OUR REF : 1905-22 Page 1 of 17 MORONEY BUILDINGWISE PTY LTD A.T.F: Moroney Family Trust INSPECTIONS 203 LAMBTON ROAD PHONE: 02 4957 8187 NEW LAMBTON 2305 E-mail: [email protected] www.buildingwise.com.au ABN: 99 887 297 684 OUR REF: 1905-22 DATE: 07.05.2019 PRE-SALE BUILDING INSPECTION STANDARD REPORT (Australian Standards No 4349.1 - 2007) ON DWELLING: 18 Scholey Street MAYFIELD, NSW FOR: Vince Owen & Emma Rudkin View of the main dwelling.

MORONEY BUILDINGWISE PTY LTD · 2019-05-13 · MORONEY BUILDINGWISE PTY LTD A.T.F: Moroney Family Trust INSPECTIONS 203 LAMBTON ROAD PHONE: 02 4957 8187 NEW LAMBTON 2305 E-mail: [email protected]

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: MORONEY BUILDINGWISE PTY LTD · 2019-05-13 · MORONEY BUILDINGWISE PTY LTD A.T.F: Moroney Family Trust INSPECTIONS 203 LAMBTON ROAD PHONE: 02 4957 8187 NEW LAMBTON 2305 E-mail: inspect@buildingwise.com.au

OUR REF : 1905-22 Page 1 of 17

MORONEY BUILDINGWISE PTY LTD

A.T.F: Moroney Family Trust

INSPECTIONS 203 LAMBTON ROAD PHONE: 02 4957 8187

NEW LAMBTON 2305 E-mail: [email protected]

www.buildingwise.com.au

ABN: 99 887 297 684

OUR REF: 1905-22

DATE: 07.05.2019

PRE-SALE BUILDING INSPECTION STANDARD REPORT

(Australian Standards No 4349.1 - 2007)

ON DWELLING: 18 Scholey Street

MAYFIELD, NSW

FOR: Vince Owen & Emma Rudkin

View of the main dwelling.

Page 2: MORONEY BUILDINGWISE PTY LTD · 2019-05-13 · MORONEY BUILDINGWISE PTY LTD A.T.F: Moroney Family Trust INSPECTIONS 203 LAMBTON ROAD PHONE: 02 4957 8187 NEW LAMBTON 2305 E-mail: inspect@buildingwise.com.au

OUR REF : 1905-22 Page 2 of 17

Inspection of the dwelling revealed it to be constructed from subfloor masonry walls & piers,

concrete piers & timber floor, wall & roof frames.

The dwelling is clad externally with timber weatherboards & the roof is lined with terracotta

tiles.

Inspection of the dwelling revealed it to be in a sound structural condition with no significant

defects evident in the dwelling’s framing components.

Observations made during the course of my inspection applicable on Tuesday 7th May 2019,

were as follows;

The dwelling is facing approximately south to the street frontage.

For the purpose of this report the dwelling is facing south.

INTERNAL

1 – Entry

The entry is in good order.

There is no insect screen door installed. This is evident to all doors throughout the dwelling.

One door handle is missing on the linen built-in cupboard.

2 – Hall The hallway is in good order.

There are only battery operated smoke alarm devices installed to alert occupants in adjacent

bedrooms in the event of a fire.

3 – Bedroom 1 (front south-west)

The bedroom is in good order.

Window insect screens are missing & this is evident to all windows throughout the dwelling.

4 – Bedroom 2 (front south-east)

The bedroom is in good order.

5 – Bathroom

The bathroom is in good order.

The bathroom is serviced by a bathtub, vanity unit, shower recess & toilet & cistern.

The shower recess waterproofing membrane was water tested. Evidence in the subfloor area

revealed water is not escaping & the membrane at present is adequate.

The bathroom door requires a new locking device.

