Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
D
=
0
.
8
0
m
D
=
1
.
0
0
m
D
=
1
.
1
0
m
D
=
1
.
3
0
m
D
=
1
.
3
0
m
D
=
0
.
9
0
m
D
=
0
.
9
0
m
D
=
0
.
8
0
m
D
=
1
.
2
0
m
D
=
1
.
2
0
m
D
=
1
.
0
0
m
D
=
1
.
0
0
m
D
=
1
.
2
0
m
D
=
1
.
2
0
m
D
=
1
.
2
0
m
D
=
1
.
2
0
m
D
=
1
.
2
0
m
D
=
0
.
8
0
m
D
=
0
.
8
0
m
D
=
0
.
8
0
m
D
=
0
.
8
0
m
D
=
0
.
7
0
m
G
P
R
S
c
a
n
3
1
4
G
P
R
S
c
a
n
3
0
4
41.69
41.61
41.58
41.71
41.78
41.70
41.54
Mkr
C
o
n
c
r
e
t
e
H
t
=
0
.
1
0
m
4
1
.
6
4
4
1
.
7
2
4
1
.
8
1
4
1
.
8
3
4
1
.
8
1
4
1
.
7
5
4
1
.
7
3
4
1
.
7
7
41.60
E
l
e
c
t
r
i
c
F
e
n
c
e
H
t
=
2
.
6
0
m
C
o
n
c
r
e
t
e
H
t
=
0
.
1
0
m
D
=
1
.
0
0
m
E
l
e
c
t
r
i
c
F
e
n
c
e
H
t
=
2
.
6
0
m
4
1
.
4
8
4
1
.
6
1
4
1
.
6
1
4
1
.
6
6
4
1
.
5
9
4
1
.
5
8
4
1
.
6
0
4
1
.
6
8
4
1
.
6
5
P
a
l
i
s
a
d
e
F
e
n
c
e
B
/
W
H
t
=
2
.
3
0
m
ABBREVIATIONS
NOTES
REV. DETAILS BY
GRID DATUM
SURVEYED BY: DRAWN BY:
SCALE:
APPROVED BY:
SURVEY DATE:
REV:
DATE
CLIENT:
PROJECT TITLE:
DRAWING TITLE:
DRAWING NUMBER:
SHEET NUMBER:
Structure Overhead
Structure Underground
Building Canopy
Building Overhead
Wall
Structure
Building
Above Ground Pipe
Drainage Channel
Banking
Fence
Surface Edge
Road Kerb Channel
Road Edge
Vegetation Extents
Overhead Pipe
Overhead Electricity
Overhead Telecom
TOPOGRAPHICAL AND UTILITY LEGEND
Scar
Railway Track
Contour Line
220
LEEDS
E-Mail: [email protected] Web site: www.40seven.com
LONDON
01732 7406960113 201 9700
AC Asbestos Cement
ACU Air Conditioning Unit
AD Assumed Direction
AR Assumed Route
AV Air Valve
BB Belisha Beacon
BD Back Drop
BdL Bed Level
BH Borehole
Bk Brick
BL Basement Light
BO Bollard
BOC Bottom of Chamber
BR Brick
BS Bus Stop
BT British Telecom Cover
BTB British Telecom Box
BW Brick Wall
B/W Barbed Wire Fence
Cam Camera
CAT Catenary Level
C/B Close Boarded Fence
CC Control Cabinet
CCTV Close Circuit TV
CH Chainage
ChL Channel Level
CI Cast Iron
C/I Corrugated Iron Fence
CL Cover Level
C/L Chain Link Fence
CO Concrete
CP Catch Pit
CpL Coping Level
CTV Cable TV
CUL Culvert
CW Concrete Wall
DI Ductile Iron
dil Dilapidated
dis Disused
D/S Downstream
DSW Dry Stone Wall
EB Electricity Box
EC Electricity Cover
ED Empty Duct
E/F Electric Fence
EFP Electricity Feeder Pillar
EOT End of Trace
EP Electricity Pole
ER Earth Rod
FC Fuel Cover
FFL Finished Floor Level
FH Fire Hydrant
FO Fibre Optic Cover
FS Flag Staff
G Gully
GPRI Ground Penetrating
Radar Inconclusive
GrL Ground Light
GV Gas Valve
H/R Hand Rail
HV High Voltage
IC Inspection Cover
IL Invert Level
I/R Iron Rail Fence
KO Kerb Outlet
LB Letter Box
LC Lighting Column
LH Lamp Hole
LOR Loss Of Reflection
LOS Loss Of Signal
MB Mooring Bollard
M/C Multiple Cables
MH Manhole Cover
Mkr Marker Post
MP Mile Post/Stone
NFI No Further Information
NM Node Marker
NP Name Plate
NPV No Pipes Visible
OSA Off Survey Area
P Post
PBM Permanent Bench Mark
PE Polyethylene
PGM Permanent Ground
Marker
PL Plastic
P/L Palisade Fence
PM Parking Meter
P/R Post and Rail Fence
PS Poor Signal
PU Pump
PVC Polyvinylchloride
P/W Post and Wire Fence
PWR Power
PZ Piezometer
R Radio
RE Rodding Eye
Ri Riser
RL Roof Level
RP Reflector Post
RS Road Sign
RWP Rain Water Pipe
R/W Retaining Wall
S Stump
SA Survey Abandoned
S/A Soakaway
S/B Safety Barrier
SC Speed Camera
S/F Safety Fence
SI Spun Iron
SL Soffit Level
S/L Street Lighting (Electric)
SP Sign Post
Spr Spring
S/R Steel Railings
SS Sonde Stops
ST Stop Tap
STS Structural Support
Stn Survey Station
SV Sluice Valve
SVP Soil Vent Pipe
SW Stone Wall
Tac Tactile Paving
TBM Temporary Bench Mark
TC Telecom Cover
TCB Telephone Call Box
TCP Telephone Call Post
T/F Temporary Fence
TFR Taken From Records
TH Trial Hole / Pit
ThL Threshold Level
Tk Tank
TOW Top Of Wall
TP Telegraph Pole
TS Traffic Signals
TSC Traffic Signals Cover
U/S Upstream
UTGA Unable to Gain Access
UTL Unable to Locate
UTR Unable to Raise
UTS Unable to Survey
UTT Unable to Trace
VC Vitrified Clay
VDP Vehicle Detector Pad
VP Vent Pipe
VR Vapour Recovery
VTP Vertical Pipe
W Water Cover
WL Water Level
WM Water Meter
W/M Wire Mesh Fence
WO Wash Out
WS Window Sample
WV Wheel Valve
JN BENTLEY LTD
KEIGHLEY ROAD
SKIPTON
BD23 2QR
ROLLS ROYCE
TOPOGRAPHICAL AND GPR
SURVEY
LB / DS VK GJ
1:200 @ A2 07 / 2019
1803_P
1 of 17 A2
ORDNANCE SURVEY
RELATED TO THE OS
ACTIVE STATIONS BY
GPS OBSERVATIONS
ORDNANCE SURVEY
RELATED TO THE OS ACTIVE STATIONS BY
GPS OBSERVATIONS
Unknown
Unknown Route
Located By GPR
D
=
0
.
9
0
m
D
=
0
.
8
0
m
D
=
1
.
2
0
m
D
=
0
.
7
7
m
D
=
0
.
8
0
m
D
=
0
.
8
0
m
D
=
0
.
8
0
m
D
=
0
.
8
0
m
D
=
0
.
8
0
m
D
=
0
.
8
0
m
D
=
0
.
8
0
m
D
=
1
.
0
0
m
D
=
1
.
0
0
m
D
=
1
.
1
0
m
O
S
A
D
=
0
.
8
0
m
D
=
0
.
8
0
m
D
=
0
.
8
0
m
D
=
0
.
8
0
m
D
=
0
.
9
0
m
D
=
0
.
7
0
m
G
P
R
S
c
a
n
3
0
4
Gravel
41.33
41.62
41.68
41.48
41.54
41.70
41.69
41.61
41.58
Mkr
P
SP
41.25
41.1
1
4
1
.
1
9
4
1
.
3
2
41.2
3
4
1
.
2
1
4
1
.2
4
4
0
.
8
9
4
1
.
1
1
P
a
l
i
s
a
d
e
F
e
n
c
e
B
/
W
H
t
=
2
.
3
0
m
4
1
.
7
5
4
1
.
7
3
4
1
.
7
7
4
1
.
8
3
4
1
.
7
0
4
1
.
5
7
4
1
.
5
8
4
1
.
8
1
4
1
.
6
4
4
1
.
4
2
41.26
41.15
C
o
n
c
r
e
t
e
H
t
=
0
.
1
0
m
E
l
e
c
t
r
i
c
F
e
n
c
e
H
t
=
2
.
6
0
m
D
=
0
.
8
0
m
D
=
1
.
0
0
m
C
o
n
c
r
e
t
e
H
t
=
0
.
1
0
m
E
l
e
c
t
r
i
c
F
e
n
c
e
H
t
=
2
.
6
0
m
4
1
.
5
8
4
1
.
6
0
4
1
.
6
8
4
1
.
6
5
4
1
.
7
3
4
1
.
6
7
4
1
.
5
8
4
1
.
6
5
4
1
.
6
8
4
1
.
5
7
4
1
.
3
8
P
a
l
i
s
a
d
e
F
e
n
c
e
B
/
W
H
t
=
2
.
3
0
m
4
1
.
3
7
4
1
.
1
7
4
1
.
1
1
ABBREVIATIONS
NOTES
REV. DETAILS BY
GRID DATUM
SURVEYED BY: DRAWN BY:
SCALE:
APPROVED BY:
SURVEY DATE:
REV:
DATE
CLIENT:
PROJECT TITLE:
DRAWING TITLE:
DRAWING NUMBER:
SHEET NUMBER:
Structure Overhead
Structure Underground
Building Canopy
Building Overhead
Wall
Structure
Building
Above Ground Pipe
Drainage Channel
Banking
Fence
Surface Edge
Road Kerb Channel
Road Edge
Vegetation Extents
Overhead Pipe
Overhead Electricity
Overhead Telecom
TOPOGRAPHICAL AND UTILITY LEGEND
Scar
Railway Track
Contour Line
220
LEEDS
E-Mail: [email protected] Web site: www.40seven.com
LONDON
01732 7406960113 201 9700
AC Asbestos Cement
ACU Air Conditioning Unit
AD Assumed Direction
AR Assumed Route
AV Air Valve
BB Belisha Beacon
BD Back Drop
BdL Bed Level
BH Borehole
Bk Brick
BL Basement Light
BO Bollard
BOC Bottom of Chamber
BR Brick
BS Bus Stop
BT British Telecom Cover
BTB British Telecom Box
BW Brick Wall
B/W Barbed Wire Fence
Cam Camera
CAT Catenary Level
C/B Close Boarded Fence
CC Control Cabinet
CCTV Close Circuit TV
CH Chainage
ChL Channel Level
CI Cast Iron
C/I Corrugated Iron Fence
CL Cover Level
C/L Chain Link Fence
CO Concrete
CP Catch Pit
CpL Coping Level
CTV Cable TV
CUL Culvert
CW Concrete Wall
DI Ductile Iron
dil Dilapidated
dis Disused
D/S Downstream
DSW Dry Stone Wall
EB Electricity Box
EC Electricity Cover
ED Empty Duct
E/F Electric Fence
EFP Electricity Feeder Pillar
EOT End of Trace
EP Electricity Pole
ER Earth Rod
FC Fuel Cover
FFL Finished Floor Level
FH Fire Hydrant
FO Fibre Optic Cover
FS Flag Staff
G Gully
GPRI Ground Penetrating
Radar Inconclusive
GrL Ground Light
GV Gas Valve
H/R Hand Rail
HV High Voltage
IC Inspection Cover
IL Invert Level
I/R Iron Rail Fence
KO Kerb Outlet
LB Letter Box
LC Lighting Column
LH Lamp Hole
LOR Loss Of Reflection
LOS Loss Of Signal
MB Mooring Bollard
M/C Multiple Cables
MH Manhole Cover
Mkr Marker Post
MP Mile Post/Stone
NFI No Further Information
NM Node Marker
NP Name Plate
NPV No Pipes Visible
OSA Off Survey Area
P Post
PBM Permanent Bench Mark
PE Polyethylene
PGM Permanent Ground
Marker
PL Plastic
P/L Palisade Fence
PM Parking Meter
P/R Post and Rail Fence
PS Poor Signal
PU Pump
PVC Polyvinylchloride
P/W Post and Wire Fence
PWR Power
PZ Piezometer
R Radio
RE Rodding Eye
Ri Riser
RL Roof Level
RP Reflector Post
RS Road Sign
RWP Rain Water Pipe
R/W Retaining Wall
S Stump
SA Survey Abandoned
S/A Soakaway
S/B Safety Barrier
SC Speed Camera
S/F Safety Fence
SI Spun Iron
SL Soffit Level
S/L Street Lighting (Electric)
SP Sign Post
Spr Spring
S/R Steel Railings
SS Sonde Stops
ST Stop Tap
STS Structural Support
Stn Survey Station
SV Sluice Valve
SVP Soil Vent Pipe
SW Stone Wall
Tac Tactile Paving
TBM Temporary Bench Mark
TC Telecom Cover
TCB Telephone Call Box
TCP Telephone Call Post
T/F Temporary Fence
TFR Taken From Records
TH Trial Hole / Pit
ThL Threshold Level
Tk Tank
TOW Top Of Wall
TP Telegraph Pole
TS Traffic Signals
TSC Traffic Signals Cover
U/S Upstream
UTGA Unable to Gain Access
UTL Unable to Locate
UTR Unable to Raise
UTS Unable to Survey
UTT Unable to Trace
VC Vitrified Clay
VDP Vehicle Detector Pad
VP Vent Pipe
VR Vapour Recovery
VTP Vertical Pipe
W Water Cover
WL Water Level
WM Water Meter
W/M Wire Mesh Fence
WO Wash Out
WS Window Sample
WV Wheel Valve
JN BENTLEY LTD
KEIGHLEY ROAD
SKIPTON
BD23 2QR
ROLLS ROYCE
TOPOGRAPHICAL AND GPR
SURVEY
LB / DS VK GJ
1:200 @ A2 07 / 2019
1803_P
2 of 17 A2
ORDNANCE SURVEY
RELATED TO THE OS
ACTIVE STATIONS BY
GPS OBSERVATIONS
ORDNANCE SURVEY
RELATED TO THE OS ACTIVE STATIONS BY
GPS OBSERVATIONS
Unknown
Unknown Route
Located By GPR
R
A
D
I
O
D
=
0
.
