21
97 Coverage chart - Campo de aplicaciones n ≈ 3450 rpm 500 120 140 100 80 60 40 U.S. g.p.m. 0 100 80 60 40 20 400 300 200 100 24 8 16 Imp. g.p.m. 150 200 100 50 0 50 70 60 40 30 20 10 0 0 0 32 0 MXH 2 MXH 4 MXH 8 MXH 16 H m /h l/min 3 Q m ft MXH 72.833/2 Horizontal multi-stage close coupled pumps in stainless steel Bombas multicelulares horizontales monobloc de acero inoxidable MXH MXH 2,4,8,16 2,4,8,16 60 Hz 60 Hz

MXH 2,4,8,16 60 HzSingle-piece barrel casing, with front suction port above pumps axis and radial delivery at top. Filling and draining plugs on the middle of the pump, accessible

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: MXH 2,4,8,16 60 HzSingle-piece barrel casing, with front suction port above pumps axis and radial delivery at top. Filling and draining plugs on the middle of the pump, accessible

97

Coverage chart - Campo de aplicaciones n ≈ 3450 rpm

500

120 140 100 80 60 40 U.S. g.p.m. 0

100 80 60 40 20

400 300 200 100 24 8 16

Imp. g.p.m.

150

200

100

50

0

50

70

60

40

30

20

10

0

0

0 32 0

MXH 2 MXH 4 MXH 8 MXH 16

H

m /h l/min

3

Q

m

ft

MXH

72.833/2

Horizontal multi-stage close coupled pumps in stainless steelBombas multicelulares horizontales monobloc de acero inoxidable

MXH MXH 2,4,8,162,4,8,16 60 Hz60 Hz

Page 2: MXH 2,4,8,16 60 HzSingle-piece barrel casing, with front suction port above pumps axis and radial delivery at top. Filling and draining plugs on the middle of the pump, accessible

98

ConstructionHorizontal multi-stage close coupled pumps in chrome-nickel stain-less steel.Compact and robust construction, without protruding flange and withsingle-piece lantern bracket and base.Single-piece barrel casing, with front suction port above pumps axisand radial delivery at top.Filling and draining plugs on the middle of the pump, accessible fromany side (like the terminal box).

Version with frequency converter (on request)

ApplicationsFor water supply.For clean liquids, without abrasives, which are non-aggressive forstainless steel (with suitable seal materials, on request).Universal pump, for domestic use, for civil and industrial applications,for garden use and irrigation.

Operating conditionsLiquid temperature from - 15 °C to + 110 °C.Ambient temperature up to 40 °C.Maximum permissible pressure in the pump casing: 8 bar.Continuous duty.

Motor2-pole induction motor, 60 Hz (n = 3450 rpm).MXH: three-phase 220/380 V, 220/440 V, up to 3 kW;

380/660 V, from 3,7 to 4 kW;MXHM: single-phase 110 V, 127 V, 220 V, 110/220 V.

with thermal protector up to 1.1 kW only 220V.Capacitor inside the terminal box.

Insulation class F. Protection IP 54.Motor suitable for operation with frequency converter from 1,8 kW.Classification scheme IE2 for three-phase motor from 0,75 kW.Constructed in accordance with EN 60034-1, EN 60034-30.

EN 60335-1, EN 60335-2-41.

Special features on request- Other voltages. - Protection IP 55.- Special mechanical seal- Seal rings in FPM.- Higher or lower liquid or ambient temperatures.- Motor suitable for operation with frequency converter up to 1,5 kW.

MaterialsComponent MaterialPump casing Cr-Ni steel 1.4301 EN 10088 (AISI 304)Stage casing Cr-Ni steel 1.4301 EN 10088 (AISI 304)Wear ring PTFEImpeller Cr-Ni steel 1.4301 EN 10088 (AISI 304)Casing cover Cr-Ni steel 1.4301 EN 10088 (AISI 304)Spacer sleeve Cr-Ni steel 1.4301 EN 10088 (AISI 304)Pump shaft Cr-Ni steel 1.4305 EN 10088 (AISI 303)Plug Cr-Ni steel 1.4305 EN 10088 (AISI 303)Mechanical seal Ceramic alumina, carbon, EPDMISO 3069 - KU (Other materials on request)

MXH MXH 2,4,8,162,4,8,16 60 Hz60 Hz

EjecuciónBombas multicelulares horizontales monobloc de acero inoxidable alcromo-níquel.Construcción compacta y robusta, sin brida sobresaliente y acopla-miento bomba motor único con pie soporte.Cuerpo bomba en una sola pieza, abierto por un solo lado (barrielcasing), con boca de aspiración frontal sobre el eje de la bomba y bocade impulsión radial en la parte superior.Tapones de cebado y vaciado en posiciones medias, accesibles desdecada lado (como la tapa de bornes).

Versión con variador de frecuencia (bajo demanda)

AplicacionesPara aprovisionamiento de agua.Para líquidos limpios, sin partes abrasivas, no agresivos para el aceroinoxidable (con adaptación, bajo demanda, de los materiales del sellomecánico).Bomba universal, para uso doméstico, para aplicaciones civiles e indu-striales, para jardinería e irrigación.

Límites de empleoTemperatura líquido de - 15 °C a + 110 °C.Temperatura ambiente hasta 40 °C.Presión máxima admitida en el cuerpo de la bomba: 8 bar.Servicio continuo.

MotorMotor a inducción 2 polos, 60 Hz (n = 3450 1/min).MXH: trifásico 220/380 V, 220/440 V, hasta 3 kW;

380/660 V, de 3,7 a 4 kW;MXHM: monofásico 110 V, 127 V, 220 V, 110/220 V.

con protector térmico hasta 1,1 kW sólo para 220V.Condensador incorporado en la caja de bornes.

Aislamiento clase F. Protección IP 54.Motor preparado al funcionamiento con convertidor de frecuencia de1,8 kW.Clase alta eficiencia IE2 para motor trifásico de 0,75 kW.Ejecución según: IEN 60034-1; EN 60034-30.

EN 60335-1, EN 60335-2-41.

Otras ejecuciones bajo demanda- Otras tensiones.- Protección IP 55.- Sello mecánico especial.- Anillos de cierre cuerpo bomba en FPM.- Para líquidos o ambientes con temperaturas más elevadas o más bajas.- Motor preparado al funcionamiento con convertidor de frecuencia

hasta 1,5 kW.

MaterialesComponentes MaterialesCuerpo bomba Acero al Cr-Ni 1.4301 EN 10088 (AISI 304)Cuerpo elemento Acero al Cr-Ni 1.4301 EN 10088 (AISI 304)Anillo de cierre rodete PTFERodete Acero al Cr-Ni 1.4301 EN 10088 (AISI 304)Tapa del cuerpo Acero al Cr-Ni 1.4301 EN 10088 (AISI 304)Manguito distanciador Acero al Cr-Ni 1.4301 EN 10088 (AISI 304)Eje bomba Acero al Cr-Ni 1.4305 EN 10088 (AISI 303)Tapón Acero al Cr-Ni 1.4305 EN 10088 (AISI 303)Sello mecánico Cerámica alúmina, carbón, EPDMsegún ISO 3069 - KU (Otros materiales bajo demanda)

Page 3: MXH 2,4,8,16 60 HzSingle-piece barrel casing, with front suction port above pumps axis and radial delivery at top. Filling and draining plugs on the middle of the pump, accessible

99

Pumps with frequency converter

The MXH EI pumps are available with power from 0,55 kW up to 4kW, the pumps are equipped with I-MAT installed on board whichallows to realize a variable-speed system extremely compact andefficient, ideal in applications of water supply and in the distribution ofhot and cold water. The pump is equipped with transducerssuitable for operation and is alreadyprogrammed at the factory.

