Upload
hockchilato
View
476
Download
13
Tags:
Embed Size (px)
DESCRIPTION
SP3D Cable Tray Specfication
Citation preview
Process Power and Marine DivisionProcess, Power and Marine DivisionSmartPlant 3D (SP3D)Oglaend Cable Ladder & Tray SpecificationsOglaend Cable Ladder & Tray Specifications
Oglaend Catalogue 2012
SP3D : Contents
• Introduction – Cable Ladder & Cable Tray Slides 3 - 11 Introduction Cable Ladder & Cable Tray Slides 3 11 • OE Cable Ladder System Slides 12 - 22• FOE Cable Ladder System Slides 23 - 33• LOE Cable Ladder System Slides 34 - 46LOE Cable Ladder System Slides 34 46• FTE Cable Tray System Slides 47 - 53• SPB Cable Tray System Slides 54 - 63• SP3D Oglaend Reports Slides 64 - 66SP3D Oglaend Reports Slides 64 66• SP3D Oglaend Specifications Set-up Slides 67 - 78
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue
Oglaend Cable Ladder and TraySP3D Specification
SP3D representation
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
representation
SP3D : Oglaend Catalogue
Oglaend Cable Ladder and TraySP3D Specification
Th f ll i t ti i d i d tThe following presentation is designed to cover :
An overview of each SP3D Oglaend specification including -
• Design of specifications• Selection of Cable Ladder and Tray types• Loading of particular specification to cover project requirements• Loading of SP3D Oglaend Reports
S3D version required minimum S3D Preferred version SP3D 2009.1 Hot FIX 26 S3D 2011 R1
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue
Oglaend Cable Ladder and TraySP3D Specification
Based on SP3D Cable part definition :
– Allowing easy change of SP3D specification– Selection of Cable Ladder and Tray types
L di f i l ifi i j i• Loading of particular specification to cover customer project requirements
– Recommended work flow• Read the following information • Choose the specifications required for your project• Refer to the load instructions at the end of this document
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Ladder
Oglaend Cable Ladder and TraySP3D Specification
SP3D representation
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Ladder
Designed to cover OglaendCable Ladder
C bl L dd t U Lidd dCable Ladder systems Un-Lidded
– OE OE-100, OE-125, OE-150 (Heavy Duty)– FOE FOE-70, FOE-100, FOE-150, FOE-150GA– LOE LOE-55, LOE-75, LOE-100 (Medium \ Light duty)
OE
( g y)
– Standard length : 3 metres
– OE offered in material finishes of :• Hot Dipped Galvanized (HDG) FOEHot Dipped Galvanized (HDG)• Stainless Steel (SS)
– LOE offered in material finishes of :• Hot Dipped Galvanized (HDG)
St i l St l (SS)
FOE
• Stainless Steel (SS)• Pre-Galvanized (PG)
– FOE offered in material finishes of:• Polyester Resin
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
All SP3D specification types being designed for open requirements only LOE
SP3D : Oglaend Catalogue : Ladder
Designed to cover Oglaend Cable LadderCable Ladder systems Lidded
– OE OE-100, OE-125, OE-150 (Heavy Duty), , ( y y)– FOE FOE-70, FOE-100, FOE-150, FOE-150GA– LOE LOE-55, LOE-75, LOE-100 (Medium \ Light duty)
– Lidded specifications have a CO in their name to designate Covered.– The covers are implied and have no graphical representation
OE
– The covers are implied and have no graphical representation
– Standard length : 3 metres
– OE offered in material finishes of :H t Di d G l i d (HDG) FOE• Hot Dipped Galvanized (HDG)
• Stainless Steel (SS)
– LOE offered in material finishes of :• Hot Dipped Galvanized (HDG)
FOE
( )• Stainless Steel (SS)• Pre-Galvanized (PG)
– FOE offered in material finishes of:• Polyester Resin
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
Polyester Resin
All SP3D specification types being designed for open requirements only LOE
SP3D : Oglaend Catalogue : IEC Trays
Oglaend Cable Trays SP3D Specification
SP3D representation
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Cable Trays
Designed to Cover Oglaend Cable trays
Cable Ladder systems Un-Lidded
– FTE FTE-50, FTE-80– SPB SPB-20, SPB-40, SPB-RF
FTE
– FTE offered in material finishes of :• Polyester Resin (C1, C2)
– SPB offered in material finishes of :SPB offered in material finishes of :• Hot Dipped Galvanized (HDG)• Stainless Steel (SS)• Pre-Galvanized (PG)
SPB RF offered in material finishes of:
SPB
– SPB-RF offered in material finishes of:• Hot Dipped Galvanized (HDG)• Stainless Steel (SS)
SPB-RF
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
All SP3D specification types being designed for open requirements only
SP3D : Oglaend Catalogue : Cable Trays
Designed to Cover Oglaend Cable trays
Cable Ladder systems Lidded
– FTE FTE-50, FTE-80– SPB SPB-20, SPB-40, SPB-RF
– Lidded specifications have a CO in their name to designate Covered.
