INSTALLATION INSTRUCTIONSNo.59-1900-1
CDX seriesCDX series
TOP VIEW
SIDE VIEW
TOP VIEW
SIDE VIEW
DETECTION AREA3
KNOCKOUTS2
INSTALLATION HINTS1
Cornermount knockout
Mounting knockout
Cornermount knockout
Wiring knockout
COMPLIANCE How to release the unit base >>
Put up the base Remove
When using a wall tamper >>Use the knockout for a wall tamper. If the main unit is taken from the wall, the gray section will break away and stay on the wall and the tamper switch will operate. When installing on a plaster board wall or other soft material, cut out the gray area from the back plate.
Note >>
This symbol indicates prohibition.
This symbol indicates recommendation.
Grade 3 INDOOR DETECTORGrade 3 INDOOR DETECTOR
• Use both knockouts (1) and (2) with included screws. (Self tapping 3 X 16 mm: 3 pcs.)• For corner installation, use both knockouts (3) and (4) with
included screws. (Self tapping 3 X 16 mm: 3 pcs.)
• CDX series complies with following Directives / Standards.Directive: EMC Directive 2004/108/ECApplied Standards: EN 50130-4: 1995 +A1: 1998 +A2: 2003
EN 55022: 2006EN50131-1 Grades and Environmental Class:Environmental Class 2 and Security Grade 3.Applide Standards: EN 50131-2-2 (CDX-NAM / CDX-AM)
EN 50131-2-4 (CDX-DAM)• CDX DAM also complies with following Directives / Standards
marked Class II, Directive: R&TTE Directive 1999/5/ECApplied Standards: EN 300 440-1: 2009
EN 300 440-2: 2009EN 301 489-1: 2008EN 301 489-3: 2002EN 50371: 2002EN 60950-1: 2006 +A11: 2009
The following table indicates the areas of intended use of the equipment and any known restrictions. For countries not included in this list, please consult the responsible Spectrum Management Agency.
* Specifications and design are subject to change without prior notice.
SPECIFICATIONS10
FCC ID: DC9 OPMW IC: 4012A-OPMWThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.(2) This device must accept any interference received, including
interference that may cause undesired operation.
COMPLIANCE
OPTIONLED INDICATION9
LightBlink OFF
Red
LightBlink OFF
Red GreenYellow
Blinks for approx. 60 sec.
Lights for 2 sec.
Blinks 3 times and goes off for 3 sec, and repeats.
Blinks 4 times and goes off for 3 sec, and repeats.
Blinks 5 times and goes off for 3 sec, and repeats.
DETECTOR CONDITION LED INDICATOR
Warm-up
Alarm
Trouble output
Anti-masking detection
Local Self test
Low voltage detection
Remote Self test
x3 times
x4 times
x5 times
Model
Country of intended useAustriaBelgiumDenmarkFinlandFranceGreeceIrelandItaly
LuxembourgThe NetherlandsSpainSwedenUnited KingdomOther non-EU: IcelandNorwaySwitzerland
9.900GHz10.525GHz10.525GHz9.900GHz
10.587GHz10.525GHz10.587GHz10.525GHz
10.525GHz10.525GHz10.525GHz10.525GHz10.587GHz10.525GHz10.525GHz10,525GHz
Restrictions Country of intended use Restrictions
CDX-NAM CDX-AM CDX-DAM
Passive infrared Passive infrared & Microwave
EN50131-2-2 (Grade 3)
AIR type
24m × 2m (80ft. × 7ft.) narrow [20 zones]
15m × 15m (50ft. × 50ft.) 85° wide [82 zones]
9 - 18VDC
N.C. 28V DC 0.2A max.
N.C. 28V DC 0.2A max.
-10°C - +50°C (14°F - 122°F)
No alarm 10V/m
1.8 - 2.4m (6ft. - 8ft.)
180g (6.3oz)
140×70×52.3mm (5.51×2.76×2.06 inches)
95% max.
N.C. Opens when cover is removed or the wall tamper switch operates. 28V DC 0.1A max.