Page 3: MORONEY BUILDINGWISE PTY LTD · 2019-05-13 · MORONEY BUILDINGWISE PTY LTD A.T.F: Moroney Family Trust INSPECTIONS 203 LAMBTON ROAD PHONE: 02 4957 8187 NEW LAMBTON 2305 E-mail: inspect@buildingwise.com.au

OUR REF : 1905-22 Page 3 of 17

6 – Bedroom 3 (centre east)

The bedroom is in good order.

There is a minor variation in the floor frame level sloping down towards the north-east

corner, as a result of pier & footing settlements.

(Pier & footing settlements are caused by moisture changes in foundation soils resulting in

expansion & contraction. As the foundation soils become saturated or dry quickly the weight

of the building causes the structure to settle downwards. Pier & footing settlements are

common to a home of this age especially with minimal site drainage provisions installed

around the perimeter of the building. Variations in floor levels are evident throughout the

building.)

7 – Lounge Room

The lounge room is in good order.

8 – Kitchen

The kitchen & kitchen cupboards are in good order.

A section of the kitchen was originally a load bearing wall & has been removed in

modifications. There is no deflection in the new structural roof beam. Therefore due to long-

term performance modifications in removing a load bearing wall are structurally adequate.

9 – Laundry

The laundry is located in a cupboard adjacent to the kitchen.

The laundry is serviced by a washtub & cabinet & in good order.

10 – Living Room (rear north)

The living room is in good order.

Page 4: MORONEY BUILDINGWISE PTY LTD · 2019-05-13 · MORONEY BUILDINGWISE PTY LTD A.T.F: Moroney Family Trust INSPECTIONS 203 LAMBTON ROAD PHONE: 02 4957 8187 NEW LAMBTON 2305 E-mail: inspect@buildingwise.com.au

OUR REF : 1905-22 Page 4 of 17

Shower recess waterproofing membrane was water tested & in good order.

Minor variation in the floor frame level sloping down towards the north-east corner of bedroom 3, as a

result of pier & footing settlements.

Page 5: MORONEY BUILDINGWISE PTY LTD · 2019-05-13 · MORONEY BUILDINGWISE PTY LTD A.T.F: Moroney Family Trust INSPECTIONS 203 LAMBTON ROAD PHONE: 02 4957 8187 NEW LAMBTON 2305 E-mail: inspect@buildingwise.com.au

OUR REF : 1905-22 Page 5 of 17

Previous load bearing wall removed in the kitchen area. There is no deflection in the new structural roof

beam.

Page 6: MORONEY BUILDINGWISE PTY LTD · 2019-05-13 · MORONEY BUILDINGWISE PTY LTD A.T.F: Moroney Family Trust INSPECTIONS 203 LAMBTON ROAD PHONE: 02 4957 8187 NEW LAMBTON 2305 E-mail: inspect@buildingwise.com.au

OUR REF : 1905-22 Page 6 of 17

EXTERNAL

11 – Rear Deck

The rear deck is constructed from timber floor frame & is structurally adequate.

There is a rear awning constructed from timber posts & roof frame & is structurally adequate.

The entrance steps are not compliant with current building requirements, as the steps have

excessive riser height exceeding 190mm. Therefore care should be taken when using these

steps.

12 – Side Entry

The side entry is in good order.

Side entry steps have an excessive riser height exceeding 190mm. Therefore care should be

taken when descending from the building.

13 – Gutters

Metal gutters are in good order.

Gutters on the eastern side have minor impact damage.

Gutters on the rear western side have dislodged from the fascia-boards & need to be

repositioned.

14 – Downpipes

PVC & metal downpipes are in good order.

15 – Fascia

Timber fascia-boards are in reasonable condition.

Several fascia-boards exhibit fungal decay at end sections, requiring ongoing maintenance &

painting.

16 – Eaves

Asbestos eaves linings are in good order, well covered with paint & not deemed to present

being a health risk.

17 – Wall Sheets

Gable end wall sheets are fibre-cement & in good order.

