in the warehouses provide effective frost protection heating.

All systems link into a comprehensive Building Monitoring System to achieve and maintain optimum levels of performance across the board.

SBEM (Simplified Building Energy Model) calculations were completed by Mitton to determine CO

2 emission rates, with Mitton carrying out a

site-wide EPC for BREEAM purposes as well as individual building EPCs.

The post-construction BREEAM Excellent rating achieved reflects the commitment, drive and dedication of the entire team.

Page 2: Mitton Insite Newsletter Spring 12

DNDO

DP

DR

DS

DNDO

DP

DR

up

fire escape/service access

DNDO

DP

DR

ssl +13.850

ffl +14.180

up

HTG EXPANSION

VESSEL

HTG EXPANSION

VESSEL

HWS EXPANSION

VESSEL

GAS FIRED

WATER HEATER

GAS FIRED

WATER HEATER

HWS CYLINDER

HWS CYLINDER

16,000 LITRE COLD WATER

STORAGE TANK

**

*

MAKE UP

UNIT

TPSV

SV

TPSV

SV

SV

SV

AHU1

DOC

DOC

BOOSTER SETDOC

AAC

SV

DOSING

POT

M

RISE TO

HIGH LEVEL

100mm GAS HEADER

100mm MS GAS

RISE TO

HIGH LEVEL

80mm HTG F&R TO SERVE AHU1

FOR CONN'S SEE SCHEMATIC DWG

DHWS SECONDARY

CIRCULATION PUMP SET

54mm HWS FLOW c/w IV

40mm MS GAS DROP TO LOW LEVEL WITH

20mm VALVED CONN'N TO WATER HEATER

100mm MS GAS TO BOILER PLANT

c/w SOLENOID VALVE

50mm GAS

100mm PRIMARY HTG FLOW FROM

BOILERS TO LOW LOSS HEADER c/w IV

100mm HTG FLOW TO STORE c/w IV

54mm SBMCWS

35mm SBTCWS RISE

TO HIGH LEVEL

54mm SBMCWS TO CYLINDERS

54mm COLD FEED TO CYLINDER

100mm HTG RETURN FROM STORE

TO LOW LOSS HEADER c/w IV

50mm MAKE UP LINE TO SYSTEM c/w IV

54mm BMCWS RISE TO HIGH LEVEL

22mm MCWS DTLL WITH 15mm VALVED

CONN'N TO MAKE UP UNIT c/w IV &

15mm TO BIBTAP c/w IV & DCV

40mm BRANCH TO EXPANSION VESSELS

WITH 20mm CONN'N TO EACH UNIT

54mm BMCWS TO 28mm INLET

CONN'N ON WATER SOFTENER

54mm MCWS TO 40mm DECCA BALL

VALVE c/w COMBINED IV/STRAINER

IN RAISED BALL VALVE HOUSING

22mm MCWS

100mm HTG F&R

35mm SBTCWS

54x28mm HWS F&R

54mm BMCWS

80mm GAS

54mm SBMCWS FROM

28mm OUTLET CONN'N

ON WATER SOFTENER

54mm MCWS

22x15mm HWS F&R

22mm BMCWS

150mm GAS

35mm SBTCWS DROP TO

BOOSTER SET c/w IV

28mm SBMCWS TO

HIGH LEVEL TANK

54mm HWS FLOW c/w IV

28mm HWS RETURN TO 20mm DRAIN

CONN'N ON HEATER c/w IV & FIT

15mm DOC ON BRANCH

50mm EXPANSION LINE TO

LOW LOSS HEADER c/w LSV

100mm PRIMARY HTG RETURN TO BOILERS

FROM LOW LOSS HEADER c/w IV & STRAINER

MIKROFILL MAKE UP/PRESSURISATION UNIT

54mm COLD FEED TO BOOSTER SET

FRESH AIR DUCT DROP

TO LOW LEVEL

PLANT ROOM VENTILATION AIR DUCT

CONNECT TO HIGH LEVEL COWL &

DROP TO LOW LEVEL GRILLE

RETURN AIR DUCT FROM

MAIN SALES

SUPPLY AIR DUCT TO

BAKERY

SUPPLY AIR DUCT TO

TEACAKE COOLER

SUPPLY AIR DUCT TO

MAIN SALES

LINE OF EXISTING DRAIN

PLANT ROOM VENTILATION AIR DUCT

AT HIGH LEVEL EXTRACT AIR DUCT FROM DELI

EXTRACT AIR DUCT FROM BAKERY

SEE CONN'N DETAILS

BOILER CONNECTION DETAILS

50mm HTG F&R WITH 40mm VALVED CONN'S TO UNIT

65mm MS GAS WITH 32mm VALVED CONN'N TO UNIT

WATER SOFTENER

NOTES

Architect

written permission from MITTON MECHANICAL SERVICES.

