4
WESTELL.COM General Informaon Alphanumeric user interface Integrated digital power/AGC meter allows for precise set up without test equipment Oscillaon detecon and suppression control feature to prevent network interference Each band is independently controlled Local alarm contact closure points and interface for remote shutdown Gain Opons 51062: 65 dB of Gain 51065: 65 dB of Gain 51075: 75 dB of Gain 51080: 80 dB of Gain 61080: 80 dB of Gain Typical Applicaons Parking Garages Warehouses Basements Shielded Structures Metal Buildings Office Complexes Campus Environments Hospitals and Convenon Centers General Descripon The model 510 and 610 series of in-building amplifiers provide amplificaon of both uplink and downlink wireless signals in facilies located within reasonable proximity of cell sites and where wireless coverage is otherwise non-existent. Model 510 / 610 Series In-Building Amplifier Page 1 of 4 Model Type/Band Combinaons/Gain Values 51062/51065 51075 51080 61080 Single Band C, PS7, PS8, P C, PS7, PS8, P PS8 C, PS8, P Dual Band C/P, PS8/S9 C/P, PS8/S9 - C/P, P/P, P/S9 Gain (dB) 65 75 80 80 *Refers to available band combinaons by model Band Designaon* C Cellular 850 PS7 SMR 700 PS8 SMR 800 P PCS 1900 S9 SMR 900

Model 510 / 610 Series In-Building Amplifiersupport.westell.com/documents/030-200201 rB...030-200201 rB 5/22/14 Page 4 of 4 Model 510 / 610 Series In-Building Amplifier Sample Model

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Model 510 / 610 Series In-Building Amplifiersupport.westell.com/documents/030-200201 rB...030-200201 rB 5/22/14 Page 4 of 4 Model 510 / 610 Series In-Building Amplifier Sample Model

westell .com

General Information• Alphanumeric user interface

• Integrated digital power/AGC meter allows for precise set up without test equipment

• Oscillation detection and suppression control feature to prevent network interference

• Each band is independently controlled

• Local alarm contact closure points and interface for remote shutdown

Gain Options• 51062: 65 dB of Gain

• 51065: 65 dB of Gain

• 51075: 75 dB of Gain

• 51080: 80 dB of Gain

• 61080: 80 dB of Gain

Typical Applications• Parking Garages

• Warehouses

• Basements

• Shielded Structures

• Metal Buildings

• Office Complexes

• Campus Environments

• Hospitals and Convention Centers

General DescriptionThe model 510 and 610 series of in-building amplifiers provide amplification of both uplink and downlink wireless signals in facilities located within reasonable proximity of cell sites and where wireless coverage is otherwise non-existent.

Model 510 / 610 Series In-Building Amplifier

Page 1 of 4

Model Type/Band Combinations/Gain Values

51062/51065 51075 51080 61080

Single Band C, PS7, PS8, P C, PS7, PS8, P PS8 C, PS8, P

Dual Band C/P, PS8/S9 C/P, PS8/S9 - C/P, P/P, P/S9

Gain (dB) 65 75 80 80

*Refers to available band combinations by model

Band Designation*

C Cellular 850

PS7 SMR 700

PS8 SMR 800

P PCS 1900

S9 SMR 900

Page 2: Model 510 / 610 Series In-Building Amplifiersupport.westell.com/documents/030-200201 rB...030-200201 rB 5/22/14 Page 4 of 4 Model 510 / 610 Series In-Building Amplifier Sample Model

westell .com

Model 510 / 610 Series In-Building Amplifier

Page 2 of 4

Electrical Specifications

51062/065/075 51080 61080

Linear Output Power (typical)

Cellular 27 dBm - 30

SMR 7001 27 dBm 26 29

SMR 800 27 dBm - 26

PCS 22 dBm - 26

SMR 900 27 dBm - -

Noise Figure (typical) 5.5 dB 5.5 dB 5.5 dB

AGC Dynamic Range 25 dB 25 dB 5.5 dB

Propagation Delay <250 nsec <250 nsec <250 nsec

Maximum Input Power +10 dBm +10 dBm +10 dBm

Gain Adjustment Range 0–30 dB, 1dB Steps 0–30 dB, 1dB Steps 0–30 dB, 1dB Steps

Mechanical Specifications

Power Requirements 120 VAC @ 1.3 A

Dimensions

Single Band 12.38 x 12.6 x 6.21 in.

