ElectronicPressure Measurement
R
OEM Pressure TransmitterFor General Industrial ApplicationsModel O-10
WIKA Datasheet O-10
Model O-10 Pressure TransmitterLeft: O-10 with cable, Center: O-10 with M12x1,
Right: O-10 with miniDIN style electrical connections.
Applications
Hydraulics and pneumatics Pumps and compressors Machine controls Building services
Special Features
Pressure ranges from 100 psi to 8000 psi Nonlinearity≤0.5% Availableoutputsignalsinclude4…20mA,0…10V,0…5V, 1…5V,0.5…4.5V,0.5V…4.5Vratiometric Electrical connections: male form A or C DIN connections, M12x1 4-pin, 6-foot cable, others Processconnections:¼”NPT,⅛”NPT,7/16-20 UNF O-ring boss, G¼, PT¼, G¼ female and others
Description
The Model O-10 pressure transmitter is designed to meet the pressure measurement requirements in many industrial and commercialapplications.TheO-10features,specifications,and price make it suitable for OEM applications with an annual quantityofmorethan1000unitsperpartnumber.Theminimumreleasesizeis50pieces.
TheO-10isavailableinalargenumberofconfigurationstomeetmanyapplicationrequirements.Optionsincludemanyavailable process and electrical connections as well as all industrystandardpressurerangesandoutputsignals.
The O-10 is German-engineered and manufactured to meet globalmarketrequirements.Internationalpressureunitsandprocess connections are available to meet global requirements.ApprovalsincludingULandGOSTarepending.
The O-10 can be private labeled with customer logo and modelnumberifrequired.
WIKA Datasheet O-10 ·10/2011 Page 1 of 6
Pressure rangesRelative pressure
psi 00......100600
00......160750
00......200800
00......2501000
00......3001500
00......4002000
00......5003000
0...4000 0...5000 0...6000 0...7500 0...8000bar 0...6 0...10 0...16 0...25 0...40 0...60 0...100
0...160 0...250 0...400 0...600
Vacuum and +/- measuring range
psi -30inHg...+100 -30inHg...bar -1...+5 -1...+9
+160 -30inHg-1...+15
...+200 -30inHg-1...+24
...+300 -30inHg-1...+39
...+500-1...+59
The listed pressure ranges are also available in kg/cm2,kPaandMPa.Othermeasuringrangesonrequest.
Overpressure limit2times(3timesonrequest)
Vacuum resistanceYes
Output signalSignal type Value
Current (2-wire) 4...20mAVoltage (3-wire) DC0...10V
DC0...5VDC1...5VDC0.5...4.5V
Ratiometric (3-wire) DC0.5...4.5V
Otheroutputsignalsavailableonrequest.
Load in ΩCurrent(2-wire): ≤(powersupply-7V)/0.02AVoltage(3-wire): > Umax / 1 mARatiometric(3-wire): >4.5k
Voltage supplyPower supplyCurrent output: DC8...30VVoltage output: DC8...30VVoltageoutput(0...10V): DC14...30VRatiometric output: DC5V±10%
The power supply for the pressure transmitter must be made via an energy-limited electrical circuitinaccordancewithsection9.3ofUL/EN/IEC61010-1oranLPStoUL/EN/IEC60950-1orclass2perUL1310/UL1585(NECorCEC).Thepowersupplymustbesuitableforoperationabove6500ft.shouldthepressuretransmitterbeusedatthisaltitude.
Total current consumptionCurrent output: Signalcurrent,maximum25mAVoltage output: 5mA
Page 2 of 6 WIKA Datasheet O-10 · 10/2011
AccuracyNon-linearity (IEC 61298-8)≤±0.5%ofspanBFSL
Forpressureranges0...100psi,0...6bar,0...10barthefollowing applies:≤±0.6%ofspanBFSL
Zero offset≤±0.5%ofspan
Forpressureranges0...100psi,0...6bar,0...10barthefollowing applies:≤±0.7%ofspan
Accuracy at room temperature≤±1.2%ofspan
Temperature error (from 0 ... 80 °C)≤±1.5%ofspan
Long-term stability≤±0.3%ofspan(peryear)
Settling time< 2 ms
Reference conditions (per IEC 61298-1)Temperature: 59...77°F(15...25°C)
28...31inchesofmercuryAtmospheric pressure: (950...1050mbar)Humidity: 45...75%relativePower supply: DC 24 V
Operating conditionsVibration resistance20g(20...2000Hz,120min.)perIEC60068-2-6(vibrationunderresonance)
Shock resistance40g(6ms)perIEC60068-2-27(mechanicalshock) Service life≥10millionloadcycles
Impact resistanceResistanttoanimpactontoconcretefrom3ft
TemperaturesOperation: -22...+212°F(-30...+100°C)Storage: -22...+212°F(-30...+100°C)
Process connectionsStandard ThreadEN 837 G 1/8 B 2)
G 1/4 BG 1/4 femaleG3/8B
3)DIN 3852-E G 1/4 A 1)3)M14x1,5
ANSI/ASME B1.20.1 1/8 NPT 2)1/4 NPT 1)
1/4 NPT femaleISO 7 R 1/4 1)
R3/84)KS PT 1/4 1)
4)PT3/81)SAE 7/16-20UNFO-ringBOSS
9/16-18UNFO-ringBOSSAll process connections are available, as standard, with a pressure portwithadiameterof3.5mm.