FTE
Lidded specifications have a CO in their name to designate Covered.– The covers are implied and have no graphical representation
– FTE offered in material finishes of :• Polyester Resin (C1, C2)
– SPB offered in material finishes of :• Hot Dipped Galvanized (HDG)• Stainless Steel (SS)• Pre-Galvanized (PG)
SPB
( )
– SPB-RF offered in material finishes of:• Hot Dipped Galvanized (HDG)• Stainless Steel (SS)
SPB-RF
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.All SP3D specification types being designed for open requirements only
SP3D : Oglaend Catalogue : Ladder : OE range
Oglaend OE-100, 125, 150 Ladder specification (Heavy Duty System )
Side rail height : 100mm 125mm 150mm Side rail height : 100mm, 125mm, 150mm Available cabling space : 75mm, 100mm, 125mm Available widths : 150, 300, 450, 600, 750, 900mm
S li d t d d i 3 t l th Supplied as standard in 3 meter lengths Connections by splice plate
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Ladder : OE range
Oglaend open Ladder specification
The specification is designed to place OE fittings in both manual and sketch modes
Understanding of the specification is imperative to efficient construction and material hpurchase
Falling into two remits :
– Sketch mode : being the most effective manner to place– Sketch mode : being the most effective manner to place– Manual mode : used in restricted environments allowing manual modification and
selection of individual fittings
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Ladder : OE range
Oglaend OE open Ladder specification
Designed around a series of specifications :By Material &Height
Cableway selection of Oglaend Specifications
– By Material &Height• OGD_OE-100/125_HDG_ Hot dipped galvanized• OGD_OE-100/125_SS Stainless steel• OGD_OE-150_HDG_ Hot dipped galvanized• OGD_OE-150_SS Stainless steel Selection of Specifications with routing Command
Materials to be loaded are specified in the load file Allocation of Usable Cable Space, defined by specification
Load Width & Depth
Selection Radius with routing Command
Selection of width’s and radius during Placement
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
Selection of width s and radius during Placement
SP3D : Oglaend Catalogue : Ladder : OE range
Oglaend OE open Ladder specification - connecting length to length
OE straight lengths require splice connector for straight to Straight OE straight lengths require splice connector for straight to Straight connections
– when connecting a straight to a straight, two splice plates are generated.g
– The splice plates are not modeled or detailed in the SP3D parts list but are controlled by a specification level rule and will appear on a splice plate report.
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Ladder : OE range
Oglaend OE open Ladder specification - connecting length to fitting
OE straight lengths require splice connector for straight to fitting OE straight lengths require splice connector for straight to fitting connections
– When connecting a straight to a fitting, one splice plate is generated as the fitting is already delivered with a splice plate.g g y p p
– The splice plates are not modeled or detailed in the SP3D parts list but are controlled by a specification level rule and will appear on a splice plate report.
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Ladder : OE range
Oglaend OE open Ladder specification - connecting fitting to fitting
OE fittings require a splice connector for straight to fitting connections OE fittings require a splice connector for straight to fitting connections – When connecting a fitting to a fitting, no splice plate is generated
as each fitting is supplied with the required number splices by Oglaend.Oglaend.
– The splice plates are not modeled or detailed in the SP3D parts list but are controlled by a specification level rule and will appear on a splice plate report.