8
0
m
D
=
1
.
0
0
m
D
=
1
.
0
0
m
D
=
1
.
1
0
m
O
S
A
D
=
0
.
4
0
m
GP
R S
can 114
Gravel
Gravel
41.56
41.33
P
4
1
.
5
3
4
1
.
5
1
4
1
.
5
3
4
1
.
5
4
4
1
.
6
1
41.564
1
.
5
4
4
1
.
5
4
4
1
.
5
4
4
1
.5
9
41.47
4
1
.
4
7
41.22
41.29
41.16
41.21 41.25
41.1
1
4
1
.
1
9
4
1
.
3
2
G=1.0m
S=1m
4
1
.
6
3
4
1
.
2
7
4
1
.
5
4
4
1
.5
4
4
1
.5
5
4
1
.5
9
41.51
4
1
.4
9
4
1
.4
1
41.12
40.6
5
40.86
41.10
41.2
3
4
1
.
2
1
4
1
.2
4
4
0
.
8
9
4
1
.
1
1
P
a
l
i
s
a
d
e
F
e
n
c
e
B
/
W
H
t
=
2
.
3
0
m
4
1
.
4
2
41.26
41.15
41.31
41.24
41.37
41.53
4
1
.
6
2
4
1
.
5
8
4
1
.
7
1
E
l
e
c
t
r
i
c
F
e
n
c
e
H
t
=
2
.
6
0
m
Concrete Ht =0.10m
C
o
n
c
r
e
t
e
H
t
=
0
.
1
0
m
C/L Ht=2.70m
4
1
.
3
8
4
1
.
3
7
4
1
.
1
7
4
1
.
1
1
ABBREVIATIONS
NOTES
REV. DETAILS BY
GRID DATUM
SURVEYED BY: DRAWN BY:
SCALE:
APPROVED BY:
SURVEY DATE:
REV:
DATE
CLIENT:
PROJECT TITLE:
DRAWING TITLE:
DRAWING NUMBER:
SHEET NUMBER:
Structure Overhead
Structure Underground
Building Canopy
Building Overhead
Wall
Structure
Building
Above Ground Pipe
Drainage Channel
Banking
Fence
Surface Edge
Road Kerb Channel
Road Edge
Vegetation Extents
Overhead Pipe
Overhead Electricity
Overhead Telecom
TOPOGRAPHICAL AND UTILITY LEGEND
Scar
Railway Track
Contour Line
220
LEEDS
E-Mail: [email protected] Web site: www.40seven.com
LONDON
01732 7406960113 201 9700
AC Asbestos Cement
ACU Air Conditioning Unit
AD Assumed Direction
AR Assumed Route
AV Air Valve
BB Belisha Beacon
BD Back Drop
BdL Bed Level
BH Borehole
Bk Brick
BL Basement Light
BO Bollard
BOC Bottom of Chamber
BR Brick
BS Bus Stop
BT British Telecom Cover
BTB British Telecom Box
BW Brick Wall
B/W Barbed Wire Fence
Cam Camera
CAT Catenary Level
C/B Close Boarded Fence
CC Control Cabinet
CCTV Close Circuit TV
CH Chainage
ChL Channel Level
CI Cast Iron
C/I Corrugated Iron Fence
CL Cover Level
C/L Chain Link Fence
CO Concrete
CP Catch Pit
CpL Coping Level
CTV Cable TV
CUL Culvert
CW Concrete Wall
DI Ductile Iron
dil Dilapidated
dis Disused
D/S Downstream
DSW Dry Stone Wall
EB Electricity Box
EC Electricity Cover
ED Empty Duct
E/F Electric Fence
EFP Electricity Feeder Pillar
EOT End of Trace
EP Electricity Pole
ER Earth Rod
FC Fuel Cover
FFL Finished Floor Level
FH Fire Hydrant
FO Fibre Optic Cover
FS Flag Staff
G Gully
GPRI Ground Penetrating
Radar Inconclusive
GrL Ground Light
GV Gas Valve
H/R Hand Rail
HV High Voltage
IC Inspection Cover
IL Invert Level
I/R Iron Rail Fence
KO Kerb Outlet
LB Letter Box
LC Lighting Column
LH Lamp Hole
LOR Loss Of Reflection
LOS Loss Of Signal
MB Mooring Bollard
M/C Multiple Cables
MH Manhole Cover
Mkr Marker Post
MP Mile Post/Stone
NFI No Further Information
NM Node Marker
NP Name Plate
NPV No Pipes Visible
OSA Off Survey Area
P Post
PBM Permanent Bench Mark
PE Polyethylene
PGM Permanent Ground
Marker
PL Plastic
P/L Palisade Fence
PM Parking Meter
P/R Post and Rail Fence
PS Poor Signal
PU Pump
PVC Polyvinylchloride
P/W Post and Wire Fence
PWR Power
PZ Piezometer
R Radio
RE Rodding Eye
Ri Riser
RL Roof Level
RP Reflector Post
RS Road Sign
RWP Rain Water Pipe
R/W Retaining Wall
S Stump
SA Survey Abandoned
S/A Soakaway
S/B Safety Barrier
SC Speed Camera
S/F Safety Fence
SI Spun Iron
SL Soffit Level
S/L Street Lighting (Electric)
SP Sign Post
Spr Spring
S/R Steel Railings
SS Sonde Stops
ST Stop Tap
STS Structural Support
Stn Survey Station
SV Sluice Valve
SVP Soil Vent Pipe
SW Stone Wall
Tac Tactile Paving
TBM Temporary Bench Mark
TC Telecom Cover
TCB Telephone Call Box
TCP Telephone Call Post
T/F Temporary Fence
TFR Taken From Records
TH Trial Hole / Pit
ThL Threshold Level
Tk Tank
TOW Top Of Wall
TP Telegraph Pole
TS Traffic Signals
TSC Traffic Signals Cover
U/S Upstream
UTGA Unable to Gain Access
UTL Unable to Locate
UTR Unable to Raise
UTS Unable to Survey
UTT Unable to Trace
VC Vitrified Clay
VDP Vehicle Detector Pad
VP Vent Pipe
VR Vapour Recovery
VTP Vertical Pipe
W Water Cover
WL Water Level
WM Water Meter
W/M Wire Mesh Fence
WO Wash Out
WS Window Sample
WV Wheel Valve
JN BENTLEY LTD
KEIGHLEY ROAD
SKIPTON
BD23 2QR
ROLLS ROYCE
TOPOGRAPHICAL AND GPR
SURVEY
LB / DS VK GJ
1:200 @ A2 07 / 2019
1803_P
3 of 17 A2
ORDNANCE SURVEY
RELATED TO THE OS
ACTIVE STATIONS BY
GPS OBSERVATIONS
ORDNANCE SURVEY
RELATED TO THE OS ACTIVE STATIONS BY
GPS OBSERVATIONS
Unknown
Unknown Route
Located By GPR
41.74
41.77
41.58
41.49
41.65
41.74
41.81
41.76
4
1
.
5
3
4
1
.
5
1
4
1
.
5
3
G=1.0m
S=1m
4
1
.5
6
4
1
.
6
3
4
1
.
2
7
4
1
.
7
1
4
1
.
8
3
4
1
.
7
8
4
1
.
7
8
4
1
.
6
3
4
1
.
4
8
4
1
.
6
3
4
1
.
7
0
4
1
.
6
4
4
1
.
6
2
C
o
n
c
r
e
t
e
H
t
=
0
.
1
0
m
C
/
L
H
t
=
2
.
7
0
m
ABBREVIATIONS
NOTES
REV. DETAILS BY
GRID DATUM
SURVEYED BY: DRAWN BY:
SCALE:
APPROVED BY:
SURVEY DATE:
REV:
DATE
CLIENT:
PROJECT TITLE:
DRAWING TITLE:
DRAWING NUMBER:
SHEET NUMBER:
Structure Overhead
Structure Underground
Building Canopy
Building Overhead
Wall
Structure
Building
Above Ground Pipe
Drainage Channel
Banking
Fence
Surface Edge
Road Kerb Channel
Road Edge
Vegetation Extents
Overhead Pipe
Overhead Electricity
Overhead Telecom
TOPOGRAPHICAL AND UTILITY LEGEND
Scar
Railway Track
Contour Line
220
LEEDS
E-Mail: [email protected] Web site: www.40seven.com
LONDON
01732 7406960113 201 9700
AC Asbestos Cement
ACU Air Conditioning Unit
AD Assumed Direction
AR Assumed Route
AV Air Valve
BB Belisha Beacon
BD Back Drop
BdL Bed Level
BH Borehole
Bk Brick
BL Basement Light
BO Bollard
BOC Bottom of Chamber
BR Brick
BS Bus Stop
BT British Telecom Cover
BTB British Telecom Box
BW Brick Wall
B/W Barbed Wire Fence
Cam Camera
CAT Catenary Level
C/B Close Boarded Fence
CC Control Cabinet
CCTV Close Circuit TV
CH Chainage
ChL Channel Level
CI Cast Iron
C/I Corrugated Iron Fence
CL Cover Level
C/L Chain Link Fence
CO Concrete
CP Catch Pit
CpL Coping Level
CTV Cable TV
CUL Culvert
CW Concrete Wall
DI Ductile Iron
dil Dilapidated
dis Disused
D/S Downstream
DSW Dry Stone Wall
EB Electricity Box
EC Electricity Cover
ED Empty Duct
E/F Electric Fence
EFP Electricity Feeder Pillar
EOT End of Trace
EP Electricity Pole
ER Earth Rod
FC Fuel Cover
FFL Finished Floor Level
FH Fire Hydrant
FO Fibre Optic Cover
FS Flag Staff
G Gully
GPRI Ground Penetrating
Radar Inconclusive
GrL Ground Light
GV Gas Valve
H/R Hand Rail
HV High Voltage
IC Inspection Cover
IL Invert Level
I/R Iron Rail Fence
KO Kerb Outlet
LB Letter Box
LC Lighting Column
LH Lamp Hole
LOR Loss Of Reflection
LOS Loss Of Signal
MB Mooring Bollard
M/C Multiple Cables
MH Manhole Cover
Mkr Marker Post
MP Mile Post/Stone
NFI No Further Information
NM Node Marker
NP Name Plate
NPV No Pipes Visible
OSA Off Survey Area
P Post
PBM Permanent Bench Mark
PE Polyethylene
PGM Permanent Ground
Marker
PL Plastic
P/L Palisade Fence
PM Parking Meter
P/R Post and Rail Fence
PS Poor Signal
PU Pump
PVC Polyvinylchloride
P/W Post and Wire Fence
PWR Power
PZ Piezometer
R Radio
RE Rodding Eye
Ri Riser
RL Roof Level
RP Reflector Post
RS Road Sign
RWP Rain Water Pipe
R/W Retaining Wall
S Stump
SA Survey Abandoned
S/A Soakaway
S/B Safety Barrier
SC Speed Camera
S/F Safety Fence
SI Spun Iron
SL Soffit Level
S/L Street Lighting (Electric)
SP Sign Post
Spr Spring
S/R Steel Railings
SS Sonde Stops
ST Stop Tap
STS Structural Support
Stn Survey Station
SV Sluice Valve
SVP Soil Vent Pipe
SW Stone Wall
Tac Tactile Paving
TBM Temporary Bench Mark
TC Telecom Cover
TCB Telephone Call Box
TCP Telephone Call Post
T/F Temporary Fence
TFR Taken From Records
TH Trial Hole / Pit
ThL Threshold Level
Tk Tank
TOW Top Of Wall
TP Telegraph Pole
TS Traffic Signals
TSC Traffic Signals Cover
U/S Upstream
UTGA Unable to Gain Access
UTL Unable to Locate
UTR Unable to Raise
UTS Unable to Survey
UTT Unable to Trace
VC Vitrified Clay
VDP Vehicle Detector Pad
VP Vent Pipe
VR Vapour Recovery
VTP Vertical Pipe
W Water Cover
WL Water Level
WM Water Meter
W/M Wire Mesh Fence
WO Wash Out
WS Window Sample
WV Wheel Valve
JN BENTLEY LTD
KEIGHLEY ROAD
SKIPTON
BD23 2QR
ROLLS ROYCE
TOPOGRAPHICAL AND GPR
SURVEY
LB / DS VK GJ
1:200 @ A2 07 / 2019
1803_P
4 of 17 A2
ORDNANCE SURVEY
RELATED TO THE OS
ACTIVE STATIONS BY
GPS OBSERVATIONS
ORDNANCE SURVEY
RELATED TO THE OS ACTIVE STATIONS BY
GPS OBSERVATIONS
Unknown
Unknown Route
Located By GPR
O
S
A
D=
0.60m
D=
0.90m
D
=
0
.6
0
m
Radio
42.37
42.09
42.17
41.89
41.81
41.78
41.74
41.77
C
o
n
c
r
e
t
e
H
t
=
0
.