This drawing is copyright and should not be reproduced without

This Drawing Was Produced Using

Architects

Sub Cont'r

No dimensions to be scaled from this drawing unless otherwise stated.

Wm MORRISON SUPERMARKETS PLC

Gain LaneHilmore House

Bradford BD3 7DL

Property & Development Division

New Brighton_206_Rev B_FIRST FLOOR GA PLAN

*****

Revision

Drawn

Drawing Number

Date

Scale

Title

Job Number

Engineer

Project

Checked

BD12 0HSLow Moor, Bradford451 Cleckheaton RoadMacKenzie House

MittonMitton Mechanical Services

T: 01274 691177

F: 01274 691188

E:W: www.mittonmechanical.com

Wm MORRISON SUPERMARKETS PLC

NEW BRIGHTON

PLANT ROOM LAYOUT

1:20 @ A04236

DECEMBER 2010DI RC DI

4236/M/10B

CONSTRUCTION

[email protected]

South Park Way | Wakefield 41 Business Park

WAKEFIELD | WF2 0XJ

Tel : 01924 858585 | Fax : 01924 858555

Email : [email protected]

www.dla-architecture.co.uk

DLA ARCHITECTURE

CHKDDRWN

REV DATEDESCRIPTION

NOTES ADDED.

A 14/02/10

RC DIREVISED TO SUIT NEW LAYOUT.

MADE CONSTRUCTION ISSUE.B 11/05/11

RC DI

2

One of the UK’s most progressive and innovative universities, Sheffield Hallam University has a vision to be renowned as a forward thinking, enterprising and business engaged university, known for providing a high quality and cutting edge learning experience.

The Owen Building is the main building at City Campus, providing learning facilities for the Faculty of Development and Society, the Sheffield Business School and the Faculty of Health and Wellbeing, with facilities including laboratories, kitchens and studios.

Working closely with main contractors Illingworth & Gregory, Mitton has now completed work on a complete upgrade of the building’s low pressure hot water heating installation,

moving this back to the distribution mains and providing new radiators and distribution pipework.

The contract also called for removal of an existing redundant ventilation system and installation of a new, naturally ventilated system using four solar operated windcatchers located on the roof to provide the fresh air requirements of the space. Designed for optimum energy efficiency, the windcatchers incorporate solar panels which operate internal fans and dampers.

Mitton has also installed a new control system, linking the natural ventilation facility and radiators to interface with the existing Building Management System.

Work has started on the first tranche of Morrisons’ new ‘Store of the Future’, with all mechanical services works provided by Mitton, assisting the main contractor with the refurbishment of food preparation areas and well as alterations and extensions to existing hot and cold water and ventilation systems.

The Store of the Future focus on an innovative and wide-ranging, premium fresh food offer, yet still delivering Morrisons’ great value. Embracing more flexible store formats, they aim to retain

Morrisons’ key differentiators of value, affordability and freshness, coupling this with a premium range of gourmet foods and high quality culinary produce.

Morrisons already has more people preparing more food in store than any other retailer, with fully trained fishmongers, butchers and bakers on hand offering expert knowledge of their product areas.

WORK STARTS ON MORRISONS’ ‘STORE OF THE FUTURE’

