18
Installation Manual MONISAFE 400A System V01.00.00 (2013.11.08) © Nautilus Hyosung, Inc. All Rights Reserved.

Monisafe400A-Installation manual V01.00.00. · Hyosung Inc. Some of the information in this manual may differ according to the network processor to be connected and may be subsequently

  • Upload
    others

  • View
    5

  • Download
    5

Embed Size (px)

Citation preview

Page 1: Monisafe400A-Installation manual V01.00.00. · Hyosung Inc. Some of the information in this manual may differ according to the network processor to be connected and may be subsequently

Installation Manual MONISAFE 400A System

V01.00.00 (2013.11.08)

© Nautilus Hyosung, Inc. All Rights Reserved.

Page 2: Monisafe400A-Installation manual V01.00.00. · Hyosung Inc. Some of the information in this manual may differ according to the network processor to be connected and may be subsequently

© Nautilus Hyosung, Inc. All Rights Reserved. I

Revision History

Installation Manual – MONISAFE 400A System

No. Version Date Description of Change Chapter

1 V01.00.00 2013/11/08 New Publication All

© Nautilus Hyosung All Rights Reserved. The content of this specification is protected by copyright laws. 2013. 11. 08. 1st Release

Page 3: Monisafe400A-Installation manual V01.00.00. · Hyosung Inc. Some of the information in this manual may differ according to the network processor to be connected and may be subsequently

© Nautilus Hyosung, Inc. All Rights Reserved. II

Contents

Chapter1. Preface ............................................................................................................................. 1-1 Purpose ......................................................................................................................................................... 1-1 Audience ....................................................................................................................................................... 1-1 Support Information ....................................................................................................................................... 1-1 What is in This Manual................................................................................................................................... 1-1 Conventions ................................................................................................................................................... 1-2 Abbreviations of ATM ..................................................................................................................................... 1-2 Safety Precautions ......................................................................................................................................... 1-4 Related Document ......................................................................................................................................... 1-6

Chapter2. Introduction ..................................................................................................................... 2-1 Basic Features .............................................................................................................................................. 2-1

Chapter3. Installation Information .................................................................................................. 3-1 Installation Condition and Space ................................................................................................................... 3-1 ATM Dimensions ........................................................................................................................................... 3-2 Recommended Installation and Service Clearance ...................................................................................... 3-3

Chapter4. System Information ........................................................................................................ 4-1 Unpacking the ATM ....................................................................................................................................... 4-1 Installing the ATM .......................................................................................................................................... 4-2

Memo ......................................................................................................................................... Memo-1

Page 4: Monisafe400A-Installation manual V01.00.00. · Hyosung Inc. Some of the information in this manual may differ according to the network processor to be connected and may be subsequently

Installation Manual Chapter1.Preface

© Nautilus Hyosung, Inc. All Rights Reserved. 1-1

Chapter1. Preface Purpose ► This manual is produced to provide the guidelines for installers to comply with while

installing it. ► This manual describes how to prepare for and to proceed the installation of MONISAFE

400A in advance. Audience ► This manual is for persons related to installing MONISAFE 400A in branches of banks,

such as designers and construction workers of the branches and ATM installers, to work efficiently and conveniently.

Support Information

► If any question or installation error occurs while preparing for and installing MONISAFE 400A in compliance with this manual, please contact maintenance staffs of Nautilus Hyosung Inc. For the contact of maintenance staffs of Nautilus Hyosung Inc, see the E-mail addresses and telephone numbers provided separately.

What is in This Manual

► This manual is designed to provide the installation guide for the MONISAFE 400A and the detailed description of the following:

▪ Important Warnings ▪ Information for installation ► All measurements in this manual are in inch scale and [ ] is metric.

► All information described in this manual is a licensed product of Nautilus

Hyosung Inc.

Some of the information in this manual may differ according to the network processor to be connected and may be subsequently updated by the bank’s needs or the improvement by Nautilus Hyosung Inc.

It is the policy of Nautilus Hyosung Inc to improve products as new technology, components, software, and firmware become available. Therefore Nautilus Hyosung Inc. reserves the right to change specifications without notice.

Page 5: Monisafe400A-Installation manual V01.00.00. · Hyosung Inc. Some of the information in this manual may differ according to the network processor to be connected and may be subsequently

Installation Manual Chapter1.Preface

© Nautilus Hyosung, Inc. All Rights Reserved. 1-2

Conventions ► Terminologies

In this document the terminology listed below is used as follows:

▪ Customer and consumer refer to any person who transacts business through the ATM.