Dual Band 16.6 x 17.88 x 7.67 in.

Weight

Single Band 15.5 lbs nominal

Dual Band 19 lbs nominal

Connectors N-Female

Operating Temperature -22 to +118 (F)

Dual Passband Notch2 Special Configuration

1SMR 700 units are not available in dual band configurations.2Separate mounting for notch filters required. Contact Westell for configuration information.

Page 3: Model 510 / 610 Series In-Building Amplifiersupport.westell.com/documents/030-200201 rB...030-200201 rB 5/22/14 Page 4 of 4 Model 510 / 610 Series In-Building Amplifier Sample Model

westell .com

Model 510 / 610 Series In-Building Amplifier

Page 3 of 4

Sample Model Numbers/Frequency Ranges

LINEAR GAINLINEAR OUTPUT POWER

65 dB 0.5 Watt

75 dB0.5 Watt

80dB1 Watt

SINGLE BAND CONTIGUOUS 800 or 900 MHz

Cellular A Band 824-835 & 869-880 CSI-BDA51062-CA CSI-BDA51075-CA CSI-BDA61080-CA

Cellular B Band 835-849 & 880-894 CSI-BDA51062-CB CSI-BDA51075-CB CSI-BDA61080-CB

Cellular Full Band* 824-849 & 869-894 CSI-BDA51062-C CSI-BDA51075-C CSI-BDA61080-C