SHEFFIELD HALLAM UNIVERSITYNEW HEATING AND WINDCATCHER VENTILATION SYSTEMS

Page 3: Mitton Insite Newsletter Spring 12

DNDO

DP

DR

DS

DNDO

DP

DR

up

fire escape/service access

DNDO

DP

DR

ssl +13.850

ffl +14.180

up

HTG EXPANSION

VESSEL

HTG EXPANSION

VESSEL

HWS EXPANSION

VESSEL

GAS FIRED

WATER HEATER

GAS FIRED

WATER HEATER

HWS CYLINDER

HWS CYLINDER

16,000 LITRE COLD WATER

STORAGE TANK

**

*

MAKE UP

UNIT

TPSV

SV

TPSV

SV

SV

SV

AHU1

DOC

DOC

BOOSTER SETDOC

AAC

SV

DOSING

POT

M

RISE TO

HIGH LEVEL

100mm GAS HEADER

100mm MS GAS

RISE TO

HIGH LEVEL

80mm HTG F&R TO SERVE AHU1

FOR CONN'S SEE SCHEMATIC DWG

DHWS SECONDARY

CIRCULATION PUMP SET

54mm HWS FLOW c/w IV

40mm MS GAS DROP TO LOW LEVEL WITH

20mm VALVED CONN'N TO WATER HEATER

100mm MS GAS TO BOILER PLANT

c/w SOLENOID VALVE

50mm GAS

100mm PRIMARY HTG FLOW FROM

BOILERS TO LOW LOSS HEADER c/w IV

100mm HTG FLOW TO STORE c/w IV

54mm SBMCWS

35mm SBTCWS RISE

TO HIGH LEVEL

54mm SBMCWS TO CYLINDERS

54mm COLD FEED TO CYLINDER

100mm HTG RETURN FROM STORE

TO LOW LOSS HEADER c/w IV

50mm MAKE UP LINE TO SYSTEM c/w IV

54mm BMCWS RISE TO HIGH LEVEL

22mm MCWS DTLL WITH 15mm VALVED

CONN'N TO MAKE UP UNIT c/w IV &

15mm TO BIBTAP c/w IV & DCV

40mm BRANCH TO EXPANSION VESSELS

WITH 20mm CONN'N TO EACH UNIT

54mm BMCWS TO 28mm INLET

CONN'N ON WATER SOFTENER

54mm MCWS TO 40mm DECCA BALL

VALVE c/w COMBINED IV/STRAINER

IN RAISED BALL VALVE HOUSING

22mm MCWS

100mm HTG F&R

35mm SBTCWS

54x28mm HWS F&R

54mm BMCWS

80mm GAS

54mm SBMCWS FROM

28mm OUTLET CONN'N

ON WATER SOFTENER

54mm MCWS

22x15mm HWS F&R

22mm BMCWS

150mm GAS

35mm SBTCWS DROP TO

BOOSTER SET c/w IV

28mm SBMCWS TO

HIGH LEVEL TANK

54mm HWS FLOW c/w IV

28mm HWS RETURN TO 20mm DRAIN

CONN'N ON HEATER c/w IV & FIT

15mm DOC ON BRANCH

50mm EXPANSION LINE TO

LOW LOSS HEADER c/w LSV

100mm PRIMARY HTG RETURN TO BOILERS

FROM LOW LOSS HEADER c/w IV & STRAINER

MIKROFILL MAKE UP/PRESSURISATION UNIT

54mm COLD FEED TO BOOSTER SET

FRESH AIR DUCT DROP

TO LOW LEVEL

PLANT ROOM VENTILATION AIR DUCT

CONNECT TO HIGH LEVEL COWL &

DROP TO LOW LEVEL GRILLE

RETURN AIR DUCT FROM

MAIN SALES

SUPPLY AIR DUCT TO

BAKERY

SUPPLY AIR DUCT TO

TEACAKE COOLER

SUPPLY AIR DUCT TO

MAIN SALES

LINE OF EXISTING DRAIN

PLANT ROOM VENTILATION AIR DUCT

AT HIGH LEVEL EXTRACT AIR DUCT FROM DELI

EXTRACT AIR DUCT FROM BAKERY

SEE CONN'N DETAILS

BOILER CONNECTION DETAILS

50mm HTG F&R WITH 40mm VALVED CONN'S TO UNIT

65mm MS GAS WITH 32mm VALVED CONN'N TO UNIT

WATER SOFTENER

NOTES

Architect

written permission from MITTON MECHANICAL SERVICES.

This drawing is copyright and should not be reproduced without

This Drawing Was Produced Using

Architects

Sub Cont'r

No dimensions to be scaled from this drawing unless otherwise stated.