Advantages- Energy saving- Compact design- Easy to use- Programmable to suit the system

requirements- Reliability

CostructionThe system comprises of:- Pump- Induction motor- I-MAT Frequency converter- Motor adapter for the motor mounting

of the frequency converter- Connection cable between frequency

converter and induction motor- Transducers

Main featuresRated motor power output from 0,55 kW to 4 kWControl range from 1750 to 3450 rpm (2-pole)Protection against dry runningProtection against operations with closed valve portsProtection against system leakagesProtection against overcurrent in the motorProtection agains overvoltage and undervoltage of the power supplyProtection against current unbalances between phases

Bomba a velocidad variable

La bomba MXH EI se encuentra disponible con potencias de 0,55 kW a 4kW y llevan incorporado un variador I-MAT que permite realizar un sistemade velocidad variable extremadamente compacto y eficiente, ideal paraaplicaciones de abastecimiento de agua y la distribución de agua fría y

caliente.Bomba eléctrica es suministrada con untransductor de presión idóneo para el modooperación que escoja el cliente y programadodirectamente desde fábrica

Ventajas- Ahorro de energía- Diseño compacto- Fácil de usar- Programable para las necesidades delsistema

- Fiabilidad

Construcción- El sistema está compuesto por:- Bomba- Motor de inducción- I-MAT variador de frecuencia- Adaptador del motor para el montaje delvariador de frecuencia

- Cable de conexión entre en variador y labomba eléctrica

- Transductores

Límites de utilizaciónPotencia nominal del motor desde 0,55 kW hasta 4 kWRango de control desde 1750 hasta 3450 rpm (2 polos)Protección contra el funcionamiento en secoProtección contra el funcionamiento con válvula cerradaProtección contra fugas del sistemaProtección contra sobrecorriente del motorProtección contra sobrevoltaje o bajovoltaje de la red de alimentaciónProtección contra el desequilibrio de fases

MXH EIMXH EI 60 Hz60 Hz

Constant pressure mode with pressure transducer

In this mode, the system maintains the preset pres-sure when the flow required by the installationchanges.

Proportional pressure mode with pressure transducer

In this mode the system changes the working pres-sure according to the required flow rate.

Constant flow mode with flow meter

In this mode the system maintains a constant flowrate value in a point of the installation according tothe required pressure.

Fixed speed mode with setting of the speed preferential rotation.

In this mode, by changing the working frequency,you may choose any operational curve includedwithin the working range.

Constant temperature modewith temperature transducerIn this mode the system keeps the temperatureconstant inside a system by changing the speed ofthe pump.

Modo presión constante con sensor de presión

En el modo de presión constante, el sistema mantie-ne la presión prefijada cuando cambia el caudal porlos cambios de la instalación.

Modo presión proporcional con sensor de presión

En el modo de presión proporcional, el sistema cam-bia la presión de trabajo de acuerdo al caudal reque-rido.

Modo caudal constante con medidor de caudal

En el modo caudal constante el sistema mantiene elcaudal constante en un punto de la instalación deacuerdo a la presión requerida.

Modo velocidad fija con el ajuste de la velocidad de rotación preferencial

En el modo velocidad fija, cambiando la frecuenciade trabajo, se puede escoger cualquier curva operati-va dentro del rango de trabajo de la bomba.

Modo temperatura constantecon sensor de temperaturaEn este modo el sistema mantiene la temperaturaconstante dentro de un sistema cambiando la veloci-dad de la bomba.

Operating modes Modos de operaciónH

Q

H

Q

H

Q

H

max

min

+-

+-

+ -

+-

Page 4: MXH 2,4,8,16 60 HzSingle-piece barrel casing, with front suction port above pumps axis and radial delivery at top. Filling and draining plugs on the middle of the pump, accessible

100

Performance - Prestaciones n ≈ 3450 rpm

16

33

49,5

66

15,2

31

47

63

14,5

30

45,5

60,5

13,7

28,5

43,5

58

13

27

41

55

12

25,5

38,5

51,5

10,7

23,5

35,5

47,5

9,6

21

32

43

8,5

19

28,5

38,5

7

16

24

33

MXH 201-60E

MXH 202-60/A

MXH 203-60/A

MXH 204-60/B

MXHM 201-60E

MXHM 202-60/A

MXHM 203-60/A

MXHM 204-60

kW

0,25

0,55

0,75

1,1

HP

0,34

0,75

1

1,5

Qm /h

l/min

H m

3

3 ~ 1 ~ P2

58,341,6

0

0

1

16,6

1,5

25

2

33,3

2,5 3

50

3,5 4

66,6

4,5

75

5

83,3

16

32,5

49

65,5

14,5

29,5

45,5

60

14

29

44,5

59

13,5

28,5

43,5

57,5

13

27,5

42

56

11,7

26

39,5

52,5

10,2

23,5

36

48,5

8,5

20,5

31,5

42,5

6,5

17

26,5

35,5

4

12,5

20

26

MXH 401-60E

MXH 402-60/A

MXH 403-60/B

MXH 404-60

MXHM 401-60E

MXHM 402-60/A

MXHM 403-60

MXHM 404-60

kW

0,33

0,75

1,1

1,5

HP

0,45

1

1,5

2

Qm /h

l/min

H m

3

3 ~ 1 ~ P2

10066,6

0

0

2,5

41,6

3

50

3,5

58,3

4 5

83,3

6 7

116

8

133

9

150

16,5

33,5

51

69

14,4

30,4

45

60

14

29

42,5

57,5

12,3

26,5

38,5

53

11,3

25

36,5

50,5

10

23

33,5

47

8,8

20,5

30,5

43

7,3

18

26,5

38

5,6

15

22,5

31

MXH 801-60/A

MXH 802-60

MXH 803-60/A

MXH 804-60/A

MXHM 801-60/A

MXHM 802-60

MXHM 803-60

kW

0,55

1,5

1,8

2,2

HP

0,75

2

2,5

3

Qm /h

l/min

H m

3

3 ~ 1 ~ P2

200166

0

0

6,5

108

15,6

31,3

47

63

5

83,3

8

133

10 11

183

12 13

216

14

233

15

250

35

52,5

70

33

49,5

66

31,8

47,7

63,5

30,2

45,3

60,4

28,3

42,5

56,5

26

39

52

23,5

35,2

47

20

30

40

15,8

23,7

31,5

MXH 1602-60/A

MXH 1603-60/A

MXH 1604-60/A

kW

2,2

3

4

HP

3

4

5,5

Qm /h

l/min

H m

3

3 ~ P2

350250

0

0

6

100

9

150

12

200

15 18

300

21 24

400

27

450

Test results with clean cold water, without gas content.Resultados de las pruebas con agua fría y limpia, sin gas.

MXH MXH 2,4,8,162,4,8,16 60 Hz60 Hz

Rated currents - Intensidades nominales

P2 Rated motor power output.Potencia nominal del motor.

IA/IN D.O.L. starting current / Rated currentIntensidad de arranque / Intensidad nominal

0,250,330,550,751,11,51,8

kW

0,340,450,75

11,52

2,5

2,32,85

6,28,5

10,613,5

HP IN A220V

44,88,7

10,714,718,4

-

IN A127V

single-phase - monofásico1~

4,65,610

12,417--

IN A110V

--

9.2/4.712.5/6.4

---

IN A110/220V

1,82,73,12,93

3,84,5

IA/IN

0,250,330,550,751,11,51,82,234

kW

0,340,450,75

11,52

2,534

5,5

1,7/12/1,2

3,3/1,94,5/2,65,7/3,37,4/4,39/5,2

11,1/6,413,4/7,7

HP IN A220/380V

three-phase - trifásico3~

---------

11,2/6,5

IN A380/660V

1,8/1,12,2/1,33,5/2,04,7/2,76,0/3,57,8/4,59,4/5,511,6/6,714,0/8,1

IN A220/440V

4,74

4,36,85,56,66

7,38,47,8

IA/IN

P2 Rated motor power output.Potencia nominal del motor.

+ 0,5 m security margin on NPSH-value is necessary.

Para el valor del NPSH se recomienda un margen de seguridad de + 0,5 m.

Tolerances according to UNI EN ISO 9906:2012.Tolerancias según UNI EN ISO 9906:2012.