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Ladder : OE range
The specification is designed to place Oglaend fittings in both manual and sketch modes
Oglaend OE open Ladder specification – Flat Bends
in both manual and sketch modes
Flat bends have fixed angles of 30/45/60/90’
B d il bl ith 600 900 di Bends are available with 600mm or 900mm radius
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Ladder : OE range
Oglaend OE open Ladder specification– Inside or Outside Risers
The specification is designed to place Oglaend fittings in both manual and sketch modesp g p g g
Flexi Risers have variable angles and can be used for 30/45/60/90’. Number of segments may differ per angle & radius.
Riser radius should set prior to placementFlexi RiserRiser radius should set prior to placement
Flexi Risers should be placed manually to ensure correct selection Combi Risers are available for 90 and 45deg vertical bends
Riser
Combi Riser
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Ladder : OE range
The specification is designed to place Oglaend fittings in both manual and sketch modes
Oglaend OE open Ladder specification – Equal & Unequal Tees
manual and sketch modes
Fixed Tees and Unequal tees have are available in 600mm and 900mm radius.
Manual placement allows selection of specific fittingsManual placement allows selection of specific fittings
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Ladder : OE range
Oglaend OE open Ladder specification– Left Hand & Right Hand Reducers
The specification is designed to manually place Oglaend offset reducer fittings. Automatic placement is not valid.
Ri ht H d R d
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
Left Hand ReducerRight Hand Reducer
SP3D : Oglaend Catalogue : Ladder : OE range
The specification is designed to manually place Oglaend C fitti A t ti l t i t lid
Oglaend OE open Ladder specification– Equal Crosses
Cross fittings. Automatic placement is not valid.Available in 600mm and 900mm radius.
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Ladder : FOE range
Oglaend FOE-100, 125, 150 Ladder specification
Side rail height : 70mm 100mm 150mm Side rail height : 70mm, 100mm, 150mm Available cabling space : 46mm, 71mm, 121mm Available widths : 150, 200, 300, 400, 450, 500, 600mm
S li d t d d i 3 t l th Supplied as standard in 3 meter lengths Connections by splice plate
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Ladder : FOE range
Oglaend open Ladder specification
The specification is designed to place FOE fittings in both manual and sketch modes
Understanding of the specification is imperative to efficient construction and material hpurchase
Falling into two remits :
– Sketch mode : being the most effective manner to place– Sketch mode : being the most effective manner to place– Manual mode : used in restricted environments allowing manual modification and
selection of individual fittings
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Ladder : FOE range
Oglaend OE open Ladder specification
Designed around a series of specifications :By Material &Height
Cableway selection of Oglaend Specifications
– By Material &Height• OGD_FOE-70_C2 Polyester Class 2• OGD_FOE-100_C1 Polyester Class 1• OGD_FOE-150_C1 Polyester Class 1• OGD_FOE-150_GA_C1 Polyester Class 1 Selection of Specifications with routing Command
Materials to be loaded are specified in the load file Allocation of Usable Cable Space, defined by specification
Load Width & Depth
Selection Radius with routing Command
Selection of width’s and radius during Placement
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
Selection of width s and radius during Placement
SP3D : Oglaend Catalogue : Ladder : FOE range
Oglaend FOE open Ladder specification - connecting length to length
FOE straight lengths require splice connector for straight to Straight FOE straight lengths require splice connector for straight to Straight connections
– when connecting a straight to a straight, two splice plates are generated.g
– The splice plates are not modeled or detailed in the SP3D parts list but are controlled by a specification level rule and will appear on a splice plate report.
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Ladder : FOE range
Oglaend FOE open Ladder specification - connecting length to fitting
FOE straight lengths require splice connector for straight to fitting FOE straight lengths require splice connector for straight to fitting connections
– When connecting a straight to a fitting, two splice plates are generated.g
– The splice plates are not modeled or detailed in the SP3D parts list but are controlled by a specification level rule and will appear on a splice plate report.
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Ladder : FOE range
Oglaend FOE open Ladder specification - connecting fitting to fitting
FOE fittings require a splice connector for straight to fitting FOE fittings require a splice connector for straight to fitting connections
– When connecting a fitting to a fitting, two splice plates are generated.generated.