▪ Device and unit refer to the standard and optional ATM equipment, such as monitor, card reader, printer and dispenser. ▪ Fascia refers to the entire front portion of the unit, including the portion where the customer transacts business. ▪ Module refers to a plug-in device that can be serviced or replaced. ▪ Note(s) and bill(s) refer to the individual documents loaded into and dispensed from the dispenser. ▪ Servicing and maintenance refer to the supervisor, operator and technician’s tasks performed to keep the ATM operational. ▪ Screen refers to the text appearing on the customer display.

Abbreviations of ATM

► In this document the abbreviations listed below is used as follows:

# Abbreviations Description

1 AD board Analog Digital Board

2 ADA The American Disabilities Act

3 AP Application Program

4 Assy Assembly

5 BRM Bill Recycle Machine

5-1 BC Bill Checker

5-2 BMD Body Module-Down (Lower Body of the Module)

5-3 BMU Body Module-Up (Upper Body of the Module)

5-4 BRM Bill Recycle Machine

5-5 CSM Customer Service Module

5-6 DPC Deposit Cassette

5-7 RC Recycle Cassette

5-8 RJC Reject Cassette

5-9 TE Tape Escrow

5-10 UTC Utility Cassette

6 BATT S/W Battery Switch

7 CAM Camera Unit

Page 6: Monisafe400A-Installation manual V01.00.00. · Hyosung Inc. Some of the information in this manual may differ according to the network processor to be connected and may be subsequently

Installation Manual Chapter1.Preface

© Nautilus Hyosung, Inc. All Rights Reserved. 1-3

# Abbreviations Description

8 CE Control Electronics

9 EP Elementary Program

10 H/W Hardware

11 I/F Interface

12 LCD Liquid Crystal Display

13 OPL Operation Panel for Customers to Operate

14 OSD board On Screen Display Board

15 P/S Power Supply

16 PNC Panel Control Board

17 S/W Switch

18 SIU Sensor and Indications Unit

19 SP Service Provider

20 TTU Text Terminal Unit (OPL or SPL)

Page 7: Monisafe400A-Installation manual V01.00.00. · Hyosung Inc. Some of the information in this manual may differ according to the network processor to be connected and may be subsequently

Installation Manual Chapter1.Preface

© Nautilus Hyosung, Inc. All Rights Reserved. 1-4

Safety Precautions

► Common Safety Precaution

▪ Safety Precautions in outlined this manual provide information on safe and proper

handling of the product. Non-compliance of the safety precautions may result in injury or damage to the product.

▪ This precaution symbol with sample term tells you safety warnings during equipment handlings.

► Please read the following instructions before operating equipment.

▪ Operate equipment in the order outlined in this manual. ▪ Follow precautions indicated in this manual, as well as the equipment itself.

Failure to properly address these precautions may lead to injury or damage to the product. ▪ Avoid operations not addressed in this manual. ▪ If you cannot remedy system problems using the methods outlined in this manual, please refer to contact information listed in the manual. ▪ Any change or modifications in construction of this device which are not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

<Note!> This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

► CAUTION

1. To reduce the risk of fire, use only No. 26 AWG OR LARGER Telecommunication cord

2. Risk of explosion if battery is replaced by an incorrect type. Dispose used batteries according to the instructions. 3. For pluggable equipment, the socket-outlet shall be installed near the equipment and

shall be easily accessible. 4. The equipment is to be secured to he building structure before operation 5. A security container shall be permitted to optionally be provided with a secondary

lock, but improper use of the secondary lock feature will reduce the security level of the ATM.

Page 8: Monisafe400A-Installation manual V01.00.00. · Hyosung Inc. Some of the information in this manual may differ according to the network processor to be connected and may be subsequently

Installation Manual Chapter1.Preface

© Nautilus Hyosung, Inc. All Rights Reserved. 1-5

► Description of Precaution Symbols # Symbol Description 1 Electrical Shock Warning

▪ Do not remove cover. Only a maintenance engineer is allowed to open the cover. ▪ Do not touch. You may receive electric shock. ▪ Make sure to turn off the power when servicing the equipment.

2 High Temperature Warning ▪ Do not touch the equipment when it is running. ▪ The equipment can get extremely hot and may cause a burn. ▪ Make sure to close the cover before running the equipment.

3 Use Precaution when Moving ▪ The equipment is heavy. Make sure at least 2 people lift or move the equipment. ▪ Do not attempt to move the equipment alone. You may be injured from dropping the heavy equipment.