18 – Weatherboards

Timber weatherboards are in good order.

19 – Windows

Timber window frames are in good order.

Page 7: MORONEY BUILDINGWISE PTY LTD · 2019-05-13 · MORONEY BUILDINGWISE PTY LTD A.T.F: Moroney Family Trust INSPECTIONS 203 LAMBTON ROAD PHONE: 02 4957 8187 NEW LAMBTON 2305 E-mail: inspect@buildingwise.com.au

OUR REF : 1905-22 Page 7 of 17

20 – Roof Tiles

Terracotta roof tiles are in good order.

Barge & ridge capping tiles in a maintenance program would benefit by being repointed with

new cement mortar.

The lead flashings on top of the roof tiles in under the gable wall linings at the rear of the

building require ongoing maintenance & sealing.

Inspection in the roof void revealed terracotta roof tiles exhibit minor fretting only to the

underside & show no evidence of any rainwater ingress into the roof void below.

21 – Fences

Metal boundary fences are in good order.

22 – Driveway

The concrete stripped driveway is in good order.

Page 8: MORONEY BUILDINGWISE PTY LTD · 2019-05-13 · MORONEY BUILDINGWISE PTY LTD A.T.F: Moroney Family Trust INSPECTIONS 203 LAMBTON ROAD PHONE: 02 4957 8187 NEW LAMBTON 2305 E-mail: inspect@buildingwise.com.au

OUR REF : 1905-22 Page 8 of 17

SERVICES

23 – Electrical

The dwelling’s electrical wiring has earth leakage circuit breakers. It is recommended the

wiring be checked by a licensed Electrician for compliance & safety.

24 – Plumbing

All water-feeder pipes, stormwater drainage systems, sewerage drainage systems & gas

services need to be checked by a licensed Plumber for serviceability.

25 – Hot Water Unit

The instantaneous gas hot water unit appears to be in good order.

26 – Site Drainage Minimal site drainage provisions have been installed around the perimeter of the dwelling.

Page 9: MORONEY BUILDINGWISE PTY LTD · 2019-05-13 · MORONEY BUILDINGWISE PTY LTD A.T.F: Moroney Family Trust INSPECTIONS 203 LAMBTON ROAD PHONE: 02 4957 8187 NEW LAMBTON 2305 E-mail: inspect@buildingwise.com.au

OUR REF : 1905-22 Page 9 of 17

Electrical meter box has earth leakage circuit breakers. There are no termite sticker notices in the meter

box on any previous termite management systems.

Instantaneous gas hot water unit on the eastern side.

Page 10: MORONEY BUILDINGWISE PTY LTD · 2019-05-13 · MORONEY BUILDINGWISE PTY LTD A.T.F: Moroney Family Trust INSPECTIONS 203 LAMBTON ROAD PHONE: 02 4957 8187 NEW LAMBTON 2305 E-mail: inspect@buildingwise.com.au

OUR REF : 1905-22 Page 10 of 17

Page 11: MORONEY BUILDINGWISE PTY LTD · 2019-05-13 · MORONEY BUILDINGWISE PTY LTD A.T.F: Moroney Family Trust INSPECTIONS 203 LAMBTON ROAD PHONE: 02 4957 8187 NEW LAMBTON 2305 E-mail: inspect@buildingwise.com.au

OUR REF : 1905-22 Page 11 of 17

STRUCTURAL FRAMES

27 – Rear Shed

The rear shed is constructed from a concrete slab on ground & metal wall & roof frames & is

structurally adequate.

There is a wet area that has a shower recess, vanity unit & toilet & cistern & in serviceable

condition.

28 – Floor Frame

The floor frame is constructed from hardwood bearers & joists, timber tongue & groove

floorboards & suspended concrete slabs.

The floor frame due to the long-term performance is structurally adequate.

Ventilation into the subfloor area is in good order.