– The splice plates are not modeled or detailed in the SP3D parts list but are controlled by a specification level rule and will appear on a splice plate report.
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Ladder : FOE range
The specification is designed to place Oglaend fittings in both manual and sketch modes
Oglaend FOE open Ladder specification – Flat Bends
in both manual and sketch modes
Flat bends have fixed angles of 45/90deg
B d il bl i 300 di Bends are available in 300mm radius
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Ladder : FOE range
Oglaend FOE open Ladder specification– Inside or Outside Risers
The specification is designed to place Oglaend fittings in both manual and sketch modesp g p g g
Flexi Risers have variable angles and can be used for 30/45/60/90’. Number of segments may differ per angle & radius.
Riser Radius 400, 600, 800mm available. Riser radius should set prior to placementRiser Radius 400, 600, 800mm available. Riser radius should set prior to placement Flexi Risers should be placed manually to ensure correct selection
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Ladder : FOE range
The specification is designed to place Oglaend fittings in both manual and sketch modes
Oglaend FOE open Ladder specification – Equal Tees
Fixed Tees are available in 300mm radius.
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Ladder : FOE range
Oglaend FOE open Ladder specification– Left Hand & Right Hand and Central Reducers
The specification is designed to manually place Oglaend offset reducer fittings manually.Standard and plate type (part) reducers are available Central Reducers can be placed Automatically or manually
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
Offset Reducer Central Reducer Reducer Part
SP3D : Oglaend Catalogue : Ladder : FOE range
The specification is designed to manually place Oglaend Cross fittings. Automatic placement is not valid.A il bl i 300 di
Oglaend FOE open Ladder specification– Equal Crosses
Available in 300mm radius.
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Ladder : LOE range
Oglaend LOE-55, 75, 100 Ladder specification (Medium \ Light Duty System )
Side rail height : 55mm 75mm 100mm Side rail height : 55mm, 75mm, 100mm Available cabling space : 24mm, 46mm, 68mm Available widths : 200, 300, 400, 500, 600mm
S li d t d d i 3 t l th Supplied as standard in 3 meter lengths Connections by splice plate
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Ladder : LOE range
Oglaend open Ladder specification
The specification is designed to place LOE fittings in both manual and sketch modesp g p g
Understanding of the specification is imperative to efficient construction and material purchaseF lli i i Falling into two remits :
– Sketch mode : being the most effective manner to place– Manual mode : used in restricted environments allowing manual modification and
selection of individual fittingsselection of individual fittings
– Note the following information for LOE specifications :100mm must be added to the straight length to accommodate fitting to straight g g g gjoints. This is to allow for the straight insertion depth when a straight is connected to a Tee, Flat Bend or Cross. For example, a straight length between two flat bends means a total of 200mm being added to the straight length
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
being added to the straight length.
SP3D : Oglaend Catalogue : Ladder : LOE range
Oglaend LOE open Ladder specification
Designed around a series of specifications :By Material &Height
Cableway selection of Oglaend Specifications
– By Material &Height• OGD_LOE_HDG_ Hot dipped galvanized• OGD_LOE_SS Stainless steel• OGD_LOE-PG_ Pre-galvanized
Selection of Specifications with routing Command
Materials to be loaded are specified in the load file Allocation of Usable Cable Space, defined by specification
L d Wid h & D hLoad Width & Depth
Selection Radius with routing Command
Selection of width’s and radius during Placement
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Ladder : LOE range
Oglaend LOE open Ladder specification - connecting length to length
LOE straight lengths require splice connector for straight to Straight connections
– when connecting a straight to a straight, two splice plates are g g g , p pgenerated.
– The splice plates are not modeled or detailed in the SP3D parts list but are controlled by a specification level rule and will appear
li lon a splice plate report.
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Ladder : LOE range
Oglaend LOE open Ladder specification - connecting length to fitting
LOE straight lengths require splice connector for straight to fitting LOE straight lengths require splice connector for straight to fitting connections
– When connecting a straight to a fitting, no splice plate is generated as the fitting is already delivered with a splice plate.g g y p p
– The splice plates are not modeled or detailed in the SP3D parts list but are controlled by a specification level rule and will appear on a splice plate report.