Page 5: MXH 2,4,8,16 60 HzSingle-piece barrel casing, with front suction port above pumps axis and radial delivery at top. Filling and draining plugs on the middle of the pump, accessible

101

Dimensions and weights - Dimensiones y pesos

TYPETIPO

TYPETIPO

● Standard dimensions - Dimensiones estándar ❏ Cannot constructed - Non fatibles

● Standard dimensions - Dimensiones estándar ❏ Cannot constructed - Non fatibles

331

357

357

331

357

381

MXH 201-60E - MXHM 201-60E

MXH 202-60/A - MXHM 202-60/A

MXH 203-60/A - MXHM 203-60/A

MXH 401-60E - MXHM 401-60E

MXH 402-60/A - MXHM 402-60/A

MXH 801-60/A - MXHM 801-60/A

94

94

94

94

94

118

fM a

mm

MXH MXHM

6,6

9,1

10,5

6,6

10

9,7

6,7

10,1

11,5

6,7

11

10,5

kg

176

192

192

176

192

192

H

98,5

112

112

98,5

112

112

w1

-

197

197

-

197

197

H*

116

116

127V

116

116

110V

220V

116

131

131

116

110/220V

ISO 228

DN2DN1

G 1

G 1

G 1

G 1

G 1

G 1

G 1 1/4

G 1 1/4

G 1 1/4

G 1 1/4

G 1 1/4

G 1 1/2

ISO 228

DN2DN1

453

453

453

453

493

522

504

575

612

MXH 204-60/B - MXHM 204-60

MXH 403-60/B - MXHM 403-60

MXH 404-60 - MXHM 404-60

MXH 802-60 - MXHM 802-60

MXH 803-60/A - MXHM 803-60

MXH 804-60/A

MXH 1602-60/A

MXH 1603-60/A

MXH 1604-60/A

118

118

118

118

118

148

128

128

166

fM a

mm

G 1

G 1

G 1

G 1

G 1

G 1

G 1 1/2

G 1 1/2

G 1 1/2

G 1 1/4

G 1 1/4

G 1 1/4

G 1 1/2

G 1 1/2

G 1 1/2

G 2

G 2

G 2

MXH MXHM

-

-

18,5

18

18,3

19,8

18,3

30

31

17,7

17,2

19,2

18,9

19,3

-

-

kg

127

127

127

127

127

127

117

132

132

h1

57

57

57

57

57

57

70

70

70

88

88

88

88

88

88

101

113

113

h2

10

10

10

10

10

10

10

12

12

m3

31

31

31

31

31

31

31

45

45

m1w

210

210

210

210

210

210

210

235

235

H

167

167

167

167

167

167

167

232

232

w1

215

215

215

215

215

-

-

-

-

H*

131

131

131

131

-

-

-

-

127V

131

131

-

-

-

-

110V

131

-

-

-

-

220V

-

-

-

-

110/220V

AR

AS

88

28

4.93.209

8

w1

DN

1(1)

fM

DN 2

a

10

30

112

146

57

H

9

160

127

H*

(2)

AR

DN 2

a

fM

DN

1

w1

m1

m3w

3.93.020/1

10,5 10

112

h1h2

H

146

160

30,5

H*

AS

(1)

(2)

(1) Filling (2) Draining Cebado Vaciado

MXH MXH 2,4,8,162,4,8,16 60 Hz60 Hz

Page 6: MXH 2,4,8,16 60 HzSingle-piece barrel casing, with front suction port above pumps axis and radial delivery at top. Filling and draining plugs on the middle of the pump, accessible

102

Characteristic curves - Curvas Características n ≈ 3450 rpm

4

2

10

50

30

20

10

70 50 30 80 60 40 20

Imp. g.p.m. 15 10 5

150

200

100

50

0

4 3 2 1

4 3 2 1

50

60

70

40

30

20

10

0 0 5 0

0

0

0 5 0

20 15 10 5 U.S. g.p.m. 0

9

9

7

7

5

5 3

3

60

40

30

20

140 100 60 160 120 80 40

Imp. g.p.m. 30 20 10

150

200

100

50

0

8 6 4 2

8 6 4 2

50

70

60

40

30

20

10

10

0

2

4

0 10 0

0

0

0 10 0

40 30 20 10 U.S. g.p.m. 0

250

4

5

2

40

70

60 50 40 30 20 U.S. g.p.m. 0

15

5

50 40 30 20

200 150 100 50

10

10

5

5

15

Imp. g.p.m.

50

30

150

200

100

50

0

50

70

60

40

30

20

10

10 3

1

0

0

0

0 15 0

72.580/1 72.581/1

72.582/1

MXH 202-60

MXH 201-60

MXH 203-60

MXH 204-60

MXH 403-60

MXH 404-60

MXH 402-60

MXH 401-60

MXH 803-60

MXH 804-60

MXH 802-60

MXH 801-60

H

m /h l/min

3

Q

m /h 3 Q

m

ft

η %

NPSH m

ft

H

m /h l/min

3

Q

m /h 3 Q

m

ft

η %

NPSH m

ft

H

m /h l/min

3

Q

m /h 3 Q

m

ft

η %

NPSH m

ft

MXH 2

MXH 8

MXH 4

500

6

8

2

40

70

120 1 00 8 0 6 0 4 0 U.S. g.p.m. 0

15

5

100 8 0 6 0 4 0

400 3 00 2 00 1 00

20

20

10

10

30

Imp. g.p.m.

50

30

150

200

100

50

0

50

70

60

40

30

20

10

10 4

0

0

0

0

0 30 0

72.582/2

MXH 1602-60

MXH 1603-60

MXH 1604-60

H

m /h l/min

3

Q

m /h 3 Q

m

ft

η %

NPSH ft

MXH 16

MXH MXH 2,4,8,162,4,8,16 60 Hz60 Hz

Page 7: MXH 2,4,8,16 60 HzSingle-piece barrel casing, with front suction port above pumps axis and radial delivery at top. Filling and draining plugs on the middle of the pump, accessible

103

Features - Características constructivas

Extra safetyagainst running dry, with the suction port above pump axis.

ReliableAll hydraulic parts in contact with the pumped liquid are ofstainless steel. For liquids from -15 °C to 110 °C.

RobustSingle-piece, thick barrel casing.

CompactSingle-piece lantern bracket and base.Without protruding flange.

Greater protectionAgainst leakage, with the pump casing cover separated fromthe motor shield. Possibility of inspecting the seal through the side aperturesbetween the two walls.Greater protection against water entering the motor from outsi-de provided by an extension of the pump casing around thelantern bracket.

3.93.001

MXH MXH 2,4,8,162,4,8,16 60 Hz60 Hz

Más seguridadContra el funcionamiento en seco, con la boca de aspiraciónsobre el eje de la bomba.

FiableTodas las partes hidráulicas en contacto con el líquido son deacero inoxidable. Para líquidos de -15 °C a +110 °C.

RobustaCuerpo bomba de una sola pieza de grueso espesor, abiertopor un solo lado.

CompactaAcoplamiento bomba motor y base soporte de una sola pieza.Sin brida sobresaliente.

Mayor protecciónContra las pérdidas del cierre, con la tapa de la bomba sepa-rada de la tapa del motor. Posibilidad de inspección del sellomecánico a través de la abertura lateral entre las dos paredes.Mayor protección contra la penetración del agua en el motor,obtenida por medio del cuerpo bomba prolongad o sobre elacoplamiento.

Page 8: MXH 2,4,8,16 60 HzSingle-piece barrel casing, with front suction port above pumps axis and radial delivery at top. Filling and draining plugs on the middle of the pump, accessible

104

MXHL MXHL 60 Hz 60 Hz AISI 316AISI 316

604020U.S. g.p.m.0

604020

3002001008 124 1610 146 18

Imp. g.p.m.

150

200

100

50

0

50

70

60

40

30

20

10

0

0

00

MXHL 2 MXHL 4 MXHL 8

H

m /hl/min

3

Q

m

ft

MXHL

72.833/2

Coverage chart - Campo de aplicaciones n ≈ 3450 rpm

Horizontal multi-stage close coupled pumps in stainless steelBombas multicelulares horizontales monobloc de acero inoxidable

Page 9: MXH 2,4,8,16 60 HzSingle-piece barrel casing, with front suction port above pumps axis and radial delivery at top. Filling and draining plugs on the middle of the pump, accessible

105

MXHL MXHL 60 Hz 60 Hz AISI 316AISI 316

ConstructionHorizontal multi-stage close coupled pumps in chrome-nickel-molyb-denum stainless steel AISI 316L.Compact and robust construction, without protruding flange and withsingle-piece lantern bracket and base.Single-piece barrel casing, with front suction port above pumps axisand radial delivery at top.Filling and draining plugs on the middle of the pump, accessible fromany side (like the terminal box).