1
0
m
4
1
.
6
4
4
1
.
6
2
4
1
.
6
9
4
1
.
8
1
4
1
.
9
0
4
2
.
0
3
4
2
.
2
5
4
2
.
2
6
4
2
.
3
1
4
2
.
3
6
C
/
L
H
t
=
2
.
7
0
m
4
2
.
1
8
4
2
.
1
5
4
2
.
0
6
4
1
.
9
2
4
2
.
0
4
H
e
r
a
s
F
e
n
c
e
H
t
=
2
.
0
0
m
ABBREVIATIONS
NOTES
REV. DETAILS BY
GRID DATUM
SURVEYED BY: DRAWN BY:
SCALE:
APPROVED BY:
SURVEY DATE:
REV:
DATE
CLIENT:
PROJECT TITLE:
DRAWING TITLE:
DRAWING NUMBER:
SHEET NUMBER:
Structure Overhead
Structure Underground
Building Canopy
Building Overhead
Wall
Structure
Building
Above Ground Pipe
Drainage Channel
Banking
Fence
Surface Edge
Road Kerb Channel
Road Edge
Vegetation Extents
Overhead Pipe
Overhead Electricity
Overhead Telecom
TOPOGRAPHICAL AND UTILITY LEGEND
Scar
Railway Track
Contour Line
220
LEEDS
E-Mail: [email protected] Web site: www.40seven.com
LONDON
01732 7406960113 201 9700
AC Asbestos Cement
ACU Air Conditioning Unit
AD Assumed Direction
AR Assumed Route
AV Air Valve
BB Belisha Beacon
BD Back Drop
BdL Bed Level
BH Borehole
Bk Brick
BL Basement Light
BO Bollard
BOC Bottom of Chamber
BR Brick
BS Bus Stop
BT British Telecom Cover
BTB British Telecom Box
BW Brick Wall
B/W Barbed Wire Fence
Cam Camera
CAT Catenary Level
C/B Close Boarded Fence
CC Control Cabinet
CCTV Close Circuit TV
CH Chainage
ChL Channel Level
CI Cast Iron
C/I Corrugated Iron Fence
CL Cover Level
C/L Chain Link Fence
CO Concrete
CP Catch Pit
CpL Coping Level
CTV Cable TV
CUL Culvert
CW Concrete Wall
DI Ductile Iron
dil Dilapidated
dis Disused
D/S Downstream
DSW Dry Stone Wall
EB Electricity Box
EC Electricity Cover
ED Empty Duct
E/F Electric Fence
EFP Electricity Feeder Pillar
EOT End of Trace
EP Electricity Pole
ER Earth Rod
FC Fuel Cover
FFL Finished Floor Level
FH Fire Hydrant
FO Fibre Optic Cover
FS Flag Staff
G Gully
GPRI Ground Penetrating
Radar Inconclusive
GrL Ground Light
GV Gas Valve
H/R Hand Rail
HV High Voltage
IC Inspection Cover
IL Invert Level
I/R Iron Rail Fence
KO Kerb Outlet
LB Letter Box
LC Lighting Column
LH Lamp Hole
LOR Loss Of Reflection
LOS Loss Of Signal
MB Mooring Bollard
M/C Multiple Cables
MH Manhole Cover
Mkr Marker Post
MP Mile Post/Stone
NFI No Further Information
NM Node Marker
NP Name Plate
NPV No Pipes Visible
OSA Off Survey Area
P Post
PBM Permanent Bench Mark
PE Polyethylene
PGM Permanent Ground
Marker
PL Plastic
P/L Palisade Fence
PM Parking Meter
P/R Post and Rail Fence
PS Poor Signal
PU Pump
PVC Polyvinylchloride
P/W Post and Wire Fence
PWR Power
PZ Piezometer
R Radio
RE Rodding Eye
Ri Riser
RL Roof Level
RP Reflector Post
RS Road Sign
RWP Rain Water Pipe
R/W Retaining Wall
S Stump
SA Survey Abandoned
S/A Soakaway
S/B Safety Barrier
SC Speed Camera
S/F Safety Fence
SI Spun Iron
SL Soffit Level
S/L Street Lighting (Electric)
SP Sign Post
Spr Spring
S/R Steel Railings
SS Sonde Stops
ST Stop Tap
STS Structural Support
Stn Survey Station
SV Sluice Valve
SVP Soil Vent Pipe
SW Stone Wall
Tac Tactile Paving
TBM Temporary Bench Mark
TC Telecom Cover
TCB Telephone Call Box
TCP Telephone Call Post
T/F Temporary Fence
TFR Taken From Records
TH Trial Hole / Pit
ThL Threshold Level
Tk Tank
TOW Top Of Wall
TP Telegraph Pole
TS Traffic Signals
TSC Traffic Signals Cover
U/S Upstream
UTGA Unable to Gain Access
UTL Unable to Locate
UTR Unable to Raise
UTS Unable to Survey
UTT Unable to Trace
VC Vitrified Clay
VDP Vehicle Detector Pad
VP Vent Pipe
VR Vapour Recovery
VTP Vertical Pipe
W Water Cover
WL Water Level
WM Water Meter
W/M Wire Mesh Fence
WO Wash Out
WS Window Sample
WV Wheel Valve
JN BENTLEY LTD
KEIGHLEY ROAD
SKIPTON
BD23 2QR
ROLLS ROYCE
TOPOGRAPHICAL AND GPR
SURVEY
LB / DS VK GJ
1:200 @ A2 07 / 2019
1803_P
5 of 17 A2
ORDNANCE SURVEY
RELATED TO THE OS
ACTIVE STATIONS BY
GPS OBSERVATIONS
ORDNANCE SURVEY
RELATED TO THE OS ACTIVE STATIONS BY
GPS OBSERVATIONS
Unknown
Unknown Route
Located By GPR
O
S
A
D=
0.60m
D=
0.90m
O
SA
D=
1.60m
D=
1.30m
D=
1.30m
D
=
0
.6
0
m
R
adio
Radio
G
P
R
S
c
a
n
8
0
1
42.25
42.22
42.13
42.06
42.00
42.32
42.48
42.37
42.09
42.17
4
2
.
2
6
4
2
.
3
1
4
2
.
3
6
4
2
.
4
1
4
2
.
1
4
4
2
.
1
0
4
2
.
1
9
4
2
.
2
0
4
2
.
2
9
4
2
.
3
7
ABBREVIATIONS
NOTES
REV. DETAILS BY
GRID DATUM
SURVEYED BY: DRAWN BY:
SCALE:
APPROVED BY:
SURVEY DATE:
REV:
DATE
CLIENT:
PROJECT TITLE:
DRAWING TITLE:
DRAWING NUMBER:
SHEET NUMBER:
Structure Overhead
Structure Underground
Building Canopy
Building Overhead
Wall
Structure
Building
Above Ground Pipe
Drainage Channel
Banking
Fence
Surface Edge
Road Kerb Channel
Road Edge
Vegetation Extents
Overhead Pipe
Overhead Electricity
Overhead Telecom
TOPOGRAPHICAL AND UTILITY LEGEND
Scar
Railway Track
Contour Line
220
LEEDS
E-Mail: [email protected] Web site: www.40seven.com
LONDON
01732 7406960113 201 9700
AC Asbestos Cement
ACU Air Conditioning Unit
AD Assumed Direction
AR Assumed Route
AV Air Valve
BB Belisha Beacon
BD Back Drop
BdL Bed Level
BH Borehole
Bk Brick
BL Basement Light
BO Bollard
BOC Bottom of Chamber
BR Brick
BS Bus Stop
BT British Telecom Cover
BTB British Telecom Box
BW Brick Wall
B/W Barbed Wire Fence
Cam Camera
CAT Catenary Level
C/B Close Boarded Fence
CC Control Cabinet
CCTV Close Circuit TV
CH Chainage
ChL Channel Level
CI Cast Iron
C/I Corrugated Iron Fence
CL Cover Level
C/L Chain Link Fence
CO Concrete
CP Catch Pit
CpL Coping Level
CTV Cable TV
CUL Culvert
CW Concrete Wall
DI Ductile Iron
dil Dilapidated
dis Disused
D/S Downstream
DSW Dry Stone Wall
EB Electricity Box
EC Electricity Cover
ED Empty Duct
E/F Electric Fence
EFP Electricity Feeder Pillar
EOT End of Trace
EP Electricity Pole
ER Earth Rod
FC Fuel Cover
FFL Finished Floor Level
FH Fire Hydrant
FO Fibre Optic Cover
FS Flag Staff
G Gully
GPRI Ground Penetrating
Radar Inconclusive
GrL Ground Light
GV Gas Valve
H/R Hand Rail
HV High Voltage
IC Inspection Cover
IL Invert Level
I/R Iron Rail Fence
KO Kerb Outlet
LB Letter Box
LC Lighting Column
LH Lamp Hole
LOR Loss Of Reflection
LOS Loss Of Signal
MB Mooring Bollard
M/C Multiple Cables
MH Manhole Cover
Mkr Marker Post
MP Mile Post/Stone
NFI No Further Information
NM Node Marker
NP Name Plate
NPV No Pipes Visible
OSA Off Survey Area
P Post
PBM Permanent Bench Mark
PE Polyethylene
PGM Permanent Ground
Marker
PL Plastic
P/L Palisade Fence
PM Parking Meter
P/R Post and Rail Fence
PS Poor Signal
PU Pump
PVC Polyvinylchloride
P/W Post and Wire Fence
PWR Power
PZ Piezometer
R Radio
RE Rodding Eye
Ri Riser
RL Roof Level
RP Reflector Post
RS Road Sign
RWP Rain Water Pipe
R/W Retaining Wall
S Stump
SA Survey Abandoned
S/A Soakaway
S/B Safety Barrier
SC Speed Camera
S/F Safety Fence
SI Spun Iron
SL Soffit Level
S/L Street Lighting (Electric)
SP Sign Post
Spr Spring
S/R Steel Railings
SS Sonde Stops
ST Stop Tap
STS Structural Support
Stn Survey Station
SV Sluice Valve
SVP Soil Vent Pipe
SW Stone Wall
Tac Tactile Paving
TBM Temporary Bench Mark
TC Telecom Cover
TCB Telephone Call Box
TCP Telephone Call Post
T/F Temporary Fence
TFR Taken From Records
TH Trial Hole / Pit
ThL Threshold Level
Tk Tank
TOW Top Of Wall
TP Telegraph Pole
TS Traffic Signals
TSC Traffic Signals Cover
U/S Upstream
UTGA Unable to Gain Access
UTL Unable to Locate
UTR Unable to Raise
UTS Unable to Survey
UTT Unable to Trace
VC Vitrified Clay
VDP Vehicle Detector Pad
VP Vent Pipe
VR Vapour Recovery
VTP Vertical Pipe
W Water Cover
WL Water Level
WM Water Meter
W/M Wire Mesh Fence
WO Wash Out
WS Window Sample
WV Wheel Valve
JN BENTLEY LTD
KEIGHLEY ROAD
SKIPTON
BD23 2QR
ROLLS ROYCE
TOPOGRAPHICAL AND GPR
SURVEY
LB / DS VK GJ
1:200 @ A2 07 / 2019
1803_P
6 of 17 A2
ORDNANCE SURVEY
RELATED TO THE OS
ACTIVE STATIONS BY
GPS OBSERVATIONS
ORDNANCE SURVEY
RELATED TO THE OS ACTIVE STATIONS BY
GPS OBSERVATIONS
Unknown
Unknown Route
Located By GPR
G
P
R
S
c
a
n
7
0
7
42.61
42.52
42.45
42.25
42.22
42.53
42.60
42.64
42.63
42.64
42.64
42.72
4
2
.
7
6
4
2
.
7
7
4
2
.
7
2
4
2
.
2
0
4
2
.
2
9
4
2
.
3
7
4
2
.
4
4
4
2
.
6
1
4
2
.
6
8
4
2
.
6
3
4
2
.
6
6
4
2
.
6
4
4
2
.
5
8
4
2
.
5
2
4
2
.
4
9
C
/
L
H
t
=
2
.
7
0
m
C
o
n
c
r
e
t
e
H
t
=
0
.
1
0
m
42.66
4
2
.
6
8
4
2
.
7
2
4
2
.
7
1
4
2
.