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Ladder : LOE range
Oglaend LOE open Ladder specification - connecting fitting to fitting
LOE fittings require a splice connector for straight to fitting LOE fittings require a splice connector for straight to fitting connections
– When connecting a fitting to a fitting, two splice plate are generated as each fitting is supplied with the required numbergenerated as each fitting is supplied with the required number splices by Oglaend.
– The splice plates are not modeled or detailed in the SP3D parts list but are controlled by a specification level rule and will appear on a splice plate report.
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Ladder : LOE range
The specification is designed to place Oglaend fittings in both manual and sketch modes
Oglaend LOE open Ladder specification – Flat Bends
in both manual and sketch modes
Flat bends are available in 90deg angles
B d il bl ith 300 di Bends are available with 300mm radius
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Ladder : LOE range
Oglaend LOE open Ladder specification– Inside or Outside Risers
The specification is designed to place Oglaend fittings in both manual and sketch modesp g p g g Risers are available for 45 and 90deg bends. LOE 50 has 45deg Riser brackets. LOE 100 has Combi Risers for 45 and 90deg bends
Riser Bracket Combi Riser
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Ladder : LOE range
The specification is designed to place Oglaend fittings in both manual and sketch modes
Oglaend LOE open Ladder specification – Equal Tees
Fixed Tees are available in 300mm radius.
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Ladder : LOE range
The specification is designed to manually place Oglaend Cross fittings. Automatic placement is not valid.A il bl i 300 di
Oglaend LOE open Ladder specification– Equal Crosses
Available in 300mm radius.
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Tray : FTE range
Oglaend FTE-50, 80 Tray specification
Side rail height : 50mm 80mm Side rail height : 50mm, 80mm Available cabling space : 47mm, 77mm Available widths : 50, 100, 150, 200, 300, 400mm
S li d t d d i 3 t l th Supplied as standard in 3 meter lengths Connections by splice plate
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Tray : FTE range
Oglaend open Ladder specification
The specification is designed to place FTE fittings in both manual and sketch modes
Understanding of the specification is imperative to efficient construction and material hpurchase
Falling into two remits :
– Sketch mode : being the most effective manner to place– Sketch mode : being the most effective manner to place– Manual mode : used in restricted environments allowing manual modification and
selection of individual fittings
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Tray : FTE range
Oglaend FTE open Ladder specification
Designed around a series of specifications :By Material &Height
Cableway selection of Oglaend Specifications
– By Material &Height• OGD_FTE_C2 Polyester class 2• OGD_FTE_C1 Polyester class 1
Selection of Specifications with routing Command
Materials to be loaded are specified in the load file Allocation of Usable Cable Space, defined by specification
L d Wid h & D hLoad Width & Depth
Selection Radius with routing Command
Selection of width’s and radius during Placement
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Tray : FTE range
Oglaend FTE open Ladder specification - connecting length to length
FTE straight lengths require splice connector for straight to Straight FTE straight lengths require splice connector for straight to Straight connections
– when connecting a straight to a straight, two splice plates are generated.g
– The splice plates are not modeled or detailed in the SP3D parts list but are controlled by a specification level rule and will appear on a splice plate report.
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Tray : FTE range
Oglaend FTE open Ladder specification - connecting length to fitting
FTE straight lengths require splice connector for straight to fitting FTE straight lengths require splice connector for straight to fitting connections
– When connecting a straight to a fitting, one splice plate is generated as the fitting is already delivered with a splice plate.g g y p p
– The splice plates are not modeled or detailed in the SP3D parts list but are controlled by a specification level rule and will appear on a splice plate report.
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Tray : FTE range
Oglaend FTE open Ladder specification - connecting fitting to fitting
FTE fittings require a splice connector for straight to fitting FTE fittings require a splice connector for straight to fitting connections
– When connecting a fitting to a fitting, no splice plate is generated as each fitting is supplied with the required number splices byas each fitting is supplied with the required number splices by Oglaend.
– The splice plates are not modeled or detailed in the SP3D parts list but are controlled by a specification level rule and will appear on a splice plate report.