Wm MORRISON SUPERMARKETS PLC

Gain LaneHilmore House

Bradford BD3 7DL

Property & Development Division

New Brighton_206_Rev B_FIRST FLOOR GA PLAN

*****

Revision

Drawn

Drawing Number

Date

Scale

Title

Job Number

Engineer

Project

Checked

BD12 0HSLow Moor, Bradford451 Cleckheaton RoadMacKenzie House

MittonMitton Mechanical Services

T: 01274 691177

F: 01274 691188

E:W: www.mittonmechanical.com

Wm MORRISON SUPERMARKETS PLC

NEW BRIGHTON

PLANT ROOM LAYOUT

1:20 @ A04236

DECEMBER 2010DI RC DI

4236/M/10B

CONSTRUCTION

[email protected]

South Park Way | Wakefield 41 Business Park

WAKEFIELD | WF2 0XJ

Tel : 01924 858585 | Fax : 01924 858555

Email : [email protected]

www.dla-architecture.co.uk

DLA ARCHITECTURE

CHKDDRWN

REV DATEDESCRIPTION

NOTES ADDED.

A 14/02/10

RC DIREVISED TO SUIT NEW LAYOUT.

MADE CONSTRUCTION ISSUE.B 11/05/11

RC DI

3

Major investment in IT facilities is now under way at Mitton, upgrading the company’s technological platforms and aiming to secure the future by putting the infrastructure in place to facilitate planned growth to 2017.

The investment is designed around providing enhanced services for customers, with significantly increased capacity and speeds when connecting in to Mitton’s network.

To achieve this, Mitton is renewing the servers that provide IT solutions for whole of the Mitton Group, including Aftercare, Environmental, Contracting and Air Conditioning. The work is being carried out by Andisa, specialist providers of computer networks and systems, who have worked with Mitton for over a decade.

“This project represents a significant investment for Mitton, replacing our existing servers with new, ‘greener’ Dell models complete with Intel processors,” confirmed Graham Hawe. “The advanced units offer reduced power consumption together with improved performance, enabling us to manage data more efficiently for our clients. This increased productivity and capacity will enable us to implement our planned business strategies across the different divisions within the Group.”

The decision to bring our emergency helpline in-house is already paying dividends for our clients – and in a couple of notable cases, for other people’s clients too!

One recent call resulted in our engineers solving a problem for one of our retail clients, even though the installation in question was not one of ours! As a result, the systems were up and running again almost immediately without any material loss.

As our business and our clients grow, we now have more and more buildings, plant and equipment under our care. Through our nationwide helpdesk service, manned 24/7 by trained engineers with an in-depth knowledge of our systems and services, we are seeing substantial reductions in our average response times.

In addition, this in-house call centre is realising savings for our clients in terms of time and cost by dealing with problems swiftly and professionally, backed up by our nationwide network of engineers to attend on site and availability of spares.

Leeds Trinity University College is a Catholic University College with a student body numbering just under 3,000. Working closely with consulting engineers David Daccus & Associates, Mitton was contracted to provide a new control valve for the chapel heating circuit, together with the installation of inverter drives to the existing teaching block heating pumps in the main boiler room.

The company also provided a new Building Management System connection from the Trend outstation in the boiler room to provide status control, on/off fault and speed control, as well as new computer graphics for the Estates Office Trend 963 terminal.

LEEDS TRINITY UNIVERSITY COLLEGE INVESTING IN THE TECHNOLOGICAL INFRASTRUCTURE

DRIVING EFFICIENCYMITTON’S IN-HOUSE CALL CENTRE AT WORK!

Using our broad ranging expertise across the mechanical services sector, Mitton is increasingly being commissioned to act as Principal Contractor for projects of significant scale.

Alliance Healthcare is one of the UK’s leading distributors and wholesalers of pharmaceutical, medical and healthcare products, offering innovative added-value services to healthcare manufacturers and to dispensing points across the UK.

When the organisation was looking to revise the layout of offices, meeting rooms and store room accommodation at its Head Office in Chessington, Surrey, Mitton was appointed as Principal Contractor to manage the project.

The work involved removal of existing partitioned offices, adding new and amending existing services to accommodate the altered layout, including all associated electrical works.

The Mitton team isolated the drains and removed all heating/cooling ceiling mounted fan coil units within existing cellular office

accommodation, including associated branch pipework. Following construction of the revised partitioned layout, Mitton provided heating/cooling to five new meeting rooms, utilising fan coil units with connections into the existing constant temperature heating pipework and existing chilled water pipework within the ceiling void. Each included a ducted fresh air facility and extract.

Two redundant DX cooling split systems within the roof void were removed, including external condensing units, with the team working outside office hours to minimise disruption.

The constant temperature and chilled water systems were refilled and revented, and essential alterations and extensions made to the automatic controls installations, together with the installation of thermal insulation, new ceilings, doors, carpeting and decorations.