7
7
4
2
.
7
2
4
2
.
7
4
H
e
r
a
s
F
e
n
c
e
H
t
=
2
.
0
0
m
ABBREVIATIONS
NOTES
REV. DETAILS BY
GRID DATUM
SURVEYED BY: DRAWN BY:
SCALE:
APPROVED BY:
SURVEY DATE:
REV:
DATE
CLIENT:
PROJECT TITLE:
DRAWING TITLE:
DRAWING NUMBER:
SHEET NUMBER:
Structure Overhead
Structure Underground
Building Canopy
Building Overhead
Wall
Structure
Building
Above Ground Pipe
Drainage Channel
Banking
Fence
Surface Edge
Road Kerb Channel
Road Edge
Vegetation Extents
Overhead Pipe
Overhead Electricity
Overhead Telecom
TOPOGRAPHICAL AND UTILITY LEGEND
Scar
Railway Track
Contour Line
220
LEEDS
E-Mail: [email protected] Web site: www.40seven.com
LONDON
01732 7406960113 201 9700
AC Asbestos Cement
ACU Air Conditioning Unit
AD Assumed Direction
AR Assumed Route
AV Air Valve
BB Belisha Beacon
BD Back Drop
BdL Bed Level
BH Borehole
Bk Brick
BL Basement Light
BO Bollard
BOC Bottom of Chamber
BR Brick
BS Bus Stop
BT British Telecom Cover
BTB British Telecom Box
BW Brick Wall
B/W Barbed Wire Fence
Cam Camera
CAT Catenary Level
C/B Close Boarded Fence
CC Control Cabinet
CCTV Close Circuit TV
CH Chainage
ChL Channel Level
CI Cast Iron
C/I Corrugated Iron Fence
CL Cover Level
C/L Chain Link Fence
CO Concrete
CP Catch Pit
CpL Coping Level
CTV Cable TV
CUL Culvert
CW Concrete Wall
DI Ductile Iron
dil Dilapidated
dis Disused
D/S Downstream
DSW Dry Stone Wall
EB Electricity Box
EC Electricity Cover
ED Empty Duct
E/F Electric Fence
EFP Electricity Feeder Pillar
EOT End of Trace
EP Electricity Pole
ER Earth Rod
FC Fuel Cover
FFL Finished Floor Level
FH Fire Hydrant
FO Fibre Optic Cover
FS Flag Staff
G Gully
GPRI Ground Penetrating
Radar Inconclusive
GrL Ground Light
GV Gas Valve
H/R Hand Rail
HV High Voltage
IC Inspection Cover
IL Invert Level
I/R Iron Rail Fence
KO Kerb Outlet
LB Letter Box
LC Lighting Column
LH Lamp Hole
LOR Loss Of Reflection
LOS Loss Of Signal
MB Mooring Bollard
M/C Multiple Cables
MH Manhole Cover
Mkr Marker Post
MP Mile Post/Stone
NFI No Further Information
NM Node Marker
NP Name Plate
NPV No Pipes Visible
OSA Off Survey Area
P Post
PBM Permanent Bench Mark
PE Polyethylene
PGM Permanent Ground
Marker
PL Plastic
P/L Palisade Fence
PM Parking Meter
P/R Post and Rail Fence
PS Poor Signal
PU Pump
PVC Polyvinylchloride
P/W Post and Wire Fence
PWR Power
PZ Piezometer
R Radio
RE Rodding Eye
Ri Riser
RL Roof Level
RP Reflector Post
RS Road Sign
RWP Rain Water Pipe
R/W Retaining Wall
S Stump
SA Survey Abandoned
S/A Soakaway
S/B Safety Barrier
SC Speed Camera
S/F Safety Fence
SI Spun Iron
SL Soffit Level
S/L Street Lighting (Electric)
SP Sign Post
Spr Spring
S/R Steel Railings
SS Sonde Stops
ST Stop Tap
STS Structural Support
Stn Survey Station
SV Sluice Valve
SVP Soil Vent Pipe
SW Stone Wall
Tac Tactile Paving
TBM Temporary Bench Mark
TC Telecom Cover
TCB Telephone Call Box
TCP Telephone Call Post
T/F Temporary Fence
TFR Taken From Records
TH Trial Hole / Pit
ThL Threshold Level
Tk Tank
TOW Top Of Wall
TP Telegraph Pole
TS Traffic Signals
TSC Traffic Signals Cover
U/S Upstream
UTGA Unable to Gain Access
UTL Unable to Locate
UTR Unable to Raise
UTS Unable to Survey
UTT Unable to Trace
VC Vitrified Clay
VDP Vehicle Detector Pad
VP Vent Pipe
VR Vapour Recovery
VTP Vertical Pipe
W Water Cover
WL Water Level
WM Water Meter
W/M Wire Mesh Fence
WO Wash Out
WS Window Sample
WV Wheel Valve
JN BENTLEY LTD
KEIGHLEY ROAD
SKIPTON
BD23 2QR
ROLLS ROYCE
TOPOGRAPHICAL AND GPR
SURVEY
LB / DS VK GJ
1:200 @ A2 07 / 2019
1803_P
7 of 17 A2
ORDNANCE SURVEY
RELATED TO THE OS
ACTIVE STATIONS BY
GPS OBSERVATIONS
ORDNANCE SURVEY
RELATED TO THE OS ACTIVE STATIONS BY
GPS OBSERVATIONS
Unknown
Unknown Route
Located By GPR
G
P
R
S
c
a
n
0
1
5
BO
42.59
42.50
42.52
42.55
42.48
42.53
42.50
4
2
.
4
9
4
2
.
5
5
4
2
.
5
2
4
2
.
5
3
4
2
.
5
4
4
2
.
5
7
4
2
.
4
9
4
2
.
5
2
4
2
.
4
9
4
2
.
5
9
C
o
n
c
r
e
t
e
H
t
=
0
.
1
0
m
C
/
L
H
t
=
2
.
7
0
m
42.66
ABBREVIATIONS
NOTES
REV. DETAILS BY
GRID DATUM
SURVEYED BY: DRAWN BY:
SCALE:
APPROVED BY:
SURVEY DATE:
REV:
DATE
CLIENT:
PROJECT TITLE:
DRAWING TITLE:
DRAWING NUMBER:
SHEET NUMBER:
Structure Overhead
Structure Underground
Building Canopy
Building Overhead
Wall
Structure
Building
Above Ground Pipe
Drainage Channel
Banking
Fence
Surface Edge
Road Kerb Channel
Road Edge
Vegetation Extents
Overhead Pipe
Overhead Electricity
Overhead Telecom
TOPOGRAPHICAL AND UTILITY LEGEND
Scar
Railway Track
Contour Line
220
LEEDS
E-Mail: [email protected] Web site: www.40seven.com
LONDON
01732 7406960113 201 9700
AC Asbestos Cement
ACU Air Conditioning Unit
AD Assumed Direction
AR Assumed Route
AV Air Valve
BB Belisha Beacon
BD Back Drop
BdL Bed Level
BH Borehole
Bk Brick
BL Basement Light
BO Bollard
BOC Bottom of Chamber
BR Brick
BS Bus Stop
BT British Telecom Cover
BTB British Telecom Box
BW Brick Wall
B/W Barbed Wire Fence
Cam Camera
CAT Catenary Level
C/B Close Boarded Fence
CC Control Cabinet
CCTV Close Circuit TV
CH Chainage
ChL Channel Level
CI Cast Iron
C/I Corrugated Iron Fence
CL Cover Level
C/L Chain Link Fence
CO Concrete
CP Catch Pit
CpL Coping Level
CTV Cable TV
CUL Culvert
CW Concrete Wall
DI Ductile Iron
dil Dilapidated
dis Disused
D/S Downstream
DSW Dry Stone Wall
EB Electricity Box
EC Electricity Cover
ED Empty Duct
E/F Electric Fence
EFP Electricity Feeder Pillar
EOT End of Trace
EP Electricity Pole
ER Earth Rod
FC Fuel Cover
FFL Finished Floor Level
FH Fire Hydrant
FO Fibre Optic Cover
FS Flag Staff
G Gully
GPRI Ground Penetrating
Radar Inconclusive
GrL Ground Light
GV Gas Valve
H/R Hand Rail
HV High Voltage
IC Inspection Cover
IL Invert Level
I/R Iron Rail Fence
KO Kerb Outlet
LB Letter Box
LC Lighting Column
LH Lamp Hole
LOR Loss Of Reflection
LOS Loss Of Signal
MB Mooring Bollard
M/C Multiple Cables
MH Manhole Cover
Mkr Marker Post
MP Mile Post/Stone
NFI No Further Information
NM Node Marker
NP Name Plate
NPV No Pipes Visible
OSA Off Survey Area
P Post
PBM Permanent Bench Mark
PE Polyethylene
PGM Permanent Ground
Marker
PL Plastic
P/L Palisade Fence
PM Parking Meter
P/R Post and Rail Fence
PS Poor Signal
PU Pump
PVC Polyvinylchloride
P/W Post and Wire Fence
PWR Power
PZ Piezometer
R Radio
RE Rodding Eye
Ri Riser
RL Roof Level
RP Reflector Post
RS Road Sign
RWP Rain Water Pipe
R/W Retaining Wall
S Stump
SA Survey Abandoned
S/A Soakaway
S/B Safety Barrier
SC Speed Camera
S/F Safety Fence
SI Spun Iron
SL Soffit Level
S/L Street Lighting (Electric)
SP Sign Post
Spr Spring
S/R Steel Railings
SS Sonde Stops
ST Stop Tap
STS Structural Support
Stn Survey Station
SV Sluice Valve
SVP Soil Vent Pipe
SW Stone Wall
Tac Tactile Paving
TBM Temporary Bench Mark
TC Telecom Cover
TCB Telephone Call Box
TCP Telephone Call Post
T/F Temporary Fence
TFR Taken From Records
TH Trial Hole / Pit
ThL Threshold Level
Tk Tank
TOW Top Of Wall
TP Telegraph Pole
TS Traffic Signals
TSC Traffic Signals Cover
U/S Upstream
UTGA Unable to Gain Access
UTL Unable to Locate
UTR Unable to Raise
UTS Unable to Survey
UTT Unable to Trace
VC Vitrified Clay
VDP Vehicle Detector Pad
VP Vent Pipe
VR Vapour Recovery
VTP Vertical Pipe
W Water Cover
WL Water Level
WM Water Meter
W/M Wire Mesh Fence
WO Wash Out
WS Window Sample
WV Wheel Valve
JN BENTLEY LTD
KEIGHLEY ROAD
SKIPTON
BD23 2QR
ROLLS ROYCE
TOPOGRAPHICAL AND GPR
SURVEY
LB / DS VK GJ
1:200 @ A2 07 / 2019
1803_P
8 of 17 A2
ORDNANCE SURVEY
RELATED TO THE OS
ACTIVE STATIONS BY
GPS OBSERVATIONS
ORDNANCE SURVEY
RELATED TO THE OS ACTIVE STATIONS BY
GPS OBSERVATIONS
Unknown
Unknown Route
Located By GPR
42.69
42.65
42.65
42.76
42.70
42.63
42.65
42.59
4
2
.
4
9
4
2
.
5
9
4
2
.
5
8
4
2
.
6
3
4
2
.
6
5
4
2
.
6
2
4
2
.
5
6
4
2
.
5
7
4
2
.