EN50131-2-4 (Grade 3)
17mA (normal) / 20mA (max.) at 12V DC
19mA (normal) / 26mA (max.) at 12V DC
Detection method
Detector standard Masking detection methodPIR Coverage [Detection zones]
Power supply
Alarm output
Tamper switch
Trouble output
Operating temperatureEnvironmental humidity
RF interference
Mounting height
WeightDimensions (H×W×D)
Current consumption
OPTEX CO., LTD. (JAPAN)(ISO9001 Certified) (ISO14001 Certified)5-8-12 Ogoto Otsu Shiga 520-0101 JAPANTEL: +81-77-579-8670 FAX: +81-77-579-8190URL: http://www.optex.co.jp/
OPTEX INCORPORATED (USA)TEL: +1-909-993-5770Tech: (800)966-7839URL: http://www.optexamerica.com/
OPTEX (EUROPE) LTD. (UK)TEL: +44-1628-631000URL: http://www.optex-europe.com/
OPTEX SECURITY SAS (FRANCE)TEL: +33-437-55-50-50URL: http://www.optex-security.com/
OPTEX SECURITY Sp. zo. o. (POLAND)TEL: +48-22-598-05-55URL: http://www.optex.com.pl/
OPTEX KOREA CO., LTD. (KOREA)TEL: +82-2-719-5971URL: http://www.optexkorea.com/
OPTEX (DONGGUAN) CO., LTD.SHANGHAI OFFICE (CHINA)TEL:+86-21-34600673URL:http://www.optexchina.com/
FA-1W: Wall Mount Bracket Adjustable ±45° (Horizontally), 0-20° (Vertically downwards) FA-3: Compact Wall & Ceiling Bracket Adjustable ±45°(Horizontally), 0-10° (Vertically downwards)
NOTECDX series is only a part of a complete system, therefore we cannot accept complete responsibility for any damages or other consequences resulting from an intrusion.
Anti-masking detection
Local Self test
Low voltage detection
Remote Self test
x3 times
x4 times
x5 times
Blinks for approx. 60 sec.
Lights for 2 sec.
Blinks 3 times and goes off for 3 sec, and repeats.
Blinks 4 times and goes off for 3 sec, and repeats.
Blinks 5 times and goes off for 3 sec, and repeats.
Green lights for 2 sec.
Yellow Lights for 2 sec.
DETECTOR CONDITION LED INDICATOR
Warm-up
Alarm
PIR detection
MW detection
Trouble output
• 15m (50ft.) Wide Angle with Down Zone (CDX-AM/CDX-DAM)• 24m (80ft.) Long Range (CDX-NAM)• Respected Double Conductive Shielding (CDX-AM/CDX-NAM)
- Extremely High Light and RFI Immunity• Extreme Tough Microwave Module (CDX-DAM)• PLUG-IN EOL Resistors (PEU)• Advanced IR Beam Anti-Masking Technology
Caution >>
Do not touch the microwave unit to avoid breakdown caused by static electricity.
(4) (3)
(1)(2)
CDX-AM CDX-NAM CDX-DAM
CDX-AM CDX-NAM CDX-DAM
CDX-AM CDX-NAM CDX-DAM
CDX-AM CDX-NAM CDX-DAM
CDX-AM PIR with active IR anti-masking (Grade 3)CDX-NAM CDX-AM with long and narrow lens (Grade 3)CDX-DAM PIR & Microwave with active IR anti-masking (Grade 3)
HIGH STD
M
L H
TPTPRSTLEDALCOMTRSP(–)
TAMPERTROUBLE ALARM
TPTPRSTLEDALCOMTRSP(–)(+)
TROUBLE
Grade3
CONTROL PANEL
HOW TO SET
CONNECTION OPTION
Grade2
PLUG-IN EOL ALARM TAMPER
5-1 When setting the resistance value with using PLUG-IN EOL
5-2 When setting the resistance value without using PLUG-IN EOL
SETTING6
WIRING4
PLUG-IN End Of Line resistors (EOL)5
6-2 DETECTION MODE
SP STD
OFFON
CDX-AM CDX-NAM CDX-DAM
CDX-AM CDX-NAM CDX-DAM
CDX-AM CDX-NAM CDX-DAM
CDX-AM CDX-NAM CDX-DAM
CDX-AM CDX-NAM CDX-DAM
CDX-AM CDX-NAM CDX-DAM
CDX-AM CDX-NAM CDX-DAM
CDX-AM CDX-NAM CDX-DAM
6-1 LED ON/OFF
6-3 PIR SENSITIVITY
7 (RESERVED)6 ANTI MASKING OUTPUT SELECT5 ANTI-MASKING SENSITIVITY4 ANTI-MASKING ON/OFF3 PIR SENSITIVITY2 DETECTION MODE1 LED ON/OFF
REMOTE LED (LED operation remote control) >>
Also LED can be enabled or disabled remotely from control panel by LED terminal. Ensure to set LED switch “OFF” for this setting.