Version with frequency converter (on request)

ApplicationsFor water supply.For clean liquids, without abrasives, which are non-aggressive forstainless steel (with suitable seal materials, on request).Universal pump, for domestic use, for civil and industrial applications,for garden use and irrigation.

Operating conditionsLiquid temperature from - 15 °C to + 110 °C.Ambient temperature up to 40 °C.Maximum permissible pressure in the pump casing: 8 bar.Continuous duty.

Motor2-pole induction motor, 60 Hz (n = 3450 rpm).MXHL: three-phase 220/380 V, 220/440 V.MXHLM: single-phase 110 V, 127 V, 220 V, 110/220 V.

with thermal protector up to 1.1 kW only 220V.Capacitor inside the terminal box.

Insulation class F. Protection IP 54.Motor suitable for operation with frequency converter from 1,8 kW.Classification scheme IE2 for three-phase motor from 0,75 kW.Constructed in accordance with EN 60034-1, EN 60034-30.

EN 60335-1, EN 60335-2-41.

Special features on request- Other voltages. - Protection IP 55.- Special mechanical seal- Seal rings in FPM.- Higher or lower liquid or ambient temperatures.- Motor suitable for operation with frequency converter up to 1,5 kW.

MaterialsComponent MaterialPump casing Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L)Stage casing Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L)Wear ring PTFEImpeller Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L)Casing cover Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L)Spacer sleeve Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L)Pump shaft Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L)Plug Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L)Mechanical seal Ceramic alumina, carbon, EPDMISO 3069 - KU (Other materials on request)

EjecuciónBombas multicelulares horizontales monobloc de acero inoxidable alcromo-níquel-molibdeno AISI 316LConstrucción compacta y robusta, sin brida sobresaliente y acopla-miento bomba motor único con pie soporte.Cuerpo bomba en una sola pieza, abierto por un solo lado (barrielcasing), con boca de aspiración frontal sobre el eje de la bomba y bocade impulsión radial en la parte superior.Tapones de cebado y vaciado en posiciones medias, accesibles desdecada lado (como la tapa de bornes).Versión variador de frecuencia (bajo demanda)

AplicacionesPara aprovisionamiento de agua.Para líquidos limpios, sin partes abrasivas, no agresivos para el aceroinoxidable (con adaptación, bajo demanda, de los materiales del sellomecánico).Bomba universal, para uso doméstico, para aplicaciones civiles e indu-striales, para jardinería e irrigación.

Límites de empleoTemperatura líquido de - 15 °C a + 110 °C.Temperatura ambiente hasta 40 °C.Presión máxima admitida en el cuerpo de la bomba: 8 bar.Servicio continuo.

MotorMotor a inducción 2 polos, 60 Hz (n = 3450 1/min).MXHL: trifásico 220/380 V, 220/440 V.MXHLM: monofásico 110 V, 127 V, 220 V, 110/220 V.

con protector térmico hasta 1,1 kW sólo para 220V.Condensador incorporado en la caja de bornes.

Aislamiento clase F. Protección IP 54.Motor preparado al funcionamiento con convertidor de frecuencia de1,8 kW.Clase alta eficiencia IE2 para motor trifásico de 0,75 kW.Ejecución según: IEN 60034-1; EN 60034-30.

EN 60335-1, EN 60335-2-41.

Otras ejecuciones bajo demandaOtras tensiones.Protección IP 55.Sello mecánico especial.Anillos de cierre cuerpo bomba en FPM.Para líquidos o ambientes con temperaturas más elevadas o más bajas.Motor preparado al funcionamiento con convertidor de frecuencia hasta1,5 kW.

MaterialesComponentes MaterialesCuerpo bomba Acero al Cr-Ni-Mo 1.4404 EN 10088 (AISI 316L)Cuerpo elemento Acero al Cr-Ni-Mo 1.4404 EN 10088 (AISI 316L)Anillo de cierre rodete PTFERodete Acero al Cr-Ni-Mo 1.4404 EN 10088 (AISI 316L)Tapa del cuerpo Acero al Cr-Ni-Mo 1.4404 EN 10088 (AISI 316L)Manguito distanciador Acero al Cr-Ni-Mo 1.4404 EN 10088 (AISI 316L)Eje bomba Acero al Cr-Ni-Mo 1.4404 EN 10088 (AISI 316L)Tapón Acero al Cr-Ni-Mo 1.4404 EN 10088 (AISI 316L)Sello mecánico Cerámica alúmina, carbón, EPDMsegún ISO 3069 - KU (Otros materiales bajo demanda)

Page 10: MXH 2,4,8,16 60 HzSingle-piece barrel casing, with front suction port above pumps axis and radial delivery at top. Filling and draining plugs on the middle of the pump, accessible

MXHL MXHL 60 Hz 60 Hz AISI 316AISI 316

106

Pumps with frequency converter

The MXHL EI pumps are available with power from 0,55 kW up to 2,2kW, the pumps are equipped with I-MAT installed on board whichallows to realize a variable-speed system extremely compact andefficient, ideal in applications of water supply and in the distribution ofhot and cold water. The pump is equipped with transducerssuitable for operation and is alreadyprogrammed at the factory.

Advantages- Energy saving- Compact design- Easy to use- Programmable to suit the system

requirements- Reliability

CostructionThe system comprises of:- Pump- Induction motor- I-MAT Frequency converter- Motor adapter for the motor mounting

of the frequency converter- Connection cable between frequency

converter and induction motor- Transducers

Main featuresRated motor power output from 0,55 kW to 2,2 kWControl range from 1750 to 3450 rpm (2-pole)Protection against dry runningProtection against operations with closed valve portsProtection against system leakagesProtection against overcurrent in the motorProtection agains overvoltage and undervoltage of the power supplyProtection against current unbalances between phases

Bomba a velocidad variable

La bomba MXHL EI se encuentra disponible con potencias de 0,55 kW a2,2 kW y llevan incorporado un variador I-MAT que permite realizar unsistema de velocidad variable extremadamente compacto y eficiente, idealpara aplicaciones de abastecimiento de agua y la distribución de agua fría

y caliente.Bomba eléctrica es suministrada con untransductor de presión idóneo para el modooperación que escoja el cliente y programadodirectamente desde fábrica

Ventajas- Ahorro de energía- Diseño compacto- Fácil de usar- Programable para las necesidades delsistema

- Fiabilidad

Construcción- El sistema está compuesto por:- Bomba- Motor de inducción- I-MAT variador de frecuencia- Adaptador del motor para el montaje delvariador de frecuencia

- Cable de conexión entre en variador y labomba eléctrica

- Transductores

Límites de utilizaciónPotencia nominal del motor desde 0,55 kW hasta 2,2 kWRango de control desde 1750 hasta 3450 rpm (2 polos)Protección contra el funcionamiento en secoProtección contra el funcionamiento con válvula cerradaProtección contra fugas del sistemaProtección contra sobrecorriente del motorProtección contra sobrevoltaje o bajovoltaje de la red de alimentaciónProtección contra el desequilibrio de fases

Constant pressure mode with pressure transducer

In this mode, the system maintains the preset pres-sure when the flow required by the installationchanges.

Proportional pressure mode with pressure transducer

In this mode the system changes the working pres-sure according to the required flow rate.

Constant flow mode with flow meter

In this mode the system maintains a constant flowrate value in a point of the installation according tothe required pressure.

Fixed speed mode with setting of the speed preferential rotation.

In this mode, by changing the working frequency,you may choose any operational curve includedwithin the working range.

Constant temperature modewith temperature transducerIn this mode the system keeps the temperatureconstant inside a system by changing the speed ofthe pump.

Modo presión constante con sensor de presión

En el modo de presión constante, el sistema mantie-ne la presión prefijada cuando cambia el caudal porlos cambios de la instalación.