The work was completed on time and to budget, with all electrical installations carried out by specialists from Bradford-based Pitts Wilson Electrical.

MITTON TAKES ON PRINCIPAL CONTRACTOR ROLE FOR ALLIANCE HEALTHCARE

Page 4: Mitton Insite Newsletter Spring 12

DNDO

DP

DR

DS

DNDO

DP

DR

up

fire escape/service access

DNDO

DP

DR

ssl +13.850

ffl +14.180

up

HTG EXPANSION

VESSEL

HTG EXPANSION

VESSEL

HWS EXPANSION

VESSEL

GAS FIRED

WATER HEATER

GAS FIRED

WATER HEATER

HWS CYLINDER

HWS CYLINDER

16,000 LITRE COLD WATER

STORAGE TANK

**

*

MAKE UP

UNIT

TPSV

SV

TPSV

SV

SV

SV

AHU1

DOC

DOC

BOOSTER SETDOC

AAC

SV

DOSING

POT

M

RISE TO

HIGH LEVEL

100mm GAS HEADER

100mm MS GAS

RISE TO

HIGH LEVEL

80mm HTG F&R TO SERVE AHU1

FOR CONN'S SEE SCHEMATIC DWG

DHWS SECONDARY

CIRCULATION PUMP SET

54mm HWS FLOW c/w IV

40mm MS GAS DROP TO LOW LEVEL WITH

20mm VALVED CONN'N TO WATER HEATER

100mm MS GAS TO BOILER PLANT

c/w SOLENOID VALVE

50mm GAS

100mm PRIMARY HTG FLOW FROM

BOILERS TO LOW LOSS HEADER c/w IV

100mm HTG FLOW TO STORE c/w IV

54mm SBMCWS

35mm SBTCWS RISE

TO HIGH LEVEL

54mm SBMCWS TO CYLINDERS

54mm COLD FEED TO CYLINDER

100mm HTG RETURN FROM STORE

TO LOW LOSS HEADER c/w IV

50mm MAKE UP LINE TO SYSTEM c/w IV

54mm BMCWS RISE TO HIGH LEVEL

22mm MCWS DTLL WITH 15mm VALVED

CONN'N TO MAKE UP UNIT c/w IV &

15mm TO BIBTAP c/w IV & DCV

40mm BRANCH TO EXPANSION VESSELS

WITH 20mm CONN'N TO EACH UNIT

54mm BMCWS TO 28mm INLET

CONN'N ON WATER SOFTENER

54mm MCWS TO 40mm DECCA BALL

VALVE c/w COMBINED IV/STRAINER

IN RAISED BALL VALVE HOUSING

22mm MCWS

100mm HTG F&R

35mm SBTCWS

54x28mm HWS F&R

54mm BMCWS

80mm GAS

54mm SBMCWS FROM

28mm OUTLET CONN'N

ON WATER SOFTENER

54mm MCWS

22x15mm HWS F&R

22mm BMCWS

150mm GAS

35mm SBTCWS DROP TO

BOOSTER SET c/w IV

28mm SBMCWS TO

HIGH LEVEL TANK

54mm HWS FLOW c/w IV

28mm HWS RETURN TO 20mm DRAIN

CONN'N ON HEATER c/w IV & FIT

15mm DOC ON BRANCH

50mm EXPANSION LINE TO

LOW LOSS HEADER c/w LSV

100mm PRIMARY HTG RETURN TO BOILERS

FROM LOW LOSS HEADER c/w IV & STRAINER

MIKROFILL MAKE UP/PRESSURISATION UNIT

54mm COLD FEED TO BOOSTER SET

FRESH AIR DUCT DROP

TO LOW LEVEL

PLANT ROOM VENTILATION AIR DUCT

CONNECT TO HIGH LEVEL COWL &

DROP TO LOW LEVEL GRILLE

RETURN AIR DUCT FROM

MAIN SALES

SUPPLY AIR DUCT TO

BAKERY

SUPPLY AIR DUCT TO

TEACAKE COOLER

SUPPLY AIR DUCT TO

MAIN SALES

LINE OF EXISTING DRAIN

PLANT ROOM VENTILATION AIR DUCT

AT HIGH LEVEL EXTRACT AIR DUCT FROM DELI

EXTRACT AIR DUCT FROM BAKERY

SEE CONN'N DETAILS

BOILER CONNECTION DETAILS

50mm HTG F&R WITH 40mm VALVED CONN'S TO UNIT

65mm MS GAS WITH 32mm VALVED CONN'N TO UNIT

WATER SOFTENER

NOTES

Architect

written permission from MITTON MECHANICAL SERVICES.