LED enabled Connect LED terminal to 0 V LED disabled No ground to LED terminal (open circuit)
POSITION
STD (Factory default)
SP
Suitable for standard applications
For use in hostile areas where small animals or other objects exist such as fax machines or curtains.
FUNCTION
POSITION
STD (Factory default)
HIGH
Suitable for standard applications
Suitable for site requires greater sensitivity
FUNCTION
POSITION
OFF
ON (Factory default)
The LED lights when someone is detected.
The LED does not light even if someone is detected.
FUNCTION
Wire resistors between the appropriate terminals as follows:
Three types of signals – ALARM, TROUBLE and TAMPER – can be recognized through the combination of the resistance value and wires for the TR, COM and TP terminals.
TP
TAMPER OUTPUT
REMOTE SELF TEST
REMOTE LED
ALARM OUTPUT
COMMONTROUBLE OUTPUT
SPARE
POWER INPUT (9-18VDC)
TPRSTLEDALCOMTRSP(–)(+) MICROWAVE SENSITIVITY (6-7) (CDX-DAM only)
(+)
PLUG-IN EOL
Note>> Check the direction when inserting PLUG-IN EOL.
Caution>>• There are several types of PLUG-IN EOL and the insertion direction
differs depending on its type.
When connecting to a control panel that supports the EOL technique(Factory default)
ON OFF
OFFON
HIGH STD
M
L H
MW SENSITIVITYL M H
9m (30ft.) 12m (40ft.) 15m (50ft.)
6-5 ANTI-MASKING SENSITIVITY
6-4 ANTI-MASKING ON/OFF
6-6 ANTI-MASKING OUTPUT SELECT
If the microwave sensitivity is set too high, it may detect movements outside of the detection area, resulting in false alarms. By creating a microwave detection area to conform to the PIR detection area, it achieves higher detection performance and preventing false alarms.
6-7 MICROWAVE SENSITIVITY
7-1 LOCAL SELF TEST
7-2 REMOTE SELF TEST
SELF TEST7
TROUBLE OUTPUT SUMMARY8
CDX-DAM
When an object is placed close to the lens surface, for a period of more than 20 seconds then the Anti-Masking circuit will activate and generate a trouble signal.
Note>> “A” means activate, “N/A” means not available.
Caution>>The above distance indications are guide only. Do not set the MW sensitivity too low. This could cause a MW failure.It is important to adjust the sensitivity so that the MW and PIR detection areas are overlapping.
This function checks the operation of detection ability of PIR and Microwave. This ensures that the unit is always working correctly.
Local self test is controlled by the detector and runs periodically to test the functionality of the circuitry. If the local self test fails, the TROUBLE relay is activated and LEDs blink (see 9 ).
This test may be initiated by the control panel by applying 0V to the RST terminal. If the remote self test passes, the ALARM relay is activated for 5 seconds. If the test fails, the TROUBLE output is activated and the LEDs will blink (see 9 ).
POSITION
STD (Factory default)
HIGH
Suitable for standard applications
Suitable for site requires greater sensitivity
FUNCTION
POSITION
ON (Factory default) Enabled
OFF Disabled
FUNCTION
ON
N/A A
A A
OFF(Factory defoult)
POSITIONOUTPUT TERMINAL
ALARM TROUBLE
7-3 WALK TEST
1m
Keep at least 1 meter away from the detector and clear of any objects.
Note>> When selecting ON, functions of 6-5 and 6-6 are activated.
Anti-masking detection
Local Self test
Low voltage detection
Remote Self test
When an object is placed close to the lens surface for a period of more than 20 seconds, then the PIR Anti-Masking circuit will activate and generate a trouble signal.
Local self test is controlled by the detector and runs periodically to test the functionality of the circuitry. If the local self test fails, the TROUBLE relay is activated and LEDs blink (see 9 ).
This test may be initiated by the control panel by applying 0V to the RST terminal. If the remote self test passes, the ALARM relay is activated for 5 seconds. If the test fails, the TROUBLE output is activated and the LEDs will blink (see 9 ).
When the power supply voltage drops, the low voltage detection circuit activates and outputs TROUBLE.
The terminal that is output when anti-masking is detected can be switched with this switch.
Detector
Wall
Good
No good(Penetration)
PEU