11
THERMAX LIMITED - ENVIRO BFVer02.13.027 TECHNICAL DATA SHEET OF BAG FILTER Customer : M/s. MSN LABS Rev : 2, Dtd 06-08-13 Offer Reference : Env/BF/HO/SP/357192/Rev 2 BF 1 Units 1 Input process data for each filter 3 Quantity of filters no 1 Application Boiler Firing Type AFBC Type of Fuel Dust to be handled Flyash Gas flow rate Am3/hr 27970 Bagfilter is designed on ID fan volume basis. Gas temperature (Minimum) °C 170 Gas temperature (Maximum) °C 180 Bgfilter shall be bypassed beyond 240°C operating temperature. Gas pressure at BF inlet mmwc -200 Inlet dust load gm/Am3 34 Oxygen Content in flue gas % V/V 6 SO2 Content in flue gas % V/V 0.02 Moisture in gas % V/V 11 Type of dust (Main Characteristic) Fine Dust Min bulk density for RAV sizing Kg/m3 600 Dust Max bulk density for power Kg/m3 800 Dust size distribution 100% > 5 µ Area classification for Elect/ Instru Safe & non hazardous Technical data sheets for each filter Type of filter Pulse jet Filter mounting Structure Filter cleaning On line Gas entry Casing Design pressure (incl wind load) mmwc ± 500 Δ P across filter mmwc 175 Maximum outlet dust emission mg/Nm3 100 Offered bag height m 3.6 100 % Indian Coal / Imported Coal with 10%Moisture / Imported Coal with 20%Moisture/ 100% Rice Husk Bag filter is not designed for fouling fuels like Mustard stalk, Mustard husk, 100% Wood, Soya briquette fired in boiler / Heater, Incase these fuels fired in boiler / heater bagfilter shall be bypassed.

Msn Labs 14 Tph Boiler Bag Filter Technical Offer

  • Upload
    pavani

  • View
    3

  • Download
    1

Embed Size (px)

DESCRIPTION

mtymtmt

Citation preview

Technical offerTHERMAX LIMITED - ENVIROBFVer02.13.027 TECHNICAL DATA SHEET OF BAG FILTERCustomer : M/s. MSN LABSRev : 2, Dtd 06-08-13Offer Reference : Env/BF/HO/SP/357192/Rev 2BF 1Units1Input process data for each filter30.0Quantity of filtersno1ApplicationBoilerFiring TypeAFBCType of Fuel100 % Indian Coal / Imported Coal with 10%Moisture / Imported Coal with 20%Moisture/ 100% Rice HuskBag filter is not designed for fouling fuels like Mustard stalk, Mustard husk, 100% Wood, Soya briquette fired in boiler / Heater, Incase these fuels fired in boiler / heater bagfilter shall be bypassed.Dust to be handledFlyashGas flow rateAm3/hr27970Bagfilter is designed on ID fan volume basis.Gas temperature (Minimum)C170Gas temperature (Maximum)C180Bgfilter shall be bypassed beyond 240C operating temperature.Gas pressure at BF inletmmwc-200Inlet dust loadgm/Am334Oxygen Content in flue gas% V/V6SO2 Content in flue gas% V/V0.02Moisture in gas% V/V11Type of dust (Main Characteristic)FineDust Min bulk density for RAV sizingKg/m3600Dust Max bulk density for power Kg/m3800Dust size distribution100% > 5 Area classification for Elect/ InstruSafe & non hazardousTechnical data sheets for each filterType of filterPulse jetFilter mountingStructureFilter cleaningOn lineGas entryCasingDesign pressure (incl wind load)mmwc 500 P across filtermmwc175Maximum outlet dust emissionmg/Nm3100Offered bag heightm3.6Offered filtration aream2440.50Offered air-to-cloth ratiom3/min/m21.06Selected filterAPC-252-360SC18.000Number of bags offeredno252External painting of filter- PrimerRed OxideExternal painting filter- FinishNot in TL scopeExternal surface preparation of filterManual wire brushExternal paint spec of filter- Primer2 coats, 20 eachExternal paint spec of filter- FinishNAInternal painting of filterRed OxideInternal surface preparation of filterManual wire brushInternal paint spec of filter2 coats, 20 eachInsulation & cladding scopeNot provided by TLInsulation & cladding requirementRequiredMineral wool insulation specLRB,100 Kg/m3Mineral wool insulation thkmm75Aluminium cladding spec22 SWG plainFilter casingMOCIS 1079 Gr OThicknessmm3Condition of supplyAssembledFilter Tube sheetMOCIS 2062 Gr AThicknessmm5CuttingLaser CutBag holding methodSnap bandFilter top coversMOCIS 1079 Gr OThicknessmm3Insulation boxProvided by TLFilter HopperProvided by TLTypePyramidicalMOCIS 2062 Gr AThickness5Condition of supplyAssembledNo. of hoppersno1Hopper plate angleo65Hopper discharge openingRoundHopper HeaterProvided by TLArea coveredBottom 1/3 portionSupport structureNot Provided by TLLadder to filter topNot provided by TLRailing on filter topNot provided by TLRAVProvided by TLQuantityno1MOCCITypeAdjustable tipDrive arrangmentChain-sprocketMotor MakeTL approvedRAV rotor speedRPM20Recommended Size300PaintingHR Matte blackMotor HPHP1VoltageV AC6%415FrequencyHZ3%50Filter bagsProvided by TLFabric materialFiber glassBag lengthmm3,665Bag fabric weightgm/m2700+/-50Fabric design temperature (Max.)C240Antistatic treatmentNo treatmentFabric treatment for water/oil resistanceNo TreatmentSourceImported fabricCagesProvided by TLVertical wire diamm3.0Ring wire diamm3.0No of vertical wiresno20Number of splitsNoneCage lengthm3,650.0Cage surface treatmentHR BlackMaterial of constructionCSCage diametermm143ID FanFan not availablePulse solenoid valveProvided by TLMakeThermaxSizeinch1.5Operating voltageV AC230Quantity of PSVno18Quality of compressed air required(-)20C Dewpt,Oil 50 % in ashHigher percentage of Potassium & Chloride will form salts which will result in blinding of filter bags. Higher percentage of Chloride will result in corrosion inside bag filter