5
5
ABBREVIATIONS
NOTES
REV. DETAILS BY
GRID DATUM
SURVEYED BY: DRAWN BY:
SCALE:
APPROVED BY:
SURVEY DATE:
REV:
DATE
CLIENT:
PROJECT TITLE:
DRAWING TITLE:
DRAWING NUMBER:
SHEET NUMBER:
Structure Overhead
Structure Underground
Building Canopy
Building Overhead
Wall
Structure
Building
Above Ground Pipe
Drainage Channel
Banking
Fence
Surface Edge
Road Kerb Channel
Road Edge
Vegetation Extents
Overhead Pipe
Overhead Electricity
Overhead Telecom
TOPOGRAPHICAL AND UTILITY LEGEND
Scar
Railway Track
Contour Line
220
LEEDS
E-Mail: [email protected] Web site: www.40seven.com
LONDON
01732 7406960113 201 9700
AC Asbestos Cement
ACU Air Conditioning Unit
AD Assumed Direction
AR Assumed Route
AV Air Valve
BB Belisha Beacon
BD Back Drop
BdL Bed Level
BH Borehole
Bk Brick
BL Basement Light
BO Bollard
BOC Bottom of Chamber
BR Brick
BS Bus Stop
BT British Telecom Cover
BTB British Telecom Box
BW Brick Wall
B/W Barbed Wire Fence
Cam Camera
CAT Catenary Level
C/B Close Boarded Fence
CC Control Cabinet
CCTV Close Circuit TV
CH Chainage
ChL Channel Level
CI Cast Iron
C/I Corrugated Iron Fence
CL Cover Level
C/L Chain Link Fence
CO Concrete
CP Catch Pit
CpL Coping Level
CTV Cable TV
CUL Culvert
CW Concrete Wall
DI Ductile Iron
dil Dilapidated
dis Disused
D/S Downstream
DSW Dry Stone Wall
EB Electricity Box
EC Electricity Cover
ED Empty Duct
E/F Electric Fence
EFP Electricity Feeder Pillar
EOT End of Trace
EP Electricity Pole
ER Earth Rod
FC Fuel Cover
FFL Finished Floor Level
FH Fire Hydrant
FO Fibre Optic Cover
FS Flag Staff
G Gully
GPRI Ground Penetrating
Radar Inconclusive
GrL Ground Light
GV Gas Valve
H/R Hand Rail
HV High Voltage
IC Inspection Cover
IL Invert Level
I/R Iron Rail Fence
KO Kerb Outlet
LB Letter Box
LC Lighting Column
LH Lamp Hole
LOR Loss Of Reflection
LOS Loss Of Signal
MB Mooring Bollard
M/C Multiple Cables
MH Manhole Cover
Mkr Marker Post
MP Mile Post/Stone
NFI No Further Information
NM Node Marker
NP Name Plate
NPV No Pipes Visible
OSA Off Survey Area
P Post
PBM Permanent Bench Mark
PE Polyethylene
PGM Permanent Ground
Marker
PL Plastic
P/L Palisade Fence
PM Parking Meter
P/R Post and Rail Fence
PS Poor Signal
PU Pump
PVC Polyvinylchloride
P/W Post and Wire Fence
PWR Power
PZ Piezometer
R Radio
RE Rodding Eye
Ri Riser
RL Roof Level
RP Reflector Post
RS Road Sign
RWP Rain Water Pipe
R/W Retaining Wall
S Stump
SA Survey Abandoned
S/A Soakaway
S/B Safety Barrier
SC Speed Camera
S/F Safety Fence
SI Spun Iron
SL Soffit Level
S/L Street Lighting (Electric)
SP Sign Post
Spr Spring
S/R Steel Railings
SS Sonde Stops
ST Stop Tap
STS Structural Support
Stn Survey Station
SV Sluice Valve
SVP Soil Vent Pipe
SW Stone Wall
Tac Tactile Paving
TBM Temporary Bench Mark
TC Telecom Cover
TCB Telephone Call Box
TCP Telephone Call Post
T/F Temporary Fence
TFR Taken From Records
TH Trial Hole / Pit
ThL Threshold Level
Tk Tank
TOW Top Of Wall
TP Telegraph Pole
TS Traffic Signals
TSC Traffic Signals Cover
U/S Upstream
UTGA Unable to Gain Access
UTL Unable to Locate
UTR Unable to Raise
UTS Unable to Survey
UTT Unable to Trace
VC Vitrified Clay
VDP Vehicle Detector Pad
VP Vent Pipe
VR Vapour Recovery
VTP Vertical Pipe
W Water Cover
WL Water Level
WM Water Meter
W/M Wire Mesh Fence
WO Wash Out
WS Window Sample
WV Wheel Valve
JN BENTLEY LTD
KEIGHLEY ROAD
SKIPTON
BD23 2QR
ROLLS ROYCE
TOPOGRAPHICAL AND GPR
SURVEY
LB / DS VK GJ
1:200 @ A2 07 / 2019
1803_P
9 of 17 A2
ORDNANCE SURVEY
RELATED TO THE OS
ACTIVE STATIONS BY
GPS OBSERVATIONS
ORDNANCE SURVEY
RELATED TO THE OS ACTIVE STATIONS BY
GPS OBSERVATIONS
Unknown
Unknown Route
Located By GPR
O
S
A
D
=
0
.
2
0
m
D
=
0
.
2
0
m
D
=
0
.
1
0
m
D
=
0
.
2
0
m
O
S
A
L
O
R
L
O
R
D
=
0
.
4
0
m
O
S
A
D
=
0
.
4
0
m
O
S
A
G
P
R
S
c
a
n
9
0
5
42.87
42.80
42.68
42.64
42.71
42.54
42.51
42.66
42.69
42.65
C
o
n
c
r
e
t
e
H
t
=
0
.
2
0
m
C
o
n
c
r
e
t
e
H
t
=
0
.
1
0
m
4
2
.
5
7
4
2
.
5
5
4
2
.
5
9
4
2
.
5
3
4
2
.
4
7
4
2
.
4
8
4
2
.
5
5
4
2
.
6
8
4
2
.
6
4
4
2
.
6
6
4
2
.
6
6
ABBREVIATIONS
NOTES
REV. DETAILS BY
GRID DATUM
SURVEYED BY: DRAWN BY:
SCALE:
APPROVED BY:
SURVEY DATE:
REV:
DATE
CLIENT:
PROJECT TITLE:
DRAWING TITLE:
DRAWING NUMBER:
SHEET NUMBER:
Structure Overhead
Structure Underground
Building Canopy
Building Overhead
Wall
Structure
Building
Above Ground Pipe
Drainage Channel
Banking
Fence
Surface Edge
Road Kerb Channel
Road Edge
Vegetation Extents
Overhead Pipe
Overhead Electricity
Overhead Telecom
TOPOGRAPHICAL AND UTILITY LEGEND
Scar
Railway Track
Contour Line
220
LEEDS
E-Mail: [email protected] Web site: www.40seven.com
LONDON
01732 7406960113 201 9700
AC Asbestos Cement
ACU Air Conditioning Unit
AD Assumed Direction
AR Assumed Route
AV Air Valve
BB Belisha Beacon
BD Back Drop
BdL Bed Level
BH Borehole
Bk Brick
BL Basement Light
BO Bollard
BOC Bottom of Chamber
BR Brick
BS Bus Stop
BT British Telecom Cover
BTB British Telecom Box
BW Brick Wall
B/W Barbed Wire Fence
Cam Camera
CAT Catenary Level
C/B Close Boarded Fence
CC Control Cabinet
CCTV Close Circuit TV
CH Chainage
ChL Channel Level
CI Cast Iron
C/I Corrugated Iron Fence
CL Cover Level
C/L Chain Link Fence
CO Concrete
CP Catch Pit
CpL Coping Level
CTV Cable TV
CUL Culvert
CW Concrete Wall
DI Ductile Iron
dil Dilapidated
dis Disused
D/S Downstream
DSW Dry Stone Wall
EB Electricity Box
EC Electricity Cover
ED Empty Duct
E/F Electric Fence
EFP Electricity Feeder Pillar
EOT End of Trace
EP Electricity Pole
ER Earth Rod
FC Fuel Cover
FFL Finished Floor Level
FH Fire Hydrant
FO Fibre Optic Cover
FS Flag Staff
G Gully
GPRI Ground Penetrating
Radar Inconclusive
GrL Ground Light
GV Gas Valve
H/R Hand Rail
HV High Voltage
IC Inspection Cover
IL Invert Level
I/R Iron Rail Fence
KO Kerb Outlet
LB Letter Box
LC Lighting Column
LH Lamp Hole
LOR Loss Of Reflection
LOS Loss Of Signal
MB Mooring Bollard
M/C Multiple Cables
MH Manhole Cover
Mkr Marker Post
MP Mile Post/Stone
NFI No Further Information
NM Node Marker
NP Name Plate
NPV No Pipes Visible
OSA Off Survey Area
P Post
PBM Permanent Bench Mark
PE Polyethylene
PGM Permanent Ground
Marker
PL Plastic
P/L Palisade Fence
PM Parking Meter
P/R Post and Rail Fence
PS Poor Signal
PU Pump
PVC Polyvinylchloride
P/W Post and Wire Fence
PWR Power
PZ Piezometer
R Radio
RE Rodding Eye
Ri Riser
RL Roof Level
RP Reflector Post
RS Road Sign
RWP Rain Water Pipe
R/W Retaining Wall
S Stump
SA Survey Abandoned
S/A Soakaway
S/B Safety Barrier
SC Speed Camera
S/F Safety Fence
SI Spun Iron
SL Soffit Level
S/L Street Lighting (Electric)
SP Sign Post
Spr Spring
S/R Steel Railings
SS Sonde Stops
ST Stop Tap
STS Structural Support
Stn Survey Station
SV Sluice Valve
SVP Soil Vent Pipe
SW Stone Wall
Tac Tactile Paving
TBM Temporary Bench Mark
TC Telecom Cover
TCB Telephone Call Box
TCP Telephone Call Post
T/F Temporary Fence
TFR Taken From Records
TH Trial Hole / Pit
ThL Threshold Level
Tk Tank
TOW Top Of Wall
TP Telegraph Pole
TS Traffic Signals
TSC Traffic Signals Cover
U/S Upstream
UTGA Unable to Gain Access
UTL Unable to Locate
UTR Unable to Raise
UTS Unable to Survey
UTT Unable to Trace
VC Vitrified Clay
VDP Vehicle Detector Pad
VP Vent Pipe
VR Vapour Recovery
VTP Vertical Pipe
W Water Cover
WL Water Level
WM Water Meter
W/M Wire Mesh Fence
WO Wash Out
WS Window Sample
WV Wheel Valve
JN BENTLEY LTD
KEIGHLEY ROAD
SKIPTON
BD23 2QR
ROLLS ROYCE
TOPOGRAPHICAL AND GPR
SURVEY
LB / DS VK GJ
1:200 @ A2 07 / 2019
1803_P
10 of 17 A2
ORDNANCE SURVEY
RELATED TO THE OS
ACTIVE STATIONS BY
GPS OBSERVATIONS
ORDNANCE SURVEY
RELATED TO THE OS ACTIVE STATIONS BY
GPS OBSERVATIONS
Unknown
Unknown Route
Located By GPR
O
S
A
D
=
0
.
2
0
m
D
=
0
.
2
0
m
D
=
0
.
1
0
m
D
=
0
.
2
0
m
O
S
A
D
=
1
.
0
0
m
D
=
1
.
0
0
m
L
O
R
L
O
R
D
=
0
.
4
0
m
O
S
A
D
=
0
.
4
0
m
O
S
A
O
S
A
G
P
R
S
c
a
n
9
0
5
G
P
R
S
c
a
n
9
5
1
43.48
43.42
43.58
43.53
43.14
42.87
42.80
42.68
4
3
.
6
2
4
3
.
6
7
C
o
n
c
r
e
t
e
H
t
=
0
.
1
0
m
4
2
.
6
4
4
2
.
6
6
4
2
.
6
6
4
2
.
7
9
4
2
.
8
2
4
3
.
1
9
4
3
.
3
5
C
/
L
H
t
=
2
.
4
0
m
C
o
n
c
r
e
t
e
H
t
=
0
.
1
0
m
4
3
.
3
1
4
3
.
2
1
4
3
.
3
3
4
3
.
4
9
4
3
.
4
4
4
3
.
6
9
4
3
.
7
5
ABBREVIATIONS
NOTES
REV. DETAILS BY
GRID DATUM
SURVEYED BY: DRAWN BY:
SCALE:
APPROVED BY:
SURVEY DATE:
REV:
DATE
CLIENT:
PROJECT TITLE:
DRAWING TITLE:
DRAWING NUMBER:
SHEET NUMBER:
Structure Overhead
Structure Underground
Building Canopy
Building Overhead
Wall
Structure
Building
Above Ground Pipe
Drainage Channel
Banking
Fence
Surface Edge
Road Kerb Channel
Road Edge
Vegetation Extents
Overhead Pipe
Overhead Electricity
Overhead Telecom
TOPOGRAPHICAL AND UTILITY LEGEND
Scar
Railway Track
Contour Line
220
LEEDS
E-Mail: [email protected] Web site: www.40seven.com
LONDON
01732 7406960113 201 9700
AC Asbestos Cement
ACU Air Conditioning Unit
AD Assumed Direction
AR Assumed Route
AV Air Valve
BB Belisha Beacon
BD Back Drop
BdL Bed Level
BH Borehole
Bk Brick
BL Basement Light
BO Bollard
BOC Bottom of Chamber
BR Brick
BS Bus Stop
BT British Telecom Cover
BTB British Telecom Box
BW Brick Wall
B/W Barbed Wire Fence
Cam Camera
CAT Catenary Level
C/B Close Boarded Fence
CC Control Cabinet
CCTV Close Circuit TV
CH Chainage
ChL Channel Level
CI Cast Iron
C/I Corrugated Iron Fence
CL Cover Level
C/L Chain Link Fence
CO Concrete
CP Catch Pit
CpL Coping Level
CTV Cable TV
CUL Culvert
CW Concrete Wall
DI Ductile Iron
dil Dilapidated
dis Disused
D/S Downstream
DSW Dry Stone Wall
EB Electricity Box
EC Electricity Cover
ED Empty Duct
E/F Electric Fence
EFP Electricity Feeder Pillar
EOT End of Trace
EP Electricity Pole
ER Earth Rod
FC Fuel Cover
FFL Finished Floor Level
FH Fire Hydrant
FO Fibre Optic Cover
FS Flag Staff
G Gully
GPRI Ground Penetrating
Radar Inconclusive
GrL Ground Light
GV Gas Valve
H/R Hand Rail
HV High Voltage
IC Inspection Cover
IL Invert Level
I/R Iron Rail Fence
KO Kerb Outlet
LB Letter Box
LC Lighting Column
LH Lamp Hole
LOR Loss Of Reflection
LOS Loss Of Signal
MB Mooring Bollard
M/C Multiple Cables
MH Manhole Cover
Mkr Marker Post
MP Mile Post/Stone
NFI No Further Information
NM Node Marker
NP Name Plate
NPV No Pipes Visible
OSA Off Survey Area
P Post
PBM Permanent Bench Mark
PE Polyethylene
PGM Permanent Ground
Marker
PL Plastic
P/L Palisade Fence
PM Parking Meter
P/R Post and Rail Fence
PS Poor Signal
PU Pump
PVC Polyvinylchloride
P/W Post and Wire Fence
PWR Power
PZ Piezometer
R Radio
RE Rodding Eye
Ri Riser
RL Roof Level
RP Reflector Post
RS Road Sign
RWP Rain Water Pipe
R/W Retaining Wall
S Stump
SA Survey Abandoned
S/A Soakaway
S/B Safety Barrier
SC Speed Camera
S/F Safety Fence
SI Spun Iron
SL Soffit Level
S/L Street Lighting (Electric)
SP Sign Post
Spr Spring
S/R Steel Railings
SS Sonde Stops
ST Stop Tap
STS Structural Support
Stn Survey Station
SV Sluice Valve
SVP Soil Vent Pipe
SW Stone Wall
Tac Tactile Paving
TBM Temporary Bench Mark
TC Telecom Cover
TCB Telephone Call Box
TCP Telephone Call Post
T/F Temporary Fence
TFR Taken From Records
TH Trial Hole / Pit
ThL Threshold Level
Tk Tank
TOW Top Of Wall
TP Telegraph Pole
TS Traffic Signals
TSC Traffic Signals Cover
U/S Upstream
UTGA Unable to Gain Access
UTL Unable to Locate
UTR Unable to Raise
UTS Unable to Survey
UTT Unable to Trace
VC Vitrified Clay
VDP Vehicle Detector Pad
VP Vent Pipe
VR Vapour Recovery
VTP Vertical Pipe
W Water Cover
WL Water Level
WM Water Meter
W/M Wire Mesh Fence
WO Wash Out
WS Window Sample
WV Wheel Valve
JN BENTLEY LTD
KEIGHLEY ROAD
SKIPTON
BD23 2QR
ROLLS ROYCE
TOPOGRAPHICAL AND GPR
SURVEY
LB / DS VK GJ
1:200 @ A2 07 / 2019
1803_P
11 of 17 A2
ORDNANCE SURVEY
RELATED TO THE OS
ACTIVE STATIONS BY
GPS OBSERVATIONS
ORDNANCE SURVEY
RELATED TO THE OS ACTIVE STATIONS BY
GPS OBSERVATIONS
Unknown
Unknown Route
Located By GPR
G
P
R
S
c
a
n
9
5
1
4
3
BO
43.48
42.64
42.71
42.84
42.994
2
.