4 Fire Hazard ▪ Place the equipment in an area away from any combustible materials. ▪ The equipment may catch on fire from overheating or short circuit of the power supply unit.

5 Disassembly Warnings ▪ Do not disassemble or modify the equipment unless you are a certified engineer. ▪ Contact the service center for maintenance, adjustments and repairs. ▪ Improper disassembly may cause fire or electrical shock.

6 Collapse Precautions ▪ Do not place the equipment where the floor cannot sustain the weight of the equipment, or on slanted or unstable surface. ▪ Equipment may fall and cause injury or damage.

7 Unplug the Equipment ▪ Stop using the equipment immediately if it smokes, emits an unusual smell, makes abnormal sounds, or if liquids or other foreign materials enter the equipment. ▪ If the above-mentioned abnormalities occur, immediately turn off the power, unplug the equipment and contact the service center. ▪ If you ignore these symptoms, the equipment may catch on fire or cause electric shock.

Page 9: Monisafe400A-Installation manual V01.00.00. · Hyosung Inc. Some of the information in this manual may differ according to the network processor to be connected and may be subsequently

Installation Manual Chapter1.Preface

© Nautilus Hyosung, Inc. All Rights Reserved. 1-6

Related Document

► The related documents are listed as follows. If needed, please contact staffs of our technical support team and maintenance team.

▪ Operator Manual ▪ Service Manual ▪ VDM Manual ▪ Error Code Manual

► For the contact of maintenance staffs of Nautilus Hyosung Inc, see the E-mail

addresses and telephone numbers provided separately.

Page 10: Monisafe400A-Installation manual V01.00.00. · Hyosung Inc. Some of the information in this manual may differ according to the network processor to be connected and may be subsequently

Installation Manual Chapter2. Introduction

© Nautilus Hyosung, Inc. All Rights Reserved. 2-1

Chapter2. Introduction Basic Features

▶ Important features of MONISAFE400A is highlighted in the following list:

Main Controller

CPU Intel ATOM N450 1.66Ghz

Memory 1GB Up to 2GB

HDD 3.5”, 320GB SATA Type

Operating System Windows XP Professional SP3

ODD N/A

Graphic Embedded Gen3.5+GFX Core 800 X 480

PCI Slot 2 Slot

Serial Ports 6 Ports

SATA 2 Ports

USB Ports 4 + 4 Ports USB 2.0(User Port : 4EA)

LAN Gigabit LAN On-Boarded

POWER 12V

Customer Operation

LCD Type 7” Wide TFT LCD 600cd/m2

Input Method Register type TouchScreen USB Type

Bill Recycling Module

Interface Type USB 1.1(Main), USB 2.0(BC)

Sutter type Automatic Shutter 1 Slot

Functional Architecture 6 Recycle / 1 Reject / 1 Utility

Cassette

Dispense

Denomination 6 Denomination

(1, 5, 10, 20, 50 , 100 USD) 6 Recycle CST

Dispense MAX 200 bills per Transaction

Method Bundle

Deposit

Denomination 6 Denomination

(1, 5, 10, 20, 50 , 100 USD) 6 Recycle CST

Input MAX 200 bills per Transaction

Method Bundle

Cassette

Install Max Reflux 15,150 bills

Non-Reflux 16,400

Dispense CST Reflux 2,750 per Cassette

Non-Reflux 3,000 per Cassette

Deposit CST

Page 11: Monisafe400A-Installation manual V01.00.00. · Hyosung Inc. Some of the information in this manual may differ according to the network processor to be connected and may be subsequently

Installation Manual Chapter2. Introduction

© Nautilus Hyosung, Inc. All Rights Reserved. 2-2

Dispensing Speed 8 notes/sec

Power Supply

Main Power

Input Voltage /Current

100~127Vac ±10% / 13.5A 200~240Vac ±10% / 6.5A

Frequency 47~63Hz NORMAL:50/60Hz

Battery N/A

Safety & Security

Specification UL291 Level-1 Safety

Locking device Cencon Lock

Additional Function

Teller Hold Indicator Left, Right

Door Sensor Safety 1EA

Interface 2 USB, 2 Serial, 1 TCP/IP

Temp, Vibration Sensor 1EA <Note!> * is reference value when the bill thickness is 0.1 mm (0.0039 inch).