Ant-capping to the tops of the masonry walls & piers is inadequate & therefore it is

recommended regular pest inspections be undertaken to ensure timber destroying pests do not

enter the building undetected.

Drainage in preventing surface & seepage water from entering the subfloor area is

reasonable.

29 – Wall Frames

A full inspection of timber wall frames was not possible as the wall frames are covered by

internal wall linings & external weatherboards.

The wall frames from external inspection & due to long-term performance are structurally

adequate.

30 – Roof Frame

The roof frame is a hardwood conventional type construction (refer enclosed diagram).

Due to long-term performance of the timber roof frame it is structurally adequate.

No foil sarking has been installed to the underside of terracotta roof tiles as a secondary

moisture & thermal barrier.

The tops of the ceilings are insulated with fibreglass batts.

Page 12: MORONEY BUILDINGWISE PTY LTD · 2019-05-13 · MORONEY BUILDINGWISE PTY LTD A.T.F: Moroney Family Trust INSPECTIONS 203 LAMBTON ROAD PHONE: 02 4957 8187 NEW LAMBTON 2305 E-mail: inspect@buildingwise.com.au

OUR REF : 1905-22 Page 12 of 17

Timber floor frame.

Timber floor frame surrounding the shower recess.

Page 13: MORONEY BUILDINGWISE PTY LTD · 2019-05-13 · MORONEY BUILDINGWISE PTY LTD A.T.F: Moroney Family Trust INSPECTIONS 203 LAMBTON ROAD PHONE: 02 4957 8187 NEW LAMBTON 2305 E-mail: inspect@buildingwise.com.au

OUR REF : 1905-22 Page 13 of 17

Suspended concrete slab to the wet area.

Timber floor frame to the rear addition.

Page 14: MORONEY BUILDINGWISE PTY LTD · 2019-05-13 · MORONEY BUILDINGWISE PTY LTD A.T.F: Moroney Family Trust INSPECTIONS 203 LAMBTON ROAD PHONE: 02 4957 8187 NEW LAMBTON 2305 E-mail: inspect@buildingwise.com.au

OUR REF : 1905-22 Page 14 of 17

Timber roof frame.

Timber roof frame to the rear addition.

Page 15: MORONEY BUILDINGWISE PTY LTD · 2019-05-13 · MORONEY BUILDINGWISE PTY LTD A.T.F: Moroney Family Trust INSPECTIONS 203 LAMBTON ROAD PHONE: 02 4957 8187 NEW LAMBTON 2305 E-mail: inspect@buildingwise.com.au

OUR REF : 1905-22 Page 15 of 17

SUMMARY

The building is approximately 70 years old.

Structural condition of the building is in good order.

Cosmetic condition of the building is in good order.

The following items need attending to;

• The electrical wiring & plumbing services checked by licensed trades-people.

THIS REPORT REFERS TO THE CONDITIONS OBSERVED AT THE TIME OF

INSPECTION BASED ON VISUAL OBSERVATION AND DOES NOT INCLUDE :

1) ANY ADDITIONAL ADVICE IN RESPECTS TO PEST CONTROL.

2) ANY ADDITIONAL ADVICE IN RESPECTS TO ELECTRICAL WIRING &

PLUMBING SERVICES.

3) ANY ADDITIONAL ADVICE IN RESPECTS TO A STRUCTURAL ENGINEER,

SURVEYOR OR SOLICITOR.

4) REFERENCE TO PARTS OF THE BUILDING NOT ACCESSIBLE OR

COVERED WITH MATERIALS.

5) ANY REFERENCE AS TO WHETHER THE SITE IS CONTAMINATED

IN ANY WAY OR ANY HAZARDOUS MATERIALS.