5
7
4
2
.
7
4
4
2
.
8
9
4
2
.
8
9
4
3
.
1
1
4
3
.
3
4
4
3
.
4
9
4
3
.
6
2
4
3
.
6
7
4
3
.
3
3
4
3
.
4
9
4
3
.
4
4
4
3
.
5
2
4
3
.
1
6
4
3
.
0
7
4
2
.
8
5
4
3
.
6
9
4
3
.
7
5
4
3
.
7
3
4
3
.
6
6
4
3
.
5
6
4
3
.
5
4
4
3
.
5
4
4
3
.5
3
4
3
.6
3
4
2
.
7
4
4
2
.
7
0
4
2
.
5
2
4
2
.
3
9
C
/
L
H
t
=
2
.
4
0
m
ABBREVIATIONS
NOTES
REV. DETAILS BY
GRID DATUM
SURVEYED BY: DRAWN BY:
SCALE:
APPROVED BY:
SURVEY DATE:
REV:
DATE
CLIENT:
PROJECT TITLE:
DRAWING TITLE:
DRAWING NUMBER:
SHEET NUMBER:
Structure Overhead
Structure Underground
Building Canopy
Building Overhead
Wall
Structure
Building
Above Ground Pipe
Drainage Channel
Banking
Fence
Surface Edge
Road Kerb Channel
Road Edge
Vegetation Extents
Overhead Pipe
Overhead Electricity
Overhead Telecom
TOPOGRAPHICAL AND UTILITY LEGEND
Scar
Railway Track
Contour Line
220
LEEDS
E-Mail: [email protected] Web site: www.40seven.com
LONDON
01732 7406960113 201 9700
AC Asbestos Cement
ACU Air Conditioning Unit
AD Assumed Direction
AR Assumed Route
AV Air Valve
BB Belisha Beacon
BD Back Drop
BdL Bed Level
BH Borehole
Bk Brick
BL Basement Light
BO Bollard
BOC Bottom of Chamber
BR Brick
BS Bus Stop
BT British Telecom Cover
BTB British Telecom Box
BW Brick Wall
B/W Barbed Wire Fence
Cam Camera
CAT Catenary Level
C/B Close Boarded Fence
CC Control Cabinet
CCTV Close Circuit TV
CH Chainage
ChL Channel Level
CI Cast Iron
C/I Corrugated Iron Fence
CL Cover Level
C/L Chain Link Fence
CO Concrete
CP Catch Pit
CpL Coping Level
CTV Cable TV
CUL Culvert
CW Concrete Wall
DI Ductile Iron
dil Dilapidated
dis Disused
D/S Downstream
DSW Dry Stone Wall
EB Electricity Box
EC Electricity Cover
ED Empty Duct
E/F Electric Fence
EFP Electricity Feeder Pillar
EOT End of Trace
EP Electricity Pole
ER Earth Rod
FC Fuel Cover
FFL Finished Floor Level
FH Fire Hydrant
FO Fibre Optic Cover
FS Flag Staff
G Gully
GPRI Ground Penetrating
Radar Inconclusive
GrL Ground Light
GV Gas Valve
H/R Hand Rail
HV High Voltage
IC Inspection Cover
IL Invert Level
I/R Iron Rail Fence
KO Kerb Outlet
LB Letter Box
LC Lighting Column
LH Lamp Hole
LOR Loss Of Reflection
LOS Loss Of Signal
MB Mooring Bollard
M/C Multiple Cables
MH Manhole Cover
Mkr Marker Post
MP Mile Post/Stone
NFI No Further Information
NM Node Marker
NP Name Plate
NPV No Pipes Visible
OSA Off Survey Area
P Post
PBM Permanent Bench Mark
PE Polyethylene
PGM Permanent Ground
Marker
PL Plastic
P/L Palisade Fence
PM Parking Meter
P/R Post and Rail Fence
PS Poor Signal
PU Pump
PVC Polyvinylchloride
P/W Post and Wire Fence
PWR Power
PZ Piezometer
R Radio
RE Rodding Eye
Ri Riser
RL Roof Level
RP Reflector Post
RS Road Sign
RWP Rain Water Pipe
R/W Retaining Wall
S Stump
SA Survey Abandoned
S/A Soakaway
S/B Safety Barrier
SC Speed Camera
S/F Safety Fence
SI Spun Iron
SL Soffit Level
S/L Street Lighting (Electric)
SP Sign Post
Spr Spring
S/R Steel Railings
SS Sonde Stops
ST Stop Tap
STS Structural Support
Stn Survey Station
SV Sluice Valve
SVP Soil Vent Pipe
SW Stone Wall
Tac Tactile Paving
TBM Temporary Bench Mark
TC Telecom Cover
TCB Telephone Call Box
TCP Telephone Call Post
T/F Temporary Fence
TFR Taken From Records
TH Trial Hole / Pit
ThL Threshold Level
Tk Tank
TOW Top Of Wall
TP Telegraph Pole
TS Traffic Signals
TSC Traffic Signals Cover
U/S Upstream
UTGA Unable to Gain Access
UTL Unable to Locate
UTR Unable to Raise
UTS Unable to Survey
UTT Unable to Trace
VC Vitrified Clay
VDP Vehicle Detector Pad
VP Vent Pipe
VR Vapour Recovery
VTP Vertical Pipe
W Water Cover
WL Water Level
WM Water Meter
W/M Wire Mesh Fence
WO Wash Out
WS Window Sample
WV Wheel Valve
JN BENTLEY LTD
KEIGHLEY ROAD
SKIPTON
BD23 2QR
ROLLS ROYCE
TOPOGRAPHICAL AND GPR
SURVEY
LB / DS VK GJ
1:200 @ A2 07 / 2019
1803_P
12 of 17 A2
ORDNANCE SURVEY
RELATED TO THE OS
ACTIVE STATIONS BY
GPS OBSERVATIONS
ORDNANCE SURVEY
RELATED TO THE OS ACTIVE STATIONS BY
GPS OBSERVATIONS
Unknown
Unknown Route
Located By GPR
G
P
R
S
c
a
n
4
2
9
42.21
42.24
42.25
42.31
42.34
42.37
42.37
42.64
4
2
.
2
4
4
2
.
3
2
4
2
.
3
6
4
2
.
4
9
4
2
.
4
8
4
2
.
5
7
4
2
.
7
4
4
3
.5
3
4
3
.6
3
4
3
.
6
2
4
3
.
6
5
4
3
.
6
6
4
3
.
6
4
4
3
.
5
5
4
2
.
3
9
4
2
.
2
8
4
2
.
2
3
4
2
.
0
7
4
2
.
1
0
4
2
.
1
2
4
2
.
1
0
4
2
.
1
3
ABBREVIATIONS
NOTES
REV. DETAILS BY
GRID DATUM
SURVEYED BY: DRAWN BY:
SCALE:
APPROVED BY:
SURVEY DATE:
REV:
DATE
CLIENT:
PROJECT TITLE:
DRAWING TITLE:
DRAWING NUMBER:
SHEET NUMBER:
Structure Overhead
Structure Underground
Building Canopy
Building Overhead
Wall
Structure
Building
Above Ground Pipe
Drainage Channel
Banking
Fence
Surface Edge
Road Kerb Channel
Road Edge
Vegetation Extents
Overhead Pipe
Overhead Electricity
Overhead Telecom
TOPOGRAPHICAL AND UTILITY LEGEND
Scar
Railway Track
Contour Line
220
LEEDS
E-Mail: [email protected] Web site: www.40seven.com
LONDON
01732 7406960113 201 9700
AC Asbestos Cement
ACU Air Conditioning Unit
AD Assumed Direction
AR Assumed Route
AV Air Valve
BB Belisha Beacon
BD Back Drop
BdL Bed Level
BH Borehole
Bk Brick
BL Basement Light
BO Bollard
BOC Bottom of Chamber
BR Brick
BS Bus Stop
BT British Telecom Cover
BTB British Telecom Box
BW Brick Wall
B/W Barbed Wire Fence
Cam Camera
CAT Catenary Level
C/B Close Boarded Fence
CC Control Cabinet
CCTV Close Circuit TV
CH Chainage
ChL Channel Level
CI Cast Iron
C/I Corrugated Iron Fence
CL Cover Level
C/L Chain Link Fence
CO Concrete
CP Catch Pit
CpL Coping Level
CTV Cable TV
CUL Culvert
CW Concrete Wall
DI Ductile Iron
dil Dilapidated
dis Disused
D/S Downstream
DSW Dry Stone Wall
EB Electricity Box
EC Electricity Cover
ED Empty Duct
E/F Electric Fence
EFP Electricity Feeder Pillar
EOT End of Trace
EP Electricity Pole
ER Earth Rod
FC Fuel Cover
FFL Finished Floor Level
FH Fire Hydrant
FO Fibre Optic Cover
FS Flag Staff
G Gully
GPRI Ground Penetrating
Radar Inconclusive
GrL Ground Light
GV Gas Valve
H/R Hand Rail
HV High Voltage
IC Inspection Cover
IL Invert Level
I/R Iron Rail Fence
KO Kerb Outlet
LB Letter Box
LC Lighting Column
LH Lamp Hole
LOR Loss Of Reflection
LOS Loss Of Signal
MB Mooring Bollard
M/C Multiple Cables
MH Manhole Cover
Mkr Marker Post
MP Mile Post/Stone
NFI No Further Information
NM Node Marker
NP Name Plate
NPV No Pipes Visible
OSA Off Survey Area
P Post
PBM Permanent Bench Mark
PE Polyethylene
PGM Permanent Ground
Marker
PL Plastic
P/L Palisade Fence
PM Parking Meter
P/R Post and Rail Fence
PS Poor Signal
PU Pump
PVC Polyvinylchloride
P/W Post and Wire Fence
PWR Power
PZ Piezometer
R Radio
RE Rodding Eye
Ri Riser
RL Roof Level
RP Reflector Post
RS Road Sign
RWP Rain Water Pipe
R/W Retaining Wall
S Stump
SA Survey Abandoned
S/A Soakaway
S/B Safety Barrier
SC Speed Camera
S/F Safety Fence
SI Spun Iron
SL Soffit Level
S/L Street Lighting (Electric)
SP Sign Post
Spr Spring
S/R Steel Railings
SS Sonde Stops
ST Stop Tap
STS Structural Support
Stn Survey Station
SV Sluice Valve
SVP Soil Vent Pipe
SW Stone Wall
Tac Tactile Paving
TBM Temporary Bench Mark
TC Telecom Cover
TCB Telephone Call Box
TCP Telephone Call Post
T/F Temporary Fence
TFR Taken From Records
TH Trial Hole / Pit
ThL Threshold Level
Tk Tank
TOW Top Of Wall
TP Telegraph Pole
TS Traffic Signals
TSC Traffic Signals Cover
U/S Upstream
UTGA Unable to Gain Access
UTL Unable to Locate
UTR Unable to Raise
UTS Unable to Survey
UTT Unable to Trace
VC Vitrified Clay
VDP Vehicle Detector Pad
VP Vent Pipe
VR Vapour Recovery
VTP Vertical Pipe
W Water Cover
WL Water Level
WM Water Meter
W/M Wire Mesh Fence
WO Wash Out
WS Window Sample
WV Wheel Valve
JN BENTLEY LTD
KEIGHLEY ROAD
SKIPTON
BD23 2QR
ROLLS ROYCE
TOPOGRAPHICAL AND GPR
SURVEY
LB / DS VK GJ
1:200 @ A2 07 / 2019
1803_P
13 of 17 A2
ORDNANCE SURVEY
RELATED TO THE OS
ACTIVE STATIONS BY
GPS OBSERVATIONS
ORDNANCE SURVEY
RELATED TO THE OS ACTIVE STATIONS BY
GPS OBSERVATIONS
Unknown
Unknown Route
Located By GPR
42.22
42.07
42.10
42.18
42.18
42.11
42.15
42.21
4
2
.