1)Optionaldiameters6mm,0.6mm,0.3mmonrequest.2)Maximummeasuringrange6000psi(400bar).3)SealingmaterialavailableinNBRandFPM/FKM.4)SealingmadeofFPM/FKM.
MaterialsNon-wetted parts316Lstainlesssteel,PBTGF30
Wetted parts316Lstainlesssteel,13-8PH
Approvals, directives and certificates
CE conformity
EMC directive2004/108/EC EN61326emission(group1,classB)andinterferenceimmunity(industrialapplication)
Pressure equipment directive97/23/EC
RoHS conformityYes
WIKA Datasheet O-10 · 10/2011 Page3of6
Angular connector DIN 175301-803 A
AssignmentUB 0V S+
2-wire 1 2 -3-wire 1 2 3
Angular connector DIN 175301-803 C
AssignmentUB 0V S+
2-wire 1 2 -3-wire 1 2 3
Circular connector M12 x 1, 4-pin
AssignmentUB 0V S+
2-wire 1 3 -3-wire 1 3 4
Cable outlet, unshielded
AssignmentUB 0V S+
2-wire brown green -3-wire brown green white
Cable outlet, shielded
AssignmentUB 0V S+
2-wire brown blue -3-wire brown blue black
Electrical connectionsSpecifications
Description Ingress protection Cable material
Angular connector DIN 175301-803 A IP65 -Angular connector DIN 175301-803 C IP65 -Circular connector M12 x 1 (4-pin) IP67 -Cable outlet, unshielded (2 m) 1) IP67 PVCCable outlet, shielded (2 m) IP67 PVC
1)uptoamaximumof80°Cpermitted
Thestatedingressprotection(perIEC60529)onlyapplieswhenpluggedinusingmatingconnectorsthathavetheappropriateingressprotection.
Otherconnectionsavailableonrequest(e.g.MetriPack150series).
Matingconnectorarenotincludedinthedelivery.Matingconnectors(withandwithoutcable)areavailableasaccessoriesatadditionalcost.
Electrical safetyShort-circuitresistance: S+vs.0VReverse polarity protection: UBvs.0VOvervoltage protection: DC36VIsolation voltage: DC750V
Connection diagram
Page 4 of 6 WIKA Datasheet O-10 · 10/2011
with angular connector form A with angular connector form C with M12 x 1 circular connector
Dimensions in mm (25.4 mm = 1 inch)
Pressure transmitter
with cable outlet
G L1G1/4ADIN3852-E 14M14x1.5 14
G L1G1/4BEN837 13G3/8BEN837 16
G L1G1/8BEN837 10
Weight:approx.80g Weight:approx.80g Weight:approx.80g
Weight:approx.80g
Process connections
G L19/16-18UNFBOSS 137/16-20UNFBOSS 12
WIKA Datasheet O-10 · 10/2011 Page5of6
G L11/4 NPT 13R 1/4 13R3/8 15PT 1/4 13PT3/8 15
G L1 L2 L3 D1G 1/4 20 15 12 Ø25
G L1 L2 L31/4 NPT 20 14 Ø25
Process connections
Forinformationontappedholesandweldingsockets,seeTechnicalInformationIN00.14atwww.wika.com.
Accessories and spare partsMating connector
Order numberwithout cable with 6 ft cable with 15 ft cable
Angular connector DIN 175301-803 A with cable gland, metric with cable gland, conduit
Angular connector DIN 175301-803 CCircular connector M12 x 1 (4-pin)
straight angled
11427567110224851439081
24212622421270
11225793-11225823
1125078011250798
11250186-11250194
1125025911250232
Seals for mating connectors
Order numberAngularconnectorDIN175301-803AAngularconnectorDIN175301-803C
157624011169479
Useofaccessoriesotherthanthoselistedabovemayinvalidateproductapprovals.
Ordering informationModel / Pressure range / Output signal / Process connection / Electrical connection
©2011WIKAInstrumentCorporation,allrightsreserved.Thespecificationsgiveninthisdocumentrepresentthestateofengineeringatthetimeofpublishing.Wereservetherighttomakemodificationstothespecificationsandmaterials.
Page 6 of 6 WIKA Datasheet O-10 · 10/2011
R
WIKA Instrument Corporation 1000 Wiegand Boulevard Lawrenceville,GA30043-5868Tel: 888-WIKA-USA•770-513-8200Fax: 770-338-5118E-Mail: [email protected]