Modo presión proporcional con sensor de presión

En el modo de presión proporcional, el sistema cam-bia la presión de trabajo de acuerdo al caudal reque-rido.

Modo caudal constante con medidor de caudal

En el modo caudal constante el sistema mantiene elcaudal constante en un punto de la instalación deacuerdo a la presión requerida.

Modo velocidad fija con el ajuste de la velocidad de rotación preferencial

En el modo velocidad fija, cambiando la frecuenciade trabajo, se puede escoger cualquier curva operati-va dentro del rango de trabajo de la bomba.

Modo temperatura constantecon sensor de temperaturaEn este modo el sistema mantiene la temperaturaconstante dentro de un sistema cambiando la veloci-dad de la bomba.

Operating modes Modos de operaciónH

Q

H

Q

H

Q

H

max

min

+-

+-

+ -

+-

Page 11: MXH 2,4,8,16 60 HzSingle-piece barrel casing, with front suction port above pumps axis and radial delivery at top. Filling and draining plugs on the middle of the pump, accessible

107

MXHL MXHL 60 Hz 60 Hz AISI 316AISI 316

Performance - Prestaciones n ≈ 3450 rpm

16

33

49,5

66

15,2

31

47

63

14,5

30

45,5

60,5

13,7

28,5

43,5

58

13

27

41

55

12

25,5

38,5

51,5

10,7

23,5

35,5

47,5

9,6

21

32

43

8,5

19

28,5

38,5

7

16

24

33

MXHL 201-60E

MXHL 202-60/A

MXHL 203-60/A

MXHL 204-60/B

MXHLM 201-60E

MXHLM 202-60/A

MXHLM 203-60/A

MXHLM 204-60

kW

0,25

0,55

0,75

1,1

HP

0,34

0,75

1

1,5

Qm /h

l/min

H m

3

3 ~ 1 ~ P2

58,341,6

0

0

1

16,6

1,5

25

2

33,3

2,5 3

50

3,5 4

66,6

4,5

75

5

83,3

16

32,5

49

65,5

14,5

29,5

45,5

60

14

29

44,5

59

13,5

28,5

43,5

57,5

13

27,5

42

56

11,7

26

39,5

52,5

10,2

23,5

36

48,5

8,5

20,5

31,5

42,5

6,5

17

26,5

35,5

4

12,5

20

26

MXHL 401-60E

MXHL 402-60/A

MXHL 403-60/B

MXHL 404-60

MXHLM 401-60E

MXHLM 402-60/A

MXHLM 403-60

MXHLM 404-60

kW

0,33

0,75

1,1

1,5

HP

0,45

1

1,5

2

Qm /h

l/min

H m

3

3 ~ 1 ~ P2

10066,6

0

0

2,5

41,6

3

50

3,5

58,3

4 5

83,3

6 7

116

8

133

9

150

16,5

33,5

51

69

14,4

30,4

45

60

14

29

42,5

57,5

12,3

26,5

38,5

53

11,3

25

36,5

50,5

10

23

33,5

47

8,8

20,5

30,5

43

7,3

18

26,5

38

5,6

15

22,5

31

MXHL 801-60/A

MXHL 802-60

MXHL 803-60/A

MXHL 804-60/A

MXHLM 801-60/A

MXHLM 802-60

MXHLM 803-60

kW

0,55

1,5

1,8

2,2

HP

0,75

2

2,5

3

Qm /h

l/min

H m

3

3 ~ 1 ~ P2

200166

0

0

6,5

108

15,6

31,3

47

63

5

83,3

8

133

10 11

183

12 13

216

14

233

15

250

Test results with clean cold water, without gas content.Resultados de las pruebas con agua fría y limpia, sin gas.

Rated currents - Intensidades nominales

P2 Rated motor power output.Potencia nominal del motor.

IA/IN D.O.L. starting current / Rated currentIntensidad de arranque / Intensidad nominal

0,250,330,550,751,11,51,8

kW

0,340,450,75

11,52

2,5

2,32,85

6,28,5

10,613,5

HP IN A220V

44,88,7

10,714,718,4

-

IN A127V

single-phase - monofásico1~

4,65,610

12,417--

IN A110V

--

9.2/4.712.5/6.4

---

IN A110/220V

1,82,73,12,93

3,84,5

IA/IN

0,250,330,550,751,11,51,82,2

kW

0,340,450,75

11,52

2,53

1,7/12/1,2

3,3/1,94,5/2,65,7/3,37,4/4,39/5,2

11,1/6,4

HP IN A220/380V

three-phase - trifásico3~

1,8/1,12,2/1,33,5/2,04,7/2,76,0/3,57,8/4,59,4/5,511,6/6,7

IN A220/440V

4,74

4,36,85,56,66

7,3

IA/IN

P2 Rated motor power output.Potencia nominal del motor.

+ 0,5 m security margin on NPSH-value is necessary.

Para el valor del NPSH se recomienda un margen de seguridad de + 0,5 m.

Tolerances according to UNI EN ISO 9906:2012.Tolerancias según UNI EN ISO 9906:2012.

Page 12: MXH 2,4,8,16 60 HzSingle-piece barrel casing, with front suction port above pumps axis and radial delivery at top. Filling and draining plugs on the middle of the pump, accessible

108

MXHL MXHL 60 Hz 60 Hz AISI 316AISI 316

Dimensions and weights - Dimensiones y pesos

TYPETIPO

TYPETIPO

● Standard dimensions - Dimensiones estándar ❏ Cannot constructed - Non fatibles

● Standard dimensions - Dimensiones estándar ❏ Cannot constructed - Non fatibles

331

357

357

331

357

381

MXHL 201-60E - MXHLM 201-60E

MXHL 202-60/A - MXHLM 202-60/A

MXHL 203-60/A - MXHLM 203-60/A

MXHL 401-60E - MXHLM 401-60E

MXHL 402-60/A - MXHLM 402-60/A

MXHL 801-60/A - MXHLM 801-60/A

94

94

94

94

94

118

fM a

mm

MXH MXHM

6,6

9,1

10,5

6,6

10

9,7

6,7

10,1

11,5

6,7

11

10,5

kg

176

192

192

176

192

192

H

98,5

112

112

98,5

112

112

w1

181

197

197

181

197

197

H*

116

116

127V

116

116

110V

220V

116

131

131

116

110/220V

ISO 228

DN2DN1

G 1

G 1

G 1

G 1

G 1

G 1

G 1 1/4

G 1 1/4

G 1 1/4

G 1 1/4

G 1 1/4

G 1 1/2

ISO 228

DN2DN1

453

453

453

453

493

522

MXHL 204-60/B - MXHLM 204-60

MXHL 403-60/B - MXHLM 403-60

MXHL 404-60 - MXHLM 404-60

MXHL 802-60 - MXHLM 802-60

MXHL 803-60/A - MXHLM 803-60

MXHL 804-60/A

118

118

118

118

118

148

fM a

mm

G 1

G 1

G 1

G 1

G 1

G 1

G 1 1/4

G 1 1/4

G 1 1/4

G 1 1/2

G 1 1/2

G 1 1/2

MXH MXHM

-

-

18,5

18

18,3

19,8

17,7

17,2

19,2

18,9

19,3

-

kg

127

127

127

127

127

127

h1

57

57

57

57

57

57

88

88

88

88

88

88

h2w

210

210

210

210

210

210

H

167

167

167

167

167

167

w1

215

215

215

215

215

-

H*

131

131

131

131

-

127V

131

131

-

110V

131

-

220V

-

110/220V

AR

AS

DN 2

a

fM

DN

1

w1

31

10w

3.93.020/1

10,5 10

112

h1h2

H

146

160

30,5

H*

AS

(1)

(2)

88

28

4.93.209

8

w1

DN

1(1)

fM

DN 2

a

10

30

112

146

57

H

9

160

127

H*

(2)

AR

(1) Filling (2) Draining Cebado Vaciado

Page 13: MXH 2,4,8,16 60 HzSingle-piece barrel casing, with front suction port above pumps axis and radial delivery at top. Filling and draining plugs on the middle of the pump, accessible

109

Characteristic curves - Curvas Características n ≈ 3450 rpm

4

2

10

50

30

20

10

70 50 30 80 60 40 20

Imp. g.p.m. 15 10 5

150

200

100

50

0

4 3 2 1

4 3 2 1

50

60

70

40

30

20

10

0 0 5 0

0

0

0 5 0

20 15 10 5 U.S. g.p.m. 0

9

9

7

7

5

5 3

3

60

40

30

20

140 100 60 160 120 80 40

Imp. g.p.m. 30 20 10

150

200

100

50

0

8 6 4 2

8 6 4 2

50

70

60

40

30

20

10

10

0

2

4

0 10 0

0

0

0 10 0

40 30 20 10 U.S. g.p.m. 0

250

4

5

2

40

70

60 50 40 30 20 U.S. g.p.m. 0

15

5

50 40 30 20

200 150 100 50

10

10

5

5

15

Imp. g.p.m.