4
1
4
2
.
2
7
4
2
.
1
8
4
2
.
3
8
4
2
.
2
6
4
2
.
1
8
4
2
.
2
4
4
3
.
5
5
4
3
.
5
7
4
3
.
5
6
4
3
.
4
9
4
3
.
3
6
4
3
.
4
9
4
3
.
5
5
4
2
.
1
3
4
2
.
0
4
4
2
.
0
6
4
2
.
0
0
4
2
.
0
3
4
2
.
0
5
4
2
.
0
7
4
2
.
1
7
ABBREVIATIONS
NOTES
REV. DETAILS BY
GRID DATUM
SURVEYED BY: DRAWN BY:
SCALE:
APPROVED BY:
SURVEY DATE:
REV:
DATE
CLIENT:
PROJECT TITLE:
DRAWING TITLE:
DRAWING NUMBER:
SHEET NUMBER:
Structure Overhead
Structure Underground
Building Canopy
Building Overhead
Wall
Structure
Building
Above Ground Pipe
Drainage Channel
Banking
Fence
Surface Edge
Road Kerb Channel
Road Edge
Vegetation Extents
Overhead Pipe
Overhead Electricity
Overhead Telecom
TOPOGRAPHICAL AND UTILITY LEGEND
Scar
Railway Track
Contour Line
220
LEEDS
E-Mail: [email protected] Web site: www.40seven.com
LONDON
01732 7406960113 201 9700
AC Asbestos Cement
ACU Air Conditioning Unit
AD Assumed Direction
AR Assumed Route
AV Air Valve
BB Belisha Beacon
BD Back Drop
BdL Bed Level
BH Borehole
Bk Brick
BL Basement Light
BO Bollard
BOC Bottom of Chamber
BR Brick
BS Bus Stop
BT British Telecom Cover
BTB British Telecom Box
BW Brick Wall
B/W Barbed Wire Fence
Cam Camera
CAT Catenary Level
C/B Close Boarded Fence
CC Control Cabinet
CCTV Close Circuit TV
CH Chainage
ChL Channel Level
CI Cast Iron
C/I Corrugated Iron Fence
CL Cover Level
C/L Chain Link Fence
CO Concrete
CP Catch Pit
CpL Coping Level
CTV Cable TV
CUL Culvert
CW Concrete Wall
DI Ductile Iron
dil Dilapidated
dis Disused
D/S Downstream
DSW Dry Stone Wall
EB Electricity Box
EC Electricity Cover
ED Empty Duct
E/F Electric Fence
EFP Electricity Feeder Pillar
EOT End of Trace
EP Electricity Pole
ER Earth Rod
FC Fuel Cover
FFL Finished Floor Level
FH Fire Hydrant
FO Fibre Optic Cover
FS Flag Staff
G Gully
GPRI Ground Penetrating
Radar Inconclusive
GrL Ground Light
GV Gas Valve
H/R Hand Rail
HV High Voltage
IC Inspection Cover
IL Invert Level
I/R Iron Rail Fence
KO Kerb Outlet
LB Letter Box
LC Lighting Column
LH Lamp Hole
LOR Loss Of Reflection
LOS Loss Of Signal
MB Mooring Bollard
M/C Multiple Cables
MH Manhole Cover
Mkr Marker Post
MP Mile Post/Stone
NFI No Further Information
NM Node Marker
NP Name Plate
NPV No Pipes Visible
OSA Off Survey Area
P Post
PBM Permanent Bench Mark
PE Polyethylene
PGM Permanent Ground
Marker
PL Plastic
P/L Palisade Fence
PM Parking Meter
P/R Post and Rail Fence
PS Poor Signal
PU Pump
PVC Polyvinylchloride
P/W Post and Wire Fence
PWR Power
PZ Piezometer
R Radio
RE Rodding Eye
Ri Riser
RL Roof Level
RP Reflector Post
RS Road Sign
RWP Rain Water Pipe
R/W Retaining Wall
S Stump
SA Survey Abandoned
S/A Soakaway
S/B Safety Barrier
SC Speed Camera
S/F Safety Fence
SI Spun Iron
SL Soffit Level
S/L Street Lighting (Electric)
SP Sign Post
Spr Spring
S/R Steel Railings
SS Sonde Stops
ST Stop Tap
STS Structural Support
Stn Survey Station
SV Sluice Valve
SVP Soil Vent Pipe
SW Stone Wall
Tac Tactile Paving
TBM Temporary Bench Mark
TC Telecom Cover
TCB Telephone Call Box
TCP Telephone Call Post
T/F Temporary Fence
TFR Taken From Records
TH Trial Hole / Pit
ThL Threshold Level
Tk Tank
TOW Top Of Wall
TP Telegraph Pole
TS Traffic Signals
TSC Traffic Signals Cover
U/S Upstream
UTGA Unable to Gain Access
UTL Unable to Locate
UTR Unable to Raise
UTS Unable to Survey
UTT Unable to Trace
VC Vitrified Clay
VDP Vehicle Detector Pad
VP Vent Pipe
VR Vapour Recovery
VTP Vertical Pipe
W Water Cover
WL Water Level
WM Water Meter
W/M Wire Mesh Fence
WO Wash Out
WS Window Sample
WV Wheel Valve
JN BENTLEY LTD
KEIGHLEY ROAD
SKIPTON
BD23 2QR
ROLLS ROYCE
TOPOGRAPHICAL AND GPR
SURVEY
LB / DS VK GJ
1:200 @ A2 07 / 2019
1803_P
14 of 17 A2
ORDNANCE SURVEY
RELATED TO THE OS
ACTIVE STATIONS BY
GPS OBSERVATIONS
ORDNANCE SURVEY
RELATED TO THE OS ACTIVE STATIONS BY
GPS OBSERVATIONS
Unknown
Unknown Route
Located By GPR
G
P
R
S
c
a
n
9
3
4
4
3
4
3
4
3
4
3
.0
3
4
3
.0
5
4
3
.
8
0
BO
4
3
.0
9
43.70
43.62
43.20
43.76
43.66
43.68
42.79
42.33
42.48
42.27
42.24
42.20
42.22
Slabs
42.62
42.5
8
4
3
.
8
0
4
3
.
7
5
4
3
.
0
5
4
3
.
0
1
4
2
.
9
9
4
3
.
0
0
4
2
.
4
8
4
3
.
4
1
4
3
.
6
0
4
2
.
8
6
4
2
.
8
9
4
2
.8
3
4
2
.6
3
R
a
i
l
w
a
y
S
l
e
e
p
e
r
s
0
.
3
0
m
4
3
.
4
8
4
3
.
7
7
4
3
.
1
5
4
3
.6
9
4
3
.8
9
4
3
.
6
5
4
3
.7
4
4
3
.
7
4
4
3
.
1
0
42.50
42.45
42.41
4
2
.
4
4
4
2
.
4
3
4
2
.
4
1
Concrete
Ht=
0.1
0m
42.9
7
C
o
n
c
r
e
t
e
H
t
=
0
.
1
0
m
4
2
.
5
8
C
/
L
H
t
=
2
.
4
0
m
C
/
L
H
t
=
2
.
4
0
m
C
/
L
H
t
=
2
.
4
0
m
C/L
Ht=
2.4
0m
Cricket Changing Rooms
4
3
.
5
5
4
3
.5
4
43.49
43.46
43.45
4
3
.4
0
4
3
.
8
1
4
3
.
9
5
C
/
B
H
t
=
1
.
2
0
m
4
2
.
1
7
4
2
.
1
3
4
2
.
1
9
4
2
.
1
8
4
2
.
2
6
4
2
.
3
4
4
2
.
3
6
4
3
.
0
2
4
3
.
8
3
4
3
.
7
8
4
3
.
9
1
43.9
4
4
3
.
6
9
4
3
.
8
1
4
3
.
7
7
4
3
.
7
1
4
3
.
5
5
ABBREVIATIONS
NOTES
REV. DETAILS BY
GRID DATUM
SURVEYED BY: DRAWN BY:
SCALE:
APPROVED BY:
SURVEY DATE:
REV:
DATE
CLIENT:
PROJECT TITLE:
DRAWING TITLE:
DRAWING NUMBER:
SHEET NUMBER:
Structure Overhead
Structure Underground
Building Canopy
Building Overhead
Wall
Structure
Building
Above Ground Pipe
Drainage Channel
Banking
Fence
Surface Edge
Road Kerb Channel
Road Edge
Vegetation Extents
Overhead Pipe
Overhead Electricity
Overhead Telecom
TOPOGRAPHICAL AND UTILITY LEGEND
Scar
Railway Track
Contour Line
220
LEEDS
E-Mail: [email protected] Web site: www.40seven.com
LONDON
01732 7406960113 201 9700
AC Asbestos Cement
ACU Air Conditioning Unit
AD Assumed Direction
AR Assumed Route
AV Air Valve
BB Belisha Beacon
BD Back Drop
BdL Bed Level
BH Borehole
Bk Brick
BL Basement Light
BO Bollard
BOC Bottom of Chamber
BR Brick
BS Bus Stop
BT British Telecom Cover
BTB British Telecom Box
BW Brick Wall
B/W Barbed Wire Fence
Cam Camera
CAT Catenary Level
C/B Close Boarded Fence
CC Control Cabinet
CCTV Close Circuit TV
CH Chainage
ChL Channel Level
CI Cast Iron
C/I Corrugated Iron Fence
CL Cover Level
C/L Chain Link Fence
CO Concrete
CP Catch Pit
CpL Coping Level
CTV Cable TV
CUL Culvert
CW Concrete Wall
DI Ductile Iron
dil Dilapidated
dis Disused
D/S Downstream
DSW Dry Stone Wall
EB Electricity Box
EC Electricity Cover
ED Empty Duct
E/F Electric Fence
EFP Electricity Feeder Pillar
EOT End of Trace
EP Electricity Pole
ER Earth Rod
FC Fuel Cover
FFL Finished Floor Level
FH Fire Hydrant
FO Fibre Optic Cover
FS Flag Staff
G Gully
GPRI Ground Penetrating
Radar Inconclusive
GrL Ground Light
GV Gas Valve
H/R Hand Rail
HV High Voltage
IC Inspection Cover
IL Invert Level
I/R Iron Rail Fence
KO Kerb Outlet
LB Letter Box
LC Lighting Column
LH Lamp Hole
LOR Loss Of Reflection
LOS Loss Of Signal
MB Mooring Bollard
M/C Multiple Cables
MH Manhole Cover
Mkr Marker Post
MP Mile Post/Stone
NFI No Further Information
NM Node Marker
NP Name Plate
NPV No Pipes Visible
OSA Off Survey Area
P Post
PBM Permanent Bench Mark
PE Polyethylene
PGM Permanent Ground
Marker
PL Plastic
P/L Palisade Fence
PM Parking Meter
P/R Post and Rail Fence
PS Poor Signal
PU Pump
PVC Polyvinylchloride
P/W Post and Wire Fence
PWR Power
PZ Piezometer
R Radio
RE Rodding Eye
Ri Riser
RL Roof Level
RP Reflector Post
RS Road Sign
RWP Rain Water Pipe
R/W Retaining Wall
S Stump
SA Survey Abandoned
S/A Soakaway
S/B Safety Barrier
SC Speed Camera
S/F Safety Fence
SI Spun Iron
SL Soffit Level
S/L Street Lighting (Electric)
SP Sign Post
Spr Spring
S/R Steel Railings
SS Sonde Stops
ST Stop Tap
STS Structural Support
Stn Survey Station
SV Sluice Valve
SVP Soil Vent Pipe
SW Stone Wall
Tac Tactile Paving
TBM Temporary Bench Mark
TC Telecom Cover
TCB Telephone Call Box
TCP Telephone Call Post
T/F Temporary Fence
TFR Taken From Records
TH Trial Hole / Pit
ThL Threshold Level
Tk Tank
TOW Top Of Wall
TP Telegraph Pole
TS Traffic Signals
TSC Traffic Signals Cover
U/S Upstream
UTGA Unable to Gain Access
UTL Unable to Locate
UTR Unable to Raise
UTS Unable to Survey
UTT Unable to Trace
VC Vitrified Clay
VDP Vehicle Detector Pad
VP Vent Pipe
VR Vapour Recovery
VTP Vertical Pipe
W Water Cover
WL Water Level
WM Water Meter
W/M Wire Mesh Fence
WO Wash Out
WS Window Sample
WV Wheel Valve
JN BENTLEY LTD
KEIGHLEY ROAD
SKIPTON
BD23 2QR
ROLLS ROYCE
TOPOGRAPHICAL AND GPR
SURVEY
LB / DS VK GJ
1:200 @ A2 07 / 2019
1803_P
15 of 17 A2
ORDNANCE SURVEY
RELATED TO THE OS
ACTIVE STATIONS BY
GPS OBSERVATIONS
ORDNANCE SURVEY
RELATED TO THE OS ACTIVE STATIONS BY
GPS OBSERVATIONS
Unknown
Unknown Route
Located By GPR
Bench
Bench
Bench
Bench
Bench
42.69
42.75
42.68
42.65
42.66
42.67
42.66
42.62
42.66
42.8
0
42.8
2
42.91
42.86
42.8
8
42.96
42.9
6
42.9
6
42.9
8
43.0
4
43.0
0
43.0
1
42.8
5
42.62
42.5
8
4
2
.