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Tray : FTE range
The specification is designed to place Oglaend fittings in both manual and sketch modes
Oglaend FTE open Tray specification – Flat Bends
in both manual and sketch modes
Flat bends have fixed angles of 45 and 90deg
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Tray : FTE range
Oglaend FTE open Tray specification– Inside or Outside Risers
The specification is designed to place Oglaend fittings in both manual and sketch modesRi h fi d l f 45 d 90d Risers have fixed angles of 45 and 90deg.
45deg Risers are Splice Angles. 90deg Risers are Combi Risers.
Splice Angle 45degCombi Riser
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Tray : FTE range
The specification is designed to place Oglaend Tee fittings in both manual and sketch modes
Oglaend FTE open Tray specification – Equal Tee’s
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Ladder : FTE range
Oglaend FTE open Ladder specification– Left & Right Hand Simple Reducers
The specification is designed to manually place Oglaend offset reducer fittings. Automatic placement is not valid.
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
Left Hand ReducerRight Hand Reducer
SP3D : Oglaend Catalogue : Tray : SPB range
Oglaend SPB-20, 40, SPB-RF Tray specification
Side rail height : 20mm 40mm Side rail height : 20mm, 40mm Available cabling space : 18mm, 18.5mm, 38.5mm Available widths : 50, 100, 150, 200, 300, 400, 500, 600mm – SPB-20
A il bl idth 50 100 150 200 300 400 SPB 40 Available widths : 50, 100, 150, 200, 300, 400mm – SPB-40 Available widths : 50, 100, 150, 200, 300, 400, 500, 600mm – SPB-RF Supplied as standard in 3 meter lengths
C ti b li l t Connections by splice plate
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Tray : SPB range
Oglaend open Ladder specification
The specification is designed to place SPB fittings in both manual and sketch modes
Understanding of the specification is imperative to efficient construction and material hpurchase
Falling into two remits :
– Sketch mode : being the most effective manner to place– Sketch mode : being the most effective manner to place– Manual mode : used in restricted environments allowing manual modification and
selection of individual fittings– Note the following information for SPB specifications :g
55mm must be added to the straight length to accommodate fitting to straight joints. This is to allow for the straight insertion depth when a straight is connected to a Tee, Flat Bend or Cross. For example a straight length between two flat bends means a total of 110mm
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
For example, a straight length between two flat bends means a total of 110mm being added to the straight length.
SP3D : Oglaend Catalogue : Tray : SPB range
Oglaend SPB open Ladder specification
Designed around a series of specifications :B M i l &H i h
Cableway selection of Oglaend Specifications
– By Material &Height• OGD_SPB_HDG_ Hot dipped galvanized• OGD_SPB_SS Stainless steel• OGD_SPB_PG Pre-Galvanized (straights only)• OGD SPB-RF HDG Hot dipped galvanized Selection of Specifications with routing Command_ _ _ pp g• OGD_SPB-RF_SS Stainless steel
Materials to be loaded are specified in the load file Allocation of Usable Cable Space, defined by specification
Load Width & Depth
Selection Radius with routing Command
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
Selection of width’s and radius during Placement
SP3D : Oglaend Catalogue : Tray : SPB range
Oglaend SPB open Ladder specification - connecting Straight to Straight SPB straight lengths require splice connector for straight to Straight
connectionsconnections – when connecting a straight to a straight, two splice plates are generated.– The splice plates are not modeled or detailed in the SP3D parts list but are
controlled by a specification level rule and will appear on a splice plate y p pp p preport.
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Tray : SPB range
Oglaend SPB open Ladder specification - connecting Straight to fitting
SPBE straight lengths require splice connector for straight to fitting SPBE straight lengths require splice connector for straight to fitting connections
– When connecting a straight to a fitting, one splice plate is generated as the fitting is already delivered with a splice plate.g y p p
– The splice plates are not modeled or detailed in the SP3D parts list but are controlled by a specification level rule and will appear on a splice plate report.
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Tray : SPB range
Oglaend SPBE open Ladder specification - connecting fitting to fitting
SPB fittings require a splice connector for straight to fitting connections SPB fittings require a splice connector for straight to fitting connections – When connecting a fitting to a fitting, no splice plate is generated as
each fitting is supplied with the required number splices by Oglaend.The splice plates are not modeled or detailed in the SP3D parts list but– The splice plates are not modeled or detailed in the SP3D parts list but are controlled by a specification level rule and will appear on a splice plate report.
