RTN 600 MW Installation Standard 1 HCPT - HUAWEI
HCPT – HUAWEI
RTN 600 MICROWAVES
INSTALLATION STANDARD
PT. Hutchitson PT
………………………………………
Name:
Date:
PT Huawei Technologies
………………………………………
Name:
Date:
HCPT 2G & 3G TURNKEY PROJECT
2009
8/19/2019 MW RTN Installation Standard v0 1
2/14
RTN 600 MW Installation Standard 2 HCPT - HUAWEI
1. Antenna Fastness
Key Points Details DescriptionThe antenna must be
installed in the rightheight and position and
polarization
The fixation of antenna
and pole are reliable
Each screw should be fastness very well
8/19/2019 MW RTN Installation Standard v0 1
3/14
RTN 600 MW Installation Standard 3 HCPT - HUAWEI
For the more than 1.2m antenna, the side strut must be installed and fixed
position is correct.
Antenna identifier
(standard labeling)
Labeling Format:
Label template :
Font : Black
Background : White
Material : Print Label
ANTENNA TO XXX (FE ID)FAR END NAME
8/19/2019 MW RTN Installation Standard v0 1
4/14
RTN 600 MW Installation Standard 4 HCPT - HUAWEI
2. ODU Fastness
Key Points Details DescriptionThe ODU's and hybrid
coupler's appearance areproperly Tighten all screw / bolt from ODU to hybrid
IF connector from ODU should be waterproofed properly
The IF connector of ODUshould be waterproofed
and face downward
ODU Fixing
Waterproofing
Waterproofing
8/19/2019 MW RTN Installation Standard v0 1
5/14
RTN 600 MW Installation Standard 5 HCPT - HUAWEI
The ODU grounding
cable should be shortestlength as possible and
attached to bus bar
Grounding connection
to bus bar
ODU Grounding
8/19/2019 MW RTN Installation Standard v0 1
6/14
RTN 600 MW Installation Standard 6 HCPT - HUAWEI
ODU Identifier (ODU
labeling)
Labeling Format:
Label template :
For 1+1, mark ODU1 for main ODU and ODU2 for stand by ODU
Font : Black
Background : White
Material : Print Label
3. IF Distribution
Key Points Details DescriptionIn general, the IF cable
should be grounded to a
minimum of one point
IF grounding kit installed between concurrence HCT and VCT
Tower
Recommended point to
install IF roundin kit
ODU1 TO XXX (FE ID)FAR END NAME
8/19/2019 MW RTN Installation Standard v0 1
7/14
RTN 600 MW Installation Standard 7 HCPT - HUAWEI
2 end are tidy with cable tie
IF grounding kit should connect to lower VCT bus bar.
Leave enough slack when
connecting cables to the
ODU to facilitate futuremaintenance
IF redundant no more than 2 meters
IF redundant no more
than 2m
Tidy up with cable tie
Grounding kit
connect to bus bar
8/19/2019 MW RTN Installation Standard v0 1
8/14
RTN 600 MW Installation Standard 8 HCPT - HUAWEI
IF cable must be up tilted
or have Waterproof curvein the entrance of
porthole
Cable Installation and endto end labeling
Porthole connection should be waterproofed
Right position for hole IF cable route
Proper installation for IF
cable and separation with
GND cable
8/19/2019 MW RTN Installation Standard v0 1
9/14
RTN 600 MW Installation Standard 9 HCPT - HUAWEI
IF cable labeling /
identifier
IF cable should have identifier / labeling on top near connector of
ODU and IDU
Outdoor IF Labeling Indoor IF Labeling
Outdoor labeling: Indoor labeling:
Labeling Format:
Label template :
For 1+1, use mark IF1 for main IF and IF2 for stand by IF
Font : Black
Background : White
Material : Print Label, Label flag, cable ties, IF cable label
IF 1 TO XXX (FE ID)
FAR END NAME
8/19/2019 MW RTN Installation Standard v0 1
10/14
RTN 600 MW Installation Standard 10 HCPT - HUAWEI
4. Indoor Equipment Fastness
Key Points Details Description
The installationposition of IDU
accords to the
engineering designdocument.
Outdoor Installation and IDU placement (on BTS 3012AE)
Outdoor Installation and IDU placement (on BTS 3900A)
Indoor Installation and IDU placement on 19” rack
8/19/2019 MW RTN Installation Standard v0 1
11/14
RTN 600 MW Installation Standard 11 HCPT - HUAWEI
IDU and DCPDB
labeling standard
Standard labeling and labeling format
IF Board LabelingLabeling Format:
Label template :
For 1+1, use mark IF1 for main IF and IF2 for stand by IF
Font : Black
Background : White
Material : Print Label,
Power Cable LabelingLabeling Format:
Label template :
Font : Black
Background : White
Material : Print Label, Flag label tie
Tributary Cable LabelingLabeling Format:
Label template :
Font : Black
Background : White
Material : Print Label, Flag label tie
Labeling on rectifier power cableLabeling Format:
Label template :
Font : Black
Background : White
Material : Print Label, Flag label tie
TO : FE ID , FE NAME
TX. xxxx MHz, RX. xxxx MHz
TO : POWER CABLE
TO : DDF
TO : FAR END ID
8/19/2019 MW RTN Installation Standard v0 1
12/14
RTN 600 MW Installation Standard 12 HCPT - HUAWEI
Labeling on DCPDBLabeling Format:
Label template :
Font : Black
Background : White
Material : Print Label
DDF Labeling
Standard
Standard labeling for outdoor DDF (sample)
Standard labeling for Indoor DDF (sample)
TO : FAR END ID
8/19/2019 MW RTN Installation Standard v0 1
13/14
RTN 600 MW Installation Standard 13 HCPT - HUAWEI
5. Cable distribution and routing
Key Points Details Description
Cable distribution andcable routing Cable routing standard for outdoor BTS.
Cable routing standard for indoor BTS (1).
8/19/2019 MW RTN Installation Standard v0 1
14/14
RTN 600 MW Installation Standard 14 HCPT - HUAWEI
Cable routing standard for indoor BTS (2).