9
9
42.9
8
42.97
42.9
8
42.94
42.8
3
42.83
42.8
5
42.8
1
4
2
.8
2
42.8
4
42.7
7
42.7
9
Concrete
Ht=
0.1
0m
Concrete
Ht=
0.2
0m
42.9
7
42.6
2
42.7
9
42.9
5
42.8
9
42.9
2
42.9
3
42.7
9
42.6
8
C/L
Ht=
2.4
0m
C/L
Ht=
2.4
0m
42.6
9
42.7
2
42.6
9
42.7
8
42.8
4
42.8
4
42.8
3
42.62
H
eras F
ence
ABBREVIATIONS
NOTES
REV. DETAILS BY
GRID DATUM
SURVEYED BY: DRAWN BY:
SCALE:
APPROVED BY:
SURVEY DATE:
REV:
DATE
CLIENT:
PROJECT TITLE:
DRAWING TITLE:
DRAWING NUMBER:
SHEET NUMBER:
Structure Overhead
Structure Underground
Building Canopy
Building Overhead
Wall
Structure
Building
Above Ground Pipe
Drainage Channel
Banking
Fence
Surface Edge
Road Kerb Channel
Road Edge
Vegetation Extents
Overhead Pipe
Overhead Electricity
Overhead Telecom
TOPOGRAPHICAL AND UTILITY LEGEND
Scar
Railway Track
Contour Line
220
LEEDS
E-Mail: [email protected] Web site: www.40seven.com
LONDON
01732 7406960113 201 9700
AC Asbestos Cement
ACU Air Conditioning Unit
AD Assumed Direction
AR Assumed Route
AV Air Valve
BB Belisha Beacon
BD Back Drop
BdL Bed Level
BH Borehole
Bk Brick
BL Basement Light
BO Bollard
BOC Bottom of Chamber
BR Brick
BS Bus Stop
BT British Telecom Cover
BTB British Telecom Box
BW Brick Wall
B/W Barbed Wire Fence
Cam Camera
CAT Catenary Level
C/B Close Boarded Fence
CC Control Cabinet
CCTV Close Circuit TV
CH Chainage
ChL Channel Level
CI Cast Iron
C/I Corrugated Iron Fence
CL Cover Level
C/L Chain Link Fence
CO Concrete
CP Catch Pit
CpL Coping Level
CTV Cable TV
CUL Culvert
CW Concrete Wall
DI Ductile Iron
dil Dilapidated
dis Disused
D/S Downstream
DSW Dry Stone Wall
EB Electricity Box
EC Electricity Cover
ED Empty Duct
E/F Electric Fence
EFP Electricity Feeder Pillar
EOT End of Trace
EP Electricity Pole
ER Earth Rod
FC Fuel Cover
FFL Finished Floor Level
FH Fire Hydrant
FO Fibre Optic Cover
FS Flag Staff
G Gully
GPRI Ground Penetrating
Radar Inconclusive
GrL Ground Light
GV Gas Valve
H/R Hand Rail
HV High Voltage
IC Inspection Cover
IL Invert Level
I/R Iron Rail Fence
KO Kerb Outlet
LB Letter Box
LC Lighting Column
LH Lamp Hole
LOR Loss Of Reflection
LOS Loss Of Signal
MB Mooring Bollard
M/C Multiple Cables
MH Manhole Cover
Mkr Marker Post
MP Mile Post/Stone
NFI No Further Information
NM Node Marker
NP Name Plate
NPV No Pipes Visible
OSA Off Survey Area
P Post
PBM Permanent Bench Mark
PE Polyethylene
PGM Permanent Ground
Marker
PL Plastic
P/L Palisade Fence
PM Parking Meter
P/R Post and Rail Fence
PS Poor Signal
PU Pump
PVC Polyvinylchloride
P/W Post and Wire Fence
PWR Power
PZ Piezometer
R Radio
RE Rodding Eye
Ri Riser
RL Roof Level
RP Reflector Post
RS Road Sign
RWP Rain Water Pipe
R/W Retaining Wall
S Stump
SA Survey Abandoned
S/A Soakaway
S/B Safety Barrier
SC Speed Camera
S/F Safety Fence
SI Spun Iron
SL Soffit Level
S/L Street Lighting (Electric)
SP Sign Post
Spr Spring
S/R Steel Railings
SS Sonde Stops
ST Stop Tap
STS Structural Support
Stn Survey Station
SV Sluice Valve
SVP Soil Vent Pipe
SW Stone Wall
Tac Tactile Paving
TBM Temporary Bench Mark
TC Telecom Cover
TCB Telephone Call Box
TCP Telephone Call Post
T/F Temporary Fence
TFR Taken From Records
TH Trial Hole / Pit
ThL Threshold Level
Tk Tank
TOW Top Of Wall
TP Telegraph Pole
TS Traffic Signals
TSC Traffic Signals Cover
U/S Upstream
UTGA Unable to Gain Access
UTL Unable to Locate
UTR Unable to Raise
UTS Unable to Survey
UTT Unable to Trace
VC Vitrified Clay
VDP Vehicle Detector Pad
VP Vent Pipe
VR Vapour Recovery
VTP Vertical Pipe
W Water Cover
WL Water Level
WM Water Meter
W/M Wire Mesh Fence
WO Wash Out
WS Window Sample
WV Wheel Valve
JN BENTLEY LTD
KEIGHLEY ROAD
SKIPTON
BD23 2QR
ROLLS ROYCE
TOPOGRAPHICAL AND GPR
SURVEY
LB / DS VK GJ
1:200 @ A2 07 / 2019
1803_P
16 of 17 A2
ORDNANCE SURVEY
RELATED TO THE OS
ACTIVE STATIONS BY
GPS OBSERVATIONS
ORDNANCE SURVEY
RELATED TO THE OS ACTIVE STATIONS BY
GPS OBSERVATIONS
Unknown
Unknown Route
Located By GPR
GP
R S
can 2
19
B
e
n
c
h
Bench
Bench
Grass
Gravel
42.66
42.62
42.66
P
42.5
1
42.5
7
42.59
4
2
.
8
0
42.7
8
42.7
4
42.8
0
42.8
2
4
2
.
8
0
4
2
.
7
7
4
2
.
7
8
4
2
.
8
0
42.8
5
42.8
1
4
2
.8
2
42.8
4
42.7
7
42.7
9
4
2
.
7
5
42.6
8
42.5
8
42.4
9
42.5
5
42.5
3
42.4
2
42.5
2
4
2
.
7
4
4
2
.
6
5
4
2
.
6
4
P
/
R
H
t
=
1
.
0
0
m
42.69
42.5
8
42.6
9
42.7
2
H
eras F
ence
4
2
.5
9
4
2
.6
4
42.63
42.58
42.56
42.61
42.57
42.57
42.56
42.56
42.62
42.69
4
2
.6
8
4
2
.6
2
42.55
42.53
42.51
42.54
ABBREVIATIONS
NOTES
REV. DETAILS BY
GRID DATUM
SURVEYED BY: DRAWN BY:
SCALE:
APPROVED BY:
SURVEY DATE:
REV:
DATE
CLIENT:
PROJECT TITLE:
DRAWING TITLE:
DRAWING NUMBER:
SHEET NUMBER:
Structure Overhead
Structure Underground
Building Canopy
Building Overhead
Wall
Structure
Building
Above Ground Pipe
Drainage Channel
Banking
Fence
Surface Edge
Road Kerb Channel
Road Edge
Vegetation Extents
Overhead Pipe
Overhead Electricity
Overhead Telecom
TOPOGRAPHICAL AND UTILITY LEGEND
Scar
Railway Track
Contour Line
220
LEEDS
E-Mail: [email protected] Web site: www.40seven.com
LONDON
01732 7406960113 201 9700
AC Asbestos Cement
ACU Air Conditioning Unit
AD Assumed Direction
AR Assumed Route
AV Air Valve
BB Belisha Beacon
BD Back Drop
BdL Bed Level
BH Borehole
Bk Brick
BL Basement Light
BO Bollard
BOC Bottom of Chamber
BR Brick
BS Bus Stop
BT British Telecom Cover
BTB British Telecom Box
BW Brick Wall
B/W Barbed Wire Fence
Cam Camera
CAT Catenary Level
C/B Close Boarded Fence
CC Control Cabinet
CCTV Close Circuit TV
CH Chainage
ChL Channel Level
CI Cast Iron
C/I Corrugated Iron Fence
CL Cover Level
C/L Chain Link Fence
CO Concrete
CP Catch Pit
CpL Coping Level
CTV Cable TV
CUL Culvert
CW Concrete Wall
DI Ductile Iron
dil Dilapidated
dis Disused
D/S Downstream
DSW Dry Stone Wall
EB Electricity Box
EC Electricity Cover
ED Empty Duct
E/F Electric Fence
EFP Electricity Feeder Pillar
EOT End of Trace
EP Electricity Pole
ER Earth Rod
FC Fuel Cover
FFL Finished Floor Level
FH Fire Hydrant
FO Fibre Optic Cover
FS Flag Staff
G Gully
GPRI Ground Penetrating
Radar Inconclusive
GrL Ground Light
GV Gas Valve
H/R Hand Rail
HV High Voltage
IC Inspection Cover
IL Invert Level
I/R Iron Rail Fence
KO Kerb Outlet
LB Letter Box
LC Lighting Column
LH Lamp Hole
LOR Loss Of Reflection
LOS Loss Of Signal
MB Mooring Bollard
M/C Multiple Cables
MH Manhole Cover
Mkr Marker Post
MP Mile Post/Stone
NFI No Further Information
NM Node Marker
NP Name Plate
NPV No Pipes Visible
OSA Off Survey Area
P Post
PBM Permanent Bench Mark
PE Polyethylene
PGM Permanent Ground
Marker
PL Plastic
P/L Palisade Fence
PM Parking Meter
P/R Post and Rail Fence
PS Poor Signal
PU Pump
PVC Polyvinylchloride
P/W Post and Wire Fence
PWR Power
PZ Piezometer
R Radio
RE Rodding Eye
Ri Riser
RL Roof Level
RP Reflector Post
RS Road Sign
RWP Rain Water Pipe
R/W Retaining Wall
S Stump
SA Survey Abandoned
S/A Soakaway
S/B Safety Barrier
SC Speed Camera
S/F Safety Fence
SI Spun Iron
SL Soffit Level
S/L Street Lighting (Electric)
SP Sign Post
Spr Spring
S/R Steel Railings
SS Sonde Stops
ST Stop Tap
STS Structural Support
Stn Survey Station
SV Sluice Valve
SVP Soil Vent Pipe
SW Stone Wall
Tac Tactile Paving
TBM Temporary Bench Mark
TC Telecom Cover
TCB Telephone Call Box
TCP Telephone Call Post
T/F Temporary Fence
TFR Taken From Records
TH Trial Hole / Pit
ThL Threshold Level
Tk Tank
TOW Top Of Wall
TP Telegraph Pole
TS Traffic Signals
TSC Traffic Signals Cover
U/S Upstream
UTGA Unable to Gain Access
UTL Unable to Locate
UTR Unable to Raise
UTS Unable to Survey
UTT Unable to Trace
VC Vitrified Clay
VDP Vehicle Detector Pad
VP Vent Pipe
VR Vapour Recovery
VTP Vertical Pipe
W Water Cover
WL Water Level
WM Water Meter
W/M Wire Mesh Fence
WO Wash Out
WS Window Sample
WV Wheel Valve
JN BENTLEY LTD
KEIGHLEY ROAD
SKIPTON
BD23 2QR
ROLLS ROYCE
TOPOGRAPHICAL AND GPR
SURVEY
LB / DS VK GJ
1:200 @ A2 07 / 2019
1803_P
17 of 17 A2
ORDNANCE SURVEY
RELATED TO THE OS
ACTIVE STATIONS BY
GPS OBSERVATIONS
ORDNANCE SURVEY
RELATED TO THE OS ACTIVE STATIONS BY
GPS OBSERVATIONS
Unknown
Unknown Route
Located By GPR