ASBESTOS DISCLAIMER. ‘’ No inspection for asbestos was carried out at the property and

no report on the presence or absence of asbestos is provided. If during the course of the inspection

asbestos or materials containing asbestos happened to be noticed then this may be noted in the

additional comments section of the report. Buildings built prior to 1982 may have wall and/or ceiling

sheeting and other products including roof sheeting that contain asbestos. Even buildings built after

this date up until the early 90s may contain asbestos. Sheeting should be fully sealed. If concerned or

if the building was built prior to 1990 then you should seek advice from a qualified asbestos removal

expert as to the amount and importance of the asbestos present and the cost of sealing the asbestos or

removing the asbestos.

Should you have any queries relating to this report, please do not hesitate to contact me.

Phone: 02 4957 8187.

Yours faithfully

Peter J Moroney

Page 16: MORONEY BUILDINGWISE PTY LTD · 2019-05-13 · MORONEY BUILDINGWISE PTY LTD A.T.F: Moroney Family Trust INSPECTIONS 203 LAMBTON ROAD PHONE: 02 4957 8187 NEW LAMBTON 2305 E-mail: inspect@buildingwise.com.au

OUR REF : 1905-22 Page 16 of 17

DEFINITIONS (used in the) BUILDINGWISE REPORTS

Sub-standard 0-3 : A category less than “below average”. Usually implying

inadequate/inappropriate workmanship, &/or materials &/or significant deterioration evident.

Parts of the building works may not be structurally adequate/appropriate &/or may be

unsuitable for service &/or for intended use including items such as : weather tightness,

Council compliance or safety issues. Immediate/extensive rectifications or action can be

anticipated, usually work of a significant/expensive nature that may include partial

demolition or reconstruction Further investigation may be warranted. The client should obtain

written quotes for rectifications/repairs.

Below Average (Poor) 4-5 : A standard less than the definition noted in “fair/average”.

Usually implying that there may be some areas constructed not to trade standard or using

inappropriate materials &/or failing, in parts, in the aspect of serviceability/adequacy for

intended use. There may be less than a reasonable amount of prior maintenance, repairs &

renovations. Generally this definition/classification will imply that rectifications should be

carried out in the immediate short term & usually implies above average costs for

rectifications/maintenance.

Fair Average (good order) 6-8 : This definition may imply terms such as: satisfactory,

reasonable, serviceable, adequate. A standard no more than can be reasonably expected for

the age/type/standard of building, bearing in mind the acceptable building methods/materials

at the time of the original building works. Implicit in this description can be a reasonable

amount of prior maintenance/renovations/repairs, some of which may have been done by

numerous previous owners & not always to a trade standard. There may also be some general

wear, neglect, weathering, decay, corrosion, irregularities but no major/significant

deterioration or structural defects.

Rectifications/repairs would normally be scheduled as per the maintenance program.

Above Average 9-10 : A standard higher than the definitions noted in “fair/average”.

Usually implying good workmanship & materials, close attention to appropriate

maintenance/renovations/repairs. Generally this category would imply no immediate/urgent

requirements for rectifications/repairs.

Page 17: MORONEY BUILDINGWISE PTY LTD · 2019-05-13 · MORONEY BUILDINGWISE PTY LTD A.T.F: Moroney Family Trust INSPECTIONS 203 LAMBTON ROAD PHONE: 02 4957 8187 NEW LAMBTON 2305 E-mail: inspect@buildingwise.com.au

OUR REF : 1905-22 Page 17 of 17

GENERAL APPRAISAL OVERVIEW

ADDRESS : 18 Scholey Street

MAYFIELD, NSW

Scale 1 to 10 { 1 = poor, graded to 10 = excellent }

STRUCTURAL CONDITION

Floor Frame 8

Wall Frame 8

Roof Frame 8

COSMETIC CONDITION

Wet Areas 7

Kitchen 8

Internal 7

External 7

MAINTENANCE 7

SERVICE

Gutters Downpipes 7

Site Drainage 7

PROPERTY

Slope of Site 9

Vehicle Access 8

Privacy & Aspect 8

FACILITIES

Public Transport 8

Schools 8

Shops 8