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Tray : SPB range
The specification is designed to place Oglaend fittings in both manual and sketch modes
Oglaend SPB open Ladder specification – Flat Bends
in both manual and sketch modes
Flat bends have fixed angles of 45/90deg Flexi Bends can be used for 30/45/90deg angles
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Tray : SPB range
Oglaend SPB open Ladder specification– Inside or Outside Risers
The specification is designed to place Oglaend fittings in both manual and sketch modes
Flexi Risers have variable angles and can be used for 30/45/90deg Flexi Risers should be placed manually to ensure correct selection
Flexi Riser Flexi Risers should be placed manually to ensure correct selection
Combi Risers are available for 90deg vertical bends
Riser
Combi Riser
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Tray : SPB range
The specification is designed to place Oglaend fittings in both manual and sketch modes
Oglaend SPB open Ladder specification – Equal Tees
manual and sketch modes
Tees are available with a 75mm radius.
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Tray : SPB range
Oglaend SPB open Ladder specification– Central Left and Right Hand Reducers
The specification is designed to manually place Oglaend central and offset reducer fittings. Automatic placement of offset reducers is not valid.
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
Left Hand Reducer Central Reducer
SP3D : Oglaend Catalogue : Reporting
Oglaend Cable Ladder & Tray SP3D Specification - Reporting
3 Reports supplied:
Oglaend Fittings Reportg g pOglaend Cover ReportOglaend Splice Report
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D representation
SP3D : Oglaend Catalogue : Reporting
Oglaend Ladder and Tray reporting from SP3DOpen SP3DSelect> Tools > Run reportsp
Note: Reports can also be run from the Drawings and Reports Task
Select > Your system Select> OK
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Reporting
Output format: Excel spread Sheet
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Setup
Oglaend Cable Ladder & Tray SP3D Specification - Set up
SP3D
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D representation
SP3D : Oglaend Catalogue : Setup
Loading SP3D Specifications
Process Stages:Process Stages:
Creating SP3D Catalogue (optional for existing project ) Loading SP3D symbols Project Creation (Optional not covered in document) Updating the Catalogue with the particular specification files
R l ti S ifi ti t SP3D t Relating Specification to SP3D systems
Setting up delivered reports
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Setup
Supplied data directories :
Oglaend Final Deliverables
\SmartPlant
\FOE Final Deliverable (Contains FOE specifications, code lists and custom symbols)
\FTE Final Deliverable (Contains FTE specifications , code lists and custom symbols)
\LOE Final Deliverable (Contains LOE specifications, code lists and custom symbols)
\OE Final Deliverable (Contains OE specifications , code lists and custom symbols)\OE Final Deliverable (Contains OE specifications , code lists and custom symbols)
\SPBE Final Deliverable (Contains SPBE specifications, code lists and custom symbols)
\Reports (Contains Custom report templates and DLL)
\PPTS (General overview of use and how to load)
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Setup
Loading SP3D specification
Please consider the following before loading Oglaend specifications:g g g p
Loading into clean specification catalog Means only the new specification loaded for Oglaend can be used
• Use only specifications for project• Avoids causal users selecting an incorrect Specifications
– Loading into clean database takes time but will not include other disciplines - piping, structural etc– Recommend you load into standard database and just remove additionally supplies specifications– Recommend you load into standard database and just remove additionally supplies specifications
Using and existing specificationNormal to use for change from one specification to another– Normal to use for change from one specification to another
• Allows change from existing specification to another
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Setup
Creating SP3D catalogue
Building your SP3D reference databaseSelect > SP3D PROJECT MANAGERSelect > Database > New > catalogSelect > Database > New > catalogEnter your data :
Catalogue name : OGD_cdb (or whatever you prefer)(recommend that you add _CDB at the end)
Catalogue schema name : ensure this is unique in your database
Template file : point to your default template supplied “Apprepos.dat” for clean or
“Catalogue.dat” for standard product (best option)
Database Templates will be found in the 3dRef product directory
SharedContent Folder
(Do not use product directories for working project)(Do not use product directories for working project)
Normal SP3d Administrator function Associate your catalog to the SmartPlant 3d Project.
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Setup
Creating SP3D loading specification - Obtaining the latest symbols
O Y t tOpen Your ecustomer account:
Select > Software downloads > ProductsSelect > SmartPlant 3DSelect > SmartPlant Enterprise Content for SmartPlant 3DSelect > software version - choose version – Strongly recommended is version 2011 R1 and aboveSelect > Cable tray
Save to the Symbol directory and following next instructions.
Note. Ecustomer is upgraded monthly
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Setup
Creating SP3D loading specification
Before loading the specification the custom symbols must betransferred to the plant catalogues sharedContent folder.
Copy : Symbol IconsFOE Final Deliverable\Symbols\Symbol Icon's
To \ SharedContent\SymbolIcons\
AND : symbols dll’s
FOE Final Deliverable\Symbols\Symbol DllTo
\SharedContent\Custom Symbols
Repeat this procedure for the other specifications in this delivery.Ie
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
OE Final Deliverable
SP3D : Oglaend Catalogue : Setup
Creating SP3D loading specification
Registration of the new symbols:
Open SP3D Project managerSelect > Reference Data (then the plants Catalog )Select > Tools > Update Custom Symbol Configuration.
NoteDo not move on to next step if this has not been completed
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Setup
Creating SP3D loading specification
With starting specification catalogue or Clean catalogue with previous screen completed Or Working catalogueBulk load Specifications
Open Intergraph SmartPlant 3dOpen Intergraph SmartPlant 3d >Database Tools>Bulk load reference data You can find these file in the following directories :
Specification\Data\Part Data or Specification\Data\Codelist
File Type File name Required Load Function
Excel Code list Allcodelists-FOE
Required by Spec. Manufacture, material, span
Excel Code list CableTraySelect Lists
Required by Spec. Cable Part Data Basis
Excel (Spec) Only load the specifications you
i
Oglaend_FOE-2011
Required by Spec. Delivered spec and fittings
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
require.
SP3D : Oglaend Catalogue : Setup
Creating SP3D loading specification
Reviewing you log files;
It is always important to check your log file after the load process : you should expect to see some warning messages relating to items existing this is due to the system telling you that item in the code list exist already these are not of concern:
– Expect
WARNING: cannot create object . Object already exists in the database .SkippedWARNING: cannot create object . Object already exists in the database .Skipped– This is normally and relates to “class node” or Part Class where the each a part will try to create even
though all items require this and it has been created previously. Exists or created is acceptable
– Items to watch for :
• WARNING : Failed to set the Symbol Icon property. gif file is missingThe icon and symbol “dll” where not loaded and update :- contact local Intergraph Support
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Setup
Systems & SpecificationsOpen SP3D : Select > Task > Systems & SpecificationsSelect > Highest level ( Oglaend)Select > Define allowed specification
Select > Specifications to relate to electrical systems
Note. These may be removed / sub selected at the system Level.
Loading all specifications on previous selection adds lost of parts to the database and should be avoided if not required
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
SP3D : Oglaend Catalogue : Setup
The setup of the SP3D Oglaend reports consist of four main steps:
Loading SP3D Oglaend Custom SP3D reports
1, Copying of the Ogleand Report Templates to the catalog SharedContent Reports folder.
2, Bulkloading the supplied Reports workbook. This contains the Oglaend custom report definitions.
3 Creation of 3 Catalog Report filters3, Creation of 3 Catalog Report filters Oglaend Fittings Oglaend Cover PartsOglaend Splice Parts
4 R i t ti f th t R t DLL4, Registration of the custom Report DLL
This process is detailed in the supplied Report Setup document which is found in the Oglaend Final Deliverables\Reports folder
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
I t ti th Integrating the Engineering Engineering Enterprise…
© 2012. Intergraph Process, Power & Marine. All Rights Reserved.
Process, Power and Marine Division
F i f ti i th UK t tFor more information in the UK contact:
Telephone : 01793-619999
Fax : 01793-492975
Web : www.intergraph.co.uk
www.oglaend-system.com