50

30

150

200

100

50

0

50

70

60

40

30

20

10

10 3

1

0

0

0

0 15 0

72.580/1 72.581/1

72.582/1

MXHL 202-60

MXHL 201-60

MXHL 203-60

MXHL 204-60

MXHL 403-60

MXHL 404-60

MXHL 402-60

MXHL 401-60

MXHL 803-60

MXHL 804-60

MXHL 802-60

MXHL 801-60

H

m /h l/min

3

Q

m /h 3 Q

m

ft

η %

NPSH m

ft

H

m /h l/min

3

Q

m /h 3 Q

m

ft

η %

NPSH m

ft

H

m /h l/min

3

Q

m /h 3 Q

m

ft

η %

NPSH m

ft

MXHL 2

MXHL 8

MXHL 4

MXHL MXHL 60 Hz 60 Hz AISI 316AISI 316

Page 14: MXH 2,4,8,16 60 HzSingle-piece barrel casing, with front suction port above pumps axis and radial delivery at top. Filling and draining plugs on the middle of the pump, accessible

110

Features - Características constructivas

MXHL MXHL 60 Hz 60 Hz AISI 316AISI 316

Extra safetyagainst running dry, with the suction port above pump axis.

ReliableAll hydraulic parts in contact with the pumped liquid are ofstainless steel. For liquids from -15 °C to 110 °C.

RobustSingle-piece, thick barrel casing.

CompactSingle-piece lantern bracket and base.Without protruding flange.

Greater protectionAgainst leakage, with the pump casing cover separated fromthe motor shield. Possibility of inspecting the seal through the side aperturesbetween the two walls.Greater protection against water entering the motor from outsi-de provided by an extension of the pump casing around thelantern bracket.

3.93.001

Más seguridadContra el funcionamiento en seco, con la boca de aspiraciónsobre el eje de la bomba.

FiableTodas las partes hidráulicas en contacto con el líquido son deacero inoxidable. Para líquidos de -15 °C a +110 °C.

RobustaCuerpo bomba de una sola pieza de grueso espesor, abiertopor un solo lado.

CompactaAcoplamiento bomba motor y base soporte de una sola pieza.Sin brida sobresaliente.

Mayor protecciónContra las pérdidas del cierre, con la tapa de la bomba sepa-rada de la tapa del motor. Posibilidad de inspección del sellomecánico a través de la abertura lateral entre las dos paredes.Mayor protección contra la penetración del agua en el motor,obtenida por medio del cuerpo bomba prolongad o sobre elacoplamiento.

Page 15: MXH 2,4,8,16 60 HzSingle-piece barrel casing, with front suction port above pumps axis and radial delivery at top. Filling and draining plugs on the middle of the pump, accessible

111

MXH MXH 20,32,4820,32,48 60 Hz60 Hz

Coverage chart - Campo de aplicaciones n ≈ 3450 rpm

ft

m

m /hl/min

H

Q3

1000

200 250

5010 30 60 70800600400200

Imp. g.p.m. 15010050

200

100

300

04020

60

70

80

90

100

110

120

40

20

30

10

0

200 250 300U.S. g.p.m. 150100500

0

00

MXH 48

MXH

MXH 32MXH 20

72.978/05

Horizontal multi-stage close coupled pumps in stainless steelBombas multicelulares horizontales monobloc de acero inoxidable

Page 16: MXH 2,4,8,16 60 HzSingle-piece barrel casing, with front suction port above pumps axis and radial delivery at top. Filling and draining plugs on the middle of the pump, accessible

112

MaterialsComponent MaterialPump casing Cr-Ni steel 1.4301 EN 10088 (AISI 304)Stage casing Cr-Ni steel 1.4301 EN 10088 (AISI 304)Wear ring PTFEImpeller Cr-Ni steel 1.4301 EN 10088 (AISI 304)Casing cover Cr-Ni steel 1.4301 EN 10088 (AISI 304)Spacer sleeve Cr-Ni steel 1.4301 EN 10088 (AISI 304)Pump shaft Cr-Ni steel 1.4305 EN 10088 (AISI 303)Plug Cr-Ni steel 1.4305 EN 10088 (AISI 303)Mechanical seal Ceramic alumina, carbon, EPDMISO 3069 - KU (Other materials on request)

MaterialesComponentes MaterialesCuerpo bomba Acero al Cr-Ni 1.4301 EN 10088 (AISI 304)Cuerpo elemento Acero al Cr-Ni 1.4301 EN 10088 (AISI 304)Anillo de cierre rodete PTFERodete Acero al Cr-Ni 1.4301 EN 10088 (AISI 304)Tapa del cuerpo Acero al Cr-Ni 1.4301 EN 10088 (AISI 304)Manguito distanciador Acero al Cr-Ni 1.4301 EN 10088 (AISI 304)Eje bomba Acero al Cr-Ni 1.4305 EN 10088 (AISI 303)Tapón Acero al Cr-Ni 1.4305 EN 10088 (AISI 303)Sello mecánico Cerámica alúmina, carbón, EPDMISO 3069 - KU (Otros materiales bajo demanda)

ConstructionHorizontal multi-stage close coupled pumps in chrome-nickel stain-less steel.Compact and robust construction,with compact lantern bracket andmotor with feet.Single-piece barrel casing, with front suction port above pumps axisand radial delivery at top. Filling and draining plugs on the middle ofthe pump, accessible from any side (like the terminal box).Version with frequency converter (on request)

ApplicationsFor water supply.For clean liquids, without abrasives, which are non-aggressive forstainless steel (with suitable seal materials, on request).Universal pump, for civil and industrial applications, for garden useand irrigation.

Operating conditionsLiquid temperature from - 15 °C to + 110 °C.Ambient temperature up to 40 °C.Maximum permissible pressure in the pump casing: 10 bar.Continuous duty.

Motor2-pole induction motor, 60 Hz (n = 3450 rpm).MXH: three-phase 220/380 V, 220/440 V, up to 3 kW;

380/660 V, from 4 to 15 kW;Insulation class F.Protection IP 54.Motor suitable for operation with frequency converter.Classification scheme IE2 for three-phase motors from 0,75 kW to5,5 kW, IE3 from 7,5 kW.Constructed in accordance with: EN 60034-1;

EN 60034-30.

Special features on request- Pump with Victaulic ports (MXH-V) for 32, 48.- Pump with flanged ports (MXH-F).- Other voltages.- Protection IP 55.- Special mechanical seal- Seal rings in FPM.- Higher or lower ambient temperatures.

MXH MXH 20,32,4820,32,48 60 Hz60 Hz

EjecuciónBombas multicelulares horizontales monobloc de acero inoxidable alcromo-níquel.Construccion compacta y muy robusta, con acoplamiento bomba motorcompacto y motor con pie soporte.Cuerpo bomba en una sola pieza, abierto por un solo lado (barrielcasing), con boca de aspiración frontal sobre el eje de la bomba y bocade impulsión radial en la parte superior.Versión con variador de frecuencia (bajo demanda)

AplicacionesPara aprovisionamiento de agua.Para líquidos limpios, sin partes abrasivas, no agresivos para el aceroinoxidable (con adaptación, bajo demanda, de los materiales del sellomecánico).Bomba universal, para aplicaciones civiles e industriales, para jardi-nería e irrigación.