SMR 700 794-806 & 764-776 CSI-BDA51065- P7 CSI-BDA51080-P72 CSI-BDA61080-P7

SMR 800 IDEN 806-821 & 851-866 CSI-BDA51062-S8i CSI-BDA51075-S8i CSI-BDA61080-S8i

SMR 800 Full Band 806-824 & 851-869 CSI-BDA51062-S8 CSI-BDA51075-S8 CSI-BDA61080-S8

SMR 900 Band 896-901 & 935-940 CSI-BDA51062-S9 CSI-BDA51075-S9 CSI-BDA61080-S9

Paging 929-931 CSI-BDA51060-P9 CSI-BDA51075-P9 CSI-BDA61080-P9

LINEAR GAINLINEAR OUTPUT POWER

65 dB 0.5 Watt

75 dB0.5 Watt

80dB1 Watt

SINGLE BAND CONTIGUOUS PCS 1900 or DCS 1800

PCS A Block 1850-1865 & 1930-1945 CSI-BDA51062-PA CSI-BDA51075-PA CSI-BDA61080-PA

PCS B Block 1870-1885 & 1950-1965 CSI-BDA51062-PB CSI-BDA51075-PB CSI-BDA61080-PB

PCS C Block 1895-1910 & 1975-1990 CSI-BDA51062-PC CSI-BDA51075-PC CSI-BDA61080-PC

PCS D Block 1865-1870 & 1945-1950 CSI-BDA51062-PD CSI-BDA51075-PD CSI-BDA61080-PD

PCS E Block 1885-1890 & 1965-1970 CSI-BDA51062-PE CSI-BDA51075-PE CSI-BDA61080-PE

PCS F Block 1890-1895 & 1970-1975 CSI-BDA51062-PF CSI-BDA51075-PF CSI-BDA61080-PF

PCS A & D Block 1850-1870 & 1930-1950 CSI-BDA51062-PAD CSI-BDA51075-PAD CSI-BDA61080-PAD

PCS B & E Block 1870-1890 & 1950-1970 CSI-BDA51062-PBE CSI-BDA51075-PBE CSI-BDA61080-PBE

PCS F & C Block 1890-1910 & 1970-1990 CSI-BDA51062-PFC CSI-BDA51075-PFC CSI-BDA61080-PFC

PCS E & F Block 1885-1895 & 1965-1975 CSI-BDA51062-PEF SI-BDA51075-PEF CSI-BDA61080-PEF

PCS B, E, & F Block 1870-1895 & 1950-1975 CSI-BDA51062-PBEF CSI-BDA51075-PBEF CSI-BDA61080-PBEF

PCS D, B, & E Block 1865-1890 & 1945-1970 CSI-BDA51062-PDBE CSI-BDA51075-PDBE CSI-BDA61080-PDBE

PCS E, F, & C Block 1885-1910 & 1965-1990 CSI-BDA51062-PEFC CSI-BDA51075-PEFC CSI-BDA61080-PEFC

PCS D, B, E, & F Block 1865-1895 & 1945-1975 CSI-BDA51062-PDBEF CSI-BDA51075-PDBEF CSI-BDA61080-PDBEF

PCS Full Band1 1850-1910 & 1930-1990 CSI-BDA51062-P CSI-BDA51075-P CSI-BDA61080-P

1 Dimensions/weight is equivalent to a Dual Band/Dual Passband BDA.2 0.5 Watt 80dB gain BDA

* 75 dB of gain for Dual Passband 61080 PCS/PCS units.

Page 4: Model 510 / 610 Series In-Building Amplifiersupport.westell.com/documents/030-200201 rB...030-200201 rB 5/22/14 Page 4 of 4 Model 510 / 610 Series In-Building Amplifier Sample Model

Copyright © 2015 by Westell, Inc. All Rights Reserved. Westell, ClearLink, Kentrox, and Optima Management System are registered trademarks of Westell, Inc. All other names are trademarks of their respective owners. Information is correct at time of printing and is subject to change without notice. Westell, Inc. is an Equal Opportunity/Affirmative Action employer.

westell .com

030-200201 rB 5/22/14

Page 4 of 4

Model 510 / 610 Series In-Building Amplifier

Sample Model Numbers/Frequency Ranges

LINEAR GAINLINEAR OUTPUT POWER

65 dB 0.5 Watt

75 dB0.5 Watt

80dB1 Watt

DUAL PASSBAND NON-CONTIGUOUS 800 or 900 MHz

Cellular A Notched 824-835/845-846.5 & 869-880/ 890-891.5

CSI-BDA51062-CAN CSI-BDA51075-CAN CSI-BDA61080-CAN

Cellular B Notched 835-845/846.5-849 & 880-890/ 891.5-894

CSI-BDA51062-CBN CSI-BDA51075-CBN CSI-BDA61080-CBN

PCS A & C Block 1850-1865/1930-1945 & 1895-1910/ 1975-1990

CSI-BDA51062-PAC CSI-BDA51075-PAC CSI-BDA61080-PAC

PCS D & E Block 1865-1870/1945-1950 & 1885-1890/ 1965-1970

CSI-BDA51062-PDE CSI-BDA51075-PDE CSI-BDA61080-PDE

DUAL BAND* 800 or 900 MHz and PCS 1900 or DCS 1800

Cellular Full Band/ PCS Full Band

824-849/869-894 & 1850-1910/ 1930-1990

CSI-BDA51062-C/P CSI-BDA51075-C/P CSI-BDA61080-C/P

Cellular A Band/ PCS A Block

824-835/869-880 & 1850-1865/ 1930-1945

CSI-BDA51062-CA/PA CSI-BDA51075-C/A/PA CSI-BDA61080-CA/PA

Cellular B Band/ PCS C5 Block

835-849/880-894 & 1905-1910/ 1985-1990

CSI-BDA51062-CB/PC5 CSI-BDA51075-CB/PC5 CSI-BDA61080-CB/PC5

SMR 800/SMR 900 806-824/851-869 & 896-901/935-940 CSI-BDA51062-S8/S9 CSI-BDA51075-S8/S9 CSI-BDA61080-S8/S9

* 75 dB of gain for Dual Passband 61080 PCS/PCS units.