We suggest fuels like ground nut shell to be co-fired with fuel containing lesser potassium & chloride for better filter bag life Note: Bag filter is designed for above mentioned input parameters, bag filter guarantee will be null & void for any change in above input parameters.

Scope ListTHERMAX LIMITED - ENVIRODoc. No. ENV/SNP/F10Scope of supply for BagfilterCustomer : M/s. MSN LABSRev : 2, Dtd 06-08-13Offer Reference : Env/BF/HO/SP/357192/Rev 2ItemTLClientEngg supplyMakeMechanical itemsCasing assemblyXNoTL approvedTube sheetXNoTL approvedTop CoverXNoTL approvedHopper assembly with access doorXNoTL approvedSupport structure & found. boltsXYesNALadder to filter topXYesNARailings at filter topXYesNAGeared motor for RAVXNoTL approvedRAVXNoTL approvedFilter BagsXNoImported fabricCages with integral venturyXNoTL approvedID fanXNoNAID fan motorXNoTL approvedCompressed air manifold assemblyXNoTL approvedCompartment manifoldsXNoTL approvedInlet Cum Bypass Damper XNoHydro-PneumaticInlet counter flangesXNoTL approvedPaintingXNoTL approvedElectrical & Instrumentation itemsPulse & solenoid valvesXNoTL ApprovedCables for PSVXNoTL approvedJunction boxes for PSVXNoTL approvedHopper level switchXNoEIPSolid State Seq.ControllerXNoX CaliburSequential controller boxXNoTL ApprovedManometerXNoTL approvedAir filter regulatorXNoTL approvedDifferential Pressure SwitchXNoSwitzerLimit SwitchXNoJai BalajiControl Panel / MCC cum CP as mentioned in Technical offerXNoTL approvedPressure switch for air lineXNoSwitzerZero speed switchXNoJayashreeHopper heatersXNoTL approvedTICXNoSELECTRONTEXNoYog Electro devicesThermostatXNoIndfosJunction boxes for hopper heaterXNoTL approvedInsulation and claddingXNoExclusionsDust conveying beyond RAV outlet XFoundation bolts, Design/supply of all civil/structural workXAir compressor/air piping to BFXDesign/supply of all ducting, dampers, hoods, supports, etcXErection, comissioning & testing including supervisionXMotors except included above, MCC, LPBS, cabling/wiring/ accessory, cable tray/supportXEarthing, Lightning, Lightning arrestorXFinish Painting at siteXAny other item not specifically mentioned in scope of supplyX