Límites de empleoTemperatura líquido de - 15 °C a + 110 °C.Temperatura ambiente hasta 40 °C.Presión máxima admitida en el cuerpo de la bomba: 10 bar.Servicio continuo.

MotorMotor a inducción 2 polos, 60 Hz (n = 3450 1/min).MXH: trifásico 220/380 V, 220/440 V, hasta 3 kW;

380/660 V, de 4 a 15 kW.Aislamiento clase F. Protección IP 54.Motor preparado al funcionamiento con convertidor de frecuencia.Clase alta eficiencia IE2 para motor trifásico de 0,75 kW a 5,5 kW,IE3 de 7,5 kW.Ejecución según: EN 60034-1;

EN 60034-30.

Otras ejecuciones bajo demanda- Bomba con orificios Victaulic (MXH-V) para 32, 48.- Bomba con bridas (MXH-F).- Otras tensiones.- Protección IP 55.- Sello mecánico especial.- Anillos de cierre cuerpo bomba en FPM.- Para ambientes con temperaturas más elevadas o más bajas.

DesignationMXH- F 32 04 - 60 *

SeriesNo code = threaded portsVictaulic ports VFlanged ports FRated capacity in m3/hNumber of stagesFrequency 60 Hz

Construction variants special seal code (no code = standard seal)

DesignaciónMXH- F 32 04 - 60 *

SerieSin indicación orificios roscadosOrificios con acoplamiento Victaulic VOrificios con bridas FCaudal nominal en m3/hNúmero de elementosFrequencia 60 Hz

Variantes costructivascódigo sello especial (sin indicación = sello estándar)

Page 17: MXH 2,4,8,16 60 HzSingle-piece barrel casing, with front suction port above pumps axis and radial delivery at top. Filling and draining plugs on the middle of the pump, accessible

113

Pumps with frequency converter

The MXH EI pumps are available with power from 3 kW up to 11 kW,

the pumps are equipped with I-MAT installed on board which allows to

realize a variable-speed system extremely compact and efficient, ideal

in applications of water supply and in

the distribution of hot and cold water.

The pump is equipped with

transducers suitable for operation and

is already programmed at the factory.

Advantages- Energy saving

- Compact design

- Easy to use

- Programmable to suit the system

requirements

- Reliability

CostructionThe system comprises of:

- Pump

- Induction motor

- I-MAT Frequency converter

- Motor adapter for the motor

mounting of the frequency converter

- Connection cable between

frequency converter and induction

motor

- Transducers

Main featuresRated motor power output from 3 kW to 11 kW

Control range from 1750 to 3450 rpm (2-pole)

Protection against dry running

Protection against operations with closed valve ports

Protection against system leakages

Protection against overcurrent in the motor

Protection agains overvoltage and undervoltage of the power supply

Protection against current unbalances between phases

Bomba a velocidad variable

La bomba MXH EI se encuentra disponible con potencias de 3 kW a

11 kW y llevan incorporado un variador I-MAT que permite realizar un

sistema de velocidad variable extremadamente compacto y eficiente, ideal

para aplicaciones de abastecimiento de agua

y la distribución de agua fría y caliente.

Bomba eléctrica es suministrada con un

transductor de presión idóneo para el modo

operación que escoja el cliente y programado

directamente desde fábrica

Ventajas- Ahorro de energía

- Diseño compacto

- Fácil de usar

- Programable para las necesidades del

sistema

- Fiabilidad

Construcción- El sistema está compuesto por:

- Bomba

- Motor de inducción

- I-MAT variador de frecuencia

- Adaptador del motor para el montaje del

variador de frecuencia

- Cable de conexión entre en variador y la

bomba eléctrica

- Transductores

Límites de utilizaciónPotencia nominal del motor desde 3 kW hasta 11 kW

Rango de control desde 1750 hasta 3450 rpm (2 polos)

Protección contra el funcionamiento en seco

Protección contra el funcionamiento con válvula cerrada

Protección contra fugas del sistema

Protección contra sobrecorriente del motor

Protección contra sobrevoltaje o bajovoltaje de la red de alimentación

Protección contra el desequilibrio de fases

MXH EIMXH EI 60 Hz60 Hz

Constant pressure mode with pressure transducer

In this mode, the system maintains the preset pres-

sure when the flow required by the installation

changes.

Proportional pressure mode with pressure transducer

In this mode the system changes the working pres-

sure according to the required flow rate.

Constant flow mode with flow meter

In this mode the system maintains a constant flow

rate value in a point of the installation according to

the required pressure.

Fixed speed mode with setting of the speed preferential rotation.

In this mode, by changing the working frequency,

you may choose any operational curve included

within the working range.

Constant temperature modewith temperature transducer

In this mode the system keeps the temperature

constant inside a system by changing the speed of

the pump.

Modo presión constante con sensor de presión

En el modo de presión constante, el sistema mantie-

ne la presión prefijada cuando cambia el caudal por

los cambios de la instalación.

Modo presión proporcional con sensor de presión

En el modo de presión proporcional, el sistema cam-

bia la presión de trabajo de acuerdo al caudal reque-

rido.

Modo caudal constante con medidor de caudal

En el modo caudal constante el sistema mantiene el

caudal constante en un punto de la instalación de

acuerdo a la presión requerida.

Modo velocidad fija con el ajuste de la velocidad de rotación preferencial

En el modo velocidad fija, cambiando la frecuencia

de trabajo, se puede escoger cualquier curva operati-

va dentro del rango de trabajo de la bomba.

Modo temperatura constantecon sensor de temperatura

En este modo el sistema mantiene la temperatura

constante dentro de un sistema cambiando la veloci-

dad de la bomba.

Operating modes Modos de operaciónH

Q

H

QH

Q

H

max

min

+-

+-

+ -

+-

075_124_2015 AM60__049_064_ING 60 08/04/16 17:04 Pagina 113

Page 18: MXH 2,4,8,16 60 HzSingle-piece barrel casing, with front suction port above pumps axis and radial delivery at top. Filling and draining plugs on the middle of the pump, accessible

114

Performance - Prestaciones n ≈ 3450 rpm

27

54

81

107

24,5

49

73,5

98

23,7

47,5

71

94,5

23

46

69

92

22

44

66,5

89

20,5

41,5

63,5

84,5

19

38,5

60

80

17,5

35

55

73,5

15

29

47,5

64,5

MXH 3201-60/A

MXH 3202-60/A

MXH 3203-60/A

MXH 3204-60/A

kW

4

7,5

11

15

HP

5,5

10

15

20

Qm /h

l/min

H m

3

3 ~ P2

633500

0

0

18

300

22

366

26

433

30 34

566

38 42

700

47

783

11

23

37,5

52

52

866

29,5

59

88,5

25,5

51

76,5

24,5

49

73,5

23

46

68,5

21

42,5

63,5

20

40,5

61

17,5

36,5

54,5

15

32

47,5

13

27,5

40,5

MXH 4801-60/A

MXH 4802-60/A

MXH 4803-60/A

kW

4

9,2

15

HP

5,5

12,5

20

Qm /h

l/min

H m

3

3 ~ P2

900750

0

0

27

450

33

550

39

650

45 48

800

54 60

1000

65

1083

10,5

23,5

34,5

70

1166

MXH 2001-60

MXH 2002-60

MXH 2003-60

MXH 2004-60

Qm /h

l/min

Hm

33 ~ P2

24,5

50

73

98

22,5

46

70

93

21,5

44,5

68

90

20

41,5

63

85

19

39,5

61

81

17,5

37

57

76

16

34

53

70

11

29

44

58

300233

0

0

9

150

12

200

20,5

43

66

88

14 16

266

18 20

333

22

366

25

416kW

3

4

5,5

7,5

HP

4

5,5

7,5

10

MXH MXH 20,32,4820,32,48 60 Hz60 Hz

Test results with clean cold water, without gas content.Resultados de las pruebas con agua fría y limpia, sin gas.

Rated currents - Intensidades nominales

P2 Rated motor power output.Potencia nominal del motor.