This drawing is copyright and should not be reproduced without

This Drawing Was Produced Using

Architects

Sub Cont'r

No dimensions to be scaled from this drawing unless otherwise stated.

Wm MORRISON SUPERMARKETS PLC

Gain LaneHilmore House

Bradford BD3 7DL

Property & Development Division

New Brighton_206_Rev B_FIRST FLOOR GA PLAN

*****

Revision

Drawn

Drawing Number

Date

Scale

Title

Job Number

Engineer

Project

Checked

BD12 0HSLow Moor, Bradford451 Cleckheaton RoadMacKenzie House

MittonMitton Mechanical Services

T: 01274 691177

F: 01274 691188

E:W: www.mittonmechanical.com

Wm MORRISON SUPERMARKETS PLC

NEW BRIGHTON

PLANT ROOM LAYOUT

1:20 @ A04236

DECEMBER 2010DI RC DI

4236/M/10B

CONSTRUCTION

[email protected]

South Park Way | Wakefield 41 Business Park

WAKEFIELD | WF2 0XJ

Tel : 01924 858585 | Fax : 01924 858555

Email : [email protected]

www.dla-architecture.co.uk

DLA ARCHITECTURE

CHKDDRWN

REV DATEDESCRIPTION

NOTES ADDED.

A 14/02/10

RC DIREVISED TO SUIT NEW LAYOUT.

MADE CONSTRUCTION ISSUE.B 11/05/11

RC DI

4

Winter boiler breakdowns, water stoppages and even boiler replacements need not mean disruptions to commercial processes, thanks to Mitton’s ingenious portable plant rooms, designed to deliver effective temporary solutions for contracts requiring reliable supplies of heat and hot water during repair or maintenance contracts.

Capable of taking over boiler room and associated functions to allow works to continue uninterrupted, Mitton’s ‘Heat Stores’ and ‘H2O Solutions’ mobile plant rooms are built inside containers and designed to be easily transportable from location to location, simply arriving on site and connecting into existing services.

The plant rooms are kept at Mitton Service Centres nationwide, facilitating a quick response anywhere on the UK mainland. Outside standard planned maintenance projects, Mitton’s Aftercare division aims to have the these flexible alternative supply systems up and running within 24 hours in emergency situations, providing heating and hot water services.

All equipment has been specified and purpose-built to ‘plug and play’ for optimum reliability. Dependent on capacity requirements, the units can be linked together to achieve the levels of supply performance required.

For more information, please contact Ian McWilliams - [email protected]

Our Air Conditioning division continues to see sustained rates of growth in all areas, from system installation through to servicing, repair and coolant replacement in line with changing legislation.

We’re seeing significant growth in the retail sector, particularly with smaller stores where there is a requirement for air conditioning across the space. These smaller stores often have no plant room, so air conditioning is a quick install which provides a universal heating and cooling solution across all weathers, especially where no gas supply is available.

With business growing in all areas, from split systems and variable refrigerant volume systems to multisystems, even at this time of year our teams are kept busy, providing year round comfort in all environments, from industrial though to retail.

Under EC regulations, CFCs have now been banned and HCFCs are being phased out. As of January 2010, virgin HCFCs cannot be used for servicing systems. Recycled HCFCs may be used only until January 2015.

In addition, the European Performance of Buildings Directive (EPBD) requires all air conditioning systems to have an Air Conditioning Energy Assessment (ACEA) at least once every five years. Systems with an output of at least 12kW power should have had their first ACEA before 4 January 2011 (4 January 2013 in Scotland). Systems with an output of more than 250kW should have been assessed by 4 January 2009. Contact Paul Bennett from our Air Conditioning Division if you have any queries.

PORTABLE PLANT ROOMS – HEAT AND WATER ON THE MOVEHEAT STORES & H2O SOLUTIONS

Mitton Mechanical Services LtdMackenzie House, 451 Cleckheaton Rd,Low Moor, Bradford BD12 0HS

Tel: 01274 [email protected]

Mitton operates nationwide with offices in Bradford, Northampton Swindon and Livingston.

COOL RUNNINGS!THE LOW DOWN ON AIR CON

DON’T FORGET: