2
OK® Adhesive type 4 Indicator Strip Steam Sterilization Once-A-Day ® Ecos Bowie-Dick Test Pack ISO 11140-1, Type 2: 11140-4 Onix™ Helix Process Challenge Test for Table Top Sterilizers ISO 11140-1, EN 867-5 Onix™ Helix Process Challenge Test for Large Chamber Sterilizers ISO 11140-1 Emu-Chex™ Type 6 Indicators ISO 11140-1, Type 6 Detects sterilizer malfunctions according to Bowie-Dick Protocol, Temperature Range: 134-137° Guaranteed distinct blue to pink color change that will not revert Distinct color changes indicate specific cause of failure, including: residual air, wet steam, over-exposure and low temperature conditions Compact size for economy shipping and storage Lead and Heavy Metal Free Cat No. 26611500 Ecos Bowie Dick Test 30 packs/case Onix™ Helix Type Bowie-Dick Test ISO 11140-1, Type 2: 11140-4 Detects sterilizer malfunctions according to Bowie-Dick Protocol Temperature Range: 134°C, 3.5 minutes Stable White to Black indicator change, can be maintained for record keeping Multi-use device reduces waste, labor and cost Cat No. 26620300 Onix Helix Bowie Dick Device - 1 device Cat No. 26911400 Helix Bowie Dick Indicator Strip, 250 Strips Cat No. 26642300 HT Helix Bowie Dick Device - 1 device + 250 Strips Simulates complex lumen containing instruments Pass result ensures adequate sterilant penetration into difficult to sterilize instruments Conforms to EN 867-5 Table top, Temperature Range: 121-135°C Stable indicator ink result will not revert after processing Multi-use device lasts 250 cycles, reduces waste, labor and cost Cat No. 26910900 Onix Helix Device, 1 device + 250 strips Cat No. 26911300 Helix PCD Strips, 1 device + 250 strips Durable plastic body lasts 250 cycles, Temperature Range: 121-135°C White to black color change indicates successful sterilization Cat No. 26942200 HT Helix PCD, 1 device + 250 strips Cat No. 26942100 HT Helix Bowie Dick Device, 1 device + 250 strips Monitors critical cycle parameters of steam sterilization Size 10cmx1.5cm Lead and heavy metal free Laminated for durability Stable indicator ink result will not revert and will not bleed in wet cycles Cat No. 26611600, 121°C, 20min Cat No. 26611700, 132°C, 4min Cat No. 26611800, 135°C, 3min Cat No. 26611900, 134°C, 3.5min Cat No. 26612100, 134°C, 5min/121°C. 15min Cat No. 26511800, 134°C, 18min Cat No. 26612200, 134°C, 7min/121°C, 20min Type 4 Chemical Indicator Strip, 3.2cmx1.9cm Temperature Range: 121-135°C Adhesive layer on back splits into two parts, one attaches to item to be sterilized and the other peels to easily attach to record keeping documents Cat No. 26410900 250 OK Adhesive Type 4 Indicator Strips Monitors efficacy of UV lamps and other sources of UV radiation, Size: 10cm x 1.5cm Integrates intensity of radiation and time Monitors difficult locations that UV meters cannot reach Color Change will not revert Measures up to: 36J/m2 UVA, 75 J/m2 UVB, 1868J/m2 ISED Sunlight Cat No. 264106000 250 UV Indicator Strips UV Indicator Strip New International Products in Addition to the Complete Catalog Uv Dosage Monitoring ISO 11140-1:2014

New International Products in Addition to the Complete Catalog Steam …prolinemedical.com.au/wp-content/uploads/2018/05/International-Pr… · • Monitors critical cycle parameters

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

  • OK® Adhesive type 4 Indicator Strip

    Steam SterilizationOnce-A-Day ® Ecos Bowie-Dick Test Pack ISO 11140-1, Type 2: 11140-4

    Onix™ Helix Process Challenge Test for Table Top Sterilizers ISO 11140-1, EN 867-5

    Onix™ Helix Process Challenge Test for Large Chamber Sterilizers ISO 11140-1

    Emu-Chex™ Type 6 Indicators ISO 11140-1, Type 6

    • Detects sterilizer malfunctions according to Bowie-Dick Protocol, Temperature Range: 134-137°• Guaranteed distinct blue to pink color change that will not revert• Distinct color changes indicate specific cause of failure, including:

    residual air, wet steam, over-exposure and low temperature conditions• Compact size for economy shipping and storage• Lead and Heavy Metal Free

    Cat No. 26611500 Ecos Bowie Dick Test 30 packs/case

    Onix™ Helix Type Bowie-Dick Test ISO 11140-1, Type 2: 11140-4• Detects sterilizer malfunctions according to Bowie-Dick Protocol• Temperature Range: 134°C, 3.5 minutes• Stable White to Black indicator change, can be maintained for record keeping• Multi-use device reduces waste, labor and cost

    Cat No. 26620300 Onix Helix Bowie Dick Device - 1 deviceCat No. 26911400 Helix Bowie Dick Indicator Strip, 250 StripsCat No. 26642300 HT Helix Bowie Dick Device - 1 device + 250 Strips

    • Simulates complex lumen containing instruments• Pass result ensures adequate sterilant penetration into difficult to sterilize instruments• Conforms to EN 867-5 Table top, Temperature Range: 121-135°C• Stable indicator ink result will not revert after processing• Multi-use device lasts 250 cycles, reduces waste, labor and cost

    Cat No. 26910900 Onix Helix Device, 1 device + 250 stripsCat No. 26911300 Helix PCD Strips, 1 device + 250 strips

    • Durable plastic body lasts 250 cycles, Temperature Range: 121-135°C• White to black color change indicates successful sterilization

    Cat No. 26942200 HT Helix PCD, 1 device + 250 stripsCat No. 26942100 HT Helix Bowie Dick Device, 1 device + 250 strips

    • Monitors critical cycle parameters of steamsterilization

    • Size 10cmx1.5cm• Lead and heavy metal free• Laminated for durability• Stable indicator ink result will not revert and will

    not bleed in wet cycles

    Cat No. 26611600, 121°C, 20minCat No. 26611700, 132°C, 4minCat No. 26611800, 135°C, 3minCat No. 26611900, 134°C, 3.5minCat No. 26612100, 134°C, 5min/121°C. 15minCat No. 26511800, 134°C, 18minCat No. 26612200, 134°C, 7min/121°C, 20min

    • Type 4 Chemical Indicator Strip, 3.2cmx1.9cm• Temperature Range: 121-135°C• Adhesive layer on back splits into two parts, one attaches to item to be

    sterilized and the other peels to easily attach to record keeping documentsCat No. 26410900 250 OK Adhesive Type 4 Indicator Strips

    • Monitors efficacy of UV lamps and other sources of UV radiation, Size: 10cm x 1.5cm• Integrates intensity of radiation and time• Monitors difficult locations that UV meters cannot reach• Color Change will not revert• Measures up to: 36J/m2 UVA, 75 J/m2 UVB, 1868J/m2 ISED Sunlight

    Cat No. 264106000 250 UV Indicator Strips

    UV Indicator Strip

    New International Products in Addition to the Complete Catalog

    Uv Dosage Monitoring

    ISO 11140-1:2014

  • Washer Test Soil

    VH2O2 SterilizationPlasma-Chex™ Vaporized H2O2 Indicator Strip ISO 11140-1:2014, Type 1

    BI-OK® Plasma Vaporized H2O2 Biological Indicator ISO 11138-1

    Protein test, Short and Long Swab

    • Monitors all critical cycle parameters of vaporized hydrogen peroxide cycles, Size 10cm x1.5cm• Distinct color change will not fade, revert or change when exposed to light or wet conditions• Suitable for hydrogen peroxide sterilizers with and without plasma phase

    Cat No. 26701800 Plasma-Chex Strips, 250/bag

    • Monitors vaporized hydrogen peroxide sterilizers with and without plasma phase• Distinct color change from purple to pink will not fade or revert

    Cat No. 26801000 Plasma Chex Tape Roll, 25mmx50mm, 36 rolls/case

    • Monitors vaporized hydrogen peroxide sterilizers with and without plasma phase• Results in 24hr incubation; media change from red to yellow• Label has process indicator, label can be written on for record keeping• Standard size vial fits most BI Incubators

    Cat No. 26923200 BI-OK Plasma Vials, 20/pouch

    • Monitors the critical parameters of sterilization:time and temperature• Distinct color change from light blue to brown will not revert• For use in every package in every load, suitable for record keeping• Adhesive layer on back splits into two parts, one attaches to item to be sterilized

    and the other peels to easily attach to record keeping documentsCat No. 26101800 Hi-Dri Indicator Strips; 180°C, 60 minutes, 250/pouch

    Washer Disinfector Indicator

    Plasma-Chex™ Vaporized H2O2 Indicator Tape ISO 11140-1:2014, Type 1

    Hi-Dri Dry Heat Adhesive Indicator ISO 11140-1:2014, Type 4Dry Heat Sterilization

    Cleaning Efficacy

    • Provides visual check within 5 seconds for residual proteins on surgical instruments or inendoscope channels, with no incubation

    • Clear color change from brown to blue/green in the presence of protein, 1 ug sensitivityCat No. 26923300 - Short Swab Protein Test, 30/boxCat No. 26923400 - Long Lumen Swab Protein Test, 2.5m long, 2.8mm diameter, 4 vials, 3 test + 1 control

    • Designed to mimic biological material soiling that ccumulates naturally during use of medicalinstruments, laboratory glassware and other materials

    • Provides a simple way to challenge the cleaning efficacy of washer-disinfectors, validate washercycles and load configurationsCat No. 26100400 - Test Soil Pots and applicators 6/case

    • Responds to time, temperature, detergent concentration and agitation in washer-disinfector cycle• Presence of leftover indicator residue gives clear indicators of insufficient cleaning• Does not introduce blood to the wash cycle

    Cat No. 26310200 Washer Disinfector Indicator Strips, 250 strips/pouch

    Sonic-Chex Ultrasonic Bath Monitor Strip• Responds to time, temperature, detergent presence and cavitation in ultasonic cleaning cycles• Suitable for Ultrasonic cleaners with and without disinfection• Demonstrates sufficient cleaning with blue ink is fully cleaned to reveal white background

    Cat No. 26210200 Sonic-Chex Ultrasonic Bath Monitor strips, 100 strips/pouch

    ISO 15883-5

    PROLINE MEDICAL | [email protected] | www.prolinemedical.com.auUnit 5, 116 Lipscombe Rd, Deception Bay Queensland | P: +61(0) 0408 610 851

    95000007 Rev 10/16