IA/IN D.O.L. starting current / Rated currentIntensidad de arranque / Intensidad nominal

34

5,57,59,21115

kW

45,57,510

12,515

18,5

13,4/7,7

HP IN A220/380V

three-phase - trifásico3~

-11,2/6,513,7/7,917/9,8

22/12,725,8/14,933,2/19,2

IN A380/660V

14,0/8,1

IN A220/440V

8,47,88,79,28,28,59,4

IA/IN

P2 Rated motor power output.Potencia nominal del motor.

+ 0,5 m security margin on NPSH-value is necessary.

Para el valor del NPSH se recomienda un margen de seguridad de + 0,5 m.

Tolerances according to UNI EN ISO 9906:2012.Tolerancias según UNI EN ISO 9906:2012.

Page 19: MXH 2,4,8,16 60 HzSingle-piece barrel casing, with front suction port above pumps axis and radial delivery at top. Filling and draining plugs on the middle of the pump, accessible

115

72.1035

ftm

m /h

l/min

ft

Pst

kWPst

m /h

NPSH

m

H

Q

Q

3

3

η

%η5

6

0

2

4

2

60

70

40

1000

200 250

50

6010 30

10 30

ft

50

60

70

70

104

6

040200

50

30

800600400200

Imp. g.p.m. 15010050

200

100

04020

60

70

80

90

40

20

30

10

0

0

3

0

0

72.9743

3

H

Q

Q

0 50

0

3

4

5

0

0

20

40

60

80

90

100

110

10

30

70

10 20 30 400

100

200

50 100 150Imp. g.p.m.

ft

m

200 400 600 800300 500 700

m /h

l/min

30

70

50

η

PstkW

Pst%

η

1

10

0 5010 20 30 40m /h0

4

NPSH

ft

m

0

20

8

300

200

900

72.9743

3

Q

Q

0 25

0

1

2

0

0

20

40

60

100

80

10

30

70

5 10 15 200

100

200

25 50 75U.S. g.p.m.

ft

100 200 300 400

m /h

l/min

40

80

60

η Pst

kW

Pst

%

η

0

10

0 5 10 15 20 25m /h0

4

NPSH

ft

m

0

20

8

90 300

100

Hm

MXH 3203

MXH 3204

MXH 3202

MXH 3201

MXH 4803

MXH 4802

MXH 4801

MXH 2003

MXH 2004

MXH 2002

MXH 2001

Characteristic curves - Curvas Características n ≈ 3450 rpm

MXH MXH 20,32,4820,32,48 60 Hz60 Hz

Page 20: MXH 2,4,8,16 60 HzSingle-piece barrel casing, with front suction port above pumps axis and radial delivery at top. Filling and draining plugs on the middle of the pump, accessible

116

Dimensions and weights - Dimensiones y pesos

a

fM

DN2

DN

1

w

m5

140

Hm4

s1

w1

h1

aV

fMV

DN2

DN

117

7

aF

fMF

DN2

DN

117

5

L

n5

n4

b1 AA

g2

g2*

HA

ISO 228DN2DN1

507

521

561

596

482

534

658

779

545

643

779

MXH 2001-60MXH 2002-60MXH 2003-60MXH 2004-60MXH 3201-60/AMXH 3202-60/AMXH 3203-60/AMXH 3204-60/AMXH 4801-60/AMXH 4802-60/AMXH 4803-60/A

127

127

146

180,5

120,5

120,5

166,5

212,5

136

136

197,5

fM a

mm

G 1 1/2

G 1 1/2

G 1 1/2

G 1 1/2

G 2

G 2

G 2

G 2

G 2 1/2

G 2 1/2

G 2 1/2

160

160

206

252

175

175

237

aV

522

574

698

819

585

683

819

76,1 (DN65)

76,1 (DN65)

76,1 (DN65)

76,1 (DN65)

88,9 (DN80)

88,9 (DN80)

88,9 (DN80)

60,3 (DN50)

60,3 (DN50)

60,3 (DN50)

60,3 (DN50)

76,1 (DN65)

76,1 (DN65)

76,1 (DN65)

fMV

G 2

G 2

G 2

G 2

G 2 1/2

G 2 1/2

G 2 1/2

G 2 1/2

G 3

G 3

G 3

DN2DN1

mm

mm

mm

MXH-V 3201-60/AMXH-V 3202-60/AMXH-V 3203-60/AMXH-V 3204-60/AMXH-V 4801-60/AMXH-V 4802-60/AMXH-V 4803-60/A

161,5

161,5

180,5

215

151

151

197

243

156

156

218

aF

542

556

596

631

512

564

688

809

565

663

799

50

50

50

50

65

65

65

65

80

80

80

40

40

40

40

50

50

50

50

65

65

65

fMF

DN2DN1

mm

mm

mm

MXH-F 2001-60MXH-F 2002-60MXH-F 2003-60MXH-F 2004-60MXH-F 3201-60/AMXH-F 3202-60/AMXH-F 3203-60/AMXH-F 3204-60/AMXH-F 4801-60/AMXH-F 4802-60/AMXH-F 4803-60/A

130

130

190

190

140

190

216

216

140

216

216

30

38

50

55

39

55,5

41

110

kg

250

250

250

250

250

250

270

270

250

270

270

L

175

175

250

250

175

250

178

178

175

178

178

m5

170

170

258

258

180

258

260

260

180

260

260

280

290

310

310

290

310

318

318

290

318

318

n4 n5 w1 AA s1 wH

150

150

150

150

150

150

132

132

150

132

132

h1

15

15

15

15

15

15

20

20

15

20

20

-

-

-

-

-

-

52

52

-

52

52

b1

54

54

68

68

54

68

-

-

54

-

-

10

10

12

12

10

12

12

12

10

12

12

95

95

84

84

112

84

171,5

171,5

127

186,5

186,5

g2

-

-

38

38

-

38

-

-

-

-

-

g2*

6*

6*

-

-

6*

-

-

-

6*

-

-

HA

-

-

-

-

-

-

18

18

-

18

18

205

205

280

280

205

280

218

218

205

218

218

m4

Victaulic ports

Threaded ports

Flanged ports

165

DEDN

185

125

DK

145

4

4

99

DG

118

19

19

50

150 110 481 1940

65

200 160 8132 1980

Flanges* EN 1092-2

* ASME 150 lb (ex ANSI 150 lb)

N. Ø

DN

DK

DG

DE

MXH MXH 20,32,4820,32,48 60 Hz60 Hz

Orificios roscados

Acoplamiento Victaulic Orificios con bridas

TYPETIPO

TYPETIPO

TYPETIPO

HolesAguijeros

Page 21: MXH 2,4,8,16 60 HzSingle-piece barrel casing, with front suction port above pumps axis and radial delivery at top. Filling and draining plugs on the middle of the pump, accessible

117

Features - Características constructivas

FlexibilityThree versions of ports: threaded, flanged and Victaulic.

Extra safetyWith front axis suction port for optimum suction conditions.

ReliableAll hydraulic parts in contact with the pumped liquid are madein stainless steel. For liquids from -15 °C to 110 °C.

RobustSingle-piece, thick barrel casing, open on one side only, withreinforced threaded ports.

CompactThe bracket between pump and motor is extremely compact.

Greater protectionAgainst leakage, with the pump casing cover separated fromthe motor shield. Possibility of inspecting the seal through the side aperturesbetween the two walls.

MXH MXH 20,32,4820,32,48 60 Hz60 Hz

FlexibleDiferentes versiones de orificios: roscados, victaulic y conbrida.

Más seguridadCon la boca de aspiración frontal para una mejor capacidadde aspiración.

FiableTodas las partes hidráulicas en contacto con el líquido son deacero inoxidable. Para líquidos de -15 °C a +110 °C.

RobustaCuerpo bomba de una sola pieza de grueso espesor, abiertopor un solo lado, manguitos de aspiración y impulsión renfor-zados.

CompactaAcoplamiento bomba motor muy compacto.

Mayor protecciónContra las pérdidas del cierre, con la tapa de la bomba sepa-rada de la tapa del motor. Posibilidad de inspección del sello mecánico a través de laabertura lateral entre las dos paredes.