Page 12: Monisafe400A-Installation manual V01.00.00. · Hyosung Inc. Some of the information in this manual may differ according to the network processor to be connected and may be subsequently

Installation Manual Chapter3. Installation Information

© Nautilus Hyosung, Inc. All Rights Reserved. 3-1

Chapter3. Installation Information Installation Condition and Space

► When you determine the location of your MONISAFE 400A ATM, ensure that the physical environment, including the temperature and humidity, meets the requirements.

Following conditions should be met before installing equipment. 1. Avoid locations where intense direct light is reflected off the LCD screen. 2. Avoid locations where strong static electricity can occur. 3. The floor must allow easy wheelchair access from the front or the side. 4. Space required for servicing the machine should be considered before installation.

► Temperature & Humidity

Temperature Operating

5 C ~ 40 C ( 41℉ ~ 104℉)

10 C / H

In Storage -10 C ~ 60 C (14℉ ~ 140℉)

15 C / H

Humidity Operating 25% ~ 85% 10% / H

In Storage 10% ~ 90% 10% / H ► Power Supply

Main Power Input Voltage /

Current 100~127Vac ±10% / 13.5A 200~240Vac ±10% / 6.5A

Frequency 47~63Hz NORMAL:50/60Hz

Page 13: Monisafe400A-Installation manual V01.00.00. · Hyosung Inc. Some of the information in this manual may differ according to the network processor to be connected and may be subsequently

Installation Manual Chapter3. Installation Information

© Nautilus Hyosung, Inc. All Rights Reserved. 3-2

ATM Dimensions

► The figure below shows the dimensions of MONISAFE 400A ATM.

Page 14: Monisafe400A-Installation manual V01.00.00. · Hyosung Inc. Some of the information in this manual may differ according to the network processor to be connected and may be subsequently

Installation Manual Chapter3. Installation Information

© Nautilus Hyosung, Inc. All Rights Reserved. 3-3

Recommended Installation and Service Clearance

► Following diagrams are describing the recommended areas required for installing and servicing the MONISAFE 400A. (Plan View)

<Note!>

Hyosung recommends it is more convenient for your service personnel to have enough maintenance space as described below to service this ATM machine

Page 15: Monisafe400A-Installation manual V01.00.00. · Hyosung Inc. Some of the information in this manual may differ according to the network processor to be connected and may be subsequently

Installation Manual Chapter3. Installation Information

© Nautilus Hyosung, Inc. All Rights Reserved. 3-4

▶ Following diagram is describing the recommended areas required for installing and servicing the MONISAFE 400A.

Page 16: Monisafe400A-Installation manual V01.00.00. · Hyosung Inc. Some of the information in this manual may differ according to the network processor to be connected and may be subsequently

Installation Manual 4. System Installation

© Nautilus Hyosung, Inc. All Rights Reserved. 4-1

Chapter4. System Installation Unpacking the ATM

► Unpack the machine on top of the palette. 1. Cut the straps that are fastened around the box with a knife.

(Be careful when cutting the straps. Refer to figure below.) 2. Use an appropriate tool to remove the nails from the palette. (Refer to figure below) 3. Remove the lid, and then box from the top. Do not discard the packaging materials

until you have verified any shipping damage claim. Contact your distributor immediately if you see any shipping damage. Store the box in a safe place to re-use or discard of appropriately.

4. Verify the contents carefully with the packing list to be sure all items listed are included. Notify your distributor of any shortages.

5. If only the palette needs to be removed, lift the whole machine from the bottom and set it aside.

Page 17: Monisafe400A-Installation manual V01.00.00. · Hyosung Inc. Some of the information in this manual may differ according to the network processor to be connected and may be subsequently

Installation Manual 4. System Installation

© Nautilus Hyosung, Inc. All Rights Reserved. 4-2

Installing the ATM

► Installing the ATM 1. Move the ATM at the installed location safely and unpack it. 2. Take out the key from supplementary box and open the lower front door with it. 3. Input a default password to open the security door, and change the password

immediately. 4. Remove any packing materials and dry pack inside security door. 5. Take out the cassette from supplementary box, replenish the notes into each

cassette, and mount them into the BRM. 6. Open the upper front door with key and remove any packing materials and dry pack.7. Connect the Power Cord and LAN Cable to each outlet and turn power on. PRECAUTION: MONISAFE 400A machine is heavy equipment and can cause injuries

if not handled with caution. Read the following carefully. ▪ Firmly close the vault door and lock the door by turning the knob completely. ▪ Only experienced staff members should move the heavy machine. ▪ Do not tilt the ATM when moving.